36C25218B1095-0001001.pdf
PDF 7 MB Posted
- Attached to
- 585-17-111 - Upgrade AHU-09 and Locker Room at the Oscar G Johnson VA Medical Center Iron Mountain, MI 49801
- Solicitation number
- 36C25218B1095
About this file
36C25218B1095 0001 S06- 0001 At1 Revised Drawings 10.8.2018.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25218B1095-0003000.docx | DOCX document | |
| 36C25218B1095-0003001.pdf | ||
| 36C25218B1095-0002001.pdf | ||
| 36C25218B1095-0002002.pdf | ||
| 36C25218B1095-0002000.docx | DOCX document | |
| 36C25218B1095-0001003.pdf | ||
| 36C25218B1095-0001000.docx | DOCX document | |
| 36C25218B1095-0001002.docx | DOCX document | |
| 36C25218B1095-001.docx | DOCX document | |
| 36C25218B1095-002.pdf | ||
| 36C25218B1095-004.docx | DOCX document | |
| 36C25218B1095-003.pdf | ||
| 36C25218B1095-000.docx | DOCX document |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A.D.A. ACCESSIBLE
ACOUSTICAL
ACOUSTICAL CEILING TILE
ADJUSTABLE
ABOVE FINISHED FLOOR
ALTERNATE
ANESTHESIA
APPROXIMATE
ARCHITECTURAL
AUTOMATIC
BUILDING
BLOCKING
BOTTOM
CABINET
CERAMIC
CORNER GUARD (NUMBER/TYPE)
CABINET HEATER
CONTROL JOINT
CENTERLINE
CEILING
CONCRETE MASONRY UNIT
COLCOLUMN
CONCRETE
CONTINUOUS
CORRIDOR
CHAIR RAIL (NUMBER/TYPE)
CLINIC SINK
CENTER
CUBICLE
DOUBLE
DEPARTMENT
DRINKING FOUNTAIN
DIAMETER
DICTATION
DIMENSION
DOWNSPOUT
DUMBWAITER
DRAWING
EACH
ELEVATION
ELECTRICAL
ELEVATOR
EMERGENCY
ELECTRICAL PANEL
EMERGENCY EXIT PUSH BUTTON
EQUAL
CETERA
ELECTRIC WATER COOLER
EXISTING
EXPANSION
EXTERIOR
FLOOR DRAIN
FOUNDATION
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
FINISH
FLASHING
FLOOR
FLUOROSCOPY
FINISHED OPENING
FRAME
FEET OR FOOT
FOOTING
GAUGE
GALVANIZED
GRAB BAR
GENERAL CONTRACTOR
GYPSUM BOARD
HOSE CABINET
HEADER
HOLLOW METAL
HORIZONTAL
HOUR
HAND RAIL (NUMBER/TYPE)
HOUSEKEEPING
HSSHOLLOW STRUCTURAL STEEL
HEIGHT
HOLE THROUGH ROOF
HEATING, VENTILATING, AND CONDITIONING
INSIDE DIAMETER
INSULATION
INTERIOR
JOINT
KITCHEN
KEY PAD
LAVATORY
LABORATORY
LAMINATE
POUND(S)
LOCKER
LIGHT
MAXIMUM
MECHANICAL
MANUFACTURER
MINIMUM
MISCELLANEOUS
MASONRY OPENING
METAL
NOT IN CONTRACT
NUMBER(S)
NOMINAL
NOT TO SCALE
ON CENTER
OUTSIDE DIAMETER
OFFICE
OPPENING
OPPOSITE
PARTITION
PUSH BUTTON (NUMBER/TYPE)
PROXIMITY CARD READER
PLATE
PLASTIC LAMINATE
PLASTER
PLUMBING
PAIR
RISER
RADIUS
ROOF DRAIN
REFRIGERATOR
REINFORCED
REQUIRED
ROOM(S)
ROUGH OPENING
SINK
SCHEDULE
SQUARE FEET
SHOWER
SIMILAR
SPECIFICATION
SQUARE
SCRUB SINK
STAINLESS STEEL
STANDARD
STEEL
STORAGE
STRUCTURAL
SUPPORT
SYMMETRICAL
TREAD
TOP OF
TELEPHONE
TERRAZZO
TOILET
TRACK
(PNEUMATIC) TUBE STATION
TYPICAL
UNDER COUNTER OR UNDER CABINET
VALVE CABINET
VINYL COMPOSITION TILE
VERIFY
VERTICAL
VESTIBULE
VENT STACK
VINYL WALL COVERING
WITH
WAINSCOT
WATER CLOSET
WEIGHT
(A)
ACOUS
ACT
ADJ
AFF
ALT
ANES
APPROX
ARCH
AUTO
BLDG
BLKG
BOTT
CAB
CER
CG(#)
CH
CJ
CL
CLG
CMU
COL
CONC
CONT
CORR
CR(#)
CS
CTR
CUB
DBL
DEPT
DF
DIA
DICT
DIM
DS
DUMB
DWG
EA
EL
ELEC
ELEV
EMER
EP
EPB
EQ
ETCET
EWC
EXIST
EXP
EXT
FD
FDN
FE
FEC
FIN
FLASH
FLR
FLUOR
FO
FR
FT
FTG
GA
GALV
GB
GC
GYP
HC
HDR
HM
HOR
HR
HR(#)
HSKP
HSS
HT
HTR
HVAC
ID
INSUL
INT
JT
KIT
KP
L
LAB
LAM
LB(S)
LKR
LT
MAX
MECH
MFGR
MIN
MISC
MO
MTL
NIC
NO(S)
NOM
NTS
OC
OD
OFF
OPG
OPP
PART
PB(#)
PCR
PL
PLAM
PLAS
PLBG
PR
R
RAD
RD
REF
REINF
REQ
RM(S)
RO
S
SCHED
SF
SH
SIM
SPEC
SQ
SS
ST STL
STD
STL
STOR
STRUC
SUPP
SYM
T T/
TELE
TERR
TLT
TRK
TS
TYP
UC
VC
VCT
VER
VERT
VEST
VS
VWC
W/
WAINS
WC
WT
MATERIALS
ACOUSTICAL
CEILING TILE PARTICLE BOARD
BATT INSULATION /
SOUND ATTENUATION
PLASTER /
MORTAR
PLYWOOD
PRECAST CONCRETE
PREFORMED WALL PANEL
BITMINOUS PAVING
CARPET
CONCRETE
CONCRETE BLOCK RIGID INSULATION
CUT STONE
EXISTING
CONSTRUCTION
BRICK
GYPSUM BOARD
MARBLE/TRAVERTINE
STEEL
STRUCTURAL
GLAZED TILE
TERRAZZO
CONTINUOUS
WOOD BLOCKING
WOOD TRIM
WOOD SHIMMETAL STUD PARTITION
SINGLE LAYER
GRAVELMETAL STUD PARTITION
DOUBLE LAYER
OPENING NUMBER
OPENING WIDTH
OPENING NUMBER
BORROWED LITE /
PASS THRU
BL/PT
SECTION NUMBER
SHEET NUMBER
36"
SYMBOLS
PARTITION TYPE
WINDOW TYPE
NEW DOOR
NEW ELEVATION
LOCATION OF CEILING
MOUNTED EQUIPMENT
SUPPORT ABOVE
A.D.A. ACCESSIBLE(A)
KEYED NOTE
CORNER GUARD
EXISTING DOOR
EXISTING ELEVATION
EXISTING
CONSTRUCTION
TO BE REMOVED
(SHORT DASHES)
EQUIPMENT IN
SEPARATE CONTRACT
E
WALL
CEILING HEIGHT
PARENTHESIS INDICATES
EXISTING CEILING HEIGHT
CEILING TYPE/FINISH
CEILING MATERIAL
FINISH TYPE
ROOM
CEILING HEIGHT
PARENTHESIS INDICATES
EXISTING CEILING HEIGHT
8'-0"
8'-0"
A1
A101
DETAIL NUMBER
SHEET NUMBER
S3A
A1
A101
A1
A101
ELEVATION NUMBER
SHEET NUMBER
ROOM NAME
ROOM NAME
VIEW TITLE
SCALE
A7
VIEW NUMBER
ON SHEET
NEW COLUMN GRID
EXISTING COLUMN GRID
1. VERIFY ALL DIMENSIONS RELATING NEW CONSTRUCTION TO EXISTING CONSTRUCTION.
2. EXISTING FLOOR STRUCTURE IS A BEAM AND JOIST SLAB WITH 2" TOPPING, 2 1/2" SLAB, AND 8" CONCRETE JOISTS.
FROM BASEMENT FLOOR TO UNDERSIDE OF STRUCTURE ABOVE IS APPROXIMATELY 11'-11 1/2" (VERIFY).
3. UNLESS NOTED OTHERWISE, DIMENSIONS ON PLANS LOCATING INTERIOR PARTITIONS ARE TO FACE OF CONCRETE BLOCK, OR FACE OF OUTER LAYER OF GYPSUM BOARD. DIMENSIONS IGNORE APPLIED CERAMIC TILE.
4. GENERAL TRADE SHALL PATCH HOLES IN SLABS, PARTITIONS, AND CEILINGS CAUSED BY ANY TRADE AS FOLLOWS:
A. AT REMOVED DUCTWORK, CONDUIT, AND PIPING
B. AT NEW DUCTWORK, CONDUIT AND PIPING IN EXISTING PARTITIONS
C. AT ADDED OR REMOVED PARTITION MOUNTED ITEMS
5. WHERE EXPOSED TO VIEW, PATCHED SURFACES SHALL MATCH ADJACENT FINISHES. WORK SHALL MAINTAIN
EXISTING SEPARATION RATINGS.
6. GENERAL TRADE SHALL REMOVE ACOUSTICAL TILE AND GYPSUM BOARD WHERE REQUIRED FOR MECHANICAL OR ELECTRICAL TRADES. REINSTALL ACOUSTICAL TILE AND PATCH GYPSUM BOARD WHEN WORK ABOVE CEILING HAS
BEEN COMPLETED.
7. UNLESS DIMENSIONED OTHERWISE, LOCATE DOOR FRAMES AS FOLLOWS:
A. FROM PARTITION PERPENDICULAR TO DOOR, TO HINGE PLATE ON DOOR FRAME: 4"
B. CROSS CORRIDOR DOUBLE DOORS: CENTER IN CORRIDOR
C. DOUBLE EGRESS DOORS: CENTER IN CORRIDOR
8. CONSTRUCTION IN SOME AREAS SURROUNDING THE LIMITS OF THIS CONTRACT IS CURRENTLY IN PROGRESS.
ACTUAL EXISTING CONDITIONS MAY VARY FROM CONDITIONS INDICATED ON THESE DRAWINGS.
9. SEE SPECIFICATION SECTION 01 35 26 FOR INFECTION CONTROL. SEE SPECIFICATION SECTION 01 00 00 FOR PHASING
AND WORK TIME LIMITATIONS.
10. WHERE MASONRY PARTITIONS ARE REMOVED RESULTING IN A VOID, TOPPING SHALL BE PATCHED WITH CONCRETE.
SEE NEW ROOM FINISH SCHEDULE AND REFER TO THE FOLLOWING FOR ADDTIONAL REQUIREMENTS:
A. TOPPING INFILL, SEE
B. WHERE PROJECT CONSTRUCTION SCHEDULING DOES NOT ALLOW CONCRETE TOPPING TO CURE TO MOISTURE LEVELS REQUIRED BY FLOORING MATERIAL INSTALLATION GUIDELINES, UTILIZE CEMENTITIOUS CAST
UNDERLAYMENT AT TOPPING INFILLS.
11. CONCRETE TOPPING SHALL BE POURED PRIOR TO ERECTING PARTITIONS. SEE NEW FINISH SCHEDULE AND
DETAIL FOR TOPPING DEPRESSION REQUIREMENTS
12. FOR FLOOR TRANSITION DETAILS, SEE
13. PROVIDE BLOCKING FOR ALL PARTITION MOUNTED ITEMS INCLUDING THOSE SHOWN ON THESE DRAWINGS TO BE
PROVIDED UNDER SEPARATE CONTRACT, SEE
14. CORNER GUARDS INDICATED THUS (CG, CG1, CG2) ON FLOOR PLANS, ARE TO BE SURFACE MOUNTED. FROM TOP OF
BASE TO CEILING. UNLESS NOTED OTHERWISE IN ROOM ELEVATIONS OR PLANS.
15. HANDRAILS INDICATED THUS (HR) ON FLOOR PLANS, SHALL BE AS SPECIFIED AND INSTALLED AT 2'-10" TO THE TOP OF HANDRAIL. PROVIDE BLOCKING IN NEW METAL STUD PARTITIONS AT ALL HANDRAILS. TERMINATE HANDRAILS WITHIN
2" OF ALL DOOR FRAMES, CORNERS, AND CORNER GUARDS.
16. FOR MOUNTING HEIGHTS AND LOCATIONS OF DEVICES PROVIDED BY OTHER TRADES, SEE
17. UNLESS OTHERWISE NOTED, EXTEND ROOM FINISHES AT CASEWORK AS FOLLOWS:
A. EXTEND FLOOR FINISH UNDER CASEWORK (EXCEPT AT CARPET AND INTEGRAL BASES).
B. EXTEND CERAMIC TILE (BOTH FULL HEIGHT & WAINSCOT) BEHIND CASEWORK (WALLCOVERING IS NOT REQUIRED
BEHIND CASEWORK.)
C. IT IS THE INTENT THAT ALL SURFACES CONCEALED BY CASEWORK BE FINISHED IN THE SAME MANNER AS THE ROOM. ONCE CASEWORK IS IN PLACE, INSTALL ADDITIONAL BASE MATERIAL TO BASE UNIT. MATERIAL SHALL
MATCH ROOM BASE UNLESS NOTED OTHERWISE ON CASEWORK ELEVATIONS.
18. PROVIDE SELF LEVELING UNDERLAYMENT WHERE RESILIENT FLOORING IS SCHEDULED. PREPARE EXISTING
FLOORING AS REQUIRED FOR SELF LEVELER.
19. WHERE MECHANICAL EQUIPMENT DOES NOT ALLOW STUDS TO EXTEND TO STRUCTURE, PROVIDE STRUCTURAL METAL STUD BOX HEADER BENEATH ALL EQUIPMENT. BOX HEADER SHALL BE CONSTRUCTED OF (2) STRUCTURAL STUDS LAID ON THEIR BACK SIDE UTILIZING THE SAME DIMENSION STUDS AS THE WALL BE CONSTRUCTED (IE, 3 5/8").
OPENINGS BETWEEN 8'-0" AND 12'-0" SHALL UTILIZE .0451 THICKNESS STUDS. OPENINGS LESS THAN 8'-0" SHALL
UTILIZE .0346 THICKNESS STUDS.
20. UNLESS NOTED OTHERWISE, CASEWORK ON A400 SERIES SHEETS IS PLASTIC LAMINATE. FOR CASEWORK LEGEND
SEE SHEET A701B
21. DOOR ELEVATIONS SHOWN IN ROOM ELEVATIONS ARE SYMBOLIC REPRESENTATIONS ONLY AND DO NOT REFLECT
SCHEDULED DOOR ELEVATIONS. SEE DOOR SCHEDULE FOR ACTUAL DOOR PANEL ELEVATION.
22. REMOVE SURFACE MOUNTED ELECTRICAL BOXES/CONDUIT/FIXTURES AT WALLS WITHIN SCOPE.
F6
A501B
F9
A501B
F7
A501B
E9
A501B
/B5 A601B
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
UPGRADE AHU 09 & LOCKER ROOM
OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
ARCHITECT/ENGINEER
310 Pine Street | Green Bay, WI 54301 920-432-4865 | www.berners-schober.com
BID DOCUMENTS
FULLY SPRINKLERED
Comm. Number: 5700.05
OCTOBER 8, 2018
585-17-111
U.S. Department of Veterans Affairs
C U s e rs \j p o g ra n t\ D o c u m e n ts
\O G
J M
C
C E
N T
R A
L A
R C
H jp o g ra n t.
rv t
/1
/2
:5
:0
P M
Checker Author
G001B
COVER SHEET
DWG. 1 OF 28
GENERAL
1 G001B COVER SHEET
ARCHITECTURAL
2 AD101B BASEMENT FLOOR - DEMOLITION PLAN
3 A101B BASEMENT FLOOR - NEW WORK PLAN
4 AR101B BASEMENT - REFLECTED CEILING PLAN
5 A401B ENLARGED PLANS AND ELEVATIONS
6 A501B MISCELLANEOUS DETAILS
7 A601B SCHEDULES AND DETAILS
8 A701B CASEWORK DETAILS
INTERIORS
9 I001B EXISTING AND NEW ROOM FINISH SCHEDULE
10 I101B INTERIOR FLOOR AND WALL SPECIAL PLANS
FIRE PROTECTION
11 F101B BASEMENT FLOOR FIRE PROTECTION PLANS
PLUMBING
12 PL101B BASEMENT FLOOR SANITARY PIPING PLANS
13 PP101B BASEMENT FLOOR WATER PIPING PLAN
14 PK601B DIAGRAMS AND DETAILS
HVAC
15 MD101B BASEMENT FLOOR PLAN - DEMOLITION
16 MH101B BASEMENT FLOOR PLAN - NEW WORK
17 MK501B DETAILS
18 MK502B DETAILS
19 MJ601B SCHEDULES
20 MJ602B SCHEDULES
ELECTRICAL
21 E001B ELECTRICAL SYMBOLS AND ABBREVIATIONS
22 ED101B BASEMENT DEMOLITION PLAN
23 EL101B BASEMENT LIGHTING PLAN
24 EP101B BASEMENT POWER PLAN
25 ET101B BASEMENT TELECOMMUNICATIONS PLAN
26 EY101B BASEMENT AUXILIARY SYSTEMS PLAN
27 FA101B BASEMENT FIRE ALARM PLAN
28 EK600B SCHEDULES
UPGRADE AHU 09 & LOCKER ROOM, OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
BID DOCUMENTS
OCTOBER 8, 2018
SHEET INDEX
DIRECTOR
ASSOCIATE DIRECTOR
ASSOCIATE DIRECTOR FOR N&PCS
CHIEF OF POLICE
CHIEF OF ENGINEERING
SAFETY MANAGER
INFECTION CONTROL NURSE
PATIENT SAFETY
AFGE
ENERGY ENGINEER
PRIVACY OFFICER
CLC SUPERVISOR
HOUSEKEEPING/NESS
OI&T
BIO-MED
INDUSTRIAL HYGIENIST
LOGISTICS
PHARMACY
APPROVALSABBREVIATIONSMATERIALS AND SYMBOLSGENERAL NOTES
Revisions: Date:
50% DESIGN SUBMITTAL 05/03/2018
BID DOCUMENTS 10/08/2018
E
E.5
F
G
H
J
K
L
M
N
O
P
S
22 24
30 31
Q
SHOWER
B226C
TOILET
B226B
LOCKER
B226A
LOUNGE
B226
MECH.
B224A
MECH.
B224C
ELEVATOR
LOBBY
B224
LAUNDRY
CHUTE
B230
STORAGE
LOGISTICS
B231
ETO
B291C MECH.
B231B
MECH.
B227
MECH.
B295A
DECONT.
B295
LOCKERS
B297
CORRIDOR
B299C-1
NON-EXP.
EQUIP.
B298A
WAREHOUSE
STORAGE
B298
DATA &
PHONE
B296
CORRIDOR
B299D-1
STOCK/
BREAKOUT
B287
PREPARATION
PACKAGING
B291B
ELECT.
B269
EMERG.
ELECT.
B267
SUPPLIES
B291
MECH.
B231A
CORRIDOR
B299B-1
SHAFT
STAIR 3
A
B
B
B
B
B B
B
PASSAGE
B299D-2
D
E
C
F
F
L
LL
G
K
B
B
B
B
H
J
N
M
L
P
V E
R
IF
Y
/2
R
R
Q
Q
Q
DEMOLITION NOTES
GENERAL DEMOLITION NOTES:
1. REMOVE ALL PARTITIONS, DOORS, FRAMES, PLUMBING FIXTURES,
EQUIPMENT, AND CASEWORK IN THEIR ENTIRETY SHOWN DASHED
ON THIS PLAN. COORDINATE WITH OWNER ITEMS TO BE SALVAGED.
2. REMOVE ALL SUSPENDED ACOUSTICAL TILE AND PLASTER CEILINGS
FROM ROOMS WITH NEW CEILINGS SCHEDULED (SEE REFLECTED
CEILING PLAN FOR LOCATIONS OF NEW CEILINGS). REMOVE CEILING
GRID, HANGER WIRES, FURRING CHANNELS, ETC., ALL AS REQUIRED
FOR FULL ACCESS TO STRUCTURE ABOVE AND TO CONFIRM
CONTINUITY OF ALL PARTITIONS TO REMAIN.
3. WHERE EXISTING CONSTRUCTION IS SCHEDULED TO REMAIN,
REPAIR/ PATCH OPENINGS (I.E. AFTER REMOVAL OF ADJACENT
WALLS, OUTLETS, GASES, LIGHTING FIXTURES, HANDRAILS,
GUARDRAILS, WALL PROTECTION, ETC.) IN WALLS, CEILINGS, AND
FLOORS THAT ARE NOT SCHEDULED TO RECEIVE NEW FINISHES,
PROVIDE SMOOTH AND INVISIBLE TRANSITIONS. MAINTAIN EXISTING
CODE AND FIRE RATING REQUIREMENTS.
4. WHERE EXISTING PARTITIONS ARE SHOWN TO REMAIN, THE
EXISTING PARTITION GYPSUM BOARD/PLASTER HEIGHT MAY NOT
EXTEND TO NEW SOFFIT/CEILING HEIGHT. EXTEND GYPSUM
BOARD/PLASTER AS REQUIRED TO ACCOMODATE NEW
SOFFIT/CEILING HEIGHT.
5. REMOVE OR PREP EXISTING FINISHES WHERE NEW FINISHES ARE
SCHEDULED IN THE NEW FINISH SCHEDULE.
6. UNLESS NOTED OTHERWISE, EXISTING PARTITIONS ARE
CONSTRUCTED OF CLAY TILE AND/OR GYPSUM BLOCK WITH 5/8"
PLASTER BOTH SIDES. PARTITIONS WERE CONSTRUCTED PRIOR TO
INSTALLATION OF 2" CONCRETE OR TERRAZZO TOPPING. TOPPING IS
UNBONDED WITH ISOLATION MEMBRANE.
7. REMOVE 3" TOPPING TO STRUCTURAL SLAB (IN AREAS SHOWN AS
THUS ) FOR INSTALLATION OF NEW TERRAZZO OR CERAMIC
MOSAIC TILE.
8. WHERE DEMOLITION OF CHASES OCCUR AND THE
PIPES/MECHANICAL PENETRATIONS IN THE CHASE ARE TO REMAIN.
A. CONFIRM THAT THE PIPES HAVE CONCRETE INFILLED AROUND
THEM FOR REQUIRED FIRE RATING. IF OPENING AROUND PIPES
EXIST, INFILL OPENING AROUND PIPES WITH CONCRETE TO
ACHIEVE REQUIRED RATING. [SEE: SLAB INFILL DETAILS]
B. FIRESTOP PIPES THROUGH FLOOR ABOVE AS REQUIRED TO
ACHIEVE TWO HOUR FIRE RATING.
9. REMOVE FLOOR TILE TO STRUCTURAL SLAB. INFILL TOPPING AS
REQUIRED FOR NEW FLOOR FINISH.
10. WHERE FLOOR OR WALL TILE IS SCHEDULED IN NEW FINISH
SCHEDULE, REMOVE FLOOR TOPPING AND WALL FINISHES AS
REQUIRED TO PROVIDE INSTALLATION METHOD. DETAILS INDICATED
IN SPECIFIED TCNA SYSTEM.
11. WHERE ADJACENT PARTITIONS AT COLUMNS ARE SCHEDULED TO
BE REMOVED, REMOVE FINISHES AT COLUMNS DOWN TO
STRUCTURE.
DEMOLITION KEYED NOTES:
A DEMO EXISTING TUNNEL ACCESS. REFER TO FLOOR PLAN FOR
NEW LOCATION.
B
C REMOVE CERAMIC TILE FLOOR TO STRUCTURAL SLAB. INFILL WITH
TOPPING AS REQUIRED FOR NEW FINISH.
D
DOOR, FRAME, AND HARDWARE TO BE REMOVED. TURN
HARDWARE OVER TO OWNER.
E
EXISTING LAUNDRY CHUTE TO REMAIN. PROVIDE NEW RATED
DOOR AS REQUIRED FOR UPDATED CONFIGURATION.
RELOCATE EXISTING LAUNDRY CHUTE ALARM.
F REMOVE VINYL COMPOSITION TILE IN THIS ENTIRE AREA. PREP
FOR SHOT-BLASTING AND CLEAR SEALANT.
G REMOVE EXISTING WINDOW SILL, JAMB, AND HEAD TRIM.
H REMOVE WALL ABOVE DOOR TO HEIGHT REQUIRED TO ALLOW FOR
BULKHEAD. COORDINATE WITH ARCHITECT PRIOR TO WALL
REMOVAL. SEE
J MODIFY EXISTING VINYL COMPOSITION TILE TO EXTEND TO CENTERLINE
OF DOORS.
K REMOVE CONCRETE LOCKER BASE AS REQUIRED TO ACCOMODATE
NEW CONSTRUCTION.
L EXISTING VINYL COMPOSITION FLOORING TO REMAIN IN THIS AREA.
M DEMO FOR NEW TUNNEL ACCESS.
N EXISTING TUNNEL ACCESS.
P REMOVE EXISTING WALL AS REQUIRED TO ACCOMODATE
EQUIPMENT REMOVAL AND REPLACEMENT
/F4 AR101B
Q EXISTING ASBESTOS ABATEMENT INFORMATION PROVIDED BY
OWNER FOR REFERENCE: ASSUMED LOCATION OF ACM INSULATED
VERTICAL PIPES. ASSUME A TOTAL OF 300 LINEAL FEET. REFER TO
SPEC SECTION 028213.13
R EXISTING ASBESTOS ABATEMENT INFORMATION PROVIDED BY
OWNER FOR REFERENCE: ASSUMED ACM LOCATED IN EXISTING
RATED DOORS. REFER TO SPEC SECTION 028213.13
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
UPGRADE AHU 09 & LOCKER ROOM
OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
ARCHITECT/ENGINEER
310 Pine Street | Green Bay, WI 54301 920-432-4865 | www.berners-schober.com
BID DOCUMENTS
FULLY SPRINKLERED
KEY PLAN:
Comm. Number: 5700.05
OCTOBER 8, 2018
585-17-111
U.S. Department of Veterans Affairs
C U s e rs \j p o g ra n t\ D o c u m e n ts
\O G
J M
C
C E
N T
R A
L A
R C
H jp o g ra n t.
rv t
/1
/2
:5
:5
P M
Checker Author
AD101B
BASEMENT FLOOR - DEMOLITION
PLAN
DWG. 2 OF 28
N
1/8" = 1'-0"
BASEMENT FLOOR - DEMOLITION PLAN
F9
Revisions: Date:
SCHEMATIC DESIGN 03/15/2018
E.5
F
G
H
J
K
L
M
N
O
P
R
S
22 24
30 31
Q
MECH.
B224A
MECH.
B224C
SHAFT
ELEVATOR
LOBBY
B224
STAIR 3
98 SF
LAUNDRY
B230
STORAGE
LOGISTICS
B231
MECH.
B231A
ETO
B291C MECH.
B231B
PREPERATION
PACKAGING
B291B MECH.
B227
MECH.
B295A
DECONT.
B295
LOCKERS
B297
CORRIDOR
B299C-1
NON-EXP.
EQUIP.
B298A
WAREHOUSE
STORAGE
B298
DATA &
PHONE
B296
CORRIDOR
B299D-1
ELECT.
B269
EMERG.
ELECT.
B267
STOCK/
BREAKOUT
B287
SUPPLIES
B291
CORRIDOR
B299B-1
EXTENT OF
CORRIDOR
WORK
99 SF
PASSAGE
B226
335 SF
MENS
LOCKER
B228B
409 SF
UNISEX
BREAKROOM
B228
360 SF
MENS
SHOWER
B228C
REF
4 5 5
B E
N C
H
CARD
READER
CG1
CG1
CG1
CG1
CG1
B E
N C
H
C9
A401B
F8
A401B
1/4"
PLAN
1/4"
PLAN
CG1
CG1
CG1
CG1
S3A
S3A S3A
U2A
U2A
CG1
CG1
CG1 CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
TOWELS /
HAMPER
LOCKER
VEST.
B228A
PASSAGE
B299D-2
B298-1
36"36"
B298-2
B228-1
42"
B230
48"
B228-2
42"
B228-3
36"
CG1
CG1
F0-
CG1
B296
30"
F.E.C.
F.E.C.
F1-
F1-
F1-
F1-
F1-
LAUNDRY
CART
E
SHIPPING &
RECEIVING
B274
CARD
READER
HR-1
HR-1 HR-1
HR-1
HR-1HR-1
HR-1HR-1
HR-1
HR-1
HR-1
HR-1 HR-1 HR-1 HR-1 HR-1
/2
HR-1
CG1
OFFICE
LOGISTICS
B299C-5
OXYGEN
STORAGE
B268
NEW CARD
READER
NEW WORK PLAN KEYED NOTES
1 EXISTING TUNNEL ACCESS
2 RELOCATED LAUNDRY CHUTE ALARM.
3 NEW TOPPING SLAB AFTER REMOVAL OF QUARRY TILE. SEE
4 PROVIDE NEW RATED LAUNDRY CHUTE DOOR TO ACCOMODATE
UPDATED CONFIGURATION.
5 INFILL TUNNEL ACCESS
6 NEW TUNNEL ACCESS
8 NEW SOLID SURFACE WINDOW SILL. SEE
9 LAMINATE GYPSUM BOARD TO EXISTING WALL TO FLUSH OUT WALL
SURFACE. SEE ROOM FINISH SCHEDULE FOR FINISH REQUIREMENTS.
10 INFILL WITH PARTITION TYPE S3-010.
11 INFILL EXISTING WALL OPENING WITH PARTITION TYPE S3-010 WHERE
DOOR IS REMOVED AT EXISTING SPRINKLER STATION. INSTALL NEW FEC
E7
A501B
E9
A501B
F3
A501B
NEW WORK PLAN GENERAL NOTES
1. TUNNEL INDICATED ON PLAN AS THUS:
2. FOR WALL PROTECTION PANELING ELEVATION, SEE
REFER TO FOR INSTALLATION LOCATION.
3. MODIFY EXISTING VINYL COMPOSITION TILE TO
EXTEND TILE TO CENTERLINE OF DOORS IN SCOPE
4. REMOVE SURFACE MOUNTED ELECTRICAL BOXES /
CONDUIT / FIXTURES AT WALLS WITHIN SCOPE
INFILL WALL TO MATCH EXISTING WALL TYPE. SEE FINISH SCHEDULE FOR
NEW FINISHES.
E6
A501B/F6 I101B
SHOWER PAN RECEPTOR BY GENERAL TRADE. SEE DETAILS ON SHEET
A501B
13 REPAINT DOOR AND FRAME
14 MODIFY EXISTING VINYL COMPOSITION TILE TO EXTEND TILE TO
CENTERLINE OF DOORS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
UPGRADE AHU 09 & LOCKER ROOM
OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
ARCHITECT/ENGINEER
310 Pine Street | Green Bay, WI 54301 920-432-4865 | www.berners-schober.com
BID DOCUMENTS
FULLY SPRINKLERED
KEY PLAN:
Comm. Number: 5700.05
OCTOBER 8, 2018
585-17-111
U.S. Department of Veterans Affairs
C U s e rs \j p o g ra n t\ D o c u m e n ts
\O G
J M
C
C E
N T
R A
L A
R C
H jp o g ra n t.
rv t
/1
/2
:5
:2
P M
Checker Author
A101B
BASEMENT FLOOR - NEW WORK PLAN
DWG. 3 OF 28
N
1/8" = 1'-0"
BASEMENT FLOOR - NEW WORK PLAN
F9
Revisions: Date:
SCHEMATIC DESIGN 03/15/2018
SP
F
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
F
OS
2U
OS
1U
OS
2U
OS
2U
OS
1U
OS
2U
OS
2U
OS
1U
EX
B299D-1
B299D-2
B299B-1
B299C-1
B226
B230
B231
B228 B228A
B228B
B228C
ACT
8' - 0"
ACT
8' - 0"
ACT
8' - 0"
ACT
8' - 0"
GYP
8' - 0"
EP1
ACT
8' - 0"
ACT
8' - 0"
ACT
8' - 0"
ACT
8' - 0"
ACT
8' - 0"
E4
AR101B
GYP
7' - 0"
EP1
GYP
8' - 0"
EP1
F4
AR101B
B299B-1
B3
ACT
8' - 0"
ACT
8' - 0"
GYP
7' - 4"
1'-6" D4
AR101B
F3
A501B
F3
A501B
WHERE EXISTING PARTITIONS ARE SHOWN TO HAVE A FIRE OR SMOKE RATING,
THE CONTRACTOR SHALL PROVIDE THE REQUIRED PENETRATION PROTECTION
FOR ALL NEW PENETRATIONS THROUGH THE PARTITION. REPORT ANY EXISTING
VOIDS WHICH REQUIRE PATCHING, UNDER ADDITIONAL SCOPE OF WORK.
CONTRACT WORK INCLUDES ALL CEILING MOUNTED ITEMS OR DEVICES
SHOWN ON THIS PLAN AND AS SHOWN ON THE PLANS OF OTHER TRADES.
THIS DRAWING DOES NOT RELIEVE CONTRACTOR'S RESPONSIBILITY TO
INDIVIDUALLY COORDINATE THEIR WORK WITH OTHER TRADES.
THIS DESIGNATION ON REFLECTED CEILING PLANS
INDICATES LOCATION OF CUT CEILING TILES
REQUIRED TO CENTER GRID PATTERNS IN
CORRIDORS
SYMBOLS KEY
HVAC
FIRE PROTECTION
ARCHITECTURAL
ACCESS PANEL
RETURN GRILLE
SUPPLY DIFFUSER
RETURN GRILLE
SUPPLY DIFFUSER
GYPSUM BOARD CEILING
CUBICLE TRACK LOCATION
LOCATION OF CEILING
MOUNTED
EQUIPMENT SUPPORT
AP
PAINTED SHEET METAL PANELP.
CONCEALED PENDENT SPRINKLER HEAD
CEILING COORDINATION PLAN LEGEND
EXHAUST GRILLE
SUPPLY DIFFUSER
PENDENT SPRINKLER HEAD
T
OS
LS
S
S
H
S
S
M
N
N
N
X
ER
MD
Z
F
2X4 LIGHT FIXTURE -
RECESSED / SURFACE
DUPLEX RECEPT / TELEVISION OUTLET
COMBINATION
RECESSED DOWNLIGHT,
SURFACE / PENDANT
1X4 LIGHT FIXTURE -
RECESSED / SURFACE
EXIT SIGN - SINGLE / DOUBLE FACE
TRACK LIGHTING
EMERGENCY BATTERY PACK
OCCUPANCY SENSOR
LIGHT SENSOR
WARNING LIGHT - CEILING
RECESSED CEILING SPEAKER
CEILING MOUNTED SPEAKER / STROBE
SMOKE DETECTOR
SMOKE DETECTOR FOR ELEVATOR
CONTROL
THERMAL DETECTOR
SPEAKER RECESSED
SPEAKER SURFACE
CEILING MOUNTED MIC JACK
ANTENNA
WIRELESS DATA ACCESS POINT
CEILING MOUNTED SPECIAL PURPOSE
CONNECTION
MOTION DETECTOR
CEILING MOUNTED SECURITY CAMERA
CORRIDOR DOME LIGHT
CORRIDOR ZONE LIGHT
CORRIDOR DOME LIGHT, FULL FEATURE
REMOTE LOCATOR RECEIVER
ELECTRICAL
2X2 LIGHT FIXTURE -
RECESSED / SURFACE
RTS/I REMOTE TEST SWITCH W/ INDICATOR
CEILING MOUNTED SECURITY CAMERA
(DOME TYPE)
CEILING MOUNTED RECEPTACLE
CEILING MOUNTED DATA / VOICE OUTLET
H CEILING MOUNTED HORN / STROBE
C CEILING MOUNTED CHIME / STROBE
S
S
EXHAUST GRILLE
ACOUSTICAL TILE
SWAY BRACE
AS REQUIRED
5/8" MOLD AND MOISTURE
RESISTANT GYPSUM BOARD
PROVIDE NEW LINTEL AS/IF REQUIRED. FEILD
VERIFY AND COORDINATE WITH ARCHITECT
PRIOR TO WALL REMOVAL.
PATCH TO MATCH EXISTING WALL.
REMOVE EXISTING WALL ABOVE DOOR TO
HEIGHT REQUIRED TO ALLOW FOR BULKHEAD.
REMOVE EXISTING DOOR AND FRAME.
PATCH FOR CASED OPENING.
(M
IN
EXISTING WALL
ACOUSTICAL TILE
SEE PLAN FOR
CEILING HEIGHT.
STAIR, SHAFT, OR HAZARDOUS AREA SEPARATION
WALLS: 2 HOUR FIRE
DOORS: 90 MINUTE FIRE
OPENINGS: NOT PERMITTED
DAMPERS: 90 MINUTE FIRE
FIRE COMPARTMENT DIVISON
WALLS: 2 HOUR FIRE AND SMOKE RESISTANT
DOORS: 90 MINUTE FIRE AND SMOKE RESISTANT
OPENINGS: NOT PERMITTED
DAMPERS: 90 MINUTE FIRE AND SMOKE RESISTANT
STAIR, SHAFT, OR HAZARDOUS AREA SEPARATION
WALLS: 1 HOUR FIRE
DOORS: 45 MINUTE FIRE
OPENINGS: 45 MINUTE PROTECTION
DAMPERS: 90 MINUTE FIRE AT NON-SPRINKLED
SMOKE COMPARTMENT DIVISON
WALLS: 1 HOUR FIRE AND SMOKE RESISTANT
DOORS: 20 MINUTE CONSTRUCTION AND SMOKE RESISTANT
OPENINGS: 20 MINUTE PROTECTION,
45 MINUTE AT 1 HOUR RATED ROOMS
DAMPERS: SMOKE RESISTANT
(IN NEW CONSTRUCTION REQUIRED BY IBC)
ONE HOUR SMOKE RESISTANT PARTITION
(NON-SPRINKLED COMPARTEMENT)
WALLS: 1 HOUR FIRE AND SMOKE RESISTANT
DOORS: 20 MINUTE CONSTRUCTION AND SMOKE RESISTANT
OPENINGS: 20 MINUTE PROTECTION
SMOKE RESISTANT PARTITION (SPRINKLED COMPARTMENT)
WALLS: SMOKE RESISTANT
DOORS: SMOKE RESISTANT AND POSITIVE LATCHING,
(EXCEPT TOILET ROOMS, ECT.)
OPENINGS: CANNOT EXCEED 80 SQ. IN. WITHOUT PROTECTION
FIRE SEPARATION LEGEND
REFLECTED CEILING PLAN KEYED NOTES
PATCH CEILING AS REQUIRED. MATCH WITH EXISTING CEILING GRID.
MODIFY EXISTING CEILING WHERE WALL SURFACE IS FLUSHED OUT.
ACOUSTICAL
TILE
3 5/8" METAL
STUDS
SWAY BRACE
AS REQUIRED
5/8" MOLD AND
MOISTURE
RESISTANT
GYPSUM BOARD
CEILING HEIGHTS MEASURED TO
GRID (VARIES - SEE ARCHITECTURAL
REFLECTED CEILING PLAN)
(M
IN
5/8" GYPSUM
BOARD
ACOUSTICAL
TILE
3 5/8" METAL
STUDS
CEILING HEIGHTS MEASURED TO
GRID (VARIES - SEE ARCHITECTURAL
REFLECTED CEILING PLAN)
SEE
REFLECTED
CEILING PLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
UPGRADE AHU 09 & LOCKER ROOM
OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
ARCHITECT/ENGINEER
310 Pine Street | Green Bay, WI 54301 920-432-4865 | www.berners-schober.com
BID DOCUMENTS
FULLY SPRINKLERED
KEY PLAN:
Comm. Number: 5700.05
OCTOBER 8, 2018
585-17-111
U.S. Department of Veterans Affairs
C U s e rs \j p o g ra n t\ D o c u m e n ts
\O G
J M
C
C E
N T
R A
L A
R C
H jp o g ra n t.
rv t
/1
/2
:5
:5
P M
Checker Author
AR101B
BASEMENT - REFLECTED CEILING
PLAN
DWG. 4 OF 28
N
1/8" = 1'-0"
BASEMENT - REFLECTED CEILING PLAN
F6
1 1/2" = 1'-0" F4
CEILING DROP
1 1/2" = 1'-0" E4
CEILING TRANSITION
1 1/2" = 1'-0" D4
CEILING DROP
Revisions: Date:
SCHEMATIC DESIGN 03/15/2018
ALL SINGLE
TIER LOCKERS
335 SF
MENS
LOCKER
B228B
360 SF
MENS
SHOWER
B228C
B E
N C
H
A401BE7
A401B
E5
B E
N C
H
TOWELS / HAMPER
A401B
F7
F6
12" DIA. FINISHED
TOWEL DROP HOLE
WITH EASED EDGE
/8
6'-0"
PT-1
E
SD-1
SD-1
M-1
M-1
M-1
E
E
7'-4" 5'-6" 7'-8"
CH-1
CH-1
TB-1
TB-1
A401B F4
F5
/2
/8
SS-1
GB-18
G B
-4
G B
-3
GB-42
GB-18
5"
TD-2E
TD-2
TD-2
E
E
/8
3'-0" 7'-11"
T Y
P
/2
3'-0"
F1
A701B
TYP.
LOCKER
BASE
M-1M-1M-1
CH-1CH-1 CH-1CH-1
SD-1 SD-1
E E
F6
A701B
PT-1
E
HCB
COORDINATE HCB WITH SINK LOCATIONS
8'-3 1/2"
HCB HCB
KS KS KS
17" TO RIM
SS1
PL1
D
A401B C7
UNISEX
BREAKROOM
B228
C5
TV E
SYSTEM
CLOCK
CG1
SD-1
PT-1
E
E
REF.
E
MICROWAVEE
COFFEE
MAKER
MICROWAVE
E
E
REF.
E
F
3'-0"
SD-1
PT-1
E
E
27" 34"
18" 24"36" 24"36" 24"
E
COFFEE
MAKER
E MICRO
MICROE
27" 34"
F6
A701B
F5
A701B
PL1
PL1
SS2D
CH-1(7)
F1
A701B
--------------LOCKER
BASE
CG1CG1 CG1
HAMPER
TOWEL STORAGE
21" 84"36" 34"
12" DIA. FINISHED
TOWEL DROP HOLE
WITH EASED EDGE
OPEN
BASE
F4
A701B
F7
A701B
PL1
SS1 D
OPEN
24" 84" FF
18" DEEP
CABINET
TV
E
COORDINATE TV
LOCATION WITH OWNER
PT-1
E
CG1
3'-0"
TB-1
GB-18
SR-1
SS-1
GB-42
SR-1
E
M-1
MIRROR (CC)
D-1
SOAP DISH (CC)
PT-1
SOAP DISPENSER (VC)
PAPER TOWEL
DISPENSER
(VC)
GB-36
GRAB BAR REAR WALL (CC) GRAB BAR SIDE WALL (CC)
GB-42
GB-18
18"
T O
H
IG
H E
S T
C
O N
T R
O L
T O
H
IG
H E
S
C
O N
T R
O L
36"
12"
MIN.
42"
54"
12"
40"
/4
/4
AT CONCRETE BLOCK
CHASE WALLS, PROVIDE
16" X 16" OPENING WITH
1/4" X 4" PLATE LINTEL IN
FIXTURE WALL ABOVE
CEILING FOR VISUAL
INSPECTION INSIDE CHASE
ACCESSIBLE CLEARANCE SPACE.
EXCEPT OTHER GRAB BARS, SHOWER
CONTROLS AND OTHER PLUMBING
CONTROLS, NO ITEMS SHALL BE
PROTRUDING INTO THIS SPACE.
IC
C
/A N
S I
M
IN
P
E R
ESD-1
M A
X
.3
CH-1
CLOTHES HOOK (CC)
TOWEL BAR (CC)
TB-1
1'-6"
ACCESSIBLE ROLL-IN SHOWER ELEVATION
[SOAP DISPENSER
OR DISH]
27" MAX.
CONTROL
REACH RANGE
HORIZONTAL GRAB BAR
SLIDE BAR FOR
HAND-HELD SHOWER
SHOWER SEAT
24"6" MAX
ACCESSIBILITY STANDARD CLEARANCE
SPACE. EXCEPT OTHER GRAB BARS,
SHOWER CONTROLS AND OTHER
PLUMBING CONTROLS, NO ITEMS SHALL
BE PROTRUDING INTO THIS SPACE.
ACCESSIBLE SHOWER SEAT
SS-1
ACCESSIBLE SHOWER SEAT (CC)
3'-1"
1 1/2" MAX.3" MAX.
SHOWER
ENTRANCE
15" MIN. - 16" MAX.
22" MIN. - 23" MAX.
EQUIPMENT DESIGNATION AS FOLLOWS (UNO)
VV - VA PROVIDED VA INSTALLED
VC - VA PROVIDED CONTRACTOR INSTALLED
CC - CONTACTOR PROVIDED CONTRACTOR INSTALLED
SR-1
SHOWER ROD (CC)
(V E
R
IF
Y
DOUBLE ROLL TOILET
TISSUE DISPENSER
(VC)
TD-22
8"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
UPGRADE AHU 09 & LOCKER ROOM
OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
ARCHITECT/ENGINEER
310 Pine Street | Green Bay, WI 54301 920-432-4865 | www.berners-schober.com
BID DOCUMENTS
FULLY SPRINKLERED
Comm. Number: 5700.05
OCTOBER 8, 2018
585-17-111
U.S. Department of Veterans Affairs
C U s e rs \j p o g ra n t\ D o c u m e n ts
\O G
J M
C
C E
N T
R A
L A
R C
H jp o g ra n t.
rv t
/1
/2
:5
:2
P M
Checker Author
A401B
ENLARGED PLANS AND ELEVATIONS
DWG. 5 OF 28
N
1/4" = 1'-0"
MENS SHOWER/LOCKERS
F8
1/4" = 1'-0" E7
MENS SHOWER/LOCKERS - WEST ELEV.
N
1/4" = 1'-0"
UNISEX BREAKROOM
C9
1/4" = 1'-0" C7
BREAKROOM - EAST ELEV.
1/4" = 1'-0" E5
MENS LOCKERS - NORTH ELEV.
1/4" = 1'-0" F7
LOCKER VEST. - NORTH ELEV.
1/4" = 1'-0" C5
BREAKROOM - WEST ELEV.
1/4" = 1'-0" F6
MENS SHOWER - SOUTH ELEV.
1/4" = 1'-0"
F5
MENS SHOWER - NORTH ELEV.
1/4" = 1'-0" F4
MENS SHOWER - EAST ELEV.
3/8" = 1'-0" B1
ACCESSORY SCHEDULE AND MOUNTING HEIGHTS
Revisions: Date:
SPECIAL
VERTICAL BLOCKING
STANDARD
HORIZONTAL BLOCKING
WOOD
BLOCKING
METAL
STUDS
SAWCUT
BLOCKING TO
RECEIVE METAL
STUD FLANGE
USE WHERE ITEM BEING
MOUNTED EXERTS A
DOWNWARD TWISTING
FORCE
(FOLDING COUNTER
BRACKETS, TV BRACKETS,
ETC.)
USE WHERE ITEM BEING
MOUNTED DOES NOT
EXERT A DOWNWARD
FORCE (CABINETS,
GRAB
BARS, VIEW BOXES,
MARKER BOARDS ETC.)
1 1 /2
H E
IG
H
T
T O
S U
IT
'-0
M
IN
IM
U
M
/2
11 1/4" TYP.
NOTE:
FIRETREATED 2X12
BLOCKING, TYPICAL
1'-0"1'-0"
PARTITION
SHOWN ON
PLAN TO BE
REMOVED
SCHEDULED
FLOOR FINISH
LEVEL EXISTING
FLOOR TO WITHIN
1/8"
IN 5'-0"
CONCRETE INFILL
EXISTING SLAB
TERRAZZO
OR CONC.
TERRAZZO
OR CONC.
LATEX OR GRIND
AS REQUIRED
.2
RESILIENT SHEET
METAL EDGE
PROTECTOR
PORCELAIN TILE
V E
R
/8
G. RESILIENT SHEET / PORCELAIN TILE
RESILIENT TILE RESILIENT SHEET
LATEX FLOOR FOR FLUSH
TRANSITION (NO REDUCER STRIP)
C. RESILIENT TILE / RESILIENT SHEET
S
WHERE (2) STUD MOUNTED
DEVICES ARE SCHEDULED,
ALIGN HEIGHTS OF
FINISHED PRODUCT.
WHERE MULTIPLE DEVICES
ARE SCHEDULED TO
OCCUR WITHIN 16" OF
EACH OTHER, ALIGN
DEVICES ON (1) FACE OF STUD
STUDS
DOOR
WHERE MULTIPLE DEVICES ARE SCHEDULED,
ALONG A DOOR, DEVICES SHALL BE ALIGNED ON
(1) FACE OF METAL STUD AND SHALL OCCUR AT
SWING/ LATCH SIDE OF DOOR. EXC THERMOSTATS
ROOM
CORRIDOR
WHERE MULTIPLE DEVICES
ARE SCHEDULED IN CLOSE
PROXIMITY IN HEIGHT,
ALIGN DEVICES.
POSITION ROOM THERMOSTAT ADJACENT TO
LIGHT SWITCH. ALIGN TOP OF THERMOSTAT
WITH LIGHT SWITCH COVER PLATE
WHERE MULTIPLE DEVICES ARE SCHEDULED IN
CLOSE PROXIMITY IN HEIGHT, ALIGN DEVICES.
T O
T O
P
SHOWER PAN
RECEPTOR BY
GENERAL TRADE
CBU GRADE
CEMENT BOARD
VAPOR RETARDER,
LAP OVER CLEAVAGE
MEMBRANE
FLOOR LINE
CLEAVAGE
MEMBRANE
REINFORCING
MORTAR
BED
VERIFY DIMENSIONS
ON SITE
1/2" SEALANT BEAD
BY SHOWER PAN
MANUFACTUER
WALL PANEL BY SHOWER
PAN MANUFACTUER
3 5/8" METAL STUDS
5/8" MOLD AND MOISTURE
RESISTANT GYPSUM BOARD
VAPOR RETARDER (SHOWN
DASHED) TAPE JOINTS AND TAPE TO
UNDERSIDE OF STRUCTURE ABOVE
(TYPICAL)
ADHERE MEMBRANE
TO SHOWER PAN
MORTAR BED
SEALANT JOINT BETWEEN
TILE AND SHOWER PAN
REINFORCING
REINFORCING
TILE AS SCHEDULED
CEMENTITIOUS
BOND COAT
UNBONDED MORTAR BED
CLEAVAGE MEMBRANE
VERIFY DIMENSIONS
ON SITE
CORNER BEYOND OR END
OF SHOWER PANELS
C7
A501B
TRANSITION AT TILE
TILE AS
SCHEDULED
EXTRUDED
ALUMINUM TRIM WALL PANEL WITH
FINISHED END BY
SHOWER PAN
MANUFACTURER
TRANSITION ABOVE TILE
BEAD OF CAULK ALONG
EDGE BY SHOWER PAN
MANUFACTURER
CAULK JOINT
WALL PANEL WITH
FINISHED END BY
SHOWER PAN
MANUFACTURER
BEAD OF CAULK ALONG
EDGE BY SHOWER PAN
MANUFACTURER
MOLD AND MOISTURE
RESISTANT GYPSUM
BOARD
PAN BELOW
PAN BELOW
WALL PANEL WITH
FINISHED END BY
SHOWER PAN
MANUFACTURER
BEAD OF CAULK ALONG
EDGE BY SHOWER PAN
MANUFACTURER
TILE AS
SCHEDULED
EXTRUDED
ALUMINUM TRIM
CAULK JOINT
PAN BELOW
TRANSITION AT TILE
WALL PANEL WITH
FINISHED END BY
SHOWER PAN
MANUFACTURER
BEAD OF CAULK ALONG
EDGE BY SHOWER PAN
MANUFACTURER
PAN BELOW
TRANSITION AT TILE
VERIFY IN FEILD
6 # 3 X 2'-4"" LONG EQUALLY
SPACED AROUND EXISTING
OPENING - 4" EMBEDMENT
INTO EXISTING SLAB
TERRAZZO
OR CONC.
TERRAZZO
OR CONC.
V E
R
IF
Y
4"
TYPICAL SILL
JAMB
3/4"
M
IN
/2
EASED EDGE
REMOVE EXISTING
FURRING WALL
FINISHED FACE OF TILE
EXTEND SILL BEYOND
WINDOW JAMB WHERE
APPLICABLE
BACKER ROD AND URETHANE SEALANT
EXISTING WINDOW SYSTEM
VERIFY ON SITE TOTAL
DEPTH OF WINDOW SILL
+/- 7"
1/2" SOLID SURFACE SILL. SHIM AS REQUIRED.
1 5/8" METAL STUD
5/8" GYPSUM BOARD
MODIFY EXISTING WINDOW FRAME AS REQUIRED
TO ACCOMMODATE NEW CONSTRUCTION
WRAP GYPSUM BOARD TO
WINDOW FRAME AT JAMB
BLOCKING
SWAY BRACE
AS REQUIRED
TYPICAL HEAD
SOFFIT HEIGHT VARIES - SEE
ARCHITECTURAL REFLECTED
CEILING PLAN
3 5/8" METAL
STUDS
5/8" GYPSUM
BOARD
3" 1'-1"
VERIFY IN FIELD
V A
R
IE
S
S E
E P
L A
N
ACOUSTICAL
TILE
BACKER ROD AND
URETHANE SEALANT
EXISTING WINDOW
SYSTEM
VERIFY EXISTING WINDOW CONDITIONS IN FIELD
M A
T C
H H
E
IG
H T
O F
E X
IS
T
IN
G
/2
4" VERIFY ON SITE 2"
1/2" PANEL - SWP2
1/2" PANEL - SWP2
RUBBER BASE
/8
P
A N
E L
S W
P
/8
P
A N
E L
S W
P
SHEET WALL PROTECTION
ON 5/8" GYPSUM BOARD
AT INSIDE AND
OUTSIDE CORNERS
HANDRAIL
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
UPGRADE AHU 09 & LOCKER ROOM
OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
ARCHITECT/ENGINEER
310 Pine Street | Green Bay, WI 54301 920-432-4865 | www.berners-schober.com
BID DOCUMENTS
FULLY SPRINKLERED
Comm. Number: 5700.05
OCTOBER 8, 2018
585-17-111
U.S. Department of Veterans Affairs
C U s e rs \j p o g ra n t\ D o c u m e n ts
\O G
J M
C
C E
N T
R A
L A
R C
H jp o g ra n t.
rv t
/1
/2
:5
:3
P M
Checker Author
A501B
MISCELLANEOUS DETAILS
DWG. 6 OF 28
1" = 1'-0" F9
WOOD BLOCKING ISOMETRIC
1 1/2" = 1'-0" E9
TOPPING INFILL
12" = 1'-0" F6
FLOOR TRANSITIONS
1/4" = 1'-0"
F7
DEVICE MOUNTING SCHEDULE
3" = 1'-0" D9
SHOWER PAN EDGE
3" = 1'-0"
D7
SHOWER ACCESSABLE THRESHOLD
3" = 1'-0" C7
SHOWER DETAILS
1 1/2" = 1'-0" E7
TUNNEL INFILL
3" = 1'-0" F3
WINDOW SILL
1" = 1'-0" E6
CORRIDOR PANELING
Revisions: Date:
WIDTH
4" MINIMUM AT ACOUSTICAL
TILE CEILINGS
WALL FURRING BRACKETS
AT 48" O.C. ABOVE FLOOR
(1) LAYER 5/8" GYPSUM
BOARD
SURFACE TO BE FURRED
F1-010 3" N/AN/A1 5/8" METAL STUDS
EXTEND GYPSUM BOARD AND
STUDS TO STRUCTURE ABOVE
WHERE NO CEILING OCCURS
WIDTH STCWALL STRUCTURETYPE RATING/TEST
CEILING TYPE AS SCHEDULED
WIDTH
S3A110 4 7/8" 44/39*3 5/8" METAL STUDS N/A
WIDTH STCWALL STRUCTURETYPE RATING/TEST
3" ACOUSTIC INSULATION
PER UL ASSEMBLY AT
RATED PARTITIONS.
(6" AT 6" METAL STUDS)
(1) LAYER 5/8" GYPSUM
BOARD EACH SIDE TO
STRUCTURE ABOVE
ACOUSTICAL SEALANT
AT NON-RATED WALLS
CEILING TYPE AS
SCHEDULED
FIRE STOPPING AT
RATED PARTITIONS
3" ACOUSTIC
INSULATION.
(6" AT 6" METAL STUDS)
* DENOTES 20 GA. METAL STUDS
WIDTH
CEILING TYPE AS
SCHEDULED
3" ACOUSTIC INSULATION
PER UL ASSEMBLY AT
RATED PARTITIONS.
(6" AT 6" METAL STUDS)
FIRE STOPPING
3" ACOUSTIC INSULATION.
(6" AT 6" METAL STUDS)
(2) LAYERS 5/8" GYPSUM
BOARD EACH SIDE TO
STRUCTURE ABOVE
S3A222 6 1/8" 53/43*3 5/8" METAL STUDS
WIDTH STCWALL STRUCTURETYPE RATING/TEST
* DENOTES 20 GA. METAL STUDS
2 HR U.L. U411
WIDTH
(2) LAYERS 5/8" GYPSUM
BOARD
CEILING TYPE AS SCHEDULED
1" GYPSUM SHAFT LINER
PANEL. INDICATED AS "0"
ON PARTITION SYMBOL
1" ACOUSTIC INSULATION
PER UL ASSEMBLY
(3" AT 4" C-H METAL STUDS)
(6" AT 6" C-H METAL STUDS
FIRE STOPPING
U2A022 3 3/4" 462 HR U.L. U4152 1/2" C-H METAL STUDS
WIDTH STCWALL STRUCTURETYPE RATING/TEST
4" MINIMUM AT ACOUSTICAL
TILE CEILINGS
SURFACE TO BE FURRED
CEILING TYPE AS SCHEDULED
EXTEND GYPSUM BOARD AND
CHANNELS TO STRUCTURE ABOVE
WHERE NO CEILING OCCURS
F0-010 1 1/2" N/AN/A7/8" HAT CHANNELS
TYPE
WIDTH
WIDTH STCWALL STRUCTURETYPE RATING/TEST
(1) LAYER 5/8" GYPSUM BOARD
7/8" METAL FURRING
CHANNELS
(UNLESS NOTED OTHERWISE):
GENERAL INTERNAL PARTITION NOTES
(UNLESS NOTED OTHERWISE):
STANDARD PARTITION TYPES
1. INTERIOR GYPSUM BOARD SHALL BE AS LISTED IN THE ORDER
OF IMPORTANCE AS FOLLOWS
A. AT FIRE RATED PARTITIONS, GYPSUM BOARD SHALL
COMPLY WITH THE INDICATED UL DESIGN NUMBER OR
OTHER SIMILAR THIRD PARTY TESTED ASSEMBLY.
B. AS LISTED IN THE TILE COUNCIL OF NORTH AMERICA
(TCNA) NUMBER AS INDICATED IN SPECIFICATION
1. GLASS MESH CEMENT BOARD TILE BACKER MATERIAL
AT ALL WALLS AND CEILINGS OF TOILET ROOMS WITH
SHOWERS. PROVIDE MOLD AND MOISTURE RESISTANT
TYPE "X" GYPSUM BOARD ABOVE TILE TO HEIGHT
SHOWN ON DRAWINGS.
C. PROVIDE MOLD AND MOISTURE RESISTANT TYPE "X"
GYPSUM BOARD AT THE FOLLOWING LOCATIONS:
1. ALL WALLS AND CEILINGS OF TOILET ROOMS (SEE
NOTE B FOR CONDITIONS AT TILE).
2. JAMBS AND HEADS OF WINDOWS AND EXTERIOR DOOR
OPENINGS.
3. 4'-0" MINIMUM ALL SIDES OF THE CENTER LINE OF
PLUMBING FIXTURES.
D. ALL GYPSUM BOARD SHALL BE TYPE "X" IMPACT
RESISTANT.
2. ALL DIMENSIONS LOCATING INTERIOR PARTITIONS ARE TO
FACE OF CONCRETE BLOCK, OR FACE OF OUTER LAYER OF
GYPSUM BOARD. DIMENSIONS ON PLANS IGNORE APPLIED
FINISHES.
3. FOR PARTITION PRIORITY CONSTRUCTION LEGEND SEE:
4. FOR HEAD OF WALL CONDITION AT NON RATED GYPSUM
BOARD AND METAL STUD PARTITIONS SEE:
5. WHERE RATED WALL ASSEMBLIES ARE INDICATED, THE
CONTRACTOR SHALL PROVIDE UL LISTED JOINT SYSTEMS FOR
THE FOLLOWING:
A. HEAD OF WALL (ALLOW FOR 1/2" MINIMUM OF MOVEMENT
EXTENSION OR COMPRESSION IN EACH DIRECTION).
B. BOTTOM OF WALL
C. WALL TO WALL
D. FLOOR TO WALL
E. FLOOR TO FLOOR
F. ANY PENETRATION OR OTHER JOINT SYSTEM WITHIN OR
AT TERMINATION OF RATED WALL.
6. WHERE MECHANICAL EQUIPMENT DOES NOT ALLOW STUDS TO
EXTEND TO STRUCTURE, PROVIDE STRUCTURAL METAL STUD
BOX HEADER BENEATH ALL MECHANICAL EQUIPMENT. BOX
HEADER SHALL BE CONSTRUCTED OF (2) STRUCTURAL STUDS
LAID ON THEIR BACK SIDE UTILIZING THE SAME DIMENSION
STUDS AS THE WALL BEING CONSTRUCTED (I.E. 3 5/8").
OPENINGS BETWEEN 8'-0" AND 12'-0" SHALL UTILIZE
MINIMUM .0451 THICKNESS STUDS. OPENINGS LESS THAN 8'-0"
SHALL UTILIZE .0346 THICKNESS STUDS.
7. GYPSUM BOARD MAY BE OMITTED ON NON-ACCESSIBLE SIDES
OF NON-FIRE RATED PARTITIONS.
8. FOR CERAMIC TILE WALL CONSTRUCTION SEE
1. ALL SINGLE LAYER GYPSUM BOARD PARTITIONS SHALL BE
TYPE S3A110. INDICATED ON PLANS AS THUS
2. ALL DOUBLE LAYER GYPSUM BOARD PARTITIONS SHALL BE
TYPE S3A220. INDICATED ON PLANS AS THUS
3. SINGLE LAYER GYPSUM BOARD PARTITIONS USED AS COLUMN
FURRING AT INTERIOR COLUMNS SHALL BE TYPE F1-010.
4. DOUBLE LAYER GYPSUM BOARD PARTITIONS USED AS COLUMN
FURRING AT INTERIOR COLUMNS SHALL BE TYPE F1-020.
D7
A601B
B5
A601B
B6
A601B
SCHEDULE
SEE
S E
E S
C H
E D
U L E
A
(2) METAL
STUDS AT JAMB
SCHEDULE
SEE PARTITION
/8
1 15/16" VARIES
MANUFACTURER'S
STANDARD
AT DOOR
SIDE
(3) ANCHORS
PER JAMB
MINIMUM
MINIMUM 7/16"
BACKBEND
EACH SIDE
SOLIDLY PACK
HEAD AND JAMBS
WITH MINERAL
FIBER INSULATION
BEHIND FRAME
J1
S E
E S
C H
E D
U L E
SCHEDULE
SEE2" 2"
HF-1
S E
E S
C H
E D
U L E
SCHEDULE
SEE2" 2"
(2) DOORS
HF-2
GENERAL PARTITION NOTES
TWO HOUR FIRE AND / OR SMOKE PARTITION (HIGHEST) = PRIORITY 1
TWO HOUR FIRE WALL = PRIORITY 2
TWO HOUR SHAFT WALL = PRIORITY 2
ONE HOUR FIRE AND / OR SMOKE PARTITION = PRIORITY 3
ONE HOUR FIRE WALL = PRIORITY 4
NON-RATED PARTITION (LOWEST) = PRIORITY 5
NOTE:
ALL PARITION TYPES LISTED MAY NOT BE USED, REFER TO PLANS.
HOLLOW METAL FRAME
(AS APPLICABLE)
ONE HOUR
CONSTRUCTION
TWO HOUR FIRE AND /
OR SMOKE PARTITION
CONSTRUCTION
METAL STUDS
(TYPICAL)
RATED WALL
AND / OR SMOKE
PARTITION
NON-RATED
PARTITION
(LOWEST
PRIORITY)
TWO HOUR FIRE AND /
OR SMOKE PARTITION
CONSTRUCTION
NON-RATED PARTITION
(LOWEST PRIORITY)
U2-022
SHAFTWALL
(PRIORITY 1)
NON-RATED
PARTITION
CHASE
RATED
WALL
RATED
SHAFT
WALL
OUTSIDE CORNER
INSIDE CORNER
DEEP LEG TRACK
(2" MINIMUM)
METAL STUDS CUT 1" LESS IN
HEIGHT THAN ASSEMBLY
PROVIDE TEMPORARY MEANS
OF SUPPORTING STUDS IN
VERTICAL POSITION WITHOUT
SECURING STUDS TO TOP
TRACK
CONDITION AT FLAT SLAB PARALLEL
WITH JOISTS, BOTTOM OF JOISTS, AND
TILE AND JOIST SYSTEMS
ATTACH GYPSUM
BOARD TO METAL
STUDS TO ALLOW
FOR MOVEMENT.
OF STUDS IN
DEEP LEG TRACK
1/2" ACOUSTICAL SEALANT
JOINT TYPICAL WHERE
GYPSUM BOARD MEETS
BOTTOM OF SLAB ON
PERIMETER AT JOISTS
CONDITION AT WALLS
PERPENDICULAR TO JOISTS
SCHEDULED
PARTITION AS
SEE SPECIFICATION
FOR TYPE OF
CONNECTION TO
STRUCTURE ABOVE
EXISTING
STRUCTURE
PROVIDE TEMPORARY MEANS OF
SUPPORTING STUDS IN VERTICAL
POSITION WITHOUT SECURING
STUDS TO TOP TRACK
METAL STUDS CUT 1" LESS IN
HEIGHT THAN ASSEMBLY
DEEP LEG TRACK (2" MINIMUM)
ATTACH TO BOTTOM OF JOIST
1" ACOUSTICAL SEALANT JOINT.
VERIFY JOINT SIZE WITH
MANUFACTURER MOVEMENT ABILITY.
ATTACH GYPSUM
BOARD TO METAL
STUDS TO ALLOW
FOR MOVEMENT
OF STUDS IN
DEEP LEG TRACK.
SEE SPECIFICATION
FOR TYPE OF
CONNECTION TO
STRUCTURE
ABOVE.
BOTTOM OF JOISTS
1" ACOUSTICAL SEALANT
JOINT. VERIFY JOINT SIZE
WITH MANUFACTURER
MOVEMENT ABILITY.
TILE BACKER
MATERIAL AS
REQUIRED PER TILE
COUNCIL OF NORTH
AMERICA (TCNA)
REFERENCE NUMBER.
REINFORCING
TILE AS SCHEDULED
CEMENTITIOUS
BOND COAT
UNBONDED MORTAR BED
CLEAVAGE MEMBRANE
STRUCTURAL SLAB
FULL HEIGHT TILE OR
WAINSCOT AS SCHEDULED
BOND COAT
MOLD AND MOISTURE
RESISTANT GYPSUM
BOARD
SEALANT
V E
R
IF
Y
MINIMUM 20 GAUGE (0.033") OR
HEAVIER 3 5/8" METAL STUDS
CONDITION ADJACENT TO SHOWER - REFERENCE TCNA NO. W244C, F121
(ENVIRONMENTAL CLASSIFICATION COM 2)
SINGLE LAYER CONSTRUTION
NO VAPOR RETARDER
REQUIRED AT TOILET
ROOMS WITHOUT SHOWERS.
VAPOR RETARDER (SHOWN
DASHED) TAPE JOINTS AND TAPE
TO UNDERSIDE OF STRUCTURE
ABOVE (TYPICAL) AT PARTITIONS
ADJACENT TO SHOWERS.
EXTRUDED ALUMINUM TRIM
EXTRUDED ALUMINUM TRIM
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
UPGRADE AHU 09 & LOCKER ROOM
OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
ARCHITECT/ENGINEER
310 Pine Street | Green Bay, WI 54301 920-432-4865 | www.berners-schober.com
BID DOCUMENTS
FULLY SPRINKLERED
Comm. Number: 5700.05
OCTOBER 8, 2018
585-17-111
U.S. Department of Veterans Affairs
C U s e rs \j p o g ra n t\ D o c u m e n ts
\O G
J M
C
C E
N T
R A
L A
R C
H jp o g ra n t.
rv t
/1
/2
:5
:3
P M
Checker Author
A601B
SCHEDULES AND DETAILS
DWG. 7 OF 28
5700.05 - DOOR SCHEDULE
OPENING
NUMBER
DOORS FRAMES DETAILS
LABEL HARDWARE REMARKS REVISIONSELEVATION MATERIAL CORE WIDTH HEIGHT GLAZING ELEVATION MATERIAL GLAZING HEAD JAMB SILL
B228-1 A WOOD SOLID 42" 7' - 0" - HF-1 HOLLOW METAL - J1 J1 - - 1
B228-2 A WOOD SOLID 42" 7' - 0" - HF-1 HOLLOW METAL - J1 J1 - - 2
B228-3 A WOOD SOLID 36" 7' - 0" - HF-1 HOLLOW METAL - J1 J1 - - 2
B230 A WOOD SOLID 48" 7' - 0" - HF-1 HOLLOW METAL - J1 J1 - 90 MINUTE 3
B296 A WOOD SOLID 30" 7' - 0" - EXISTING - - - - - - 4 EXISTING DOOR FRAME TO REMAIN
B298-1 A WOOD SOLID 36" 7' - 0" - HF-2 HOLLOW METAL - J1 J1 - - 5
B298-2 A WOOD SOLID 36" 7' - 0" - HF-2 HOLLOW METAL - J1 J1 - - 5
1 1/2" = 1'-0" D5
PARTITION SCHEDULE
1/4" = 1'-0" F8
DOOR ELEVATIONS
3" = 1'-0"
F7
FRAME DETAILS
1/4" = 1'-0" F9
FRAME ELEVATIONS
1 1/2" = 1'-0" B6
PARTITION PRIORITY LEGEND
3" = 1'-0" D7
NON-RATED HEAD OF WALL
3" = 1'-0" B5
CERAMIC TILE CONDITIONS
ATTACH APRON TO END
PANELS WITH 1 1/2" X
1 1/2" X 3/16" ALUMINUM
CLIP ANGLES
KNEE SPACE
11" MIN.
17" MIN. TOE SPACE
REQUIRED
ACCESSIBLE
KNEE / TOE
SPACE SHOWN
CROSS HATCHED
KNEE SPACE
8" MIN.
3/4"
FIXED
APRON
/2
/2
25" UNLESS NOTED OTHERWISE
SECTION
1"
T O
E S
P A
C E
K N
E E
V A
R
IE
S
S E
E E
L E
V A
T
IO
N
ADJUSTABLE SHELF
FULL SUBTOP
MICROWAVE
PLASTIC LAMINATE CASEWORK LEGEND
F
F
EXAMPLE INDICATES
36"
36"
U
N L E
S S
N O
T E
D O
T H
E R
W
IS
E
WIDTH
HEIGHT
WIDTH
HEIGHT
BOTTOM OF
CABINET
1" FILLER
MIN. 3" MAX.
FILLER
FILLER
CASEWORK FINISH - SEE INTERIOR FINISH LEGEND
(PLAM1)
(SS1)
(PLAM1)
STANDARD PLASTIC LAMINATE CASEWORK NOTES
(UNLESS NOTED OTHERWISE)
REFER TO SHEET A401B FOR COUNTERTOP TYPES. SEE FOR DETAIL.
LIGHTS AND OUTLETS BY ELECTRICAL TRADE
FIELD VERIFY WALL TO WALL DIMENSIONS. COORDINATE DIMENSIONS PRIOR TO
CABINET FABRICATION. HIGHLIGHT ANY ADJUSTMENTS MADE TO CABINETS ON SHOP
DRAWINGS FOR APPROVAL.
ALL DIMENSIONS GIVEN AT CASEWORK ELEVATIONS ARE IN INDIVIDUAL UNIT
DIMENSIONS. NO VERTICAL DIVIDER PANELS SHALL OCCUR WITHIN ANY INDIVIDUAL
CASEWORK UNITS LESS THAN 42".
WOOD TRIM SHALL BE SOLID WOOD. REFERENCE ARCHITECTURAL SPECIFICATIONS
FOR QUALITY INFORMATION.
CABINET BODIES SHALL BE FINISHED PER BELOW (AS DEFINED BY AWS EDITION 1):
1. EXPOSED EXTERIOR - COLOR LISTED ON ELEVATIONS
2. EXPOSED INTERIOR - (INCLUDING WHERE CABINETS ARE DENOTED AS "OPEN"
EXCLUDING TOE SPACES) - COLOR LISTED ON ELEVATIONS.
3. SEMI-EXPOSED - WHITE MELAMINE.
4. CONCEALED - ONE COAT SEALER OR WHITE MELAMINE.
PROVIDE STAIN AND URETHANE SAMPLES ON ALL INDICATED SUBSTRATES WITH STAIN
COLOR FOR ARCHITECTS APPROVAL PRIOR TO ANY WORK.
COUNTERTOP BRACKET SHALL BE PAINTED TO MATCH ADJACENT CASEWORK COLOR
OR WALL COLOR.
SEE INTERIOR FINISH LEGEND FOR ADDITIONAL CASEWORK AND ACCESSORY
FINISHES.
ALL SINKS IN PLASTIC LAMINATE COUNTERTOPS BY PLUMBING TRADE.
ALL SINKS IN SOLID SURFACE TOPS BY SOLID SURFACE MANUFACTURER.
GENERAL PLASTIC LAMINATE CASEWORK SYMBOLS:
COUNTERTOP TYPE, SEE:
HCB HIDDEN COUNTERTOP BRACKET, SEE:
KS KNEE SPACE
FOR TYPICAL CABINET CONSTRUCTION, SEE:
ADJUST. SHELVES
SHOWN DASHED
VALANCE
BEHIND DOORS
1" SIDE OVERHANG
3/4" SIDE TOESPACE
4" BACK AND
SIDE SPLASH
RETURN VALANCE
AT FINISHED END
ONLY
SLOPED PLASTIC
LAMINATE CLOSURE
F7
A701B
D9
A701B
F2
A701B
D9
A701B
U N
L E
S S
N O
T E
D O
T H
E R
W
IS
E
FULL HEIGHT CABINET CONSTRUCTION
3/4" FIXED SHELF
AT CENTER
24" DEEP UNLESS
NOTED OTHERWISE
TOE SPACE:
3" AT FRONT
3/4" AT SIDES
ADJUSTABLE
SHELVES
TYPICAL
V A
R
IE
S
S E
E E
L E
V A
T
IO
N
U N
L E
S S
N O
T E
D O
T H
E R
W
IS
E
V A
R
IE
S
S E
E E
L E
V A
T
IO
N
BASE AND WALL CABINET CONSTRUCTION
TOE SPACE:
3" AT FRONT
3/4" AT SIDES
ADJUSTABLE SHELF
FULL SUBTOP
ADJUSTABLE
SHELF SEE
ELEVATIONS
FOR QUANTITY
UNDER CABINET
(U.C.) LIGHT BY
ELECTRICAL
TRADE
FACE OF "OPEN"
CABINET WHERE NOTED
ON ELEVATIONS
23 1/4" AT OPEN CABINETS
14 1/4" AT "OPEN"
CABINET
UNLESS NOTED
OTHERWISE
3/4" SETBACK
AT "OPEN"
UNLESS NOTED OTHERWISE
23 1/4" AT "OPEN" CABINET
3/4"
SETBACK AT
"OPEN"
14 1/4"
23 1/4"
24" DEEP UNLESS
NOTED OTHERWISE
15" DEEP UNLESS
NOTED OTHERWISE
VALANCE
A
A
SECTION A-A
FINISHED END
PANEL OF WALL
CABINET
VALANCE IN
FOREGROUND
SHOWN DASHED
GENERAL CASEWORK NOTES
UNLESS NOTED OTHERWISE:
1. CABINETS SHALL BE FABRICATED WITH 3/4" MATERIAL, EXCEPT AS
FOLLOWS:
A. SHELVES OVER 29" SHALL BE 1".
B. CABINET BACKS SHALL BE 1/2" OR 1/4" MDF DADOED INTO TOP,
BOTTOM, AND SIDES
C. DRAWER SLIDES, BACK, SUBFRONT, AND BOTTOM SHALL BE
1/2"
D. DRAWER BOTTOMS SHALL BE 1/2" OR 1/4" MDF DADOED INTO
SIDES AND BACK.
2. PROVIDE SLOPED PLASTIC LAMINATE CLOSURE ABOVE ALL
WALL/FULL HEIGHT CABINETS. FACE OF SLOPED CLOSURE SHALL
ALIGN WITH FRONT FACE OF CABINET BODY (LESS CABINET
DOORS) AND END OF CLOSURE SHALL ALIGN WITH CABINET
FINISHED END PANEL (NO OVERHANG).
3. VALANCE AT WALL CABINETS SHALL BE ACROSS FRONT OF
CABINETS AND AT FINISHED ENDS ONLY. VALANCE AT FINISHED
ENDS SHALL BE CONSTRUCTED AS PART OF FINISHED END PANEL
OF WALL CABINET. DO NOT PROVIDE VALANCE BETWEEN EACH
WALL CABINET.
4. BASE MATERIAL AT TOE SPACE SHALL BE AS LISTED IN NEW ROOM
FINISH SCHEDULE.
5. SEE COUNTERTOP PROFILES DETAILED AT:
6. ALL BASE CABINETS WITH SINKS SHALL BE FABRICATED USING
MOISTURE RESISTANT PARTICLE BOARD.
7. BASE / FULL HEIGHT CABINETS WHICH OCCUR ON EITHER SIDE OF
CABINETS CONTAINING SINKS SHALL BE FABRICATED USING
MOISTURE RESISTANT PARTICLE BOARD.
D9
A701B
V A
R
IE
S
S E
E E
L E
V A
T
IO
N
FULL
SUBTOP
HAMPER
OPEN FRONT
12" DIA. FINISHED
TOWEL DROP HOLE
WITH EASED EDGE
1'-7"
1'-6"
/2
1" CABINET DEPTH
VARIES WITH CABINET DEPTH
B
D
TYPE
CONDITIONS AT SINK
1 3/4" AT OPEN
CABINETS
SIDE SPLASH AT WALL,
COLUMN, OR CABINET
SEALANT
1/2" SOLID
SURFACE
EASED EDGE
1/8"
SEALANT
SEALANT
UNDER MOUNT SINK
BY COUNTERTOP
MANUFACTURER
DROP IN SINK
BY PLUMBING
TRADE
PLASTIC LAMINATE
TYPE SOLID SURFACE
/2
VARIES WITH CABINET DEPTH
1" CABINET DEPTH
SCRIBE STRIP
1 3/4" AT OPEN
CABINETS
SIDE SPLASH AT WALL,
COLUMN, OR CABINET
3/4" RADIUS
PLASTIC
LAMINATE
BASE CABINET
FULL SUB-TOP
SUBSTRATE AS SPECIFIED
BASE
CABINET
FULL
SUB-TOP
SUBSTRATE AS SPECIFIED
3/4" RADIUS
APPLY RUBBER
BASE OVER
CONCRETE
FORMED
METAL
LOCKERS
CONCRETE
CURB
VARIES - SEE ELEVATION
16" X 16" X 3/8" AT
18" COUNTERTOP
WOOD BLOCKING
V A
R
IE
S
S E
E E
L E
V A
T
IO
N
HIDDEN COUNTER
BRACKET (HCB)
20" X 20" X 1/2" AT
25" / 30" COUNTERTOPS
RECESS BRACKETS SO
FASTENERS ARE CONTAINED
WITHIN STUD SPACE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
UPGRADE AHU 09 & LOCKER ROOM
OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
ARCHITECT/ENGINEER
310 Pine Street | Green Bay, WI 54301 920-432-4865 | www.berners-schober.com
BID DOCUMENTS
FULLY SPRINKLERED
Comm. Number: 5700.05
OCTOBER 8, 2018
585-17-111
U.S. Department of Veterans Affairs
C U s e rs \j p o g ra n t\ D o c u m e n ts
\O G
J M
C
C E
N T
R A
L A
R C
H jp o g ra n t.
rv t
/1
/2
:5
:4
P M
Checker Author
A701B
CASEWORK DETAILS
DWG. 8 OF 28
1" = 1'-0" F6
ACCESSIBLE VANITY
1" = 1'-0"
F5
MICROWAVE SHELF
1" = 1'-0" F7
TYPICAL CABINET CONSTRUCTION - SLOPED PLAM CLOSURE
1" = 1'-0"
F4
BASE CABINET HAMPER
3" = 1'-0" D9
COUNTERTOP TYPES
1" = 1'-0" F1
LOCKER CURB
1" = 1'-0"
F2
HIDDEN COUNTER BRACKET (HCB)
Revisions: Date:
FINISH LEGEND
06 20 00 FINISH CARPENTRY
SOLID SURFACE WINDOW SILLS: SS3 - CORIAN BONE
08 14 00 INTERIOR WOOD DOORS
GRADE A, ROTARY CUT WHITE BIRCH, CUSTOM STAIN TO MATCH EXISTING
09 30 13 PORCELAIN TILING
PORCELAIN TILE:
PPT1 CROSSVILLE, 12" X 12" MAINSTREET AV213 BISTRO BROWN
CERAMIC WALL TILE:
CWT1 CERAMIC TILEWORKS, 4" X16" MOD, BISCUIT
GROUT: TEC POWER GROUT
GT1 935 SILHOUETTE - AT FLOORS AND WALLS
TRIM PIECES:
TR1 SCHLUTER, BULLNOSE OUTSIDE CORNERS, RONDEC; AE SATIN ANODIZED ALUMINUM
TR2 SCHLUTER, COVE BASE, DILEX AHK; AE SATIN ANODIZED ALUMINUM
TR3 SCHLUTER, EDGE PROTECTION, SCHIENE; AE SATIN ANODIZED ALUMINUM
09 51 00 ACOUSTICAL CEILINGS
ACT1 ARMSTRONG, CIRRUS 534, 15/16" GRID, 2' X 2' TEGULAR EDGE
ACT2 ARMSTRONG, CORTEGA 704, 15/16" GRID, 2' X 2' TEGULAR EDGE
ACT3 ARMSTRONG, ULTIMA HEALTHZONE 1935, 15/16" GRID, 2' X 2' SQUARE EDGE
ACT4 CERTAINTEED, AQUAROCK 1182-CRF-1SV, 15/16" ALUMINUM GRID, 2' X 2' SQUARE EDGE
09 65 13 RESILIENT BASE AND ACCESSORIES
RESILIENT BASE:
RB1 JOHNSONITE 80 FAWN
09 65 16 RESILIENT SHEET FLOORING
RESILIENT SHEET FLOORING:
RSF1 MANNINGTON, BIOSPEC MD 15362 ECRU
WELD ROD: MANNINGTON 842405
STAINLESS STEEL COVE CAP AT INTEGRAL BASE
09 65 19 RESILIENT TILE FLOORING
LUXURY RESILIENT TILE:
LRT1 KARNDEAN, 16" X 16" DA VINCI LST05 SANTI LIMESTONE (MONOLITHIC INSTALL)
VINYL COMPOSITION TILE:
VCT1 ARMSTRONG, STANDARD EXCELON 51811 ANTIQUE WHITE
VCT2 ARMSTRONG, STANDARD EXCELON 51876 MINT CREAM
09 91 00 PAINTING
P1 SHERWIN WILLIAMS 7526 MAISON BLANCHE
P2 SHERWIN WILLIAMS 6156 RAMIE
P3 SHERWIN WILLIAMS 7505 MANOR HOUSE
P4 NOT USED
P5 NOT USED
P7 NOT USED
P8 NOT USED
P9 NOT USED
P10 SHERWIN WILLIAMS 7527 NANTUCKET DUNE (HOLLOW METAL FRAMES)
EPOXY PAINT:
EP1 SHERWIN WILLIAMS 7006 EXTRA WHITE
EP2 SHERWIN WILLIAMS 7256 MAISON BLANCHE
EP3 NOT USED
EP4 SHERWIN WILLIAMS 7622 HOMBURG GRAY
10 21 13 TOILET PARTITIONS
METPAR, SP638 STONE GRANITE
10 21 16 SHOWER STALLS
SHOWER PAN:
SHP1 INPRO CORPORATION, BIO PRISM P9002 WHITE SAND
SHOWER WALLS:
SHW1 INPRO CORPORATION, BIO PRISM P9702 ARID
10 26 00 WALL PROTECTION
HANDRAIL:
HR1 INPRO CORPORATION, 800 SERIES, 0110 MONTEREY
CORNERGUARDS:
CG1 INPRO CORPORATION, 150 SERIES, 3" WING, 8' HIGH, 0110 MONTEREY
STAINLESS STEEL CORNERGUARDS:
SCG1 INPRO CORPORATION, 3-1/2", 430 STANDARD GRADE, CEMENT-ON 16 GAUGE, 8' HIGH
SHEET WALL PROTECTION:
SWP1 INPRO CORPORATION, PALADIUM RIGID SHEET 0.060" THICKNESS, 0110 MONTEREY
SWP2 INPRO CORPORATION, PALADIUM RIGID SHEET 0.060" THICKNESS, 0547 AMBER CHERRY
10 51 13 FORMED METAL LOCKERS
LYON; 52 CANYON
12 32 00 MANUFACTURED WOOD CASEWORK
PLASTIC LAMINATE:
PL1 FORMICA 7012-58 AMBER MAPLE
PL2 NOT USED
PL3 NOT USED
12 38 00 COUNTERTOPS
SOLID SURFACE:
SS1 CORAIN MAUI
SS2 MEGANITE 373 AR MOROCCO MIST
SS3 CORIAN BONE
GENERAL INTERIOR FINISH NOTES:
1. SEE AR101B SHEET FOR CEILING MATERIAL, TYPE, AND HEIGHT.
2. SEE A101B SHEET FOR CORNER GUARD (CG#), CHAIRRAIL (CR#), AND HANDRAIL (HR#) LOCATIONS.
3. SINGLE OR FIRST FINISH TYPE IN NEW ROOM FINISH SCHEDULE COLUMN INDICATES FIELD FINISH IN ENTIRE ROOM. ADDITIONAL FINISH TYPE(S) IN NEW ROOM
FINISH SCHEDULE COLUMN INDICATES ACCENT(S). SEE I100 SERIES SHEETS FOR ACCENT FLOOR AND WALL FINISH TYPE LOCATIONS.
4. INSTALL ALL MANUFACTURED ITEMS, MATERIALS, AND EQUIPMENT IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDED SPECIFICATIONS.
5. ALL REQUESTS FOR SUBSTITUTIONS FOR SPECIFIED ITEMS SHALL BE SUBMITTED IN WRITING; WITH ALTERNATIVE PRODUCT INFORMATION TO THE ARCHITECT
AND WILL BE CONSIDERED ONLY IF DEEMED ACCEPTABLE WITH REGARD TO QUALITY, APPEARANCE AND FUNCTION. REFER TO SPECIFICATIONS FOR PROCEDURE.
6. FOR ITEMS NOT SPECIFIED, ASSUME INTERIOR SELECTIONS WILL BE MADE FROM FULL RANGE OF MANUFACTURER'S STANDARDS INCLUDING PREMIUM COLORS.
7. IF THERE IS A CONFLICT BETWEEN DRAWINGS AND THE SCHEDULE, CONTACT THE ARCHITECT FOR CLARIFICATION.
8. SALVAGE FLOOR, BASE, WALL COVERING AND CEILING TILE FOR REUSE AS NOTED.
FLOORING:
1. ALL EXPOSED CONCRETE FLOORS SHALL BE SEALED UNLESS OTHERWISE NOTED, REFERENCE ARCHITECTURAL SPECIFICATIONS.
2. FLOAT FLOORS AS NECESSARY TO PROVIDE FLUSH TRANSITIONS BETWEEN FLOORING MATERIALS. SEE XXXXX SHEET FOR FLOOR TRANSITIONS.
3. CENTER ALL FLOORING TRANSITIONS DIRECTLY UNDER THE CENTERLINE OF DOOR IN CLOSED POSITION.
BASE:
1. BASE SHALL BE ROLL GOODS, NOT SECTIONS OR PIECE GOODS.
WALLS:
1. REFER TO THE PAINT SCHEDULE IN THE SPECIFICATIONS FOR THE SPECIFIC PAINT SYSTEM LOCATIONS.
2. WHERE ACCENT PAINTS ARE INDICATED ON THE DRAWINGS, COLOR IS TO EXTEND TO THE LENGTH AND ENDS ON THE INSIDE CORNER WHERE INDICATED.
3. ALL METAL GRILLES,…