537-19-124 - SOW Ex - Campus Floor Plan 2 of 2.pdf

PDF 10 MB Posted

Attached to
Z1DA--537-19-124 Upgrade Nurse Call
Solicitation number
36C25222B0012
Issued by

About this file

This document provides details for a federal contract solicitation to upgrade the nurse call system at the Jesse Brown VA Medical Center in Chicago, Illinois. The solicitation was issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 12 seeking bids to replace the nurse call system under project number 537-19-124. Contractors are invited to provide a lump sum base bid to furnish all labor, materials, equipment, supervision and other items designated in the contract documents to complete the nurse call replacement project within 428 calendar days of receiving a notice to proceed. The price range for the project is estimated between $2,000,000 to $5,000,000. Bids are due by the date specified in solicitation number 36C25222B0012.

View the file

Other files

File Type Posted
36C25222B0012 0007.docx DOCX document
36C25222B0012 0006.docx DOCX document
36C25222B0012 0005.docx DOCX document
Pre-Bid RFI 537-19-124_AE and VA.xlsx XLSX spreadsheet
36C25222B0012 0004.docx DOCX document
P01 - Specifications.pdf PDF
36C25222B0012 0003.docx DOCX document
36C25222B0012 0002.docx DOCX document
02c1 - 537-19-124 SOW Att - Contract Progress Report.pdf PDF
02b2 - 537-19-124 SOW Ex - Asbestos Survey Report.pdf PDF
537-19-124 - SOW Ex - Campus Floor Plan 1 of 2.pdf PDF
02a1 - 537-19-124 SOW CD - Construction Plans.pdf PDF
S02 - Asbestos Survey Report.pdf PDF
S02 - Nurse Call and Code Blue Systems.pdf PDF
S02 - Statement of Conditions-Campus Floor Plan.pdf PDF
S02 - Drawings.pdf PDF
36C25222B0012 0001.docx DOCX document
S02 - Contractor Production Report.pdf PDF
S02 - Wage Determination_DB_IL20210009.pdf PDF
S02 - Contract Progress Report.pdf PDF
S02 - Specifications.pdf PDF
S02 - Subcontractor Payment Summary.xlsx XLSX spreadsheet
36C25222B0012_1.docx DOCX document
Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STORAGE

ELEC.

23E4

STORAGE

2297B

ELEC.

23E1

MECH RM

2600A

MENS

TOILET

RECEPTION

CORRIDOR

C2207

CORRIDOR

C2301

LOUNG

KITCH

NORTH PENT HOUSE

BUILDING 30

A D

PHYSICIANS

OFFICE

TOILET

EXAM RM-9

EXAM RM-8

CORRIDOR

C2305

PURPLE CLINIC

WAITING RM

CORRIDOR

C2306

LOUNGE

SUPPLY

SOILED

LINEN

OFFICE

EXAM RM-2

WOMENS

TOILET

CORRIDOR

C2304

CORRIDOR

C2303

HAC

NURSE

OFFICE

RADIOLOGY

CORE/

COMPUTER RM

ELECTRICAL

23E2

STAIR

NO 7

HAC

EXAM RM-1

WAITING

RECEPTION

TREATMENT

RM

NURSES

OFFICE

EXAM RM-7

EXAM RM-6

TOILET

EXAM RM-5

EXAM RM-4

EXAM RM-3

DOCTOR OFFICE

PACT NURSE

EXAM RM-1

EXAM RM-2

EXAM RM-3

NURSE

OFFICE

PROGRAM

MGNT

DOCTOR OFFICE

STAIR

NO 6

EXAM RM-4

EXAM RM-5

EXAM RM-6

EXAM RM-7

SUPPLY RM

PTSD DAY RM

STAIR

NO 8

STORAGE

GROUP RM

GROUP

RM

CHIEF

DAY PGM

CORRIDOR

C2302

COPY

RM

WOMENS

TOILET

ELEV.

P-8 B

ELEV.

P-9 B

ELEV.

S-10 B

FUTURE

ELEV.

ELEV.

P-7 B

BREAK RM

SUPPLIES

BUILDING 30 SOUTH

PENTHOUSE

SEXUAL HEALTH

STORAGE/

HAC

PRIMARY

CARE

NURSE

LCSW

OFFICE

LCSW

OFFICE

LCSW

OFFICE

STAIR

NO 9

QUIET RM

EXAM RM

CO-ORDR

TRAINEE RM

STAFF

PSYCHOLOGIST

CLINICAL

PSYCHOLOGIST

LCSW

OFFICE

LCSW

OFFICE

VESTIBULE

C2208

TELECOM

22T2

EXAM RM

EXAM RM

EXAM RM

2295STORAGE

TOILET

EXAM RM

EXAM RM

EXAM RM

2292A

PROCEDURE

RM

MEDICAL TEAM

EXAM RM

EXAM RM

EXAM RM

TRIAGE

MED RM

CORRIDOR

C2206

SPECIALTY CLINICS

WAITING

WAITING

RECEPTION

ELECTRICAL

22E5

ELECTRICAL

22E4

NURSE MGR

HAC

STORAGE

EXAM RM

CORRIDOR

C2202

CORRIDOR

C2205STORAGE

CRASH

CART

2273A

EXAM RM

NURSE

TRIAGE

EXAM RM

EXAM RM

EXAM RM

CORRIDOR

C2203

EXAM RM

EXAM RM

EXAM RM

EXAM RM

MEDICAL TEAM

EXAM RM

EXAM RM

EXAM RM

ELEVATOR

S3-A

FEMALE

TOILET

STORAGE

STORAGE

MALE

TOILET

STORAGE

HAC

WAITING

WAITING

CORRIDOR

C2201

DDTC

ELECTRICAL

22E1

CONFERENCE RM

STORAGE

STORAGE

THERAPY GROUP

DDTC

TECH

DDTC

RESIDENT

TOILET

WOMENS

TOILET

MALE

TOILET

ATP SUPV

OFFICE

STAIR

NO 12

THERAPY

GROUP

PSYD DDTC

CO-ORDR

DDTC

DDTC

NURSE

OFFICE

ADDICTION

THERAPIST

OFFICE

PGM

SUPPORT

OFFICE

KITCHEN

ELECTRICAL

22E2

IRM

22T1

ELEV.

P1-A

RECREATION

RM - A

STAIR

NO 11

VOC

REHAB

AT

OFFICE

AT

OFFICE

AT

OFFICE

MEDICAL

SUPPORT

OFFICE

STAIR

NO 10

SOCIAL

WORKER

DDTC

DIRECTOR

2225A

P-6B

2384A

2344A

C2307

AT

OFFICE

RECEPTION DDTC

DRUG

DISPENSING

FIRE

CLOSET

VESTIBULE

CLOSET

FIRE

CLOSET

CLOSET

CORRIDOR

SPD

SUPPLY

2230A

RECREATION

RM - B

AT

OFFICE

HOMELESS

OFFICE

RECREATION

THERAPIST

EMERGENCY

GENERATOR

RM/MEZZANINE

1300B

RESEARCH

OFFICE

OXYGEN

TANK

2253A

HOME

CARE 2

SLEEP

DOCTOR

LEAD TECH

ATTENDING

DOCTORS

2247B

SUPPORT

ASSIST

2247A

CONFERENCE

CHIEF OF

PULMONARY

CARE

22472246

DIRECTOR

OF SLEEP

CORRIDOR

C2206

CORRIDOR

C2204

TOILET

HOME CARE 3

HALL

2254B

ACCESS

TOILET

2258A

ELECTRICAL

CLOSET

2243B

COMPRESSED

TANK

2240A

PFT LAB - 1

PFT

LAB - 2

PFT

LAB - 3

HALL

2254D

WAITING

2254ACCESS

TOILET

2254A

NURSE

HOME CARE 1

HALL

2254C

CANOPY

VESTIBULE

CONCRETE

GLASS

CANOPY

OPEN TO BELOW

OPEN TO BELOW

( BLDG 30 SKYLIGHT )

SURGY CLINIC

PHARMACY

MEDICATION

WOMENS HEALTH

CLINIC

OPEN TO BELOW

BUILDING 30

ROOF

PLATE

COVER

LOUVER

LOUVER

TO ACCESS

LOUVERLOUVER LOUVER

ROOF

ROOF

ROOF

DN

FEC

FEC

FEC

2225A

ELEC.

23E3

ELEC.

ELEV.

P2-A

ELEV.

P4-A

ELEV.

P5-A

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SYMBOLS LIST

HORIZONTAL EXIT PASSAGEWAY

EXIT

EXIT PASSAGEWAY

LINEN CHUTE

TRASH CHUTE

FP&C Project Number

CONSULTANTS, LLC.

1520 MAIN STREET

INDIANAPOLIS, IN 46224

(317) 486-5188

FIRE PROTECTION & CODE

1741.33

AREA OPEN TO CORRIDOR WITH SMOKE DETECTION

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

SUITE DESIGNATION

1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

UPDATE STATEMENT OF

CONDITIONS

JESSE BROWN VAMC

SPRINKLER / FIRE SMOKE ZONE

SITE PLAN

OGDEN AVENUE

PO

LK

S

TR

EE

T

DAMEN AVENUE

TA

YL

O R

S

TR

EE

T

11B

1B

1A

11A

DEVICE LIST

FIRE EXTINGUISHER

EXIT SIGN

EMERGENCY LIGHT

FIRE ALARM PULL STATION

FIRE ALARM CONTROL PANEL

FIRE ALARM ANNUNCIATOR PANEL

AUTOMATED EXTERNAL DEFIBRILLATOR

EYEWASH STATION

SPRINKLER SYSTEM RISER

POSITIVE PRESSURE ROOM 15%

NEGATIVE PRESSURE ROOM 15%

POSITIVE PRESSURE ROOM 30%

NEGATIVE PRESSURE ROOM 30%

PARTIAL SECOND FLOOR PLAN

BUILDING 11 & 30

STATEMENT OF CONDITIONS

NON-RATED SMOKE PARTITION

1C

33% DRAFT B40 SOC

4/13/2020

66% DRAFT B1 SOC 5/8/2020

99% DRAFT B11-30 SOC 7/10/2020

FINAL 8/7/2020

NON SPRINKLERED ELECTRICAL ROOM PER SECTION

8.15.10.3 OF NFPA 13 2013 EDITION.

EXIT PASSAGEWAY PER SECTION 7.2.6 OF NFPA 101-2012

EDITION. UTILITIES INSTALLED ABOVE SUSPENDED

CEILING PRIOR TO THE CURRENT REQUIREMENTS NOW

FOUND IN SECTION 7.1.3.2.1(10) OF NFPA 101-2012 EDITION

AND FIRST ADOPTED IN THE 1985 EDITION.

ELECTRICAL UTILITY INSTALLED IN STAIRWAY PRIOR TO

THE CURRENT REQUIREMENTS NOW FOUND IN SECTION

7.1.3.2.1(10) OF NFPA 101-2012 EDITION AND FIRST

ADOPTED IN THE 1985 EDITION.

NOT AN EXIT. CIRCULATION STAIR ONLY.

FIRE RATED GLASS WALL-60 MINUTE RATED.

LOCKED FOR CLINICAL NEEDS OF THE PATIENTS PER

SECTION 19.2.2.2.5.1 OF NFPA 101-2012.

SINGLE EXIT ROOM. MAXIMUM 49 OCCUPANTS.

CONTINUOUS HINGE COVERING DOOR RATING PLATE.

FIRE ESCAPE LADDER PER SECTION 7.2.9 OF NFPA

101-2012 EDITION.

FIRE SPRINKLERS INSTALLED PER LIBRARY AND SHELVING

STORAGE SPACING REQUIREMENTS OF SECTION 8.5.10 OF

NFPA 13-2013 EDITION.

POWER OPERATED DOORS RELEASE UPON FIRE ALARM

SIGNAL.

ALTERNATING TREAD STAIR PER SECTION 7.2.11 OF NFPA

101-2012 EDITION.

FOAM ACOUSTICAL PANELS INSTALLED ON THE CEILINGS

HAVE A CLASS A SMOKE SPREAD AND SMOKE DENSITY

RATING ( SEE TECHNICAL DATA SHEET IN SOC BINDER)

PER THE ASTM E84 FIRE MATERIALS TEST AND AS

PERMITTED BY SECTION 18/19.3.3.2 OF NFPA 011-2015

EDITION.

NON SPRINKLERED PIPE SPACE PER SECTION 8.1.1 OF

NFPA 13.2013 EDITION

SPRINKLERS INSTALLED ABOVE AUDIO BOOTHS PER 1985

DIRECTIVE

EXISTING 3/16" MINIMUM STEEL PLATE FLOOR ACCESS

PANEL CONSIDERED EQUIVALENT TO 2 HOUR FLOOR

ASSEMBLY AT THE TIME OF BUILDING CONSTRUCTION.

NON-LABELED STEEL DOOR FRAMES WERE INSTALLED

PRIOR TO THE CURRENT LABELED DOOR FRAME

REQUIREMENTS FOUND IN SECTION 4.2.14.4 OF NFPA 80

AND FIRST APPLIED IN THE 1959 EDITION

GENERAL KEY NOTES:

SEE EQUIVALENCY FOR INSTALLATION OF

WIRELESS ACCESS POINT EQUIPMENT

WITHIN EXIT STAIR ENCLOSURES.

OVERSIZED PROTECTIVE PLATES ON FIRE

RATED DOORS.

SEE EQUIVALENCY FOR DEAD END

CORRIDORS WITHIN A BUSINESS

OCCUPANCY.

EQUIVALENCY KEY NOTES:

PARTIAL SECOND FLOOR PLAN

FULLY SPRINKLERED; QUICK RESPONSE TYPE

BUSINESS OCCUPANCY

11 & 30

537-20-102

UP

ROOF

METAL DOOR

ROOF

ROOF

SKYLIGHT ROOF

ROOF

ROOF

ROOF

ROOF

ROOF

ROOF

ROOF

CONCRETE PAD

LADDER

CPRS

OFFICE

TELECOM

32T1

ELEC.

32E2

ELEV.

P-1A

ELEV.

P-2A

ELEVATOR

S-3A

ELEV.

ELEV.

P-5A

ELECTRICAL

32E4

LOCKSMITH

ELECTRICAL

32E5

WOMENS

TOILET

STORAGE

ELEV.

S-10

ELEV.

P-9

ELEV.

P-8

ELEV.

P-6

ELEV.

P-7

ELECTRICAL

33E3

ELECTRICAL

33E2

PHONE

3299A

ELECTRICAL

32E3

ELECTRICAL

33E1

PROSTHETICS WAITING

AREA

OFFICE

CUBICLE

CORRIDOR

C3302

WOMENS

TOILET

STAIR

NO 8

CORRIDOR

C3301

LAB

3375A

LAB

STAIR

NO 6

WOMENS LOCKER

3325B

HAC

FITTING RM

STAIR

NO 7

MENS TOILET

HOME

OXYGEN

PROG

PROSTHETIC

ORTHOTIC LAB

TOILET

OFFICE

STAFF OFFICE

PROSTHETIC

OFFICE

PROSTHETIC

REPRESENTATIVE

OFFICE

PROGRAM

SUPPORT

PGM MGR

VESTIBULE

C3201

PROSTHETIC STORAGE

33073303

SHOWER

CORRIDOR

C3203

CORRIDOR

C3206

CORRIDOR

C3205

CORRIDOR

C3204

CORRIDOR

C3202

OFFICE STAFF

ENGG SVC

DRAFTING AREA

CONFERENCE RM

ADMIN OFFICE

ENGG CHIEF

TRANSIT CO-ORDR

ASST CHIEF

ENGINEER

OFFICE STAFF

ENERGY MGR

OFFICE STAFF

OFFICE STAFF

32783277327632753274

MENS LOCKER

MENS TOILET

TELECOM

32T2 STAIR

NO 9

INTERIOR DESIGN

OFFICE

SECY

ADMIN OFFICER

INTERIOR DESIGNER

LIBRARY SVC

EMS CHIEF

STORAGE

OFFICE

SUPPLY

MALE TOILET

FEMALE

TOILET

CONFERENCE RM

CONFERENCE RM

STAIR

NO 12

32E1

WORK AREA

WORK AREA

ANALYST

OFFICE

PATIENT HEALTH

RESOURCE

CENTER

PHARMACY DRUG

STORAGE

PHARMACY DRUG

STORAGE

CREDENTIALING

PGM

CREDENTIALING

PGM

EMS HAC

SUPERVISOR P&P

IH OFFICE

EMERGENCY MGMT

OFFICE

HAC

STAIR

NO 11

NURSE CONFERENCE RM

NURSE

EDUCATION

STAIR

NO 10

CLASS RM

COMPUTER

NURSE

OFFICE

NURSE

OFFICE

NURSE

OFFICE

CPRS OFFICE

CPRS OFFICE

OFFICE

FEC

FEC

P-4A

ELECTRICAL CLOSET

FEC

FEC

OFFICE

CUBICLE

OFFICE

CUBICLE

OFFICE

CUBICLE

OFFICE

CUBICLE

OFFICE

CUBICLE

OFFICE CUBICLE

COPIER RMKITCHENFILE STORAGE

3280A

MENS LOCKER

FEC

FEC

PLASTER

AREA

FEC

VESTIBULE

EMPLOYEE

LOUNGE

3325A

ANALYST

OFFICE

3210A

TRAINING RM

3210B

CHIEF OFFICE

3210C

OFFICE

3210D

CORRIDOR

C3303

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SYMBOLS LIST

HORIZONTAL EXIT PASSAGEWAY

EXIT

EXIT PASSAGEWAY

INDIANAPOLIS, IN 46224

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

SUITE DESIGNATION

PO

LK

S

TR

EE

T

DAMEN AVENUE

TA

YL

O R

S

TR

EE

T

11B

1B

1A

EXIT SIGN

EMERGENCY LIGHT

FIRE ALARM PULL STATION

FIRE ALARM CONTROL PANEL

POSITIVE PRESSURE ROOM 15%

NEGATIVE PRESSURE ROOM 15%

POSITIVE PRESSURE ROOM 30%

NEGATIVE PRESSURE ROOM 30%

PARTIAL THIRD FLOOR PLAN

8.15.10.3 OF NFPA 13 2013 EDITION.

EXIT PASSAGEWAY PER SECTION 7.2.6 OF NFPA 101-2012

EDITION. UTILITIES INSTALLED ABOVE SUSPENDED

CEILING PRIOR TO THE CURRENT REQUIREMENTS NOW

FOUND IN SECTION 7.1.3.2.1(10) OF NFPA 101-2012 EDITION

AND FIRST ADOPTED IN THE 1985 EDITION.

ELECTRICAL UTILITY INSTALLED IN STAIRWAY PRIOR TO

THE CURRENT REQUIREMENTS NOW FOUND IN SECTION

7.1.3.2.1(10) OF NFPA 101-2012 EDITION AND FIRST

ADOPTED IN THE 1985 EDITION.

NOT AN EXIT. CIRCULATION STAIR ONLY.

FIRE RATED GLASS WALL-60 MINUTE RATED.

LOCKED FOR CLINICAL NEEDS OF THE PATIENTS PER

SECTION 19.2.2.2.5.1 OF NFPA 101-2012.

SINGLE EXIT ROOM. MAXIMUM 49 OCCUPANTS.

CONTINUOUS HINGE COVERING DOOR RATING PLATE.

FIRE ESCAPE LADDER PER SECTION 7.2.9 OF NFPA

101-2012 EDITION.

FIRE SPRINKLERS INSTALLED PER LIBRARY AND SHELVING

STORAGE SPACING REQUIREMENTS OF SECTION 8.5.10 OF

NFPA 13-2013 EDITION.

POWER OPERATED DOORS RELEASE UPON FIRE ALARM

SIGNAL.

ALTERNATING TREAD STAIR PER SECTION 7.2.11 OF NFPA

101-2012 EDITION.

FOAM ACOUSTICAL PANELS INSTALLED ON THE CEILINGS

HAVE A CLASS A SMOKE SPREAD AND SMOKE DENSITY

RATING ( SEE TECHNICAL DATA SHEET IN SOC BINDER)

PER THE ASTM E84 FIRE MATERIALS TEST AND AS

PERMITTED BY SECTION 18/19.3.3.2 OF NFPA 011-2015

EDITION.

NON SPRINKLERED PIPE SPACE PER SECTION 8.1.1 OF

NFPA 13.2013 EDITION

SPRINKLERS INSTALLED ABOVE AUDIO BOOTHS PER 1985

DIRECTIVE

EXISTING 3/16" MINIMUM STEEL PLATE FLOOR ACCESS

PANEL CONSIDERED EQUIVALENT TO 2 HOUR FLOOR

ASSEMBLY AT THE TIME OF BUILDING CONSTRUCTION.

NON-LABELED STEEL DOOR FRAMES WERE INSTALLED

PRIOR TO THE CURRENT LABELED DOOR FRAME

PARTIAL THIRD FLOOR PLAN

FULLY SPRINKLERED; QUICK RESPONSE TYPE

BUSINESS OCCUPANCY

SKYLIGHT ROOF

ROOF

ROOF

ROOF

ROOF

ROOF

ROOF

ROOF

PRRC

SOCIAL

WORK

4293A

ELEC.

42E2

ELECTRICAL

42E3

VESTIBULE

STORAGE

NURSE INTAKE

PRRC

COORDINATOR

PRRC

NURSE

CWT

OFFICE

CWT

OFFICE

UR NURSE

ELECTRICAL

42E1

TELECOM

42T2

IRM

CLOSET

4298A

CWT

OFFICE

RECREATION

THERAPIST

OFFICE

FIRE

CLOSET

FAC

FIRE

CLOSET

4200A

PHONE

ELECTRICAL

43E2

ELECTRICAL

43E3

ELECTRICAL

43E1

FIRE

CLOSET

CORRIDOR

C4302

SOCIAL WORK

CUBICLE

4210B

SOCIAL WORK

CUBICLE

4210C

SOCIAL WORK

4210A

RECEPTION/

WAITING

VOLUNTARY SVC

CORRIDOR

C4303

AUDIO / ENT SUITE

CORRIDOR

C4205

CORRIDOR

C4304

PROG

ASSIST

4205B

CORRIDOR

C4206

CORRIDOR

C4203

CORRIDOR

C4204

CORRIDOR

C4201

CORRIDOR

C4202

DAY TREATMENT RM

RECEPTION

MENS TOILET

NURSE

INTAKE

CORRIDOR

C4301

BREAK

AREA

RECEPTION

NURSE

INTAKE

NURSE

INTAKE

WAITING AREA

MECH RM

STAIR

NO 6 MECH RM

STORAGE

STORAGE

ENT CLERK

STORAGE

HAC

4374MENS TOILET

WOMENS TOILET

ELEV.

S-10B

ELEV.

P-9B

ELEV.

P-8B

WAITING RM

WAITING

FILE

STORAGE

AREA

CHIEF OFFICE

STORAGE

4328SPEECH

PATH

ELECTRO

EXAM RM

4332SPEECH

PATH

AUDIOLOGIST

SPEECH

PATH

AUDIO

OFFICE

WORK SHOP

AUDIO

OFFICE

SOUND

CONTROL

4343A

SOUND

BOOTH

STAIR

NO 8

SOUND

CONTROL

4339A

BOOTH

SOUND

SOUND

BOOTH

SOUND

CONTROL

4341A

SOUND

CONTROL

4333A

COMMON RM

SOUND

BOOTH

HAC

STAIR

NO 7

ELEV.

P-7B

STORAGE/OFFICE

LOGISTICS

PERSONAL

PROPERTY MGMT

OFFICE

SOCIAL WORKER

4205E

VESTIBULE

PRRC

OFFICE

RN OFFICE

4284A

ISO OFFICE

4286A CWT OFFICE

STORAGE

KITCHEN

PRRC

SOCIAL WORK

PRRC

CLASS RM

VOC

REHAB

4289IRM WORK AREA

OPEN

STORAGE

STORAGE

RECEPTION

FILE

STORAGE

AREA

4270A

SECRETARY

AREA

4263A

OPEN

OFFICE

STAFFING

CHIEF

LABOR

RELATION

CHIEF

A/O

OFFICE

MALE TOILET

STORAGE/

OFFICE

HAC

CONFERENCE RM

SOCIAL WORK

OFFICE

SOCIAL

WORK

SOCIAL

WORK

SUPV

OFFICE

SOCIAL

WORK

A.O. OFFICE

CHIEF OFFICE

STAIR

NO 12

OFFICE

4205C

CHIEF

OFFICE

SUPV OFFICE

4205D

LOGISTICS MGR OFFICE

4207B

OFFICE

4207A

LOGISTICS

PERSONAL

PROPERTY MGNT

NURSING

STAFF

OFFICE

LOCKER

4245E

STORAGE

4245FCHIEF

4245G

ASST CHIEF

OFFICE

4245D

VOLUNTARY

STAFF

4245C

VOLUNTARY

OFFICE

4245C

OFFICE

4245B

RECEPTION

AREA

4245B1

IRM

CLOSET

42T1

CLERK OFFICE

EDUCATION

STAFF

STRIKE

FORCE

EDUCATION STAFF

OFFICE

STAIR

NO 10

OFFICE

OFFICE

OFFICE

4349OFFICE

EXAM RM

EXAM RM

EXAM RM

4306DIRTY

UTILITY

CLEAN SUPPLY

STAIR

NO 9

COMPUTER LAB

4295A

CWT OFFICE

RECREATION

THERAPIST

OFFICE

PURCHASE

CARE

CO-ORDR

4276A

FEMALE

TOILET

ELEV.

P-5A

ELEV.

P-4A

ELEVATOR

S-3A

ELEV.

P-1A

ELEV.

P-2A

STAIR

NO 11

NURSE

INTAKE

STORAGE

STORAGE

4279A

ELECTRIC

CLOSET

42E4

STORAGE

STORAGE

4245A

CHIEF OFFICE

BUDGET OFFICE

OFFICE

WOMENS

TOILET

OFFICE

CONFERENCE

RM

CWT

OFFICE

4289A

LOCKER/

REFRIG

4289C

WAITING

RM

4289B

CORRIDOR

C4201A

PROG

ASSIST

4205A

CWT GROUP RM

4280A

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SYMBOLS LIST

HORIZONTAL EXIT PASSAGEWAY

EXIT

EXIT PASSAGEWAY

INDIANAPOLIS, IN 46224

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

SUITE DESIGNATION

PO

LK

S

TR

EE

T

DAMEN AVENUE

TA

YL

O R

S

TR

EE

T

11B

1B

1A

EXIT SIGN

EMERGENCY LIGHT

FIRE ALARM PULL STATION

FIRE ALARM CONTROL PANEL

POSITIVE PRESSURE ROOM 15%

NEGATIVE PRESSURE ROOM 15%

POSITIVE PRESSURE ROOM 30%

NEGATIVE PRESSURE ROOM 30%

PARTIAL FOURTH FLOOR PLAN

8.15.10.3 OF NFPA 13 2013 EDITION.

EXIT PASSAGEWAY PER SECTION 7.2.6 OF NFPA 101-2012

EDITION. UTILITIES INSTALLED ABOVE SUSPENDED

CEILING PRIOR TO THE CURRENT REQUIREMENTS NOW

FOUND IN SECTION 7.1.3.2.1(10) OF NFPA 101-2012 EDITION

AND FIRST ADOPTED IN THE 1985 EDITION.

ELECTRICAL UTILITY INSTALLED IN STAIRWAY PRIOR TO

THE CURRENT REQUIREMENTS NOW FOUND IN SECTION

7.1.3.2.1(10) OF NFPA 101-2012 EDITION AND FIRST

ADOPTED IN THE 1985 EDITION.

NOT AN EXIT. CIRCULATION STAIR ONLY.

FIRE RATED GLASS WALL-60 MINUTE RATED.

LOCKED FOR CLINICAL NEEDS OF THE PATIENTS PER

SECTION 19.2.2.2.5.1 OF NFPA 101-2012.

SINGLE EXIT ROOM. MAXIMUM 49 OCCUPANTS.

CONTINUOUS HINGE COVERING DOOR RATING PLATE.

FIRE ESCAPE LADDER PER SECTION 7.2.9 OF NFPA

101-2012 EDITION.

FIRE SPRINKLERS INSTALLED PER LIBRARY AND SHELVING

STORAGE SPACING REQUIREMENTS OF SECTION 8.5.10 OF

NFPA 13-2013 EDITION.

POWER OPERATED DOORS RELEASE UPON FIRE ALARM

SIGNAL.

ALTERNATING TREAD STAIR PER SECTION 7.2.11 OF NFPA

101-2012 EDITION.

FOAM ACOUSTICAL PANELS INSTALLED ON THE CEILINGS

HAVE A CLASS A SMOKE SPREAD AND SMOKE DENSITY

RATING ( SEE TECHNICAL DATA SHEET IN SOC BINDER)

PER THE ASTM E84 FIRE MATERIALS TEST AND AS

PERMITTED BY SECTION 18/19.3.3.2 OF NFPA 011-2015

EDITION.

NON SPRINKLERED PIPE SPACE PER SECTION 8.1.1 OF

NFPA 13.2013 EDITION

SPRINKLERS INSTALLED ABOVE AUDIO BOOTHS PER 1985

DIRECTIVE

EXISTING 3/16" MINIMUM STEEL PLATE FLOOR ACCESS

PANEL CONSIDERED EQUIVALENT TO 2 HOUR FLOOR

ASSEMBLY AT THE TIME OF BUILDING CONSTRUCTION.

NON-LABELED STEEL DOOR FRAMES WERE INSTALLED

PRIOR TO THE CURRENT LABELED DOOR FRAME

PARTIAL FOURTH FLOOR PLAN

BUILDING 11 & 30

FULLY SPRINKLERED; QUICK RESPONSE TYPE

BUSINESS OCCUPANCY

11 & 30

FAC

FAC

ROOF

ROOF

SKYLIGHT ROOF

ROOF

ROO

ROOF

ROOF

ROOF

ROOF

ROOF

UPUPUP

CHIEF

OPHTHALMOLOGY

ELEC.

CLOSET

52E3

ELEC.

CLOSET

52E5

WORK RM

5380A

ELEV.

P-2A

ELECTRICAL

53E1

ADMN.

OFFICER

FAC

ELECTRICAL

53E2

FIRE

CLOSET

TEL

52T1

ELECTRICAL

52E2

PRINTER/FAX

AREA

PGM

SPECIALIST

CORRIDOR

C5303

STORAGE

OFFICE

ELECTRICAL

CLOSET

52E4

OFFICE

FEMALE

TOILET

CONFERENCE RM

STORAGE

TISSUE

CULTURE

5278A

RESEARCH

LAB-5

VOLUNTARY

STORAGE

VOLUNTARY

STORAGE

5284A

OFFICE

OFFICE

VOLUNTARY

STORAGE

CORRIDOR

C5202

CORRIDOR

C5201

TEL

STAIR

NO 9

MECH RM

MECH RM

5292A

OFFICE

OFFICE

5289 AUTOCLAVE

GLASS

WASH

RESEARCH

LAB-4

TISSUE

CULTURE

LAB

LAB

OFFICE

5279COLD

LAB

TISSUE

CULTURE

5275ARESEARCH

LAB-1

OFFICE AREA

OFFICE AREA

5230 CPAC

C5204

PREVENTION

CO-ORDR

PGM

SPECIALIST

PATIENT

SAFETY

ELEC.

CLOSET

52E1CONFERENCE RM

CPAC

RECEPTION

ADMIN ASST

TIME KEEPER

TIME KEEPER

CLAIM ASST

PASSAGE

5201A

SECY AND

CLERK

INPT

ASSOC

OUT

PATIENT

ASSOC

CONFERENCE RM

5208 NURSING

CHIEF

5207 STAIR

NO 12

NURSE

OFFICE

LEAD CLAIM

ASST

MAGNET

CO-ORDR

ADPAC

TIME

KEEPER

MALE

TOILET

SUPPLY

HAC

CORRIDOR

C5203

STORAGE

ELEVATOR

S-3A

NURSING

TRAINING

SUPV-RECORD

PROCESSING

SUPV

CPAC

OFFICE

INFECTION

CONTROL

CORRIDOR

C5205

STAIR

NO 11

CORRIDOR

C5206

REPRODUCTION

5260A

SWING SPACE

5260B

FISCAL

OFFICE

FEE BASIS

FEE

BASIS

WAITING

AREA

PASSAGE

CORRIDOR

C5207

STAIR

NO 10

HEALTH

SCIENCE

SPECIALIST

PGM

SPECIALIST

PI SPECIALIST

PI

SPECIALIST

PATIENT

SAFETY

MGR

PI CHIEF

FISCAL OFFICE

RELEASE OF

INFO

RELEASE OF

INFO

RELEASE OF INFO

RELEASE OF INFO

MEDICAL

RECORDS

RELEASE OF

INFO

RELEASE OF

INFO

FISCAL

OFFICE

FISCAL

OFFICE

WAITING AREA

TEL

WOMENS

TOILET

IMAGING

EXAM RM

5374B

NURSE

INTAKE-15

CORRIDOR

C5302

STAIR

NO 7

RME STORAGE

5332B

BIO-FEEDBACK

LAB

OPHTH

IMAGING

IMAGING

EXAM RM

5374A

EYE EXAM RM - 7

EYE EXAM RM - 8

EYE EXAM RM - 9

EYE EXAM RM - 10

TOILET

MEDICINE

PREP

MINOR

SURGY

STAIR

NO 6

CORRIDOR

C5301

PHOTO

RM

OPHTH

OFFICE

VISION

FIELD

EYE EXAM RM - 5

EYE EXAM -4

VISION

FIELD

EYE EXAM RM - 2

EYE EXAM

RM - 1

5361BIO

HAZARD

CLOSET

CONSULTATION

OFFICE

CONSULT

OFFICE

CONSULT

OFFICE

CHIEF

BREAK

RECEPTION

ADMIN

OFFICE

EYE

EXAM RM

53O6

EYE

EXAM RM

EYE

EXAM RM

WAITING RM

NURSE

INTAKE

LOW

VISION

EYE

EXAM

EYE

EXAM

MENS

TOILET

ELEV.

P-6B

STAFF

TOILET

HAC

EYE

LASER

EYE

LASER

VISUAL

FIELD

PSYCHOLOGY

OFFICE

PSYCHOLOGY

OFFICE

PSYCHOLOGY

OFFICE

STAIR

NO 8

CHIEF

COPIER/

STORAGE

5324A

CONFERENCE RM

STORAGE

5332A

ADMIN.

OPHTHALMOLOGY

BIO-FEEDBACK

PSYCHOLOGY

STAFF OFFICE

BIO-FEEDBACK

COPIER

AREA

C5207

OFFICE

AREA

5230A

CPAC OFFICE

AREA

5232B

CPAC WAITING

AREA

5232A

NURSE OFFICE

NURSING

COPIER

5204A

CONFERENCE AREA

ENTRANCE

5205A

NURSE OFFICE

EYE

EXAM RM

5303A

EYE

EXAM RM

5308A

P-7B

ELEV.

P-9B

ELEV.

P-8B

ELEV.

P-10BELEV.

P-1A

ELEV.

P-4A

ELEV.

P-5A

CHARTING

OFFICE

STORAGE

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SYMBOLS LIST

HORIZONTAL EXIT PASSAGEWAY

EXIT

EXIT PASSAGEWAY

INDIANAPOLIS, IN 46224

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

SUITE DESIGNATION

PO

LK

S

TR

EE

T

DAMEN AVENUE

TA

YL

O R

S

TR

EE

T

11B

1B

1A

EXIT SIGN

EMERGENCY LIGHT

FIRE ALARM PULL STATION

FIRE ALARM CONTROL PANEL

POSITIVE PRESSURE ROOM 15%

NEGATIVE PRESSURE ROOM 15%

POSITIVE PRESSURE ROOM 30%

NEGATIVE PRESSURE ROOM 30%

PARTIAL FIFTH FLOOR PLAN

8.15.10.3 OF NFPA 13 2013 EDITION.

EXIT PASSAGEWAY PER SECTION 7.2.6 OF NFPA 101-2012

EDITION. UTILITIES INSTALLED ABOVE SUSPENDED

CEILING PRIOR TO THE CURRENT REQUIREMENTS NOW

FOUND IN SECTION 7.1.3.2.1(10) OF NFPA 101-2012 EDITION

AND FIRST ADOPTED IN THE 1985 EDITION.

ELECTRICAL UTILITY INSTALLED IN STAIRWAY PRIOR TO

THE CURRENT REQUIREMENTS NOW FOUND IN SECTION

7.1.3.2.1(10) OF NFPA 101-2012 EDITION AND FIRST

ADOPTED IN THE 1985 EDITION.

NOT AN EXIT. CIRCULATION STAIR ONLY.

FIRE RATED GLASS WALL-60 MINUTE RATED.

LOCKED FOR CLINICAL NEEDS OF THE PATIENTS PER

SECTION 19.2.2.2.5.1 OF NFPA 101-2012.

SINGLE EXIT ROOM. MAXIMUM 49 OCCUPANTS.

CONTINUOUS HINGE COVERING DOOR RATING PLATE.

FIRE ESCAPE LADDER PER SECTION 7.2.9 OF NFPA

101-2012 EDITION.

FIRE SPRINKLERS INSTALLED PER LIBRARY AND SHELVING

STORAGE SPACING REQUIREMENTS OF SECTION 8.5.10 OF

NFPA 13-2013 EDITION.

POWER OPERATED DOORS RELEASE UPON FIRE ALARM

SIGNAL.

ALTERNATING TREAD STAIR PER SECTION 7.2.11 OF NFPA

101-2012 EDITION.

FOAM ACOUSTICAL PANELS INSTALLED ON THE CEILINGS

HAVE A CLASS A SMOKE SPREAD AND SMOKE DENSITY

RATING ( SEE TECHNICAL DATA SHEET IN SOC BINDER)

PER THE ASTM E84 FIRE MATERIALS TEST AND AS

PERMITTED BY SECTION 18/19.3.3.2 OF NFPA 011-2015

EDITION.

NON SPRINKLERED PIPE SPACE PER SECTION 8.1.1 OF

NFPA 13.2013 EDITION

SPRINKLERS INSTALLED ABOVE AUDIO BOOTHS PER 1985

DIRECTIVE

EXISTING 3/16" MINIMUM STEEL PLATE FLOOR ACCESS

PANEL CONSIDERED EQUIVALENT TO 2 HOUR FLOOR

ASSEMBLY AT THE TIME OF BUILDING CONSTRUCTION.

NON-LABELED STEEL DOOR FRAMES WERE INSTALLED

PRIOR TO THE CURRENT LABELED DOOR FRAME

PARTIAL FIFTH FLOOR PLAN

BUILDING 11 & 30

FULLY SPRINKLERED; QUICK RESPONSE TYPE

BUSINESS OCCUPANCY

OUTPATIENT PSYCHIATRY

ROOF

SKYLIGHT ROOF

ROOF

ROOF

ROOF

ROOF

ROOF

ROOF

ROOF

TEL

62T1

SOCIAL

WORK

PSTD SOCIAL

WORKER

ELEC.

62E1

ELEC.

6277B

ELEC.

62E3

ELEC.

62E2

ELECTRICAL

63E1

ELECTRICAL

63E2

PHONE

FAC

6290B

GROUP

RM

RESEARCH

LAB

RESEARCH

LAB

GROUP

THERAPY

WAITING

GROUP THERAPY

LAB

62E4

EMS

LAB

RESEARCH

LAB

CORRIDOR

C6201

RESEARCH

LAB

FILE RM

FILE RM

CORRIDOR

C6203

CORRIDOR

C6202

CORRIDOR

C6205

PSTD

PSYCHIAST

MHICM VOC

REHAB

MHICM

OFFICE

MHICM

OFFICE

MHICM

OFFICE

MHICM

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

CYLINDER

RM

ELEVATOR

LOBBY

C6204

ELEV.

P5-A

ELEV.

ELEVATOR

S3-A

GLASS

WASH

LAB

LAB

CORRIDOR

C6207

CORRIDOR

C6206

MICRO

OFFICE

RESEARCH

LAB

LAB

RESEARCH

LAB

OFFICE

REFRIG

6254A

STAIR

NO-10

OFFICE

CONFERENCE RM

MULTI RM

STORAGE

OFFICE

LAB

6245A

RESEARCH

LAB

STORAGE

RESEARCH

LAB

RESEARCH

LAB

RESEARCH

LAB

ELEV.

P2-A

ELEV.

P1-A

STAIR

NO-11

COOL

LAB

OFFICE

OFFICE

OFFICE

OFFICE

IOINATION

TISSUE

CULTURE

6227 PSTD

PSYCHIATIST

PSY

FELLOW

PTSD

PSYCHIATIST

TEL

62T2

STAIR

NO-9

STER

GLASS

WASHING

OFFICE

OFFICE

WISE

OFFICE

FEMALE

TOILET

MALE TOILET

SUPPY

EMS

COMMON FREEZER RM

RESEARCH

LAB

RESEARCH

LAB

RESEARCH

OFFICE

RESEARCH OFFICE

OFFICE

OFFICE

OFFICE

STORAGE

STAIR

NO-12

RESEARCH

ADMIN

STORAGE

RESEARCH

LAB

CONFERENCE RM

OFFICE

OFFICE

OFFICE

SECY

OFFICE

ACOS

OFFICE

CORRIDOR

C6303

CORRIDOR

C6301

CORRIDOR

C6302

MENS

TOILET

WOMENS

TOILET

ELEV.

S10-B

ELEV.

P9-B

ELEV.

P8-B

HAC

PSY OFFICE

SOCIAL

WORK

PSY

OFFICE

NURSE OFFICE

STAIR

NO-6

GERIATRIC CLINIC

NURSE

PSY

OFFICE

PSY

OFFICE

PSY

OFFICE

SOCIAL

WORK

PSY

OFFICE

SOCIAL

WORK

GROUP

RM

MAIL/

COPIER

CHIEF

OFFICE

PSY

OFFICE

MH TECHNICIAN

PSY

OFFICE

SOCIAL

WORK

PSY

OFFICE

PSY

OFFICE

CORRIDOR

C6304

PSYCHIATRY

WAITING

WAITING

PSY

OFFICE

PSY

OFFICE

PSY

OFFICE

PSY

OFFICE

HAC

WOMENS

TOILET

MENS

TOILET

ELEV.

P7-B

ELEV.

P6

STAIR

NO-7

PSY

OFFICE

NURSE

OFFICE

PSY

OFFICE

PSY

OFFICE

PSY

OFFICE

PSY

OFFICE

PSY

OFFICE

SOCIAL

WORKER

OFFICE

PSY

FELLOW

PSY

FELLOW

PSY

OFFICE

PSY

OFFICE

NEURO

RESEARCH

NEURO

RESEARCH

STAIR

NO-8

ASSIST. CHIEF

FEC

UNISEX

STAFF

TOILET

6223A

FEC

FEC

FEC

REFR

WALK-IN

6250A

P4-A

VESTIBULE

COPIER RM

6290C

ELEC.

6277A

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SYMBOLS LIST

HORIZONTAL EXIT PASSAGEWAY

EXIT

EXIT PASSAGEWAY

INDIANAPOLIS, IN 46224

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

SUITE DESIGNATION

PO

LK

S

TR

EE

T

DAMEN AVENUE

TA

YL

O R

S

TR

EE

T

11B

1B

1A

EXIT SIGN

EMERGENCY LIGHT

FIRE ALARM PULL STATION

FIRE ALARM CONTROL PANEL

POSITIVE PRESSURE ROOM 15%

NEGATIVE PRESSURE ROOM 15%

POSITIVE PRESSURE ROOM 30%

NEGATIVE PRESSURE ROOM 30%

PARTIAL SIXTH FLOOR PLAN

8.15.10.3 OF NFPA 13 2013 EDITION.

EXIT PASSAGEWAY PER SECTION 7.2.6 OF NFPA 101-2012

EDITION. UTILITIES INSTALLED ABOVE SUSPENDED

CEILING PRIOR TO THE CURRENT REQUIREMENTS NOW

FOUND IN SECTION 7.1.3.2.1(10) OF NFPA 101-2012 EDITION

AND FIRST ADOPTED IN THE 1985 EDITION.

ELECTRICAL UTILITY INSTALLED IN STAIRWAY PRIOR TO

THE CURRENT REQUIREMENTS NOW FOUND IN SECTION

7.1.3.2.1(10) OF NFPA 101-2012 EDITION AND FIRST

ADOPTED IN THE 1985 EDITION.

NOT AN EXIT. CIRCULATION STAIR ONLY.

FIRE RATED GLASS WALL-60 MINUTE RATED.

LOCKED FOR CLINICAL NEEDS OF THE PATIENTS PER

SECTION 19.2.2.2.5.1 OF NFPA 101-2012.

SINGLE EXIT ROOM. MAXIMUM 49 OCCUPANTS.

CONTINUOUS HINGE COVERING DOOR RATING PLATE.

FIRE ESCAPE LADDER PER SECTION 7.2.9 OF NFPA

101-2012 EDITION.

FIRE SPRINKLERS INSTALLED PER LIBRARY AND SHELVING

STORAGE SPACING REQUIREMENTS OF SECTION 8.5.10 OF

NFPA 13-2013 EDITION.

POWER OPERATED DOORS RELEASE UPON FIRE ALARM

SIGNAL.

ALTERNATING TREAD STAIR PER SECTION 7.2.11 OF NFPA

101-2012 EDITION.

FOAM ACOUSTICAL PANELS INSTALLED ON THE CEILINGS

HAVE A CLASS A SMOKE SPREAD AND SMOKE DENSITY

RATING ( SEE TECHNICAL DATA SHEET IN SOC BINDER)

PER THE ASTM E84 FIRE MATERIALS TEST AND AS

PERMITTED BY SECTION 18/19.3.3.2 OF NFPA 011-2015

EDITION.

NON SPRINKLERED PIPE SPACE PER SECTION 8.1.1 OF

NFPA 13.2013 EDITION

SPRINKLERS INSTALLED ABOVE AUDIO BOOTHS PER 1985

DIRECTIVE

EXISTING 3/16" MINIMUM STEEL PLATE FLOOR ACCESS

PANEL CONSIDERED EQUIVALENT TO 2 HOUR FLOOR

ASSEMBLY AT THE TIME OF BUILDING CONSTRUCTION.

NON-LABELED STEEL DOOR FRAMES WERE INSTALLED

PRIOR TO THE CURRENT LABELED DOOR FRAME

PARTIAL SIXTH FLOOR PLAN

BUILDING 11 & 30

FULLY SPRINKLERED; QUICK RESPONSE TYPE

BUSINESS OCCUPANCY

BUILDING 30

ROOF

ROOF

ELECTRICAL

WOMENS

TOILET

QUARANTINE

RM

73E2

ELEV.

ELEC.

73E1

TEL

HAC

STERILIZER

7201A

STORAGE

72T1

7202A

ELEC.

72E4

ELEC.

72E3

ULTRA LIGHT

LAB

CORRIDOR

CORRIDOR

C7304

PROCEDURE RM

PROCEDURAL LAB

QUARANTINE RM

METABOLIC

SCRUB RM

OPERATING RM

WALK IN

COOLER

STORAGE

NECROPSY

PROCEDURE

RM

SUPPLY RM

OFFICE

MENS

TOILET

CORRIDOR

C7302

CORRIDOR

C7301

STERILIZER RM

ELEV.

P8-B

ELEV.

P9-B

ELEV.

S10-B

ELEV.

P7-B

ELEV.

P6

LOUNGE

CORRIDOR

C7303

ANIMAL

WARD

ANIMAL

WARD

ANIMAL

WARD

ANIMAL

WARD

ANIMAL

WARD

ANIMAL

WARD

ANIMAL WARD

ANIMAL WARD

LAB

LAB

CAGE WASHING

WARD-A

WARD-B

WARD-C

SUPERVISOR

PROCEDURAL

LAB

ANIMAL

TECH

MANAGER/

COORDINATOR

CLEAN CAGE

FEED AND BEDDING

ANIMAL WARD

ANIMAL WARD

ANIMAL WARD

ANIMAL WARD

STERILIZER

RESEARCH LAB

RESEARCH LAB

7282 REFR

ELECTRICAL

72E5

RESEARCH LAB

RESEARCH LAB

RESEARCH LAB

RESEARCH LAB

HAC

BREAK RM

STORAGE

STORAGE

OFFICE

OFFICE

OFFICE

CORRIDOR

C7203

CORRIDOR

C7202

CORRIDOR

C7205

CORRIDOR

C7204

ELEV.

P5-A

ELEV.

P4-A

ELEVATOR

S3-A

CORRIDOR

C7201

RESEARCH LAB RESEARCH LAB

OFFICE

ELEV.

P2-A

P1-A

CORRIDOR

C7305

TEL

72T2

RESEARCH LAB

OFFICE

GLASS

WASHING

STERILIZATION

GLASS WASHING

AND STERILIZATION

RESEARCH LAB

RESEARCH LAB

TISSUE

CULTURE

FEMALE

TOILET

MALE TOILET

STORAGE

EMS

FREEZER RM

RESEARCH LAB

RESEARCH LAB

ANTE

RM

CONTAINMENT LAB

STORAGE

CONTAINMENT LAB

CORRIDOR

OFFICE

OFFICE

RESEARCH LAB

OFFICE

7207A

OFFICE

TISSUE CULTURE

RESEARCH LAB

RESEARCH LAB

RESEARCH LAB

RESEARCH LAB

OFFICE

OFFICE

BREAK RM

OFFICE

RESEARCH LAB

RESEARCH LAB

RESEARCH LAB

RESEARCH LAB CONFERENCE RM

RESEARCH LAB

REFR

STORAGE

STORAGE

TISSUE

CULTURE

OFFICE

OFFICE

STORAGE

(Empty)

LOUNGE

RADIATION SAFETY

OFFICE

LAB

STAIR

NO 6

STAIR

NO 7

STAIR

NO 8

STAIR

NO 9

STAIR

NO 12

STAIR

NO 11

STAIR

NO 10

RADIATION

SAFETY

RESEARCH LAB

HAC

ELEC.

72E2

ELEC.

72E1

TELECOM

CLOSET

RESEARCH &

DEVELOPMENT

7284A

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SYMBOLS LIST

HORIZONTAL EXIT PASSAGEWAY

EXIT

EXIT PASSAGEWAY

INDIANAPOLIS, IN 46224

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

SUITE DESIGNATION

PO

LK

S

TR

EE

T

DAMEN AVENUE

TA

YL

O R

S

TR

EE

T

11B

1B

1A

EXIT SIGN

EMERGENCY LIGHT

FIRE ALARM PULL STATION

FIRE ALARM CONTROL PANEL

POSITIVE PRESSURE ROOM 15%

NEGATIVE PRESSURE ROOM 15%

POSITIVE PRESSURE ROOM 30%

NEGATIVE PRESSURE ROOM 30%

PARTIAL SEVENTH FLOOR PLAN

8.15.10.3 OF NFPA 13 2013 EDITION.

EXIT PASSAGEWAY PER SECTION 7.2.6 OF NFPA 101-2012

EDITION. UTILITIES INSTALLED ABOVE SUSPENDED

CEILING PRIOR TO THE CURRENT REQUIREMENTS NOW

FOUND IN SECTION 7.1.3.2.1(10) OF NFPA 101-2012 EDITION

AND FIRST ADOPTED IN THE 1985 EDITION.

ELECTRICAL UTILITY INSTALLED IN STAIRWAY PRIOR TO

THE CURRENT REQUIREMENTS NOW FOUND IN SECTION

7.1.3.2.1(10) OF NFPA 101-2012 EDITION AND FIRST

ADOPTED IN THE 1985 EDITION.

NOT AN EXIT. CIRCULATION STAIR ONLY.

FIRE RATED GLASS WALL-60 MINUTE RATED.

LOCKED FOR CLINICAL NEEDS OF THE PATIENTS PER

SECTION 19.2.2.2.5.1 OF NFPA 101-2012.

SINGLE EXIT ROOM. MAXIMUM 49 OCCUPANTS.

CONTINUOUS HINGE COVERING DOOR RATING PLATE.

FIRE ESCAPE LADDER PER SECTION 7.2.9 OF NFPA

101-2012 EDITION.

FIRE SPRINKLERS INSTALLED PER LIBRARY AND SHELVING

STORAGE SPACING REQUIREMENTS OF SECTION 8.5.10 OF

NFPA 13-2013 EDITION.

POWER OPERATED DOORS RELEASE UPON FIRE ALARM

SIGNAL.

ALTERNATING TREAD STAIR PER SECTION 7.2.11 OF NFPA

101-2012 EDITION.

FOAM ACOUSTICAL PANELS INSTALLED ON THE CEILINGS

HAVE A CLASS A SMOKE SPREAD AND SMOKE DENSITY

RATING ( SEE TECHNICAL DATA SHEET IN SOC BINDER)

PER THE ASTM E84 FIRE MATERIALS TEST AND AS

PERMITTED BY SECTION 18/19.3.3.2 OF NFPA 011-2015

EDITION.

NON SPRINKLERED PIPE SPACE PER SECTION 8.1.1 OF

NFPA 13.2013 EDITION

SPRINKLERS INSTALLED ABOVE AUDIO BOOTHS PER 1985

DIRECTIVE

EXISTING 3/16" MINIMUM STEEL PLATE FLOOR ACCESS

PANEL CONSIDERED EQUIVALENT TO 2 HOUR FLOOR

ASSEMBLY AT THE TIME OF BUILDING CONSTRUCTION.

NON-LABELED STEEL DOOR FRAMES WERE INSTALLED

PRIOR TO THE CURRENT LABELED DOOR FRAME

PARTIAL SEVENTH FLOOR PLAN

FULLY SPRINKLERED; QUICK RESPONSE TYPE

BUSINESS OCCUPANCY

8 FLOOR

8 FLOOR ROOF

8 FLOOR ROOF

8 FLOOR ROOF

8 FLOOR ROOF

8 FLOOR ROOF

ROOF

ROOF

ROOF

P200

P300

MECH RM

P300A

ELEV.

S10-B

ELEV.

P9-B

ELEV.

P8-B

STAIR

NO-7

ELEV.

P7-B

ELEV.

P6

P350

STAIR

NO-11

P5-A

ELEV.

P4-A

ELEVATOR

S3-A

ELEV.

P2-A

P1-A

ROOF

NON SPRINKLERED ELECTRICAL ROOM PER SECTION

8.15.10.3 OF NFPA 13 2013 EDITION.

EXIT PASSAGEWAY PER SECTION 7.2.6 OF NFPA 101-2012

EDITION. UTILITIES INSTALLED ABOVE SUSPENDED

CEILING PRIOR TO THE CURRENT REQUIREMENTS NOW

FOUND IN SECTION 7.1.3.2.1(10) OF NFPA 101-2012 EDITION

AND FIRST ADOPTED IN THE 1985 EDITION.

ELECTRICAL UTILITY INSTALLED IN STAIRWAY PRIOR TO

THE CURRENT REQUIREMENTS NOW FOUND IN SECTION

7.1.3.2.1(10) OF NFPA 101-2012 EDITION AND FIRST

ADOPTED IN THE 1985 EDITION.

NOT AN EXIT. CIRCULATION STAIR ONLY.

FIRE RATED GLASS WALL-60 MINUTE RATED.

LOCKED FOR CLINICAL NEEDS OF THE PATIENTS PER

SECTION 19.2.2.2.5.1 OF NFPA 101-2012.

SINGLE EXIT ROOM. MAXIMUM 49 OCCUPANTS.

CONTINUOUS HINGE COVERING DOOR RATING PLATE.

FIRE ESCAPE LADDER PER SECTION 7.2.9 OF NFPA

101-2012 EDITION.

FIRE SPRINKLERS INSTALLED PER LIBRARY AND SHELVING

STORAGE SPACING REQUIREMENTS OF SECTION 8.5.10 OF

NFPA 13-2013 EDITION.

POWER OPERATED DOORS RELEASE UPON FIRE ALARM

SIGNAL.

ALTERNATING TREAD STAIR PER SECTION 7.2.11 OF NFPA

101-2012 EDITION.

FOAM ACOUSTICAL PANELS INSTALLED ON THE CEILINGS

HAVE A CLASS A SMOKE SPREAD AND SMOKE DENSITY

RATING ( SEE TECHNICAL DATA SHEET IN SOC BINDER)

PER THE ASTM E84 FIRE MATERIALS TEST AND AS

PERMITTED BY SECTION 18/19.3.3.2 OF NFPA 011-2015

EDITION.

NON SPRINKLERED PIPE SPACE PER SECTION 8.1.1 OF

NFPA 13.2013 EDITION

SPRINKLERS INSTALLED ABOVE AUDIO BOOTHS PER 1985

DIRECTIVE

EXISTING 3/16" MINIMUM STEEL PLATE FLOOR ACCESS

PANEL CONSIDERED EQUIVALENT TO 2 HOUR FLOOR

ASSEMBLY AT THE TIME OF BUILDING CONSTRUCTION.

NON-LABELED STEEL DOOR FRAMES WERE INSTALLED

PRIOR TO THE CURRENT LABELED DOOR FRAME

PARTIAL EIGHTH FLOOR PLAN

FULLY SPRINKLERED; QUICK RESPONSE TYPE

INDUSTRIAL OCCUPANCY

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SYMBOLS LIST

HORIZONTAL EXIT PASSAGEWAY

EXIT

EXIT PASSAGEWAY

INDIANAPOLIS, IN 46224

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

SUITE DESIGNATION

PO

LK

S

TR

EE

T

DAMEN AVENUE

TA

YL

O R

S

TR

EE

T

11B

1B

1A

EXIT SIGN

EMERGENCY LIGHT

FIRE ALARM PULL STATION

FIRE ALARM CONTROL PANEL

POSITIVE PRESSURE ROOM 15%

NEGATIVE PRESSURE ROOM 15%

POSITIVE PRESSURE ROOM 30%

NEGATIVE PRESSURE ROOM 30%

PARTIAL 8 FLOOR PLAN

NO 7

NO 11

PARTIAL NINTH FLOOR PLAN

FULLY SPRINKLERED; STANDARD RESPONSE TYPE

INDUSTRIAL OCCUPANCY

NON SPRINKLERED ELECTRICAL ROOM PER SECTION

8.15.10.3 OF NFPA 13 2013 EDITION.

EXIT PASSAGEWAY PER SECTION 7.2.6 OF NFPA 101-2012

EDITION. UTILITIES INSTALLED ABOVE SUSPENDED

CEILING PRIOR TO THE CURRENT REQUIREMENTS NOW

FOUND IN SECTION 7.1.3.2.1(10) OF NFPA 101-2012 EDITION

AND FIRST ADOPTED IN THE 1985 EDITION.

ELECTRICAL UTILITY INSTALLED IN STAIRWAY PRIOR TO

THE CURRENT REQUIREMENTS NOW FOUND IN SECTION

7.1.3.2.1(10) OF NFPA 101-2012 EDITION AND FIRST

ADOPTED IN THE 1985 EDITION.

NOT AN EXIT. CIRCULATION STAIR ONLY.

FIRE RATED GLASS WALL-60 MINUTE RATED.

LOCKED FOR CLINICAL NEEDS OF THE PATIENTS PER

SECTION 19.2.2.2.5.1 OF NFPA 101-2012.

SINGLE EXIT ROOM. MAXIMUM 49 OCCUPANTS.

CONTINUOUS HINGE COVERING DOOR RATING PLATE.

FIRE ESCAPE LADDER PER SECTION 7.2.9 OF NFPA

101-2012 EDITION.

FIRE SPRINKLERS INSTALLED PER LIBRARY AND SHELVING

STORAGE SPACING REQUIREMENTS OF SECTION 8.5.10 OF

NFPA 13-2013 EDITION.

POWER OPERATED DOORS RELEASE UPON FIRE ALARM

SIGNAL.

ALTERNATING TREAD STAIR PER SECTION 7.2.11 OF NFPA

101-2012 EDITION.

FOAM ACOUSTICAL PANELS INSTALLED ON THE CEILINGS

HAVE A CLASS A SMOKE SPREAD AND SMOKE DENSITY

RATING ( SEE TECHNICAL DATA SHEET IN SOC BINDER)

PER THE ASTM E84 FIRE MATERIALS TEST AND AS

PERMITTED BY SECTION 18/19.3.3.2 OF NFPA 011-2015

EDITION.

NON SPRINKLERED PIPE SPACE PER SECTION 8.1.1 OF

NFPA 13.2013 EDITION

SPRINKLERS INSTALLED ABOVE AUDIO BOOTHS PER 1985

DIRECTIVE

EXISTING 3/16" MINIMUM STEEL PLATE FLOOR ACCESS

PANEL CONSIDERED EQUIVALENT TO 2 HOUR FLOOR

ASSEMBLY AT THE TIME OF BUILDING CONSTRUCTION.

NON-LABELED STEEL DOOR FRAMES WERE INSTALLED

PRIOR TO THE CURRENT LABELED DOOR FRAME

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SYMBOLS LIST

HORIZONTAL EXIT PASSAGEWAY

EXIT

EXIT PASSAGEWAY

INDIANAPOLIS, IN 46224

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

SUITE DESIGNATION

PO

LK

S

TR

EE

T

DAMEN AVENUE

TA

YL

O R

S

TR

EE

T

11B

1B

1A

EXIT SIGN

EMERGENCY LIGHT

FIRE ALARM PULL STATION

FIRE ALARM CONTROL PANEL

POSITIVE PRESSURE ROOM 15%

NEGATIVE PRESSURE ROOM 15%

POSITIVE PRESSURE ROOM 30%

NEGATIVE PRESSURE ROOM 30%

PARTIAL NINTH FLOOR PLAN

PIP

E T

UN

NE

L

PIP

E T

UN

NE

L

PIT P2

FIR

E P

UM

P R

M

ME

CH

R M

ST

AIR

NO

16 EL

EV

AT

OR

PIT

S2 0;S

;S2

EL

EV

AT

OR

PIT

P2

8;P

EL

EV

AT

OR

PIT

P2

3;P

;P2

ST

AIR

NO

PIP

E B

AS

EM

EN

T

B6

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SYMBOLS LIST

HORIZONTAL EXIT PASSAGEWAY

EXIT

EXIT PASSAGEWAY

INDIANAPOLIS, IN 46224

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

SUITE DESIGNATION

PO

LK

S

TR

EE

T

DAMEN AVENUE

TA

YL

O R

S

TR

EE

T

11B

1B

1A

EXIT SIGN

EMERGENCY LIGHT

FIRE ALARM PULL STATION

FIRE ALARM CONTROL PANEL

POSITIVE PRESSURE ROOM 15%

NEGATIVE PRESSURE ROOM 15%

POSITIVE PRESSURE ROOM 30%

NEGATIVE PRESSURE ROOM 30%

PARTIAL BASEMENT FLOOR PLAN

BUILDING 40

8.15.10.3 OF NFPA 13 2013 EDITION.

EXIT PASSAGEWAY PER SECTION 7.2.6 OF NFPA 101-2012

EDITION. UTILITIES INSTALLED ABOVE SUSPENDED

CEILING PRIOR TO THE CURRENT REQUIREMENTS NOW

FOUND IN SECTION 7.1.3.2.1(10) OF NFPA 101-2012 EDITION

AND FIRST ADOPTED IN THE 1985 EDITION.

ELECTRICAL UTILITY INSTALLED IN STAIRWAY PRIOR TO

THE CURRENT REQUIREMENTS NOW FOUND IN SECTION

7.1.3.2.1(10) OF NFPA 101-2012 EDITION AND FIRST

ADOPTED IN THE 1985 EDITION.

NOT AN EXIT. CIRCULATION STAIR ONLY.

FIRE RATED GLASS WALL-60 MINUTE RATED.

LOCKED FOR CLINICAL NEEDS OF THE PATIENTS PER

SECTION 19.2.2.2.5.1 OF NFPA 101-2012.

SINGLE EXIT ROOM. MAXIMUM 49 OCCUPANTS.

CONTINUOUS HINGE COVERING DOOR RATING PLATE.

FIRE ESCAPE LADDER PER SECTION 7.2.9 OF NFPA

101-2012 EDITION.

FIRE SPRINKLERS INSTALLED PER LIBRARY AND SHELVING

STORAGE SPACING REQUIREMENTS OF SECTION 8.5.10 OF

NFPA 13-2013 EDITION.

POWER OPERATED DOORS RELEASE UPON FIRE ALARM

SIGNAL.

ALTERNATING TREAD STAIR PER SECTION 7.2.11 OF NFPA

101-2012 EDITION.

FOAM ACOUSTICAL PANELS INSTALLED ON THE CEILINGS

HAVE A CLASS A SMOKE SPREAD AND SMOKE DENSITY

RATING ( SEE TECHNICAL DATA SHEET IN SOC BINDER)

PER THE ASTM E84 FIRE MATERIALS TEST AND AS

PERMITTED BY SECTION 18/19.3.3.2 OF NFPA 011-2015

EDITION.

NON SPRINKLERED PIPE SPACE PER SECTION 8.1.1 OF

NFPA 13.2013 EDITION

SPRINKLERS INSTALLED ABOVE AUDIO BOOTHS PER 1985

DIRECTIVE

EXISTING 3/16" MINIMUM STEEL PLATE FLOOR ACCESS

PANEL CONSIDERED EQUIVALENT TO 2 HOUR FLOOR

ASSEMBLY AT THE TIME OF BUILDING CONSTRUCTION.

NON-LABELED STEEL DOOR FRAMES WERE INSTALLED

PRIOR TO THE CURRENT LABELED DOOR FRAME

PARTIAL BASEMENT FLOOR PLAN

FULLY SPRINKLERED; MIXED RESPONSE TYPE

INDUSTRIAL OCCUPANCY

PA

TIO

ST

AR

BU

CK

S

EN

TR

AN

CE

C

OR

RI

DO

R

TO

BU

ILD

IN

G

, 1

1A , 1

1B

LO

UV

ER

RA

DIO

LO

GY

CO

UR

TY

AR

D

FE

C

FE

C

FE

C

FE

C

FE

C

AT

M

PA

T

CL

OT

H

CL

OS

ET

CL

OS

ET

FA

C

B

CL

OS

ET

B

E5

EL

EC

TR

IC

AL

E4

EN

TR

AN

CE

/LO

BB

Y C1

CO

RR

ID

OR

C1

W

AI

TI

NG

R M

SU

PV

BL

OO

D

DR

AW

OF

FI

CE

A

MU

LT

I

PU

RP

OS

E

RM

63 PA

TH

SU

PP

LY

B

OU

TP

AT

IE

NT

SP

EC

IM

EN

LA

B

C

OU

TP

AT

IE

NT

RA

DI

OL

OG

Y

W

AI

TI

NG

A

RE

A

RR

ID

OR

OU

TP

AT

IE

NT

RA

DI

OL

OG

Y

EX

AM

TR

EA

TM

EN

T

RM

CO

NT

RO

L R

M

OU

TP

AT

IE

NT

RA

DI

OL

OG

Y

EX

AM

TR

EA

TM

EN

T

RM

A

FI

RE

R

IS

ER

A

DR

ES

SI

NG

R M

B

DR

ES

SI

NG

R

M

C

MR

I

CO

NT

RO

L R

M

VE

ST

IB

UL

E C1

CO

RR

ID

OR

C1

PO

LIC

E

OP

ER

AT

IO

N

CO

RR

ID

OR

C1

CO

RR

ID

OR

C1

CO

RR

ID

OR

C1

SO

ILE

D

UT

ILI

TY

HO

LD

IN

G

RM 16

HO

LD

IN

G

RM 16

HO

LD

IN

G

RM 16

OF

FI

CE

CL

EA

N

SU

PP

LY

VE

ST

IB

UL

E

EL

EC

TR

IC

AL

RM 16

E1

MI

NO

R

PR

OC

ED

UR

E

ST

AI

R

NO

GR

OU

P

RM 16

ME

CH

P

UM

P

RM

FI

RE

P

UM

P

RM

PA

T

TO

ILE

T

81PA

NT

RY

CL

EA

N

SU

PP

LY

EX

IT

C

OR

RI

DO

R

ST

OR 16

PA

T

CL

IN

IC

PA

T

CL

IN

IC

HO

LD

IN

G

RM 16

HO

LD

IN

G

RM 16

HO

LD

IN

G

RM 16

HO

LD

IN

G

RM 16

HO

LD

IN

G

RM 16

HO

LD

IN

G

RM 16

HO

LD

IN

G

RM 16

HO

LD

IN

G

RM 16

HO

LD

IN

G

RM 16

HA

C

H3

EL

EV

AT

OR

LO

BB

Y C1

W

AS

TE

R

M

GA

S

CY

LIN

DE

R

ST

OR

AG

E

EM

S

CL

EA

N

SU

PP

LY

RE

CE

IV

IN

G

H1

HA

C

H2

CO

RR

ID

OR

C1

ST

AI

R

NO

EL

EV

AT

OR

NO

EL

EV

AT

OR

NO

EL

EV

AT

OR

NO

ME

NS

S

TA

FF

LO

CK

ER

W

OM

EN

S

ST

AF

F

LO

CK

ER

SH

OW

ER

B

TO

ILE

T

A

VE

ST

IB

UL

E

A

VE

ST

IB

UL

E

A

EM

S

ST

OR

AG

E

B

VE

ST

IB

UL

E

A

EM

S

OF

FI

CE

CO

MM

R M

T1

CO

MM

R M

T1

A

LIN

EN

CH

UT

E

RM

L1

TO

ILE

T

A

SH

OW

ER

B

VE

ST

IB

UL

E

VE

ST

IB

UL

E

ST

AF

F

LO

UN

GE

ST

AF

F

TO

ILE

T

A

PA

T

TO

ILE

T

EL

EV

AT

OR

LO

BB

Y C1

NU

RS

E

ST

AT

IO

N

ME

D

RM

A

PA

T

TO

ILE

T

CL

EA

N

LIN

EN

EL

EV

AT

OR

NO

EL

EV

AT

OR

NO

ST

AI

R

NO

MI

NO

R

PR

OC

ED

UR

E

ST

OR

AG

E

EL

EV

AT

OR

MA

CH

R M

A

CO

NS

UL

T

RM 16

A

VE

ST

IB

UL

E

CO

NS

UL

T

RM 16

B

CO

NS

UL

T

RM 16

EL

EC

TR

IC

AL

RM 16

E2

SU

RG

Y

FA

MI

LY

W

AI

TI

NG

RE

GI

ST

RA

TI

ON

SU

RG

Y

RE

CE

PT

IO

N

EL

EV

AT

OR

LO

BB

Y C1

EL

EV

AT

OR

NO

EL

EV

AT

OR

NO

EL

EV

AT

OR

NO

W

OM

EN

S

TO

ILE

T

PR

EP

AR

AT

IO

N

SO

ILE

D

RE

CE

IV

IN

G

DE

CO

NT

AM

SP

S

CH

IE

F

SP

S

ST

AF

F

OF

FI

CE

ST

ER

ILE

S

UP

PL

Y

ST

OR

AG

E

AN

D

DI

ST

BU

LK

ST

OR

AG

E

ST

AF

F

LO

CK

ER

TO

ILE

T

A

ST

AF

F

LO

CK

ER

43 TO

ILE

T

A

ST

AF

F

LO

UN

GE

ET

O

SV

C

ET

O

RM 16

A

HA

C

H6

CA

RT

S

TA

GI

NG

AR

EA

A

CA

RT

W

AS

H

HA

C

H4

TE

LE

PH

ON

E

AL

CO

VE

MA

LE

T

OI

LE

T

VE

ND

IN

G

MA

CH

S

CH

AP

LA

IN

OF

FI

CE

CH

IE

F

CH

AP

LA

IN

EL

EV

AT

OR

PI

T

P-

EL

EC

TR

IC

AL

R

M

E1

EL

EV

AT

OR

MA

CH

R M

SE

CU

RE

D

IT

EM

S

W

HE

EL

CH

AI

R

W

AS

H

ES

CO

RT

W

AI

TI

NG

R

M

FI

RE

C

OM

MA

ND

CE

NT

ER

ST

AI

R

NO

SE

CY

06 VE

ST

IB

UL

E

BL

ES

SE

D

SA

CR

AM

EN

T

CH

AP

EL

SA

CR

IS

TY

05CO

RR

ID

OR

C1

7EL

EV

AT

OR

P-

HA

C

H5

TO

ILE

T

ST

AF

F

LO

CK

ER

ST

AF

F

LO

UN

GE

ST

AF

F

LO

CK

ER

TO

ILE

T

MA

NU

AL

EQ

UI

P

W

AS

H

AR

MO

RY

R

M

TO

ILE

T

ST

OR

AG

E

B

SQ

UA

D

RM

O

FF

IC

E

OF

FI

CE

A

EV

ID

EN

CE

OF

FI

CE

V

IE

W

A

IN

VE

ST

IG

AT

IO

N

SE

CT

IO

N

DE

PU

TY

C

HI

EF

VE

ST

IB

UL

E

SE

CY

O

FF

IC

E

41OF

FI

CE

CO

PI

ER

A

CO

RR

ID

OR

C1

PO

LIC

E

CH

IE

F

RA

D

EX

AM

DO

CT

OR

OF

FI

CE

RA

D

OF

FI

CE

UL

TR

AS

OU

ND

HO

LD

CE

LL

HO

LD

CE

LL

RA

DI

OL

OG

Y

OF

FI

CE

RA

DI

OL

OG

Y

RE

AD

IN

G

RM

RA

DI

OL

OG

Y

OF

FI

CE

RA

D

OF

FI

CE

UL

TR

AS

OU

ND

TO

ILE

T

SP

S

SU

PV

OF

FI

CE

SP

S

RE

CE

IV

IN

G

ST

OR

AG

E

SE

CY

O

FF

IC

E

RA

DI

OL

OG

Y

SV

C

CO

NF

ER

EN

CE

R

M

FA

N

RM

PA

CS

MA

NA

GE

R

CO

MP

UT

ER

CA

BI

NE

T

A

AD

MI

N

OF

FI

CE

CH

IE

F

RA

DI

OL

OG

Y

EL

EC

TR

IC

AL

CL

OS

ET

E2

TE

LE

PH

ON

E

CL

OS

ET

T1

HA

C

ST

AI

R

NO

W

AI

TI

NG

R M

CO

NS

UL

T

RM

CO

NS

UL

T

RM

BR

EA

K

RO

OM

FI

LE

S

RE

FR

IG

RE

CE

PT

IO

N

TE

CH

W

OR

K

TO

ILE

T

BR

EA

K

RO

OM

IN

PT

HO

LD

IN

G

CO

RR

ID

OR

C1

CO

RR

ID

OR

C1

CL

EA

N

CT

IM

AG

IN

G

RM

CO

NT

RO

L R

M

- 2

B

TO

ILE

T

A

CO

NT

RO

L R

M

- 1

A

TO

ILE

T

B

CT

IM

AG

IN

G

RM

EL

EC

TR

IC

AL

R

M

E3

DI

GI

TA

L R

AD

IO

LO

GY

EC

TR

IC

AL

VE

ST

IB

UL

E

CL

OS

ET

SA

LL

Y

PO

RT

VE

ST

IB

UL

E

DI

NN

IN

G

SP

AC

E

ST

EA

M

ST

ER

ILI

ZE

R

GYPH

ON

E

CL

OS

ET

A

B

A

A

A

6A

SU

PO

LIC

E

OF

FI

CE

CO

NS

UL

T

RM 16

A

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SYMBOLS LIST

HORIZONTAL EXIT PASSAGEWAY

EXIT

EXIT PASSAGEWAY

INDIANAPOLIS, IN 46224

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

SUITE DESIGNATION

PO

LK

S

TR

EE

T

DAMEN AVENUE

TA

YL

O R

S

TR

EE

T

11B

1B

1A

EXIT SIGN

EMERGENCY LIGHT

FIRE ALARM PULL STATION

FIRE ALARM CONTROL PANEL

POSITIVE PRESSURE ROOM 15%

NEGATIVE PRESSURE ROOM 15%

POSITIVE PRESSURE ROOM 30%

NEGATIVE PRESSURE ROOM 30%

PARTIAL FIRST FLOOR PLAN

8.15.10.3 OF NFPA 13 2013 EDITION.

EXIT PASSAGEWAY PER SECTION 7.2.6 OF NFPA 101-2012

EDITION. UTILITIES INSTALLED ABOVE SUSPENDED

CEILING PRIOR TO THE CURRENT REQUIREMENTS NOW

FOUND IN SECTION 7.1.3.2.1(10) OF NFPA 101-2012 EDITION

AND FIRST ADOPTED IN THE 1985 EDITION.

ELECTRICAL UTILITY INSTALLED IN STAIRWAY PRIOR TO

THE CURRENT REQUIREMENTS NOW FOUND IN SECTION

7.1.3.2.1(10) OF NFPA 101-2012 EDITION AND FIRST

ADOPTED IN THE 1985 EDITION.

NOT AN EXIT. CIRCULATION STAIR ONLY.

FIRE RATED GLASS WALL-60 MINUTE RATED.

LOCKED FOR CLINICAL NEEDS OF THE PATIENTS PER

SECTION 19.2.2.2.5.1 OF NFPA 101-2012.

SINGLE EXIT ROOM. MAXIMUM 49 OCCUPANTS.

CONTINUOUS HINGE COVERING DOOR RATING PLATE.

FIRE ESCAPE LADDER PER SECTION 7.2.9 OF NFPA

101-2012 EDITION.

FIRE SPRINKLERS INSTALLED PER LIBRARY AND SHELVING

STORAGE SPACING REQUIREMENTS OF SECTION 8.5.10 OF

NFPA 13-2013 EDITION.

POWER OPERATED DOORS RELEASE UPON FIRE ALARM

SIGNAL.

ALTERNATING TREAD STAIR PER SECTION 7.2.11 OF NFPA

101-2012 EDITION.

FOAM ACOUSTICAL PANELS INSTALLED ON THE CEILINGS

HAVE A CLASS A SMOKE SPREAD AND SMOKE DENSITY

RATING ( SEE TECHNICAL DATA SHEET IN SOC BINDER)

PER THE ASTM E84 FIRE MATERIALS TEST AND AS

PERMITTED BY SECTION 18/19.3.3.2 OF NFPA 011-2015

EDITION.

NON SPRINKLERED PIPE SPACE PER SECTION 8.1.1 OF

NFPA 13.2013 EDITION

SPRINKLERS INSTALLED ABOVE AUDIO BOOTHS PER 1985

DIRECTIVE

EXISTING 3/16" MINIMUM STEEL PLATE FLOOR ACCESS

PANEL CONSIDERED EQUIVALENT TO 2 HOUR FLOOR

ASSEMBLY AT THE TIME OF BUILDING CONSTRUCTION.

NON-LABELED STEEL DOOR FRAMES WERE INSTALLED

PRIOR TO THE CURRENT LABELED DOOR FRAME

PARTIAL FIRST FLOOR PLAN

FULLY SPRINKLERED; QUICK RESPONSE TYPE

AMBULATORY HEALTHCARE OCCUPANCY

EL

EC

E2

EL

EC

E1

CL

OS

ET

CL

OS

ET

CL

OS

ET

FA

C

ME

CH

R M

A

ST

OR

AG

E

B

AN

ES

T

RE

SI

DE

NT

OF

FI

CE

-3

CO

RR

ID

OR

C2

CO

RR

ID

OR

C2

CO

RR

ID

OR

C2

CO

NN

EC

TI

NG

CO

RR

ID

OR

C2

CO

RR

ID

OR

C2

CO

RR

ID

OR

C2

CO

RR

ID

OR

C2

CO

RR

ID

OR

C2

CO

RR

ID

OR

C2

EL

EV

AT

OR

P2

EL

EV

AT

OR

P2

EL

EV

AT

OR

P2

EL

EC

TR

IC

AL

RM 26

E1

AN

ES

T W

OR

K

SA

TE

LL

IT

E

PH

AR

MA

CY

HO

LD

IN

G

BA

Y

CO

RR

ID

OR

C2

EL

EC

TR

IC

AL

RM 26

E3

HO

LD

IN

G

BA

Y

HO

LD

IN

G

BA

Y

HO

LD

IN

G

BA

Y

EL

EV

AT

OR

P2

EL

EV

AT

OR

P2

ST

AI

R

ST

-1

HA

C

H4

TO

ILE

T

B

LO

CK

ER

TO

ILE

T

A

AN

ES

T

SV

C

SE

CY

OF

FI

CE

OF

FI

CE

-1

AN

ES

TH

ES

IO

LO

GY

AT

TE

ND

IN

G

OF

FI

CE

-2

AN

ES

TH

ES

IO

LO

GY

AT

TE

ND

IN

G

OF

FI

CE

-4

AN

ES

T

TE

CH

S

OF

FI

CE

ST

OR

AG

E

75AN

ES

TH

ES

IO

LO

GY

AT

TE

ND

IN

G

OF

FI

CE

-5

CR

NA

OF

FI

CE

-6

AN

ES

T

AD

MI

N

OF

FI

CE

R

SU

RG

IC

AL

SV

C

OF

FI

CE

-8

SU

RG

IC

AL

SV

C

OF

FI

CE

-9

ST

AI

R

NO

OF

FI

CE

TO

ILE

T

NU

RS

E

ST

AT

IO

N

NU

RS

E

ST

AT

IO

N

NU

RS

E

ST

AT

IO

N

NU

RS

E

ST

AT

IO

N

NU

RS

E

ST

AT

IO

N

HO

LD

IN

G

BA

Y

HO

LD

IN

G

BA

Y

HO

LD

IN

G

BA

Y

HO

LD

IN

G

BA

Y

CL

EA

N

SU

PP

Y

HO

LD

IN

G

RM 26

HO

LD

IN

G

RM 26

HO

LD

IN

G

RM 26

HO

LD

IN

G

RM 26

IS

OL

AT

IO

N

HO

LD

IN

G

RM 26

SO

ILE

D

UT

ILI

TY

TO

ILE

T

HA

C

H3

DI

CT

AT

IO

N

D

ST

AF

F

LO

UN

GE

TO

ILE

T

A

TO

ILE

T

B

TO

ILE

T

C

CY

ST

OS

CO

PY

R

M

CY

ST

O

CL

EA

N

UP

R

M

A

CY

ST

O

ST

OR

AG

E

B

OR

-7

OR

-6

EL

EV

AT

OR

NO

ST

ER

ILE

C

OR

E

AN

NE

X

ST

AI

R

NO

OR

-5

EL

EC

TR

IC

AL

RM 26

E2

ST

ER

ILE

CO

RE

EL

EV

AT

OR

NO

RE

CY

CL

IN

G

CO

NT

RO

L

ST

AT

IO

N

SO

ILE

D

UT

ILI

TY

ST

OR

AG

E

EM

S

H2

AL

CO

VE

CO

MM

R M

T1

A

CO

MM

R

M

T1

LIN

EN

CH

UT

E

L1

OF

FI

CE

ST

OR

AG

E

EQ

UI

P

ST

OR

AG

E

EQ

UI

P

ST

OR

AG

E

CL

EA

N

LIN

EN

HA

C

H1

VE

ST

IB

UL

E

OR

S

UP

PO

RT

OR

-3

(L

AR

GE

OR

-4

(L

AR

GE

OR

-2

(L

AR

GE

OR

-1

(L

AR

GE

OR

S

UP

PO

RT

VE

ST

IB

UL

E

ST

AI

R

ST

-1

4 EL

EV

AT

OR

S2

EL

EV

AT

OR

S2

EL

EV

AT

OR

S2

OR

S

UP

PO

RT

PH

YS

IC

AL

TH

ER

AP

Y

CL

IN

IC

CO

RR

ID

OR

C2

CO

RR

ID

OR

C2

KI

NE

SI

OT

HE

RA

PY

C

LIN

IC

ST

OR

AG

E

ME

NS

TO

ILE

T

LO

CK

ER

A ME

NS

TO

ILE

T

PA

TI

EN

T

RM

W

OM

EN

S

LO

CK

ER 25

HA

C

W

OM

EN

S

TO

ILE

T

TO

ILE

T

A

OF

FI

CE

S

TA

FF

ST

AI

R

NO

W

OR

K

RM

OF

FI

CE

PM

A

ND

R

SE

CY

S

TA

FF

PM

A

ND

R

CH

IE

F

RE

SI

DE

NT

OF

FI

CE

CO

RR

ID

OR

C2

ST

OR

AG

E

ST

OR

AG

E

08 IR

M

ST

OR

AG

E

IR

M

ST

OR

AG

E

W

AI

TI

NG

R M

OF

FI

CE

A

A 25

B

C

IR

M

ST

OR

AG

E

IR

M

ST

OR

AG

E

IR

M

ST

OR

AG

E

FU

TU

RE

CO

RR

ID

OR

UN

AS

SI

GN

ED

ST

ER

ILE

MA

CH

ST

ER

ILE

MA

CH

CA

NT

EE

N

ST

OR

AG

E

A

GL

AS

S

CA

NO

PY

LO

BB

Y

EL

EV

AT

OR

PN

EU

MA

TI

C

TU

BE

CA

NO

PY

VE

ST

IB

UL

E

CO

NC

RE

TE

RE

CE

IV

IN

G

CA

RT

EL

EV

AT

OR

(M

AI

N

LO

BB

Y)

OP

EN

T O

BE

LO

W

GL

AS

S

CA

NO

PY

OP

EN

T O

BE

LO

W

LO

BB

Y

SH

EL

F

PA

RK

IN

G

EQ

UI

PM

EN

T

EQ

UI

PM

EN

TPA

RK

IN

G

PA

RK

IN

G

EQ

UI

PM

EN

T

ST

RE

TC

HPA

RK

IN

G

ST

RE

TC

H

PA

RK

IN

G

ST

RE

TC

H

PA

RK

IN

G

ST

RE

TC

H

ST

RE

TC

HPA

RK

IN

G

PA

RK

IN

G

PA

RK

IN

G

ST

RE

TC

H

PA

RK

IN

G

EQ

UI

PM

EN

T

PA

RK

IN

G

EQ

UI

PM

EN

T

PA

RK

IN

G

EQ

UI

PM

EN

T

PA

RK

IN

G

EQ

UI

PM

EN

T

PA

RK

IN

G

EQ

UI

PM

EN

T

EQ

UI

PM

EN

T

PA

RK

IN

G

EQ

UI

PM

EN

T

PA

RK

IN

G

PA

RK

IN

GEQ

UI

PM

EN

T

PA

RK

IN

GST

RE

TC

H

ST

RE

TC

H

EQ

UI

PM

EN

T

PA

RK

IN

G

EQ

UI

PM

EN

T

PA

RK

IN

G

PA

RK

IN

G

EQ

UI

PM

EN

T

PA

RK

IN

G

PA

RK

IN

G

EQ

UI

PM

EN

T

EQUIPMENT PARKING

EQUIPMENT PARKING

EQUIPMENT PARKING

RO

OF

OPEN TO BELOW

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SYMBOLS LIST

HORIZONTAL EXIT PASSAGEWAY

EXIT

EXIT PASSAGEWAY

INDIANAPOLIS, IN 46224

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

SUITE DESIGNATION

PO

LK

S

TR

EE

T

DAMEN AVENUE

TA

YL

O R

S

TR

EE

T

11B

1B

1A

EXIT SIGN

EMERGENCY LIGHT

FIRE ALARM PULL STATION

FIRE ALARM CONTROL PANEL

POSITIVE PRESSURE ROOM 15%

NEGATIVE PRESSURE ROOM 15%

POSITIVE PRESSURE ROOM 30%

NEGATIVE PRESSURE ROOM 30%

PARTIAL SECOND FLOOR PLAN

8.15.10.3 OF NFPA 13 2013 EDITION.

EXIT PASSAGEWAY PER SECTION 7.2.6 OF NFPA 101-2012

EDITION. UTILITIES INSTALLED ABOVE SUSPENDED

CEILING PRIOR TO THE CURRENT REQUIREMENTS NOW

FOUND IN SECTION 7.1.3.2.1(10) OF NFPA 101-2012 EDITION

AND FIRST ADOPTED IN THE 1985 EDITION.

ELECTRICAL UTILITY INSTALLED IN STAIRWAY PRIOR TO

THE CURRENT REQUIREMENTS NOW FOUND IN SECTION

7.1.3.2.1(10) OF NFPA 101-2012 EDITION AND FIRST

ADOPTED IN THE 1985 EDITION.

NOT AN EXIT. CIRCULATION STAIR ONLY.

FIRE RATED GLASS WALL-60 MINUTE RATED.

LOCKED FOR CLINICAL NEEDS OF THE PATIENTS PER

SECTION 19.2.2.2.5.1 OF NFPA 101-2012.

SINGLE EXIT ROOM. MAXIMUM 49 OCCUPANTS.

CONTINUOUS HINGE COVERING DOOR RATING PLATE.

FIRE ESCAPE LADDER PER SECTION 7.2.9 OF NFPA

101-2012 EDITION.

FIRE SPRINKLERS INSTALLED PER LIBRARY AND SHELVING

STORAGE SPACING REQUIREMENTS OF SECTION 8.5.10 OF

NFPA 13-2013 EDITION.

POWER OPERATED DOORS RELEASE UPON FIRE ALARM

SIGNAL.

ALTERNATING TREAD STAIR PER SECTION 7.2.11 OF NFPA

101-2012 EDITION.

FOAM ACOUSTICAL PANELS INSTALLED ON THE CEILINGS

HAVE A CLASS A SMOKE SPREAD AND SMOKE DENSITY

RATING ( SEE TECHNICAL DATA SHEET IN SOC BINDER)

PER THE ASTM E84 FIRE MATERIALS TEST AND AS

PERMITTED BY SECTION 18/19.3.3.2 OF NFPA 011-2015

EDITION.

NON SPRINKLERED PIPE SPACE PER SECTION 8.1.1 OF

NFPA 13.2013 EDITION

SPRINKLERS INSTALLED ABOVE AUDIO BOOTHS PER 1985

DIRECTIVE

EXISTING 3/16" MINIMUM STEEL PLATE FLOOR ACCESS

PANEL CONSIDERED EQUIVALENT TO 2 HOUR FLOOR

ASSEMBLY AT THE TIME OF BUILDING CONSTRUCTION.

NON-LABELED STEEL DOOR FRAMES WERE INSTALLED

PRIOR TO THE CURRENT LABELED DOOR FRAME

PARTIAL SECOND FLOOR PLAN

FULLY SPRINKLERED; MIXED RESPONSE TYPE

HEALTHCARE OCCUPANCY

RO

OF

RO

OF

RO

OF

RO

OF

RO

OF

ST

OR

AG

E

A

ST

OR

AG

E

B

RE

ST

R M

NI

C

TE

LE

CO

M

EL

EC

TR

IC

AL

U

TIL

ITY

M

EC

H

UT

ILI

TY

M

EC

H

EL

EC

TR

IC

AL

CL

OS

ET

E9

ST

AIR

NO

E7

UT

ILI

TY

EL

EC

TR

IC

AL

E6

UT

ILI

TY

EL

EC

TR

IC

AL

E5

TO

ILE

T

EL

EV

AT

OR

P-

EL

EV

AT

OR

P-

EL

EV

AT

OR

P-

FO

RE

MA

N

OF

FIC

E

EL

EC

TR

IC

AL

C

LO

SE

T

E4

UT

ILI

TY

EL

EC

TR

IC

AL

E3

ST

AIR

NO

EL

EC

TR

IC

AL

CL

OS

ET

E2

EL

EC

TR

IC

AL

CL

OS

ET

E1

UT

ILI

TY

M

EC

H

RE

VE

RS

E O

SM

OS

IS

RM

ME

CH

AN

IC

PN

EU

MA

TIC

TU

BE

R M

CO

RR

ID

OR

C3

TE

LE

CO

M

CL

OS

ET

T1

ST

AIR

NO

2N D

ME

ZZ

AN

IN

E

CO

RR

ID

OR

C3

EL

EV

AT

OR

P-

EL

EV

AT

OR

P-

EL

EV

AT

OR

P-

CO

RR

ID

OR

C3

CO

RR

ID

OR

C3

CO

RR

ID

OR

C3

PH

AR

MA

CY

NA

RC

OT

IC

VA

UL

T N

IC

SU

PV

CL

EA

N

RM

DR

UG

AR

EA

ME

CH

R M

FR

EE

ZE

R

ST

AG

IN

G

AR

EA

37 RE

FR

-1

RE

FR

-2

E1

ST

AIR NO

OF

FIC

E /

ST

OR

AG

E

CA

N

FO

OD

ST

OR

AG

E

FO

OD

M

GN

T

FO

OD

O

PE

R

AU

T

SE

RV

IN

G 35

CO

RR

ID

OR

C3

CO

RR

ID

OR

C3

CO

NF

ER

EN

CE

RO

OM

SU

PV

O

FF

IC

E

SU

PV

O

FF

IC

E

RE

FR

W

AL

K-

IN

ME

NS

TO

ILE

T

C

HA

LL

35 RE

FR

A

RE

FR

BR

EA

K R

OO

M

HA

LL

EL

EC

TR

IC

AL

FE

C

VE

ST

IBU

LE

A

VE

ST

IBU

LE

C

AL

CO

VE

B

CL

OS

ET

AVE

ST

IBU

LE

C3

EL

EC

TR

IC

AL

C

LO

SE

T

ME

CH

H E

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SYMBOLS LIST

HORIZONTAL EXIT PASSAGEWAY

EXIT

EXIT PASSAGEWAY

INDIANAPOLIS, IN 46224

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

SUITE DESIGNATION

PO

LK

S

TR

EE

T

DAMEN AVENUE

TA

YL

O R

S

TR

EE

T

11B

1B

1A

EXIT SIGN

EMERGENCY LIGHT

FIRE ALARM PULL STATION

FIRE ALARM CONTROL PANEL

POSITIVE PRESSURE ROOM 15%

NEGATIVE PRESSURE ROOM 15%

POSITIVE PRESSURE ROOM 30%

NEGATIVE PRESSURE ROOM 30%

PARTIAL THIRD FLOOR PLAN

8.15.10.3 OF NFPA 13 2013 EDITION.

EXIT PASSAGEWAY PER SECTION 7.2.6 OF NFPA 101-2012

EDITION. UTILITIES INSTALLED ABOVE SUSPENDED

CEILING PRIOR TO THE CURRENT REQUIREMENTS NOW

FOUND IN SECTION 7.1.3.2.1(10) OF NFPA 101-2012 EDITION

AND FIRST ADOPTED IN THE 1985 EDITION.

ELECTRICAL UTILITY INSTALLED IN STAIRWAY PRIOR TO

THE CURRENT REQUIREMENTS NOW FOUND IN SECTION

7.1.3.2.1(10) OF NFPA 101-2012 EDITION AND FIRST

ADOPTED IN THE 1985 EDITION.

NOT AN EXIT. CIRCULATION STAIR ONLY.

FIRE RATED GLASS WALL-60 MINUTE RATED.

LOCKED FOR CLINICAL NEEDS OF THE PATIENTS PER

SECTION 19.2.2.2.5.1 OF NFPA 101-2012.

SINGLE EXIT ROOM. MAXIMUM 49 OCCUPANTS.

CONTINUOUS HINGE COVERING DOOR RATING PLATE.

FIRE ESCAPE LADDER PER SECTION 7.2.9 OF NFPA

101-2012 EDITION.

FIRE SPRINKLERS INSTALLED PER LIBRARY AND SHELVING

STORAGE SPACING REQUIREMENTS OF SECTION 8.5.10 OF

NFPA 13-2013 EDITION.

POWER OPERATED DOORS RELEASE UPON FIRE ALARM

SIGNAL.

ALTERNATING TREAD STAIR PER SECTION 7.2.11 OF NFPA

101-2012 EDITION.

FOAM ACOUSTICAL PANELS INSTALLED ON THE CEILINGS

HAVE A CLASS A SMOKE SPREAD AND SMOKE DENSITY

RATING ( SEE TECHNICAL DATA SHEET IN SOC BINDER)

PER THE ASTM E84 FIRE MATERIALS TEST AND AS

PERMITTED BY SECTION 18/19.3.3.2 OF NFPA 011-2015

EDITION.

NON SPRINKLERED PIPE SPACE PER SECTION 8.1.1 OF

NFPA 13.2013 EDITION

SPRINKLERS INSTALLED ABOVE AUDIO BOOTHS PER 1985

DIRECTIVE

EXISTING 3/16" MINIMUM STEEL PLATE FLOOR ACCESS

PANEL CONSIDERED EQUIVALENT TO 2 HOUR FLOOR

ASSEMBLY AT THE TIME OF BUILDING CONSTRUCTION.

NON-LABELED STEEL DOOR FRAMES WERE INSTALLED

PRIOR TO THE CURRENT LABELED DOOR FRAME

PARTIAL THIRD FLOOR PLAN

INDUSTRIAL OCCUPANCY

BL

DG

ZO

NE

PA

RK

EQ

UI

P

PA

RK

EQ

UI

P

PA

RK

IN

G

ST

RE

TC

HE

R

T V

PA

TH

OL

OG

Y

LA

BO

RA

TO

RY

ME

DI

CI

NE

LA

B(

PA

TH

OL

OG

Y)

PA

RK

IN

G

ST

RE

TC

HE

R

PAA

RK

EQQ

UIP

K

PA

RKP

EQ

UI

P

BL

DG

ZO

NE

PA

RK

IN

G

ST

RE

TC

HE

R

T V

PA

TH

OL

OG

Y

LA

BO

RA

TO

RY

ME

DI

CI

NE

LA

B(

PA

TH

OL

OG

Y)

PA

RK

IN

G

ST

RE

TC

HE

R

RO

OF

RO

OF

RO

OF

RO

OF

RO

OF

AL

CO

VE

A

AL

CO

VE

A

ME

NS

TO

ILE

T

WO

ME

NS

TO

ILE

T

ST

OR

AG

E

A

FA

C

A

EL

EC

TR

IC

AL

E1

CL

OS

ET

A

SU

PP

LY

CL

OS

ET

CO

MM

UN

IC

AT

IO

N

RM

T1

LIN

EN

CH

UT

E

L1

CO

MM

UN

IC

AT

IO

N RM

T1 A

AL

CO

VE

A

ST

OR

AG

E

D

AL

CO

VE

A

CO

RR

ID

OR

C4

CO

RR

ID

OR

C4

IC

U

PA

T

ISO

LA

TIO

N

RM 46

CO

NN

EC

TIN

G

CO

RR

ID

OR

C4

NU

RS

E

ST

AT

IO

N

NU

RS

E

ST

AT

IO

N

CO

RR

ID

OR

C4

CO

RR

ID

OR

C4

CO

RR

ID

OR

C4

CO

RR

ID

OR

C4

EL

EV

AT

OR

LO

BB

Y C4

CO

RR

ID

OR

C4

CO

RR

ID

OR

C4

AL

CO

VE

EQ

UI

P

PA

RK

IN

G

A

CO

RR

ID

OR

C4

CO

RR

ID

OR

C4

CO

RR

ID

OR

C4

NU

RS

E

ST

AT

IO

N

NU

RS

E

ST

AT

IO

N

NU

RS

E

ST

AT

IO

N

NU

RS

E S

TA

TIO

N

EL

EC

TR

IC

AL

RM 46

E3

VIS

ITO

R

WA

ITI

NG

TO

ILE

T

A

TO

ILE

T

B

TO

ILE

T

A

ST

AIR

NO

EL

EV

AT

OR

P-

EL

EV

AT

OR

P-

TO

ILE

T

A

EM

PL

OY

EE

FIT

NE

SS

TO

ILE

T

A

RE

HA

B

EX

AM

R

M

RE

HA

B

EX

AM

R

M

TO

ILE

T

A

TO

ILE

T

A

RE

HA

B

EX

AM

R

M

LA

CT

AT

IO

N

RM 46

SO

CI

AL

WO

RK

ER

TO

ILE

T

A

TO

ILE

T

A

SO

CI

AL

WO

RK

ER

DO

CT

OR

OF

FIC

E

TO

ILE

T

A

TO

ILE

T

A

SIM

UL

AT

IO

N

RM 46

TO

ILE

T

A

SIM

UL

AT

IO

N

RM 46

TO

ILE

T

A

ON

-C

AL

L

EL

EV

AT

OR

P-

EL

EV

AT

OR

P-

EL

EV

AT

OR

P-

CO

NF

ER

EN

CE

R

M

PH

YS

VI

EW

IN

G

OF

FIC

E 3

OF

FIC

E 2

TO

ILE

T

A

ST

AF

F

LO

CK

ER

B

RE

SP

TH

ER

AP

Y

ST

OR

AG

E

A

ST

AF

F

LO

UN

GE

TE

AM

-5

RM 46

EM

S

H2

TE

AM

-4

RM 46

TE

AM RM 46

TO

ILE

T

A

ON

-C

AL

L

TO

ILE

T

A

TE

AM

R M

UI

C

TE

AM

R M

VA

SC

UL

AR

TO

ILE

T

A

ON

-C

AL

L

TE

AM

R M

SO

ILE

D

UT

ILI

TY

NO

UR

ISH

TO

ILE

T

A

ST

AIR

NO

ST

AF

F

LO

UN

GE

ST

AF

F

LO

CK

ER

BSO

CI

AL

W

OR

KE

R

15SO

CI

AL

WO

RK

ER

TE

AM

R M

EL

EC

TR

IC

AL

R

M

E1

TE

AM RM 46

EQ

UI

P

ST

OR

AG

E

CL

EA

N

LIN

EN

HA

C

H1

AD

PA

C

SO

CI

AL

WO

RK

ER

SIM

UL

AT

IO

N

RM 46

TO

ILE

T

A

SIM

UL

AT

IO

N

RM 46

SIM

UL

AT

IO

N

RM 46

TO

ILE

T

A

TO

ILE

T

A

DI

AL

YS

IS

TR

EA

TM

EN

T

RE

CY

CL

IN

G

TO

ILE

T

C

LO

UN

GE

B

EQ

UI

P

A

SP

H

SP

H

TO

ILE

T

A

TO

ILE

T

A

SP

H

DI

SC

HA

RG

E

LO

UN

GE

TO

ILE

T

A

TO

ILE

T

A

SO

CI

AL

W

OR

KE

R

36 OF

FIC

E

TO

ILE

T

A

TO

ILE

T

A

SIM

UL

AT

IO

N

RM

SIM

UL

AT

IO

N

RM

TO

ILE

T

A

IC

U

FA

MI

LY

W

AIT

IN

G

IC

U

PA

T

ISO

LA

TIO

N

RM 46

98TO

ILE

T

B

AN

TE

R

M

A

IC

U

PA

T R

M

IC

U

PA

T R

M

IC

U

PA

T R

M

IC

U

PA

T R

M

IC

U

PA

T R

M

IC

U

PA

T R

M

IC

U

PA

T R

M

EQ

UI

P S

TO

RA

GE

ST

AIR

NO

TO

ILE

T

EL

EC

TR

IC

AL

R

M

E2

EQ

UI

P

ST

OR

AG

E

CL

EA

N

LIN

EN

HA

C

H3

BR

EA

K R M

CL

EA

N

SU

PP

LY

SO

ILE

D

UT

ILI

TY

OF

FIC

E 4

CO

NS

UL

TA

TIO

N

CO

NS

UL

T

IC

U

PA

T R

M

IC

U

PA

T R

M

IC

U

PA

T R

M

IC

U

PA

T R

M

IC

U

PA

T R

M

IC

U

PA

T R

M

IC

U

PA

T R

M

IC

U

PA

T R

M

OF

FIC

E 1

IC

U

PA

T R

M

IC

U

PA

T R

M

IC

U

PA

T R

M

CO

RR

ID

OR

C4

CO

RR

ID

OR

C4

LA

B M 45

SU

PP

LY

BL

OO

D

DR

AW

AR

EA

TE

L

T1

EL

EC

TR

IC

AL

E2

ST

AIR NO

ME

NS

LO

CK

ER

CO

NF

ER

EN

CE

R

M

LO

UN

GE

ST

OR

AG

E

WA

LK

IN

RE

FR

ST

OR

AG

E

LE

AD

PA

TH

OL

OG

IST

PA

TH

AN

D

LA

B

ME

DI

CI

NE

O

FF

IC

E

HA

C

FR

OZ

EN

SE

CT

IO

N

AC

CE

SS

IO

NI

NG

LA

B

LA

B

LA

B

LA

B

GY

TO

LO

GY

WO

ME

NS

LO

CK

ER

TO

ILE

T

WO

ME

NS

LO

UN

GE

SU

PV

OF

FIC

E

BIM

O

FF

IC

E

TO

ILE

T

PL

MS

SE

CY

OF

FIC

E

PA

TH

OL

OG

IST

OF

FIC

E

UI

C

PA

TH

OL

OG

IST

S

AN

D

DI

RE

CT

OR

O F

OP

ER

AT

IO

NS

OF

FIC

E

CL

EA

N

SU

PP

LIE

S

A

CO

MP

RE

SS

OR

RM 45

CO

RR

ID

OR

C4

4A

A

WA

LK

IN

RE

FR

A

EL

EV

AT

OR

P-

A

RE

SID

EN

TS

OF

FIC

E

A

LC

H E

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SYMBOLS LIST

HORIZONTAL EXIT PASSAGEWAY

EXIT

EXIT PASSAGEWAY

INDIANAPOLIS, IN 46224

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

SUITE DESIGNATION

PO

LK

S

TR

EE

T

DAMEN AVENUE

TA

YL

O R

S

TR

EE

T

11B

1B

1A

EXIT SIGN

EMERGENCY LIGHT

FIRE ALARM PULL STATION

FIRE ALARM CONTROL PANEL

POSITIVE PRESSURE ROOM 15%

NEGATIVE PRESSURE ROOM 15%

POSITIVE PRESSURE ROOM 30%

NEGATIVE PRESSURE ROOM 30%

PARTIAL FOURTH FLOOR PLAN

8.15.10.3 OF NFPA 13 2013 EDITION.

EXIT PASSAGEWAY PER SECTION 7.2.6 OF NFPA 101-2012

EDITION. UTILITIES INSTALLED ABOVE SUSPENDED

CEILING PRIOR TO THE CURRENT REQUIREMENTS NOW

FOUND IN SECTION 7.1.3.2.1(10) OF NFPA 101-2012 EDITION

AND FIRST ADOPTED IN THE 1985 EDITION.

ELECTRICAL UTILITY INSTALLED IN STAIRWAY PRIOR TO

THE CURRENT REQUIREMENTS NOW FOUND IN SECTION

7.1.3.2.1(10) OF NFPA 101-2012 EDITION AND FIRST

ADOPTED IN THE 1985 EDITION.

NOT AN EXIT. CIRCULATION STAIR ONLY.

FIRE RATED GLASS WALL-60 MINUTE RATED.

LOCKED FOR CLINICAL NEEDS OF THE PATIENTS PER

SECTION 19.2.2.2.5.1 OF NFPA 101-2012.

SINGLE EXIT ROOM. MAXIMUM 49 OCCUPANTS.

CONTINUOUS HINGE COVERING DOOR RATING PLATE.

FIRE ESCAPE LADDER PER SECTION 7.2.9 OF NFPA

101-2012 EDITION.

FIRE SPRINKLERS INSTALLED PER LIBRARY AND SHELVING

STORAGE SPACING REQUIREMENTS OF SECTION 8.5.10 OF

NFPA 13-2013 EDITION.

POWER OPERATED DOORS RELEASE UPON FIRE ALARM

SIGNAL.

ALTERNATING TREAD STAIR PER SECTION 7.2.11 OF NFPA

101-2012 EDITION.

FOAM ACOUSTICAL PANELS INSTALLED ON THE CEILINGS

HAVE A CLASS A SMOKE SPREAD AND SMOKE DENSITY

RATING ( SEE TECHNICAL DATA SHEET IN SOC BINDER)

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .