36C25519R0057-0003000.docx
DOCX document 481 KB Posted
- Attached to
- Renovate 5 th Floor, Project No. 589A4-18-187 Renovate Vacated Dental Space, Project NO 589A4-18-102
- Solicitation number
- 36C25519R0057
About this file
36C25519R0057 0003 36C25519R0057 0003.docx
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25519R0057-0004001.pdf | ||
| 36C25519R0057-0004000.docx | DOCX document | |
| 36C25519R0057-0003001.pdf | ||
| 36C25519R0057-0002002.pdf | ||
| 36C25519R0057-0002001.pdf | ||
| 36C25519R0057-0002003.pdf | ||
| 36C25519R0057-0002000.docx | DOCX document | |
| 36C25519R0057-0001005.pdf | ||
| 36C25519R0057-0001007.pdf | ||
| 36C25519R0057-0001004.pdf | ||
| 36C25519R0057-0001003.pdf | ||
| 36C25519R0057-0001002.pdf | ||
| 36C25519R0057-0001006.pdf | ||
| 36C25519R0057-0001000.docx | DOCX document | |
| 36C25519R0057-0001001.pdf | ||
| 36C25519R0057-009.pdf | ||
| 36C25519R0057-003.pdf | ||
| 36C25519R0057-008.pdf | ||
| 36C25519R0057-010.pdf | ||
| 36C25519R0057-011.pdf | ||
| 36C25519R0057-002.pdf | ||
| 36C25519R0057-006.pdf | ||
| 36C25519R0057-012.pdf | ||
| 36C25519R0057-004.pdf | ||
| 36C25519R0057-005.pdf | ||
| 36C25519R0057-007.pdf | ||
| 36C25519R0057-001.docx | DOCX document | |
| 36C25519R0057-000.docx | DOCX document |
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
5. PROJECT NUMBER (if applicable)
CODE
7. ADMINISTERED BY
2. AMENDMENT/MODIFICATION NUMBER
CODE
6. ISSUED BY
8. NAME AND ADDRESS OF CONTRACTOR
4. REQUISITION/PURCHASE REQ. NUMBER
3. EFFECTIVE DATE
9A. AMENDMENT OF SOLICITATION NUMBER
9B. DATED
PAGE OF PAGES
10A. MODIFICATION OF CONTRACT/ORDER NUMBER
10B. DATED
BPA NO.
1. CONTRACT ID CODE
FACILITY CODE
CODE
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers
E. IMPORTANT:
is extended,
(a) By completing Items 8 and 15, and returning __________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY is not extended.
12. ACCOUNTING AND APPROPRIATION DATA
(REV. 11/2016)
is required to sign this document and return ___________ copies to the issuing office.
is not, A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.
15C. DATE SIGNED
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER
Contractor
16C. DATE SIGNED
14. DESCRIPTION OF AMENDMENT/MODIFICATION
16B. UNITED STATES OF AMERICA
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER
16A. NAME AND TITLE OF CONTRACTING OFFICER
15B. CONTRACTOR/OFFEROR
STANDARD FORM 30
PREVIOUS EDITION NOT USABLE
Prescribed by GSA - FAR (48 CFR) 53.243 (Type or print) (Type or print) (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
(Number, street, county, State and ZIP Code) (If other than Item 6) (Specify type of modification and authority) (such as changes in paying office, appropriation date, etc.)
(If required)
(SEE ITEM 11)
(SEE ITEM 13)
(X)
CHECK
ONE
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
(Signature of person authorized to sign) (Signature of Contracting Officer) 06-14-2019 589A4-18-187 36C255 Department of Veterans Affairs Network Contracting Office (NCO) 15 3450 S 4th Street Trafficway Leavenworth
KS
66048 36C255 Department of Veterans Affairs Network Contracting Office (NCO) 15 3450 S 4th Street Trafficway Leavenworth
KS
66048 To all Offerors/Bidders
36C25519R0057 06-11-2019
X X X
June 26, 2019 by 2:00 PM CDT Remodel 5th Floor, 589A4-18-187 and Renovate Vacated Dental Space 589A4-18-102
a. This amendment provides the following: additional questions and answers for both projects, revised Drawing for Remodel 5th floor that were identified on Amendment 2.
revised BID item sheet that replaces bid item fill-in on SF1442 page 2 and revised Appendix 2 Contractor Certification Regarding Safety and Environmental.
b.This Amendment extends the closing date for proposals to June 26, 2019 by 2:00 pm CDT
c. All other terms and conditions are unchanged
CONTINUATION PAGE
BID ITEMS
BID ITEM #1: RENOVATE VACATED DENTAL SPACE: includes all scope communicated in the drawings and specifications which includes the complete renovation of the first-floor former dental space. The scope of work involves hazardous materials abatement and selective interior demolition.
BID ITEM #2: REMODEL 5TH FLOOR: includes all scope communicated in the drawings and specifications which includes the complete renovation of the fifth floor. The scope of work involves hazardous materials abatement and selective interior demolition.
BID ITEMS 3-5 are ABATEMENT UNIT PRICING
C. BID ITEM #3: UNIT PRICING-Provide abatement unit price per insulation fitting of 6” or less diameter. This will be used for possible modification as required for additional fittings beyond what is specified or for credit if specified amount is not required. This unit pricing applies to both “Renovate Vacated Dental Space” and “Remodel 5th Floor”. See revised General Specification provided in Amendment 2 for further information.
BID ITEM #4: UNIT PRICING-Provide abatement unit price per insulation fitting greater than 6” diameter. This will be used for possible modification as required for additional fittings beyond what is specified or for credit if specified amount is not required. This unit pricing applies to both “Renovate Vacated Dental Space” and “Remodel 5th Floor”. See revised General Specification provided in Amendment 2 for further information.
E. BID ITEM #5: Provide abatement unit price per square feet of flooring and mastic. This will be used for possible modification as required for additional fittings beyond what is specified or for credit if specified amount is not required. This unit pricing applies to both “Renovate Vacated Dental Space” and “Remodel 5th Floor”. See revised General Specification provided in Amendment 2 for further information.
APPENDIX 2 - Pre-Award Contractor Safety and Environmental Record Evaluation Form
Information provided below is current and applicable to Solicitation VA255-17-R-0057:
Company Name: ______________________________________________ Address: _____________________________________________________ Telephone: ______________________ Fax: ________________________ Email: _______________________________________________________ Contact: ______________________________________________________
1. Utilizing your OSHA 300 Forms, please complete the following information:
| Category |
| 2015 |
| 2016 |
| 2017 |
| 2018 |
Number of man hours (jobsite and office).
Number of cases involving days away from work, restricted activity, or both (Column H and I of OSHA 300).
Days away, restricted, or transferred rate (# of days away, restricted, or transferred cases x 200,000/# of man hours) (DART Rate).
Number of serious, willful, or repeat violations from OSHA within the last 3 years. Please attach explanation for any violations.
Please attach copies of the following documents: OSHA 300 and 300a Forms. These forms can be accessed through the OSHA publications search page: http://www.osha.gov/pls/publications/publication.html.
2. Provide six-digit North American Industrial Classification System (NAICS) Code for this acquisition: __________________________________
3. Who administers your company’s Safety and Health Program? ____________________________
4. Company’s Insurance Experience Modification Rate (EMR): ____________________________
| Project Name: | Renovate Vacated Dental Spaces |
| Location: | Columbia, Missouri |
| VA Project #: | 589A4-18-102 |
Additional Questions and Answers
| 5 |
| On Drawing Sheet GI101 Detail 1 it calls for the ceiling removed to be replaced each day due to fire sprinkler concerns. Does this apply to the hard ceilings in this area as well? |
| Answer |
| 1. Contractor is responsible to ensure that fire sprinkler coverage is maintained to fire code, in all construction areas, at all times. |
2. If ceiling cannot be replaced in same shift, the contractor is responsible for modifications to sprinkler system needed to provide sprinkler coverage for the exposed deck/above ceiling equipment, per fire code.
| 6 |
| Appendix 2 Safety document in the solicitation asks for 2019 OSHA300 information. We will not receive this information until early 2020. Please advise that we are only to provide safety information for 2016, 2017, & 2018. |
| Answer |
| 1. See Amendment 3 |
| 7 |
| Can you confirm the Cast-in-Place concrete on this project is limited to the repair of damaged concrete during construction, and the leveling of existing concrete surfaces? |
| Answer |
| 1. Yes the concrete is included to ensure proper concrete for patching of holes. |
2. See General Demo Notes - M
| 8 |
| There does not appear to be any locations for fire extinguishers or fire extinguisher cabinets in the plans. If these items are to be installed on this project can you provide us with locations? |
| Answer |
| 1. See AS101 – Plan Notes – Floor Plan – Notes #7 & #8 |
Additional changes:
Per new life safety updates, change all wall mounted fire alarm audio and audio/visual devices to ceiling mounted devices.
117 Pierce St. Suite 110 Sioux City, Iowa 51101 P
712.252.4014 )Meeting Minutes
Page 1 | 1 Page 1 of Page 2 | 2 Page 1 of Solicitation Additional Questions and Answers
| PROJECT: | REMODEL 5TH FLOOR | |
| PROJECT NO: | 589A4-18-187 | |
| LOCATION: | Harry S. Truman VA Medical Center Conference Room |
QUESTIONS AND ANSWERS
Q9. Is this project tax exempt?
A9. Yes
Q10. Please provide the site visit sign-in sheet.
A10. See Amendment 2
Q11. Can the Superintendent and the Quality Control Manager be one in the same?
A11. Read Proposal Submittal Instructions
Q12. On drawing sheet AE401, please confirm the Free-Standing Ice machine (R4650) is contractor provided and contractor installed. If so, please provide a basis of design.
A12. Contractor purchase and install. Basis of design: Follett, 25FB425A-S 25 Series Air Cooled Freestanding Ice and Water Dispenser
Q13. On drawing sheet AE401, please confirm the Refrigerator (R7000) is contractor provided and contractor installed. If so, please provide a basis of design.
A13. Contractor purchase and install. Basis of design: Insignia, NS-RTM18SS7, 18 cf top mount refrigerator (no ice maker)
Q14. On drawing sheet AE401, please confirm the Microwave (K4665) is contractor provided and contractor installed. If so, please provide a basis of design.
A14. Contractor purchase and install. Basis of design: Panasonic, NN-SN966SAPH, 2.2 cf microwave oven
Q15. On drawing sheet AE401, please confirm the Television (M0500A) is contractor provided and contractor installed. If so, please provide a basis of design.
A15. Existing television to be relocated by Contractor. Contractor to purchase and install wall mount for 42” monitor.
Q16. On drawing sheet AE401, please confirm the computer (M1801) is contractor provided and contractor installed. If so, please provide a basis of design.
A16. All computers will be provided and installed by VA
Q17. Drawing sheet AE401 lists a dry erase board (F3010) but there is no locations identified on the drawings. Please advise if any are to be provided and installed.
A17. See detail 7/AE401 – Lactation Room. See IN301 – Partition to receive marker board laminate.
Q18. Drawing sheet IN202 detail 2 calls for a new Smart Board to be furnished and installed but no information is provided. If it is to be furnished and installed please specification and basis of design.
A18. Contractor to purchase and install. Basis of design: SMART Technologies, SMART Board 7086, 86” Pro series interactive flat panel with SMART Meeting Pro. Include wall mount.
Q19. On drawing sheet IF100, please confirm the Projector (M0385) is contractor provided and contractor installed. If so, please provide a basis of design.
A19. Contractor to purchase and install. Basis of design: Epson America, Powerlite 955WH
Q20. On drawing sheet IF100, please confirm the Projection Screen (M0410) is contractor provided and contractor installed. If so, please provide a basis of design.
A20. Contractor to purchase and install. Basis of design: Dalite 84326LS Advantage Electrol Motorized Front Projection Screen, ceiling recessed.
Q21. On drawing sheet IF100, please confirm the Video Teleconferencing System (M0507) is contractor provided and contractor installed. If so, please provide a basis of design.
A21. Teleconferencing System will be purchased by VA. Contractor will be required to install the equipment.
Q22. Please confirm we are to only provide the physical backbone of the nurse call system to include conduits, back boxes, power, etc. The VA will directly contract with the nurse call system provider for the installation of the system.
A22. Nurse Call to be purchased and installed by Contractor.
Q23. Please confirm we are to install the VA provide patient lift (Z-4) shown on drawing sheet AE401.
A23. Contractor to work with Guldmann to relocate existing patient lift.
Q24. Please advise if the operable partition between Classroom 545 and Classroom 550 is to be Modernfold shown on drawing sheet IN101 or Skyfold shown on Detail 5 on drawing sheet AE512 and specification section 10 22 26.
A24. Skyfold.
Q25. Please advise if door frame for door number 511 and 515 should be frame type 2 instead of frame type 1.
A25. These two doors should be Type 1. Type 2 is for egress door.
Q26. Please provide any structural modifications, plans and details needed for the patient lift.
A26. Patient lift vendor/installer to provide shop drawings with contractor submittal.
Q27. Please provide the 4th existing architectural, structural and MEP floor plan drawings to include the plenum space to determine the impacts to the space during the 5th floor remodel.
A27. See attached 4th floor layout.
Q28. Will any work in the 4th floor plenum need to be performed on weekends and/or afterhours?
A28. All work to be coordinated with COR, some work to occur afterhours/on weekends.
Q29. On drawings PD100 and PD102 there is a note referencing removal of an existing sprinkler riser. Please confirm if this is an active or abandoned sprinkler riser.
A29. Existing sprinkler riser is abandoned.
Q30. Is there only 1 vertical wall and no regular folding panel partitions?
A30. See attached revised sheets AE101, AE102 and AE103 keynote 1 for location of detail 5/AE512 Skyfold partition.
Q31. Is there a form for a substitution request? We would like to submit the Hufcor Summit vertical wall as an option.
A31. To propose a substitution, the item must meet or exceed the specifications of the listed item. Please provide with proposal, information showing the proposed substitution meets or exceeds specifications.
Q32. Are they looking at full panel markerboards on all panels?
A32. Yes.
Q33. Is there a bidders list?
A33. See Amendment 2
Q34. Per the specs we are to tie into the current fire alarm control unit. Do you know what the current fire alarm system is?
A34. Per new life safety upgrades, change all wall mounted fire alarm audio and audio/visual devices to ceiling mounted devices.
Additional changes:
Per new life safety updates, change all wall mounted fire alarm audio and audio/visual devices to ceiling mounted devices.
Attachments: Revised sheets AE101, AE102, AE103.
( Specification section 01 00 00 General Requirements provided in Amendment 2.)
A.1 List of Attachments
See attached document: Revised Drawings-5th Floor.