Text version

UP

ROOF

OF

FIRST

FLOOR

ROOF

OF

FIRST

FLOOR

DN

UP

DN

UP

4 4

4 3 3

3 4 4

4 4

4 3 4 4 3 4 3

4 3 4 3

3 3

2 2

2 2 2 2

2 2

5 5 5 5 5 5 5

5 5

888888888888888

8 8

888 8

NOT IN

SCOPE OF

WORK

NOT IN

SCOPE OF

WORK

NOT IN

SCOPE OF

WORK

NOT IN

SCOPE OF

WORK

ALSO REF. MEP DRAWINGS FOR

SCOPE OF DEMOLITION.

12 12

PROTECT EXISTING STRUCTURE

FROM DAMAGE. TYPICAL FOR ALL

LOCATIONS.

NOT IN

SCOPE OF

WORK

EXIST. TELECOM CLOSET TO REMAIN

WALL

DOOR

CEILING

AND GRID

DEMO LEGEND

CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO WORK BEGINNING.

THE CONTRACTOR IS RESPONSIBLE FOR INFORMING THE COR OF ANY CONDITIONS

THAT DIFFER FROM THE INFORMATION INDICATED IN THE DRAWINGS.

A.

GENERAL DEMOLITION NOTES:

PROTECT ALL EXISTING BUILDING COMPONENTS WHICH ARE TO REMAIN. REPAIR ANY

DAMAGED AREAS AS REQUIRED TO RETURN THEM TO THEIR ORIGINAL CONDITION.

B.

VERIFY EXTENT OF DEMOLITION WORK WITH INFORMATION SHOWN IN THE

DRAWINGS, AND WORK THAT IS NOT SHOWN AND MAY BE REQUIRED TO COMPLETE

THE INTENDED WORK.

C.

ALL WORK SHALL COMPLY WITH REQUIRED LOCAL CODES. CONTRACTOR IS

RESPONSIBLE FOR OBTAINING REQUIRED PERMITS AND INSPECTIONS FOR ALL

WORK ASSOCIATED WITH THIS CONTRACT.

D.

CONTRACTOR SHALL REPAIR ALL DISTURBED AREAS AS REQUIRED TO MATCH

SURROUNDING EXISTING FINISHES NOT DISTURBED.

E.

TYPES OF FLOOR, WALL, AND CEILING FINISHES INDICATED FOR REMOVAL BY

DEMOLITION NOTES IS FOR GENERAL INFORMATION ONLY FROM INFORMATION OBTAINED

FROM EXISTING PLANS AND OBSERVATIONS. CONTRACTOR SHALL FIELD VERIFY

MATERIAL TYPES ONSITE PRIOR TO BID AND INCLUDE NECESSARY WORK IN HIS BID.

F.

ALL AUTOMATIC DOOR OPERATORS, ACCESS CONTROL & DOOR HARDWARE,

APPLIANCES, FURNITURE, AND EQUIPMENT TO REMAIN THE PROPERTY OF THE

OWNER - CONTRACTOR TO COORDINATE REMOVAL, RELOCATION, STORAGE OF

EQUIPMENT FROM DEMO AREAS WITH OWNER.

G.

PATCH FLOOR AT REMOVED WALLS AND CASEWORK PREPARE FLOOR TO RECEIVE

NEW FLOORING AS REQUIRED.

H.

PATCH ALL HOLES IN EXISTING SLAB LEFT FROM REMOVAL OF FIXTURES.I.

REMOVE ALL WALL PROTECTION CAREFULLY AND RETURN TO OWNER.J.

CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL MATERIAL IN A LEGAL MANNER

NOT SCHEDULED FOR REUSE UNDER THIS PROJECT.

K.

IN ALL WALLS AND CEILINGS THAT ARE TO BE REMOVED THE CONTRACTOR SHALL

BE RESPONSIBLE FOR DISCONNECTING AT SOURCE AND REMOVING OR CAPPING

ELECTRICAL, PLUMBING, GAS LINES AND MECHANICAL DUCTWORK THAT IS

DISCLOSE AND NOT SCHEDULED FOR REUSE. CONTRACTOR SHALL REROUTE AND

CONTINUE ANY SYSTEM THAT MUST BE RETAINED FOR NEW CONSTRUCTION.

L.

ALL ELECTRICAL CIRCUITS FOR EQUIPMENT THAT IS TO BE REMOVED SHALL BE

DISCONNECTED AT SOURCE AND REMOVED.

M.

ALL PIPING GAS, WATER SUPPLY, VENT, DRAIN LINES, ETC. SUPPLYING EQUIPMENT

THAT IS TO BE REMOVED SHALL BE DISCONNECTED, REMOVED AND CAPPED

ABOVE CEILING OR BELOW FLOOR. CONTRACTOR SHALL REROUTE AS NECESSARY,

TO BE BEHIND NEW CONSTRUCTION. (PATCH FLOOR BACK PRIOR TO TOPPING.)

N.

ALL MED GASES AND PLUMBING TO BE REMOVED AT WALLS SCHEDULED FOR

DEMOLITION.

O.

REMOVE ALL PLUMBING FIXTURES AND EQUIPMENT WITHIN ROOMS SCHEDULED TO

BE DEMOLISHED. SEE MEP PIPING DRAWINGS.

P.

RETURN ALL SIGNAGE AFFECTED BY CONSTRUCTION TO OWNER.Q.

CONTRACTOR TO COORDINATE INFECTIOUS CONTROL REQUIREMENTS WITH

OWNER PRIOR TO ANY CONSTRUCTION.

R.

REMOVE ALL WINDOW TREATMENTS AND HARDWARE.S.

REMOVE ALL CUBICLE CURTAINS AND ASSOCIATED TRACKS IN AREAS TO BE REMODELED

AND RETURN TO OWNER.

T.

REMOVE ALL WALL-MOUNTED COMPUTER DESKS, MONITORS, ETC. AND RETAIN

FOR REINSTALLATION PER EQUIPMENT PLANS.

U.

REMOVE ALL AUTOMATIC DOOR OPERATOR HARDWARE WITHIN THE PROJECT

AREA AND RETURN TO THE VA.

V.

PHASE 1 PROJECT

N

KEY PLAN - 2ND FLOOR

1" = 60'-0"

1 1

1 1

1 1 1 1 1 1 1

111111

NOT IN

SCOPE OF

WORK

NOT IN

SCOPE OF

WORK

NOT IN

SCOPE OF

WORK

NOT IN

SCOPE OF

WORK

NOTE:

ALSO REF. MEP DRAWINGS FOR

SCOPE OF DEMOLITION.

NOT IN

SCOPE OF

WORK

SIMULATION

LAB

VISUAL

IMPAIRMENT

SERVICES

OFFICE

RR

STORE

OFFICE

CHAPLAIN

PASTORAL

CARE

OFFICE

CHAPLAIN

OFFICE

STAIRS

ASSOCIATE

DIRECTOR

ICU

RR

NURSE

OFFICE

TELEHEALTH

GUEST

ROOM

RR

GUEST

ROOM

ELEV. CORRIDOR

CORRIDOR

ICU

WAITING

ROOM

SLEEP

RR

HEMODIALYSIS

EXAM

ROOM

HEMODIALYSIS

STORAGE

SPEECH

THERAPY

OFFICE

OFFICEBREAK AND

LOCKER

ROOM

OFFICE

RR

ELEC

EUCHARISTIC

CHAPEL

STORE

CHAPLAIN

OFFICE

CHAPEL

EDUCATION

OFFICE

EDUCATION

OFFICE

OFFICE

EDUCATION

STORAGE

STUDY

ROOM

BREAK

ROOM

STAIRS

STORAGE

STOR

RESPIRATORY

THERAPY

OFFICE

Drawing Title Project Title

Date

Location

Checked

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

589A7-17-203

Robert J. Dole VA Medical Center

RENOVATE WARDS FOR PATIENT

PRIVACY PHASE 1, B1

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA

142 N. MOSELY ST

WICHITA, KANSAS FINAL CONSTRUCTION DOCUMENTS

AD-101

1ST & 2ND FLOOR DEMOLITION

Wichita, Kansas

DCW RMC04-27-2018

1/8" = 1'-0"1

2ND FLOOR - DEMOLITION PLAN

N 4' 8' 16'

1/8" = 1'-0"

0'

DEMO SCHEDULE

1 EXISTING CEILING AND GRID TO BE REMOVED - REFER TO GENERAL DEMOLITION NOTE (N).

INCLUDES DRYWALL AND PLASTER SOFFITS WITHIN CEILING AREAS TO BE DEMOLISHED. ALL

EXISTING CEILINGS WITHIN PROJECT AREA TO BE REMOVED.

2 EXISTING FLOORING TO BE REMOVED - PREPARE AREA FOR NEW FLOOR FINISH. ALL

FLOORING WITHIN PROJECT AREA TO BE REMOVED.

3 EXISTING WALL FINISH AND WALL FURRING TO BE REMOVED - PREPARE AREA FOR NEW WALL

FINISH.

4 EXISTING WALL FINISH TO BE REMOVED - PREPARE AREA FOR NEW WALL FINISH. TYPICAL AT

ALL REMAINING PLASTER WALLS.

5 EXISTING DOOR AND FRAME AND ALL HARDWARE TO BE REMOVED.

6 EXISTING PLUMBING FIXTURE TO BE REMOVED - REFER TO GENERAL DEMOLITION NOTE (P).

7 EXISTING CASEWORK TO BE REMOVED.

8 EXISTING WALL AND ALL OF ITS BUILDING COMPONENTS TO BE REMOVED. (FULL HEIGHT) -

REFER TO GENERAL DEMOLITION NOTE (N).

9 EXISTING TOILET PARTITION AND ALL OF ITS BUILDING COMPONENTS TO BE REMOVED.

10 STAINLESS STEEL COUNTER AND WALL CABINET TO BE RELOCATED.

11 EXISTING DIALYSIS FIXTURES TO BE REMOVED. REFER TO MEP DRAWINGS.

12 EXISTING BASE UNIT HEATER TO BE REMOVED. REFER TO MEP DRAWINGS.

13 EXISTING LOCKER(S) TO BE REMOVED.

14 EXISTING CHAPEL ART GLASS INSIDE WINDOWS TO BE REMOVED. RETURN TO THE VA.

1/8" = 1'-0"2

2ND FLOOR - CEILING DEMOLITION PLAN

N 8' 16' 32'

1/16" = 1'-0"

0'

1/8" = 1'-0"3

1ST FLOOR - DEMOLITION PLAN

N 4' 8' 16'

1/8" = 1'-0"

0'

SEE SPECIFICATION SECTION 01 00 00

FOR FIELD VERIFICATION OF EXISTING

CONCRETE COLUMN, BEAM, AND JOIST LOCATIONS.

No. Description Date

SEE SPECIFICATION SECTION 01 00 00

FOR MANOMETER REQUIREMENTS AT EACH FLOOR

DURING CONSTRUCTION ACTIVITIES.

SEE SPECIFICATION SECTION 01 35 26 FOR

INFECTION CONTROL REQUIREMENTS FOR THIS

PROJECT.

REQUIREMENTS INCLUDE, BUT ARE NOT LIMITED

TO CONSTRUCTION PARTITIONS, NEGATIVE AIR

PRESSURE WITHIN CONSTRUCTION AREAS, AND

PROVISION OF ANTEROOMS AT CONSTRUCTION

ENTRANCES.

DN

4 4

4 4

4 4

4 4

4 3 4 4 4 3

4 3 4

2 2 2

2 2 2

5 5 5 5 5 5 5

5 5

888888888888

88888 8 8

6 6

NOT IN

SCOPE OF

WORK

NOT IN

SCOPE OF

WORK

12 12 12 12

ALSO REF. MEP DRAWINGS FOR

SCOPE OF DEMOLITION.

PROTECT EXISTING STRUCTURE

FROM DAMAGE. TYPICAL FOR ALL

LOCATIONS.

NOT IN

SCOPE OF

WORK

EXIST. TELECOM CLOSET TO REMAIN

131313

WALL

DOOR

CEILING

AND GRID

DEMO LEGEND

PHASE 1 PROJECT

N

KEY PLAN - 3RD FLOOR

1" = 60'-0"

1 1 1

1 1 1 1 1

1 1 1 1 1

NOT IN

SCOPE OF

WORK

NOT IN

SCOPE OF

WORK

NOTE:

ALSO REF. MEP DRAWINGS FOR

SCOPE OF DEMOLITION.

NOT IN

SCOPE OF

WORK

CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO WORK BEGINNING.

THE CONTRACTOR IS RESPONSIBLE FOR INFORMING THE COR OF ANY CONDITIONS

THAT DIFFER FROM THE INFORMATION INDICATED IN THE DRAWINGS.

A.

GENERAL DEMOLITION NOTES:

PROTECT ALL EXISTING BUILDING COMPONENTS WHICH ARE TO REMAIN. REPAIR ANY

DAMAGED AREAS AS REQUIRED TO RETURN THEM TO THEIR ORIGINAL CONDITION.

B.

VERIFY EXTENT OF DEMOLITION WORK WITH INFORMATION SHOWN IN THE

DRAWINGS, AND WORK THAT IS NOT SHOWN AND MAY BE REQUIRED TO COMPLETE

THE INTENDED WORK.

C.

ALL WORK SHALL COMPLY WITH REQUIRED LOCAL CODES. CONTRACTOR IS

RESPONSIBLE FOR OBTAINING REQUIRED PERMITS AND INSPECTIONS FOR ALL

WORK ASSOCIATED WITH THIS CONTRACT.

D.

CONTRACTOR SHALL REPAIR ALL DISTURBED AREAS AS REQUIRED TO MATCH

SURROUNDING EXISTING FINISHES NOT DISTURBED.

E.

TYPES OF FLOOR, WALL, AND CEILING FINISHES INDICATED FOR REMOVAL BY

DEMOLITION NOTES IS FOR GENERAL INFORMATION ONLY FROM INFORMATION OBTAINED

FROM EXISTING PLANS AND OBSERVATIONS. CONTRACTOR SHALL FIELD VERIFY

MATERIAL TYPES ONSITE PRIOR TO BID AND INCLUDE NECESSARY WORK IN HIS BID.

F.

ALL AUTOMATIC DOOR OPERATORS, ACCESS CONTROL & DOOR HARDWARE,

APPLIANCES, FURNITURE, AND EQUIPMENT TO REMAIN THE PROPERTY OF THE

OWNER - CONTRACTOR TO COORDINATE REMOVAL, RELOCATION, STORAGE OF

EQUIPMENT FROM DEMO AREAS WITH OWNER.

G.

PATCH FLOOR AT REMOVED WALLS AND CASEWORK PREPARE FLOOR TO RECEIVE

NEW FLOORING AS REQUIRED.

H.

PATCH ALL HOLES IN EXISTING SLAB LEFT FROM REMOVAL OF FIXTURES.I.

REMOVE ALL WALL PROTECTION CAREFULLY AND RETURN TO OWNER.J.

CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL MATERIAL IN A LEGAL MANNER

NOT SCHEDULED FOR REUSE UNDER THIS PROJECT.

K.

IN ALL WALLS AND CEILINGS THAT ARE TO BE REMOVED THE CONTRACTOR SHALL

BE RESPONSIBLE FOR DISCONNECTING AT SOURCE AND REMOVING OR CAPPING

ELECTRICAL, PLUMBING, GAS LINES AND MECHANICAL DUCTWORK THAT IS

DISCLOSE AND NOT SCHEDULED FOR REUSE. CONTRACTOR SHALL REROUTE AND

CONTINUE ANY SYSTEM THAT MUST BE RETAINED FOR NEW CONSTRUCTION.

L.

ALL ELECTRICAL CIRCUITS FOR EQUIPMENT THAT IS TO BE REMOVED SHALL BE

DISCONNECTED AT SOURCE AND REMOVED.

M.

ALL PIPING GAS, WATER SUPPLY, VENT, DRAIN LINES, ETC. SUPPLYING EQUIPMENT

THAT IS TO BE REMOVED SHALL BE DISCONNECTED, REMOVED AND CAPPED

ABOVE CEILING OR BELOW FLOOR. CONTRACTOR SHALL REROUTE AS NECESSARY,

TO BE BEHIND NEW CONSTRUCTION. (PATCH FLOOR BACK PRIOR TO TOPPING.)

N.

ALL MED GASES AND PLUMBING TO BE REMOVED AT WALLS SCHEDULED FOR

DEMOLITION.

O.

REMOVE ALL PLUMBING FIXTURES AND EQUIPMENT WITHIN ROOMS SCHEDULED TO

BE DEMOLISHED. SEE MEP PIPING DRAWINGS.

P.

RETURN ALL SIGNAGE AFFECTED BY CONSTRUCTION TO OWNER.Q.

CONTRACTOR TO COORDINATE INFECTIOUS CONTROL REQUIREMENTS WITH

OWNER PRIOR TO ANY CONSTRUCTION.

R.

REMOVE ALL WINDOW TREATMENTS AND HARDWARE.S.

REMOVE ALL CUBICLE CURTAINS AND ASSOCIATED TRACKS IN AREAS TO BE REMODELED

AND RETURN TO OWNER.

T.

REMOVE ALL WALL-MOUNTED COMPUTER DESKS, MONITORS, ETC. AND RETAIN

FOR REINSTALLATION PER EQUIPMENT PLANS.

U.

REMOVE ALL AUTOMATIC DOOR OPERATOR HARDWARE WITHIN THE PROJECT

AREA AND RETURN TO THE VA.

V.

PATIENT

ROOM

OBSERVATION

RR

PATIENT

ROOM

PATIENT

ROOM

HSKPG

CLEAN

LINEN

MEDICAL

ROOM 1

RESIDENTS

OFFICE

CORRIDOR

NURSE

OFFICE

STAIRS

PATIENT

ROOM RR

PATIENT

ROOM

STORAGE

PATIENT

ROOM

PATIENT

ROOM

NURSE

STATION

TOILET

TOILET

RR

PATIENT

ROOM

PATIENT

ROOM

PATIENT

ROOM

MEN'S

ELEC

STAFF RR

CLEAN

SUPPLY

SPD

STORAGE PATIENT

ROOM

PATIENT

ROOM

NURSE

OFFICE EMPLOYEE

LOUNGE

EQUIPMENT

STORAGE

RECEPTION

VENDING

ELEV.

LOCKER

ROOM

STAIRS

PATIENT

ROOM

IRM

Drawing Title Project Title

Date

Location

Checked

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

589A7-17-203

Robert J. Dole VA Medical Center

RENOVATE WARDS FOR PATIENT

PRIVACY PHASE 1, B1

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA

142 N. MOSELY ST

WICHITA, KANSAS FINAL CONSTRUCTION DOCUMENTS

AD-102

3RD FLOOR DEMOLITION

Wichita, Kansas

DCW RMC04-27-2018

N 4' 8' 16'

1/8" = 1'-0"

0'

1/8" = 1'-0"1

PARTIAL 3RD FLOOR - DEMOLITION PLAN

1/8" = 1'-0"2

PARTIAL 3RD FLOOR - CEILING DEMOLITION PLAN

N 8' 16' 32'

1/16" = 1'-0"

0'

DEMO SCHEDULE

1 EXISTING CEILING AND GRID TO BE REMOVED - REFER TO GENERAL DEMOLITION NOTE (N).

INCLUDES DRYWALL AND PLASTER SOFFITS WITHIN CEILING AREAS TO BE DEMOLISHED. ALL

EXISTING CEILINGS WITHIN PROJECT AREA TO BE REMOVED.

2 EXISTING FLOORING TO BE REMOVED - PREPARE AREA FOR NEW FLOOR FINISH. ALL

FLOORING WITHIN PROJECT AREA TO BE REMOVED.

3 EXISTING WALL FINISH AND WALL FURRING TO BE REMOVED - PREPARE AREA FOR NEW WALL

FINISH.

4 EXISTING WALL FINISH TO BE REMOVED - PREPARE AREA FOR NEW WALL FINISH. TYPICAL AT

ALL REMAINING PLASTER WALLS.

5 EXISTING DOOR AND FRAME AND ALL HARDWARE TO BE REMOVED.

6 EXISTING PLUMBING FIXTURE TO BE REMOVED - REFER TO GENERAL DEMOLITION NOTE (P).

7 EXISTING CASEWORK TO BE REMOVED.

8 EXISTING WALL AND ALL OF ITS BUILDING COMPONENTS TO BE REMOVED. (FULL HEIGHT) -

REFER TO GENERAL DEMOLITION NOTE (N).

9 EXISTING TOILET PARTITION AND ALL OF ITS BUILDING COMPONENTS TO BE REMOVED.

10 STAINLESS STEEL COUNTER AND WALL CABINET TO BE RELOCATED.

11 EXISTING DIALYSIS FIXTURES TO BE REMOVED. REFER TO MEP DRAWINGS.

12 EXISTING BASE UNIT HEATER TO BE REMOVED. REFER TO MEP DRAWINGS.

13 EXISTING LOCKER(S) TO BE REMOVED.

14 EXISTING CHAPEL ART GLASS INSIDE WINDOWS TO BE REMOVED. RETURN TO THE VA.

SEE SPECIFICATION SECTION 01 00 00

FOR FIELD VERIFICATION OF EXISTING

CONCRETE COLUMN, BEAM, AND JOIST LOCATIONS.

No. Description Date

SEE SPECIFICATION SECTION 01 00 00

FOR MANOMETER REQUIREMENTS AT EACH FLOOR

DURING CONSTRUCTION ACTIVITIES.

SEE SPECIFICATION SECTION 01 35 26 FOR

INFECTION CONTROL REQUIREMENTS FOR THIS

PROJECT.

REQUIREMENTS INCLUDE, BUT ARE NOT LIMITED

TO CONSTRUCTION PARTITIONS, NEGATIVE AIR

PRESSURE WITHIN CONSTRUCTION AREAS, AND

NOT IN

SCOPE OF

WORK

NOT IN

SCOPE OF

WORK

ALSO REF. MEP DRAWINGS FOR

SCOPE OF DEMOLITION.

PROTECT EXISTING STRUCTURE

FROM DAMAGE. TYPICAL FOR ALL

LOCATIONS.

THIS SHADED AREA REPRESENTS THE APPROXIMATE

AREA TO BE PRESERVED IN THIS BID ITEM (PORTIONS OF

2 PATIENT ROOMS, 2 TOILET ROOMS AND A PORTION

OF THE ROOM TO THE NORTH.)

SEE SPECIFICATIONS AND ALSO NARRATIVE ON G-105.

NOT IN

SCOPE OF

WORK

SEE BID ITEM 1 FOR DEMOLITION

NOTES FOR THIS AREA (UN-SHADED)

SEE BID ITEM 1 FOR DEMOLITION

NOTES FOR THIS AREA (UN-SHADED)

BID ITEM 3 - AREAS AFFECTED

NOT IN

SCOPE OF

WORK

NOT IN

SCOPE OF

WORK

NOTE:

ALSO REF. MEP DRAWINGS FOR

SCOPE OF DEMOLITION.

THIS SHADED AREA REPRESENTS THE

APPROXIMATE CEILING AREA TO BE

PRESERVED IN THIS BID ITEM.

SEE SPECIFICATIONS AND ALSO

NARRATIVE ON G-105.

PATIENT LIFT AND CUBICLE CURTAIN

TRACKS TO REMAIN IN PATIENT ROOMS

WITHIN SHADED AREA.

NOT IN

SCOPE OF

WORK

SEE BID ITEM 1 FOR DEMOLITION

NOTES FOR THIS AREA (UN-SHADED)

SEE BID ITEM 1 FOR DEMOLITION

NOTES FOR THIS AREA (UN-SHADED)

CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO WORK BEGINNING.

THE CONTRACTOR IS RESPONSIBLE FOR INFORMING THE COR OF ANY CONDITIONS

THAT DIFFER FROM THE INFORMATION INDICATED IN THE DRAWINGS.

A.

GENERAL DEMOLITION NOTES:

PROTECT ALL EXISTING BUILDING COMPONENTS WHICH ARE TO REMAIN. REPAIR ANY

DAMAGED AREAS AS REQUIRED TO RETURN THEM TO THEIR ORIGINAL CONDITION.

B.

VERIFY EXTENT OF DEMOLITION WORK WITH INFORMATION SHOWN IN THE

DRAWINGS, AND WORK THAT IS NOT SHOWN AND MAY BE REQUIRED TO COMPLETE

THE INTENDED WORK.

C.

ALL WORK SHALL COMPLY WITH REQUIRED LOCAL CODES. CONTRACTOR IS

RESPONSIBLE FOR OBTAINING REQUIRED PERMITS AND INSPECTIONS FOR ALL

WORK ASSOCIATED WITH THIS CONTRACT.

D.

CONTRACTOR SHALL REPAIR ALL DISTURBED AREAS AS REQUIRED TO MATCH

SURROUNDING EXISTING FINISHES NOT DISTURBED.

E.

TYPES OF FLOOR, WALL, AND CEILING FINISHES INDICATED FOR REMOVAL BY

DEMOLITION NOTES IS FOR GENERAL INFORMATION ONLY FROM INFORMATION OBTAINED

FROM EXISTING PLANS AND OBSERVATIONS. CONTRACTOR SHALL FIELD VERIFY

MATERIAL TYPES ONSITE PRIOR TO BID AND INCLUDE NECESSARY WORK IN HIS BID.

F.

ALL AUTOMATIC DOOR OPERATORS, ACCESS CONTROL & DOOR HARDWARE,

APPLIANCES, FURNITURE, AND EQUIPMENT TO REMAIN THE PROPERTY OF THE

OWNER - CONTRACTOR TO COORDINATE REMOVAL, RELOCATION, STORAGE OF

EQUIPMENT FROM DEMO AREAS WITH OWNER.

G.

PATCH FLOOR AT REMOVED WALLS AND CASEWORK PREPARE FLOOR TO RECEIVE

NEW FLOORING AS REQUIRED.

H.

PATCH ALL HOLES IN EXISTING SLAB LEFT FROM REMOVAL OF FIXTURES.I.

REMOVE ALL WALL PROTECTION CAREFULLY AND RETURN TO OWNER.J.

CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL MATERIAL IN A LEGAL MANNER

NOT SCHEDULED FOR REUSE UNDER THIS PROJECT.

K.

IN ALL WALLS AND CEILINGS THAT ARE TO BE REMOVED THE CONTRACTOR SHALL

BE RESPONSIBLE FOR DISCONNECTING AT SOURCE AND REMOVING OR CAPPING

ELECTRICAL, PLUMBING, GAS LINES AND MECHANICAL DUCTWORK THAT IS

DISCLOSE AND NOT SCHEDULED FOR REUSE. CONTRACTOR SHALL REROUTE AND

CONTINUE ANY SYSTEM THAT MUST BE RETAINED FOR NEW CONSTRUCTION.

L.

ALL ELECTRICAL CIRCUITS FOR EQUIPMENT THAT IS TO BE REMOVED SHALL BE

DISCONNECTED AT SOURCE AND REMOVED.

M.

ALL PIPING GAS, WATER SUPPLY, VENT, DRAIN LINES, ETC. SUPPLYING EQUIPMENT

THAT IS TO BE REMOVED SHALL BE DISCONNECTED, REMOVED AND CAPPED

ABOVE CEILING OR BELOW FLOOR. CONTRACTOR SHALL REROUTE AS NECESSARY,

TO BE BEHIND NEW CONSTRUCTION. (PATCH FLOOR BACK PRIOR TO TOPPING.)

N.

ALL MED GASES AND PLUMBING TO BE REMOVED AT WALLS SCHEDULED FOR

DEMOLITION.

O.

REMOVE ALL PLUMBING FIXTURES AND EQUIPMENT WITHIN ROOMS SCHEDULED TO

BE DEMOLISHED. SEE MEP PIPING DRAWINGS.

P.

RETURN ALL SIGNAGE AFFECTED BY CONSTRUCTION TO OWNER.Q.

CONTRACTOR TO COORDINATE INFECTIOUS CONTROL REQUIREMENTS WITH

OWNER PRIOR TO ANY CONSTRUCTION.

R.

REMOVE ALL WINDOW TREATMENTS AND HARDWARE.S.

REMOVE ALL CUBICLE CURTAINS AND ASSOCIATED TRACKS IN AREAS TO BE REMODELED

AND RETURN TO OWNER.

T.

REMOVE ALL WALL-MOUNTED COMPUTER DESKS, MONITORS, ETC. AND RETAIN

FOR REINSTALLATION PER EQUIPMENT PLANS.

U.

REMOVE ALL AUTOMATIC DOOR OPERATOR HARDWARE WITHIN THE PROJECT

AREA AND RETURN TO THE VA.

V.

Drawing Title Project Title

Date

Location

Checked

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

589A7-17-203

Robert J. Dole VA Medical Center

RENOVATE WARDS FOR PATIENT

PRIVACY PHASE 1, B1

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA

142 N. MOSELY ST

WICHITA, KANSAS FINAL CONSTRUCTION DOCUMENTS

AD-102.3

3RD FLOOR DEMOLITION BID ITEM 3

Wichita, Kansas

DCW RMC04-27-2018

1/8" = 1'-0"1

PARTIAL 3RD FLOOR - DEMO PLAN BID ITEM 3

1/8" = 1'-0"2

PARTIAL 3RD FLOOR - CEILING DEMO PLAN BID ITEM 3

N 4' 8' 16'

1/8" = 1'-0"

0'

N 8' 16' 32'

1/16" = 1'-0"

0'

BID ITEM 3

SEE SPECIFICATION SECTION 01 00 00

FOR FIELD VERIFICATION OF EXISTING

CONCRETE COLUMN, BEAM, AND JOIST LOCATIONS.

No. Description Date

SEE SPECIFICATION SECTION 01 00 00

FOR FIELD VERIFICATION OF EXISTING

CONCRETE COLUMN, BEAM, AND JOIST LOCATIONS.

SEE SPECIFICATION SECTION 01 00 00

FOR MANOMETER REQUIREMENTS AT EACH FLOOR

DURING CONSTRUCTION ACTIVITIES.

SEE SPECIFICATION SECTION 01 35 26 FOR

INFECTION CONTROL REQUIREMENTS FOR THIS

PROJECT.

REQUIREMENTS INCLUDE, BUT ARE NOT LIMITED

TO CONSTRUCTION PARTITIONS, NEGATIVE AIR

PRESSURE WITHIN CONSTRUCTION AREAS, AND

NOT IN

SCOPE OF

WORK

NOT IN

SCOPE OF

WORK

NOTE:

ALSO REF. MEP DRAWINGS FOR

SCOPE OF DEMOLITION.

THIS SHADED AREA REPRESENTS THE

APPROXIMATE CEILING AREA TO BE

PRESERVED IN THIS BID ITEM.

(ALL PATIENT ROOMS AND SUPPORTINGS

SPACES IN THE WEST WING OF 3RD FLOOR.

SEE SPECIFICATIONS AND ALSO

NARRATIVE ON G-105.

PATIENT LIFT AND CUBICLE CURTAIN

TRACKS TO REMAIN IN PATIENT ROOMS

WITHIN SHADED AREA.

SEE BID ITEM 1 FOR DEMOLITION

NOTES FOR THIS AREA (UN-SHADED)

UP

DN

NOT IN

SCOPE OF

WORK

NOT IN

SCOPE OF

WORK

ALSO REF. MEP DRAWINGS FOR

SCOPE OF DEMOLITION.

PROTECT EXISTING STRUCTURE

FROM DAMAGE. TYPICAL FOR ALL

LOCATIONS.

THIS SHADED AREA REPRESENTS THE

APPROXIMATE AREA TO BE

PRESERVED IN THIS BID ITEM

(ALL PATIENT ROOMS AND SUPPORTINGS

SPACES IN THE WEST WING OF 3RD FLOOR.

SEE SPECIFICATIONS AND ALSO

NARRATIVE ON G-105.

RE-BUILDING OF CHASE REMAIN

IN PROJECT IN THIS BID ITEM

SEE BID ITEM 1 FOR DEMOLITION

NOTES FOR THIS AREA (UN-SHADED)

BID ITEM 4 - AREAS AFFECTED

CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO WORK BEGINNING.

THE CONTRACTOR IS RESPONSIBLE FOR INFORMING THE COR OF ANY CONDITIONS

THAT DIFFER FROM THE INFORMATION INDICATED IN THE DRAWINGS.

A.

GENERAL DEMOLITION NOTES:

PROTECT ALL EXISTING BUILDING COMPONENTS WHICH ARE TO REMAIN. REPAIR ANY

DAMAGED AREAS AS REQUIRED TO RETURN THEM TO THEIR ORIGINAL CONDITION.

B.

VERIFY EXTENT OF DEMOLITION WORK WITH INFORMATION SHOWN IN THE

DRAWINGS, AND WORK THAT IS NOT SHOWN AND MAY BE REQUIRED TO COMPLETE

THE INTENDED WORK.

C.

ALL WORK SHALL COMPLY WITH REQUIRED LOCAL CODES. CONTRACTOR IS

RESPONSIBLE FOR OBTAINING REQUIRED PERMITS AND INSPECTIONS FOR ALL

WORK ASSOCIATED WITH THIS CONTRACT.

D.

CONTRACTOR SHALL REPAIR ALL DISTURBED AREAS AS REQUIRED TO MATCH

SURROUNDING EXISTING FINISHES NOT DISTURBED.

E.

TYPES OF FLOOR, WALL, AND CEILING FINISHES INDICATED FOR REMOVAL BY

DEMOLITION NOTES IS FOR GENERAL INFORMATION ONLY FROM INFORMATION OBTAINED

FROM EXISTING PLANS AND OBSERVATIONS. CONTRACTOR SHALL FIELD VERIFY

MATERIAL TYPES ONSITE PRIOR TO BID AND INCLUDE NECESSARY WORK IN HIS BID.

F.

ALL AUTOMATIC DOOR OPERATORS, ACCESS CONTROL & DOOR HARDWARE,

APPLIANCES, FURNITURE, AND EQUIPMENT TO REMAIN THE PROPERTY OF THE

OWNER - CONTRACTOR TO COORDINATE REMOVAL, RELOCATION, STORAGE OF

EQUIPMENT FROM DEMO AREAS WITH OWNER.

G.

PATCH FLOOR AT REMOVED WALLS AND CASEWORK PREPARE FLOOR TO RECEIVE

NEW FLOORING AS REQUIRED.

H.

PATCH ALL HOLES IN EXISTING SLAB LEFT FROM REMOVAL OF FIXTURES.I.

REMOVE ALL WALL PROTECTION CAREFULLY AND RETURN TO OWNER.J.

CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL MATERIAL IN A LEGAL MANNER

NOT SCHEDULED FOR REUSE UNDER THIS PROJECT.

K.

IN ALL WALLS AND CEILINGS THAT ARE TO BE REMOVED THE CONTRACTOR SHALL

BE RESPONSIBLE FOR DISCONNECTING AT SOURCE AND REMOVING OR CAPPING

ELECTRICAL, PLUMBING, GAS LINES AND MECHANICAL DUCTWORK THAT IS

DISCLOSE AND NOT SCHEDULED FOR REUSE. CONTRACTOR SHALL REROUTE AND

CONTINUE ANY SYSTEM THAT MUST BE RETAINED FOR NEW CONSTRUCTION.

L.

ALL ELECTRICAL CIRCUITS FOR EQUIPMENT THAT IS TO BE REMOVED SHALL BE

DISCONNECTED AT SOURCE AND REMOVED.

M.

ALL PIPING GAS, WATER SUPPLY, VENT, DRAIN LINES, ETC. SUPPLYING EQUIPMENT

THAT IS TO BE REMOVED SHALL BE DISCONNECTED, REMOVED AND CAPPED

ABOVE CEILING OR BELOW FLOOR. CONTRACTOR SHALL REROUTE AS NECESSARY,

TO BE BEHIND NEW CONSTRUCTION. (PATCH FLOOR BACK PRIOR TO TOPPING.)

N.

ALL MED GASES AND PLUMBING TO BE REMOVED AT WALLS SCHEDULED FOR

DEMOLITION.

O.

REMOVE ALL PLUMBING FIXTURES AND EQUIPMENT WITHIN ROOMS SCHEDULED TO

BE DEMOLISHED. SEE MEP PIPING DRAWINGS.

P.

RETURN ALL SIGNAGE AFFECTED BY CONSTRUCTION TO OWNER.Q.

CONTRACTOR TO COORDINATE INFECTIOUS CONTROL REQUIREMENTS WITH

OWNER PRIOR TO ANY CONSTRUCTION.

R.

REMOVE ALL WINDOW TREATMENTS AND HARDWARE.S.

REMOVE ALL CUBICLE CURTAINS AND ASSOCIATED TRACKS IN AREAS TO BE REMODELED

AND RETURN TO OWNER.

T.

REMOVE ALL WALL-MOUNTED COMPUTER DESKS, MONITORS, ETC. AND RETAIN

FOR REINSTALLATION PER EQUIPMENT PLANS.

U.

REMOVE ALL AUTOMATIC DOOR OPERATOR HARDWARE WITHIN THE PROJECT

AREA AND RETURN TO THE VA.

V.

Drawing Title Project Title

Date

Location

Checked

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

589A7-17-203

Robert J. Dole VA Medical Center

RENOVATE WARDS FOR PATIENT

PRIVACY PHASE 1, B1

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA

142 N. MOSELY ST

WICHITA, KANSAS FINAL CONSTRUCTION DOCUMENTS

AD-102.4

3RD FLOOR DEMOLITION BID ITEM 4

Wichita, Kansas

DCW RMC04-27-2018

N 4' 8' 16'

1/8" = 1'-0"

0'

N 8' 16' 32'

1/16" = 1'-0"

0'

1/8" = 1'-0"1

PARTIAL 3RD FLOOR - CEILING DEMO PLAN BID ITEM 4

1/8" = 1'-0"2

PARTIAL 3RD FLOOR - DEMO PLAN BID ITEM 4

BID ITEM 4

SEE SPECIFICATION SECTION 01 00 00

FOR FIELD VERIFICATION OF EXISTING

CONCRETE COLUMN, BEAM, AND JOIST LOCATIONS.

No. Description Date

SEE SPECIFICATION SECTION 01 00 00

FOR FIELD VERIFICATION OF EXISTING

CONCRETE COLUMN, BEAM, AND JOIST LOCATIONS.

SEE SPECIFICATION SECTION 01 00 00

FOR MANOMETER REQUIREMENTS AT EACH FLOOR

DURING CONSTRUCTION ACTIVITIES.

SEE SPECIFICATION SECTION 01 35 26 FOR

INFECTION CONTROL REQUIREMENTS FOR THIS

PROJECT.

REQUIREMENTS INCLUDE, BUT ARE NOT LIMITED

TO CONSTRUCTION PARTITIONS, NEGATIVE AIR

PRESSURE WITHIN CONSTRUCTION AREAS, AND

WALL MATERIALS

LEGEND FOR WALL TAGS

MATERIAL

WIDTH

L - LIGHT GAUGE METAL STUDS, 25 ga. (REF. SPECS.)

WALL WIDTHS

0 - 5/8" GYP. BD.

1 - 1 5/8" HAT CHANNEL/ STUDS

2 - 2 1/2" METAL STUD/SHAFT WALL FRAMING

(SHAFT WALL WHERE NOTED AS FIRE RATED)

3 - 3 5/8" METAL STUD FRAMING

4 - 4" SHAFT WALL STUD FRAMING

NOTES:

PROVIDE ACCOUSTICAL SEALANT AT TOP & BOTTOM AND ALL

PENETRATIONS OF WALLS WITH SOUND BATT.

ALL STUD FRAMING TO BE 16" O.C., TYP.

PROVIDE CEMENTIOUS BACKER BOARD AT ALL SHOWER & WET

AREAS AND AS BACKER FOR CERAMIC WALL TILE. TOILET & SINK

AREAS TO RECEIVE MOISTURE-RESISTANT GYP BOARD.

PROVIDE SEALANT AT TOP & BOTTOM AND ALL PENETRATIONS OF

SMOKE PARTITION WALLS AS REQUIRED BY CODE.

PROVIDE ALL NEW WALLS THAT GO TO STRUCTURE w/ 1 1/2"

MTL. DEFLECTION TRACK

N - NONE

A - ACC0USTICAL

XXXC

INSULATION

WALL INSULATION

WALL HEIGHT

SHADED WALLS INDICATES WALLS

THAT EXTEND TO DECK

INSTALL 5/8" TYPE X GYP BD ON ONE SIDE OF FURRING,

TYP. INSTALL 5/8" TYPE X GYP BD ON BOTH SIDES OF

STUD FRAMING, TYP., UNLESS NOTED OTHERWISE.

EXTEND GYP BD TO 6" ABOVE CEILING UNLESS

REQUIRED OTHERWISE. PROVIDE ACCOUSTICAL

SEALANT AT TOP AND BOTTOM OF ALL PENETRATIONS

OF WALL WITH SOUND BATT.

WALLS TO RECEIVE GYPSUM BOARD PRODUCT ON BOTH

FACES OF METAL STUD AND WALLS THAT REQUIRE

ACOUSTICAL SOUND BATT INSULATION SHALL BE

CONSTRUCTED TO MEET A MINIMUM 45 STC UNLESS

OTHERWISE NOTED.

FIRE TAPE AND/OR FILL VOIDS AT TOP OF WALL - FIRE

RATED WALL AS REQUIRED BY CODE - REF. SPEC.

PROVIDE SEALANT AT TOP & BOTTOM AND ALL

PENETRATIONS ON ONE SIDE OF SMOKE PARTITION

WALLS AS REQUIRED BY CODE - REF. SPECS

INSTALL FIRE RATED SEAL/CLOSURE @ ALL OPENINGS,

GAPS AND TOP & BOTTOM OF FRAMING AS SPECIFIED.

BRACE ALL STUD WALLS TO STRUCTURE ABOVE @ 4'-0" O.C.

OR EXTEND ALL STUDS TO DECK ABOVE, TYP.

T - THERMAL

REF CODE SHEET

G - GYP. BD. ATTACH TO FACE OF EXISTING (SHIM AS

REQD.)

DN

UP

PATIENT

ROOM

221-1

TOILET

220-1

SOILED

UTILITY

218-1

TOILET

217-1

PATIENT

ROOM

216-1

AIRBORNE

INFECTION

ISO.

PATIENT

ROOM

214-1

TOILET

213-1

PATIENT

ROOM

211-1

TOILET

209-1

PATIENT

ROOM

208-1

PATIENT

ROOM

204-1

BARIATRIC

PATIENT

ROOM

202-1

PATIENT

ROOM

233-1

PATIENT

ROOM

234-1 PATIENT

ROOM

236-1

TOILET

232-1

ANTE RM

215-1

CHARTING

206-1

TOILET

238-1

NURSE

STATION

224-1

EXIST.

STAIRS

2-STAIR-W

TOILET

210-1

TOILET

203-1

TOILET

205-1

CORR

200-1

CORR

201-1

CORR

225-1CORR

212-1

CORR

219-1

CORR

207-1

STAFF

TOILET

222-1

HSKPG

240-1

221-1

220-1

218-1

216-1

215-1214-1

213-1

222-1

211-1

210-1

209-1

208-1

202-1

203-1

204-1

205-1

232-1

231-1

233-1

236-1

NOT IN

SCOPE OF

WORK

NOT IN

SCOPE OF

WORK

1' - 6" 8' - 10" 18' - 3" 4"

/2

4"

19' - 2"

4" 7' - 9" 1' - 3" 8' - 1" 2' - 1" 8' - 2"

19' - 8"

4"

4"

19' - 10"

1' - 0" 12' - 0"

4"

4"

12' - 0" 7' - 2" 8' - 2" 2' - 1" 17' - 7" ± 4"

8' - 11 1/2"

M

IN

C

L E

A R

7' - 0 1/2"

L3A

L2N

L3A

L2N

L2NL3T

L3A

L3A

L3A

L3A

L2N

L2N

L3A

L2N

L3N

L2N

L3A

L3A

L3A

L2N

G0N

L3T

L3A

L3A

L3A

L2A

L2N

L2N

G0N

L3A

L2N

L2NG0N

L3A

L3A

L3A

M

IN

C

L E

A R

5' - 5 1/4"

L3T

L3A L3N

L3AC

L3A

L3AC

L3AC

L2N

L3T

G0N

L3AC

L3AC

L2N

L3N

L2N

G0N

L3AC

L3AC L3A

L3A

L3AC

M

IN

C

L E

A R

L3A

L3A

G0N

L3AC

L2N

L2N

L2N

G0N

L2N

G0NG0NG0N

L2N

L2N

L2N

L2N

L3A

L2N

L3T

L3AC

G0N

L3T L1N L3T

L1N

L3T

L3T

L3T

L3TL3T

L3T

L3T

L3T

L3T

L3TL3A L3T

L3A

L3T

L3T

L3T

L3T

L3T G0N

L2N

L2N

L2N

L2N

G0N

5' - 5" * 4"

L3A

L3T

L3A L3T

L3N

L3T

L3T

L3A

L3T

L3A

L2N

L2N

L1N

L2NL3A

L3A

L3T

L3A

L3A

L3A

L3A

L3A

8'-0" MIN. CLEAR

4"

4' - 11 1/4"

L3AC

L3AC

L3AC

L3AC

L3AC

L3AC

L3A

L3AL2N

L3A

L2N

L2NL3A

L3T

L3T

L3T

L3AL3T

L3A

L3A

L3A

L3A

L3A L3A

L2N

L2NL3A

L3A L3A

L3A L3A

L3A

L3A

L3A

L3A

G0N

L3T

G0N

L3T

L2N

1' - 0"

/4

2' - 5"

1L3A L3A L1N

L3AL2N

L2N

L3T

L3A

L3T

L3A

L3A

L2N

L3A

L2N

L3A

L3A

3' - 2"

4" 2' - 10"

L3A

L3A L3A

L3N

L3A L3N

L3T

G0N

L3T

L3T

L3T

L3T

L3T

L3AL3A

L2N

L2N

L3T G0N

G0N 1

L3A

L3T

2 2

5' - 5" * 3' - 5"

/1

8'

8'-0" MIN. CLEAR

/4

3' - 11 1/4"

7' - 1"

/4

12' - 5" 4"

L3A L3A

L3A

L3N

L3N

L3A

L3A

L3A

L3A

L3A

L3A

L3AL3A

L3N

L3A

L3A

L3T

L3T

L2N L3T

L3T

L3T

1 1

L1N

L1N

SHAFT

CUBICLE

CURTAIN &

TRACK

(CCT)

AI-301

AI-301

AI-301 4

AI-30116

AI-303

AI-303

AI-303 8

AI-303 AI-303

AI-303

AI-303 27

L3TL3T

L3A

RECEPTION

241-1

ELECT.

228-1

EQUIP.

STOR.

229-1

NOURISH.

227-1

MEDICATION

230-1

CLEAN

UTILITY

231-1

L4AC

L4AC

L3N

L3N

228-1

229-1

230-1

240-1

238-1

L3A L3A

EXISTING CLOSET

TO REMAIN

L2N

L2N

L2N

L3A

L3A

L3A

L3N

L3A

L2N

L3A

L3AC

L3AC

L3AC

L2AC

L2AC

L3A

L3A

L2N

ALCOVE

201A-1

L3AC

AI-3015

AI-301

AI-302

5 AI-3028

AI-301

G0N

L2N

G0N

L2N

CLEAN

LINEN

201B-1

AS-101

L3T

L3T

AS-101

AS-101

Sim

L3A

E X

IS

T

D

O O

R T

O R

E M

A

IN

E X

IS

T

D

O O

R T

O R

E M

A

IN

EXIST. DOOR

TO REMAIN

EXIST. DOOR

TO REMAIN

217-1

E X

IS

T

D

O O

R T

O R

E M

A

IN

AI-302

AI-301 12

AS-3012

AI-303

AI-303

AI-302 16

AS-101

/4

7' - 11" 6' - 0" 11' - 3" ± 4"12' - 6" 3' - 11" 5' - 5" *

2' - 6"

/2

ALL

REV

5' - 5" * 3' - 5"7' - 10" 1' - 3"

L3N

L3AC

L3A

L3A

G0N

G0N G0N

AI-303 7

AI-303

3 3

3 3

3 3

L3A

L3A

L3A

AI-30111

AI-301

FLOOR PENETRATION IS EXISTING.

EXIST. CHASE/SHAFT WALLS TO

BE DEMOLISHED AND REBUILT

AFTER NEW MEP WORK IS IN

PLACE.

TOILET

235-1

L3A

L3A

L3N

235-1

L3A

L3A

5' - 5" *

AI-303

L3AC

L3A

L3A

AI-301

TOILET

237-1

L2N

L3AAI-303

L3N

L3N

L3N

L3N

234-1

L3N

L3N

AI-301 2

3' - 0 1/2"

TYP.

AS-101

TYP.

G0N

L3N

AI-3018

AI-301 8

AI-301

AI-301

AI-301 8

AI-301

AI-3012

AI-301

AI-301

AI-301

AI-301

AI-301

207-1

L3A

NOT IN

SCOPE OF

WORK

3' - 4" 4' - 1" 2' - 10"

2' - 1" 8' - 2" 1' - 4 1/2"

3' - 8 1/2"

/2

/2

/2

/2

/2

7' - 2 1/2"

3' - 8" 3' - 6 1/2"

8"

14' - 9" 1' - 6 1/2"

11' - 5 1/2"

/2

/2

1' - 3"

2' - 11"7' - 5"2' - 3" 5' - 7"8' - 3"6' - 10"

L3N

6' - 10"

L3A

1' - 2"

/2

3' - 6" 2' - 11"

8' - 7 1/2" 8' - 6" 3' - 1 1/2" 11' - 7 1/2"

8' - 2 1/2"

4 4

4 4

1' - 6" 5' - 4" 1' - 6" 1' - 8"

5' - 2 1/2" 1' - 6" 5' - 4" 1' - 6"

/2

4 1/2" 1' - 6" 5' - 4" 1' - 6"

11 1/2"

1' - 6"

5' - 4" 1' - 6"

1' - 6" 5' - 4" 1' - 6" 1' - 10 1/2"

7 1/2" 1' - 6" 6' - 4" 1' - 6" 8 1/2"

/2

CUBICLE

CURTAIN &

TRACK

(CCT)

CUBICLE

CURTAIN &

TRACK

(CCT)

CUBICLE

CURTAIN &

TRACK

(CCT)

CUBICLE

CURTAIN &

TRACK

(CCT)

CUBICLE

CURTAIN &

TRACK

(CCT)

CUBICLE

CURTAIN &

TRACK

(CCT) CUBICLE

CURTAIN &

TRACK

(CCT)

CUBICLE

CURTAIN &

TRACK

(CCT)

AS-301

AS-301 3

AI-303

11' - 1 1/2"6' - 1 1/2" 5' - 5 1/2" 6' - 7 1/2" 5' - 5"

1' - 4 1/2"

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

M

IN

C

L E

A R

8'-0" MIN. CLEAR

235-8 1' - 6" 7' - 7 1/2"

1' - 3 1/2"

AS-101

TYP.

AI-105

AI-105

FLOOR SLOPING TYPE A

- SEE TOILET 335-1.

FLOOR SLOPING TYPE A

- SEE TOILET 335-1.

FLOOR SLOPING TYPE A

- SEE TOILET 335-1.

FLOOR SLOPING TYPE A

- SEE TOILET 335-1.

FLOOR SLOPING TYPE A

- SEE TOILET 335-1.

FLOOR SLOPING TYPE B

- SEE TOILET 321-1.

TYPICAL FLOOR SLOPING

- TYPE C

TYPICAL FLOOR SLOPING

- TYPE E

FLOOR SLOPING TYPE F

- SEE TOILET 303-1.

L3T

LEVEL

L3N

L3N

L3N

L3A L3A

L3A

L3A L3A

L3A

L3A

L3A

L3A

L3A

L3A

G0N

L3A

CLOSET

207A-1

PHASE 1 PROJECT

N

KEY PLAN - 2ND FLOOR

1" = 60'-0"

NEW 5/8" GYP. BD. ON

METAL STUDS

NEW 5/8" GYP. BD. (TYP.)

- ALLOW FOR MIN. 1/4" GAP ALONG

EXISTING COLUMN FACE

EXIST. CONCRETE

COLUMN

NOTE: SEE FLOOR PLANS FOR WALL TYPES AT EXIST. COLUMNS

EXIST. DOOR

AND FRAME

NEW 5/8" GYP. BD.

NEW 5/8" GYP. BD.

ON METAL STUD PARTITIONS

SEAL JOINT BETWEEN

GYP. BD. AND EXIST.

DOOR FRAME (JAMB & HEAD)

5/8" GYP. BD. ON 3 5/8" METAL

STUD PARTITION

- SEE SPECS

R15 THERMAL

BATT INSULATION

- SEE SPECS

MAINTAIN 3/8" GAP BETWEEN

EXISTING INSIDE FACE OF WALL

AND NEW STUD PARTITION

EXISTING PERIMETER/EXTERIOR

WALL TO REMAIN

SLIP TRACK WHERE NEW INTERIOR

FURRING MEETS STRUCTURE.

EXIST. RM.

CHASE

FLOOR PENETRATION IS EXISTING.

EXIST. CHASE WALLS TO BE

DEMOLISHED AND REBUILT AFTER

NEW MEP WORK IS IN PLACE.

L4AC

L4AC

L4AC

NEW PARTITIONS TO ALIGN WITH

EXISTING WALLS TO REMAIN

WHERE APPLICABLE.

EXIST. RM.

EXIST. CORR.

5/8" GYP. BD. ON 3 5/8" METAL

STUD PARTITION

- SEE SPECS

SLIP TRACK WHERE NEW INTERIOR

FURRING MEETS STRUCTURE.

ACOUSTIC ATTENUATION

BATT INSULATION

- WHERE SCHEDULED

- SEE SPECS

ACOUSTIC SEALENT AT

SILL TRACK

- WHERE ACOUSTIC BATTS

SCHEDULED

- SEE SPECS

3 5/8"

Drawing Title Project Title

Date

Location

Checked

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

589A7-17-203

Robert J. Dole VA Medical Center

RENOVATE WARDS FOR PATIENT

PRIVACY PHASE 1, B1

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA

142 N. MOSELY ST

WICHITA, KANSAS FINAL CONSTRUCTION DOCUMENTS

AS-101

1ST & 2ND FLOOR ARCH. PLANS

Wichita, Kansas

DCW RMC04-27-2018

N 2' 4' 8'0'

1/4" = 1'-0" 1/4" = 1'-0"1

2ND FLOOR - ARCHITECTURAL PLAN

PLAN NOTES - FLOOR PLAN

1 NEW METAL STUD WALL / GYP. BOARD TO BUTT TO EXISTING STRUCTURE. ALSO SEE DETAIL 2/AS-101.

2 PROVIDE BLACK-OUT FILM AT INTERIOR SIDE OF WINDOW PRIOR TO NEW WALL CONSTRUCTION REF.

SPECS.

3 PROTECT EXISTING STRUCTURE FROM DAMAGE. TYPICAL FOR ALL LOCATIONS.

4 EXISTING STEAM PIPING LOCATION (ALSO SEE MEP DRAWINGS). ENCAPSULATE WITHIN WALL FURRING.

NOTIFY C.O.R. IF ACTUAL PIPING LOCATIONS AFFECT PLANNED WALL LAYOUT.

5 VERIFY EXISTING FLOOR STRUCTURE BELOW PLUMBING. FLOOR PENETRATION CAN NOT BE THROUGH

CONCRETE BEAMS OR JOISTS.

6 VERIFY PLUMBING CHASE SPACE REQUIREMENTS.

7 NEW SOLID SURFACE WINDOW STOOL AT EXISTING WINDOW. REF. SPECS & CASEWORK DRAWINGS.

1" = 1'-0"4

TYP. COLUMN FURRING

1" = 1'-0"3

TYP. FURRING AT EXIST. DOOR

1" = 1'-0"6

TYP. PERIMETER FURRING

1/4" = 1'-0"2

1ST FLOOR - ARCHITECTURAL PLAN

N 2' 4' 8'0'

1/4" = 1'-0"

1" = 1'-0"5

TYP. INTERIOR PARTITION

SEE SPECIFICATION SECTION 01 00 00

FOR FIELD VERIFICATION OF EXISTING

CONCRETE COLUMN, BEAM, AND JOIST LOCATIONS.

NOTIFY THE C.O.R. OF ANY CONFLICTS BETWEEN

CONCRETE STRUCTURE (COLUMNS, BEAMS, OR

JOISTS) AND NEW DESIGN ELEMENTS BEFORE

COMMENCEMENT OF NEW CONSTRUCTION OF

EACH PHASE.

No. Description Date

1" = 1'-0"7

TYP. HEADWALL PILASTER

5/8" GYP. BD.

3 5/8" METAL

STUDS

ACOUSTIC

ATTENUATION BATT

INSULATION

TWO AT EACH PATIENT ROOM (AT ROOM HEADWALL)

WALL MATERIALS

LEGEND FOR WALL TAGS

MATERIAL

WIDTH

L - LIGHT GAUGE METAL STUDS, 25 ga. (REF. SPECS.)

WALL WIDTHS

0 - 5/8" GYP. BD.

1 - 1 5/8" HAT CHANNEL/ STUDS

2 - 2 1/2" METAL STUD/SHAFT WALL FRAMING

(SHAFT WALL WHERE NOTED AS FIRE RATED)

3 - 3 5/8" METAL STUD FRAMING

4 - 4" SHAFT WALL STUD FRAMING

NOTES:

PROVIDE ACCOUSTICAL SEALANT AT TOP & BOTTOM AND ALL

PENETRATIONS OF WALLS WITH SOUND BATT.

ALL STUD FRAMING TO BE 16" O.C., TYP.

PROVIDE CEMENTIOUS BACKER BOARD AT ALL SHOWER & WET

AREAS AND AS BACKER FOR CERAMIC WALL TILE. TOILET & SINK

AREAS TO RECEIVE MOISTURE-RESISTANT GYP BOARD.

PROVIDE SEALANT AT TOP & BOTTOM AND ALL PENETRATIONS OF

SMOKE PARTITION WALLS AS REQUIRED BY CODE.

PROVIDE ALL NEW WALLS THAT GO TO STRUCTURE w/ 1 1/2"

MTL. DEFLECTION TRACK

N - NONE

A - ACC0USTICAL

XXXC

INSULATION

WALL INSULATION

WALL HEIGHT

SHADED WALLS INDICATES WALLS

THAT EXTEND TO DECK

INSTALL 5/8" TYPE X GYP BD ON ONE SIDE OF FURRING,

TYP. INSTALL 5/8" TYPE X GYP BD ON BOTH SIDES OF

STUD FRAMING, TYP., UNLESS NOTED OTHERWISE.

EXTEND GYP BD TO 6" ABOVE CEILING UNLESS

REQUIRED OTHERWISE. PROVIDE ACCOUSTICAL

SEALANT AT TOP AND BOTTOM OF ALL PENETRATIONS

OF WALL WITH SOUND BATT.

WALLS TO RECEIVE GYPSUM BOARD PRODUCT ON BOTH

FACES OF METAL STUD AND WALLS THAT REQUIRE

ACOUSTICAL SOUND BATT INSULATION SHALL BE

CONSTRUCTED TO MEET A MINIMUM 45 STC UNLESS

OTHERWISE NOTED.

FIRE TAPE AND/OR FILL VOIDS AT TOP OF WALL - FIRE

RATED WALL AS REQUIRED BY CODE - REF. SPEC.

PROVIDE SEALANT AT TOP & BOTTOM AND ALL

PENETRATIONS ON ONE SIDE OF SMOKE PARTITION

WALLS AS REQUIRED BY CODE - REF. SPECS

INSTALL FIRE RATED SEAL/CLOSURE @ ALL OPENINGS,

GAPS AND TOP & BOTTOM OF FRAMING AS SPECIFIED.

BRACE ALL STUD WALLS TO STRUCTURE ABOVE @ 4'-0" O.C.

OR EXTEND ALL STUDS TO DECK ABOVE, TYP.

T - THERMAL

REF CODE SHEET

G - GYP. BD. ATTACH TO FACE OF EXISTING (SHIM AS

REQD.)

UP

DN

PATIENT

ROOM

336-1

EQUIP.

STOR.

338-1

EQUIP.

ALCOVE

300-1HALL

301-1

HALL

326-1

HALL

339-1

336-1

338-1

323-1

322-1

321-1

320-1

319-1

317-1

316-1

314-1

313-1

311-1

310-1

309-1

308-1

302-1

303-1

304-1

305-1

NOT IN

SCOPE OF

WORK

NOT IN

SCOPE OF

WORK

C

L E

A N

M

IN

2' - 6" 12' - 11"

7' - 7 1/2" 5' - 5 1/2"

6' - 4 1/2"

/4

/8

8' - 2" 7' - 2 3/8" 3"

4" 12' - 6" 3' - 11" 5' - 5" 11' - 3"

4"

5' - 5" * 4"

8'-0" MIN. CLEAR

6' - 0"

8" 16' - 9" 2' - 1" 8' - 2" 2' - 1"

3' - 8"

4"

19' - 10"

2 2 2

222 2 2

2 2

/2

/2

4" 8' - 0" 1' - 2"

7' - 11" 2' - 1" 8' - 2" 19' - 8" 4"

3' - 2"4" 2' - 10" 5

1 1

1 1

1' - 6" 8' - 10" 18' - 3" 4"

5' - 5" * 3' - 5"

8'-0" MIN. CLEAR

8'

3' - 11"

7' - 1"

/2

3' - 8"

12' - 4 3/8" 4"

L3T L3T L3T

L3AC

L3T

L2N

L3AC

L2N

L2N

L3AC

L3A

L2N

L2N

L3A

L3N

L2N

L3A

L3A

L3A

L3A

L3A

L2N

L2N

L3A

L2N

L2N

L2N

L3A

L3A

L3A

L3A

L2T

G0N

L3AC

L3TG0N L3TL2NL3T L2NL3TL1N

L3T G0NL3TG0NL3T

G0N

L3TG0N L3T L3TL3AG0N

L2N

L2N

L2N L2N

L3T

L3A

L3T

L3A

L3A

L3A

L3A

L3A

L3A

L3T

L3T

L3AL3N

L3A

L3T

L3A

L3A

L3T

L3T

G0N

L3A

L3A

L3A

L3A

L3A

L3T L3T

L3T

L3A

L3A

L3N

L3T

L3T

L3A L3A

L3A

L2N

L3A

L3N

L3A

L3A

L3A

L3A

L3A

L2N

L3A

L2N

L3A

L2N L3A

L3A

L3A L3A

L3A

L3N

L3A

L3A

L3A

L2N

L3A

L2N

L3A

L3A

L3AL3A

L3A

L1N

L3A

L3T

L3T

L3T

L3T

L3T

L3T

L3T

L3T

L3ACL3AC

L3A

L3A

L3A

L3AC

L3AC

L3AC

L3AC

L3T

L2N

L2N

L3AC

L2N

L2N L3AC

L3A

L3N

L3T

L3T

L3T

L3ACL3AC

L3AC

L3AC

L3A

L3A

L3A

L2N

L2N

L2N

L3N

L3A

L2N

L3A

L2N

L2N

L2N

G0N G0N

L2N

L1NL3A

L3N

L3A

318-1

L3A

L3T

L3A

L3A

EXIST.

STAIRS

3-STAIR-W

AS-301

AI-303

AI-303

AI-303

AI-303AI-303

AI-303

AI-303

AI-303

AI-303

AI-303

ELECT.

328-1

L4AC

L4AC

L4AC

L4AC

L4AC

L3A

L3A

L3A

328-1

7' - 7"

L3A

L3A L3T

L3A

L3AC

L3AC

L3AC

G0NG0N

L3N

AI-302

AS-101

Sim

L3AC

L3N

L3N

E X

IS

T

D

O O

R T

O R

E M

A

IN

EXIST. DOOR

TO REMAIN

AS-3015

AS-101

Sim

324-1

L3A

1' - 7 1/2"

/2

/2

7' - 4"

/2

AI-3038

ALL

REV

ALL

REV

3 3

3 3

3 3

5' - 6"

9' - 6 1/2"

5' - 10"

9' - 1" 10' - 9"

3' - 8" 3' - 6 1/2" 6' - 1 1/2"

L3T

17' - 7" 4"

/2

FLOOR PENETRATION IS

EXISTING. EXIST.

CHASE/SHAFT WALLS TO BE

DEMOLISHED AND REBUILT

AFTER NEW MEP WORK IS IN

PLACE.

337-1

AI-302 25

L2AC

L3A

L3A

L3A

L3AC

L3AC

L3AC

L3AC

L3T

L3N

L3N

L3N

AI-301 3AI-3014

AI-3015

AI-301 2

AI-301

AI-301

AI-30116 17

3' - 5" 5' - 5" *

CLEAN

UTILITY

330-1

TOILET

335-1

PATIENT

ROOM

334-1

SOILED

UTILITY

319-1

AIRBORNE

INFECTION

ISO.

PATIENT

ROOM

316-1

ANTE RM

318-1

TOILET

317-1

STORAGE

320-1

TOILET

321-1

PATIENT

RM

322-1

PATIENT

RM

314-1

STAFF

TOILET

323-1

TOILET

313-1

NURSE

STATION

325-1

PATIENT

RM

311-1

TOILET

310-1 TOILET

309-1

PATIENT

RM

308-1

HALL

307-1

BARIATRIC

PATIENT

ROOM

302-1

PATIENT

RM

304-1

CHARTING

306-1

TOILET

305-1

HSKPG

324-1

NOURISH.

327-1

CLOSET

307A-1

ALCOVE

301-1A

TOILET

337-1

HALL

312-1

AS-101

Sim

L3TL3TL3AC

EQUIP.

STOR.

329-1

MEDICATION

331-1

AI-3018

AI-301 8

AI-301 8

AI-3018

AI-301

AI-301

AI-301

AI-301 6

AI-301

AI-302 24

307-1

NOT IN

SCOPE OF

WORK

5 1/2" 1' - 6" 5' - 4" 1' - 6"

1' - 3 1/2" 1' - 6" 5' - 4" 1' - 6"

1' - 2" 1' - 6" 5' - 4" 1' - 6"

1' - 6" 5' - 4" 1' - 6" 2' - 1 1/2"

CUBICLE

CURTAIN &

TRACK

(CCT)

CUBICLE

CURTAIN &

TRACK

(CCT)

CUBICLE

CURTAIN &

TRACK

(CCT)

CUBICLE

CURTAIN &

TRACK

(CCT)

CUBICLE

CURTAIN &

TRACK

(CCT)

CUBICLE

CURTAIN &

TRACK

(CCT)

CUBICLE

CURTAIN &

TRACK

(CCT)

CUBICLE

CURTAIN &

TRACK

(CCT)

7 1/2" 1' - 6" 6' - 4" 1' - 6"

AI-301

AS-301 6

L3AC

L3AC

L3AC

L3AC

L3AC

L3AC

L3AC

L2AC

L3N

L3N 330-1

331-1

334-1

335-1

329-1

E X

IS

T

D

O O

R T

O R

E M

A

IN

L3N

L3N

L3N

G0N

L1N

L3A

L3A

L3A

L3A

L3A

L3AC

13' - 1" 7' - 0" 11' - 9" ±

15' - 2" ±8' - 8 1/2"8"7' - 11 1/2" ±

5' - 10"

4' - 3 1/2"

COORD. CHASE

DIMENSION WITH

MECH.

5' - 5" 3' - 4 1/2" 8' - 4 1/2"

/2

/2

6' - 9"

1' - 0"

AI-301

AI-302

L3A

AS-301

C

L E

A R

M

IN

AS-101

SimTYP.

L3A

L3A

3' - 0 1/2" 5' - 6" 6' - 6 1/2"

NOT IN

SCOPE OF

WORK

G0N

G0N

G0N

L3N

2' - 5"

2' - 4 1/2"

1' - 5"

AI-105

TYPICAL FLOOR SLOPING

- TYPE A

FLOOR SLOPING TYPE A

- SEE TOILET 335-1.

FLOOR SLOPING TYPE A

- SEE TOILET 335-1.

FLOOR SLOPING TYPE A

- SEE TOILET 335-1.

FLOOR SLOPING TYPE A

- SEE TOILET 335-1.

LEVEL

TYPICAL FLOOR SLOPING

- TYPE B

TYPICAL FLOOR SLOPING

- TYPE D

TYPICAL FLOOR SLOPING

- TYPE F

TOILET

303-1

SHAFT

L3N

L3N

L3N

L3N

L3A

L3A

LEVEL

PHASE 1 PROJECT

N

KEY PLAN - 3RD FLOOR

1" = 60'-0"

STEEL STUDS, 3 5/8" (MIN.),

20 GA. (MIN.), 24" o.c. (MAX.)

3 1/2" GLASS FIBER BATTS

5/8" GYP. BD., TYPE X

- BOTH SIDES OF PARTITION

JOINT COMPOUND APPLIED

IN TWO COATS WITH 2" TAPE.

AT EACH JOINT.

C-H STEEL STUDS

20 GA. (MIN.), 24" o.c. (MAX.)

GLASS FIBER BATTS

1" GYP. BD., TYPE X

JOINT COMPOUND APPLIED

IN TWO COATS WITH 2" TAPE.

AT EACH JOINT.

2 LAYERS, 5/8" GYP. BD., TYPE X

EXISTING CONCRETE

SLAB

3/16" STEEL PLATE FOR UP TO

12" DIAMETER HOLE REPAIR.

1/4" STEEL PLATE FOR LARGER

THAN 12" DIAMETER HOLE.

NEW CONCRETE FILL AT EXISTING

PENETRATION. SMOOTH TOP TO

BE FLUSH WITH FLOOR SLAB

3 1/2"3 1/2"

2 1/2" LENGTH CONCRETE

EPOXY SCREWS

OVERLAP, TYP.

5"

Drawing Title Project Title

Date

Location

Checked

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

589A7-17-203

Robert J. Dole VA Medical Center

RENOVATE WARDS FOR PATIENT

PRIVACY PHASE 1, B1

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA

142 N. MOSELY ST

WICHITA, KANSAS FINAL CONSTRUCTION DOCUMENTS

AS-102

3RD FLOOR ARCH. PLAN

Wichita, Kansas

DCW RMC04-27-2018

N 2' 4' 8'0'

1/4" = 1'-0" 1/4" = 1'-0"1

3RD FLOOR - ARCHITECTURAL PLAN

PLAN NOTES - FLOOR PLAN

1 NEW METAL STUD WALL / GYP. BOARD TO BUTT TO EXISTING STRUCTURE. ALSO SEE DETAIL 2/AS-101.

2 PROVIDE BLACK-OUT FILM AT INTERIOR SIDE OF WINDOW PRIOR TO NEW WALL CONSTRUCTION REF.

SPECS.

3 PROTECT EXISTING STRUCTURE FROM DAMAGE. TYPICAL FOR ALL LOCATIONS.

4 EXISTING STEAM PIPING LOCATION (ALSO SEE MEP DRAWINGS). ENCAPSULATE WITHIN WALL FURRING.

NOTIFY C.O.R. IF ACTUAL PIPING LOCATIONS AFFECT PLANNED WALL LAYOUT.

5 VERIFY EXISTING FLOOR STRUCTURE BELOW PLUMBING. FLOOR PENETRATION CAN NOT BE THROUGH

CONCRETE BEAMS OR JOISTS.

6 VERIFY PLUMBING CHASE SPACE REQUIREMENTS.

7 NEW SOLID SURFACE WINDOW STOOL AT EXISTING WINDOW. REF. SPECS & CASEWORK DRAWINGS.

1" = 1'-0"2

UL U465 1HR

1" = 1'-0"3

UL U415 1HR & 2HR

FOR USE AT 1 HR INCIDENTAL OCCUPANCY SEPARATION FIRE BARRIERS.

REFER TO SPECIFICATIONS, WHICH MAY HAVE MORE STRINGENT MATERIAL REQUIREMENTS.

FOR USE AT:

1 HR OCCUPANCY SEPARATION FIRE BARRIER (AGAINST EXISTING PARTITION), 2 1/2" MIN. STUDS.

2 HR VERTICAL OPENING FIRE BARRIER, 4" MIN. STUDS.

REFER TO SPECIFICATIONS, WHICH MAY HAVE MORE STRINGENT MATERIAL REQUIREMENTS.

SEE SPECIFICATION SECTION 01 00 00

FOR FIELD VERIFICATION OF EXISTING

CONCRETE COLUMN, BEAM, AND JOIST LOCATIONS.

NOTIFY THE C.O.R. OF ANY CONFLICTS BETWEEN

CONCRETE STRUCTURE (COLUMNS, BEAMS, OR

JOISTS) AND NEW DESIGN ELEMENTS BEFORE

COMMENCEMENT OF NEW CONSTRUCTION OF

EACH PHASE.

No. Description Date

1" = 1'-0"4

TYP. SLAB REPAIR

REF. MEP DRAWINGS FOR EXISTING PENETRATIONS TO BE ABANDONED AND REPAIRED.

PATIENT

ROOM

336-1

EQUIP.

STOR.

338-1

EQUIP.

ALCOVE

300-1

HALL

301-1

HALL

326-1

HALL

339-1

NOT IN

SCOPE OF

WORK

NOT IN

SCOPE OF

WORK

NOT IN

SCOPE OF

WORK

EXIST.

STAIRS

3-STAIR-W

PRIVACY

CURTAIN

(BY VA IN THIS BID ITEM)

ELECT.

328-1

E X

IS

T

D

O O

R T

O R

E M

A

IN

EXIST. DOOR

TO REMAIN

FLOOR PENETRATION IS

EXISTING. EXIST.

CHASE/SHAFT WALLS TO BE

DEMOLISHED AND REBUILT

AFTER NEW MEP WORK IS IN

PLACE.

MODIFIED

OFFICE

312-1-3

MODIFIED

(EXIST.)

PATIENT

RM

311-1-3

EXIST.

TOILET

EXIST.

TOILET

MODIFIED

(EXIST.)

PATIENT

RM

308-1-3

ROOMS TO BE PRESERVED IN THIS BID ITEM:

EXISTING TOILETS (2)

EXISTING PATIENT ROOMS (2) - TO BE MODIFIED TO WORK WITH NEW CORRIDOR.

EXISTING OFFICE - TO BE MODIFIED TO WORK WITH NEW TOILET TO THE NORTH.

SEE SPECIFICATIONS AND NARRATIVE ON SHEET G-105 FOR MORE INFORMATION.

SEE SPECIFICATIONS AND NARRATIVE ON SHEET G-105 FOR

ITEMS TO BE DELETED IN THESE ROOMS AND SPACES FOR

THIS BID ITEM.

SEE SPECIFICATIONS AND NARRATIVE ON SHEET G-105 FOR

ITEMS TO BE DELETED IN THESE ROOMS AND SPACES FOR

THIS BID ITEM.

SEE SPECIFICATIONS AND NARRATIVE ON SHEET G-105 FOR

ITEMS TO BE DELETED IN THESE ROOMS AND SPACES FOR

THIS BID ITEM.

SEE SPECIFICATIONS AND NARRATIVE ON SHEET G-105 FOR

ITEMS TO BE DELETED IN THESE ROOMS AND SPACES FOR

THIS BID ITEM.

CLEAN

UTILITY

330-1

TOILET

335-1

PATIENT

ROOM

334-1

SOILED

UTILITY

319-1

NURSE

STATION

325-1

NOT IN

SCOPE OF

WORK

PATIENT

RM

304-1

BARIATRIC

PATIENT

ROOM

302-1

TOILET

305-1

CHARTING

306-1

HALL

307-1

CLOSET

307A-1

AIRBORNE

INFECTION

ISO.

PATIENT

ROOM

316-1

TOILET

317-1

ANTE RM

318-1

PATIENT

RM

314-1

TOILET

313-1

STORAGE

320-1

TOILET

321-1

PATIENT

RM

322-1

STAFF

TOILET

323-1

HSKPG

324-1

TOILET

337-1

HALL

312-1

EQUIP.

STOR.

329-1

MEDICATION

331-1

330-1 331-1

329-1

337-1

336-1

338-1

323-1

324-1

307-1

304-1

305-1

308-1-3

311-1-3

312-1-3

313-1

314-1

319-1

320-1

322-1318-1316-1

321-1

334-1

EXIST. DOOR

TO REMAIN

NOT IN

SCOPE OF

WORK

E X

IS

T

D

O O

R T

O R

E M

A

IN

BID ITEM 3 - AREAS AFFECTED

E X

IS

T

D

O O

R T

O R

E M

A

IN

TOILET

303-1

Drawing Title Project Title

Date

Location

Checked

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

589A7-17-203

Robert J. Dole VA Medical Center

RENOVATE WARDS FOR PATIENT

PRIVACY PHASE 1, B1

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA

142 N. MOSELY ST

WICHITA, KANSAS FINAL CONSTRUCTION DOCUMENTS

AS-102.3

3RD FLOOR ARCH. BID ITEM 3

Wichita, Kansas

DCW RMC04-27-2018

1/4" = 1'-0"1

3RD FLOOR - BID ITEM 3 ARCHITECTURAL PLAN

N 2' 4' 8'0'

1/4" = 1'-0"

BID ITEM 3

DOOR SCHEDULE - 3RD FLOOR - BID ITEM 3

DOOR

NO. SIZE

HDWR

SET

DOOR FRAME DETAILS

REMARKSTYPE MAT'L GLASS TYPE MAT'L GLASS HEAD JAMB THRESHOLD

302-1 4' 0" x 7' 0" x 1 3/4" + 2' 0" x 7' 0" x 1 3/4" D 2 1/AS-601 1/AS-601 SIM

303-1 4' 0" x 7' 5 1/2" x 1 3/4" + 2' 0" x 7' 5 1/2" x 1 3/4" LIFT D 4 1/AS-601 1/AS-601 SIM 10/AI-102

304-1 4'-0" x 7'-0" x 1 3/4" A 1 1/AS-601 1/AS-601 SIM

305-1 3'-8" x 7'-5 1/2" x 1 3/4" LIFT A 3 1/AS-601 1/AS-601 SIM 10/AI-102

307-1 3'-0" x 7'-0" x 1 3/4" B 1 1/AS-601 1/AS-601 SIM

308-1-3 4'-0" x 7'-0" x 1 3/4" A 1 1/AS-601 1/AS-601 SIM

311-1-3 4'-0" x 7'-0" x 1 3/4" A 1 1/AS-601 1/AS-601 SIM

312-1-3 3'-0" x 7'-0" x 1 3/4" A 1 1/AS-601 1/AS-601 SIM

313-1 3'-8" x 7'-5 1/2" x 1 3/4" LIFT A 3 1/AS-601 1/AS-601 SIM 10/AI-102

314-1 4'-0" x 7'-0" x 1 3/4" A 1 1/AS-601 1/AS-601 SIM

316-1 3'-8" x 7'-0" x 1 3/4" C 1 1/AS-601 1/AS-601 SIM

317-1 3'-8" x 7'-5 1/2" x 1 3/4" LIFT A 3 1/AS-601 1/AS-601 SIM 10/AI-102

318-1 3'-8" x 7'-0" x 1 3/4" A 1 1/AS-601 1/AS-601 SIM

319-1 3'-4" x 7'-0" x 1 3/4" B 1 1/AS-601 1/AS-601 SIM 45 MIN. RATED

320-1 3'-4" x 7'-0" x 1 3/4" C 1 1/AS-601 1/AS-601 SIM

321-1 3'-8" x 7'-5 1/2" x 1 3/4" LIFT A 3 1/AS-601 1/AS-601 SIM 10/AI-102

322-1 4'-0" x 7'-0" x 1 3/4" A 1 1/AS-601 1/AS-601 SIM 45 MIN. RATED

323-1 3'-0" x 7'-0" x 1 3/4" A 1 1/AS-601 1/AS-601 SIM 9/AI-102

324-1 3'-0" x 7'-0" x 1 3/4" A 1 1/AS-601 1/AS-601 SIM

328-1 3'-0" x 7'-0" x 1 3/4" 10 A WD. - 1 H.M. - 1/AS-601 1/AS-601 SIM

329-1 3'-4" x 7'-0" x 1 3/4" B 1 1/AS-601 1/AS-601 SIM 45 MIN. RATED

330-1 3'-4" x 7'-0" x 1 3/4" B 1 1/AS-601 1/AS-601 SIM 45 MIN. RATED

331-1 3'-4" x 7'-0" x 1 3/4" B 1 1/AS-601 1/AS-601 SIM 45 MIN. RATED

334-1 3'-8" x 7'-0" x 1 3/4" C 1 1/AS-601 1/AS-601 SIM

335-1 3'-8" x 7'-5 1/2" x 1 3/4" LIFT A 3 1/AS-601 1/AS-601 SIM 10/AI-102

336-1 3'-8" x 7'-0" x 1 3/4" 3 C WD. SAFETY, FROSTED

1 H.M. 1/AS-601 1/AS-601 SIM

337-1 3'-8" x 7'-5 1/2" x 1 3/4" LIFT 4 A WD. - 3 H.M. - 1/AS-601 1/AS-601 SIM 10/AI-102

338-1 4'-0" x 7'-0" x 1 3/4" 8 B WD. SAFETY 1 H.M. - 1/AS-601 1/AS-601 SIM 45 MIN. RATED

BID ITEM 3 (DEDUCT #2):

a. PRESERVE TWO EXISTING, MULTIPLE-BED PATIENT ROOMS ON THE THIRD FLOOR AND ELIMINATE THE CONSTRUCTION OF TWO NEW PATIENT ROOMS AND SHOWER ROOMS. THE EXISTING-TO-REMAIN PATIENT ROOMS WILL

REQUIRE MODIFICATION AT THE ENTRANCES TO COMMUNICATE WITH THE NEW CORRIDOR.

CONSTRUCTION OF NEW ROOMS TO BE ELIMINATED IN THIS DEDUCT INCLUDE:

308-1, 309-1, 310-1, AND 311-1.

b. ELIMINATE CASEWORK, TOILETS AND SINKS IN SIX PATIENT ROOM/TOILETS (SEE LISTED BELOW) ON THE THIRD FLOOR AND AT ASSOCIATED LOCATIONS IN THE CORRIDORS. ALL PLUMBING AND ELECTRICAL ROUGH-INS SHALL BE PROVIDED FOR FUTURE INSTALLATION. EXCEPT IN SPACES NOT TO BE REMODELED, ALL NEW CEILINGS REMAIN IN THE PROJECT UNDER THIS BID ITEM.

302-1, 303-1, 304-1, 305-1, 313-1, 314-1, 316-1, 317-1, 318-1, 321-1, 322-1, 334-1, AND 335-1.

c. CASEWORK AND PLUMBING TO BE ELIMINATED (IN ADDITION TO THE PATIENT ROOMS LISTED ABOVE) INCLUDE CASEWORK IN 306-1, 307A-1, AND THE FOLLOWING ITEMS IN THE HALL/CORRIDOR:

EIGHT NURSE SERVERS, LINEN CABINETS, NOURISHMENT STATION, DRINKING FOUNTAIN, AND EYE WASH STATION.

d. SECOND FLOOR ROOMS AND SPACES ARE NOT AFFECTED BY THIS DEDUCT.

e. GENERALLY, DRAWING SHEETS COVERING DETAILS TO BID ITEM 3 END WITH ".3". AN EXAMPLE WOULD BE AS-102.3.

ONLY IN

BID ITEM 3

SEE SPECIFICATION SECTION 01 00 00

FOR FIELD VERIFICATION OF EXISTING

CONCRETE COLUMN, BEAM, AND JOIST LOCATIONS.

NOTIFY THE C.O.R. OF ANY CONFLICTS BETWEEN

CONCRETE STRUCTURE (COLUMNS, BEAMS, OR

JOISTS) AND NEW DESIGN ELEMENTS BEFORE

COMMENCEMENT OF NEW CONSTRUCTION.

BID ITEM FLOOR PLAN KEY NOTES

SEE BID ITEM 1 (BASE BID) FOR ROOM/SPACE DIMENSIONS AND WALL TYPES.1

No. Description Date

PATIENT

ROOM

336-1

EQUIP.

STOR.

338-1

EQUIP.

ALCOVE

300-1

NOT IN

SCOPE OF

WORK

NOT IN

SCOPE OF

WORK

NOT IN

SCOPE OF

WORK

EXIST.

STAIRS

3-STAIR-W

E X

IS

T

D

O O

R T

O R

E M

A

IN

EXIST. DOOR

TO REMAIN

ALL

REV

FLOOR PENETRATION IS

EXISTING. EXIST.

CHASE/SHAFT WALLS TO BE

DEMOLISHED AND REBUILT

AFTER NEW MEP WORK IS IN

PLACE.

EXIST.

PATIENT

RM

EXIST.

PATIENT

RM

EXIST.

PATIENT

RM

EXIST.

TOILET

EXIST.

TOILET

EXIST. RR

EXIST.

PATIENT

RM

EXIST.

NURSE

STATION

RESIDENTS'

OFFICE

EXIST.

MEDS RM.

EXIST.

CLEAN

LINEN

EXIST.

HSKPG

EXIST.

PATIENT

RM

EXIST.

OBSERVATION

EXIST. RR

EXIST.

PATIENT

RM

EXIST.

PATIENT

RM

EXIST.

NURSE

OFFICE

EXIST.

MEN'S RR

EXIST.

STAFF RR

EXIST.

ELEC.

CLOSET

EXIST

MAIN

CORR.

EXIST.

SPD

STORAGE

EXIST.

PATIENT

RM

EXIST.

CLEAN

SUPPLY

EXIST.

PATIENT

RM

EXIST.

TOILET

EXIST.

PATIENT

RM

MODIFIED

EXIST.

STORAGE

EXIST.

TELECOM

TOILET

337-1

THIS SHADED AREA REPRESENTS THE APPROXIMATE

AREA TO BE PRESERVED IN THIS BID ITEM.

SEE SPECIFICATIONS AND NARRATIVE ON

SHEET G-105 FOR MORE INFORMATION.

GENERALLY THESE SPACES ARE EXISTING TO REMAIN.

NOT IN

SCOPE OF

WORK

336-1

337-1

338-1

E X

IS

T

D

O O

R T

O R

E M

A

IN

E X

IS

T

D

O O

R T

O R

E M

A

IN

E X

IS

T

D

O O

R T

O R

E M

A

IN

E X

IS

T

D

O O

R T

O R

E M

A

IN

EXIST. DOOR

TO REMAIN

EXIST. DOOR

TO REMAIN

EXIST. DOOR

TO REMAIN

EXIST. DOOR

TO REMAIN

EXIST. DOOR

TO REMAIN

EXIST. DOOR

TO REMAIN

EXIST. DOOR

TO REMAIN

EXIST. DOOR

TO REMAIN

E X

IS

T

D

O O

R T

O R

E M

A

IN

E X

IS

T

D

O O

R T

O R

E M

A

IN

EXIST. DOOR

TO REMAIN

EXIST. DOOR

TO REMAIN

EXIST. DOOR

TO REMAIN

EXIST. DOOR

TO REMAIN

EXIST. DOOR

TO REMAIN

E X

IS

T

D

O O

R T

O R

E M

A

IN

EXIST. DOOR

TO REMAIN

EXIST. DOOR

TO REMAIN

EXIST. DOOR

TO REMAIN

EXIST. DOOR

TO REMAIN

E X

IS

T

D

O O

R T

O R

E M

A

IN

E X

IS

T

D

O O

R T

O R

E M

A

IN

E X

IS

T

D

O O

R T

O R

E M

A

IN

E X

IS

T

D

O O

R T

O R

E M

A

IN

EXIST. DOOR

TO REMAIN

E X

IS

T

D

O O

R T

O R

E M

A

IN

THIS SHADED AREA REPRESENTS THE APPROXIMATE

AREA TO BE PRESERVED IN THIS BID ITEM.

SEE SPECIFICATIONS AND NARRATIVE ON

SHEET G-105 FOR MORE INFORMATION.

GENERALLY THESE SPACES ARE EXISTING TO REMAIN.

E X

IS

T

D

O O

R T

O R

E M

A

IN

BID ITEM 4 - AREAS AFFECTED

PRIVACY

CURTAIN

(BY VA IN THIS BID ITEM)

Drawing…