This document provides details on a federal contract solicitation from the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 12. Solicitation number 36C25222B0007 seeks corrections to a sprinkler system at Project 537-16-102A. The opportunity type is listed as a solicitation. The description indicates the solicitation is for corrections to the sprinkler system at the specified project location, with no other details provided.
View the file
Other files
Show all 46
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REFER
KEYNOTE
EQUIPMENT TAG
GENERAL SYMBOLS
ELEVATION SYMBOL
DETAIL REFERENCE (TOP=DETAIL NUMBER,
BOTTOM=DRAWING NUMBER)
PLAN CONTINUATION REFERENCE
(BOTTOM=DRAWING NUMBER)
SECTION DESIGNATION (TOP=SECTION
NUMBER, BOTTOM=DRAWING NUMBER)
POINT OF NEW CONNECTION TO EXISTING
WHEN ON DEMO SHEET: END POINT OF DEMO
X0.0
FEC
FLOW SWITCH
FVC
FHC
DRY PIPE VALVE ASSEMBLY
PREACTION VALVE ASSEMBLY
SPRINKLER ZONE CONTROL
FIRE ALARM BELL
VALVE ASSEMBLY
FPTH
FDC
FDV
FIRE PROTECTION SYMBOLS
B
FIRE DEPARTMENT CONNECTION
FIRE PUMP TEST HEADER
FIRE DEPARTMENT VALVE
ROOF TOP TEST HEADER
FIRE HOSE CABINET
FIRE VALVE CABINET
FIRE EXTINGUISHER (WALL HUNG)
FIRE EXTINGUISHER CABINET
PUMP
FIRE PROTECTION ANNOTATION
FIRE SUPPLY
SPRINKLER PIPE
DRY SPRINKLER PIPE
SPR
DSPR
F
CLEAN AGENTCLA
DIAMETERDIA
ACCESS PANELAP
AFF ABOVE FINISHED FLOOR
ADJ ADJUSTABLE
CLG
CL
CEILING
CENTERLINE
MINIMUM
PRESSURE REDUCING VALVE
RPBP
SCH
RPM
REDUCED PRESSURE ZONE
SCHEDULE
REVOLUTIONS PER MINUTE
PSIG
PSI
NTS
OD
OC
NPT
MTG
MTD
POUNDS PER SQUARE INCH GAUGE
POUNDS PER SQUARE INCH
ON CENTER
NATIONAL PIPE THREAD
NOT TO SCALE
OUTSIDE DIAMETER
TYP
PRV
TYPICAL
MOUNTING
MOUNTED
MIN
SPR SPRINKLER
V VALVE
GALLONS PER MINUTE
FIRE PUMP TEST HEADER
INSIDE DIAMETER
IN
ID
GPM
GA
GAL
FPTH
INCHES
GAUGE
GALLON
FHC FIRE HOSE CABINET
ELEV ELEVATION
MAX MAXIMUM
POUNDS PER SQUARE FOOTPSF
FLOORFLR
FIRE VALVE CABINETFVC
BOTTOM OF PIPEBOP
IE INVERT ELEVATION
FDC FIRE DEPARTMENT CONNECTION
FLOW SWITCHFS
FDV FIRE DEPARTMENT VALVE
FIRE PUMP CONTROLLERFPC
DSP DRY SPRINKLER PIPE
HUB DRAINHD
JPC
JP
JOCKEY PUMP CONTROLLER
JOCKEY PUMP
F FIRE SUPPLY
FACP FIRE ALARM CONTROL PANEL
VESDA VERY EARLY SMOKE DETECTION APPARATUS
AIR COMPRESSORAC
ACC ACCESS
RV RELIEF VALVE
BACKFLOW PREVENTER
EX EXISTING
GALV
GALVANIZED
DOUBLE DETECTOR CHECK ASSEMBLYDDCA
ABBREVIATIONS
CSP COMBINED SPRINKLER STANDPIPE RISER
SP STAND PIPE
SD SPRINKLER DRAIN
DRY PIPEDP
1. THE CONTRACTORS WORK SHALL CONFORM TO THE
OWNERS POLICIES ON CONSTRUCTION PROCEDURES.
2. COORDINATE WITH THE OWNER FOR ANY EQUIPMENT
REMOVED THAT NEEDS TO BE RETURNED TO THE OWNER.
3. COORDINATE WITH OWNER FOR ANY TEMPORARY SYSTEM
SHUTDOWNS NECESSARY TO COMPLETE THE WORK.
4. PATCH PIPING RISERS AS REQUIRED.
5. COORDINATE WITH OWNER FOR ANY FLOOR CORING
WORK THAT IS REQUIRED.
6. ANY MODIFIED OR ADDED SPRINKLERS SHALL BE PIPED
USING THE INSTALLED BUILDING PIPE SCHEDULE SINCE
THIS HAS BEEN HYDRAULICALLY CALCULATED.
GENERAL FIRE PROTECTION NOTES
1. THE FIRE PROTECTION DEMOLITION DRAWINGS SHOW
EXISTING PIPING, EQUIPMENT AND DEVICES WHICH ARE
INTENDED TO BE REMOVED. THESE DRAWINGS INDICATE THE
REQUIRED SCOPE OF WORK AND ARE NOT INTENDED TO
REFER TO EVERY PIECE OF EQUIPMENT OR PIPE THAT MUST
BE REMOVED IN ORDER TO COMPLETE THE WORK. IT SHALL
BE THE CONTRACTOR'S RESPONSIBILITY TO VISIT THE SITE
AND VERIFY THE CURRENT INSTALLATION BEFORE
SUBMITTING A BID FOR THE WORK.
2. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY
THE CONDITION OF ALL EXISTING EQUIPMENT. EXACT SIZES
OF EXISTING PIPING, ETC. BEFORE DEMOLITION WORK IS
BEGUN. REPORT ANY DISCREPANCIES BETWEEN PLANS AND
ACTUAL FIELD CONDITIONS TO ARCHITECT AND ENGINEER
PRIOR TO THE COMMENCEMENT OF DEMOLITION WORK.
3. WHERE DEMOLITION WORK WILL INTERRUPT FIRE
PROTECTION SERVICE TO AREAS OF THE FACILITY THAT ARE
TO REMAIN IN OPERATION, COORDINATE ANY INTERRUPTIONS
WITH THE OWNER AT LEAST TWO WEEKS PRIOR AND
ACCOMMODATE THE OWNER'S NEEDS ARE REQUIRED.
4. REMOVE THE INDICATED FIRE PROTECTION ITEMS AS SHOWN
ON PLANS. THIS INCLUDES ALL HANGERS, STRAPS, AND
RELATED MATERIAL.
5. THE FIRE PROTECTION CONTRACTOR SHALL BE
RESPONSIBLE FOR CUTTING AND PATCHING OF EXISTING
CONSTRUCTION UNLESS OTHERWISE NOTED ON PLANS. NO
CUTTING OF STRUCTURAL MEMBERS OR STRUCTURE WHICH
WILL DETERIORATE THE INTEGRITY AND STRENGTH OF THE
BUILDING WILL BE ALLOWED WITHOUT THE WRITTEN
APPROVAL FROM THE STRUCTURAL ENGINEER.
6. PATCH AND REPAIR OPENINGS THROUGH WALLS AND
FLOORS WHERE PIPES WERE REMOVED TO MATCH EXISTING
AND TO MAINTAIN FIRE RATINGS.
7. CONTRACTOR SHALL VERIFY CLEARANCE REQUIREMENTS
AND INDICATE ROUTING OF NEW PIPING BEFORE
FABRICATION BEGINS AS RISES AND DROPS MAY BE
NECESSARY DUE TO EXISTING FIELD CONDITIONS.
GENERAL FIRE PROTECTION
DEMOLITION NOTES
2 HOUR FIRE/SMOKE RESISTANCE RATING
1 HOUR FIRE/SMOKE RESISTANCE RATING
2 HOUR FIRE RESISTANCE RATING
30 MINUTE SMOKE BARRIER
1 HOUR FIRE RESISTANCE RATING
SMOKE RESISTIVE HAZARDOUS ENCLOSURE
SMOKE AND FIRE WALL LEGEND
1S
REMARKSESCUT SIN #K FINISHTHREADMFG. TEMPMODEL
SPRINKLER LEGEND
TYPESYM. RESP
UPRIGHT R1425RELIABLE 155°Q.R. F1FR-56 --------BRASS5.61/2"
SIDEWALL R1435RELIABLE 155°Q.R. F1FR-56 --------BRASS5.61/2"
PENDENT R1414RELIABLE 155°Q.R. F1FR-56 SEMI-RECESSEDCHROME5.61/2"
DRY PENDENT R5714RELIABLE 155°Q.R. F3QR56 TWO-PIECECHROME5.61/2"
UPRIGHT R1325RELIABLE 155°S.R. F1-56 --------BRASS5.61/2"
S A
N
S T
O R
M
820 S. DAMEN AVENUE
CHICAGO, ILLINOIS 60612
312.569.8387
PROJECT LOCATION:
JESSE BROWN VA MEDICAL CENTER
PROJECT TITLE:
SPRINKLER CORRECTIONS
[MATOC] 537-16-102A
BUILDING NUMBERS:
01, 11, 30, 40, & 42
V U.S. Department of Veterans Affairs A
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions
31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins
Sprinkler Corrections
Jesse Brown VAMC
Chicago, IL
537-16-102A
Project Director
Revisions: Date:
Keyplan: Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions
31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins
Sprinkler Corrections
Jesse Brown VAMC
Chicago, IL
537-16-102A
Project Director
Revisions: Date:
Keyplan:
FP001
NOTES, SYMBOLS, AND
ABBREVIATIONS
08/30/2020
100% Complete and Final
Issued for 100% Complete and Final
Issued for 100% CD
08/30/2020
02/10/2020
B400
B440
CRAWL SPACE
OPEN TO
CROSS PIPE
UP
DN
STAIR
UP
UP
LOUVER
WINDOW
LOUVER
WINDOW
LOUVER
WINDOW
LOUVER
WINDOW
LOUVER
WINDOW
LOUVER
WINDOW
LOUVER
WINDOW
LOUVER
WINDOW
LOUVER
WINDOW
LOUVER
WINDOW
LOUVER
WINDOW
LOUVER
WINDOW
LOUVER
WINDOW
LOUVER
WINDOW
LOUVER
WINDOW
LOUVER
WINDOW
LOUVER
WINDOW
LOUVER
WINDOW
STAIR
UP
NO 5NO 2
LOUVER
WINDOW
LOUVER
WINDOW
LOUVER
WINDOW
DN
SVC
LOBBY
CB-1
CORRIDOR
CB-2
ELEVATOR
B409
B443
B441
MECH RM
MULTIPURPOSE RM
B456
SUPPLY RM
B452
EMS STORAGE
B451
ELEVATOR
PIT
P1
ELEVATOR
PIT
P2
ELEVATOR
PIT
P3
ELEVATOR
PIT
P4
ELEVATOR
S5
ELEVATOR
S6ELECTRICAL
STORAGE
B402
STAIR
NO 1
B401
B403
MECH/TANK RM
ELECTRICAL STORAGE
BACK FILL
BACK FILL
ELEVATOR
NO P7
2 2
B400
B440
CRAWL SPACE
OPEN TO
CROSS PIPE
UP
DN
STAIR
UP
UP
STAIR
UP
NO 5NO 2
DN
TS
TS
B01B
B01A NORTH
B
A
S
O U
T H
B
N
R
T H
B
U
T H
B
R
T H
B01B
B01A NORTH
N TS
UP
DN
UP
UP
UP
DN
R TS
R
TS
B01B
B01A NORTH
B
U
T H
B
R
T H
B
U
T H
B
R
T H
B01B
B01A NORTH
D0
A1
D0
A2
D0
A3
D0
A5
D0
A6
D0
A7
D0
A8
D0
A9
D0
B1
D0
B2
D0
B3
D0
A6
D0
B1
D0
B3
D0
B3
B01A FX100-N
BUILDING 01A
BASEMENT PLAN NORTH
08/30/2020
100% Complete and Final
Issued for 100% Complete and Final
Issued for 100% CD
08/30/2020
02/10/2020
B01
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions
31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins
Sprinkler Corrections
Jesse Brown VAMC
Chicago, IL
537-16-102A
Project Director
Revisions: Date:
1/8"=1'-0"
4' 8'0 16'
Keyplan:
N
S
FIRE PROTECTION KEYED NOTES:
**THE NOTES PROVIDED HERE CORRESPOND TO THE ASSOCIATED PHOTOS
GENERATED IN THE FIELD REPORT FOR THIS AREA. REFER TO PHOTOS FOR
OBSERVED DEFICIENCIES, DEFECTS, OMISSIONS, AND ERRORS OF THE
EXISTING SPRINKLER SYSTEM. 10-02-2019 BUILDING 1 LOWER LEVEL.
INCOMING FIRE SERVICE MAIN ELBOW SHALL BE REPLACED. (PHOTO 1)
REMOVE ZIP TIE BETWEEN SPRINKLER PIPE AND CONDUIT. PROVIDE
PROPER HANGER FOR INSTALLATION SUPPORT. (PHOTO 2)
EXISTING VALVES ON WATER SERVICE ARE RUSTED AND SHALL BE
REPLACED. PROVIDE NEW OS&Y VALVES AND RECONNECT TAMPER
SWITCHES. (PHOTO 3)
REPLACE ALL PIPING IN BASEMENT LEVEL MECHANICAL TANK ROOM
WITHIN BUBBLED AREA. CURRENT STEAM LEAK HAS CORRODED PIPING
AND FITTINGS TO DISREPAIR. PIPING AND FITTINGS ARE RUSTING AND
CONTINUAL CORROSION WILL LEAD TO FAILURE OF PIPING. REPLACE
EXISTING HEADS WITHIN BUBBLED AREA WITH INTERMEDIATE
TEMPERATURE HEADS WITH 212°F RATING. (PHOTOS 4 - 17, 23, & 24)
EXISTING PIPE PENETRATION THROUGH FIREWALL SHALL HAVE FIRE
SEALANT INSTALLED IN OPENING. (PHOTO 18)
PAINT PIPING TO ELEVATOR PIT SPRINKLERS RED TO MATCH ALL
SURROUNDING MECHANICAL ROOM PIPING. (PHOTOS 19, & 22)
REVISE PIPING IN CORRIDOR TO ELIMINATE CONFLICTS WITH OTHER TRADE
PIPING/CONDUIT. CURRENTLY A PIECE OF WOOD BEING USED TO
SEPARATE ITEMS. (PHOTO 20)
EXISTING VALVE IN CORRIDOR HAS NON-RISING STEM, DOESN'T HAVE LOCK
TO PREVENT CLOSING, DOESN'T HAVE TAMPER SWITCH OR ANY
SUPERVISORY DEVICE. INSTALL LOCK ON VALVE TO SECURE VALVE TO
PREVENT CLOSURE. LOCK SHALL MEET NFPA REQUIREMENTS (PHOTO 21)
EXISTING FIRE PUMP CONCRETE PAD, 30" X 72" X 10" TO BE DEMOLISHED.
RESURFACE REMAINING CONCRETE TO MATCH SURROUNDING AREA.
SPRINKLER HEAD MISSING FROM DOCUMENTS, ADDED FOR ACCURACY OF
PLANS.
PROVIDE ADDITIONAL SPRINKLER HEAD UNDERNEATH BASE OF STAIRS.
PROVIDE CONNECTION FROM BRANCHLINE SERVING HEADS IN STAIRWELL
CORRIDOR.
EXISTING 6" BUTTERFLY VALVE WITH TAMPER SWITCH TO FEED RISERS TO
REMAIN.
D0
A1
D0
A2
D0
A3
D0
A4
D0
A5
D0
A6
D0
A7
D0
A8
D0
A9
D0
B1
D0
B2
D0
B3
STAIR
UP
LOUVER
WINDOW
LOUVER
WINDOW
LOUVER
WINDOW
LOUVER
WINDOW
LOUVER
WINDOW
NO 2
STAIR
UP
NO 2
TS
F
L
F
L
F
L
B
U
T H
B
R
T H
B
U
T H
B
R
T H
N TS
UP
R
TS
F
L
F
L
F
L
F
L
F
L
F
L
B
U
T H
B
R
T H
B
U
T H
B
R
T H
D0
B3
D0
B3
B01A FX100-S
BUILDING 01A
BASEMENT PLAN SOUTH
08/30/2020
100% Complete and Final
Issued for 100% Complete and Final
Issued for 100% CD
08/30/2020
02/10/2020
B01
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions
31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins
Sprinkler Corrections
Jesse Brown VAMC
Chicago, IL
537-16-102A
Project Director
Revisions: Date:
1/8"=1'-0"
4' 8'0 16'
Keyplan:
N
S
FIRE PROTECTION KEYED NOTES:
**THE NOTES PROVIDED HERE CORRESPOND TO THE ASSOCIATED PHOTOS
GENERATED IN THE FIELD REPORT FOR THIS AREA. REFER TO PHOTOS FOR
OBSERVED DEFICIENCIES, DEFECTS, OMISSIONS, AND ERRORS OF THE
EXISTING SPRINKLER SYSTEM. 10-02-2019 BUILDING 1 LOWER LEVEL.
INCOMING FIRE SERVICE MAIN ELBOW SHALL BE REPLACED. (PHOTO 1)
REMOVE ZIP TIE BETWEEN SPRINKLER PIPE AND CONDUIT. PROVIDE
PROPER HANGER FOR INSTALLATION SUPPORT. (PHOTO 2)
EXISTING VALVES ON WATER SERVICE ARE RUSTED AND SHALL BE
REPLACED. PROVIDE NEW OS&Y VALVES AND RECONNECT TAMPER
SWITCHES. (PHOTO 3)
REPLACE ALL PIPING IN BASEMENT LEVEL MECHANICAL TANK ROOM
WITHIN BUBBLED AREA. CURRENT STEAM LEAK HAS CORRODED PIPING
AND FITTINGS TO DISREPAIR. PIPING AND FITTINGS ARE RUSTING AND
CONTINUAL CORROSION WILL LEAD TO FAILURE OF PIPING. (PHOTOS 4 - 17,
23, & 24)
EXISTING PIPE PENETRATION THROUGH FIREWALL SHALL HAVE FIRE
SEALANT INSTALLED IN OPENING. (PHOTO 18)
PAINT PIPING TO ELEVATOR PIT SPRINKLERS RED TO MATCH ALL
SURROUNDING MECHANICAL ROOM PIPING. (PHOTOS 19, & 22)
REVISE PIPING IN CORRIDOR TO ELIMINATE CONFLICTS WITH OTHER TRADE
PIPING/CONDUIT. CURRENTLY A PIECE OF WOOD BEING USED TO
SEPARATE ITEMS. (PHOTO 20)
EXISTING VALVE IN CORRIDOR HAS NON-RISING STEM, DOES NOT HAVE
LOCK TO PREVENT CLOSING, DOES NOT HAVE TAMPER SWITCH OR ANY
SUPERVISORY DEVICE. VALVE SHALL HAVE LOCK TO PREVENT CLOSURE.
(PHOTO 21)
EXISTING FIRE PUMP CONCRETE PAD, 30" x 72" x 10" TO BE DEMOLISHED.
RESURFACE REMAINING CONCRETE TO MATCH SURROUNDING AREA.
SPRINKLER HEAD MISSING FROM DOCUMENTS, ADDED FOR ACCURACY OF
PLANS.
PROVIDE ADDITIONAL SPRINKLER HEAD UNDERNEATH BASE OF STAIRS.
PROVIDE CONNECTION FROM BRANCHLINE SERVING HEADS IN STAIRWELL
CORRIDOR.
EXISTING 6" BUTTERFLY VALVE WITH TAMPER SWITCH TO FEED RISERS TO
REMAIN.
D0
A1
D0
A2
D0
A3
D0
A4
D0
A5
D0
A6
D0
A7
D0
A8
D0
A9
D0
B1
D0
B2
OVER HEAD DOOR
FIRE
CLOSET
RADIOLOGY
SCHEDULING
TOILET
1491A
ON CALL
1491B
STAIR
EMS LINEN RM
ELEVATOR
MECH
ELEVATOR
FOYER
MORGUE
ELEVATOR
STAIR
NO 5 TELECOMMUNICATION RM
14T4
ELECTRICAL
14E7
TOILET
1499A
DOCTOR
OFFICE
SECRET
OFFICE
STORAGE
COMP AND
PENS STAFF
GAS CYLINDER
STORAGE
VESTIBULE
1499B
NO 5A 1
4.1
3.8
NEW
COLUMN
LINE
1.1
B01B
B01A NORTH
D1
B2
D1
B3
D1
B4
D1
B5
1S
S
S
S
S
S
D1
A3
D1
A3
D1
B6
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions
31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins
Sprinkler Corrections
Jesse Brown VAMC
Chicago, IL
537-16-102A
Project Director
Revisions: Date:
1/8"=1'-0"
4' 8'0 16'
Keyplan:
N
S B01A FX101-N
BUILDING 01A
FIRST FLOOR PLAN NORTH
08/30/2020
100% Complete and Final
Issued for 100% Complete and Final
Issued for 100% CD
08/30/2020
02/10/2020
B01
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions
31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins
Sprinkler Corrections
Jesse Brown VAMC
Chicago, IL
537-16-102A
Project Director
Revisions: Date:
1/8"=1'-0"
4' 8'0 16'
Keyplan:
N
S
BUILDING 1A 1ST FLOOR PLAN NORTH
1/8" = 1'-0"
FIRE PROTECTION KEYED NOTES:
**THE NOTES PROVIDED HERE CORRESPOND TO THE ASSOCIATED PHOTOS
GENERATED IN THE FIELD REPORT FOR THIS AREA. REFER TO PHOTOS FOR
OBSERVED DEFICIENCIES, DEFECTS, OMISSIONS, AND ERRORS OF THE EXISTING
SPRINKLER SYSTEM. 01-15-2020 & 01-17-2020 FULL CAMPUS 1ST FLOOR.
SPRINKLER HEAD INSTALLED TO FAR FROM BACK WALL, >9'-0". RELOCATE
SPRINKLER ONE TILE CLOSER TO WALL (2'-0") TO MEET CODE SPACING
REQUIREMENTS. (PHOTO 26)
SPRINKLER PIPING RUSTING - 4 - 6 FOOT LENGTH. REPLACE WITH NEW
(PHOTOS 33, 34 & 37)
SPRINKLER FITTING RUSTED. REPLACE WITH NEW.
(PHOTOS 35, 36, 44, 46, 47, 48, 55)
DRAIN PAN SUPPORTED BY SPRINKLER PIPING. PROVIDE SEPARATE
HANGER SYSTEM FOR DRAIN PAN SYSTEM (2 LINES) (PHOTO 38)
HANGER ROD BENT. REPLACE WITH NEW
(PHOTO 39)
SPRINKLER HEADS NOT PROVIDED UNDER DUCTWORK. INSTALL
SPRINKLER UNDER DUCTWORK (PHOTO 40)
SPRINKLER PROTECTION IN GARAGE NOT PROTECTED WITH DRY PIPE
VALVE. INSTALL NEW DRY PIPE VALVE. DRAIN SYSTEM AND RECONNECT
GARAGE SYSTEM TO DRY PIPE VALVE. (PHOTO 41)
SPRINKLER HEADS IN GARAGE ARE BLOCKED BY CEILING ELEVATION
CHANGE. REVISE SPRINKLER LAYOUT TO PROVIDE PROPER COVERAGE.
(PHOTO 42)
SPRINKLER COVERAGE IN GARAGE DOES NOT COVER UNDER ROLL UP
DOORS. PROVIDE SIDEWALL HEADS FOR PROTECTION UNDER DOORS.
ENSURE HEADS WILL NOT BE HIT BY AMBULANCE (PHOTO 43)
EXPOSED SPRINKLER PIPING IN TELECOM CLOSET CANNOT BE CPVC.
REPLACE PIPING WITH METAL. SPRINKLER HEAD NOT INSTALLED WITHIN 8"
OF DECK. INSTALL HEAD CLOSER TO DECK. (PHOTO 45)
SPRINKLER HEAD RUSTED AND SURROUNDING CEILING HAS WATER
DAMAGE. REPLACE HEAD. REPLACE SPRINKLER HEAD WITH NEW. REMOVE
ENTIRE DRYWALL CEILING IN ROOM AND REPLACE WITH NEW. REVIEW
WITH BUILDING ENGINEERING ABOVE CEILING SPACE. (PHOTO 49)
SIDEWALL HEAD ON EXTERIOR OBSTRUCTED BY DRAIN LINE. RELOCATE
HEAD OR ADD HEAD ON OTHER SIDE OF PIPE. (PHOTO 50)
LOWER STAIRWELL TO EXTERIOR AND CRAWLSPACE DOES NOT HAVE
SPRINKLER PROTECTION. INSTALL NEW HEAD UNDER LANDING. (PHOTO 54)
CRAWLSPACE ACCESS AND SPACE DOES NOT HAVE SPRINKLER
PROTECTION. PROVIDE SIGNAGE ON ACCESS DOOR. "SPACE FOR SUB
BASEMENT MAINTENANCE ACCESS ONLY. NOT TO BE USED FOR STORAGE.
ACCESS NOT PERMITTED WITHOUT AUTHORIZATION FROM ENGINEERING."
CLEAR OUT ALL ITEMS WITHIN BASEMENT. (PHOTOS 56, 57, & 58)
EXISTING 2 1/2" BUTTERFLY VALVE WITH TAMPER SWITCH TO FEED FLOOR
SPRINKLER ZONE TO REMAIN.
(PHOTOS 27-32, 51-53, & 59-62)
D1
A1
D1
A2
D1
A3
D1
A4
D1
A5
D1
A6
D1
A7
D1
A8
D1
A9
D1
B1
D1
B2
D1
B3
D1
B4
D1
B5
D1
B6
ROLLING SHUTTER ROLLING SHUTTER
OVER HEAD DOOR
FEC
PNEUMATIC
TUBE
FAC
FAC
TEL
FIRE
HOSE
11E1
ELEVATOR
NO S5
ELEVATOR
NO S6
ELEVATOR
NO P1
ELEVATOR
NO P2
CORRIDOR
C1404
TOILET
1491A
CORRIDOR
C1405
CORRIDOR
C1407
CORRIDOR
C1406
CORRIDOR
C1409
CORRIDOR
C1445
WAITING RM
WOMENS
TOILET
MENS TOILET
HEALTH VET
CO-ORDR
CREDIT
UNION
FIRE
CONTROL
PATIENT
ADVOCATE
OFFICE
OPTICAL
DISPENSARY
1410A
TRIAGE
TRIAGE
ELECTRICAL
SWITCH RM
14E2
TRIAGE
ED PHYSICIAN
1414ELECTRICAL
14E1
ADDICTION
CONSULT
RM
RECEPTION
CONSULT
RM
PATIENT
ADVOCATE
1459A
E D OFFICE
ELECTRICAL
14E3
DECENDENT
AFFAIRS
CONSULT
RM
HAC
TOILET
1446 TEL
14T1
VESTIBULE/STAIR
STAIR
NO 2
PAC
CO-ORDR
OFFICE
CHIEF
CONSULT
RM
CONSULT
RM
CONSULT
RM
EMS
HOUSE
KEEPING
ELEVATOR
NO P7
ELEVATOR
NO P8
TEL
CLOSET
14T2
14E4
STAIR
NO 1
ELEVATOR
NO P3
ELEVATOR
NO P4
NURSE STATION EMERGENCY RM
EQUIP STORAGE
LOUNGE
ELECTRICAL
14E6
COMM
14T3
BEREAVEMENT
RM
1475A
SOILED
UTILITY
EXAM RM-7
1470G
EXAM RM-6
1470F
EXAM RM-5
1470E
EXAM RM-4
1470D
EXAM RM-3
1470C
EXAM RM-2
1470B
E D MGR
CFD SUPPLY
EXAM RM-1
1470A
ER HALLWAY
TRAVEL PAY
STORAGE
RECEPTION AND
ADMISSION
AMBULATORY
CARE SUPV
OFFICE
CHIEF
AMBULATORY
CORRIDOR
C1411
MANAGER
EMS STORAGE
1431A
ER STORAGE
1431B
TRIAGE
E D ATTENDING
TRIAGE
MEDICAL
SUPPORT
SUPERV
1431C
VAM NURSE
MNGR.
TOILET
VESTIBULE
C1408
GARAGE
LIFT
EQUIP.
CLEAN
SUPPLY
CLEAN
LINEN
TOILET
NEGATIVE
PRESSURE
RM
EXAM RM-15
1470R
EXAM RM-14
1470Q
EXAM RM-13
1470P
EXAM RM-12
1470N
EXAM RM-11
1470M
PARAMEDIC RM
1470L
MEDS
1470H
EXAM RM-8
1470J
EXAM RM-9
1470K
ON CALL
1491B
STAIR
DONATED
CLOTHING
1508 EMS LINEN RM
PHARMACY IV
STORAGE
VESTIBULE
CORRIDOR
C1505
CORRIDOR
C1504
ENTRANCE/LOBBY
C1103
ELECTRICAL
1541B
CLEAN
SUPPLY
CORRIDOR
C1502
HAC
CORRIDOR
C1503
GAS CYLINDER
STORAGE
CORRIDOR
CORRIDOR
ELECTRICAL
CLOSET
OPTICAL
WAITING RM
CORRIDOR
C1505
NO 5A
1436A
NO 2
1410B
C1404
C1404
ELECTRIC
CLOSET
14E5
TOILET
B01B
B01A NORTH
B
U
T H
B
R
T H
B
U
T H
B
R
T H
B11B
B30
D1
A7
D1
A8
D1
B1
D1
B2
S
1S
2 2 2 2 2
2 2 2 2 2 2 2
S
S
1S
S
1S
S
1S
1S
S
S
S
S
S
1S
S
S
S
D1
A8
D1
A8
D1
A8
D1
A9
D1
A9
D1
A3
D1
A3
D1
A3
D1
A3
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions
31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins
Sprinkler Corrections
Jesse Brown VAMC
Chicago, IL
537-16-102A
Project Director
Revisions: Date:
1/8"=1'-0"
4' 8'0 16'
Keyplan:
N
S B01A FX101-S
BUILDING 01A
FIRST FLOOR PLAN SOUTH
08/30/2020
100% Complete and Final
Issued for 100% Complete and Final
Issued for 100% CD
08/30/2020
02/10/2020
B01
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions
31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins
Sprinkler Corrections
Jesse Brown VAMC
Chicago, IL
537-16-102A
Project Director
Revisions: Date:
1/8"=1'-0"
4' 8'0 16'
Keyplan:
N
S
BUILDING 1A 1ST FLOOR PLAN SOUTH
1/8" = 1'-0"
FIRE PROTECTION KEYED NOTES:
**THE NOTES PROVIDED HERE CORRESPOND TO THE ASSOCIATED PHOTOS
GENERATED IN THE FIELD REPORT FOR THIS AREA. REFER TO PHOTOS FOR
OBSERVED DEFICIENCIES, DEFECTS, OMISSIONS, AND ERRORS OF THE EXISTING
SPRINKLER SYSTEM. 01-15-2020 & 01-17-2020 FULL CAMPUS 1ST FLOOR.
SPRINKLER HEAD INSTALLED TO FAR FROM BACK WALL, >9'-0". RELOCATE
SPRINKLER ONE TILE CLOSER TO WALL (2'-0") TO MEET CODE SPACING
REQUIREMENTS. (PHOTO 26)
SPRINKLER PIPING RUSTING - 4 - 6 FOOT LENGTH. REPLACE WITH NEW
(PHOTOS 33, 34 & 37)
SPRINKLER FITTING RUSTED. REPLACE WITH NEW.
(PHOTOS 35, 36, 44, 46, 47, 48, 55)
DRAIN PAN SUPPORTED BY SPRINKLER PIPING. PROVIDE SEPARATE
HANGER SYSTEM FOR DRAIN PAN SYSTEM (2 LINES) (PHOTO 38)
HANGER ROD BENT. REPLACE WITH NEW
(PHOTO 39)
SPRINKLER HEADS NOT PROVIDED UNDER DUCTWORK. INSTALL
SPRINKLER UNDER DUCTWORK (PHOTO 40)
SPRINKLER PROTECTION IN GARAGE NOT PROTECTED WITH DRY PIPE
VALVE. INSTALL NEW DRY PIPE VALVE. DRAIN SYSTEM AND RECONNECT
GARAGE SYSTEM TO DRY PIPE VALVE. (PHOTO 41)
SPRINKLER HEADS IN GARAGE ARE BLOCKED BY CEILING ELEVATION
CHANGE. REVISE SPRINKLER LAYOUT TO PROVIDE PROPER COVERAGE.
(PHOTO 42)
SPRINKLER COVERAGE IN GARAGE DOES NOT COVER UNDER ROLL UP
DOORS. PROVIDE SIDEWALL HEADS FOR PROTECTION UNDER DOORS.
ENSURE HEADS WILL NOT BE HIT BY AMBULANCE (PHOTO 43)
EXPOSED SPRINKLER PIPING IN TELECOM CLOSET CANNOT BE CPVC.
REPLACE PIPING WITH METAL. SPRINKLER HEAD NOT INSTALLED WITHIN 8"
OF DECK. INSTALL HEAD CLOSER TO DECK. (PHOTO 45)
SPRINKLER HEAD RUSTED AND SURROUNDING CEILING HAS WATER
DAMAGE. REPLACE HEAD. REPLACE SPRINKLER HEAD WITH NEW. REMOVE
ENTIRE DRYWALL CEILING IN ROOM AND REPLACE WITH NEW. REVIEW
WITH BUILDING ENGINEERING ABOVE CEILING SPACE. (PHOTO 49)
SIDEWALL HEAD ON EXTERIOR OBSTRUCTED BY DRAIN LINE. RELOCATE
HEAD OR ADD HEAD ON OTHER SIDE OF PIPE. (PHOTO 50)
LOWER STAIRWELL TO EXTERIOR AND CRAWLSPACE DOES NOT HAVE
SPRINKLER PROTECTION. INSTALL NEW HEAD UNDER LANDING. (PHOTO 54)
CRAWLSPACE ACCESS AND SPACE DOES NOT HAVE SPRINKLER
PROTECTION. PROVIDE SIGNAGE ON ACCESS DOOR. "SPACE FOR SUB
BASEMENT MAINTENANCE ACCESS ONLY. NOT TO BE USED FOR STORAGE.
ACCESS NOT PERMITTED WITHOUT AUTHORIZATION FROM ENGINEERING."
CLEAR OUT ALL ITEMS WITHIN BASEMENT. (PHOTOS 56, 57, & 58)
EXISTING 2 1/2" BUTTERFLY VALVE WITH TAMPER SWITCH TO FEED FLOOR
SPRINKLER ZONE TO REMAIN.
(PHOTOS 27-32, 51-53, & 59-62)
D1
A1
D1
A2
D1
A3
D1
A4
D1
A5
D1
A6
D1
A7
D1
A8
D1
A9
D1
B1
D1
B2
D1
B3
D1
B4
D1
B5
NUCLEAR MEDICINE
A C
CHIEF OF STAFF
B
TV
RAMP DN
ROOF
TEL
24E2 STORAGE
FAC
2479A
ELECTRICAL
CLOSET
24E3
COAT CLOSET
2438C
STORAGE
2438A
TOILET
2438B
STORAGE
2440A
2447A
CONNECTING
CORRIDOR
C2307
CORRIDOR
C2401
ELEVATOR
ELEVATOR
CORRIDOR
C2409
CORRIDOR
C2404
CORRIDOR
C2408
STORAGE
AUTOPSY
AREA
ELEVATOR
NO P4
ELEVATOR
NO P3
ELEVATOR
NO P2
ELEVATOR
NO P1
SOILED
UTILITY
TOILET/
SHOWER
2497A
MORGUE CLEAN UTILITY
REFR
2477A
MECH SPACE
VOLUNTARY
STORAGE
VTS FLEET OPER
2449A
SUPV
OFFICE
2449B
ELEVATOR
NO P7
ELEVATOR
NO P8
PATIENT
ADVOCATE OFFICE
CORRIDOR
C2405
CONFERENCE RM
CPP AND
RESOURCE
TELEPHONE
CLOSET
24T1
STAIR
NO 1
MENS TOILET
STAIR
NO 2
STAFF
OFFICE
ASST TO
DIRECTOR
AUDITORIUM
ELECTRICAL
24E6
CORRIDOR
C2406
STAFF
ATTORNEY
PROGRAM
ANALYST
SECY STAFF
OFFICE
COS
OFFICE
AD OFFICE
ACOS CLINIC
AFFAIRS
OFFICE
STORAGE
BREAK
RM
WOMENS
TOILET
OFFICE
STORAGE
2446D
LOBBY
STRATEGIC
PLANNER
ELECTRICAL
RECEPTION
2444A VESTIBULE
MENS TOILET
STORAGE
2446A
WOMENS TOILET
UNISEX
TOILET
KITCHEN
2446B
CORRIDOR
C2402
STAIR
CORRIDOR
C2403
MECH SPACE
ELEVATOR
FAMILY VIEWING
TOILET
STORAGE
2492A
STAIR
NO 5
ELEVATOR
LAB
INJECTION
RM
PROCESSING
RM
ELECTRICAL
24E5
NUCLEAR MEDICINE
SCANNING AREA
TREATMENT RM
CHIEF OF STAFF
NURSE
EXECUTIVE
STORAGE
AND EQUIP
2446C
DRESSING
RM
2462APIV
PIV
PIV
VISUAL
CO-ORDR
TOILET
2474A
LOW AND
BLIND VISION
TREATMENT RM
STRESS LAB
WAITING
INJECTION RM
NUCLEAR
MED
RECEPTION
HAC
FILE RM
STAFF
PHYSICIAN
SECTION
CHIEF
BONE DENSITY
PROCEDURE RM
OPERATION
MANAGER
STAFF
OFFICE
M-1
NO 5A
2446H
2446F
2446G
WALL PARTITION CLOSETWALL PARTITION CLOSET
FIRE
CLOSET
FIRE
CLOSET
CLEAN
UTILITY
ROOF
ROOF
ELECTRICAL
CLOSET
24E4
B
A
S
O U
T H
B
A
N
O R
T H
B
A
S
O U
T H
B
A
N
O R
T H
B01B
B01A NORTH
D2
A4
D2
A5
D2
A6
D2
A7
D2
A8
D2
A9
D2
B1
D2
B2
D2
B3
D2
C5
D2
C1
D2
C1
D2
C1
D2
A3
D2
A3
D2
C2
D2 c3
D2
C4
D2
C2
D2
C9
D2
D1
C7
D2
OFFICE OF THE DIRECTOR A-120
24E2
STORAGE
ASSISTANT
DIRECTOR
CORRIDOR
C2407
MENS TOILET
2415TEL
STAIR
NO 2
DIRECTOR
OFFICE
TOILET
2413B
STORAGE
2413A
ELECTRICAL
24E1
SECRET
AREA
LOUNGE /
KITCHEN
NORTH PENT HOUSE
BUILDING 30
ASSOCIATE
DIRECTOR
SECRET
SECRET
PUBLIC
AFFAIRS
STAFF
OFFICE
FIRE
CLOSET
ASSISTANT
DIRECTOR
B
U
T H
B
R
T H
B
U
T H
B
R
T H
D2
A1
D2
A2
D2
C1
D2
C2
D2 c3
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions
31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins
Sprinkler Corrections
Jesse Brown VAMC
Chicago, IL
537-16-102A
Project Director
Revisions: Date:
1/8"=1'-0"
4' 8'0 16'
Keyplan:
N
S B01A FX102
BUILDING 01A
SECOND FLOOR PLAN
08/30/2020
100% Complete and Final
Issued for 100% Complete and Final
Issued for 100% CD
08/30/2020
02/10/2020
B01
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions
31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins
Sprinkler Corrections
Jesse Brown VAMC
Chicago, IL
537-16-102A
Project Director
Revisions: Date:
1/8"=1'-0"
4' 8'0 16'
Keyplan:
N
S
FIRE PROTECTION KEYED NOTES:
**THE NOTES PROVIDED HERE CORRESPOND TO THE ASSOCIATED PHOTOS
GENERATED IN THE FIELD REPORT FOR THIS AREA. REFER TO PHOTOS FOR
OBSERVED DEFICIENCIES, DEFECTS, OMISSIONS, AND ERRORS OF THE EXISTING
SPRINKLER SYSTEM. 10-17/18-2019 BUILDING 1 2ND FLOOR & 01-07-2020 FULL
CAMPUS MISSED ROOMS
EXISTING PIPE SLEEVE IS NOT INSERTED INTO WALL CAVITY. REMOVE
PIPE SLEEVE OR INSERT INTO WALL AND FIRE SEAL OPENING. (PHOTO 5)
REPLACE PIPING WITH CORROSION - OUTSIDE ROOM 2444.
(PHOTO 7)
REPLACE THINWALL PIPING WITH CPVC OR SCHEDULE 40 STEEL .
(PHOTOS 8, 22, 35 & 37)
EXIT DOOR FROM ASSEMBLY SPACE BLOCKED. REMOVE ITEMS
BLOCKING EXIT. (PHOTOS 9 & 10)
ADD SPRINKLER PROTECTION AT TOP OF STAIRWELL
(PHOTO 11)
REMOVE STORAGE FROM STAIRWELL ADA SPACE.
(PHOTO 12)
LEAKING CHEMICAL WASTE PIPING ABOVE CEILING. REPLACE DAMAGED
SPRINKLER FITTINGS FROM CHEMICAL WASTE LEAK. (PHOTOS 13 & 14)
REPLACE RUSTED FITTINGS AND PIPING.
(PHOTOS 15 & 16)
REMOVE IMPROPER FIRE SEALANT AND REPLACE WITH NEW. PROVIDE UL
LISTED FIRE SEAL ASSEMBLY. (PHOTO 21)
RELOCATE SPRINKLER HEAD TO BE AWAY FROM LIGHT OBSTRUCTION.
(PHOTO 24)
RELOCATE SPRINKLER HEAD BEING BLOCKED BY HEATER ON WALL.
(PHOTO 25)
REMOVE STORAGE ITEMS TO ALLOW PROPER SPRINKLER CLEARANCES.
MINIMUM 18" FROM DEFLECTOR REQUIRED. (PHOTOS 32 & 33)
SANITARY PIPING LEAKING ABOVE CEILING. REPLACE DAMAGED PIPE
WITH NEW. (PHOTO 34)
REPLACE RUSTED FITTINGS AND PIPING.
(PHOTO 36)
ADD ADDITIONAL HANGER ON CPVC PIPING. EXISTING HANGERS ARE
LOCATED TOO FAR APART. 9 FOOT MAX BETWEEN HANGERS FOR 2 1/2"
PIPING. (PHOTO 41)
REMOVE HANGER ON SPRINKLER PIPING FOR OTHER TRADE EQUIPMENT.
ATTACH LOOSE SUPPORT TO STRUCTURE. (PHOTO 42)
REMOVE TAPE AND PLASTIC AND REPAIR DAMAGED PIPING.
(PHOTO 43)
REMOVE FIRE SEALANT FROM PIPING.
(PHOTO 44)
EXISTING 2 1/2" BUTTERFLY VALVE WITH TAMPER SWITCH TO FEED
FLOOR SPRINKLER ZONE TO REMAIN.
(PHOTOS 1-3. 17-20, 26-30, 38-40, 45, & 46)
TYPICAL TRANSITION FROM STEEL PIPING TO CPVC.
(PHOTOS 4 & 31)
TYPICAL INSTALLATION OF FLEXIBLE DROP SPRINKLER
NO WORK REQUIRED. (PHOTO 6)
FIRE SEALANT INSTALLATION TYPICAL FOR STEAL PIPING
(PHOTO 23)
UNKNOWN LEAK ABOVE CEILING. AIR OR GAS WITNESSED ABOVE
CEILING. PLUG OR SEAL LEAKING PIPE. COORDINATE WITH ENGINEERING.
DEMOLISH UPRIGHT SPRINKLER HEAD ABOVE CEILING.
ADDITIONAL SPRINKLERS REQUIRED IN AREA. PROVIDE HEADS UNDER
SOFFIT ALONG EAST WALL WHERE NO CURRENT HEADS EXIST. ADD 5
NEW HEADS.
ADD SPRINKLER PIPING HANGERS. APPROXIMATELY 20'-0" APART.
PIPE EXTENSION FROM ELBOW TO SPRINKLER IS TOO SMALL. PIPE
REQUIRED TO BE MINIMUM OF 1" DIAMETER. REPLACE WITH PROPER
PIPING. (PHOTO 1)
SPRINKLER AND CEILING HAS WATER SPOTS AND DISCOLORATION.
REPLACE SPRINKLER HEAD AND REMOVE CEILING AND REPLACE WITH
NEW. (PHOTO 2)
BUILDING 1A 2ND FLOOR PLAN NORTH
1/8" = 1'-0"
BUILDING 1A 2ND FLOOR PLAN SOUTH
1/8" = 1'-0"
D2
A1
D2
A2
D2
A3
D2
A4
D2
A5
D2
A6
D2
A7
D2
A8
D2
A9
D2
B1
D2
B2
D2
B3
D2
B4
D2
B5
D2
B6
D2
B7
D2
B8
D2
B9
D2
C1
D2
C6
D2
C7
D2
C8
D2
C2
D2
C3
D2
C4
D2
C5
D2
C9
D2
CARDIOLOGY
DIALYSIS
DIALYSIS
OFFICE
HAC
TOILET
3426A
UNISEX
TOILET
3475A
SOILED
UTILITY
ELECTRICAL CLOSET
3487TOILET
FAC
ELECTRICAL
34E4
BACKUP
GENERATOR RM
3472C
STORAGE
3472B
STORAGE
3455A
ELECTRICAL
3495A
ELECTRICAL
3497A
VESTIBULE/
CHASE
LINEN CHUTE
ELECTRICAL
34E2
TOILET
3443A
VESTIBULE
3439ASUPPLY CLOSET
TOILET
3424A
TOILET
3428A
TOILET
3432A
STORAGE
CLOSET
3434A
TOILET
3429A
TOILET
3427A
MENS
SHOWER
3425A
STORAGE
3485A
FAC
TOILET
3439B
FAC
3447A
CLOSET
CORRIDOR
C3401
NUTRITION AND FOOD
KITCHEN
CORRIDOR
C3402
CORRIDOR
C3404
CORRIDOR
C3403
CORRIDOR
C3406
ELEVATOR LOBBY
ELEVATOR
ELEVATOR
ELEVATOR
P-4
FOOD SVC
AND SUPV
ELEVATOR
P-3
ELEVATOR
P-2
ELEVATOR
P-1
HAC
HAC
OXYGEN
TANKS
DRESSING
ROOM
3475B
STORAGE
3475C LOCKER ROOM
DOCTORS
OFFICE
STAIR
NO 5
RESIDENT
GROUP
DOCTORS
OFFICE
DOCTORS
OFFICE
CHIEF
ENT
DOCTORS
OFFICE
DOCTORS
OFFICE
3494A
DOCTORS
OFFICE
RESIDENT
COORD.
DOCTORS
OFFICE
3488SURGERY STAFF
SECRETARY/
COPIER
HAC
BREAK ROOM
OFFICE
OFFICE
STORAGE
MECH RM
3472A
EQUIPMENT
STORAGE
LAB
MECH RM
3466A
SUPPLY RM
RECEPTION
3461CHIEF OFFICE
3460TANK RM
3454A
STORAGE
3454BDIALYSIS
STORAGE
CARDIO
STORAGE
NON
VA MED
CARE
DIALYSIS RM
DIALYSIS
EQUIPMENT
FILE
STORAGE
SPD SUPPLY
DIALYSIS
SOLUTIONS-B
DIALYSIS
SOLUTIONS-A
STORAGE
STORAGE
WOMENS
TOILET
MECH RM
ELEVATOR
P-7
ELEVATOR
P-8
CLINIC NUTRITION
TEL
34T1
STAIR
NO 1
DIALYSIS
WAITING
NURSE
STATION
LOCKER
3439C
LOUNGE
CRASH CART
STORAGE
STAIR
NO 2
SOCIAL
WORK
NURSE
MGR
OXYGEN TANKS
IV RM
MENS TOILET
LEAD TECH
HEMO DIALYSIS
DIR OFFICE
CONSL MGR
MECH RM
S-5
S-6
CORRIDOR
3468A
ROOF
ROOF
ROOF
ROOF
ELECTRICAL
CLOSET
34E4
B01A NORTH
B
U
T H
B
R
T H
B
U
T H
B
R
T H
B01B
B01A NORTH
D3
A1
D3
A2
D3
A3
D3
A4
D3
A5
D3
A6
D3
A7
D3
A8
D3
A9
D3
B5
D3
C1
D3
B9
D3
B9
D3
B9
D3
C3
1 BED 1 BED
NURSE
HEART STATION
CARDIOLOGY
1 BED
STATION
SUPPLY CLOSET
MENS
SHOWER
3425A
ELECTRICAL CLOSET
34E1
FAC
3411 CLOSET
CORRIDOR
C3405
CRASH CART
STORAGE
OFFICE
CUBICLE
STAIR
NO 2
OFFICE
CUBICLE
SUPPLY
ANALYSIS
SPD
SUPERVISOR
SYSTEM
ANALYST
STORAGE
3406 DIALYSIS
RM
SOCIAL
WORK
NURSE
MGR
MENS TOILET
B
U
T H
B
R
T H
B
U
T H
B
R
T H
D3
B9
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions
31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins
Sprinkler Corrections
Jesse Brown VAMC
Chicago, IL
537-16-102A
Project Director
Revisions: Date:
1/8"=1'-0"
4' 8'0 16'
Keyplan:
N
S B01A FX103
BUILDING 01A
THIRD FLOOR PLAN
08/30/2020
100% Complete and Final
Issued for 100% Complete and Final
Issued for 100% CD
08/30/2020
02/10/2020
B01
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions
31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins
Sprinkler Corrections
Jesse Brown VAMC
Chicago, IL
537-16-102A
Project Director
Revisions: Date:
1/8"=1'-0"
4' 8'0 16'
Keyplan:
N
S
BUILDING 1A 3RD FLOOR PLAN NORTH
1/8" = 1'-0"
BUILDING 1A 3RD FLOOR PLAN SOUTH
1/8" = 1'-0"
FIRE PROTECTION KEYED NOTES:
**THE NOTES PROVIDED HERE CORRESPOND TO THE ASSOCIATED PHOTOS
GENERATED IN THE FIELD REPORT FOR THIS AREA. REFER TO PHOTOS FOR
OBSERVED DEFICIENCIES, DEFECTS, OMISSIONS, AND ERRORS OF THE
EXISTING SPRINKLER SYSTEM. 10-18/21-2019 BUILDING 1 3RD FLOOR &
01-07-2020 FULL CAMPUS MISSED ROOMS.
REPLACE RUSTED HANGER ROD
(PHOTO 1)
REPLACE FIRESTOPPING ON PIPING THROUGH WALL PENETRATION.
REMOVE EXISTING AND REPLACE WITH NEW. (PHOTO 2)
RELOCATE SPRINKLER HEAD TO MINIMIZE OBSTRUCTION FROM
PIPING. (PHOTO 8)
REPLACE PIPING THAT IS RUSTED.
(PHOTO 9)
ADD ADDITIONAL SPRINKLER HEAD TO COVER AREA BLOCKED BY
COLUMN. (PHOTO 12)
ADD NEW SPRINKLER HEAD IN DRYWALL CEILING THAT DOES NOT
HAVE COMPLETE COVERAGE. (PHOTO 17)
REPLACE BURNT CPVC PIPING WITH NEW.
(PHOTO 18)
INSTALL NEW SPRINKLER HEAD IN CORRIDOR WHERE SPRINKLER
COVERAGE MISSING. (PHOTO 19)
ADD 7 NEW SPRINKLER HEADS UNDER DUCTWORK IN KITCHEN.
DUCTWORK GREATER THAN 48" WIDE REQUIRED TO HAVE SPRINKLER
PROTECTION UNDERNEATH. CONTRACTOR SHALL USE SIDEWALL
HEADS WITH HEAD GUARDS TO MAXIMIZE CLEARANCE TO FLOOR.
(PHOTO 20)
TYPICAL DRY PENDANT SPRINKLER HEAD DROP INTO COOLER.
VERIFY SPRINKLER LISTING TO ENSURE INSTALLATION IS CORRECT
WITH ADDITIONAL TEE FITTING PRIOR TO DRY PENDANT. (PHOTO 21)
REPLACE RUSTED DRY PENDANT SPRINKLER HEAD IN COOLER.
(PHOTOS 22, 23, & 24)
REMOVE SPRINKLER HEADS ABOVE DROP CEILING.
(PHOTO 25)
ACCESS PANEL INACCESSIBLE ABOVE DROP CEILING. PROVIDE
SIGNAGE ON CEILING TO IDENTIFY LOCATION OF ACCESS PANEL.
(PHOTO 26)
REMOVE SPRINKLER HEAD OBSTRUCTED BY PIPING. ADJACENT
SPRINKLER HEAD PROVIDES COVERAGE. (PHOTO 27)
TYPICAL TRANSITION BETWEEN STEEL PIPING AND CPVC. NO WORK
TO BE DONE. (PHOTO 28)
DEMOLISH SPRINKLER HEAD INSTALLED TOUCHING WALL IN
STAIRWELL. ADJACENT SPRINKLER HEAD LESS THAN 7'-6" FROM DOOR
AND WILL PROVIDE COVERAGE. (PHOTOS 32 & 33)
REPLACE RUSTED SPRINKLER HEAD IN FREEZER.
(PHOTOS 38 & 39)
EXISTING 2 1/2" BUTTERFLY VALVE WITH TAMPER SWITCH TO FEED
FLOOR SPRINKLER ZONE TO REMAIN.
(PHOTOS 3-7, 10-15, 29-31 & 34-37)
PROVIDE NEW SPRINKLER HEAD IN DROP DOWN SOFFIT. ADJACENT
SPRINKLERS DO NOT PROVIDE COMPLETE COVERAGE. (PHOTO 40)
ADD SPRINKLER PROTECTION IN HOOD.
(PHOTO 41)
DEFLECTOR ON HEAD BENT. REPLACE SPRINKLER. (PHOTO 3)
D3
A1
D3
A2
D3
A3
D3
A4
D3
A5
D3
A6
D3
A7
D3
A8
D3
A9
D3
B1
D3
B2
D3
B3
D3
B4
D3
B5
D3
B6
D3
B7
D3
B8
D3
B9
D3
C1
D3
C2
D3
C2
DN UP
FEC
DNUP
UP DN
PANORAMIC RM
ELECTRIC
CLOSET
44E5
MED
CLOSET
SOILED
SPD CART
HOLDING
TEL/DATA
44T2
CLEAN SUPPLY
CONTROL RM
BARIATRIC
TOILET
SOILED UTILITY
NITROUS TANK
STORAGE
VESTIBULE/CHASE
4507 LINEN CHUTE
ELECTRICAL
CLOSET
ELECTRICAL
44E2
CLOSET
4447A
OLD CLOSET
4496A
ELECTRIC/
FAC CLOSET
44E4
TREATMENT BAY
4418A
CORRIDOR
C4501
CORRIDOR
C4408
CORRIDOR
C4404
CORRIDOR
C4402
CORRIDOR
C4401
PATHOLOGY
RESIDENTS
NEUROLOGY
OFFICE
NURSE
OFFICE
STAFF LOUNGE
ELEVATOR
P-7
ELEVATOR
P-8
MOVE COORD
STORAGE
ELEVATOR
LOBBY
ELEVATOR
P-1
ELEVATOR
P-2
ELEVATOR
P-3
ELEVATOR
P-4
ELEVATOR
S-5
ELEVATOR
S-6
MED OFFICE
LOCKER
JANITOR
CLOSET
TOILET TOILET
TOILET TOILET
PATIENT
TOILET
SURGY
MGR
RECOVERY BAY
STAIR
NO 5
SURGY
TEAM RM
PATIENT
TOILET
OFFICE
MAXILLOFACIAL- 4 MAXILLOFACIAL-3
CONE BEAM
MAXILLOFACIAL-1
MAXILLOFACIAL-2
INSTRUMENT
PREP
ORAL SURGY RM
ORAL SURGY RM
CORRIDOR
C4403
OFFICE
ENDOSCOPY-2
ENDOSCOPY-1
STORAGE
CONSULT RM
PERIODONTAL-1
PERIODONTAL-2
INSTRUMENT
PREP
CLEAN
LINEN
MECH RM
RECEPTION / ADMISSION
4427A
WAITINGWAITING
TEL
44T1
STAIR
NO 1
CORRIDOR
C4405
CORRIDOR
C4406
ORAL SURGERY-2
INSTRUMENT
PREP
HYGIENIST
OFFICE PREP
ORAL SURGERY-1
TREATMENT BAY
MECH RM
OFFICE
OFFICE
INSTRUMENT
PREP
ORAL
SURGERY-3
OFFICE
STAIR
NO 2
TREATMENT BAY
ROOF
ROOF
ROOF
ROOF
ROOF
ELECTRICAL
CLOSET
44E3
CORRIDOR4427B
STORAGE
B
U
T H
B
R
T H
B
U
T H
B
R
T H
B01B
B01A NORTH
D4
B5
D4
B6
D4
B7
D4
B8
D4
B9
D4
C1
D4
C4
D4
C2
D4
C2
D4
C2
D4
B8
FEC
FEC
DN UP
PANORAMIC RM
ELECTRICAL
CLOSET
SOILED
SPD CART
HOLDING
4405A
STORAGE
4407A
CONTROL RM
ELECTRICAL
CLOSET
4417CORRIDOR
C4407
ORAL SURGERY-2
OFFICE
STAIR
NO 2
TREATMENT BAY
4407ALCOVE
TREATMENT BAY
HYGIENIST
STORAGE
RESIDENT
TEAM RM
MODEL
MAKING
CERAMICS
LAB
4401A
LAB
44E1
B
U
T H
B
R
T H
B
U
T H
B
R
T H
D4
B5
D4
B6
D4
C2
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions
31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins
Sprinkler Corrections
Jesse Brown VAMC
Chicago, IL
537-16-102A
Project Director
Revisions: Date:
1/8"=1'-0"
4' 8'0 16'
Keyplan:
N
S B01A FX104
BUILDING 01A
FOURTH FLOOR PLAN
08/30/2020
100% Complete and Final
Issued for 100% Complete and Final
Issued for 100% CD
08/30/2020
02/10/2020
B01
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions
31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins
Sprinkler Corrections
Jesse Brown VAMC
Chicago, IL
537-16-102A
Project Director
Revisions: Date:
1/8"=1'-0"
4' 8'0 16'
Keyplan:
N
S
BUILDING 1A 4TH FLOOR PLAN NORTH
1/8" = 1'-0"
BUILDING 1A 4TH FLOOR PLAN SOUTH
1/8" = 1'-0"
FIRE PROTECTION KEYED NOTES:
**THE NOTES PROVIDED HERE CORRESPOND TO THE ASSOCIATED PHOTOS
GENERATED IN THE FIELD REPORT FOR THIS AREA. REFER TO PHOTOS FOR
OBSERVED DEFICIENCIES, DEFECTS, OMISSIONS, AND ERRORS OF THE
EXISTING SPRINKLER SYSTEM. 10-21/22-2019 BUILDING 1 4TH FLOOR.
REMOVE WIRE FROM LIGHT ON SPRINKLER PIPING. ADD HANGER TO SUPPORT
WIRE AND SEPARATE FROM TOUCHING PIPING. WIRE STARTING TO CUT
GROOVE IN PLASTIC PIPING. (PHOTO 5)
CLEAN GREASE OFF PIPING. IF CORROSION PRESENT REPLACE PIPING.
(PHOTO 6)
UNFINISHED SPACE SPRINKLER HEAD TOO LOW FROM CEILING. RAISE
SPRINKLER HEAD UP TO WITHIN 12" OF DECK. (PHOTO 7)
SPRINKLER HEAD REQUIRED ABOVE AND BELOW UNFINISHED CEILING.
PROVIDE TWO HEADS FOR PROPER PROTECTION. (PHOTO 8)
REPLACE CORROSIVE STEEL PIPING.
(PHOTO 9)
CLEAN PIPING, IF CONSTRUCTION PLASTER, NO WORK REQUIRED. IF
CORROSION REPLACE PIPING. (PHOTO 10)
REPLACE RUSTED FITTINGS.
(PHOTO 11)
SPRINKLER PIPING RUNNING THROUGH DUCTWORK INSULATION. REMOVE
INSULATION AND CHECK PIPING. REPLACE IF RUSTED. REPAIR INSULATION
WITH SPRINKLER PIPING OUTSIDE. (PHOTO 15)
DRY PENDANT HEAD IN COOLER. CHECK LISTING IF TEE PRIOR TO DRY PIPE IS
PERMITTED. (PHOTO 16)
REPAIR CEILING TILE WHERE HOLE FOR SPRINKLER HEAD CUT TOO LARGE.
(PHOTO 17)
REMOVE ZIP TIE AND WIRE ATTACHED TO PIPE.
(PHOTO 18)
DAMAGED EXIT SIGN. ONLY ONE SIDE ILLUMINATED.
(PHOTO 25)
PROVIDE ADDITIONAL HEAD UNDER DUCTWORK.
(PHOTO 26)
DEMOLISH SPRINKLER HEAD ABOVE CEILING OVER FIRE HOSE VALVE CABINET.
(PHOTO 29)
ADJUST HANGER TO ENSURE BRACING IS PROPERLY INSTALLED TIGHT TO PIPE.
(PHOTO 30)
NEW CPVC PIPING ROUGHED-IN BUT NOT CONNECTED TO WATER SUPPLY.
(PHOTO 31)
REINSTALL REMOVED SPRINKLER HEAD. NOT ENOUGH COVERAGE IN ROOM.
(PHOTOS 32 & 33)
ADD ADDITIONAL SPRINKLER HEAD. HEAD TOO FAR FROM WALL.
(PHOTO 37)
REMOVE/RELOCATE MATTRESS STORAGE IN CORRIDOR. SPACING TO
SPRINKLER HEAD LESS THAN MINIMUM REQUIRED DISTANCE OF 18".
(PHOTO 38)
EXISTING 2 1/2" BUTTERFLY VALVE WITH TAMPER SWITCH TO FEED FLOOR
SPRINKLER ZONE TO REMAIN. (PHOTO 1-4, 12-14, 19-24, 27-28, & 34-36)
SPRINKLER HEAD SHOWN HERE NOT INSTALLED. INSTALL HEAD IN THIS
LOCATION.
MECHANICAL SPACE IS COLD, PULLING AIR FROM EXPOSED EXTERIOR. IF
UNCHECKED SPRINKLER HEADS IN SPACE WILL FREEZE WHEN OUTSIDE
TEMPERATURES DROP. ENGINEERING TO ACCESS HOW TO BLOCK EXTERIOR
AIR FROM SPACE. WORK OUTSIDE SPRINKLER SCOPE.
D4
A1
D4
A2
D4
A3
D4
A4
D4
A5
D4
A6
D4
A7
D4
A8
D4
A9
D4
B1
D4
B2
D4
B3
D4
B4
D4
B5
D4
B6
D4
B7
D4
B8
D4
B9
D4
C1
D4
C2
D4
C3
D4
C4
STORAGE
SUPPLY CLOSET
FIRE CLOSET
5447A
WOMENS
LOCKER
TOILET
5434A
TOILET
5430A
DRESSING
RM
DRESSING
RM
TOILET
5429A
TOILET
5425A
TOILET
5423A
SOILED
UTILITY
LOCKER
RM
CLEAN LINEN
TOILET
5424A
TOILET
5439A
TOILET
5433A
ELECTRICAL
PANEL
54E4SUPPLY CLOSET
ELECTRICAL
CLOSET
5412A
STORAGE
5496A
TELECOM
CLOSET
54E2
REGISTRATION
DESK
ELECTRICAL
CLOSET
54E5
CORRIDOR
C5406
CORRIDOR
C5401
CORRIDOR
C5402
CORRIDOR
C5403
CORRIDOR
C5404
CORRIDOR
5500C
MENS TOILET
GROUP RM
PROCEDURE RM
RESEARCH
OFFICE
MEDICINE
PREP
STAIR
NO 2
EQUIPMENT
STORAGE
EXAM RM
EXAM RM
DAY
SURGY
EXAM RM
PHARMACIST
OFFICE
TOILET
5435A
TOILET
5436A
OFFICE
PSYCHOLOGIST
EXAM RM
EXAM RM
NURSE
STATION
BREAK
RM
WAITING RM
LINEN
HAC
5440 PATIENT
EDUCATION
RM
CLEAN
SUPPLY
TOILET
WAITING AREA
OFFICE
DOCTOR
LOUNGE
HAC
5462 CLEAN LINEN
TOILET
TOILET
5458A
MENS
LOCKER
NURSE
STATION
TOILET
RECOVERY AREA
DRESSING
TOILET
STORAGE
TOILET
5482 PROCEDURE
RM-5
PROCEDURE
RM-4
SCOPE
REPROCESSING
CLEAN RM
PROCEDURE
RM-3
PROCEDURE
RM-2
SUPPLY
CLEANING RM
MECH
RM
5489PROCEDURE
RM-1
STAIR
NO 5
OFFICE
MED
ATTEND
NURSE
MGR
FELLOW
OFFICE
OFFICE
ENDO
OFFICE
ENDO
DIRECTOR
SPD
SUPPLIES
ELEVATOR
P-1
ELEVATOR
P-2
ELEVATOR
P-3
ELEVATOR
P-4
ELEVATOR
S-5
ELEVATOR
S-6
TEL
54T1
STAIR
NO 1
CHECK-IN
ELEVATOR
P-8
ELEVATOR
P-7
FIRE/ELECTRICAL CLOSET
5417A
SERVICE
ELEVATOR
ROOF
ROOF
ROOF
ROOF
ROOF
ELECTRICAL CLOSET
54E3
UNISEX TOILET
UNISEX TOILET
DRESS
RM
DRESS
RM
TOILET
STAFF LOCKER RM
TRAINING RM
FILE
CABINET
VESTIBULE/CHASE
TOILET
CORRIDOR
C5501
B
A
S
O U
T H
B
A
N
O R
T H
B
A
S
O U
T H
B
A
N
O R
T H
B01B
B01A NORTH
D5
A1
D5
A2
D5
A3
D5
A4
D5
A5
D5
A6
D5
A7
D5
A8
D5
A7
D5
A7
D5
A7
D5
B2
D5
B2
D5
B2
SICU SUPPLY CLOSET
UNISEX
TOILET
ELECTRICAL
CLOSET
54E1
DIRTY LINEN
5400B
CLEAN LINEN
5400A
TOILET
5423A
RECEPTION
AREA
CORRIDOR
C5405
RESEARCH
OFFICE
MEDICINE
PREP
STAIR
NO 2
TEAM RM
LOCKER
5412LOUNGE
TREATMENT BED-5
TREATMENT BED-4
TREATMENT BED-3
TREATMENT BED-2
TREATMENT BED-1
TOILET
5406A
WAITING
EQUIPMENT
STORAGE
EXAM RM
FIRE/ELECTRICAL CLOSET
B
U
T H
B
R
T H
B
U
T H
B
R
T H
D5
B2
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions
31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins
Sprinkler Corrections
Jesse Brown VAMC
Chicago, IL
537-16-102A
Project Director
Revisions: Date:
1/8"=1'-0"
4' 8'0 16'
Keyplan:
N
S B01A FX105
BUILDING 01A
FIFTH FLOOR PLAN
08/30/2020
100% Complete and Final
Issued for 100% Complete and Final
Issued for 100% CD
08/30/2020
02/10/2020
B01
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions
31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins
Sprinkler Corrections
Jesse Brown VAMC
Chicago, IL
537-16-102A
Project Director
Revisions: Date:
1/8"=1'-0"
4' 8'0 16'
Keyplan:
N
S
BUILDING 1A 5TH FLOOR PLAN NORTH
1/8" = 1'-0"
BUILDING 1A 5TH FLOOR PLAN SOUTH
1/8" = 1'-0"
FIRE PROTECTION KEYED NOTES:
**THE NOTES PROVIDED HERE CORRESPOND TO THE ASSOCIATED PHOTOS
GENERATED IN THE FIELD REPORT FOR THIS AREA. REFER TO PHOTOS FOR
OBSERVED DEFICIENCIES, DEFECTS, OMISSIONS, AND ERRORS OF THE
EXISTING SPRINKLER SYSTEM. 10-22-2019 BUILDING 1 5TH FLOOR.
ALUMINUM FOIL USED IN LIEU OF FIRE SEALANT. REMOVE AND INSTALL
FIRE SEALANT FOR PENETRATION. (PHOTO 1)
REPLACE HANGER AND CONNECT TO ROD ATTACHED TO DECK
(PHOTO 5)
REMOVE WIRING WRAPPED AROUND PIPING. REVISE WIRING TO AVOID
RUNNING ON PIPING. ADD HANGER TO SUPPORT WIRE. (PHOTO 6)
CORROSION ON SANITARY PIPING OVERHEAD SPRINKLER LINE.
REPLACE DAMAGED SANITARY PIPING. (PHOTO 10)
REPLACE RUSTED SPRINKLER ESCUTCHEON.
(PHOTO 11)
PROVIDE ADDITIONAL HANGERS ON SPRINKLER PIPING. PIPE SAGGING.
(PHOTO 12)
REPLACE BURNT FITTINGS AND PIPING WITHIN CORRIDOR. NUMBER OF
AREAS WHERE BURN MARKS NOTICED. (PHOTOS 13-17)
REPLACE VICTAULIC COUPLING AND REPLACE WITH CPVC.
(PHOTO 21)
ADD SPRINKLER HEAD ON OPPOSITE SIDE OF EXIT SIGN OR RELOCATE
SIGN SO NOT OBSTRUCTING SPRINKLER HEAD. (PHOTO 25)
REPAIR CEILING WHERE SPRINKLER PENETRATION LARGER THAN
SPRINKLER ESCUTCHEON AND OPENING VISIBLE. (PHOTO 27)
EXISTING 2 1/2" BUTTERFLY VALVE WITH TAMPER SWITCH TO FEED
FLOOR SPRINKLER ZONE TO REMAIN. (PHOTOS 2-4, 7-9, 18-20, 22-24 & 26)
D5
A1
D5
A2
D5
A3
D5
A4
D5
A5
D5
A6
D5
A7
D5
A8
D5
A9
D5
B1
D5
B2
SHOWER
AREA
LOCKER LOCKER
STORAGE
TOILET
6423A
SIMULATION LAB
SUPPLY
ATTENDING
SOIL ROOM
TOILET
6461A
TOILET
6457A
LINEN CHUTE
FAC
NURSE UNION
ELECTRICAL
64E4
TOILET
6471A
TOILET
6473A
TOILET
6477A
E E O
STORAGE
6466TOILET
6468A
TOILET
6470A
TOILET
6472A
TOILET
6476A
TOILET
6422A
TOILET
6424A
TOILET
6426A
TOILET
6430A
ELECTRICAL
CLOSET
64E1
SUPPLY
TOILET
6425A
TOILET
6427A
TOILET
6431A
ELECTRICAL
CLOSET
64E2
TOILET
6439A
TOILET
6435A
FAC
PHONE
6453A
CLOSET
6497A
CORRIDOR
C6404
GENERAL
FOREMAN EMS
OFFICE
EMS SUPV
OFFICE
ELEVATOR
P-1
ELEVATOR
P-4
ELEVATOR
P-3
ELEVATOR
P-2
ELEVATOR
ELEVATOR
ELEVATOR
LOBBY
NURSE RECRUITER
ELEVATOR
P-7
ELEVATOR
P-8
CHIEF UROLOGY
OFFICE
TEL
64T1
6469A
CORRIDOR
C6402
STORAGE
CORRIDOR
C6403 CORRIDOR
C6401
STAIR
NO 1
NURSE
OFFICE
SOCIAL
WORKER
OFFICE
RECEPTION
RECEPTION
STAIR
NO 2
OFFICE
OFFICE
6434A
STORAGE
VACANT
6482STORAGE
SINK RM
FILE
STORAGE
STORAGE
TELE MOVE
PGM OFFICE
OFFICE
HOME
TELEHEALTH
STORAGE
6462A
SAFETY
STORAGE
STORAGE
UNISEX TOILET
STAIR
NO 5
UNION SEIU
6484 UNASSIGNED SPACE
PRIVACY/FOIA
NURSES UNION
6493 TEAM RM
CLINIC NUTRITION
EEO FILE
STORAGE
SUPPLY
EEO
ASSISTANT
ETHIC
CONSULTATION
CHAPLAIN OFFICE
CHAPLAIN OFFICE
LACTATION RM
CHAPLAIN OFFICE
E E O ASST
OFFICE
E E O PGM MGR
SOCIAL
WORKER
OFFICE
CLINICAL CHAPLAIN
OFFICE
CLINICAL
CHAPLAIN
OFFICE
HR
SPECIALIST
HAC
6460INFO SECURITY OFFICE
6412 GERIATRIC TEAM RM
ACS OFFICE
COMPLIANCE
OFFICE
ADMIN.
OFFICE
6444A
CUSTOMER
SVC
ORGAN
TRANSPLANT
CO-ORDR
CONFERENCE RM
FILE RM
KITCHEN
HAC
6436STORAGE
SUPPLY
OAA
OFFICE
SAFETY
SPECIALIST
SAFETY
MANAGER
INFO
SECURITY
OFFICE
HUD VASH
NURSE OFFICE
SOCIAL
WORKER
OFFICE
HUD VASH
HR
SPECIALIST
VASCULAR
OFFICE
SOCIAL
WORKER
OFFICE
SOCIAL WORKER
OFFICE
CLOSET
6435A
TOILET/SHOWER
6447A
S5
S6
SUPPLY
STORAGE
ROOF
ROOF
ROOF
ROOF
ROOF
ELECTRICAL CLOSET
64E3
B01B
B01A NORTH
B
U
T H
B
R
T H
B
U
T H
B
R
T H
B01B
B01A NORTH
D6
A1
D6
A2
D6
A9
SHOWER
AREA
STORAGE
TOILET
6423A
WATER
FOUNTAIN
FAC
STORAGE
STAIR
NO 2
STORAGE
UNISEX STAFF
TOILET
NURSE OFFICE
NURSE OFFICE
DOCTOR
OFFICE
NURSE OFFICE
6402 WAITING
INFO SECURITY OFFICE
SUPPLY
SAFETY
SPECIALIST
FIT
TESTING
6406A
B
U
T H
B
R
T H
B
U
T H
B
R
T H
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions
31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins
Sprinkler Corrections
Jesse Brown VAMC
Chicago, IL
537-16-102A
Project Director
Revisions: Date:
1/8"=1'-0"
4' 8'0 16'
Keyplan:
N
S B01A FX106
BUILDING 01A
SIXTH FLOOR PLAN
08/30/2020
100% Complete and Final
Issued for 100% Complete and Final
Issued for 100% CD
08/30/2020
02/10/2020
B01
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions
31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins
Sprinkler Corrections
Jesse Brown VAMC
Chicago, IL
537-16-102A
Project Director
Revisions: Date:
1/8"=1'-0"
4' 8'0 16'
Keyplan:
N
S
BUILDING 1A 6TH FLOOR PLAN NORTH
1/8" = 1'-0"
BUILDING 1A 6TH FLOOR PLAN SOUTH
1/8" = 1'-0"
FIRE PROTECTION KEYED NOTES:
**THE NOTES PROVIDED HERE CORRESPOND TO THE ASSOCIATED PHOTOS
GENERATED IN THE FIELD REPORT FOR THIS AREA. REFER TO PHOTOS FOR
OBSERVED DEFICIENCIES, DEFECTS, OMISSIONS, AND ERRORS OF THE
EXISTING SPRINKLER SYSTEM. 11-01-2019 BUILDING 1 6TH FLOOR.
CPVC PIPE IS BURNED.
(PHOTO 1)
CPVC PIPE IS YELLOW AND BURNED.
(PHOTO 2)
FITTING IS RUSTED. REPLACE WITH NEW FITTING.
(PHOTO 3)
FITTING IS RUSTED. REPLACE WITH NEW FITTING.
(PHOTO 4)
FITTING IS RUSTED. REPLACE WITH NEW FITTING.
(PHOTO 5)
CPVC PIPE IS BURNED.
(PHOTO 6)
CLEAN FIRE STOP OFF OF PIPE.
(PHOTO 7)
SPRINKLER IS NEEDED TO COMPLETE COVERAGE UNDER DUCT.
ADD SPRINKLER UNDER DUCT. (PHOTO 8)
ADD HANGER TO CPVC. (PHOTO 9)
D6
A1
D6
A2
D6
A3
D6
A4
D6
A5
D6
A6
D6
A7
D6
A8
D6
A9
BIO-MED
TOILET
7424A
TOILET
7423A
TOILET
7437AELECTRICAL
74E1
PHONE
CLOSET
7451B
FIRE CT
7447A
FIRE CLOSET
CORRIDOR
C7402
CORRIDOR
C7404
VESTIBULE/
CHASE
DR ZIMMERMAN
CONFERENCE RM
EMS EQUIP
ELEVATOR
LOBBY
MECH A/C
ELEVATOR
P-1
ELEVATOR
P-2
ELEVATOR
P-3
ELEVATOR
P-4
ELEVATOR
S-6
ELEVATOR
S-5
CHIEF MED SVC
ELEVATOR
P-7
ELEVATOR
P-8
OFFICE
SUPPLY
SPECIALIST
74T1
STAIR
NO 1
ELECTRICAL
74E2
SUPPLY
TECH
STAIR
NO 2
ICE
M/C
STORAGE
STORAGE
7450A
STORAGE
WAITING RM
PATIENT EFFECTS UNIFORM EXCHANGE
SATV
BIOMED
SHOP
TOILET
7412A
BIOMED
SHOP
BIOMED
SHOP
CART
STORAGE
CABLE RM
REFERENCE BOOK RM
STORAGE
TOILET
7421A BIOMED
CHIEF
ICE M/C
TOILET
7422A
BIOMED
SHOP
BIOMED
SHOP
BIOMED
SHOP
BIOMED
SHOP
BIOMED
SHOP
BIOMED
SHOP
SUPV OFFICE
TELECOM
MGR
BREAKRM/
ALT
CONFERENCE
IRM
CHIEF
IRM
ASST
CHIEF
NEW AIR
HANDLER RM
HELP DESK
AREA
OFFICE
AREA
WOMEN'S
TOILET
UTILITY
CLOSET
COMPUTER LAB
AND STAGING
DATA
CENTER
CART
CLOSET
OFFICE
AREA
ELECTRICAL
CLOSET
UNISEX
TOILET
74H2
MEN'S
TOILET
SECURE
STORAGE 2
OFFICE
AREA
CLOSET
SECURE
STORAGE 1
OFFICE AREA
OFFICE
AREA
STAIRWELL
ELECTRIC
CLOSET
74E3
BIOMED
SERVER
ROLL-UP WINDOW ELECTRICAL
B01B
B01A NORTH
B
U
T H
B
R
T H
B
U
T H
B
R
T H
B01B
B01A NORTH
D7
A1
D7
A2
D7
A4
D7
A5
SHOWER
FIRE CLOSET
CORRIDOR
C7403
STAIR
NO 2
ICE
M/C
STORAGE
MENS TOILET
HAC
EQUIP STORAGE
EQUIP STORAGE
EQUIP STORAGE
EQUIP STORAGE
BIOMED
SHOP
TOILET
7412A
BIOMED
SHOP
BIOMED
SHOP
REFERENCE BOOK RM
TOILET
7421A
B
U
T H
B
R
T H
B
U
T H
B
R
T H
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions
31 E Ogden Ave Suite 304 LaGrange, IL 60535 312.583.7023 POC: Gary Collins
Sprinkler Corrections
Jesse Brown VAMC
Chicago, IL
537-16-102A
Project Director
Revisions: Date:
1/8"=1'-0"
4' 8'0 16'
Keyplan:
N
S B01A FX107
BUILDING 01A
SEVENTH FLOOR PLAN
08/30/2020
100% Complete and Final
Issued for 100% Complete and Final
Issued for 100% CD
08/30/2020
02/10/2020
B01
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 engineering discipline: Fire Protection Virtual Energy Solutions
31 E Ogden Ave Suite 304…