UP
ROOF
OF
FIRST
FLOOR
ROOF
OF
FIRST
FLOOR
DN
UP
DN
UP
4 4
4 3 3
3 4 4
4 4
4 3 4 4 3 4 3
4 3 4 3
3 3
2 2
2 2 2 2
2 2
5 5 5 5 5 5 5
5 5
888888888888888
8 8
888 8
NOT IN
SCOPE OF
WORK
NOT IN
SCOPE OF
WORK
NOT IN
SCOPE OF
WORK
NOT IN
SCOPE OF
WORK
ALSO REF. MEP DRAWINGS FOR
SCOPE OF DEMOLITION.
12 12
PROTECT EXISTING STRUCTURE
FROM DAMAGE. TYPICAL FOR ALL
LOCATIONS.
NOT IN
SCOPE OF
WORK
EXIST. TELECOM CLOSET TO REMAIN
WALL
DOOR
CEILING
AND GRID
DEMO LEGEND
CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO WORK BEGINNING.
THE CONTRACTOR IS RESPONSIBLE FOR INFORMING THE COR OF ANY CONDITIONS
THAT DIFFER FROM THE INFORMATION INDICATED IN THE DRAWINGS.
A.
GENERAL DEMOLITION NOTES:
PROTECT ALL EXISTING BUILDING COMPONENTS WHICH ARE TO REMAIN. REPAIR ANY
DAMAGED AREAS AS REQUIRED TO RETURN THEM TO THEIR ORIGINAL CONDITION.
B.
VERIFY EXTENT OF DEMOLITION WORK WITH INFORMATION SHOWN IN THE
DRAWINGS, AND WORK THAT IS NOT SHOWN AND MAY BE REQUIRED TO COMPLETE
THE INTENDED WORK.
C.
ALL WORK SHALL COMPLY WITH REQUIRED LOCAL CODES. CONTRACTOR IS
RESPONSIBLE FOR OBTAINING REQUIRED PERMITS AND INSPECTIONS FOR ALL
WORK ASSOCIATED WITH THIS CONTRACT.
D.
CONTRACTOR SHALL REPAIR ALL DISTURBED AREAS AS REQUIRED TO MATCH
SURROUNDING EXISTING FINISHES NOT DISTURBED.
E.
TYPES OF FLOOR, WALL, AND CEILING FINISHES INDICATED FOR REMOVAL BY
DEMOLITION NOTES IS FOR GENERAL INFORMATION ONLY FROM INFORMATION OBTAINED
FROM EXISTING PLANS AND OBSERVATIONS. CONTRACTOR SHALL FIELD VERIFY
MATERIAL TYPES ONSITE PRIOR TO BID AND INCLUDE NECESSARY WORK IN HIS BID.
F.
ALL AUTOMATIC DOOR OPERATORS, ACCESS CONTROL & DOOR HARDWARE,
APPLIANCES, FURNITURE, AND EQUIPMENT TO REMAIN THE PROPERTY OF THE
OWNER - CONTRACTOR TO COORDINATE REMOVAL, RELOCATION, STORAGE OF
EQUIPMENT FROM DEMO AREAS WITH OWNER.
G.
PATCH FLOOR AT REMOVED WALLS AND CASEWORK PREPARE FLOOR TO RECEIVE
NEW FLOORING AS REQUIRED.
H.
PATCH ALL HOLES IN EXISTING SLAB LEFT FROM REMOVAL OF FIXTURES.I.
REMOVE ALL WALL PROTECTION CAREFULLY AND RETURN TO OWNER.J.
CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL MATERIAL IN A LEGAL MANNER
NOT SCHEDULED FOR REUSE UNDER THIS PROJECT.
K.
IN ALL WALLS AND CEILINGS THAT ARE TO BE REMOVED THE CONTRACTOR SHALL
BE RESPONSIBLE FOR DISCONNECTING AT SOURCE AND REMOVING OR CAPPING
ELECTRICAL, PLUMBING, GAS LINES AND MECHANICAL DUCTWORK THAT IS
DISCLOSE AND NOT SCHEDULED FOR REUSE. CONTRACTOR SHALL REROUTE AND
CONTINUE ANY SYSTEM THAT MUST BE RETAINED FOR NEW CONSTRUCTION.
L.
ALL ELECTRICAL CIRCUITS FOR EQUIPMENT THAT IS TO BE REMOVED SHALL BE
DISCONNECTED AT SOURCE AND REMOVED.
M.
ALL PIPING GAS, WATER SUPPLY, VENT, DRAIN LINES, ETC. SUPPLYING EQUIPMENT
THAT IS TO BE REMOVED SHALL BE DISCONNECTED, REMOVED AND CAPPED
ABOVE CEILING OR BELOW FLOOR. CONTRACTOR SHALL REROUTE AS NECESSARY,
TO BE BEHIND NEW CONSTRUCTION. (PATCH FLOOR BACK PRIOR TO TOPPING.)
N.
ALL MED GASES AND PLUMBING TO BE REMOVED AT WALLS SCHEDULED FOR
DEMOLITION.
O.
REMOVE ALL PLUMBING FIXTURES AND EQUIPMENT WITHIN ROOMS SCHEDULED TO
BE DEMOLISHED. SEE MEP PIPING DRAWINGS.
P.
RETURN ALL SIGNAGE AFFECTED BY CONSTRUCTION TO OWNER.Q.
CONTRACTOR TO COORDINATE INFECTIOUS CONTROL REQUIREMENTS WITH
OWNER PRIOR TO ANY CONSTRUCTION.
R.
REMOVE ALL WINDOW TREATMENTS AND HARDWARE.S.
REMOVE ALL CUBICLE CURTAINS AND ASSOCIATED TRACKS IN AREAS TO BE REMODELED
AND RETURN TO OWNER.
T.
REMOVE ALL WALL-MOUNTED COMPUTER DESKS, MONITORS, ETC. AND RETAIN
FOR REINSTALLATION PER EQUIPMENT PLANS.
U.
REMOVE ALL AUTOMATIC DOOR OPERATOR HARDWARE WITHIN THE PROJECT
AREA AND RETURN TO THE VA.
V.
PHASE 1 PROJECT
N
KEY PLAN - 2ND FLOOR
1" = 60'-0"
1 1
1 1
1 1 1 1 1 1 1
111111
NOT IN
SCOPE OF
WORK
NOT IN
SCOPE OF
WORK
NOT IN
SCOPE OF
WORK
NOT IN
SCOPE OF
WORK
NOTE:
ALSO REF. MEP DRAWINGS FOR
SCOPE OF DEMOLITION.
NOT IN
SCOPE OF
WORK
SIMULATION
LAB
VISUAL
IMPAIRMENT
SERVICES
OFFICE
RR
STORE
OFFICE
CHAPLAIN
PASTORAL
CARE
OFFICE
CHAPLAIN
OFFICE
STAIRS
ASSOCIATE
DIRECTOR
ICU
RR
NURSE
OFFICE
TELEHEALTH
GUEST
ROOM
RR
GUEST
ROOM
ELEV. CORRIDOR
CORRIDOR
ICU
WAITING
ROOM
SLEEP
RR
HEMODIALYSIS
EXAM
ROOM
HEMODIALYSIS
STORAGE
SPEECH
THERAPY
OFFICE
OFFICEBREAK AND
LOCKER
ROOM
OFFICE
RR
ELEC
EUCHARISTIC
CHAPEL
STORE
CHAPLAIN
OFFICE
CHAPEL
EDUCATION
OFFICE
EDUCATION
OFFICE
OFFICE
EDUCATION
STORAGE
STUDY
ROOM
BREAK
ROOM
STAIRS
STORAGE
STOR
RESPIRATORY
THERAPY
OFFICE
Drawing Title Project Title
Date
Location
Checked
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
589A7-17-203
Robert J. Dole VA Medical Center
RENOVATE WARDS FOR PATIENT
PRIVACY PHASE 1, B1
117 PIERCE ST, SUITE 110
SIOUX CITY, IOWA
142 N. MOSELY ST
WICHITA, KANSAS FINAL CONSTRUCTION DOCUMENTS
AD-101
1ST & 2ND FLOOR DEMOLITION
Wichita, Kansas
DCW RMC04-27-2018
1/8" = 1'-0"1
2ND FLOOR - DEMOLITION PLAN
N 4' 8' 16'
1/8" = 1'-0"
0'
DEMO SCHEDULE
1 EXISTING CEILING AND GRID TO BE REMOVED - REFER TO GENERAL DEMOLITION NOTE (N).
INCLUDES DRYWALL AND PLASTER SOFFITS WITHIN CEILING AREAS TO BE DEMOLISHED. ALL
EXISTING CEILINGS WITHIN PROJECT AREA TO BE REMOVED.
2 EXISTING FLOORING TO BE REMOVED - PREPARE AREA FOR NEW FLOOR FINISH. ALL
FLOORING WITHIN PROJECT AREA TO BE REMOVED.
3 EXISTING WALL FINISH AND WALL FURRING TO BE REMOVED - PREPARE AREA FOR NEW WALL
FINISH.
4 EXISTING WALL FINISH TO BE REMOVED - PREPARE AREA FOR NEW WALL FINISH. TYPICAL AT
ALL REMAINING PLASTER WALLS.
5 EXISTING DOOR AND FRAME AND ALL HARDWARE TO BE REMOVED.
6 EXISTING PLUMBING FIXTURE TO BE REMOVED - REFER TO GENERAL DEMOLITION NOTE (P).
7 EXISTING CASEWORK TO BE REMOVED.
8 EXISTING WALL AND ALL OF ITS BUILDING COMPONENTS TO BE REMOVED. (FULL HEIGHT) -
REFER TO GENERAL DEMOLITION NOTE (N).
9 EXISTING TOILET PARTITION AND ALL OF ITS BUILDING COMPONENTS TO BE REMOVED.
10 STAINLESS STEEL COUNTER AND WALL CABINET TO BE RELOCATED.
11 EXISTING DIALYSIS FIXTURES TO BE REMOVED. REFER TO MEP DRAWINGS.
12 EXISTING BASE UNIT HEATER TO BE REMOVED. REFER TO MEP DRAWINGS.
13 EXISTING LOCKER(S) TO BE REMOVED.
14 EXISTING CHAPEL ART GLASS INSIDE WINDOWS TO BE REMOVED. RETURN TO THE VA.
1/8" = 1'-0"2
2ND FLOOR - CEILING DEMOLITION PLAN
N 8' 16' 32'
1/16" = 1'-0"
0'
1/8" = 1'-0"3
1ST FLOOR - DEMOLITION PLAN
N 4' 8' 16'
1/8" = 1'-0"
0'
SEE SPECIFICATION SECTION 01 00 00
FOR FIELD VERIFICATION OF EXISTING
CONCRETE COLUMN, BEAM, AND JOIST LOCATIONS.
No. Description Date
SEE SPECIFICATION SECTION 01 00 00
FOR MANOMETER REQUIREMENTS AT EACH FLOOR
DURING CONSTRUCTION ACTIVITIES.
SEE SPECIFICATION SECTION 01 35 26 FOR
INFECTION CONTROL REQUIREMENTS FOR THIS
PROJECT.
REQUIREMENTS INCLUDE, BUT ARE NOT LIMITED
TO CONSTRUCTION PARTITIONS, NEGATIVE AIR
PRESSURE WITHIN CONSTRUCTION AREAS, AND
PROVISION OF ANTEROOMS AT CONSTRUCTION
ENTRANCES.
DN
4 4
4 4
4 4
4 4
4 3 4 4 4 3
4 3 4
2 2 2
2 2 2
5 5 5 5 5 5 5
5 5
888888888888
88888 8 8
6 6
NOT IN
SCOPE OF
WORK
NOT IN
SCOPE OF
WORK
12 12 12 12
ALSO REF. MEP DRAWINGS FOR
SCOPE OF DEMOLITION.
PROTECT EXISTING STRUCTURE
FROM DAMAGE. TYPICAL FOR ALL
LOCATIONS.
NOT IN
SCOPE OF
WORK
EXIST. TELECOM CLOSET TO REMAIN
131313
WALL
DOOR
CEILING
AND GRID
DEMO LEGEND
PHASE 1 PROJECT
N
KEY PLAN - 3RD FLOOR
1" = 60'-0"
1 1 1
1 1 1 1 1
1 1 1 1 1
NOT IN
SCOPE OF
WORK
NOT IN
SCOPE OF
WORK
NOTE:
ALSO REF. MEP DRAWINGS FOR
SCOPE OF DEMOLITION.
NOT IN
SCOPE OF
WORK
CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO WORK BEGINNING.
THE CONTRACTOR IS RESPONSIBLE FOR INFORMING THE COR OF ANY CONDITIONS
THAT DIFFER FROM THE INFORMATION INDICATED IN THE DRAWINGS.
A.
GENERAL DEMOLITION NOTES:
PROTECT ALL EXISTING BUILDING COMPONENTS WHICH ARE TO REMAIN. REPAIR ANY
DAMAGED AREAS AS REQUIRED TO RETURN THEM TO THEIR ORIGINAL CONDITION.
B.
VERIFY EXTENT OF DEMOLITION WORK WITH INFORMATION SHOWN IN THE
DRAWINGS, AND WORK THAT IS NOT SHOWN AND MAY BE REQUIRED TO COMPLETE
THE INTENDED WORK.
C.
ALL WORK SHALL COMPLY WITH REQUIRED LOCAL CODES. CONTRACTOR IS
RESPONSIBLE FOR OBTAINING REQUIRED PERMITS AND INSPECTIONS FOR ALL
WORK ASSOCIATED WITH THIS CONTRACT.
D.
CONTRACTOR SHALL REPAIR ALL DISTURBED AREAS AS REQUIRED TO MATCH
SURROUNDING EXISTING FINISHES NOT DISTURBED.
E.
TYPES OF FLOOR, WALL, AND CEILING FINISHES INDICATED FOR REMOVAL BY
DEMOLITION NOTES IS FOR GENERAL INFORMATION ONLY FROM INFORMATION OBTAINED
FROM EXISTING PLANS AND OBSERVATIONS. CONTRACTOR SHALL FIELD VERIFY
MATERIAL TYPES ONSITE PRIOR TO BID AND INCLUDE NECESSARY WORK IN HIS BID.
F.
ALL AUTOMATIC DOOR OPERATORS, ACCESS CONTROL & DOOR HARDWARE,
APPLIANCES, FURNITURE, AND EQUIPMENT TO REMAIN THE PROPERTY OF THE
OWNER - CONTRACTOR TO COORDINATE REMOVAL, RELOCATION, STORAGE OF
EQUIPMENT FROM DEMO AREAS WITH OWNER.
G.
PATCH FLOOR AT REMOVED WALLS AND CASEWORK PREPARE FLOOR TO RECEIVE
NEW FLOORING AS REQUIRED.
H.
PATCH ALL HOLES IN EXISTING SLAB LEFT FROM REMOVAL OF FIXTURES.I.
REMOVE ALL WALL PROTECTION CAREFULLY AND RETURN TO OWNER.J.
CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL MATERIAL IN A LEGAL MANNER
NOT SCHEDULED FOR REUSE UNDER THIS PROJECT.
K.
IN ALL WALLS AND CEILINGS THAT ARE TO BE REMOVED THE CONTRACTOR SHALL
BE RESPONSIBLE FOR DISCONNECTING AT SOURCE AND REMOVING OR CAPPING
ELECTRICAL, PLUMBING, GAS LINES AND MECHANICAL DUCTWORK THAT IS
DISCLOSE AND NOT SCHEDULED FOR REUSE. CONTRACTOR SHALL REROUTE AND
CONTINUE ANY SYSTEM THAT MUST BE RETAINED FOR NEW CONSTRUCTION.
L.
ALL ELECTRICAL CIRCUITS FOR EQUIPMENT THAT IS TO BE REMOVED SHALL BE
DISCONNECTED AT SOURCE AND REMOVED.
M.
ALL PIPING GAS, WATER SUPPLY, VENT, DRAIN LINES, ETC. SUPPLYING EQUIPMENT
THAT IS TO BE REMOVED SHALL BE DISCONNECTED, REMOVED AND CAPPED
ABOVE CEILING OR BELOW FLOOR. CONTRACTOR SHALL REROUTE AS NECESSARY,
TO BE BEHIND NEW CONSTRUCTION. (PATCH FLOOR BACK PRIOR TO TOPPING.)
N.
ALL MED GASES AND PLUMBING TO BE REMOVED AT WALLS SCHEDULED FOR
DEMOLITION.
O.
REMOVE ALL PLUMBING FIXTURES AND EQUIPMENT WITHIN ROOMS SCHEDULED TO
BE DEMOLISHED. SEE MEP PIPING DRAWINGS.
P.
RETURN ALL SIGNAGE AFFECTED BY CONSTRUCTION TO OWNER.Q.
CONTRACTOR TO COORDINATE INFECTIOUS CONTROL REQUIREMENTS WITH
OWNER PRIOR TO ANY CONSTRUCTION.
R.
REMOVE ALL WINDOW TREATMENTS AND HARDWARE.S.
REMOVE ALL CUBICLE CURTAINS AND ASSOCIATED TRACKS IN AREAS TO BE REMODELED
AND RETURN TO OWNER.
T.
REMOVE ALL WALL-MOUNTED COMPUTER DESKS, MONITORS, ETC. AND RETAIN
FOR REINSTALLATION PER EQUIPMENT PLANS.
U.
REMOVE ALL AUTOMATIC DOOR OPERATOR HARDWARE WITHIN THE PROJECT
AREA AND RETURN TO THE VA.
V.
PATIENT
ROOM
OBSERVATION
RR
PATIENT
ROOM
PATIENT
ROOM
HSKPG
CLEAN
LINEN
MEDICAL
ROOM 1
RESIDENTS
OFFICE
CORRIDOR
NURSE
OFFICE
STAIRS
PATIENT
ROOM RR
PATIENT
ROOM
STORAGE
PATIENT
ROOM
PATIENT
ROOM
NURSE
STATION
TOILET
TOILET
RR
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
MEN'S
ELEC
STAFF RR
CLEAN
SUPPLY
SPD
STORAGE PATIENT
ROOM
PATIENT
ROOM
NURSE
OFFICE EMPLOYEE
LOUNGE
EQUIPMENT
STORAGE
RECEPTION
VENDING
ELEV.
LOCKER
ROOM
STAIRS
PATIENT
ROOM
IRM
Drawing Title Project Title
Date
Location
Checked
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
589A7-17-203
Robert J. Dole VA Medical Center
RENOVATE WARDS FOR PATIENT
PRIVACY PHASE 1, B1
117 PIERCE ST, SUITE 110
SIOUX CITY, IOWA
142 N. MOSELY ST
WICHITA, KANSAS FINAL CONSTRUCTION DOCUMENTS
AD-102
3RD FLOOR DEMOLITION
Wichita, Kansas
DCW RMC04-27-2018
N 4' 8' 16'
1/8" = 1'-0"
0'
1/8" = 1'-0"1
PARTIAL 3RD FLOOR - DEMOLITION PLAN
1/8" = 1'-0"2
PARTIAL 3RD FLOOR - CEILING DEMOLITION PLAN
N 8' 16' 32'
1/16" = 1'-0"
0'
DEMO SCHEDULE
1 EXISTING CEILING AND GRID TO BE REMOVED - REFER TO GENERAL DEMOLITION NOTE (N).
INCLUDES DRYWALL AND PLASTER SOFFITS WITHIN CEILING AREAS TO BE DEMOLISHED. ALL
EXISTING CEILINGS WITHIN PROJECT AREA TO BE REMOVED.
2 EXISTING FLOORING TO BE REMOVED - PREPARE AREA FOR NEW FLOOR FINISH. ALL
FLOORING WITHIN PROJECT AREA TO BE REMOVED.
3 EXISTING WALL FINISH AND WALL FURRING TO BE REMOVED - PREPARE AREA FOR NEW WALL
FINISH.
4 EXISTING WALL FINISH TO BE REMOVED - PREPARE AREA FOR NEW WALL FINISH. TYPICAL AT
ALL REMAINING PLASTER WALLS.
5 EXISTING DOOR AND FRAME AND ALL HARDWARE TO BE REMOVED.
6 EXISTING PLUMBING FIXTURE TO BE REMOVED - REFER TO GENERAL DEMOLITION NOTE (P).
7 EXISTING CASEWORK TO BE REMOVED.
8 EXISTING WALL AND ALL OF ITS BUILDING COMPONENTS TO BE REMOVED. (FULL HEIGHT) -
REFER TO GENERAL DEMOLITION NOTE (N).
9 EXISTING TOILET PARTITION AND ALL OF ITS BUILDING COMPONENTS TO BE REMOVED.
10 STAINLESS STEEL COUNTER AND WALL CABINET TO BE RELOCATED.
11 EXISTING DIALYSIS FIXTURES TO BE REMOVED. REFER TO MEP DRAWINGS.
12 EXISTING BASE UNIT HEATER TO BE REMOVED. REFER TO MEP DRAWINGS.
13 EXISTING LOCKER(S) TO BE REMOVED.
14 EXISTING CHAPEL ART GLASS INSIDE WINDOWS TO BE REMOVED. RETURN TO THE VA.
SEE SPECIFICATION SECTION 01 00 00
FOR FIELD VERIFICATION OF EXISTING
CONCRETE COLUMN, BEAM, AND JOIST LOCATIONS.
No. Description Date
SEE SPECIFICATION SECTION 01 00 00
FOR MANOMETER REQUIREMENTS AT EACH FLOOR
DURING CONSTRUCTION ACTIVITIES.
SEE SPECIFICATION SECTION 01 35 26 FOR
INFECTION CONTROL REQUIREMENTS FOR THIS
PROJECT.
REQUIREMENTS INCLUDE, BUT ARE NOT LIMITED
TO CONSTRUCTION PARTITIONS, NEGATIVE AIR
PRESSURE WITHIN CONSTRUCTION AREAS, AND
NOT IN
SCOPE OF
WORK
NOT IN
SCOPE OF
WORK
ALSO REF. MEP DRAWINGS FOR
SCOPE OF DEMOLITION.
PROTECT EXISTING STRUCTURE
FROM DAMAGE. TYPICAL FOR ALL
LOCATIONS.
THIS SHADED AREA REPRESENTS THE APPROXIMATE
AREA TO BE PRESERVED IN THIS BID ITEM (PORTIONS OF
2 PATIENT ROOMS, 2 TOILET ROOMS AND A PORTION
OF THE ROOM TO THE NORTH.)
SEE SPECIFICATIONS AND ALSO NARRATIVE ON G-105.
NOT IN
SCOPE OF
WORK
SEE BID ITEM 1 FOR DEMOLITION
NOTES FOR THIS AREA (UN-SHADED)
SEE BID ITEM 1 FOR DEMOLITION
NOTES FOR THIS AREA (UN-SHADED)
BID ITEM 3 - AREAS AFFECTED
NOT IN
SCOPE OF
WORK
NOT IN
SCOPE OF
WORK
NOTE:
ALSO REF. MEP DRAWINGS FOR
SCOPE OF DEMOLITION.
THIS SHADED AREA REPRESENTS THE
APPROXIMATE CEILING AREA TO BE
PRESERVED IN THIS BID ITEM.
SEE SPECIFICATIONS AND ALSO
NARRATIVE ON G-105.
PATIENT LIFT AND CUBICLE CURTAIN
TRACKS TO REMAIN IN PATIENT ROOMS
WITHIN SHADED AREA.
NOT IN
SCOPE OF
WORK
SEE BID ITEM 1 FOR DEMOLITION
NOTES FOR THIS AREA (UN-SHADED)
SEE BID ITEM 1 FOR DEMOLITION
NOTES FOR THIS AREA (UN-SHADED)
CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO WORK BEGINNING.
THE CONTRACTOR IS RESPONSIBLE FOR INFORMING THE COR OF ANY CONDITIONS
THAT DIFFER FROM THE INFORMATION INDICATED IN THE DRAWINGS.
A.
GENERAL DEMOLITION NOTES:
PROTECT ALL EXISTING BUILDING COMPONENTS WHICH ARE TO REMAIN. REPAIR ANY
DAMAGED AREAS AS REQUIRED TO RETURN THEM TO THEIR ORIGINAL CONDITION.
B.
VERIFY EXTENT OF DEMOLITION WORK WITH INFORMATION SHOWN IN THE
DRAWINGS, AND WORK THAT IS NOT SHOWN AND MAY BE REQUIRED TO COMPLETE
THE INTENDED WORK.
C.
ALL WORK SHALL COMPLY WITH REQUIRED LOCAL CODES. CONTRACTOR IS
RESPONSIBLE FOR OBTAINING REQUIRED PERMITS AND INSPECTIONS FOR ALL
WORK ASSOCIATED WITH THIS CONTRACT.
D.
CONTRACTOR SHALL REPAIR ALL DISTURBED AREAS AS REQUIRED TO MATCH
SURROUNDING EXISTING FINISHES NOT DISTURBED.
E.
TYPES OF FLOOR, WALL, AND CEILING FINISHES INDICATED FOR REMOVAL BY
DEMOLITION NOTES IS FOR GENERAL INFORMATION ONLY FROM INFORMATION OBTAINED
FROM EXISTING PLANS AND OBSERVATIONS. CONTRACTOR SHALL FIELD VERIFY
MATERIAL TYPES ONSITE PRIOR TO BID AND INCLUDE NECESSARY WORK IN HIS BID.
F.
ALL AUTOMATIC DOOR OPERATORS, ACCESS CONTROL & DOOR HARDWARE,
APPLIANCES, FURNITURE, AND EQUIPMENT TO REMAIN THE PROPERTY OF THE
OWNER - CONTRACTOR TO COORDINATE REMOVAL, RELOCATION, STORAGE OF
EQUIPMENT FROM DEMO AREAS WITH OWNER.
G.
PATCH FLOOR AT REMOVED WALLS AND CASEWORK PREPARE FLOOR TO RECEIVE
NEW FLOORING AS REQUIRED.
H.
PATCH ALL HOLES IN EXISTING SLAB LEFT FROM REMOVAL OF FIXTURES.I.
REMOVE ALL WALL PROTECTION CAREFULLY AND RETURN TO OWNER.J.
CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL MATERIAL IN A LEGAL MANNER
NOT SCHEDULED FOR REUSE UNDER THIS PROJECT.
K.
IN ALL WALLS AND CEILINGS THAT ARE TO BE REMOVED THE CONTRACTOR SHALL
BE RESPONSIBLE FOR DISCONNECTING AT SOURCE AND REMOVING OR CAPPING
ELECTRICAL, PLUMBING, GAS LINES AND MECHANICAL DUCTWORK THAT IS
DISCLOSE AND NOT SCHEDULED FOR REUSE. CONTRACTOR SHALL REROUTE AND
CONTINUE ANY SYSTEM THAT MUST BE RETAINED FOR NEW CONSTRUCTION.
L.
ALL ELECTRICAL CIRCUITS FOR EQUIPMENT THAT IS TO BE REMOVED SHALL BE
DISCONNECTED AT SOURCE AND REMOVED.
M.
ALL PIPING GAS, WATER SUPPLY, VENT, DRAIN LINES, ETC. SUPPLYING EQUIPMENT
THAT IS TO BE REMOVED SHALL BE DISCONNECTED, REMOVED AND CAPPED
ABOVE CEILING OR BELOW FLOOR. CONTRACTOR SHALL REROUTE AS NECESSARY,
TO BE BEHIND NEW CONSTRUCTION. (PATCH FLOOR BACK PRIOR TO TOPPING.)
N.
ALL MED GASES AND PLUMBING TO BE REMOVED AT WALLS SCHEDULED FOR
DEMOLITION.
O.
REMOVE ALL PLUMBING FIXTURES AND EQUIPMENT WITHIN ROOMS SCHEDULED TO
BE DEMOLISHED. SEE MEP PIPING DRAWINGS.
P.
RETURN ALL SIGNAGE AFFECTED BY CONSTRUCTION TO OWNER.Q.
CONTRACTOR TO COORDINATE INFECTIOUS CONTROL REQUIREMENTS WITH
OWNER PRIOR TO ANY CONSTRUCTION.
R.
REMOVE ALL WINDOW TREATMENTS AND HARDWARE.S.
REMOVE ALL CUBICLE CURTAINS AND ASSOCIATED TRACKS IN AREAS TO BE REMODELED
AND RETURN TO OWNER.
T.
REMOVE ALL WALL-MOUNTED COMPUTER DESKS, MONITORS, ETC. AND RETAIN
FOR REINSTALLATION PER EQUIPMENT PLANS.
U.
REMOVE ALL AUTOMATIC DOOR OPERATOR HARDWARE WITHIN THE PROJECT
AREA AND RETURN TO THE VA.
V.
Drawing Title Project Title
Date
Location
Checked
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
589A7-17-203
Robert J. Dole VA Medical Center
RENOVATE WARDS FOR PATIENT
PRIVACY PHASE 1, B1
117 PIERCE ST, SUITE 110
SIOUX CITY, IOWA
142 N. MOSELY ST
WICHITA, KANSAS FINAL CONSTRUCTION DOCUMENTS
AD-102.3
3RD FLOOR DEMOLITION BID ITEM 3
Wichita, Kansas
DCW RMC04-27-2018
1/8" = 1'-0"1
PARTIAL 3RD FLOOR - DEMO PLAN BID ITEM 3
1/8" = 1'-0"2
PARTIAL 3RD FLOOR - CEILING DEMO PLAN BID ITEM 3
N 4' 8' 16'
1/8" = 1'-0"
0'
N 8' 16' 32'
1/16" = 1'-0"
0'
BID ITEM 3
SEE SPECIFICATION SECTION 01 00 00
FOR FIELD VERIFICATION OF EXISTING
CONCRETE COLUMN, BEAM, AND JOIST LOCATIONS.
No. Description Date
SEE SPECIFICATION SECTION 01 00 00
FOR FIELD VERIFICATION OF EXISTING
CONCRETE COLUMN, BEAM, AND JOIST LOCATIONS.
SEE SPECIFICATION SECTION 01 00 00
FOR MANOMETER REQUIREMENTS AT EACH FLOOR
DURING CONSTRUCTION ACTIVITIES.
SEE SPECIFICATION SECTION 01 35 26 FOR
INFECTION CONTROL REQUIREMENTS FOR THIS
PROJECT.
REQUIREMENTS INCLUDE, BUT ARE NOT LIMITED
TO CONSTRUCTION PARTITIONS, NEGATIVE AIR
PRESSURE WITHIN CONSTRUCTION AREAS, AND
NOT IN
SCOPE OF
WORK
NOT IN
SCOPE OF
WORK
NOTE:
ALSO REF. MEP DRAWINGS FOR
SCOPE OF DEMOLITION.
THIS SHADED AREA REPRESENTS THE
APPROXIMATE CEILING AREA TO BE
PRESERVED IN THIS BID ITEM.
(ALL PATIENT ROOMS AND SUPPORTINGS
SPACES IN THE WEST WING OF 3RD FLOOR.
SEE SPECIFICATIONS AND ALSO
NARRATIVE ON G-105.
PATIENT LIFT AND CUBICLE CURTAIN
TRACKS TO REMAIN IN PATIENT ROOMS
WITHIN SHADED AREA.
SEE BID ITEM 1 FOR DEMOLITION
NOTES FOR THIS AREA (UN-SHADED)
UP
DN
NOT IN
SCOPE OF
WORK
NOT IN
SCOPE OF
WORK
ALSO REF. MEP DRAWINGS FOR
SCOPE OF DEMOLITION.
PROTECT EXISTING STRUCTURE
FROM DAMAGE. TYPICAL FOR ALL
LOCATIONS.
THIS SHADED AREA REPRESENTS THE
APPROXIMATE AREA TO BE
PRESERVED IN THIS BID ITEM
(ALL PATIENT ROOMS AND SUPPORTINGS
SPACES IN THE WEST WING OF 3RD FLOOR.
SEE SPECIFICATIONS AND ALSO
NARRATIVE ON G-105.
RE-BUILDING OF CHASE REMAIN
IN PROJECT IN THIS BID ITEM
SEE BID ITEM 1 FOR DEMOLITION
NOTES FOR THIS AREA (UN-SHADED)
BID ITEM 4 - AREAS AFFECTED
CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO WORK BEGINNING.
THE CONTRACTOR IS RESPONSIBLE FOR INFORMING THE COR OF ANY CONDITIONS
THAT DIFFER FROM THE INFORMATION INDICATED IN THE DRAWINGS.
A.
GENERAL DEMOLITION NOTES:
PROTECT ALL EXISTING BUILDING COMPONENTS WHICH ARE TO REMAIN. REPAIR ANY
DAMAGED AREAS AS REQUIRED TO RETURN THEM TO THEIR ORIGINAL CONDITION.
B.
VERIFY EXTENT OF DEMOLITION WORK WITH INFORMATION SHOWN IN THE
DRAWINGS, AND WORK THAT IS NOT SHOWN AND MAY BE REQUIRED TO COMPLETE
THE INTENDED WORK.
C.
ALL WORK SHALL COMPLY WITH REQUIRED LOCAL CODES. CONTRACTOR IS
RESPONSIBLE FOR OBTAINING REQUIRED PERMITS AND INSPECTIONS FOR ALL
WORK ASSOCIATED WITH THIS CONTRACT.
D.
CONTRACTOR SHALL REPAIR ALL DISTURBED AREAS AS REQUIRED TO MATCH
SURROUNDING EXISTING FINISHES NOT DISTURBED.
E.
TYPES OF FLOOR, WALL, AND CEILING FINISHES INDICATED FOR REMOVAL BY
DEMOLITION NOTES IS FOR GENERAL INFORMATION ONLY FROM INFORMATION OBTAINED
FROM EXISTING PLANS AND OBSERVATIONS. CONTRACTOR SHALL FIELD VERIFY
MATERIAL TYPES ONSITE PRIOR TO BID AND INCLUDE NECESSARY WORK IN HIS BID.
F.
ALL AUTOMATIC DOOR OPERATORS, ACCESS CONTROL & DOOR HARDWARE,
APPLIANCES, FURNITURE, AND EQUIPMENT TO REMAIN THE PROPERTY OF THE
OWNER - CONTRACTOR TO COORDINATE REMOVAL, RELOCATION, STORAGE OF
EQUIPMENT FROM DEMO AREAS WITH OWNER.
G.
PATCH FLOOR AT REMOVED WALLS AND CASEWORK PREPARE FLOOR TO RECEIVE
NEW FLOORING AS REQUIRED.
H.
PATCH ALL HOLES IN EXISTING SLAB LEFT FROM REMOVAL OF FIXTURES.I.
REMOVE ALL WALL PROTECTION CAREFULLY AND RETURN TO OWNER.J.
CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL MATERIAL IN A LEGAL MANNER
NOT SCHEDULED FOR REUSE UNDER THIS PROJECT.
K.
IN ALL WALLS AND CEILINGS THAT ARE TO BE REMOVED THE CONTRACTOR SHALL
BE RESPONSIBLE FOR DISCONNECTING AT SOURCE AND REMOVING OR CAPPING
ELECTRICAL, PLUMBING, GAS LINES AND MECHANICAL DUCTWORK THAT IS
DISCLOSE AND NOT SCHEDULED FOR REUSE. CONTRACTOR SHALL REROUTE AND
CONTINUE ANY SYSTEM THAT MUST BE RETAINED FOR NEW CONSTRUCTION.
L.
ALL ELECTRICAL CIRCUITS FOR EQUIPMENT THAT IS TO BE REMOVED SHALL BE
DISCONNECTED AT SOURCE AND REMOVED.
M.
ALL PIPING GAS, WATER SUPPLY, VENT, DRAIN LINES, ETC. SUPPLYING EQUIPMENT
THAT IS TO BE REMOVED SHALL BE DISCONNECTED, REMOVED AND CAPPED
ABOVE CEILING OR BELOW FLOOR. CONTRACTOR SHALL REROUTE AS NECESSARY,
TO BE BEHIND NEW CONSTRUCTION. (PATCH FLOOR BACK PRIOR TO TOPPING.)
N.
ALL MED GASES AND PLUMBING TO BE REMOVED AT WALLS SCHEDULED FOR
DEMOLITION.
O.
REMOVE ALL PLUMBING FIXTURES AND EQUIPMENT WITHIN ROOMS SCHEDULED TO
BE DEMOLISHED. SEE MEP PIPING DRAWINGS.
P.
RETURN ALL SIGNAGE AFFECTED BY CONSTRUCTION TO OWNER.Q.
CONTRACTOR TO COORDINATE INFECTIOUS CONTROL REQUIREMENTS WITH
OWNER PRIOR TO ANY CONSTRUCTION.
R.
REMOVE ALL WINDOW TREATMENTS AND HARDWARE.S.
REMOVE ALL CUBICLE CURTAINS AND ASSOCIATED TRACKS IN AREAS TO BE REMODELED
AND RETURN TO OWNER.
T.
REMOVE ALL WALL-MOUNTED COMPUTER DESKS, MONITORS, ETC. AND RETAIN
FOR REINSTALLATION PER EQUIPMENT PLANS.
U.
REMOVE ALL AUTOMATIC DOOR OPERATOR HARDWARE WITHIN THE PROJECT
AREA AND RETURN TO THE VA.
V.
Drawing Title Project Title
Date
Location
Checked
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
589A7-17-203
Robert J. Dole VA Medical Center
RENOVATE WARDS FOR PATIENT
PRIVACY PHASE 1, B1
117 PIERCE ST, SUITE 110
SIOUX CITY, IOWA
142 N. MOSELY ST
WICHITA, KANSAS FINAL CONSTRUCTION DOCUMENTS
AD-102.4
3RD FLOOR DEMOLITION BID ITEM 4
Wichita, Kansas
DCW RMC04-27-2018
N 4' 8' 16'
1/8" = 1'-0"
0'
N 8' 16' 32'
1/16" = 1'-0"
0'
1/8" = 1'-0"1
PARTIAL 3RD FLOOR - CEILING DEMO PLAN BID ITEM 4
1/8" = 1'-0"2
PARTIAL 3RD FLOOR - DEMO PLAN BID ITEM 4
BID ITEM 4
SEE SPECIFICATION SECTION 01 00 00
FOR FIELD VERIFICATION OF EXISTING
CONCRETE COLUMN, BEAM, AND JOIST LOCATIONS.
No. Description Date
SEE SPECIFICATION SECTION 01 00 00
FOR FIELD VERIFICATION OF EXISTING
CONCRETE COLUMN, BEAM, AND JOIST LOCATIONS.
SEE SPECIFICATION SECTION 01 00 00
FOR MANOMETER REQUIREMENTS AT EACH FLOOR
DURING CONSTRUCTION ACTIVITIES.
SEE SPECIFICATION SECTION 01 35 26 FOR
INFECTION CONTROL REQUIREMENTS FOR THIS
PROJECT.
REQUIREMENTS INCLUDE, BUT ARE NOT LIMITED
TO CONSTRUCTION PARTITIONS, NEGATIVE AIR
PRESSURE WITHIN CONSTRUCTION AREAS, AND
WALL MATERIALS
LEGEND FOR WALL TAGS
MATERIAL
WIDTH
L - LIGHT GAUGE METAL STUDS, 25 ga. (REF. SPECS.)
WALL WIDTHS
0 - 5/8" GYP. BD.
1 - 1 5/8" HAT CHANNEL/ STUDS
2 - 2 1/2" METAL STUD/SHAFT WALL FRAMING
(SHAFT WALL WHERE NOTED AS FIRE RATED)
3 - 3 5/8" METAL STUD FRAMING
4 - 4" SHAFT WALL STUD FRAMING
NOTES:
PROVIDE ACCOUSTICAL SEALANT AT TOP & BOTTOM AND ALL
PENETRATIONS OF WALLS WITH SOUND BATT.
ALL STUD FRAMING TO BE 16" O.C., TYP.
PROVIDE CEMENTIOUS BACKER BOARD AT ALL SHOWER & WET
AREAS AND AS BACKER FOR CERAMIC WALL TILE. TOILET & SINK
AREAS TO RECEIVE MOISTURE-RESISTANT GYP BOARD.
PROVIDE SEALANT AT TOP & BOTTOM AND ALL PENETRATIONS OF
SMOKE PARTITION WALLS AS REQUIRED BY CODE.
PROVIDE ALL NEW WALLS THAT GO TO STRUCTURE w/ 1 1/2"
MTL. DEFLECTION TRACK
N - NONE
A - ACC0USTICAL
XXXC
INSULATION
WALL INSULATION
WALL HEIGHT
SHADED WALLS INDICATES WALLS
THAT EXTEND TO DECK
INSTALL 5/8" TYPE X GYP BD ON ONE SIDE OF FURRING,
TYP. INSTALL 5/8" TYPE X GYP BD ON BOTH SIDES OF
STUD FRAMING, TYP., UNLESS NOTED OTHERWISE.
EXTEND GYP BD TO 6" ABOVE CEILING UNLESS
REQUIRED OTHERWISE. PROVIDE ACCOUSTICAL
SEALANT AT TOP AND BOTTOM OF ALL PENETRATIONS
OF WALL WITH SOUND BATT.
WALLS TO RECEIVE GYPSUM BOARD PRODUCT ON BOTH
FACES OF METAL STUD AND WALLS THAT REQUIRE
ACOUSTICAL SOUND BATT INSULATION SHALL BE
CONSTRUCTED TO MEET A MINIMUM 45 STC UNLESS
OTHERWISE NOTED.
FIRE TAPE AND/OR FILL VOIDS AT TOP OF WALL - FIRE
RATED WALL AS REQUIRED BY CODE - REF. SPEC.
PROVIDE SEALANT AT TOP & BOTTOM AND ALL
PENETRATIONS ON ONE SIDE OF SMOKE PARTITION
WALLS AS REQUIRED BY CODE - REF. SPECS
INSTALL FIRE RATED SEAL/CLOSURE @ ALL OPENINGS,
GAPS AND TOP & BOTTOM OF FRAMING AS SPECIFIED.
BRACE ALL STUD WALLS TO STRUCTURE ABOVE @ 4'-0" O.C.
OR EXTEND ALL STUDS TO DECK ABOVE, TYP.
T - THERMAL
REF CODE SHEET
G - GYP. BD. ATTACH TO FACE OF EXISTING (SHIM AS
REQD.)
DN
UP
PATIENT
ROOM
221-1
TOILET
220-1
SOILED
UTILITY
218-1
TOILET
217-1
PATIENT
ROOM
216-1
AIRBORNE
INFECTION
ISO.
PATIENT
ROOM
214-1
TOILET
213-1
PATIENT
ROOM
211-1
TOILET
209-1
PATIENT
ROOM
208-1
PATIENT
ROOM
204-1
BARIATRIC
PATIENT
ROOM
202-1
PATIENT
ROOM
233-1
PATIENT
ROOM
234-1 PATIENT
ROOM
236-1
TOILET
232-1
ANTE RM
215-1
CHARTING
206-1
TOILET
238-1
NURSE
STATION
224-1
EXIST.
STAIRS
2-STAIR-W
TOILET
210-1
TOILET
203-1
TOILET
205-1
CORR
200-1
CORR
201-1
CORR
225-1CORR
212-1
CORR
219-1
CORR
207-1
STAFF
TOILET
222-1
HSKPG
240-1
221-1
220-1
218-1
216-1
215-1214-1
213-1
222-1
211-1
210-1
209-1
208-1
202-1
203-1
204-1
205-1
232-1
231-1
233-1
236-1
NOT IN
SCOPE OF
WORK
NOT IN
SCOPE OF
WORK
1' - 6" 8' - 10" 18' - 3" 4"
/2
4"
19' - 2"
4" 7' - 9" 1' - 3" 8' - 1" 2' - 1" 8' - 2"
19' - 8"
4"
4"
19' - 10"
1' - 0" 12' - 0"
4"
4"
12' - 0" 7' - 2" 8' - 2" 2' - 1" 17' - 7" ± 4"
8' - 11 1/2"
M
IN
C
L E
A R
7' - 0 1/2"
L3A
L2N
L3A
L2N
L2NL3T
L3A
L3A
L3A
L3A
L2N
L2N
L3A
L2N
L3N
L2N
L3A
L3A
L3A
L2N
G0N
L3T
L3A
L3A
L3A
L2A
L2N
L2N
G0N
L3A
L2N
L2NG0N
L3A
L3A
L3A
M
IN
C
L E
A R
5' - 5 1/4"
L3T
L3A L3N
L3AC
L3A
L3AC
L3AC
L2N
L3T
G0N
L3AC
L3AC
L2N
L3N
L2N
G0N
L3AC
L3AC L3A
L3A
L3AC
M
IN
C
L E
A R
L3A
L3A
G0N
L3AC
L2N
L2N
L2N
G0N
L2N
G0NG0NG0N
L2N
L2N
L2N
L2N
L3A
L2N
L3T
L3AC
G0N
L3T L1N L3T
L1N
L3T
L3T
L3T
L3TL3T
L3T
L3T
L3T
L3T
L3TL3A L3T
L3A
L3T
L3T
L3T
L3T
L3T G0N
L2N
L2N
L2N
L2N
G0N
5' - 5" * 4"
L3A
L3T
L3A L3T
L3N
L3T
L3T
L3A
L3T
L3A
L2N
L2N
L1N
L2NL3A
L3A
L3T
L3A
L3A
L3A
L3A
L3A
8'-0" MIN. CLEAR
4"
4' - 11 1/4"
L3AC
L3AC
L3AC
L3AC
L3AC
L3AC
L3A
L3AL2N
L3A
L2N
L2NL3A
L3T
L3T
L3T
L3AL3T
L3A
L3A
L3A
L3A
L3A L3A
L2N
L2NL3A
L3A L3A
L3A L3A
L3A
L3A
L3A
L3A
G0N
L3T
G0N
L3T
L2N
1' - 0"
/4
2' - 5"
1L3A L3A L1N
L3AL2N
L2N
L3T
L3A
L3T
L3A
L3A
L2N
L3A
L2N
L3A
L3A
3' - 2"
4" 2' - 10"
L3A
L3A L3A
L3N
L3A L3N
L3T
G0N
L3T
L3T
L3T
L3T
L3T
L3AL3A
L2N
L2N
L3T G0N
G0N 1
L3A
L3T
2 2
5' - 5" * 3' - 5"
/1
8'
8'-0" MIN. CLEAR
/4
3' - 11 1/4"
7' - 1"
/4
12' - 5" 4"
L3A L3A
L3A
L3N
L3N
L3A
L3A
L3A
L3A
L3A
L3A
L3AL3A
L3N
L3A
L3A
L3T
L3T
L2N L3T
L3T
L3T
1 1
L1N
L1N
SHAFT
CUBICLE
CURTAIN &
TRACK
(CCT)
AI-301
AI-301
AI-301 4
AI-30116
AI-303
AI-303
AI-303 8
AI-303 AI-303
AI-303
AI-303 27
L3TL3T
L3A
RECEPTION
241-1
ELECT.
228-1
EQUIP.
STOR.
229-1
NOURISH.
227-1
MEDICATION
230-1
CLEAN
UTILITY
231-1
L4AC
L4AC
L3N
L3N
228-1
229-1
230-1
240-1
238-1
L3A L3A
EXISTING CLOSET
TO REMAIN
L2N
L2N
L2N
L3A
L3A
L3A
L3N
L3A
L2N
L3A
L3AC
L3AC
L3AC
L2AC
L2AC
L3A
L3A
L2N
ALCOVE
201A-1
L3AC
AI-3015
AI-301
AI-302
5 AI-3028
AI-301
G0N
L2N
G0N
L2N
CLEAN
LINEN
201B-1
AS-101
L3T
L3T
AS-101
AS-101
Sim
L3A
E X
IS
T
D
O O
R T
O R
E M
A
IN
E X
IS
T
D
O O
R T
O R
E M
A
IN
EXIST. DOOR
TO REMAIN
EXIST. DOOR
TO REMAIN
217-1
E X
IS
T
D
O O
R T
O R
E M
A
IN
AI-302
AI-301 12
AS-3012
AI-303
AI-303
AI-302 16
AS-101
/4
7' - 11" 6' - 0" 11' - 3" ± 4"12' - 6" 3' - 11" 5' - 5" *
2' - 6"
/2
ALL
REV
5' - 5" * 3' - 5"7' - 10" 1' - 3"
L3N
L3AC
L3A
L3A
G0N
G0N G0N
AI-303 7
AI-303
3 3
3 3
3 3
L3A
L3A
L3A
AI-30111
AI-301
FLOOR PENETRATION IS EXISTING.
EXIST. CHASE/SHAFT WALLS TO
BE DEMOLISHED AND REBUILT
AFTER NEW MEP WORK IS IN
PLACE.
TOILET
235-1
L3A
L3A
L3N
235-1
L3A
L3A
5' - 5" *
AI-303
L3AC
L3A
L3A
AI-301
TOILET
237-1
L2N
L3AAI-303
L3N
L3N
L3N
L3N
234-1
L3N
L3N
AI-301 2
3' - 0 1/2"
TYP.
AS-101
TYP.
G0N
L3N
AI-3018
AI-301 8
AI-301
AI-301
AI-301 8
AI-301
AI-3012
AI-301
AI-301
AI-301
AI-301
AI-301
207-1
L3A
NOT IN
SCOPE OF
WORK
3' - 4" 4' - 1" 2' - 10"
2' - 1" 8' - 2" 1' - 4 1/2"
3' - 8 1/2"
/2
/2
/2
/2
/2
7' - 2 1/2"
3' - 8" 3' - 6 1/2"
8"
14' - 9" 1' - 6 1/2"
11' - 5 1/2"
/2
/2
1' - 3"
2' - 11"7' - 5"2' - 3" 5' - 7"8' - 3"6' - 10"
L3N
6' - 10"
L3A
1' - 2"
/2
3' - 6" 2' - 11"
8' - 7 1/2" 8' - 6" 3' - 1 1/2" 11' - 7 1/2"
8' - 2 1/2"
4 4
4 4
1' - 6" 5' - 4" 1' - 6" 1' - 8"
5' - 2 1/2" 1' - 6" 5' - 4" 1' - 6"
/2
4 1/2" 1' - 6" 5' - 4" 1' - 6"
11 1/2"
1' - 6"
5' - 4" 1' - 6"
1' - 6" 5' - 4" 1' - 6" 1' - 10 1/2"
7 1/2" 1' - 6" 6' - 4" 1' - 6" 8 1/2"
/2
CUBICLE
CURTAIN &
TRACK
(CCT)
CUBICLE
CURTAIN &
TRACK
(CCT)
CUBICLE
CURTAIN &
TRACK
(CCT)
CUBICLE
CURTAIN &
TRACK
(CCT)
CUBICLE
CURTAIN &
TRACK
(CCT)
CUBICLE
CURTAIN &
TRACK
(CCT) CUBICLE
CURTAIN &
TRACK
(CCT)
CUBICLE
CURTAIN &
TRACK
(CCT)
AS-301
AS-301 3
AI-303
11' - 1 1/2"6' - 1 1/2" 5' - 5 1/2" 6' - 7 1/2" 5' - 5"
1' - 4 1/2"
5 6
5 6
5 6
5 6
5 6
5 6
5 6
5 6
5 6
M
IN
C
L E
A R
8'-0" MIN. CLEAR
235-8 1' - 6" 7' - 7 1/2"
1' - 3 1/2"
AS-101
TYP.
AI-105
AI-105
FLOOR SLOPING TYPE A
- SEE TOILET 335-1.
FLOOR SLOPING TYPE A
- SEE TOILET 335-1.
FLOOR SLOPING TYPE A
- SEE TOILET 335-1.
FLOOR SLOPING TYPE A
- SEE TOILET 335-1.
FLOOR SLOPING TYPE A
- SEE TOILET 335-1.
FLOOR SLOPING TYPE B
- SEE TOILET 321-1.
TYPICAL FLOOR SLOPING
- TYPE C
TYPICAL FLOOR SLOPING
- TYPE E
FLOOR SLOPING TYPE F
- SEE TOILET 303-1.
L3T
LEVEL
L3N
L3N
L3N
L3A L3A
L3A
L3A L3A
L3A
L3A
L3A
L3A
L3A
L3A
G0N
L3A
CLOSET
207A-1
PHASE 1 PROJECT
N
KEY PLAN - 2ND FLOOR
1" = 60'-0"
NEW 5/8" GYP. BD. ON
METAL STUDS
NEW 5/8" GYP. BD. (TYP.)
- ALLOW FOR MIN. 1/4" GAP ALONG
EXISTING COLUMN FACE
EXIST. CONCRETE
COLUMN
NOTE: SEE FLOOR PLANS FOR WALL TYPES AT EXIST. COLUMNS
EXIST. DOOR
AND FRAME
NEW 5/8" GYP. BD.
NEW 5/8" GYP. BD.
ON METAL STUD PARTITIONS
SEAL JOINT BETWEEN
GYP. BD. AND EXIST.
DOOR FRAME (JAMB & HEAD)
5/8" GYP. BD. ON 3 5/8" METAL
STUD PARTITION
- SEE SPECS
R15 THERMAL
BATT INSULATION
- SEE SPECS
MAINTAIN 3/8" GAP BETWEEN
EXISTING INSIDE FACE OF WALL
AND NEW STUD PARTITION
EXISTING PERIMETER/EXTERIOR
WALL TO REMAIN
SLIP TRACK WHERE NEW INTERIOR
FURRING MEETS STRUCTURE.
EXIST. RM.
CHASE
FLOOR PENETRATION IS EXISTING.
EXIST. CHASE WALLS TO BE
DEMOLISHED AND REBUILT AFTER
NEW MEP WORK IS IN PLACE.
L4AC
L4AC
L4AC
NEW PARTITIONS TO ALIGN WITH
EXISTING WALLS TO REMAIN
WHERE APPLICABLE.
EXIST. RM.
EXIST. CORR.
5/8" GYP. BD. ON 3 5/8" METAL
STUD PARTITION
- SEE SPECS
SLIP TRACK WHERE NEW INTERIOR
FURRING MEETS STRUCTURE.
ACOUSTIC ATTENUATION
BATT INSULATION
- WHERE SCHEDULED
- SEE SPECS
ACOUSTIC SEALENT AT
SILL TRACK
- WHERE ACOUSTIC BATTS
SCHEDULED
- SEE SPECS
3 5/8"
Drawing Title Project Title
Date
Location
Checked
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
589A7-17-203
Robert J. Dole VA Medical Center
RENOVATE WARDS FOR PATIENT
PRIVACY PHASE 1, B1
117 PIERCE ST, SUITE 110
SIOUX CITY, IOWA
142 N. MOSELY ST
WICHITA, KANSAS FINAL CONSTRUCTION DOCUMENTS
AS-101
1ST & 2ND FLOOR ARCH. PLANS
Wichita, Kansas
DCW RMC04-27-2018
N 2' 4' 8'0'
1/4" = 1'-0" 1/4" = 1'-0"1
2ND FLOOR - ARCHITECTURAL PLAN
PLAN NOTES - FLOOR PLAN
1 NEW METAL STUD WALL / GYP. BOARD TO BUTT TO EXISTING STRUCTURE. ALSO SEE DETAIL 2/AS-101.
2 PROVIDE BLACK-OUT FILM AT INTERIOR SIDE OF WINDOW PRIOR TO NEW WALL CONSTRUCTION REF.
SPECS.
3 PROTECT EXISTING STRUCTURE FROM DAMAGE. TYPICAL FOR ALL LOCATIONS.
4 EXISTING STEAM PIPING LOCATION (ALSO SEE MEP DRAWINGS). ENCAPSULATE WITHIN WALL FURRING.
NOTIFY C.O.R. IF ACTUAL PIPING LOCATIONS AFFECT PLANNED WALL LAYOUT.
5 VERIFY EXISTING FLOOR STRUCTURE BELOW PLUMBING. FLOOR PENETRATION CAN NOT BE THROUGH
CONCRETE BEAMS OR JOISTS.
6 VERIFY PLUMBING CHASE SPACE REQUIREMENTS.
7 NEW SOLID SURFACE WINDOW STOOL AT EXISTING WINDOW. REF. SPECS & CASEWORK DRAWINGS.
1" = 1'-0"4
TYP. COLUMN FURRING
1" = 1'-0"3
TYP. FURRING AT EXIST. DOOR
1" = 1'-0"6
TYP. PERIMETER FURRING
1/4" = 1'-0"2
1ST FLOOR - ARCHITECTURAL PLAN
N 2' 4' 8'0'
1/4" = 1'-0"
1" = 1'-0"5
TYP. INTERIOR PARTITION
SEE SPECIFICATION SECTION 01 00 00
FOR FIELD VERIFICATION OF EXISTING
CONCRETE COLUMN, BEAM, AND JOIST LOCATIONS.
NOTIFY THE C.O.R. OF ANY CONFLICTS BETWEEN
CONCRETE STRUCTURE (COLUMNS, BEAMS, OR
JOISTS) AND NEW DESIGN ELEMENTS BEFORE
COMMENCEMENT OF NEW CONSTRUCTION OF
EACH PHASE.
No. Description Date
1" = 1'-0"7
TYP. HEADWALL PILASTER
5/8" GYP. BD.
3 5/8" METAL
STUDS
ACOUSTIC
ATTENUATION BATT
INSULATION
TWO AT EACH PATIENT ROOM (AT ROOM HEADWALL)
WALL MATERIALS
LEGEND FOR WALL TAGS
MATERIAL
WIDTH
L - LIGHT GAUGE METAL STUDS, 25 ga. (REF. SPECS.)
WALL WIDTHS
0 - 5/8" GYP. BD.
1 - 1 5/8" HAT CHANNEL/ STUDS
2 - 2 1/2" METAL STUD/SHAFT WALL FRAMING
(SHAFT WALL WHERE NOTED AS FIRE RATED)
3 - 3 5/8" METAL STUD FRAMING
4 - 4" SHAFT WALL STUD FRAMING
NOTES:
PROVIDE ACCOUSTICAL SEALANT AT TOP & BOTTOM AND ALL
PENETRATIONS OF WALLS WITH SOUND BATT.
ALL STUD FRAMING TO BE 16" O.C., TYP.
PROVIDE CEMENTIOUS BACKER BOARD AT ALL SHOWER & WET
AREAS AND AS BACKER FOR CERAMIC WALL TILE. TOILET & SINK
AREAS TO RECEIVE MOISTURE-RESISTANT GYP BOARD.
PROVIDE SEALANT AT TOP & BOTTOM AND ALL PENETRATIONS OF
SMOKE PARTITION WALLS AS REQUIRED BY CODE.
PROVIDE ALL NEW WALLS THAT GO TO STRUCTURE w/ 1 1/2"
MTL. DEFLECTION TRACK
N - NONE
A - ACC0USTICAL
XXXC
INSULATION
WALL INSULATION
WALL HEIGHT
SHADED WALLS INDICATES WALLS
THAT EXTEND TO DECK
INSTALL 5/8" TYPE X GYP BD ON ONE SIDE OF FURRING,
TYP. INSTALL 5/8" TYPE X GYP BD ON BOTH SIDES OF
STUD FRAMING, TYP., UNLESS NOTED OTHERWISE.
EXTEND GYP BD TO 6" ABOVE CEILING UNLESS
REQUIRED OTHERWISE. PROVIDE ACCOUSTICAL
SEALANT AT TOP AND BOTTOM OF ALL PENETRATIONS
OF WALL WITH SOUND BATT.
WALLS TO RECEIVE GYPSUM BOARD PRODUCT ON BOTH
FACES OF METAL STUD AND WALLS THAT REQUIRE
ACOUSTICAL SOUND BATT INSULATION SHALL BE
CONSTRUCTED TO MEET A MINIMUM 45 STC UNLESS
OTHERWISE NOTED.
FIRE TAPE AND/OR FILL VOIDS AT TOP OF WALL - FIRE
RATED WALL AS REQUIRED BY CODE - REF. SPEC.
PROVIDE SEALANT AT TOP & BOTTOM AND ALL
PENETRATIONS ON ONE SIDE OF SMOKE PARTITION
WALLS AS REQUIRED BY CODE - REF. SPECS
INSTALL FIRE RATED SEAL/CLOSURE @ ALL OPENINGS,
GAPS AND TOP & BOTTOM OF FRAMING AS SPECIFIED.
BRACE ALL STUD WALLS TO STRUCTURE ABOVE @ 4'-0" O.C.
OR EXTEND ALL STUDS TO DECK ABOVE, TYP.
T - THERMAL
REF CODE SHEET
G - GYP. BD. ATTACH TO FACE OF EXISTING (SHIM AS
REQD.)
UP
DN
PATIENT
ROOM
336-1
EQUIP.
STOR.
338-1
EQUIP.
ALCOVE
300-1HALL
301-1
HALL
326-1
HALL
339-1
336-1
338-1
323-1
322-1
321-1
320-1
319-1
317-1
316-1
314-1
313-1
311-1
310-1
309-1
308-1
302-1
303-1
304-1
305-1
NOT IN
SCOPE OF
WORK
NOT IN
SCOPE OF
WORK
C
L E
A N
M
IN
2' - 6" 12' - 11"
7' - 7 1/2" 5' - 5 1/2"
6' - 4 1/2"
/4
/8
8' - 2" 7' - 2 3/8" 3"
4" 12' - 6" 3' - 11" 5' - 5" 11' - 3"
4"
5' - 5" * 4"
8'-0" MIN. CLEAR
6' - 0"
8" 16' - 9" 2' - 1" 8' - 2" 2' - 1"
3' - 8"
4"
19' - 10"
2 2 2
222 2 2
2 2
/2
/2
4" 8' - 0" 1' - 2"
7' - 11" 2' - 1" 8' - 2" 19' - 8" 4"
3' - 2"4" 2' - 10" 5
1 1
1 1
1' - 6" 8' - 10" 18' - 3" 4"
5' - 5" * 3' - 5"
8'-0" MIN. CLEAR
8'
3' - 11"
7' - 1"
/2
3' - 8"
12' - 4 3/8" 4"
L3T L3T L3T
L3AC
L3T
L2N
L3AC
L2N
L2N
L3AC
L3A
L2N
L2N
L3A
L3N
L2N
L3A
L3A
L3A
L3A
L3A
L2N
L2N
L3A
L2N
L2N
L2N
L3A
L3A
L3A
L3A
L2T
G0N
L3AC
L3TG0N L3TL2NL3T L2NL3TL1N
L3T G0NL3TG0NL3T
G0N
L3TG0N L3T L3TL3AG0N
L2N
L2N
L2N L2N
L3T
L3A
L3T
L3A
L3A
L3A
L3A
L3A
L3A
L3T
L3T
L3AL3N
L3A
L3T
L3A
L3A
L3T
L3T
G0N
L3A
L3A
L3A
L3A
L3A
L3T L3T
L3T
L3A
L3A
L3N
L3T
L3T
L3A L3A
L3A
L2N
L3A
L3N
L3A
L3A
L3A
L3A
L3A
L2N
L3A
L2N
L3A
L2N L3A
L3A
L3A L3A
L3A
L3N
L3A
L3A
L3A
L2N
L3A
L2N
L3A
L3A
L3AL3A
L3A
L1N
L3A
L3T
L3T
L3T
L3T
L3T
L3T
L3T
L3T
L3ACL3AC
L3A
L3A
L3A
L3AC
L3AC
L3AC
L3AC
L3T
L2N
L2N
L3AC
L2N
L2N L3AC
L3A
L3N
L3T
L3T
L3T
L3ACL3AC
L3AC
L3AC
L3A
L3A
L3A
L2N
L2N
L2N
L3N
L3A
L2N
L3A
L2N
L2N
L2N
G0N G0N
L2N
L1NL3A
L3N
L3A
318-1
L3A
L3T
L3A
L3A
EXIST.
STAIRS
3-STAIR-W
AS-301
AI-303
AI-303
AI-303
AI-303AI-303
AI-303
AI-303
AI-303
AI-303
AI-303
ELECT.
328-1
L4AC
L4AC
L4AC
L4AC
L4AC
L3A
L3A
L3A
328-1
7' - 7"
L3A
L3A L3T
L3A
L3AC
L3AC
L3AC
G0NG0N
L3N
AI-302
AS-101
Sim
L3AC
L3N
L3N
E X
IS
T
D
O O
R T
O R
E M
A
IN
EXIST. DOOR
TO REMAIN
AS-3015
AS-101
Sim
324-1
L3A
1' - 7 1/2"
/2
/2
7' - 4"
/2
AI-3038
ALL
REV
ALL
REV
3 3
3 3
3 3
5' - 6"
9' - 6 1/2"
5' - 10"
9' - 1" 10' - 9"
3' - 8" 3' - 6 1/2" 6' - 1 1/2"
L3T
17' - 7" 4"
/2
FLOOR PENETRATION IS
EXISTING. EXIST.
CHASE/SHAFT WALLS TO BE
DEMOLISHED AND REBUILT
AFTER NEW MEP WORK IS IN
PLACE.
337-1
AI-302 25
L2AC
L3A
L3A
L3A
L3AC
L3AC
L3AC
L3AC
L3T
L3N
L3N
L3N
AI-301 3AI-3014
AI-3015
AI-301 2
AI-301
AI-301
AI-30116 17
3' - 5" 5' - 5" *
CLEAN
UTILITY
330-1
TOILET
335-1
PATIENT
ROOM
334-1
SOILED
UTILITY
319-1
AIRBORNE
INFECTION
ISO.
PATIENT
ROOM
316-1
ANTE RM
318-1
TOILET
317-1
STORAGE
320-1
TOILET
321-1
PATIENT
RM
322-1
PATIENT
RM
314-1
STAFF
TOILET
323-1
TOILET
313-1
NURSE
STATION
325-1
PATIENT
RM
311-1
TOILET
310-1 TOILET
309-1
PATIENT
RM
308-1
HALL
307-1
BARIATRIC
PATIENT
ROOM
302-1
PATIENT
RM
304-1
CHARTING
306-1
TOILET
305-1
HSKPG
324-1
NOURISH.
327-1
CLOSET
307A-1
ALCOVE
301-1A
TOILET
337-1
HALL
312-1
AS-101
Sim
L3TL3TL3AC
EQUIP.
STOR.
329-1
MEDICATION
331-1
AI-3018
AI-301 8
AI-301 8
AI-3018
AI-301
AI-301
AI-301
AI-301 6
AI-301
AI-302 24
307-1
NOT IN
SCOPE OF
WORK
5 1/2" 1' - 6" 5' - 4" 1' - 6"
1' - 3 1/2" 1' - 6" 5' - 4" 1' - 6"
1' - 2" 1' - 6" 5' - 4" 1' - 6"
1' - 6" 5' - 4" 1' - 6" 2' - 1 1/2"
CUBICLE
CURTAIN &
TRACK
(CCT)
CUBICLE
CURTAIN &
TRACK
(CCT)
CUBICLE
CURTAIN &
TRACK
(CCT)
CUBICLE
CURTAIN &
TRACK
(CCT)
CUBICLE
CURTAIN &
TRACK
(CCT)
CUBICLE
CURTAIN &
TRACK
(CCT)
CUBICLE
CURTAIN &
TRACK
(CCT)
CUBICLE
CURTAIN &
TRACK
(CCT)
7 1/2" 1' - 6" 6' - 4" 1' - 6"
AI-301
AS-301 6
L3AC
L3AC
L3AC
L3AC
L3AC
L3AC
L3AC
L2AC
L3N
L3N 330-1
331-1
334-1
335-1
329-1
E X
IS
T
D
O O
R T
O R
E M
A
IN
L3N
L3N
L3N
G0N
L1N
L3A
L3A
L3A
L3A
L3A
L3AC
13' - 1" 7' - 0" 11' - 9" ±
15' - 2" ±8' - 8 1/2"8"7' - 11 1/2" ±
5' - 10"
4' - 3 1/2"
COORD. CHASE
DIMENSION WITH
MECH.
5' - 5" 3' - 4 1/2" 8' - 4 1/2"
/2
/2
6' - 9"
1' - 0"
AI-301
AI-302
L3A
AS-301
C
L E
A R
M
IN
AS-101
SimTYP.
L3A
L3A
3' - 0 1/2" 5' - 6" 6' - 6 1/2"
NOT IN
SCOPE OF
WORK
G0N
G0N
G0N
L3N
2' - 5"
2' - 4 1/2"
1' - 5"
AI-105
TYPICAL FLOOR SLOPING
- TYPE A
FLOOR SLOPING TYPE A
- SEE TOILET 335-1.
FLOOR SLOPING TYPE A
- SEE TOILET 335-1.
FLOOR SLOPING TYPE A
- SEE TOILET 335-1.
FLOOR SLOPING TYPE A
- SEE TOILET 335-1.
LEVEL
TYPICAL FLOOR SLOPING
- TYPE B
TYPICAL FLOOR SLOPING
- TYPE D
TYPICAL FLOOR SLOPING
- TYPE F
TOILET
303-1
SHAFT
L3N
L3N
L3N
L3N
L3A
L3A
LEVEL
PHASE 1 PROJECT
N
KEY PLAN - 3RD FLOOR
1" = 60'-0"
STEEL STUDS, 3 5/8" (MIN.),
20 GA. (MIN.), 24" o.c. (MAX.)
3 1/2" GLASS FIBER BATTS
5/8" GYP. BD., TYPE X
- BOTH SIDES OF PARTITION
JOINT COMPOUND APPLIED
IN TWO COATS WITH 2" TAPE.
AT EACH JOINT.
C-H STEEL STUDS
20 GA. (MIN.), 24" o.c. (MAX.)
GLASS FIBER BATTS
1" GYP. BD., TYPE X
JOINT COMPOUND APPLIED
IN TWO COATS WITH 2" TAPE.
AT EACH JOINT.
2 LAYERS, 5/8" GYP. BD., TYPE X
EXISTING CONCRETE
SLAB
3/16" STEEL PLATE FOR UP TO
12" DIAMETER HOLE REPAIR.
1/4" STEEL PLATE FOR LARGER
THAN 12" DIAMETER HOLE.
NEW CONCRETE FILL AT EXISTING
PENETRATION. SMOOTH TOP TO
BE FLUSH WITH FLOOR SLAB
3 1/2"3 1/2"
2 1/2" LENGTH CONCRETE
EPOXY SCREWS
OVERLAP, TYP.
5"
Drawing Title Project Title
Date
Location
Checked
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
589A7-17-203
Robert J. Dole VA Medical Center
RENOVATE WARDS FOR PATIENT
PRIVACY PHASE 1, B1
117 PIERCE ST, SUITE 110
SIOUX CITY, IOWA
142 N. MOSELY ST
WICHITA, KANSAS FINAL CONSTRUCTION DOCUMENTS
AS-102
3RD FLOOR ARCH. PLAN
Wichita, Kansas
DCW RMC04-27-2018
N 2' 4' 8'0'
1/4" = 1'-0" 1/4" = 1'-0"1
3RD FLOOR - ARCHITECTURAL PLAN
PLAN NOTES - FLOOR PLAN
1 NEW METAL STUD WALL / GYP. BOARD TO BUTT TO EXISTING STRUCTURE. ALSO SEE DETAIL 2/AS-101.
2 PROVIDE BLACK-OUT FILM AT INTERIOR SIDE OF WINDOW PRIOR TO NEW WALL CONSTRUCTION REF.
SPECS.
3 PROTECT EXISTING STRUCTURE FROM DAMAGE. TYPICAL FOR ALL LOCATIONS.
4 EXISTING STEAM PIPING LOCATION (ALSO SEE MEP DRAWINGS). ENCAPSULATE WITHIN WALL FURRING.
NOTIFY C.O.R. IF ACTUAL PIPING LOCATIONS AFFECT PLANNED WALL LAYOUT.
5 VERIFY EXISTING FLOOR STRUCTURE BELOW PLUMBING. FLOOR PENETRATION CAN NOT BE THROUGH
CONCRETE BEAMS OR JOISTS.
6 VERIFY PLUMBING CHASE SPACE REQUIREMENTS.
7 NEW SOLID SURFACE WINDOW STOOL AT EXISTING WINDOW. REF. SPECS & CASEWORK DRAWINGS.
1" = 1'-0"2
UL U465 1HR
1" = 1'-0"3
UL U415 1HR & 2HR
FOR USE AT 1 HR INCIDENTAL OCCUPANCY SEPARATION FIRE BARRIERS.
REFER TO SPECIFICATIONS, WHICH MAY HAVE MORE STRINGENT MATERIAL REQUIREMENTS.
FOR USE AT:
1 HR OCCUPANCY SEPARATION FIRE BARRIER (AGAINST EXISTING PARTITION), 2 1/2" MIN. STUDS.
2 HR VERTICAL OPENING FIRE BARRIER, 4" MIN. STUDS.
REFER TO SPECIFICATIONS, WHICH MAY HAVE MORE STRINGENT MATERIAL REQUIREMENTS.
SEE SPECIFICATION SECTION 01 00 00
FOR FIELD VERIFICATION OF EXISTING
CONCRETE COLUMN, BEAM, AND JOIST LOCATIONS.
NOTIFY THE C.O.R. OF ANY CONFLICTS BETWEEN
CONCRETE STRUCTURE (COLUMNS, BEAMS, OR
JOISTS) AND NEW DESIGN ELEMENTS BEFORE
COMMENCEMENT OF NEW CONSTRUCTION OF
EACH PHASE.
No. Description Date
1" = 1'-0"4
TYP. SLAB REPAIR
REF. MEP DRAWINGS FOR EXISTING PENETRATIONS TO BE ABANDONED AND REPAIRED.
PATIENT
ROOM
336-1
EQUIP.
STOR.
338-1
EQUIP.
ALCOVE
300-1
HALL
301-1
HALL
326-1
HALL
339-1
NOT IN
SCOPE OF
WORK
NOT IN
SCOPE OF
WORK
NOT IN
SCOPE OF
WORK
EXIST.
STAIRS
3-STAIR-W
PRIVACY
CURTAIN
(BY VA IN THIS BID ITEM)
ELECT.
328-1
E X
IS
T
D
O O
R T
O R
E M
A
IN
EXIST. DOOR
TO REMAIN
FLOOR PENETRATION IS
EXISTING. EXIST.
CHASE/SHAFT WALLS TO BE
DEMOLISHED AND REBUILT
AFTER NEW MEP WORK IS IN
PLACE.
MODIFIED
OFFICE
312-1-3
MODIFIED
(EXIST.)
PATIENT
RM
311-1-3
EXIST.
TOILET
EXIST.
TOILET
MODIFIED
(EXIST.)
PATIENT
RM
308-1-3
ROOMS TO BE PRESERVED IN THIS BID ITEM:
EXISTING TOILETS (2)
EXISTING PATIENT ROOMS (2) - TO BE MODIFIED TO WORK WITH NEW CORRIDOR.
EXISTING OFFICE - TO BE MODIFIED TO WORK WITH NEW TOILET TO THE NORTH.
SEE SPECIFICATIONS AND NARRATIVE ON SHEET G-105 FOR MORE INFORMATION.
SEE SPECIFICATIONS AND NARRATIVE ON SHEET G-105 FOR
ITEMS TO BE DELETED IN THESE ROOMS AND SPACES FOR
THIS BID ITEM.
SEE SPECIFICATIONS AND NARRATIVE ON SHEET G-105 FOR
ITEMS TO BE DELETED IN THESE ROOMS AND SPACES FOR
THIS BID ITEM.
SEE SPECIFICATIONS AND NARRATIVE ON SHEET G-105 FOR
ITEMS TO BE DELETED IN THESE ROOMS AND SPACES FOR
THIS BID ITEM.
SEE SPECIFICATIONS AND NARRATIVE ON SHEET G-105 FOR
ITEMS TO BE DELETED IN THESE ROOMS AND SPACES FOR
THIS BID ITEM.
CLEAN
UTILITY
330-1
TOILET
335-1
PATIENT
ROOM
334-1
SOILED
UTILITY
319-1
NURSE
STATION
325-1
NOT IN
SCOPE OF
WORK
PATIENT
RM
304-1
BARIATRIC
PATIENT
ROOM
302-1
TOILET
305-1
CHARTING
306-1
HALL
307-1
CLOSET
307A-1
AIRBORNE
INFECTION
ISO.
PATIENT
ROOM
316-1
TOILET
317-1
ANTE RM
318-1
PATIENT
RM
314-1
TOILET
313-1
STORAGE
320-1
TOILET
321-1
PATIENT
RM
322-1
STAFF
TOILET
323-1
HSKPG
324-1
TOILET
337-1
HALL
312-1
EQUIP.
STOR.
329-1
MEDICATION
331-1
330-1 331-1
329-1
337-1
336-1
338-1
323-1
324-1
307-1
304-1
305-1
308-1-3
311-1-3
312-1-3
313-1
314-1
319-1
320-1
322-1318-1316-1
321-1
334-1
EXIST. DOOR
TO REMAIN
NOT IN
SCOPE OF
WORK
E X
IS
T
D
O O
R T
O R
E M
A
IN
BID ITEM 3 - AREAS AFFECTED
E X
IS
T
D
O O
R T
O R
E M
A
IN
TOILET
303-1
Drawing Title Project Title
Date
Location
Checked
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
589A7-17-203
Robert J. Dole VA Medical Center
RENOVATE WARDS FOR PATIENT
PRIVACY PHASE 1, B1
117 PIERCE ST, SUITE 110
SIOUX CITY, IOWA
142 N. MOSELY ST
WICHITA, KANSAS FINAL CONSTRUCTION DOCUMENTS
AS-102.3
3RD FLOOR ARCH. BID ITEM 3
Wichita, Kansas
DCW RMC04-27-2018
1/4" = 1'-0"1
3RD FLOOR - BID ITEM 3 ARCHITECTURAL PLAN
N 2' 4' 8'0'
1/4" = 1'-0"
BID ITEM 3
DOOR SCHEDULE - 3RD FLOOR - BID ITEM 3
DOOR
NO. SIZE
HDWR
SET
DOOR FRAME DETAILS
REMARKSTYPE MAT'L GLASS TYPE MAT'L GLASS HEAD JAMB THRESHOLD
302-1 4' 0" x 7' 0" x 1 3/4" + 2' 0" x 7' 0" x 1 3/4" D 2 1/AS-601 1/AS-601 SIM
303-1 4' 0" x 7' 5 1/2" x 1 3/4" + 2' 0" x 7' 5 1/2" x 1 3/4" LIFT D 4 1/AS-601 1/AS-601 SIM 10/AI-102
304-1 4'-0" x 7'-0" x 1 3/4" A 1 1/AS-601 1/AS-601 SIM
305-1 3'-8" x 7'-5 1/2" x 1 3/4" LIFT A 3 1/AS-601 1/AS-601 SIM 10/AI-102
307-1 3'-0" x 7'-0" x 1 3/4" B 1 1/AS-601 1/AS-601 SIM
308-1-3 4'-0" x 7'-0" x 1 3/4" A 1 1/AS-601 1/AS-601 SIM
311-1-3 4'-0" x 7'-0" x 1 3/4" A 1 1/AS-601 1/AS-601 SIM
312-1-3 3'-0" x 7'-0" x 1 3/4" A 1 1/AS-601 1/AS-601 SIM
313-1 3'-8" x 7'-5 1/2" x 1 3/4" LIFT A 3 1/AS-601 1/AS-601 SIM 10/AI-102
314-1 4'-0" x 7'-0" x 1 3/4" A 1 1/AS-601 1/AS-601 SIM
316-1 3'-8" x 7'-0" x 1 3/4" C 1 1/AS-601 1/AS-601 SIM
317-1 3'-8" x 7'-5 1/2" x 1 3/4" LIFT A 3 1/AS-601 1/AS-601 SIM 10/AI-102
318-1 3'-8" x 7'-0" x 1 3/4" A 1 1/AS-601 1/AS-601 SIM
319-1 3'-4" x 7'-0" x 1 3/4" B 1 1/AS-601 1/AS-601 SIM 45 MIN. RATED
320-1 3'-4" x 7'-0" x 1 3/4" C 1 1/AS-601 1/AS-601 SIM
321-1 3'-8" x 7'-5 1/2" x 1 3/4" LIFT A 3 1/AS-601 1/AS-601 SIM 10/AI-102
322-1 4'-0" x 7'-0" x 1 3/4" A 1 1/AS-601 1/AS-601 SIM 45 MIN. RATED
323-1 3'-0" x 7'-0" x 1 3/4" A 1 1/AS-601 1/AS-601 SIM 9/AI-102
324-1 3'-0" x 7'-0" x 1 3/4" A 1 1/AS-601 1/AS-601 SIM
328-1 3'-0" x 7'-0" x 1 3/4" 10 A WD. - 1 H.M. - 1/AS-601 1/AS-601 SIM
329-1 3'-4" x 7'-0" x 1 3/4" B 1 1/AS-601 1/AS-601 SIM 45 MIN. RATED
330-1 3'-4" x 7'-0" x 1 3/4" B 1 1/AS-601 1/AS-601 SIM 45 MIN. RATED
331-1 3'-4" x 7'-0" x 1 3/4" B 1 1/AS-601 1/AS-601 SIM 45 MIN. RATED
334-1 3'-8" x 7'-0" x 1 3/4" C 1 1/AS-601 1/AS-601 SIM
335-1 3'-8" x 7'-5 1/2" x 1 3/4" LIFT A 3 1/AS-601 1/AS-601 SIM 10/AI-102
336-1 3'-8" x 7'-0" x 1 3/4" 3 C WD. SAFETY, FROSTED
1 H.M. 1/AS-601 1/AS-601 SIM
337-1 3'-8" x 7'-5 1/2" x 1 3/4" LIFT 4 A WD. - 3 H.M. - 1/AS-601 1/AS-601 SIM 10/AI-102
338-1 4'-0" x 7'-0" x 1 3/4" 8 B WD. SAFETY 1 H.M. - 1/AS-601 1/AS-601 SIM 45 MIN. RATED
BID ITEM 3 (DEDUCT #2):
a. PRESERVE TWO EXISTING, MULTIPLE-BED PATIENT ROOMS ON THE THIRD FLOOR AND ELIMINATE THE CONSTRUCTION OF TWO NEW PATIENT ROOMS AND SHOWER ROOMS. THE EXISTING-TO-REMAIN PATIENT ROOMS WILL
REQUIRE MODIFICATION AT THE ENTRANCES TO COMMUNICATE WITH THE NEW CORRIDOR.
CONSTRUCTION OF NEW ROOMS TO BE ELIMINATED IN THIS DEDUCT INCLUDE:
308-1, 309-1, 310-1, AND 311-1.
b. ELIMINATE CASEWORK, TOILETS AND SINKS IN SIX PATIENT ROOM/TOILETS (SEE LISTED BELOW) ON THE THIRD FLOOR AND AT ASSOCIATED LOCATIONS IN THE CORRIDORS. ALL PLUMBING AND ELECTRICAL ROUGH-INS SHALL BE PROVIDED FOR FUTURE INSTALLATION. EXCEPT IN SPACES NOT TO BE REMODELED, ALL NEW CEILINGS REMAIN IN THE PROJECT UNDER THIS BID ITEM.
302-1, 303-1, 304-1, 305-1, 313-1, 314-1, 316-1, 317-1, 318-1, 321-1, 322-1, 334-1, AND 335-1.
c. CASEWORK AND PLUMBING TO BE ELIMINATED (IN ADDITION TO THE PATIENT ROOMS LISTED ABOVE) INCLUDE CASEWORK IN 306-1, 307A-1, AND THE FOLLOWING ITEMS IN THE HALL/CORRIDOR:
EIGHT NURSE SERVERS, LINEN CABINETS, NOURISHMENT STATION, DRINKING FOUNTAIN, AND EYE WASH STATION.
d. SECOND FLOOR ROOMS AND SPACES ARE NOT AFFECTED BY THIS DEDUCT.
e. GENERALLY, DRAWING SHEETS COVERING DETAILS TO BID ITEM 3 END WITH ".3". AN EXAMPLE WOULD BE AS-102.3.
ONLY IN
BID ITEM 3
SEE SPECIFICATION SECTION 01 00 00
FOR FIELD VERIFICATION OF EXISTING
CONCRETE COLUMN, BEAM, AND JOIST LOCATIONS.
NOTIFY THE C.O.R. OF ANY CONFLICTS BETWEEN
CONCRETE STRUCTURE (COLUMNS, BEAMS, OR
JOISTS) AND NEW DESIGN ELEMENTS BEFORE
COMMENCEMENT OF NEW CONSTRUCTION.
BID ITEM FLOOR PLAN KEY NOTES
SEE BID ITEM 1 (BASE BID) FOR ROOM/SPACE DIMENSIONS AND WALL TYPES.1
No. Description Date
PATIENT
ROOM
336-1
EQUIP.
STOR.
338-1
EQUIP.
ALCOVE
300-1
NOT IN
SCOPE OF
WORK
NOT IN
SCOPE OF
WORK
NOT IN
SCOPE OF
WORK
EXIST.
STAIRS
3-STAIR-W
E X
IS
T
D
O O
R T
O R
E M
A
IN
EXIST. DOOR
TO REMAIN
ALL
REV
FLOOR PENETRATION IS
EXISTING. EXIST.
CHASE/SHAFT WALLS TO BE
DEMOLISHED AND REBUILT
AFTER NEW MEP WORK IS IN
PLACE.
EXIST.
PATIENT
RM
EXIST.
PATIENT
RM
EXIST.
PATIENT
RM
EXIST.
TOILET
EXIST.
TOILET
EXIST. RR
EXIST.
PATIENT
RM
EXIST.
NURSE
STATION
RESIDENTS'
OFFICE
EXIST.
MEDS RM.
EXIST.
CLEAN
LINEN
EXIST.
HSKPG
EXIST.
PATIENT
RM
EXIST.
OBSERVATION
EXIST. RR
EXIST.
PATIENT
RM
EXIST.
PATIENT
RM
EXIST.
NURSE
OFFICE
EXIST.
MEN'S RR
EXIST.
STAFF RR
EXIST.
ELEC.
CLOSET
EXIST
MAIN
CORR.
EXIST.
SPD
STORAGE
EXIST.
PATIENT
RM
EXIST.
CLEAN
SUPPLY
EXIST.
PATIENT
RM
EXIST.
TOILET
EXIST.
PATIENT
RM
MODIFIED
EXIST.
STORAGE
EXIST.
TELECOM
TOILET
337-1
THIS SHADED AREA REPRESENTS THE APPROXIMATE
AREA TO BE PRESERVED IN THIS BID ITEM.
SEE SPECIFICATIONS AND NARRATIVE ON
SHEET G-105 FOR MORE INFORMATION.
GENERALLY THESE SPACES ARE EXISTING TO REMAIN.
NOT IN
SCOPE OF
WORK
336-1
337-1
338-1
E X
IS
T
D
O O
R T
O R
E M
A
IN
E X
IS
T
D
O O
R T
O R
E M
A
IN
E X
IS
T
D
O O
R T
O R
E M
A
IN
E X
IS
T
D
O O
R T
O R
E M
A
IN
EXIST. DOOR
TO REMAIN
EXIST. DOOR
TO REMAIN
EXIST. DOOR
TO REMAIN
EXIST. DOOR
TO REMAIN
EXIST. DOOR
TO REMAIN
EXIST. DOOR
TO REMAIN
EXIST. DOOR
TO REMAIN
EXIST. DOOR
TO REMAIN
E X
IS
T
D
O O
R T
O R
E M
A
IN
E X
IS
T
D
O O
R T
O R
E M
A
IN
EXIST. DOOR
TO REMAIN
EXIST. DOOR
TO REMAIN
EXIST. DOOR
TO REMAIN
EXIST. DOOR
TO REMAIN
EXIST. DOOR
TO REMAIN
E X
IS
T
D
O O
R T
O R
E M
A
IN
EXIST. DOOR
TO REMAIN
EXIST. DOOR
TO REMAIN
EXIST. DOOR
TO REMAIN
EXIST. DOOR
TO REMAIN
E X
IS
T
D
O O
R T
O R
E M
A
IN
E X
IS
T
D
O O
R T
O R
E M
A
IN
E X
IS
T
D
O O
R T
O R
E M
A
IN
E X
IS
T
D
O O
R T
O R
E M
A
IN
EXIST. DOOR
TO REMAIN
E X
IS
T
D
O O
R T
O R
E M
A
IN
THIS SHADED AREA REPRESENTS THE APPROXIMATE
AREA TO BE PRESERVED IN THIS BID ITEM.
SEE SPECIFICATIONS AND NARRATIVE ON
SHEET G-105 FOR MORE INFORMATION.
GENERALLY THESE SPACES ARE EXISTING TO REMAIN.
E X
IS
T
D
O O
R T
O R
E M
A
IN
BID ITEM 4 - AREAS AFFECTED
PRIVACY
CURTAIN
(BY VA IN THIS BID ITEM)
Drawing…