36C25220B0003-013.pdf
PDF Posted
- Solicitation number
- 36C25220B0003
About this file
This document contains a justification for a single source award and details of a federal contract opportunity for replacement of chillers and air handling units at the Clement J. Zablocki VA Medical Center in Milwaukee, Wisconsin.
The single source justification is for the purchase of Johnson Controls Metasys Building Automation hardware for $20,000. It cites compatibility issues with the existing campus-wide Johnson Controls system as necessitating a single source award.
The federal contract opportunity involves project 695-19-137 to replace chillers and air handling units in Building 43, which provides outpatient mental health services. The project scope includes replacing two air handling units with a new packaged rooftop unit and single larger unit, demolishing the existing chiller system, upgrading controls, and replacing lighting. The project value is estimated between $1 million to $2 million. The solicitation is scheduled to post on October 28, 2019 with bid opening on December 4, 2019. The 240-day period of performance will begin with notice to proceed. The opportunity is set aside for verified Service-Disabled Veteran-Owned Small Businesses. The NAICS code is 238220 for heating, ventilation, and air conditioning contractors up to $15 million in annual receipts.
36C25220B0003 J_A Bldg Automation.pdf
View the file
Other files
Show 40 more
Latest 50 of 74 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VHAPM Part 813.106 Simplified Acquisition Procedures: Soliciting from a Single Source Attachment 1: Single Source Justification for SAP under the SAT
VHAPM Part 813.106 Page 1 of 1 Original Date: 08/30/17 Revision 01 Eff Date: 04/23/2018
DEPARTMENT OF VETERANS AFFAIRS
Justification for Single Source Awards IAW FAR 13.106‐1 For
Over Micro‐Purchase Threshold but Not Exceeding the SAT ($250K)
Acquisition Plan Action ID: 36C252‐20‐AP‐0060
1. Contracting Activity: Department of Veterans Affairs, Great Lakes Acquisition Center, NCO 12, 115 South 84th Street, Milwaukee, WI 53214. Requesting Activity: Department of Veterans Affairs, VISN 12, Clement J. Zablocki VA Medical Center, 5000 W. National Avenue, Milwaukee WI 53295. Purchase Request (2237) number: 695‐20‐1‐6908‐
2. Brief Description of Supplies/ Services required and the intended use/Estimated Amount: The equipment to be installed will be monitored and controlled by Johnson Controls Metasys Building Automation and HVAC Control System. A new panel and necessary controllers will be installed and tied into the existing system, to be monitored and controlled by VA’s ‘Graphics’ shop.
The estimated cost for Johnson Controls Metasys Building Automation hardware is $20,000.00
3. Unique characteristics that limit availability to only one source, with the reason no other supplies or services can be used: This product, the Johnson Controls Metasys Building Automation and HVAC Control System, is the only product that allows for a single HVAC control system for the Milwaukee facility. Johnson Controls Metasys control system is the campus‐wide building and HVAC control System. An incompatible system may require installation of new “front‐end” and remote workstations as well as new software and programming. Additionally, installation of components that match the existing building automation system minimizes maintenance costs and bench stock requirements. It is necessary to match the existing system to ensure there are no interface problems, impacts to patient safety and familiarity of the product to the staff and maintenance personnel. This is the only way to ensure complete compatibility and that the campus will not have two HVAC control systems on the Milwaukee campus.
4. Description of market research conducted and results or statement why it was not conducted: We have conducted research into other Building Automation and HVAC Control systems and have found that they are not compatible with our standard. The other products on the market would require additional cost to maintain within the facility.
5. Contracting Officer's Certification: Purchase is approved in accordance with FAR13.106‐1(b). I certify that the foregoing justification is accurate and complete to the best of my knowledge and belief.
Jerrod Schleis Date Contracting Officer
VHAMIWSchleJ Typewritten Text 10-04-2019
| 2019-10-04T13:34:29-0500 | |
| Jerrod J Schleis 1002181 |
File details come from the government source that posted it. Updated .