S06 - Drawing PD103.pdf

PDF 1 MB Posted

Attached to
Z1DZ--607-18-108 Renovate 4B for Inpatient Ward
Solicitation number
36C25221B0031
Issued by

About this file

This document provides details for a federal construction contract opportunity to renovate the fourth floor of Building 1, Wing B at the William S. Middleton Memorial Veterans Hospital in Madison, Wisconsin. The solicitation number is 36C25221B0031 and involves renovations and construction work across approximately 10,000 square feet, including demolition, hazardous material removal, various construction trades, HVAC, plumbing and medical gas systems work. The pre-solicitation notice states that the solicitation and drawings will be issued on or around September 20th, 2021 with a bid opening on or around October 20th, 2021. The project magnitude is estimated between $5-10 million and has a North American Industry Classification System code of 236220 with a size standard of $39.5 million. The completion time is listed as 550 calendar days from notice to proceed. The opportunity is set aside for Service-Disabled Veteran-Owned Small Businesses.

View the file

Other files

File Type Posted
36C25221B0031 0003.docx DOCX document
S06 - Drawing P100.pdf PDF
36C25221B0031 0002.docx DOCX document
S06 - Drawing P000.pdf PDF
S06 - Drawing P103.pdf PDF
S06 - Drawing PD104.pdf PDF
S06 - Drawing P104.pdf PDF
S06 - SF 1442 - Revised.pdf PDF
52.223-99.pdf PDF
36C25221B0031 0001.docx DOCX document
852.219-77.pdf PDF
S04 - Pre-Bid Sign in Sheet.pdf PDF
S02 - Drawings VOL2A.pdf PDF
36C25221B0031_1.docx DOCX document
S02 - Drawings VOL1B.pdf PDF
P07 - Wage Determination.pdf PDF
S02 - Drawings VOL2B.pdf PDF
S02 - Specifications - Volume 1.pdf PDF
S02 - Drawings VOL2C.pdf PDF
S02 - Drawings VOL1A.pdf PDF
S02 - Specifications - Volume 2.pdf PDF
S02 - Drawings VOL1C.pdf PDF
Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COMPLETELY REMOVE SANITARY PIPE BACK TO DEMOLISHED

PLUMBING FIXTURES ON FLOOR ABOVE. PATCH HOLES TO FLOOR

ABOVE. CAP DEMOLISHED SANITARY LINES AT EXISTING SANITARY

RISERS TO REMAIN. SEE P103 FOR REROUTED RISERS, NEW WORK

AND NEW CONNECTIONS.

ALL HW AND CW VERTICAL PIPE HAS BEEN ABANDONED. DEMOLISH

ALL HW AND CW PENETRATIONS FROM FLOOR ABOVE. PATCH HOLES

TO FLOOR ABOVE. CAP ANY REMAINING EXPOSED THIRD FLOOR HW

AND CW PIPE HIGH. ALL W, V, ST, AND AV RISERS TO FOURTH FLOOR

ARE TO BE REMAIN ACTIVE, AND ARE TO BE REROUTED WHERE

NECESSARY AND AS SHOWN ON NEW WORK PLANS. TYPICAL ALL

LOCATIONS.

KEYED DEMOLITION NOTES (PD103):

GENERAL NOTES (PD103):

1. EXISTING THIRD FLOOR PIPE SHOWN IS BEING INSTALLED AS PART OF A

CURRENTLY IN-PROGRESS SEPARATE PROJECT (VA PROJECT NO.

607-15-101), FOR REFERENCE ONLY.

2. DUE TO LIMITED DESIGN ACCESS AND VERIFICATION, CONTRACTOR IS TO

ASSUME A REASONABLE NUMBER OF PIPING FLOOR PENETRATIONS AND

HORIZONTAL RUNS ARE DIFFERENT FROM THOSE SHOWN ON THESE

DRAWINGS, AND IS TO INCLUDE COST FOR THOSE CHANGES IN BUDGET.

3. ALL WORK ON THIRD FLOOR SHALL BE PHASED AND COORDINATED WITH

VA BEFORE STARTING. CONTRACTOR SHALL ONLY BE ABLE TO ACCESS

TWO ROOMS AT A TIME, AND MUST BE COMPLETE BEFORE GIVEN ACCESS

TO THE NEXT TWO.

4. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS (INCLUDING

CEILING TYPE), PRIOR TO BIDDING.

5. ALL GYPSUM BOARD CEILINGS ARE TO BE PATCHED AND PAINTED TO

MATCH EXISTING. HARD CEILING AREAS (PATIENT BATHROOMS) HAVE

LIMITED TO NO ACCESS PANELS.

6. ACCESS TO OFFICE SPACE IS CONSIDERED AFTER HOURS WORK

7. OFFICE SPACE AFTER HOURS IS 5PM TO 7AM MONDAY - FRIDAY.

8. 3B DAY WORK 7AM to 7PM

WC

WC

L

SH

L

L

WC

FD

FD L

L

WC

FD

S

L

LWC

WC

SH

FD

WC WC

WC

WC

WC

WC

WC

WC

L

L

L

L

L L

L

L

SH

SH

FD

FD

FD

S-2

CSS

FD

S

3" 2"

1"

4"

4"

2"

4" 2"

4"

2"

4"

2"

4" 2"

2"

3"

TYPICAL SINK:

2" W DN, 11

2" V UP

2" H & CW DN

4" W DN, 11

2" V UP

2" CW DN

L

L

L L

L

L

L

FD

2" V DN

(2)11

2" V DN

SH 11

2" V DN

(2)11

2" V DN

2" 2"

2"

2"

2"

4" V, 5" W UP

2"

2"

2"

1-1/2" V DN

2"

SH

WC

SH

1-1/2" V DN

2"

2"

2"

(2)11

2" V DN

(2)11

2" V DN

2"

SH

2"

SH

2"

2"SH

SH

SH

2"2"

L

LL

LL L

L

LL 11

2"

2"

L

L

1/2"

2"

EWC

1/2"

4" 2"

2"

2"

2" 2"

2"

2"

2"

2"2"2"

2"

2"

2"3"

2"

2"

L L

5" W, 4" V DN

2-1/2" CW, 1" HW DN

4" W, 2" V, 5"ST DN

3" CW, 1-1/2" HW

2"

4" W, 4" V DN

2"

1-1/2" V DN

1-1/2" V DN

L

4"

2"

FD

2" 3"

L

2"

2"

ICE MACHINE

'B' WING RISER

2" CW, 1" HW, 4" W, 2" V

1/2"

1-1/2" 1/2"

3/4"

1-1/4" 3/4"

3/4"

1-1/4"

1/2"

1/2"

1/2"

FD

SH

2-1/2"FD

FD

SH

3/4" 3/4"

3/4" 3/4"

3/4"

WC

1/2"

1/2" 1/2" 2" 1"

FD

1/2"

FD

SH

L

FD

SH

FDFD

2-1/2" CW, 1-1/4" HW,

4" W, 2" V DN

3/4" 1/2" 1/2"

3/4"

3/4" 1/2" 3/4"

3/4"

1 1

1 1

3" CW, 1" HW,

4" W, 3" V UP & DN

2" AV UP

3/4" CW, 3/4" HW,

2" W, 1-1/4" V

UP & DN

4" W, 3" V DN

2" CW, 1-1/2" HW DN

3/4"CWR FFA/TFB

4"CW FFB/TBA

3"HW FFB/TFA

1-1/2"HWR FFA/TFB

4" W, 4" V UP

1-1/2" HW, 2" CW UP

DEMO 1-1/2"V-FFA2

2 2 2

2 1

2 222

2 2

4" W, 2-1/2"V, 2"AV, 6"ST

1-1/2"HW, 2"CW

4" W, 2-1/2" V UP & DN

12" 0 1' 5' 10' 20'

SCALE: 1/8" = 1'-0"

THIRD FLOOR PLAN - PLUMBING DEMOLITION1

B B

A

C

MAM MAM10/19/2021Schematic Design Documents 11.27.2018 Design Developement Documents 5.16.2019 65% Construction Documents 11.11.2019 95% Construction Documents 09.04.2020 100% Construction Documents 11.12.2020

"ACCOMPANYING AMENDMENT 36C25221B0031 - 0002"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text

UP

AutoCAD SHX Text

DN

AutoCAD SHX Text

UP

AutoCAD SHX Text

DN

AutoCAD SHX Text B3060

AutoCAD SHX Text

STAFF

AutoCAD SHX Text

BATHROOM

AutoCAD SHX Text

75 SF

AutoCAD SHX Text B3081

AutoCAD SHX Text

NURSE

AutoCAD SHX Text

STATION

AutoCAD SHX Text

443 SF

AutoCAD SHX Text B3061

AutoCAD SHX Text

BARIATRIC

AutoCAD SHX Text

PATIENT ROOM

AutoCAD SHX Text

264 SF

AutoCAD SHX Text B3061A

AutoCAD SHX Text

BARIATRIC

AutoCAD SHX Text

BATHROOM

AutoCAD SHX Text

113 SF

AutoCAD SHX Text B3069A

AutoCAD SHX Text

PATIENT

AutoCAD SHX Text

BATHROOM

AutoCAD SHX Text

66 SF

AutoCAD SHX Text B3080A

AutoCAD SHX Text

PATIENT

AutoCAD SHX Text

BATHROOM

AutoCAD SHX Text

69 SF

AutoCAD SHX Text B3064A

AutoCAD SHX Text

ISOLATION

AutoCAD SHX Text

PATIENT ROOM

AutoCAD SHX Text

165 SF

AutoCAD SHX Text B3073

AutoCAD SHX Text

EQUIPMENT

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

300 SF

AutoCAD SHX Text B3100K

AutoCAD SHX Text C.O.W.

AutoCAD SHX Text

ALCOVE

AutoCAD SHX Text

15 SF

AutoCAD SHX Text B3100D

AutoCAD SHX Text C.O.W.

AutoCAD SHX Text

ALCOVE

AutoCAD SHX Text

17 SF

AutoCAD SHX Text B3067A

AutoCAD SHX Text

BARIATRIC

AutoCAD SHX Text

BATHROOM

AutoCAD SHX Text

118 SF

AutoCAD SHX Text B3062A

AutoCAD SHX Text

ISOLATION

AutoCAD SHX Text

PATIENT ROOM

AutoCAD SHX Text

169 SF

AutoCAD SHX Text B3070A

AutoCAD SHX Text

PATIENT

AutoCAD SHX Text

BATHROOM

AutoCAD SHX Text

66 SF

AutoCAD SHX Text B3064B

AutoCAD SHX Text

PATIENT

AutoCAD SHX Text

BATHROOM

AutoCAD SHX Text

66 SF

AutoCAD SHX Text B3068

AutoCAD SHX Text

PATIENT

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

208 SF

AutoCAD SHX Text B3070

AutoCAD SHX Text

PATIENT

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

204 SF

AutoCAD SHX Text B3076

AutoCAD SHX Text

PATIENT

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

209 SF

AutoCAD SHX Text B3074A

AutoCAD SHX Text

PATIENT

AutoCAD SHX Text

BATHROOM

AutoCAD SHX Text

62 SF

AutoCAD SHX Text B3076A

AutoCAD SHX Text

PATIENT

AutoCAD SHX Text

BATHROOM

AutoCAD SHX Text

65 SF

AutoCAD SHX Text B3080

AutoCAD SHX Text

PATIENT

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

203 SF

AutoCAD SHX Text B3082A

AutoCAD SHX Text

PATIENT

AutoCAD SHX Text

BATHROOM

AutoCAD SHX Text

65 SF

AutoCAD SHX Text B3092A

AutoCAD SHX Text

PATIENT

AutoCAD SHX Text

BATHROOM

AutoCAD SHX Text

68 SF

AutoCAD SHX Text B3094B

AutoCAD SHX Text

PATIENT

AutoCAD SHX Text

BATHROOM

AutoCAD SHX Text

61 SF

AutoCAD SHX Text B3086A

AutoCAD SHX Text

PATIENT

AutoCAD SHX Text

BATHROOM

AutoCAD SHX Text

62 SF

AutoCAD SHX Text B3088A

AutoCAD SHX Text

PATIENT

AutoCAD SHX Text

BATHROOM

AutoCAD SHX Text

65 SF

AutoCAD SHX Text B3098B

AutoCAD SHX Text

PATIENT

AutoCAD SHX Text

BATHROOM

AutoCAD SHX Text

65 SF

AutoCAD SHX Text B3086

AutoCAD SHX Text

PATIENT

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

210 SF

AutoCAD SHX Text B3088

AutoCAD SHX Text

PATIENT

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

208 SF

AutoCAD SHX Text B3092

AutoCAD SHX Text

PATIENT

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

205 SF

AutoCAD SHX Text B3094A

AutoCAD SHX Text

PROTECTIVE

AutoCAD SHX Text

PATIENT ROOM

AutoCAD SHX Text

205 SF

AutoCAD SHX Text B3098A

AutoCAD SHX Text

PROTECTIVE

AutoCAD SHX Text

PATIENT ROOM

AutoCAD SHX Text

162 SF

AutoCAD SHX Text B3081A

AutoCAD SHX Text

NOURISHMENT

AutoCAD SHX Text

90 SF

AutoCAD SHX Text B3089

AutoCAD SHX Text

SOILED

AutoCAD SHX Text

UTILITY

AutoCAD SHX Text

127 SF

AutoCAD SHX Text B3100H

AutoCAD SHX Text

CRASH CART

AutoCAD SHX Text

ALCOVE

AutoCAD SHX Text

16 SF

AutoCAD SHX Text B3099

AutoCAD SHX Text

STAFF

AutoCAD SHX Text

LOUNGE

AutoCAD SHX Text

256 SF

AutoCAD SHX Text B3095

AutoCAD SHX Text

MECHANICAL

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

418 SF

AutoCAD SHX Text B3082

AutoCAD SHX Text

PATIENT

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

205 SF

AutoCAD SHX Text B3098

AutoCAD SHX Text

VESTIBULE

AutoCAD SHX Text

44 SF

AutoCAD SHX Text No. 1

AutoCAD SHX Text

STAIR

AutoCAD SHX Text

227 SF

AutoCAD SHX Text No. 2

AutoCAD SHX Text

STAIR

AutoCAD SHX Text

157 SF

AutoCAD SHX Text B3064

AutoCAD SHX Text

VESTIBULE

AutoCAD SHX Text

43 SF

AutoCAD SHX Text B3087

AutoCAD SHX Text

CLEAN LINEN

AutoCAD SHX Text

102 SF

AutoCAD SHX Text B3093

AutoCAD SHX Text

NURSE MNGR

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

75 SF

AutoCAD SHX Text B3081B

AutoCAD SHX Text

MEDICATIONS

AutoCAD SHX Text

89 SF

AutoCAD SHX Text B3091

AutoCAD SHX Text

CONSULT ROOM

AutoCAD SHX Text

154 SF

AutoCAD SHX Text B3085

AutoCAD SHX Text

CLEAN UTILITY

AutoCAD SHX Text

100 SF

AutoCAD SHX Text B3074

AutoCAD SHX Text

PATIENT

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

211 SF

AutoCAD SHX Text B3068A

AutoCAD SHX Text

PATIENT

AutoCAD SHX Text

BATHROOM

AutoCAD SHX Text

64 SF

AutoCAD SHX Text B3062B

AutoCAD SHX Text

PATIENT

AutoCAD SHX Text

BATHROOM

AutoCAD SHX Text

78 SF

AutoCAD SHX Text B3062

AutoCAD SHX Text

VESTIBULE

AutoCAD SHX Text

44 SF

AutoCAD SHX Text B3067

AutoCAD SHX Text

BARIATRIC

AutoCAD SHX Text

PATIENT ROOM

AutoCAD SHX Text

228 SF

AutoCAD SHX Text B3069

AutoCAD SHX Text

PATIENT

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

211 SF

AutoCAD SHX Text B3091A

AutoCAD SHX Text

ASST. NURSE

AutoCAD SHX Text

MNGR OFFICE

AutoCAD SHX Text

55 SF

AutoCAD SHX Text B3100E

AutoCAD SHX Text

MEDICATION

AutoCAD SHX Text

ALCOVE

AutoCAD SHX Text

21 SF

AutoCAD SHX Text B3100A

AutoCAD SHX Text C.O.W.

AutoCAD SHX Text

ALCOVE

AutoCAD SHX Text

15 SF

AutoCAD SHX Text B3100B

AutoCAD SHX Text

ALCOVE

AutoCAD SHX Text

4 SF

AutoCAD SHX Text B3100F

AutoCAD SHX Text

ALCOVE

AutoCAD SHX Text

4 SF

AutoCAD SHX Text B3100I

AutoCAD SHX Text

ALCOVE

AutoCAD SHX Text

4 SF

AutoCAD SHX Text B3100

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text

1,786 SF

AutoCAD SHX Text B3100

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text

1,786 SF

AutoCAD SHX Text B3100

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text

1,786 SF

AutoCAD SHX Text B3100C

AutoCAD SHX Text C.O.W.

AutoCAD SHX Text

ALCOVE

AutoCAD SHX Text

8 SF

AutoCAD SHX Text B3100G

AutoCAD SHX Text

ALCOVE

AutoCAD SHX Text

6 SF

AutoCAD SHX Text B3100L

AutoCAD SHX Text C.O.W.

AutoCAD SHX Text

ALCOVE

AutoCAD SHX Text

7 SF

AutoCAD SHX Text B3100J

AutoCAD SHX Text

ALCOVE

AutoCAD SHX Text

5 SF

AutoCAD SHX Text B3094

AutoCAD SHX Text

VESTIBULE

AutoCAD SHX Text

44 SF

AutoCAD SHX Text B3100M

AutoCAD SHX Text

ALCOVE

AutoCAD SHX Text

6 SF

AutoCAD SHX Text

FEC

AutoCAD SHX Text

FEC

AutoCAD SHX Text

FEC

AutoCAD SHX Text

FEC

AutoCAD SHX Text

TUBE STATION 230

AutoCAD SHX Text

DIVERTER 26

AutoCAD SHX Text 14"x22"

AutoCAD SHX Text 12"x12"

AutoCAD SHX Text 22"x5"

AutoCAD SHX Text 28"x16"

AutoCAD SHX Text

ELECTRICAL POKE-THRU DEVICE

AutoCAD SHX Text

STAMP

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text Approved: Project Director

AutoCAD SHX Text Project Title

AutoCAD SHX Text Date

AutoCAD SHX Text Location

AutoCAD SHX Text Checked

AutoCAD SHX Text Building Number

AutoCAD SHX Text Project Number

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Drawn

AutoCAD SHX Text Revisions:

AutoCAD SHX Text Date

AutoCAD SHX Text

CONSULTANTS:

AutoCAD SHX Text

ARCHITECT/ENGINEERS:

AutoCAD SHX Text one eighth inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text three inches = one foot

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text one and one half inches = one foot

AutoCAD SHX Text one inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three quarters inch = one foot

AutoCAD SHX Text one half inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three eighths inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text one quarter inch = one foot

AutoCAD SHX Text

VA FORM 08-6231

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Office of Construction and Facilities Management

AutoCAD SHX Text

RENOVATE 4B FOR INPATIENT WARD

AutoCAD SHX Text William S. Middleton Memorial VA, Madison WI

AutoCAD SHX Text 607-18-108

AutoCAD SHX Text Bldg 1 4th Floor B-Wing

AutoCAD SHX Text N

AutoCAD SHX Text

KEY PLAN

AutoCAD SHX Text Not to Scale

AutoCAD SHX Text

100% CONSTRUCTION DOC

AutoCAD SHX Text

PD103

AutoCAD SHX Text

THIRD FLOOR PLAN - PLUMBING DEMOLITION

File details come from the government source that posted it. Updated .