537-16-102A Construction Plans IFC 08302020 - 1.pdf

PDF 12 MB Posted

Attached to
Z1DA--537-16-102A Corrections to Sprinkler System
Solicitation number
36C25222B0007
Issued by

About this file

This document provides details on a federal contract solicitation from the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 12. Solicitation number 36C25222B0007 seeks corrections to a sprinkler system at Project 537-16-102A. The opportunity type is listed as a solicitation. The description indicates the solicitation is for corrections to the sprinkler system at the specified project location, with no other details provided.

View the file

Other files

File Type Posted
S06 - 537-16-102A Construction Plans IFC - Photos - 4.pdf PDF
36C25222B0007 0013.docx DOCX document
36C25222B0007 0012.docx DOCX document
S06 - 537-16-102A Construction Plans IFC - Photos - 6.pdf PDF
S06 - 537-16-102A Construction Plans IFC - Photos - 5.pdf PDF
S06 - 537-16-102A Construction Plans IFC - Photos - 7.pdf PDF
S06 - 537-16-102A Construction Plans IFC - Photos - 2.pdf PDF
S06 - 537-16-102A Construction Plans IFC - Photos - 1.pdf PDF
36C25222B0007 0011.docx DOCX document
S06 - 537-16-102A Construction Plans IFC - Photos - 4.pdf PDF
S06 - 537-16-102A Construction Plans IFC - Photos - 3.pdf PDF
S06 - 537-16-102A Construction Plans Issued for Bid and Construction 02_11_2022 - (1).pdf PDF
S06 - 537-16-102A Construction Plans Issued for Bid and Construction 02_11_2022 - (2).pdf PDF
S06 - VA Responses to RFIs.pdf PDF
S06 - Wage Determination 01_14_2022.pdf PDF
36C25222B0007 0010.docx DOCX document
S06 - 537-16-102A Specifications Issued for Bid and Construction 02_03_2022.pdf PDF
36C25222B0007 0009.docx DOCX document
36C25222B0007 0008.docx DOCX document
36C25222B0007 0007.docx DOCX document
S06 - Campus Floor Plan 1 of 2.pdf PDF
S06 - Pre-Bid Site Visit Attendance Sheet - 1-14-22.pdf PDF
S06 - Record Drawings 1 of 8.pdf PDF
S06 - Pre-Bid Site Visit Attendance Sheet - 1-5-22.pdf PDF
36C25222B0007 0006.docx DOCX document
S06 - Attachments 0006.zip ZIP file
36C25222B0007 0005.docx DOCX document
537-16-102A Construction Plans IFC 08302020-2.pdf PDF
537-16-102A Construction Plans IFC 08302020 - 2.pdf PDF
36C25222B0007 0004.docx DOCX document
S06 - Record Drawings 4 of 8.pdf PDF
36C25222B0007 0003.docx DOCX document
S06 - Record Drawings 8 of 8.pdf PDF
S06 - Record Drawings 5 of 8.pdf PDF
S06 - Record Drawings 7 of 8.pdf PDF
S06 - Record Drawings 6 of 8.pdf PDF
S06 - Attachments 0002.zip ZIP file
36C25222B0007 0002.docx DOCX document
36C25222B0007 0001.docx DOCX document
S06 - Attachments 0001.zip ZIP file
S02 - 537-16-102A Specifications IFC 02082020.pdf PDF
S02 - 537-16-102A Construction Plans IFC 08302020.pdf PDF
S02 - VHA Sup Con Req for Combatting COVID-19.pdf PDF
S02 - Statement of Work.pdf PDF
S02 - Wage Determination as of 12_3_21.pdf PDF
36C25222B0007.docx DOCX document
Show all 46

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REFER

KEYNOTE

EQUIPMENT TAG

GENERAL SYMBOLS

ELEVATION SYMBOL

DETAIL REFERENCE (TOP=DETAIL NUMBER,

BOTTOM=DRAWING NUMBER)

PLAN CONTINUATION REFERENCE

(BOTTOM=DRAWING NUMBER)

SECTION DESIGNATION (TOP=SECTION

NUMBER, BOTTOM=DRAWING NUMBER)

POINT OF NEW CONNECTION TO EXISTING

WHEN ON DEMO SHEET: END POINT OF DEMO

X0.0

FEC

FLOW SWITCH

FVC

FHC

DRY PIPE VALVE ASSEMBLY

PREACTION VALVE ASSEMBLY

SPRINKLER ZONE CONTROL

FIRE ALARM BELL

VALVE ASSEMBLY

FPTH

FDC

FDV

FIRE PROTECTION SYMBOLS

B

FIRE DEPARTMENT CONNECTION

FIRE PUMP TEST HEADER

FIRE DEPARTMENT VALVE

ROOF TOP TEST HEADER

FIRE HOSE CABINET

FIRE VALVE CABINET

FIRE EXTINGUISHER (WALL HUNG)

FIRE EXTINGUISHER CABINET

PUMP

FIRE PROTECTION ANNOTATION

FIRE SUPPLY

SPRINKLER PIPE

DRY SPRINKLER PIPE

SPR

DSPR

F

CLEAN AGENTCLA

DIAMETERDIA

ACCESS PANELAP

AFF ABOVE FINISHED FLOOR

ADJ ADJUSTABLE

CLG

CL

CEILING

CENTERLINE

MINIMUM

PRESSURE REDUCING VALVE

RPBP

SCH

RPM

REDUCED PRESSURE ZONE

SCHEDULE

REVOLUTIONS PER MINUTE

PSIG

PSI

NTS

OD

OC

NPT

MTG

MTD

POUNDS PER SQUARE INCH GAUGE

POUNDS PER SQUARE INCH

ON CENTER

NATIONAL PIPE THREAD

NOT TO SCALE

OUTSIDE DIAMETER

TYP

PRV

TYPICAL

MOUNTING

MOUNTED

MIN

SPR SPRINKLER

V VALVE

GALLONS PER MINUTE

FIRE PUMP TEST HEADER

INSIDE DIAMETER

IN

ID

GPM

GA

GAL

FPTH

INCHES

GAUGE

GALLON

FHC FIRE HOSE CABINET

ELEV ELEVATION

MAX MAXIMUM

POUNDS PER SQUARE FOOTPSF

FLOORFLR

FIRE VALVE CABINETFVC

BOTTOM OF PIPEBOP

IE INVERT ELEVATION

FDC FIRE DEPARTMENT CONNECTION

FLOW SWITCHFS

FDV FIRE DEPARTMENT VALVE

FIRE PUMP CONTROLLERFPC

DSP DRY SPRINKLER PIPE

HUB DRAINHD

JPC

JP

JOCKEY PUMP CONTROLLER

JOCKEY PUMP

F FIRE SUPPLY

FACP FIRE ALARM CONTROL PANEL

VESDA VERY EARLY SMOKE DETECTION APPARATUS

AIR COMPRESSORAC

ACC ACCESS

RV RELIEF VALVE

BACKFLOW PREVENTER

EX EXISTING

GALV

GALVANIZED

DOUBLE DETECTOR CHECK ASSEMBLYDDCA

ABBREVIATIONS

CSP COMBINED SPRINKLER STANDPIPE RISER

SP STAND PIPE

SD SPRINKLER DRAIN

DRY PIPEDP

1. THE CONTRACTORS WORK SHALL CONFORM TO THE

OWNERS POLICIES ON CONSTRUCTION PROCEDURES.

2. COORDINATE WITH THE OWNER FOR ANY EQUIPMENT

REMOVED THAT NEEDS TO BE RETURNED TO THE OWNER.

3. COORDINATE WITH OWNER FOR ANY TEMPORARY SYSTEM

SHUTDOWNS NECESSARY TO COMPLETE THE WORK.

4. PATCH PIPING RISERS AS REQUIRED.

5. COORDINATE WITH OWNER FOR ANY FLOOR CORING

WORK THAT IS REQUIRED.

6. ANY MODIFIED OR ADDED SPRINKLERS SHALL BE PIPED

USING THE INSTALLED BUILDING PIPE SCHEDULE SINCE

THIS HAS BEEN HYDRAULICALLY CALCULATED.

GENERAL FIRE PROTECTION NOTES

1. THE FIRE PROTECTION DEMOLITION DRAWINGS SHOW

EXISTING PIPING, EQUIPMENT AND DEVICES WHICH ARE

INTENDED TO BE REMOVED. THESE DRAWINGS INDICATE THE

REQUIRED SCOPE OF WORK AND ARE NOT INTENDED TO

REFER TO EVERY PIECE OF EQUIPMENT OR PIPE THAT MUST

BE REMOVED IN ORDER TO COMPLETE THE WORK. IT SHALL

BE THE CONTRACTOR'S RESPONSIBILITY TO VISIT THE SITE

AND VERIFY THE CURRENT INSTALLATION BEFORE

SUBMITTING A BID FOR THE WORK.

2. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY

THE CONDITION OF ALL EXISTING EQUIPMENT. EXACT SIZES

OF EXISTING PIPING, ETC. BEFORE DEMOLITION WORK IS

BEGUN. REPORT ANY DISCREPANCIES BETWEEN PLANS AND

ACTUAL FIELD CONDITIONS TO ARCHITECT AND ENGINEER

PRIOR TO THE COMMENCEMENT OF DEMOLITION WORK.

3. WHERE DEMOLITION WORK WILL INTERRUPT FIRE

PROTECTION SERVICE TO AREAS OF THE FACILITY THAT ARE

TO REMAIN IN OPERATION, COORDINATE ANY INTERRUPTIONS

WITH THE OWNER AT LEAST TWO WEEKS PRIOR AND

ACCOMMODATE THE OWNER'S NEEDS ARE REQUIRED.

4. REMOVE THE INDICATED FIRE PROTECTION ITEMS AS SHOWN

ON PLANS. THIS INCLUDES ALL HANGERS, STRAPS, AND

RELATED MATERIAL.

5. THE FIRE PROTECTION CONTRACTOR SHALL BE

RESPONSIBLE FOR CUTTING AND PATCHING OF EXISTING

CONSTRUCTION UNLESS OTHERWISE NOTED ON PLANS. NO

CUTTING OF STRUCTURAL MEMBERS OR STRUCTURE WHICH

WILL DETERIORATE THE INTEGRITY AND STRENGTH OF THE

BUILDING WILL BE ALLOWED WITHOUT THE WRITTEN

APPROVAL FROM THE STRUCTURAL ENGINEER.

6. PATCH AND REPAIR OPENINGS THROUGH WALLS AND

FLOORS WHERE PIPES WERE REMOVED TO MATCH EXISTING

AND TO MAINTAIN FIRE RATINGS.

7. CONTRACTOR SHALL VERIFY CLEARANCE REQUIREMENTS

AND INDICATE ROUTING OF NEW PIPING BEFORE

FABRICATION BEGINS AS RISES AND DROPS MAY BE

NECESSARY DUE TO EXISTING FIELD CONDITIONS.

GENERAL FIRE PROTECTION

DEMOLITION NOTES

2 HOUR FIRE/SMOKE RESISTANCE RATING

1 HOUR FIRE/SMOKE RESISTANCE RATING

2 HOUR FIRE RESISTANCE RATING

30 MINUTE SMOKE BARRIER

1 HOUR FIRE RESISTANCE RATING

SMOKE RESISTIVE HAZARDOUS ENCLOSURE

SMOKE AND FIRE WALL LEGEND

1S

REMARKSESCUT SIN #K FINISHTHREADMFG. TEMPMODEL

SPRINKLER LEGEND

TYPESYM. RESP

UPRIGHT R1425RELIABLE 155°Q.R. F1FR-56 --------BRASS5.61/2"

SIDEWALL R1435RELIABLE 155°Q.R. F1FR-56 --------BRASS5.61/2"

PENDENT R1414RELIABLE 155°Q.R. F1FR-56 SEMI-RECESSEDCHROME5.61/2"

DRY PENDENT R5714RELIABLE 155°Q.R. F3QR56 TWO-PIECECHROME5.61/2"

UPRIGHT R1325RELIABLE 155°S.R. F1-56 --------BRASS5.61/2"

S A

N

S T

O R

M

820 S. DAMEN AVENUE

CHICAGO, ILLINOIS 60612

312.569.8387

PROJECT LOCATION:

JESSE BROWN VA MEDICAL CENTER

PROJECT TITLE:

SPRINKLER CORRECTIONS

[MATOC] 537-16-102A

BUILDING NUMBERS:

01, 11, 30, 40, & 42

V U.S. Department of Veterans Affairs A

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions

31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins

Sprinkler Corrections

Jesse Brown VAMC

Chicago, IL

537-16-102A

Project Director

Revisions: Date:

Keyplan: Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions

31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins

Sprinkler Corrections

Jesse Brown VAMC

Chicago, IL

537-16-102A

Project Director

Revisions: Date:

Keyplan:

FP001

NOTES, SYMBOLS, AND

ABBREVIATIONS

08/30/2020

100% Complete and Final

Issued for 100% Complete and Final

Issued for 100% CD

08/30/2020

02/10/2020

B400

B440

CRAWL SPACE

OPEN TO

CROSS PIPE

UP

DN

STAIR

UP

UP

LOUVER

WINDOW

LOUVER

WINDOW

LOUVER

WINDOW

LOUVER

WINDOW

LOUVER

WINDOW

LOUVER

WINDOW

LOUVER

WINDOW

LOUVER

WINDOW

LOUVER

WINDOW

LOUVER

WINDOW

LOUVER

WINDOW

LOUVER

WINDOW

LOUVER

WINDOW

LOUVER

WINDOW

LOUVER

WINDOW

LOUVER

WINDOW

LOUVER

WINDOW

LOUVER

WINDOW

STAIR

UP

NO 5NO 2

LOUVER

WINDOW

LOUVER

WINDOW

LOUVER

WINDOW

DN

SVC

LOBBY

CB-1

CORRIDOR

CB-2

ELEVATOR

B409

B443

B441

MECH RM

MULTIPURPOSE RM

B456

SUPPLY RM

B452

EMS STORAGE

B451

ELEVATOR

PIT

P1

ELEVATOR

PIT

P2

ELEVATOR

PIT

P3

ELEVATOR

PIT

P4

ELEVATOR

S5

ELEVATOR

S6ELECTRICAL

STORAGE

B402

STAIR

NO 1

B401

B403

MECH/TANK RM

ELECTRICAL STORAGE

BACK FILL

BACK FILL

ELEVATOR

NO P7

2 2

B400

B440

CRAWL SPACE

OPEN TO

CROSS PIPE

UP

DN

STAIR

UP

UP

STAIR

UP

NO 5NO 2

DN

TS

TS

B01B

B01A NORTH

B

A

S

O U

T H

B

N

R

T H

B

U

T H

B

R

T H

B01B

B01A NORTH

N TS

UP

DN

UP

UP

UP

DN

R TS

R

TS

B01B

B01A NORTH

B

U

T H

B

R

T H

B

U

T H

B

R

T H

B01B

B01A NORTH

D0

A1

D0

A2

D0

A3

D0

A5

D0

A6

D0

A7

D0

A8

D0

A9

D0

B1

D0

B2

D0

B3

D0

A6

D0

B1

D0

B3

D0

B3

B01A FX100-N

BUILDING 01A

BASEMENT PLAN NORTH

08/30/2020

100% Complete and Final

Issued for 100% Complete and Final

Issued for 100% CD

08/30/2020

02/10/2020

B01

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions

31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins

Sprinkler Corrections

Jesse Brown VAMC

Chicago, IL

537-16-102A

Project Director

Revisions: Date:

1/8"=1'-0"

4' 8'0 16'

Keyplan:

N

S

FIRE PROTECTION KEYED NOTES:

**THE NOTES PROVIDED HERE CORRESPOND TO THE ASSOCIATED PHOTOS

GENERATED IN THE FIELD REPORT FOR THIS AREA. REFER TO PHOTOS FOR

OBSERVED DEFICIENCIES, DEFECTS, OMISSIONS, AND ERRORS OF THE

EXISTING SPRINKLER SYSTEM. 10-02-2019 BUILDING 1 LOWER LEVEL.

INCOMING FIRE SERVICE MAIN ELBOW SHALL BE REPLACED. (PHOTO 1)

REMOVE ZIP TIE BETWEEN SPRINKLER PIPE AND CONDUIT. PROVIDE

PROPER HANGER FOR INSTALLATION SUPPORT. (PHOTO 2)

EXISTING VALVES ON WATER SERVICE ARE RUSTED AND SHALL BE

REPLACED. PROVIDE NEW OS&Y VALVES AND RECONNECT TAMPER

SWITCHES. (PHOTO 3)

REPLACE ALL PIPING IN BASEMENT LEVEL MECHANICAL TANK ROOM

WITHIN BUBBLED AREA. CURRENT STEAM LEAK HAS CORRODED PIPING

AND FITTINGS TO DISREPAIR. PIPING AND FITTINGS ARE RUSTING AND

CONTINUAL CORROSION WILL LEAD TO FAILURE OF PIPING. REPLACE

EXISTING HEADS WITHIN BUBBLED AREA WITH INTERMEDIATE

TEMPERATURE HEADS WITH 212°F RATING. (PHOTOS 4 - 17, 23, & 24)

EXISTING PIPE PENETRATION THROUGH FIREWALL SHALL HAVE FIRE

SEALANT INSTALLED IN OPENING. (PHOTO 18)

PAINT PIPING TO ELEVATOR PIT SPRINKLERS RED TO MATCH ALL

SURROUNDING MECHANICAL ROOM PIPING. (PHOTOS 19, & 22)

REVISE PIPING IN CORRIDOR TO ELIMINATE CONFLICTS WITH OTHER TRADE

PIPING/CONDUIT. CURRENTLY A PIECE OF WOOD BEING USED TO

SEPARATE ITEMS. (PHOTO 20)

EXISTING VALVE IN CORRIDOR HAS NON-RISING STEM, DOESN'T HAVE LOCK

TO PREVENT CLOSING, DOESN'T HAVE TAMPER SWITCH OR ANY

SUPERVISORY DEVICE. INSTALL LOCK ON VALVE TO SECURE VALVE TO

PREVENT CLOSURE. LOCK SHALL MEET NFPA REQUIREMENTS (PHOTO 21)

EXISTING FIRE PUMP CONCRETE PAD, 30" X 72" X 10" TO BE DEMOLISHED.

RESURFACE REMAINING CONCRETE TO MATCH SURROUNDING AREA.

SPRINKLER HEAD MISSING FROM DOCUMENTS, ADDED FOR ACCURACY OF

PLANS.

PROVIDE ADDITIONAL SPRINKLER HEAD UNDERNEATH BASE OF STAIRS.

PROVIDE CONNECTION FROM BRANCHLINE SERVING HEADS IN STAIRWELL

CORRIDOR.

EXISTING 6" BUTTERFLY VALVE WITH TAMPER SWITCH TO FEED RISERS TO

REMAIN.

D0

A1

D0

A2

D0

A3

D0

A4

D0

A5

D0

A6

D0

A7

D0

A8

D0

A9

D0

B1

D0

B2

D0

B3

STAIR

UP

LOUVER

WINDOW

LOUVER

WINDOW

LOUVER

WINDOW

LOUVER

WINDOW

LOUVER

WINDOW

NO 2

STAIR

UP

NO 2

TS

F

L

F

L

F

L

B

U

T H

B

R

T H

B

U

T H

B

R

T H

N TS

UP

R

TS

F

L

F

L

F

L

F

L

F

L

F

L

B

U

T H

B

R

T H

B

U

T H

B

R

T H

D0

B3

D0

B3

B01A FX100-S

BUILDING 01A

BASEMENT PLAN SOUTH

08/30/2020

100% Complete and Final

Issued for 100% Complete and Final

Issued for 100% CD

08/30/2020

02/10/2020

B01

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions

31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins

Sprinkler Corrections

Jesse Brown VAMC

Chicago, IL

537-16-102A

Project Director

Revisions: Date:

1/8"=1'-0"

4' 8'0 16'

Keyplan:

N

S

FIRE PROTECTION KEYED NOTES:

**THE NOTES PROVIDED HERE CORRESPOND TO THE ASSOCIATED PHOTOS

GENERATED IN THE FIELD REPORT FOR THIS AREA. REFER TO PHOTOS FOR

OBSERVED DEFICIENCIES, DEFECTS, OMISSIONS, AND ERRORS OF THE

EXISTING SPRINKLER SYSTEM. 10-02-2019 BUILDING 1 LOWER LEVEL.

INCOMING FIRE SERVICE MAIN ELBOW SHALL BE REPLACED. (PHOTO 1)

REMOVE ZIP TIE BETWEEN SPRINKLER PIPE AND CONDUIT. PROVIDE

PROPER HANGER FOR INSTALLATION SUPPORT. (PHOTO 2)

EXISTING VALVES ON WATER SERVICE ARE RUSTED AND SHALL BE

REPLACED. PROVIDE NEW OS&Y VALVES AND RECONNECT TAMPER

SWITCHES. (PHOTO 3)

REPLACE ALL PIPING IN BASEMENT LEVEL MECHANICAL TANK ROOM

WITHIN BUBBLED AREA. CURRENT STEAM LEAK HAS CORRODED PIPING

AND FITTINGS TO DISREPAIR. PIPING AND FITTINGS ARE RUSTING AND

CONTINUAL CORROSION WILL LEAD TO FAILURE OF PIPING. (PHOTOS 4 - 17,

23, & 24)

EXISTING PIPE PENETRATION THROUGH FIREWALL SHALL HAVE FIRE

SEALANT INSTALLED IN OPENING. (PHOTO 18)

PAINT PIPING TO ELEVATOR PIT SPRINKLERS RED TO MATCH ALL

SURROUNDING MECHANICAL ROOM PIPING. (PHOTOS 19, & 22)

REVISE PIPING IN CORRIDOR TO ELIMINATE CONFLICTS WITH OTHER TRADE

PIPING/CONDUIT. CURRENTLY A PIECE OF WOOD BEING USED TO

SEPARATE ITEMS. (PHOTO 20)

EXISTING VALVE IN CORRIDOR HAS NON-RISING STEM, DOES NOT HAVE

LOCK TO PREVENT CLOSING, DOES NOT HAVE TAMPER SWITCH OR ANY

SUPERVISORY DEVICE. VALVE SHALL HAVE LOCK TO PREVENT CLOSURE.

(PHOTO 21)

EXISTING FIRE PUMP CONCRETE PAD, 30" x 72" x 10" TO BE DEMOLISHED.

RESURFACE REMAINING CONCRETE TO MATCH SURROUNDING AREA.

SPRINKLER HEAD MISSING FROM DOCUMENTS, ADDED FOR ACCURACY OF

PLANS.

PROVIDE ADDITIONAL SPRINKLER HEAD UNDERNEATH BASE OF STAIRS.

PROVIDE CONNECTION FROM BRANCHLINE SERVING HEADS IN STAIRWELL

CORRIDOR.

EXISTING 6" BUTTERFLY VALVE WITH TAMPER SWITCH TO FEED RISERS TO

REMAIN.

D0

A1

D0

A2

D0

A3

D0

A4

D0

A5

D0

A6

D0

A7

D0

A8

D0

A9

D0

B1

D0

B2

OVER HEAD DOOR

FIRE

CLOSET

RADIOLOGY

SCHEDULING

TOILET

1491A

ON CALL

1491B

STAIR

EMS LINEN RM

ELEVATOR

MECH

ELEVATOR

FOYER

MORGUE

ELEVATOR

STAIR

NO 5 TELECOMMUNICATION RM

14T4

ELECTRICAL

14E7

TOILET

1499A

DOCTOR

OFFICE

SECRET

OFFICE

STORAGE

COMP AND

PENS STAFF

GAS CYLINDER

STORAGE

VESTIBULE

1499B

NO 5A 1

4.1

3.8

NEW

COLUMN

LINE

1.1

B01B

B01A NORTH

D1

B2

D1

B3

D1

B4

D1

B5

1S

S

S

S

S

S

D1

A3

D1

A3

D1

B6

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions

31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins

Sprinkler Corrections

Jesse Brown VAMC

Chicago, IL

537-16-102A

Project Director

Revisions: Date:

1/8"=1'-0"

4' 8'0 16'

Keyplan:

N

S B01A FX101-N

BUILDING 01A

FIRST FLOOR PLAN NORTH

08/30/2020

100% Complete and Final

Issued for 100% Complete and Final

Issued for 100% CD

08/30/2020

02/10/2020

B01

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions

31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins

Sprinkler Corrections

Jesse Brown VAMC

Chicago, IL

537-16-102A

Project Director

Revisions: Date:

1/8"=1'-0"

4' 8'0 16'

Keyplan:

N

S

BUILDING 1A 1ST FLOOR PLAN NORTH

1/8" = 1'-0"

FIRE PROTECTION KEYED NOTES:

**THE NOTES PROVIDED HERE CORRESPOND TO THE ASSOCIATED PHOTOS

GENERATED IN THE FIELD REPORT FOR THIS AREA. REFER TO PHOTOS FOR

OBSERVED DEFICIENCIES, DEFECTS, OMISSIONS, AND ERRORS OF THE EXISTING

SPRINKLER SYSTEM. 01-15-2020 & 01-17-2020 FULL CAMPUS 1ST FLOOR.

SPRINKLER HEAD INSTALLED TO FAR FROM BACK WALL, >9'-0". RELOCATE

SPRINKLER ONE TILE CLOSER TO WALL (2'-0") TO MEET CODE SPACING

REQUIREMENTS. (PHOTO 26)

SPRINKLER PIPING RUSTING - 4 - 6 FOOT LENGTH. REPLACE WITH NEW

(PHOTOS 33, 34 & 37)

SPRINKLER FITTING RUSTED. REPLACE WITH NEW.

(PHOTOS 35, 36, 44, 46, 47, 48, 55)

DRAIN PAN SUPPORTED BY SPRINKLER PIPING. PROVIDE SEPARATE

HANGER SYSTEM FOR DRAIN PAN SYSTEM (2 LINES) (PHOTO 38)

HANGER ROD BENT. REPLACE WITH NEW

(PHOTO 39)

SPRINKLER HEADS NOT PROVIDED UNDER DUCTWORK. INSTALL

SPRINKLER UNDER DUCTWORK (PHOTO 40)

SPRINKLER PROTECTION IN GARAGE NOT PROTECTED WITH DRY PIPE

VALVE. INSTALL NEW DRY PIPE VALVE. DRAIN SYSTEM AND RECONNECT

GARAGE SYSTEM TO DRY PIPE VALVE. (PHOTO 41)

SPRINKLER HEADS IN GARAGE ARE BLOCKED BY CEILING ELEVATION

CHANGE. REVISE SPRINKLER LAYOUT TO PROVIDE PROPER COVERAGE.

(PHOTO 42)

SPRINKLER COVERAGE IN GARAGE DOES NOT COVER UNDER ROLL UP

DOORS. PROVIDE SIDEWALL HEADS FOR PROTECTION UNDER DOORS.

ENSURE HEADS WILL NOT BE HIT BY AMBULANCE (PHOTO 43)

EXPOSED SPRINKLER PIPING IN TELECOM CLOSET CANNOT BE CPVC.

REPLACE PIPING WITH METAL. SPRINKLER HEAD NOT INSTALLED WITHIN 8"

OF DECK. INSTALL HEAD CLOSER TO DECK. (PHOTO 45)

SPRINKLER HEAD RUSTED AND SURROUNDING CEILING HAS WATER

DAMAGE. REPLACE HEAD. REPLACE SPRINKLER HEAD WITH NEW. REMOVE

ENTIRE DRYWALL CEILING IN ROOM AND REPLACE WITH NEW. REVIEW

WITH BUILDING ENGINEERING ABOVE CEILING SPACE. (PHOTO 49)

SIDEWALL HEAD ON EXTERIOR OBSTRUCTED BY DRAIN LINE. RELOCATE

HEAD OR ADD HEAD ON OTHER SIDE OF PIPE. (PHOTO 50)

LOWER STAIRWELL TO EXTERIOR AND CRAWLSPACE DOES NOT HAVE

SPRINKLER PROTECTION. INSTALL NEW HEAD UNDER LANDING. (PHOTO 54)

CRAWLSPACE ACCESS AND SPACE DOES NOT HAVE SPRINKLER

PROTECTION. PROVIDE SIGNAGE ON ACCESS DOOR. "SPACE FOR SUB

BASEMENT MAINTENANCE ACCESS ONLY. NOT TO BE USED FOR STORAGE.

ACCESS NOT PERMITTED WITHOUT AUTHORIZATION FROM ENGINEERING."

CLEAR OUT ALL ITEMS WITHIN BASEMENT. (PHOTOS 56, 57, & 58)

EXISTING 2 1/2" BUTTERFLY VALVE WITH TAMPER SWITCH TO FEED FLOOR

SPRINKLER ZONE TO REMAIN.

(PHOTOS 27-32, 51-53, & 59-62)

D1

A1

D1

A2

D1

A3

D1

A4

D1

A5

D1

A6

D1

A7

D1

A8

D1

A9

D1

B1

D1

B2

D1

B3

D1

B4

D1

B5

D1

B6

ROLLING SHUTTER ROLLING SHUTTER

OVER HEAD DOOR

FEC

PNEUMATIC

TUBE

FAC

FAC

TEL

FIRE

HOSE

11E1

ELEVATOR

NO S5

ELEVATOR

NO S6

ELEVATOR

NO P1

ELEVATOR

NO P2

CORRIDOR

C1404

TOILET

1491A

CORRIDOR

C1405

CORRIDOR

C1407

CORRIDOR

C1406

CORRIDOR

C1409

CORRIDOR

C1445

WAITING RM

WOMENS

TOILET

MENS TOILET

HEALTH VET

CO-ORDR

CREDIT

UNION

FIRE

CONTROL

PATIENT

ADVOCATE

OFFICE

OPTICAL

DISPENSARY

1410A

TRIAGE

TRIAGE

ELECTRICAL

SWITCH RM

14E2

TRIAGE

ED PHYSICIAN

1414ELECTRICAL

14E1

ADDICTION

CONSULT

RM

RECEPTION

CONSULT

RM

PATIENT

ADVOCATE

1459A

E D OFFICE

ELECTRICAL

14E3

DECENDENT

AFFAIRS

CONSULT

RM

HAC

TOILET

1446 TEL

14T1

VESTIBULE/STAIR

STAIR

NO 2

PAC

CO-ORDR

OFFICE

CHIEF

CONSULT

RM

CONSULT

RM

CONSULT

RM

EMS

HOUSE

KEEPING

ELEVATOR

NO P7

ELEVATOR

NO P8

TEL

CLOSET

14T2

14E4

STAIR

NO 1

ELEVATOR

NO P3

ELEVATOR

NO P4

NURSE STATION EMERGENCY RM

EQUIP STORAGE

LOUNGE

ELECTRICAL

14E6

COMM

14T3

BEREAVEMENT

RM

1475A

SOILED

UTILITY

EXAM RM-7

1470G

EXAM RM-6

1470F

EXAM RM-5

1470E

EXAM RM-4

1470D

EXAM RM-3

1470C

EXAM RM-2

1470B

E D MGR

CFD SUPPLY

EXAM RM-1

1470A

ER HALLWAY

TRAVEL PAY

STORAGE

RECEPTION AND

ADMISSION

AMBULATORY

CARE SUPV

OFFICE

CHIEF

AMBULATORY

CORRIDOR

C1411

MANAGER

EMS STORAGE

1431A

ER STORAGE

1431B

TRIAGE

E D ATTENDING

TRIAGE

MEDICAL

SUPPORT

SUPERV

1431C

VAM NURSE

MNGR.

TOILET

VESTIBULE

C1408

GARAGE

LIFT

EQUIP.

CLEAN

SUPPLY

CLEAN

LINEN

TOILET

NEGATIVE

PRESSURE

RM

EXAM RM-15

1470R

EXAM RM-14

1470Q

EXAM RM-13

1470P

EXAM RM-12

1470N

EXAM RM-11

1470M

PARAMEDIC RM

1470L

MEDS

1470H

EXAM RM-8

1470J

EXAM RM-9

1470K

ON CALL

1491B

STAIR

DONATED

CLOTHING

1508 EMS LINEN RM

PHARMACY IV

STORAGE

VESTIBULE

CORRIDOR

C1505

CORRIDOR

C1504

ENTRANCE/LOBBY

C1103

ELECTRICAL

1541B

CLEAN

SUPPLY

CORRIDOR

C1502

HAC

CORRIDOR

C1503

GAS CYLINDER

STORAGE

CORRIDOR

CORRIDOR

ELECTRICAL

CLOSET

OPTICAL

WAITING RM

CORRIDOR

C1505

NO 5A

1436A

NO 2

1410B

C1404

C1404

ELECTRIC

CLOSET

14E5

TOILET

B01B

B01A NORTH

B

U

T H

B

R

T H

B

U

T H

B

R

T H

B11B

B30

D1

A7

D1

A8

D1

B1

D1

B2

S

1S

2 2 2 2 2

2 2 2 2 2 2 2

S

S

1S

S

1S

S

1S

1S

S

S

S

S

S

1S

S

S

S

D1

A8

D1

A8

D1

A8

D1

A9

D1

A9

D1

A3

D1

A3

D1

A3

D1

A3

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions

31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins

Sprinkler Corrections

Jesse Brown VAMC

Chicago, IL

537-16-102A

Project Director

Revisions: Date:

1/8"=1'-0"

4' 8'0 16'

Keyplan:

N

S B01A FX101-S

BUILDING 01A

FIRST FLOOR PLAN SOUTH

08/30/2020

100% Complete and Final

Issued for 100% Complete and Final

Issued for 100% CD

08/30/2020

02/10/2020

B01

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions

31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins

Sprinkler Corrections

Jesse Brown VAMC

Chicago, IL

537-16-102A

Project Director

Revisions: Date:

1/8"=1'-0"

4' 8'0 16'

Keyplan:

N

S

BUILDING 1A 1ST FLOOR PLAN SOUTH

1/8" = 1'-0"

FIRE PROTECTION KEYED NOTES:

**THE NOTES PROVIDED HERE CORRESPOND TO THE ASSOCIATED PHOTOS

GENERATED IN THE FIELD REPORT FOR THIS AREA. REFER TO PHOTOS FOR

OBSERVED DEFICIENCIES, DEFECTS, OMISSIONS, AND ERRORS OF THE EXISTING

SPRINKLER SYSTEM. 01-15-2020 & 01-17-2020 FULL CAMPUS 1ST FLOOR.

SPRINKLER HEAD INSTALLED TO FAR FROM BACK WALL, >9'-0". RELOCATE

SPRINKLER ONE TILE CLOSER TO WALL (2'-0") TO MEET CODE SPACING

REQUIREMENTS. (PHOTO 26)

SPRINKLER PIPING RUSTING - 4 - 6 FOOT LENGTH. REPLACE WITH NEW

(PHOTOS 33, 34 & 37)

SPRINKLER FITTING RUSTED. REPLACE WITH NEW.

(PHOTOS 35, 36, 44, 46, 47, 48, 55)

DRAIN PAN SUPPORTED BY SPRINKLER PIPING. PROVIDE SEPARATE

HANGER SYSTEM FOR DRAIN PAN SYSTEM (2 LINES) (PHOTO 38)

HANGER ROD BENT. REPLACE WITH NEW

(PHOTO 39)

SPRINKLER HEADS NOT PROVIDED UNDER DUCTWORK. INSTALL

SPRINKLER UNDER DUCTWORK (PHOTO 40)

SPRINKLER PROTECTION IN GARAGE NOT PROTECTED WITH DRY PIPE

VALVE. INSTALL NEW DRY PIPE VALVE. DRAIN SYSTEM AND RECONNECT

GARAGE SYSTEM TO DRY PIPE VALVE. (PHOTO 41)

SPRINKLER HEADS IN GARAGE ARE BLOCKED BY CEILING ELEVATION

CHANGE. REVISE SPRINKLER LAYOUT TO PROVIDE PROPER COVERAGE.

(PHOTO 42)

SPRINKLER COVERAGE IN GARAGE DOES NOT COVER UNDER ROLL UP

DOORS. PROVIDE SIDEWALL HEADS FOR PROTECTION UNDER DOORS.

ENSURE HEADS WILL NOT BE HIT BY AMBULANCE (PHOTO 43)

EXPOSED SPRINKLER PIPING IN TELECOM CLOSET CANNOT BE CPVC.

REPLACE PIPING WITH METAL. SPRINKLER HEAD NOT INSTALLED WITHIN 8"

OF DECK. INSTALL HEAD CLOSER TO DECK. (PHOTO 45)

SPRINKLER HEAD RUSTED AND SURROUNDING CEILING HAS WATER

DAMAGE. REPLACE HEAD. REPLACE SPRINKLER HEAD WITH NEW. REMOVE

ENTIRE DRYWALL CEILING IN ROOM AND REPLACE WITH NEW. REVIEW

WITH BUILDING ENGINEERING ABOVE CEILING SPACE. (PHOTO 49)

SIDEWALL HEAD ON EXTERIOR OBSTRUCTED BY DRAIN LINE. RELOCATE

HEAD OR ADD HEAD ON OTHER SIDE OF PIPE. (PHOTO 50)

LOWER STAIRWELL TO EXTERIOR AND CRAWLSPACE DOES NOT HAVE

SPRINKLER PROTECTION. INSTALL NEW HEAD UNDER LANDING. (PHOTO 54)

CRAWLSPACE ACCESS AND SPACE DOES NOT HAVE SPRINKLER

PROTECTION. PROVIDE SIGNAGE ON ACCESS DOOR. "SPACE FOR SUB

BASEMENT MAINTENANCE ACCESS ONLY. NOT TO BE USED FOR STORAGE.

ACCESS NOT PERMITTED WITHOUT AUTHORIZATION FROM ENGINEERING."

CLEAR OUT ALL ITEMS WITHIN BASEMENT. (PHOTOS 56, 57, & 58)

EXISTING 2 1/2" BUTTERFLY VALVE WITH TAMPER SWITCH TO FEED FLOOR

SPRINKLER ZONE TO REMAIN.

(PHOTOS 27-32, 51-53, & 59-62)

D1

A1

D1

A2

D1

A3

D1

A4

D1

A5

D1

A6

D1

A7

D1

A8

D1

A9

D1

B1

D1

B2

D1

B3

D1

B4

D1

B5

NUCLEAR MEDICINE

A C

CHIEF OF STAFF

B

TV

RAMP DN

ROOF

TEL

24E2 STORAGE

FAC

2479A

ELECTRICAL

CLOSET

24E3

COAT CLOSET

2438C

STORAGE

2438A

TOILET

2438B

STORAGE

2440A

2447A

CONNECTING

CORRIDOR

C2307

CORRIDOR

C2401

ELEVATOR

ELEVATOR

CORRIDOR

C2409

CORRIDOR

C2404

CORRIDOR

C2408

STORAGE

AUTOPSY

AREA

ELEVATOR

NO P4

ELEVATOR

NO P3

ELEVATOR

NO P2

ELEVATOR

NO P1

SOILED

UTILITY

TOILET/

SHOWER

2497A

MORGUE CLEAN UTILITY

REFR

2477A

MECH SPACE

VOLUNTARY

STORAGE

VTS FLEET OPER

2449A

SUPV

OFFICE

2449B

ELEVATOR

NO P7

ELEVATOR

NO P8

PATIENT

ADVOCATE OFFICE

CORRIDOR

C2405

CONFERENCE RM

CPP AND

RESOURCE

TELEPHONE

CLOSET

24T1

STAIR

NO 1

MENS TOILET

STAIR

NO 2

STAFF

OFFICE

ASST TO

DIRECTOR

AUDITORIUM

ELECTRICAL

24E6

CORRIDOR

C2406

STAFF

ATTORNEY

PROGRAM

ANALYST

SECY STAFF

OFFICE

COS

OFFICE

AD OFFICE

ACOS CLINIC

AFFAIRS

OFFICE

STORAGE

BREAK

RM

WOMENS

TOILET

OFFICE

STORAGE

2446D

LOBBY

STRATEGIC

PLANNER

ELECTRICAL

RECEPTION

2444A VESTIBULE

MENS TOILET

STORAGE

2446A

WOMENS TOILET

UNISEX

TOILET

KITCHEN

2446B

CORRIDOR

C2402

STAIR

CORRIDOR

C2403

MECH SPACE

ELEVATOR

FAMILY VIEWING

TOILET

STORAGE

2492A

STAIR

NO 5

ELEVATOR

LAB

INJECTION

RM

PROCESSING

RM

ELECTRICAL

24E5

NUCLEAR MEDICINE

SCANNING AREA

TREATMENT RM

CHIEF OF STAFF

NURSE

EXECUTIVE

STORAGE

AND EQUIP

2446C

DRESSING

RM

2462APIV

PIV

PIV

VISUAL

CO-ORDR

TOILET

2474A

LOW AND

BLIND VISION

TREATMENT RM

STRESS LAB

WAITING

INJECTION RM

NUCLEAR

MED

RECEPTION

HAC

FILE RM

STAFF

PHYSICIAN

SECTION

CHIEF

BONE DENSITY

PROCEDURE RM

OPERATION

MANAGER

STAFF

OFFICE

M-1

NO 5A

2446H

2446F

2446G

WALL PARTITION CLOSETWALL PARTITION CLOSET

FIRE

CLOSET

FIRE

CLOSET

CLEAN

UTILITY

ROOF

ROOF

ELECTRICAL

CLOSET

24E4

B

A

S

O U

T H

B

A

N

O R

T H

B

A

S

O U

T H

B

A

N

O R

T H

B01B

B01A NORTH

D2

A4

D2

A5

D2

A6

D2

A7

D2

A8

D2

A9

D2

B1

D2

B2

D2

B3

D2

C5

D2

C1

D2

C1

D2

C1

D2

A3

D2

A3

D2

C2

D2 c3

D2

C4

D2

C2

D2

C9

D2

D1

C7

D2

OFFICE OF THE DIRECTOR A-120

24E2

STORAGE

ASSISTANT

DIRECTOR

CORRIDOR

C2407

MENS TOILET

2415TEL

STAIR

NO 2

DIRECTOR

OFFICE

TOILET

2413B

STORAGE

2413A

ELECTRICAL

24E1

SECRET

AREA

LOUNGE /

KITCHEN

NORTH PENT HOUSE

BUILDING 30

ASSOCIATE

DIRECTOR

SECRET

SECRET

PUBLIC

AFFAIRS

STAFF

OFFICE

FIRE

CLOSET

ASSISTANT

DIRECTOR

B

U

T H

B

R

T H

B

U

T H

B

R

T H

D2

A1

D2

A2

D2

C1

D2

C2

D2 c3

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions

31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins

Sprinkler Corrections

Jesse Brown VAMC

Chicago, IL

537-16-102A

Project Director

Revisions: Date:

1/8"=1'-0"

4' 8'0 16'

Keyplan:

N

S B01A FX102

BUILDING 01A

SECOND FLOOR PLAN

08/30/2020

100% Complete and Final

Issued for 100% Complete and Final

Issued for 100% CD

08/30/2020

02/10/2020

B01

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions

31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins

Sprinkler Corrections

Jesse Brown VAMC

Chicago, IL

537-16-102A

Project Director

Revisions: Date:

1/8"=1'-0"

4' 8'0 16'

Keyplan:

N

S

FIRE PROTECTION KEYED NOTES:

**THE NOTES PROVIDED HERE CORRESPOND TO THE ASSOCIATED PHOTOS

GENERATED IN THE FIELD REPORT FOR THIS AREA. REFER TO PHOTOS FOR

OBSERVED DEFICIENCIES, DEFECTS, OMISSIONS, AND ERRORS OF THE EXISTING

SPRINKLER SYSTEM. 10-17/18-2019 BUILDING 1 2ND FLOOR & 01-07-2020 FULL

CAMPUS MISSED ROOMS

EXISTING PIPE SLEEVE IS NOT INSERTED INTO WALL CAVITY. REMOVE

PIPE SLEEVE OR INSERT INTO WALL AND FIRE SEAL OPENING. (PHOTO 5)

REPLACE PIPING WITH CORROSION - OUTSIDE ROOM 2444.

(PHOTO 7)

REPLACE THINWALL PIPING WITH CPVC OR SCHEDULE 40 STEEL .

(PHOTOS 8, 22, 35 & 37)

EXIT DOOR FROM ASSEMBLY SPACE BLOCKED. REMOVE ITEMS

BLOCKING EXIT. (PHOTOS 9 & 10)

ADD SPRINKLER PROTECTION AT TOP OF STAIRWELL

(PHOTO 11)

REMOVE STORAGE FROM STAIRWELL ADA SPACE.

(PHOTO 12)

LEAKING CHEMICAL WASTE PIPING ABOVE CEILING. REPLACE DAMAGED

SPRINKLER FITTINGS FROM CHEMICAL WASTE LEAK. (PHOTOS 13 & 14)

REPLACE RUSTED FITTINGS AND PIPING.

(PHOTOS 15 & 16)

REMOVE IMPROPER FIRE SEALANT AND REPLACE WITH NEW. PROVIDE UL

LISTED FIRE SEAL ASSEMBLY. (PHOTO 21)

RELOCATE SPRINKLER HEAD TO BE AWAY FROM LIGHT OBSTRUCTION.

(PHOTO 24)

RELOCATE SPRINKLER HEAD BEING BLOCKED BY HEATER ON WALL.

(PHOTO 25)

REMOVE STORAGE ITEMS TO ALLOW PROPER SPRINKLER CLEARANCES.

MINIMUM 18" FROM DEFLECTOR REQUIRED. (PHOTOS 32 & 33)

SANITARY PIPING LEAKING ABOVE CEILING. REPLACE DAMAGED PIPE

WITH NEW. (PHOTO 34)

REPLACE RUSTED FITTINGS AND PIPING.

(PHOTO 36)

ADD ADDITIONAL HANGER ON CPVC PIPING. EXISTING HANGERS ARE

LOCATED TOO FAR APART. 9 FOOT MAX BETWEEN HANGERS FOR 2 1/2"

PIPING. (PHOTO 41)

REMOVE HANGER ON SPRINKLER PIPING FOR OTHER TRADE EQUIPMENT.

ATTACH LOOSE SUPPORT TO STRUCTURE. (PHOTO 42)

REMOVE TAPE AND PLASTIC AND REPAIR DAMAGED PIPING.

(PHOTO 43)

REMOVE FIRE SEALANT FROM PIPING.

(PHOTO 44)

EXISTING 2 1/2" BUTTERFLY VALVE WITH TAMPER SWITCH TO FEED

FLOOR SPRINKLER ZONE TO REMAIN.

(PHOTOS 1-3. 17-20, 26-30, 38-40, 45, & 46)

TYPICAL TRANSITION FROM STEEL PIPING TO CPVC.

(PHOTOS 4 & 31)

TYPICAL INSTALLATION OF FLEXIBLE DROP SPRINKLER

NO WORK REQUIRED. (PHOTO 6)

FIRE SEALANT INSTALLATION TYPICAL FOR STEAL PIPING

(PHOTO 23)

UNKNOWN LEAK ABOVE CEILING. AIR OR GAS WITNESSED ABOVE

CEILING. PLUG OR SEAL LEAKING PIPE. COORDINATE WITH ENGINEERING.

DEMOLISH UPRIGHT SPRINKLER HEAD ABOVE CEILING.

ADDITIONAL SPRINKLERS REQUIRED IN AREA. PROVIDE HEADS UNDER

SOFFIT ALONG EAST WALL WHERE NO CURRENT HEADS EXIST. ADD 5

NEW HEADS.

ADD SPRINKLER PIPING HANGERS. APPROXIMATELY 20'-0" APART.

PIPE EXTENSION FROM ELBOW TO SPRINKLER IS TOO SMALL. PIPE

REQUIRED TO BE MINIMUM OF 1" DIAMETER. REPLACE WITH PROPER

PIPING. (PHOTO 1)

SPRINKLER AND CEILING HAS WATER SPOTS AND DISCOLORATION.

REPLACE SPRINKLER HEAD AND REMOVE CEILING AND REPLACE WITH

NEW. (PHOTO 2)

BUILDING 1A 2ND FLOOR PLAN NORTH

1/8" = 1'-0"

BUILDING 1A 2ND FLOOR PLAN SOUTH

1/8" = 1'-0"

D2

A1

D2

A2

D2

A3

D2

A4

D2

A5

D2

A6

D2

A7

D2

A8

D2

A9

D2

B1

D2

B2

D2

B3

D2

B4

D2

B5

D2

B6

D2

B7

D2

B8

D2

B9

D2

C1

D2

C6

D2

C7

D2

C8

D2

C2

D2

C3

D2

C4

D2

C5

D2

C9

D2

CARDIOLOGY

DIALYSIS

DIALYSIS

OFFICE

HAC

TOILET

3426A

UNISEX

TOILET

3475A

SOILED

UTILITY

ELECTRICAL CLOSET

3487TOILET

FAC

ELECTRICAL

34E4

BACKUP

GENERATOR RM

3472C

STORAGE

3472B

STORAGE

3455A

ELECTRICAL

3495A

ELECTRICAL

3497A

VESTIBULE/

CHASE

LINEN CHUTE

ELECTRICAL

34E2

TOILET

3443A

VESTIBULE

3439ASUPPLY CLOSET

TOILET

3424A

TOILET

3428A

TOILET

3432A

STORAGE

CLOSET

3434A

TOILET

3429A

TOILET

3427A

MENS

SHOWER

3425A

STORAGE

3485A

FAC

TOILET

3439B

FAC

3447A

CLOSET

CORRIDOR

C3401

NUTRITION AND FOOD

KITCHEN

CORRIDOR

C3402

CORRIDOR

C3404

CORRIDOR

C3403

CORRIDOR

C3406

ELEVATOR LOBBY

ELEVATOR

ELEVATOR

ELEVATOR

P-4

FOOD SVC

AND SUPV

ELEVATOR

P-3

ELEVATOR

P-2

ELEVATOR

P-1

HAC

HAC

OXYGEN

TANKS

DRESSING

ROOM

3475B

STORAGE

3475C LOCKER ROOM

DOCTORS

OFFICE

STAIR

NO 5

RESIDENT

GROUP

DOCTORS

OFFICE

DOCTORS

OFFICE

CHIEF

ENT

DOCTORS

OFFICE

DOCTORS

OFFICE

3494A

DOCTORS

OFFICE

RESIDENT

COORD.

DOCTORS

OFFICE

3488SURGERY STAFF

SECRETARY/

COPIER

HAC

BREAK ROOM

OFFICE

OFFICE

STORAGE

MECH RM

3472A

EQUIPMENT

STORAGE

LAB

MECH RM

3466A

SUPPLY RM

RECEPTION

3461CHIEF OFFICE

3460TANK RM

3454A

STORAGE

3454BDIALYSIS

STORAGE

CARDIO

STORAGE

NON

VA MED

CARE

DIALYSIS RM

DIALYSIS

EQUIPMENT

FILE

STORAGE

SPD SUPPLY

DIALYSIS

SOLUTIONS-B

DIALYSIS

SOLUTIONS-A

STORAGE

STORAGE

WOMENS

TOILET

MECH RM

ELEVATOR

P-7

ELEVATOR

P-8

CLINIC NUTRITION

TEL

34T1

STAIR

NO 1

DIALYSIS

WAITING

NURSE

STATION

LOCKER

3439C

LOUNGE

CRASH CART

STORAGE

STAIR

NO 2

SOCIAL

WORK

NURSE

MGR

OXYGEN TANKS

IV RM

MENS TOILET

LEAD TECH

HEMO DIALYSIS

DIR OFFICE

CONSL MGR

MECH RM

S-5

S-6

CORRIDOR

3468A

ROOF

ROOF

ROOF

ROOF

ELECTRICAL

CLOSET

34E4

B01A NORTH

B

U

T H

B

R

T H

B

U

T H

B

R

T H

B01B

B01A NORTH

D3

A1

D3

A2

D3

A3

D3

A4

D3

A5

D3

A6

D3

A7

D3

A8

D3

A9

D3

B5

D3

C1

D3

B9

D3

B9

D3

B9

D3

C3

1 BED 1 BED

NURSE

HEART STATION

CARDIOLOGY

1 BED

STATION

SUPPLY CLOSET

MENS

SHOWER

3425A

ELECTRICAL CLOSET

34E1

FAC

3411 CLOSET

CORRIDOR

C3405

CRASH CART

STORAGE

OFFICE

CUBICLE

STAIR

NO 2

OFFICE

CUBICLE

SUPPLY

ANALYSIS

SPD

SUPERVISOR

SYSTEM

ANALYST

STORAGE

3406 DIALYSIS

RM

SOCIAL

WORK

NURSE

MGR

MENS TOILET

B

U

T H

B

R

T H

B

U

T H

B

R

T H

D3

B9

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions

31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins

Sprinkler Corrections

Jesse Brown VAMC

Chicago, IL

537-16-102A

Project Director

Revisions: Date:

1/8"=1'-0"

4' 8'0 16'

Keyplan:

N

S B01A FX103

BUILDING 01A

THIRD FLOOR PLAN

08/30/2020

100% Complete and Final

Issued for 100% Complete and Final

Issued for 100% CD

08/30/2020

02/10/2020

B01

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions

31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins

Sprinkler Corrections

Jesse Brown VAMC

Chicago, IL

537-16-102A

Project Director

Revisions: Date:

1/8"=1'-0"

4' 8'0 16'

Keyplan:

N

S

BUILDING 1A 3RD FLOOR PLAN NORTH

1/8" = 1'-0"

BUILDING 1A 3RD FLOOR PLAN SOUTH

1/8" = 1'-0"

FIRE PROTECTION KEYED NOTES:

**THE NOTES PROVIDED HERE CORRESPOND TO THE ASSOCIATED PHOTOS

GENERATED IN THE FIELD REPORT FOR THIS AREA. REFER TO PHOTOS FOR

OBSERVED DEFICIENCIES, DEFECTS, OMISSIONS, AND ERRORS OF THE

EXISTING SPRINKLER SYSTEM. 10-18/21-2019 BUILDING 1 3RD FLOOR &

01-07-2020 FULL CAMPUS MISSED ROOMS.

REPLACE RUSTED HANGER ROD

(PHOTO 1)

REPLACE FIRESTOPPING ON PIPING THROUGH WALL PENETRATION.

REMOVE EXISTING AND REPLACE WITH NEW. (PHOTO 2)

RELOCATE SPRINKLER HEAD TO MINIMIZE OBSTRUCTION FROM

PIPING. (PHOTO 8)

REPLACE PIPING THAT IS RUSTED.

(PHOTO 9)

ADD ADDITIONAL SPRINKLER HEAD TO COVER AREA BLOCKED BY

COLUMN. (PHOTO 12)

ADD NEW SPRINKLER HEAD IN DRYWALL CEILING THAT DOES NOT

HAVE COMPLETE COVERAGE. (PHOTO 17)

REPLACE BURNT CPVC PIPING WITH NEW.

(PHOTO 18)

INSTALL NEW SPRINKLER HEAD IN CORRIDOR WHERE SPRINKLER

COVERAGE MISSING. (PHOTO 19)

ADD 7 NEW SPRINKLER HEADS UNDER DUCTWORK IN KITCHEN.

DUCTWORK GREATER THAN 48" WIDE REQUIRED TO HAVE SPRINKLER

PROTECTION UNDERNEATH. CONTRACTOR SHALL USE SIDEWALL

HEADS WITH HEAD GUARDS TO MAXIMIZE CLEARANCE TO FLOOR.

(PHOTO 20)

TYPICAL DRY PENDANT SPRINKLER HEAD DROP INTO COOLER.

VERIFY SPRINKLER LISTING TO ENSURE INSTALLATION IS CORRECT

WITH ADDITIONAL TEE FITTING PRIOR TO DRY PENDANT. (PHOTO 21)

REPLACE RUSTED DRY PENDANT SPRINKLER HEAD IN COOLER.

(PHOTOS 22, 23, & 24)

REMOVE SPRINKLER HEADS ABOVE DROP CEILING.

(PHOTO 25)

ACCESS PANEL INACCESSIBLE ABOVE DROP CEILING. PROVIDE

SIGNAGE ON CEILING TO IDENTIFY LOCATION OF ACCESS PANEL.

(PHOTO 26)

REMOVE SPRINKLER HEAD OBSTRUCTED BY PIPING. ADJACENT

SPRINKLER HEAD PROVIDES COVERAGE. (PHOTO 27)

TYPICAL TRANSITION BETWEEN STEEL PIPING AND CPVC. NO WORK

TO BE DONE. (PHOTO 28)

DEMOLISH SPRINKLER HEAD INSTALLED TOUCHING WALL IN

STAIRWELL. ADJACENT SPRINKLER HEAD LESS THAN 7'-6" FROM DOOR

AND WILL PROVIDE COVERAGE. (PHOTOS 32 & 33)

REPLACE RUSTED SPRINKLER HEAD IN FREEZER.

(PHOTOS 38 & 39)

EXISTING 2 1/2" BUTTERFLY VALVE WITH TAMPER SWITCH TO FEED

FLOOR SPRINKLER ZONE TO REMAIN.

(PHOTOS 3-7, 10-15, 29-31 & 34-37)

PROVIDE NEW SPRINKLER HEAD IN DROP DOWN SOFFIT. ADJACENT

SPRINKLERS DO NOT PROVIDE COMPLETE COVERAGE. (PHOTO 40)

ADD SPRINKLER PROTECTION IN HOOD.

(PHOTO 41)

DEFLECTOR ON HEAD BENT. REPLACE SPRINKLER. (PHOTO 3)

D3

A1

D3

A2

D3

A3

D3

A4

D3

A5

D3

A6

D3

A7

D3

A8

D3

A9

D3

B1

D3

B2

D3

B3

D3

B4

D3

B5

D3

B6

D3

B7

D3

B8

D3

B9

D3

C1

D3

C2

D3

C2

DN UP

FEC

DNUP

UP DN

PANORAMIC RM

ELECTRIC

CLOSET

44E5

MED

CLOSET

SOILED

SPD CART

HOLDING

TEL/DATA

44T2

CLEAN SUPPLY

CONTROL RM

BARIATRIC

TOILET

SOILED UTILITY

NITROUS TANK

STORAGE

VESTIBULE/CHASE

4507 LINEN CHUTE

ELECTRICAL

CLOSET

ELECTRICAL

44E2

CLOSET

4447A

OLD CLOSET

4496A

ELECTRIC/

FAC CLOSET

44E4

TREATMENT BAY

4418A

CORRIDOR

C4501

CORRIDOR

C4408

CORRIDOR

C4404

CORRIDOR

C4402

CORRIDOR

C4401

PATHOLOGY

RESIDENTS

NEUROLOGY

OFFICE

NURSE

OFFICE

STAFF LOUNGE

ELEVATOR

P-7

ELEVATOR

P-8

MOVE COORD

STORAGE

ELEVATOR

LOBBY

ELEVATOR

P-1

ELEVATOR

P-2

ELEVATOR

P-3

ELEVATOR

P-4

ELEVATOR

S-5

ELEVATOR

S-6

MED OFFICE

LOCKER

JANITOR

CLOSET

TOILET TOILET

TOILET TOILET

PATIENT

TOILET

SURGY

MGR

RECOVERY BAY

STAIR

NO 5

SURGY

TEAM RM

PATIENT

TOILET

OFFICE

MAXILLOFACIAL- 4 MAXILLOFACIAL-3

CONE BEAM

MAXILLOFACIAL-1

MAXILLOFACIAL-2

INSTRUMENT

PREP

ORAL SURGY RM

ORAL SURGY RM

CORRIDOR

C4403

OFFICE

ENDOSCOPY-2

ENDOSCOPY-1

STORAGE

CONSULT RM

PERIODONTAL-1

PERIODONTAL-2

INSTRUMENT

PREP

CLEAN

LINEN

MECH RM

RECEPTION / ADMISSION

4427A

WAITINGWAITING

TEL

44T1

STAIR

NO 1

CORRIDOR

C4405

CORRIDOR

C4406

ORAL SURGERY-2

INSTRUMENT

PREP

HYGIENIST

OFFICE PREP

ORAL SURGERY-1

TREATMENT BAY

MECH RM

OFFICE

OFFICE

INSTRUMENT

PREP

ORAL

SURGERY-3

OFFICE

STAIR

NO 2

TREATMENT BAY

ROOF

ROOF

ROOF

ROOF

ROOF

ELECTRICAL

CLOSET

44E3

CORRIDOR4427B

STORAGE

B

U

T H

B

R

T H

B

U

T H

B

R

T H

B01B

B01A NORTH

D4

B5

D4

B6

D4

B7

D4

B8

D4

B9

D4

C1

D4

C4

D4

C2

D4

C2

D4

C2

D4

B8

FEC

FEC

DN UP

PANORAMIC RM

ELECTRICAL

CLOSET

SOILED

SPD CART

HOLDING

4405A

STORAGE

4407A

CONTROL RM

ELECTRICAL

CLOSET

4417CORRIDOR

C4407

ORAL SURGERY-2

OFFICE

STAIR

NO 2

TREATMENT BAY

4407ALCOVE

TREATMENT BAY

HYGIENIST

STORAGE

RESIDENT

TEAM RM

MODEL

MAKING

CERAMICS

LAB

4401A

LAB

44E1

B

U

T H

B

R

T H

B

U

T H

B

R

T H

D4

B5

D4

B6

D4

C2

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions

31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins

Sprinkler Corrections

Jesse Brown VAMC

Chicago, IL

537-16-102A

Project Director

Revisions: Date:

1/8"=1'-0"

4' 8'0 16'

Keyplan:

N

S B01A FX104

BUILDING 01A

FOURTH FLOOR PLAN

08/30/2020

100% Complete and Final

Issued for 100% Complete and Final

Issued for 100% CD

08/30/2020

02/10/2020

B01

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions

31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins

Sprinkler Corrections

Jesse Brown VAMC

Chicago, IL

537-16-102A

Project Director

Revisions: Date:

1/8"=1'-0"

4' 8'0 16'

Keyplan:

N

S

BUILDING 1A 4TH FLOOR PLAN NORTH

1/8" = 1'-0"

BUILDING 1A 4TH FLOOR PLAN SOUTH

1/8" = 1'-0"

FIRE PROTECTION KEYED NOTES:

**THE NOTES PROVIDED HERE CORRESPOND TO THE ASSOCIATED PHOTOS

GENERATED IN THE FIELD REPORT FOR THIS AREA. REFER TO PHOTOS FOR

OBSERVED DEFICIENCIES, DEFECTS, OMISSIONS, AND ERRORS OF THE

EXISTING SPRINKLER SYSTEM. 10-21/22-2019 BUILDING 1 4TH FLOOR.

REMOVE WIRE FROM LIGHT ON SPRINKLER PIPING. ADD HANGER TO SUPPORT

WIRE AND SEPARATE FROM TOUCHING PIPING. WIRE STARTING TO CUT

GROOVE IN PLASTIC PIPING. (PHOTO 5)

CLEAN GREASE OFF PIPING. IF CORROSION PRESENT REPLACE PIPING.

(PHOTO 6)

UNFINISHED SPACE SPRINKLER HEAD TOO LOW FROM CEILING. RAISE

SPRINKLER HEAD UP TO WITHIN 12" OF DECK. (PHOTO 7)

SPRINKLER HEAD REQUIRED ABOVE AND BELOW UNFINISHED CEILING.

PROVIDE TWO HEADS FOR PROPER PROTECTION. (PHOTO 8)

REPLACE CORROSIVE STEEL PIPING.

(PHOTO 9)

CLEAN PIPING, IF CONSTRUCTION PLASTER, NO WORK REQUIRED. IF

CORROSION REPLACE PIPING. (PHOTO 10)

REPLACE RUSTED FITTINGS.

(PHOTO 11)

SPRINKLER PIPING RUNNING THROUGH DUCTWORK INSULATION. REMOVE

INSULATION AND CHECK PIPING. REPLACE IF RUSTED. REPAIR INSULATION

WITH SPRINKLER PIPING OUTSIDE. (PHOTO 15)

DRY PENDANT HEAD IN COOLER. CHECK LISTING IF TEE PRIOR TO DRY PIPE IS

PERMITTED. (PHOTO 16)

REPAIR CEILING TILE WHERE HOLE FOR SPRINKLER HEAD CUT TOO LARGE.

(PHOTO 17)

REMOVE ZIP TIE AND WIRE ATTACHED TO PIPE.

(PHOTO 18)

DAMAGED EXIT SIGN. ONLY ONE SIDE ILLUMINATED.

(PHOTO 25)

PROVIDE ADDITIONAL HEAD UNDER DUCTWORK.

(PHOTO 26)

DEMOLISH SPRINKLER HEAD ABOVE CEILING OVER FIRE HOSE VALVE CABINET.

(PHOTO 29)

ADJUST HANGER TO ENSURE BRACING IS PROPERLY INSTALLED TIGHT TO PIPE.

(PHOTO 30)

NEW CPVC PIPING ROUGHED-IN BUT NOT CONNECTED TO WATER SUPPLY.

(PHOTO 31)

REINSTALL REMOVED SPRINKLER HEAD. NOT ENOUGH COVERAGE IN ROOM.

(PHOTOS 32 & 33)

ADD ADDITIONAL SPRINKLER HEAD. HEAD TOO FAR FROM WALL.

(PHOTO 37)

REMOVE/RELOCATE MATTRESS STORAGE IN CORRIDOR. SPACING TO

SPRINKLER HEAD LESS THAN MINIMUM REQUIRED DISTANCE OF 18".

(PHOTO 38)

EXISTING 2 1/2" BUTTERFLY VALVE WITH TAMPER SWITCH TO FEED FLOOR

SPRINKLER ZONE TO REMAIN. (PHOTO 1-4, 12-14, 19-24, 27-28, & 34-36)

SPRINKLER HEAD SHOWN HERE NOT INSTALLED. INSTALL HEAD IN THIS

LOCATION.

MECHANICAL SPACE IS COLD, PULLING AIR FROM EXPOSED EXTERIOR. IF

UNCHECKED SPRINKLER HEADS IN SPACE WILL FREEZE WHEN OUTSIDE

TEMPERATURES DROP. ENGINEERING TO ACCESS HOW TO BLOCK EXTERIOR

AIR FROM SPACE. WORK OUTSIDE SPRINKLER SCOPE.

D4

A1

D4

A2

D4

A3

D4

A4

D4

A5

D4

A6

D4

A7

D4

A8

D4

A9

D4

B1

D4

B2

D4

B3

D4

B4

D4

B5

D4

B6

D4

B7

D4

B8

D4

B9

D4

C1

D4

C2

D4

C3

D4

C4

STORAGE

SUPPLY CLOSET

FIRE CLOSET

5447A

WOMENS

LOCKER

TOILET

5434A

TOILET

5430A

DRESSING

RM

DRESSING

RM

TOILET

5429A

TOILET

5425A

TOILET

5423A

SOILED

UTILITY

LOCKER

RM

CLEAN LINEN

TOILET

5424A

TOILET

5439A

TOILET

5433A

ELECTRICAL

PANEL

54E4SUPPLY CLOSET

ELECTRICAL

CLOSET

5412A

STORAGE

5496A

TELECOM

CLOSET

54E2

REGISTRATION

DESK

ELECTRICAL

CLOSET

54E5

CORRIDOR

C5406

CORRIDOR

C5401

CORRIDOR

C5402

CORRIDOR

C5403

CORRIDOR

C5404

CORRIDOR

5500C

MENS TOILET

GROUP RM

PROCEDURE RM

RESEARCH

OFFICE

MEDICINE

PREP

STAIR

NO 2

EQUIPMENT

STORAGE

EXAM RM

EXAM RM

DAY

SURGY

EXAM RM

PHARMACIST

OFFICE

TOILET

5435A

TOILET

5436A

OFFICE

PSYCHOLOGIST

EXAM RM

EXAM RM

NURSE

STATION

BREAK

RM

WAITING RM

LINEN

HAC

5440 PATIENT

EDUCATION

RM

CLEAN

SUPPLY

TOILET

WAITING AREA

OFFICE

DOCTOR

LOUNGE

HAC

5462 CLEAN LINEN

TOILET

TOILET

5458A

MENS

LOCKER

NURSE

STATION

TOILET

RECOVERY AREA

DRESSING

TOILET

STORAGE

TOILET

5482 PROCEDURE

RM-5

PROCEDURE

RM-4

SCOPE

REPROCESSING

CLEAN RM

PROCEDURE

RM-3

PROCEDURE

RM-2

SUPPLY

CLEANING RM

MECH

RM

5489PROCEDURE

RM-1

STAIR

NO 5

OFFICE

MED

ATTEND

NURSE

MGR

FELLOW

OFFICE

OFFICE

ENDO

OFFICE

ENDO

DIRECTOR

SPD

SUPPLIES

ELEVATOR

P-1

ELEVATOR

P-2

ELEVATOR

P-3

ELEVATOR

P-4

ELEVATOR

S-5

ELEVATOR

S-6

TEL

54T1

STAIR

NO 1

CHECK-IN

ELEVATOR

P-8

ELEVATOR

P-7

FIRE/ELECTRICAL CLOSET

5417A

SERVICE

ELEVATOR

ROOF

ROOF

ROOF

ROOF

ROOF

ELECTRICAL CLOSET

54E3

UNISEX TOILET

UNISEX TOILET

DRESS

RM

DRESS

RM

TOILET

STAFF LOCKER RM

TRAINING RM

FILE

CABINET

VESTIBULE/CHASE

TOILET

CORRIDOR

C5501

B

A

S

O U

T H

B

A

N

O R

T H

B

A

S

O U

T H

B

A

N

O R

T H

B01B

B01A NORTH

D5

A1

D5

A2

D5

A3

D5

A4

D5

A5

D5

A6

D5

A7

D5

A8

D5

A7

D5

A7

D5

A7

D5

B2

D5

B2

D5

B2

SICU SUPPLY CLOSET

UNISEX

TOILET

ELECTRICAL

CLOSET

54E1

DIRTY LINEN

5400B

CLEAN LINEN

5400A

TOILET

5423A

RECEPTION

AREA

CORRIDOR

C5405

RESEARCH

OFFICE

MEDICINE

PREP

STAIR

NO 2

TEAM RM

LOCKER

5412LOUNGE

TREATMENT BED-5

TREATMENT BED-4

TREATMENT BED-3

TREATMENT BED-2

TREATMENT BED-1

TOILET

5406A

WAITING

EQUIPMENT

STORAGE

EXAM RM

FIRE/ELECTRICAL CLOSET

B

U

T H

B

R

T H

B

U

T H

B

R

T H

D5

B2

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions

31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins

Sprinkler Corrections

Jesse Brown VAMC

Chicago, IL

537-16-102A

Project Director

Revisions: Date:

1/8"=1'-0"

4' 8'0 16'

Keyplan:

N

S B01A FX105

BUILDING 01A

FIFTH FLOOR PLAN

08/30/2020

100% Complete and Final

Issued for 100% Complete and Final

Issued for 100% CD

08/30/2020

02/10/2020

B01

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions

31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins

Sprinkler Corrections

Jesse Brown VAMC

Chicago, IL

537-16-102A

Project Director

Revisions: Date:

1/8"=1'-0"

4' 8'0 16'

Keyplan:

N

S

BUILDING 1A 5TH FLOOR PLAN NORTH

1/8" = 1'-0"

BUILDING 1A 5TH FLOOR PLAN SOUTH

1/8" = 1'-0"

FIRE PROTECTION KEYED NOTES:

**THE NOTES PROVIDED HERE CORRESPOND TO THE ASSOCIATED PHOTOS

GENERATED IN THE FIELD REPORT FOR THIS AREA. REFER TO PHOTOS FOR

OBSERVED DEFICIENCIES, DEFECTS, OMISSIONS, AND ERRORS OF THE

EXISTING SPRINKLER SYSTEM. 10-22-2019 BUILDING 1 5TH FLOOR.

ALUMINUM FOIL USED IN LIEU OF FIRE SEALANT. REMOVE AND INSTALL

FIRE SEALANT FOR PENETRATION. (PHOTO 1)

REPLACE HANGER AND CONNECT TO ROD ATTACHED TO DECK

(PHOTO 5)

REMOVE WIRING WRAPPED AROUND PIPING. REVISE WIRING TO AVOID

RUNNING ON PIPING. ADD HANGER TO SUPPORT WIRE. (PHOTO 6)

CORROSION ON SANITARY PIPING OVERHEAD SPRINKLER LINE.

REPLACE DAMAGED SANITARY PIPING. (PHOTO 10)

REPLACE RUSTED SPRINKLER ESCUTCHEON.

(PHOTO 11)

PROVIDE ADDITIONAL HANGERS ON SPRINKLER PIPING. PIPE SAGGING.

(PHOTO 12)

REPLACE BURNT FITTINGS AND PIPING WITHIN CORRIDOR. NUMBER OF

AREAS WHERE BURN MARKS NOTICED. (PHOTOS 13-17)

REPLACE VICTAULIC COUPLING AND REPLACE WITH CPVC.

(PHOTO 21)

ADD SPRINKLER HEAD ON OPPOSITE SIDE OF EXIT SIGN OR RELOCATE

SIGN SO NOT OBSTRUCTING SPRINKLER HEAD. (PHOTO 25)

REPAIR CEILING WHERE SPRINKLER PENETRATION LARGER THAN

SPRINKLER ESCUTCHEON AND OPENING VISIBLE. (PHOTO 27)

EXISTING 2 1/2" BUTTERFLY VALVE WITH TAMPER SWITCH TO FEED

FLOOR SPRINKLER ZONE TO REMAIN. (PHOTOS 2-4, 7-9, 18-20, 22-24 & 26)

D5

A1

D5

A2

D5

A3

D5

A4

D5

A5

D5

A6

D5

A7

D5

A8

D5

A9

D5

B1

D5

B2

SHOWER

AREA

LOCKER LOCKER

STORAGE

TOILET

6423A

SIMULATION LAB

SUPPLY

ATTENDING

SOIL ROOM

TOILET

6461A

TOILET

6457A

LINEN CHUTE

FAC

NURSE UNION

ELECTRICAL

64E4

TOILET

6471A

TOILET

6473A

TOILET

6477A

E E O

STORAGE

6466TOILET

6468A

TOILET

6470A

TOILET

6472A

TOILET

6476A

TOILET

6422A

TOILET

6424A

TOILET

6426A

TOILET

6430A

ELECTRICAL

CLOSET

64E1

SUPPLY

TOILET

6425A

TOILET

6427A

TOILET

6431A

ELECTRICAL

CLOSET

64E2

TOILET

6439A

TOILET

6435A

FAC

PHONE

6453A

CLOSET

6497A

CORRIDOR

C6404

GENERAL

FOREMAN EMS

OFFICE

EMS SUPV

OFFICE

ELEVATOR

P-1

ELEVATOR

P-4

ELEVATOR

P-3

ELEVATOR

P-2

ELEVATOR

ELEVATOR

ELEVATOR

LOBBY

NURSE RECRUITER

ELEVATOR

P-7

ELEVATOR

P-8

CHIEF UROLOGY

OFFICE

TEL

64T1

6469A

CORRIDOR

C6402

STORAGE

CORRIDOR

C6403 CORRIDOR

C6401

STAIR

NO 1

NURSE

OFFICE

SOCIAL

WORKER

OFFICE

RECEPTION

RECEPTION

STAIR

NO 2

OFFICE

OFFICE

6434A

STORAGE

VACANT

6482STORAGE

SINK RM

FILE

STORAGE

STORAGE

TELE MOVE

PGM OFFICE

OFFICE

HOME

TELEHEALTH

STORAGE

6462A

SAFETY

STORAGE

STORAGE

UNISEX TOILET

STAIR

NO 5

UNION SEIU

6484 UNASSIGNED SPACE

PRIVACY/FOIA

NURSES UNION

6493 TEAM RM

CLINIC NUTRITION

EEO FILE

STORAGE

SUPPLY

EEO

ASSISTANT

ETHIC

CONSULTATION

CHAPLAIN OFFICE

CHAPLAIN OFFICE

LACTATION RM

CHAPLAIN OFFICE

E E O ASST

OFFICE

E E O PGM MGR

SOCIAL

WORKER

OFFICE

CLINICAL CHAPLAIN

OFFICE

CLINICAL

CHAPLAIN

OFFICE

HR

SPECIALIST

HAC

6460INFO SECURITY OFFICE

6412 GERIATRIC TEAM RM

ACS OFFICE

COMPLIANCE

OFFICE

ADMIN.

OFFICE

6444A

CUSTOMER

SVC

ORGAN

TRANSPLANT

CO-ORDR

CONFERENCE RM

FILE RM

KITCHEN

HAC

6436STORAGE

SUPPLY

OAA

OFFICE

SAFETY

SPECIALIST

SAFETY

MANAGER

INFO

SECURITY

OFFICE

HUD VASH

NURSE OFFICE

SOCIAL

WORKER

OFFICE

HUD VASH

HR

SPECIALIST

VASCULAR

OFFICE

SOCIAL

WORKER

OFFICE

SOCIAL WORKER

OFFICE

CLOSET

6435A

TOILET/SHOWER

6447A

S5

S6

SUPPLY

STORAGE

ROOF

ROOF

ROOF

ROOF

ROOF

ELECTRICAL CLOSET

64E3

B01B

B01A NORTH

B

U

T H

B

R

T H

B

U

T H

B

R

T H

B01B

B01A NORTH

D6

A1

D6

A2

D6

A9

SHOWER

AREA

STORAGE

TOILET

6423A

WATER

FOUNTAIN

FAC

STORAGE

STAIR

NO 2

STORAGE

UNISEX STAFF

TOILET

NURSE OFFICE

NURSE OFFICE

DOCTOR

OFFICE

NURSE OFFICE

6402 WAITING

INFO SECURITY OFFICE

SUPPLY

SAFETY

SPECIALIST

FIT

TESTING

6406A

B

U

T H

B

R

T H

B

U

T H

B

R

T H

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions

31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins

Sprinkler Corrections

Jesse Brown VAMC

Chicago, IL

537-16-102A

Project Director

Revisions: Date:

1/8"=1'-0"

4' 8'0 16'

Keyplan:

N

S B01A FX106

BUILDING 01A

SIXTH FLOOR PLAN

08/30/2020

100% Complete and Final

Issued for 100% Complete and Final

Issued for 100% CD

08/30/2020

02/10/2020

B01

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions

31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins

Sprinkler Corrections

Jesse Brown VAMC

Chicago, IL

537-16-102A

Project Director

Revisions: Date:

1/8"=1'-0"

4' 8'0 16'

Keyplan:

N

S

BUILDING 1A 6TH FLOOR PLAN NORTH

1/8" = 1'-0"

BUILDING 1A 6TH FLOOR PLAN SOUTH

1/8" = 1'-0"

FIRE PROTECTION KEYED NOTES:

**THE NOTES PROVIDED HERE CORRESPOND TO THE ASSOCIATED PHOTOS

GENERATED IN THE FIELD REPORT FOR THIS AREA. REFER TO PHOTOS FOR

OBSERVED DEFICIENCIES, DEFECTS, OMISSIONS, AND ERRORS OF THE

EXISTING SPRINKLER SYSTEM. 11-01-2019 BUILDING 1 6TH FLOOR.

CPVC PIPE IS BURNED.

(PHOTO 1)

CPVC PIPE IS YELLOW AND BURNED.

(PHOTO 2)

FITTING IS RUSTED. REPLACE WITH NEW FITTING.

(PHOTO 3)

FITTING IS RUSTED. REPLACE WITH NEW FITTING.

(PHOTO 4)

FITTING IS RUSTED. REPLACE WITH NEW FITTING.

(PHOTO 5)

CPVC PIPE IS BURNED.

(PHOTO 6)

CLEAN FIRE STOP OFF OF PIPE.

(PHOTO 7)

SPRINKLER IS NEEDED TO COMPLETE COVERAGE UNDER DUCT.

ADD SPRINKLER UNDER DUCT. (PHOTO 8)

ADD HANGER TO CPVC. (PHOTO 9)

D6

A1

D6

A2

D6

A3

D6

A4

D6

A5

D6

A6

D6

A7

D6

A8

D6

A9

BIO-MED

TOILET

7424A

TOILET

7423A

TOILET

7437AELECTRICAL

74E1

PHONE

CLOSET

7451B

FIRE CT

7447A

FIRE CLOSET

CORRIDOR

C7402

CORRIDOR

C7404

VESTIBULE/

CHASE

DR ZIMMERMAN

CONFERENCE RM

EMS EQUIP

ELEVATOR

LOBBY

MECH A/C

ELEVATOR

P-1

ELEVATOR

P-2

ELEVATOR

P-3

ELEVATOR

P-4

ELEVATOR

S-6

ELEVATOR

S-5

CHIEF MED SVC

ELEVATOR

P-7

ELEVATOR

P-8

OFFICE

SUPPLY

SPECIALIST

74T1

STAIR

NO 1

ELECTRICAL

74E2

SUPPLY

TECH

STAIR

NO 2

ICE

M/C

STORAGE

STORAGE

7450A

STORAGE

WAITING RM

PATIENT EFFECTS UNIFORM EXCHANGE

SATV

BIOMED

SHOP

TOILET

7412A

BIOMED

SHOP

BIOMED

SHOP

CART

STORAGE

CABLE RM

REFERENCE BOOK RM

STORAGE

TOILET

7421A BIOMED

CHIEF

ICE M/C

TOILET

7422A

BIOMED

SHOP

BIOMED

SHOP

BIOMED

SHOP

BIOMED

SHOP

BIOMED

SHOP

BIOMED

SHOP

SUPV OFFICE

TELECOM

MGR

BREAKRM/

ALT

CONFERENCE

IRM

CHIEF

IRM

ASST

CHIEF

NEW AIR

HANDLER RM

HELP DESK

AREA

OFFICE

AREA

WOMEN'S

TOILET

UTILITY

CLOSET

COMPUTER LAB

AND STAGING

DATA

CENTER

CART

CLOSET

OFFICE

AREA

ELECTRICAL

CLOSET

UNISEX

TOILET

74H2

MEN'S

TOILET

SECURE

STORAGE 2

OFFICE

AREA

CLOSET

SECURE

STORAGE 1

OFFICE AREA

OFFICE

AREA

STAIRWELL

ELECTRIC

CLOSET

74E3

BIOMED

SERVER

ROLL-UP WINDOW ELECTRICAL

B01B

B01A NORTH

B

U

T H

B

R

T H

B

U

T H

B

R

T H

B01B

B01A NORTH

D7

A1

D7

A2

D7

A4

D7

A5

SHOWER

FIRE CLOSET

CORRIDOR

C7403

STAIR

NO 2

ICE

M/C

STORAGE

MENS TOILET

HAC

EQUIP STORAGE

EQUIP STORAGE

EQUIP STORAGE

EQUIP STORAGE

BIOMED

SHOP

TOILET

7412A

BIOMED

SHOP

BIOMED

SHOP

REFERENCE BOOK RM

TOILET

7421A

B

U

T H

B

R

T H

B

U

T H

B

R

T H

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions

31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins

Sprinkler Corrections

Jesse Brown VAMC

Chicago, IL

537-16-102A

Project Director

Revisions: Date:

1/8"=1'-0"

4' 8'0 16'

Keyplan:

N

S B01A FX107

BUILDING 01A

SEVENTH FLOOR PLAN

08/30/2020

100% Complete and Final

Issued for 100% Complete and Final

Issued for 100% CD

08/30/2020

02/10/2020

B01

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions