S06 Asbestos Survey Report - Mental Health Bed Renovation project.pdf
PDF 1 MB Posted
- Attached to
- Z1DA--Increase Mental Health Beds 506-20-101
- Solicitation number
- 36C25022B0051
About this file
This asbestos survey report documents the results of an inspection conducted at the Ann Arbor VA Medical Center to identify asbestos-containing materials in areas designated for renovation. The survey identified several homogeneous sampling areas containing asbestos, including transite paneling and boards, brown fiber boards, floor tiles and mastic. No new suspect materials were found in Building 8. Analytical testing showed that samples collected from three materials in Building 28, including floor tiles, mastic and spray-on insulation, did not contain asbestos. The report provides the location and estimated quantities of previously identified asbestos-containing materials and concludes with limitations of the survey.
This pre-solicitation notice announces the Department of Veterans Affairs' intent to issue an invitation for bids for a project to renovate the acute inpatient and outpatient mental health units at the Ann Arbor VA Medical Center. The project scope includes demolition, installation and commissioning to provide a complete and usable mental health unit. The estimated cost range is $5-10 million. The contract type will be firm fixed price with award planned within 120 days of bid opening. The solicitation is designated as 100% set-aside for verified service-disabled veteran-owned small businesses. The solicitation will be issued on or around May 30, 2022 and available through SAM.gov. Questions should be directed to the specified contracting officer by email only.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RDC/John Poe Architects Dayton, Ohio
NESHAP Asbestos Survey Mental Health Bed Renovation Ann Arbor VA Medical Center
Ann Arbor, MI
January 2020
1915 North 12th Street Toledo, OH 43604-5305
T 419-324-2222 F 419-241-1808 www.ttlassoc.com
January 28, 2020 TTL Project No. 1860101
Pamela Rigling RDC/John Poe Architects 116 East Third Street Dayton, Ohio 45202
NESHAP Asbestos Survey
Ann Arbor VA Medical Center
Ann Arbor, MI Dear Ms. Rigling, The report for the NESHAP Asbestos Survey conducted for RDC/John Poe Architects (RDC) for the above-referenced site is enclosed.
TTL appreciates the opportunity to provide RDC with our consulting and testing services. Should you have any questions or require additional information, please contact Mr. Harjot Singh at (419) 214-5058.
Sincerely, TTL Associates, Inc.
Harjot Singh Project Manager
Veronica Winkeljohn, P.E., PMP Federal Services Director
R:\SUB\RDC-John Poe Architects\VA - Proj 506-20-101 - Medical Beds - Ann Arbor -2019 (1860101)\Report\Asbestos Survey Report.docx
NESHAP ASBESTOS SURVEY
MENTAL HEALTH BED RENOVATION
ANN ARBOR VA MEDICAL CENTER
ANN ARBOR, MI
FOR
RDC/JOHN POE ARCHITECTS
116 EAST THIRD STREET
DAYTON, OHIO 45202
SUBMITTED
JANUARY 28, 2020
TTL PROJECT NO. 1860101
TTL ASSOCIATES, INC.
1915 NORTH 12TH STREET
TOLEDO, OHIO 43604
(419) 324-2222
Ann Arbor VA Medical Center January 2020 TTL Project No. 1860101 Page i
TABLE OF CONTENTS
Section No. Page No.
EXECUTIVE SUMMARY ...................................................................................................... E-1
1.0 INTRODUCTION
1.1 Project Purpose and Objectives
1.2 Personnel
2.0 ASBESTOS SURVEY
2.1 Homogenous Areas
2.2 Sampling and Analysis Methods
2.3 Survey Analytical Results
3.0 CONCLUSIONS AND RECOMMENDATIONS
3.1 Asbestos Survey
3.2 Limitations
APPENDICES
Appendix A: Certifications Appendix B: Asbestos Survey Summary Table Appendix C: Asbestos Analytical Report Appendix D: Asbestos Sampling Location Map Appendix E: Previous Survey Results
TTL Project No. 1860101 Page E-1
EXECUTIVE SUMMARY
TTL Associates, Inc. (TTL) conducted a NESHAP Asbestos survey to assess the existing materials in selected areas of the 8th floor in Building 1 and 1st floor of Building 28 in the Ann Arbor VA Medical Center located in Ann Arbor, Michigan. The purpose of the survey was to identify asbestos-containing materials (ACM) in renovation areas of the Ann Arbor VA Medical Center identified by RDC. The survey was conducted on January 14, 2020, by Mr. Harjot Singh of TTL.
TTL’s scope of work included the following:
• Surveying the renovation area for suspect ACM.
• Collection of suspect ACM bulk samples for analysis by Polarized Light Microscopy (PLM) to determine asbestos content.
Asbestos Survey
TTL used the previous ACM data report provided by RDC and the Ann Arbor VAMC to assess if previously identified ACM was present in the renovation areas. Any suspect materials that were not identified and sampled in the previous data report were identified, quantified and samples were collected.
A total of 11 samples were collected and 13 sample layers were analyzed from three suspect materials from Building 28. None of the sampled materials were found to be asbestos-containing based upon laboratory analysis. No new suspect materials were identified in Building 8.
TTL Project No. 1860101 Page 1
1.0 INTRODUCTION
TTL Associates, Inc. (TTL) conducted a NESHAP Asbestos Survey to assess the existing materials in selected areas of the 8th floor in Building 1 and 1st floor of Building 28 on January 14, 2020 in the Ann Arbor VA Medical Center located in Ann Arbor, Michigan.
1.1 Project Purpose and Objectives
TTL conducted the survey in the areas designated for renovation on the 8th floor in Building 1 and on the 1st floor in Building 28 to determine the presence of asbestos-containing materials (ACM) which may require removal prior to renovation activities.
1.2 Personnel
The non-destructive asbestos survey was conducted by Mr. Harjot Singh. Mr. Singh is certified by the State of Michigan Department of Licensing and Regulatory Affairs (LARA) as an asbestos inspector. A copy of his certification is located in Appendix A.
TTL Project No. 1860101 Page 2
2.0 ASBESTOS SURVEY
This section documents the methodology and results of the asbestos survey.
2.1 Homogenous Areas
Each accessible area within the renovation area of the Ann Arbor VA Medical Center was surveyed, which included the identification of suspect materials and the definition of homogeneous sampling areas (HSA), assessment of the condition of each material, estimation of the approximate quantity of the suspect ACM, and collection and analysis of representative bulk samples from each identified HSA. An HSA is defined as a material that exhibits similar physical characteristics (e.g., texture, surface color, and appearance) and was applied or installed during the same construction period (if known) as determined by TTL’s inspector utilizing professional judgment, experience, and historical building information.
2.2 Sampling and Analysis Methods
TTL provided a State of Michigan Department of Licensing and Regulatory Affairs (LARA) asbestos inspector to conduct an inspection of the renovation area.
The samples were collected using a coring device or other means, as appropriate, to collect a cross-section of the suspect material. The samples were placed into clean and unused sealable bags marked with a unique sample identification number. The samples of suspect ACM were analyzed by polarized light microscopy (PLM) using U.S. EPA Method 600/R-93/116 by an independent asbestos laboratory. The laboratory is accredited by the National Voluntary Laboratory Accreditation Program (NVLAP) which is administered by the National Institute of Standards and Technology (NIST).
2.3 Survey Analytical Results
A total of 11 samples were collected and 13 sample layers were analyzed from three suspect materials from Building 28. None of the sampled materials were found to be asbestos-containing based upon laboratory analysis. No new suspect materials were identified in Building 8.
Refer to the Asbestos Survey Summary Table in Appendix B for a listing of the materials identified and the analytical results. The laboratory analytical report is located in Appendix C. The sampling location map is included in Appendix D.
TTL Project No. 1860101 Page 3
3.0 CONCLUSIONS AND RECOMMENDATIONS
This section summarizes the results of the asbestos survey and provides conclusions and recommendations.
3.1 Asbestos Survey
The U.S. EPA defines regulated asbestos-containing material (RACM) as: (a) Friable asbestos material, (b) Category I non-friable ACM that has become friable, (c) Category I non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading, or (d) Category II non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of demolition or renovation operations. The following materials were identified or assumed as ACM as defined by the U.S. EPA:
• Approximately 144 square feet (s.f.) of Transite panel/board material (HSA 237)*
• Approximately 144 s.f. of Brown fibrous board material (HSA 238)*
• Approximately 4 s.f. White sink undercoating (HSA 242)*
• Approximately 37 s.f. of 1’x1’ Olive with brown and white flecks floor tile(HSA 181)*
• Approximately 37 s.f. of Mastic associated with HSA #182 (HSA 182)*
• Approximately 129 s.f. of 1’x1’ Olive with green and white streaks floor tile(HSA 184)*
• Approximately 129 s.f. of Mastic associated with HSA #184 (HSA 185)*
*materials identified to be ACM during previous survey.
3.2 Limitations
TTL has made reasonable efforts to identify and quantify suspect ACM based upon the standard of care in the environmental industry existing at the time of the survey. This survey only summarizes the potential presence and estimated quantities of visually observed ACM within the designated areas.
Additional material disturbed during renovation or demolition activities should be evaluated on a case-by-case basis, especially materials that were previously hidden, obscured or inaccessible, to determine if the material is included in this survey. If a given material is not described in this survey or cannot be identified as a non-suspect material, the material should be assumed to contain asbestos and renovation and/or demolition activities should be halted until sampling and analysis can be accomplished. Parties conducting renovation and/or demolition activities should follow all applicable federal, state, and local regulations in handling identified and suspect ACM.
The information contained in the report was based upon specific parameters and regulations in force at the time of the survey. The information herein is only for the specific use of RDC and TTL, unless written authorization is obtained from TTL. TTL accepts no responsibility for the use, interpretation, or reliance by other parties on the information contained herein, nor does this report represent an instrument of regulatory compliance or an asbestos abatement specification.
Veronica Winkeljohn Did we verify these materials still exist and the quantities are correct?
Harry Singh Yes, these were checked and quantities verified.
APPENDIX A
CERTIFICATIONS
APPENDIX B
ASBESTOS SURVEY SUMMARY TABLE
Homogeneous Sampling Areas Table
Ann Arbor VA Medical Center
Ann Arbor, MI
HSA # Material Description Friability Functional Area Quantity Units Sample Number Sample Results 237 Transite panel/board material NF-II Building 1 - A851 24 SF Positive** 237 Transite panel/board material NF-II Building 1 -A851c 24 SF Positive** 237 Transite panel/board material NF-II Building 1 -A851j 48 SF Positive** 237 Transite panel/board material NF-II Building 1 -A851I 24 SF Positive** 237 Transite panel/board material NF-II Building 1 -A854 24 SF Positive**
Total 144 SF
238 Brown fibrous board material NF-II Building 1 - A851 24 SF Positive** 238 Brown fibrous board material NF-II Building 1 -A851c 24 SF Positive** 238 Brown fibrous board material NF-II Building 1 -A851j 48 SF Positive** 238 Brown fibrous board material NF-II Building 1 -A851I 24 SF Positive** 238 Brown fibrous board material NF-II Building 1 -A854 24 SF Positive**
Total 144 SF
242 White sink undercoating NF-II Building 1 - A851a 4 SF Positive**
Total 4 SF
181 1'x1' Olive with brown and white flecks floor tile NF-I Building 1 - A853 37 SF Positive**
Total 37 SF
182 Mastic under HA #181 NF-I Building 1 - A853 37 SF Positive**
Total 37 SF
184 1'x1' Olive with green and white streaks floor tile NF-I Building 1 - A854 129 SF Positive**
Total 129 SF
185 Mastic under HA #184 NF-I Building 1 - A854 129 SF Positive**
Total 129 SF
1 12" x 12" Brwon pattern floor tile and glue NF-I Building 28 - Men's Locker Room 300 SF 1A, 1B Negative
Total 300 SF
2 Residual Glue/Mastic NF-I Building 28 - F100 & F116 1,600 SF 2A, 2B Negative 2 Residual Glue/Mastic NF-I Building 28 - F106 100 SF Negative 2 Residual Glue/Mastic NF-I Building 28 - F105 100 SF Negative 2 Residual Glue/Mastic NF-I Building 28 - F104 80 SF Negative
Total 1,880 SF
3 Spray-On Insulation F Building 28 - 1st Floor Throughout 3A, 3B, 3C, 3D, 3E, 3F, 3G Negative
Total Throughout
** Samples identified as positive per previous survey
SF=Square Foot LF=Linear Foot
TTL Project No. 1860101 1 of 1
APPENDIX C
ASBESTOS ANALYTICAL REPORT
APPENDIX D
ASBESTOS SAMPLING LOCATION MAP
APPENDIX E
PREVIOUS SURVEY RESULTS
VA Medical Center - Ann Arbor, MI - HA List
HA MATL HA DESCRIPTION COMMENT
1 MM 1' x 1' Floor tile; Cream with brown streaks (light and dark) Positive
2 MM 7" Black vinyl cove base Negative
3 MM Mastic under HA # 1 Positive
4 MM Mastic under HA # 2 Negative
5 MM 2' x 2' Ceiling tile; White with random pattern & smooth finish Negative
6 TSI Mudded pipe fittings on steam lines; <2" diameter pipes Positive
7 MM 1' x 1' Floor tile; Tan with brown and white streaks Positive
8 MM Mastic under HA # 7 Negative
9 TSI Insulation on domestic pipe straight runs; <2" diameter pipes Positive
10 SM Plaster on expanded wire mesh ceiling Negative
11 MM 6" Brown vinyl cove base Negative
12 MM Mastic under HA # 11 Negative
13 MM 9" x 9" Floor tile; Olive with brown and white streaks Positive
14 MM 4" Black vinyl cove base Negative
15 MM Mastic under HA # 14 Negative
16 MM Mastic under HA # 13 Positive
17 TSI Insulation on straight run; <2" dia. Pipes Negative
18 TSI Mudded pipe fittings on domestic water lines; <2" dia. Pipes Positive
19 MM 1' x 1' Ceiling tile; Random pattern, smooth finish; glued on Negative
20 MM 1' x 1' Floor tile; White with grey flecks Positive - Only Bldg. 22
21 MM 7" Brown vinyl cove base Negative
22 MM Mastic under HA # 21 Negative
23 MM Mastic under HA # 20 Positive - Only Bldg. 22
24 MM
2' x 2' Ceiling tile; White with random dotted pattern, smooth finish Negative
25 TSI Insulation on steam pipes; >2", <6" diameter pipes Positive
26 TSI Mudded pipe fittings on steam lines; >2", <6" diameter pipes Positive
27 MM Linoleum, Brown terrazzo pattern Positive - No Longer
Found in Facility
28 MM Mastic under HA # 27 Negative
29 MM 4" Tan vinyl cove base Negative
30 MM Mastic under HA # 29 Negative
31 MM 7" Grey vinyl cove base Negative
32 MM Mastic under HA # 31 Negative
33 MM 2' x 2' Ceiling tile; White with rough finish; lay-in Negative
34 MM 1' x 1' Floor tile; Tan with blue, brown and white flecks Negative
35 MM Mastic under HA # 34 Negative
Page: 1 of 111
June, 2019
36 MM 6" Tan vinyl cove base Negative
37 MM Mastic under HA # 36 Negative
38 MM 7" Blue vinyl cove base Negative
39 MM Mastic under HA # 38 Negative
40 TSI CWS fittings >2" - <6" diameter Positive - No Longer
Found in Facility
41 TSI HWS fittings <2" diameter Negative
42 TSI HWR fittings <2" diameter Positive - No Longer
Found in Facility
43 TSI Drip return fittings <2" diameter Positive - No Longer
Found in Facility
44 TSI LPS straight runs on pipes <2" diameter Positive
45 TSI LPS fittings <2" diameter Positive - No Longer
Found in Facility
46 TSI LPS fittings, >2" - <6" diameter Positive - No Longer
Found in Facility
47 TSI MPS fittings <2" diameter Positive - No Longer
Found in Facility
48 TSI MPS vessel mud insulation Negative
49 TSI HWR vessel mud insulation Negative
50 TSI Condensate fittings <2" diameter Positive - No Longer
Found in Facility
51 TSI Make-up water fittings <2" diameter Positive - No Longer
Found in Facility
52 TSI CWS vessel mud insulation Negative
53 TSI Make-up water straight runs <2" diameter Positive - No Longer
Found in Facility
54 MM Blue check wall covering Negative
55 MM Tan cloth-pattern wall covering Negative
56 SM White finish plaster Negative
57 MM Linoleum, Dark brown terrazzo pattern Positive - No Longer
Found in Facility
58 MM Drywall with mud and tape Negative
59 MM Light blue wall covering Negative
60 MM
Vibration Decoupler on HVAC duct (Exp. joint grey woven material)
Positive - No Longer
Found in Facility
61 MM Tan cloth wall cover with wheat head graphics Negative
62 MM Beige cloth wall covering with horizontal grain Negative
63 MM 2' x 4' Ceiling tile; White with eight raised panels Negative
64 MM 1' x 1' Floor tile; Tan with white and grey specks Negative
65 MM 2' x 2' Wall panels with regular-spaced holes Positive
66 MM 1' x 2' Ceiling tile; White fibrous (old, above ceiling in sacristy) Negative
67 MM 4" Burgundy vinyl cove base Negative
68 MM Mastic under HA # 67 Negative
Page: 2 of 111
69 TSI Mudded pipe fittings on millboard-insulated lines <2" diameter Positive
70 TSI Straight run millboard insulation <2" diameter pipes Positive
71 TSI Mag insulation on <2" diameter pipes Positive
72 MM Mauve burlap-pattern wall covering Negative
73 MM Tan with blue specks wallpaper Negative
74 TSI Air cell pipe insulation straight runs <2" diameter Positive - No Longer
Found in Facility
75 TSI Black cork pipe insulation with tan seams Negative
76 MM 2' x 4' Ceiling tile, White lay-in with random dotted pattern Negative
77 MM 9" x 9" Floor tile; Beige with white streaks Negative
78 MM Mastic under HA # 77 Positive - No Longer
Found in Facility
79 MM 1' x 1' Floor tile; Cream with caramel swirl pattern Negative
80 MM Mastic under HA # 79 Positive - No Longer
Found in Facility
81 MM 1' x 1' Floor tile; Cream with caramel streaks pattern Negative
82 MM Mastic under HA # 81 Positive
83 MM 1' x 1' Floor tile; Aqua with red, black and white dots Negative
84 MM Mastic under HA # 83 Positive - No Longer
Found in Facility
85 MM 1' x 1' Floor Tile; Beige with blue and red Negative
86 MM Mastic under HA # 85 Positive
87 MM Zigzag pattern wall cover; tan, blue and white Negative
88 MM Linoleum, Grey terrazzo pattern Negative
89 MM Mastic under HA # 88 Negative
90 MM Cream vinyl cloth-pattern wall cover Negative
91 MM Criss-cross pattern mauve-colored wall covering Negative
92 MM Dark blue cloth pattern wall covering Negative
93 MM 2' x 2' Ceiling panel; Drywall with vinyl finish Negative
94 MM Mauve vertical-textured stripe wall covering Negative
95 MM 4" Cream vinyl cove base Negative
96 MM Mastic under HA # 95 Negative
97 MM Blue with white specks wall covering Negative
98 MM Pink with tiny (1/8") squares wall covering Negative
99 MM 2 1/2' x 5' Ceiling tile; White with pin holes Negative
100 TSI Mag-insulated pipes and fittings >2" - <6" diameter Positive
101 MM 9" x 9" Floor Tile; Darker Negative
102 MM Blue herringbone pattern wall cover Negative
103 MM Mastic under HA # 101 Negative
104 MM Beige wall covering with mild white texture Negative
105 MM Cream wall covering with repeating 6-groove pattern Negative
106 MM Pale yellow wall covering with mustard swirls Negative
107 MM 1' x 1' Floor tile; Tan with brown and grey flecks Negative
Page: 3 of 111
108 MM Mastic under HA # 107 Positive - No Longer
Found in Facility
109 MM Blue vertical-texture stripe wall covering Negative
110 SM White rolled-on ceiling texture Negative
111 MM Beige ladder-pattern wall covering Negative
112 MM 1' x 1' Ceiling tile; White painted worm-hole Negative
113 MM Orange-peel texture wall covering - assorted pastel colors Negative
114 MM Dark colors orange-peel-texture wall covering Negative
115 MM Blue ladder-pattern wall covering Negative
116 TSI Felt insulation on domestic straights >2 - <6" Negative
117 TSI Mudded pipe fittings on felt-insulation lines >2 - <6" Positive - No Longer
Found in Facility
118 MM Mauve cloth-pattern wall covering Negative
119 MM 9' x 9' Floor tile; Red with cream streaks Positive
120 MM Mastic under HA # 119 Positive
121 MM Blue vinyl with mild texture wall covering Negative
122 TSI HPS Mudded fittings <2" Positive - No Longer
Found in Facility
123 TSI Chilled water mudded fittings < 2" Positive - No Longer
Found in Facility
124 MM White vinyl wall covering Negative
125 MM 1' x 1" Floor tile; Beige with white streaks Negative
126 MM Mastic under HA # 125 Negative
127 MM Cork ceiling 3" deep Negative
128 MM Linoleum, White with blue, brown and tan specks Negative
129 MM Mastic under HA # 128 Negative
130 SM Spray-on insulation Positive - 8th Floor Only
131 MM Linoleum, Blue with grey and dark specks Negative
132 MM Mastic under HA # 131 Negative
133 MM 2' x 4' Ceiling tile; Large pattern white Negative
134 TSI Drain fittings >2" - <6" Positive
135 MM Linoleum, tan with grey and dark specks Negative
136 MM Mastic under HA # 135 Negative
137 MM Fibrous drywall Negative
138 MM Plaster fill material around conduit penetrations through Floor Negative
139 TSI Drain line >2" - <6" Positive
140 MM
Off-white with 1/4" squares random peach and grey dots wall cover Negative
141 MM Peach border wall covering Negative
142 MM Pale yellow cloth-like wall covering Negative
143 MM Green ladder-pattern wall covering Negative
144 TSI New mud on newly-insulated fiberglass lines Negative
145 TSI Cork on brine line <2" Negative
Page: 4 of 111
146 MM Tan herringbone (3" wide pattern) wall covering Negative
147 MM 1' x 1' Floor tile; Light grey with blue, aqua and dark grey dots Negative
148 MM Mastic under HA # 147 Negative
149 MM 9" x 9" Floor tile; Tan with green speckles Positive - No Longer
Found in Facility
150 MM Mastic under HA # 149 Negative
151 MM 9" x 9" Floor tile; white with grey streaks Positive - No Longer
Found in Facility
152 MM Mastic under HA # 151 Positive - No Longer
Found in Facility
153 TSI Debris left from previous activities Positive
154 MM 9" x 9" Floor tile; Black with green dots Floor tile Negative
155 MM Mastic under HA # 154 Negative
156 MM Linoleum, Beige terrazzo pattern Negative
157 MM Mastic under HA # 156 Negative
158 MM 1' x 1' Floor tile; Pink with brown, maroon and white specks Negative
159 MM Mastic under HA # 158 Negative
160 MM 1' x 1' Floor Tile with white specks Negative
161 MM Mastic under HA # 160 Negative
162 TSI Brine fittings >2" - <6" Negative
163 TSI CWS >2" - <6" Negative
164 TSI CWS fittings >2" - <6" Negative
165 TSI Steam fittings >6" Negative
166 TSI Steam pipe >6" Negative
167 TSI Cold water fitting with black tar >6" Negative
168 MM Construction adhesive lt. brown color Negative
169 MM Gasket material from wall heaters in kitchen Negative
170 MM Unknown base tiles under cafe eating area Floor Negative
171 TSI Insulation on domestic water tank Negative
172 TSI Insulation on steam tank Negative
173 MM Beige with brown and aqua diamonds wall covering Negative
174 MM
Beige with repeating pattern of lines and crosses - brown and aqua Negative
175 MM Beige with aqua lines wall covering Negative
176 MM Tan vertical-textured stripe wall covering Negative
177 TSI Chrysotile duct and insulation Positive
178 MM Mauve and aqua spattered pattern wall covering Negative
179 MM 1' x 1' Floor tile; White with grey and brown flecks Negative
180 MM Mastic under HA # 179 Negative
181 MM 1' x 1' Floor tile; Olive with brown and white flecks Positive
182 MM Mastic under HA # 181 Positive
183 MM Green with white flecks (textured) wall covering Negative
184 MM 1' x 1' Floor tile; Olive with green and white streaks Positive
Page: 5 of 111
185 MM Mastic under HA # 184 Positive
186 MM Off white with 1/4" squares and random mauve and purple dots Negative
187 MM 9" x 9" Floor tile; Olive with green and white streaks Negative
188 MM Mastic under HA # 187 Negative
189 TSI Vacuum mud fitting <2" Positive - No Longer
Found in Facility
190 MM 9" x 9" Floor tile; Blue-green with cream and navy streaks Positive - No Longer
Found in Facility
191 MM Mastic under HA # 190 Negative
192 MM Light brown with diamonds & squares (textured) wall covering Negative
193 TSI Drain pipe insulation >2" - <6" Negative
194 TSI Tar wrap on <2" domestic Negative
195 TSI Brown foam on >2" - <6" Negative
196 MM Brown fibrous pressboard Negative
197 MM Tan weave-pattern wall covering Negative
198 TSI Mud patch on fiberglass duct insulation Negative
199 TSI HW mud fitting <2" Negative
200 TSI CW Mud fitting <2" Negative
201 TSI Chilled or heating water supply Mudded pipe fittings <2" Negative
202 TSI Chilled or heating water return <2" Negative
203 TSI Chilled water return mud fitting >2" - <6" Negative
204 TSI CW straight <2" Positive - No Longer
Found in Facility
205 TSI CW straight >2" - <6" Positive - No Longer
Found in Facility
206 TSI HW straight <2" Positive - No Longer
Found in Facility
207 TSI HW straight >2" - <6" Negative
208 SM Fibrous sprayed-on in Bldg. 28 Negative
209 SM Cellulose sprayed-on in C200, Bldg. 28 Negative
210 MM 1' x 1' Floor tile; Cream with grey and brown streaks Negative
211 MM Mastic under HA # 210 Negative
212 MM 1' x 1' Floor tile; Grey with white and brown streaks Negative
213 MM Mastic under HA # 212 Negative
214 TSI Drip return fitting >2" - <6" Positive - No Longer
Found in Facility
215 MM 1" wide fibrous duct tape Positive
216 MM Linoleum, White with blue, red, purple and green specks Negative
217 MM Mastic under HA # 216 Negative
218 MM Linoleum, White with tan streaks Negative
219 MM Mastic under HA # 218 Negative
220 MM Linoleum, White with 5" grey-outline squares Negative
221 MM Mastic under HA # 220 Negative
222 MM 1' x 1' Floor tile; Green with cream and dark green steaks Negative
223 MM Mastic under HA # 222 Negative
Page: 6 of 111
224 MM Linoleum, Beige with brown streaks Positive
225 MM Mastic under HA # 224 Negative
226 MM 1' x 1' Floor tile; Light grey with aqua and dark grey streaks Positive - No Longer
Found in Facility
227 MM Mastic under HA # 226 Negative
228 TSI Roof drain straight insulation. >2", ≤6" black tar-like appearance Negative
232 TSI Steam mud fitting >2", ≤6", Bldg. 22 (Originally listed as 228a) Negative
229 TSI Domestic mud fitting ≤2", Bldg. 22 Negative
230 TSI Condensate tank mud, Bldg. 22 Negative
231 MM Mastic under HA # 64 (Originally listed as 64a) Positive
233 MM 9" x 9" Floor tile; Green with white streaks Positive - No Longer
Found in Facility
234 MM Mastic under HA # 233 Negative
235 MM 9" x 9" Floor tile; Red with cream and black streaks Positive - No Longer
Found in Facility
236 MM Mastic under HA # 235 Negative
237 MM Transite panel/board material Positive
238 MM Brown fibrous board material
Positive - Located behind transite panel on flush mounted wall registers
239 MM Black Lab Tops with groove under lip Positive
240 MM Debris from previous renovation Negative
241 MM Black sink undercoating Positive
242 MM White sink undercoating Positive
243 MM Grey sink undercoating Negative
244 MM 9" x 9" Floor tile; Light green with dark green streaks Positive - No Longer
Found in Facility
245 MM Mastic under HA # 244 Negative
246 MM Pink sink undercoating Positive
247 MM Linoleum, Tan with grey and black streaks Negative
248 MM Mastic under HA # 247 Negative
249 MM 1' x 1' Floor tile; Reddish brown with black and red streaks Negative
250 MM Mastic under HA # 249 Negative
251 MM 1' x 1" Floor tile; Grey with dark and light grey streaks Negative
252 MM Mastic under HA # 251 Negative
253 MM Black Tar sink undercoating Negative
254 MM Elevator brake pads Positive
255 SM Fire Brick Positive
276 SM Wall plaster Positive - Bldg. 3 Only
283 MM Glue pods on 1' x 1' ceiling tile Positive
285 TSI Straight run millboard insulation 2" - 6" diameter pipes Positive
286 TSI
Mudded pipe fittings on millboard - insulated lines 2" - 6" diameter pipes Positive
Page: 7 of 111
290 TSI Debris underneath Mudded Fittings Negative
291 MM Caulk, Brittle Tan Negative
292 MM Expansion Cloth, Woven Tight Weave Negative
293 MM Gasket, Felt Material Negative
294 SM Board, Gray Powdery Negative
295 MM Tar Tape Wrap on Pipe Negative
296 MM Duct Putty: Silver Negative
297 MM Duct Putty: Light Brown Positive - Bldg. 22
Penthouse
298 MM Spray-on insulation: Stairwell Positive - Bldg. 22
Penthouse
299 MM Expansion Cloth, Woven Heavy Weave Positive - No Longer
Found in Facility
300 MM Expansion Joint, Black Rubberized Negative
301 MM Expansion Joint, Silver Rubberized Negative
302 TSI Duct Insulation, Canvas & Mud over Fiberglass Negative
303 TSI CW Mud Fitting on Fiberglass Straight <2" Negative
304 TSI Abandoned Line Mud Fitting on Fiberglass Straight <2" Negative
305 TSI Steam Line, Straight Run Preformed Block >2"<4" Positive - No Longer
Found in Facility
306 TSI
Steam Line Mud Fittings on Straight Run Preformed Block
>2"<4"
Positive - No Longer
Found in Facility
307 TSI Steam Mud Fitting on Fiberglass Straight <2" Negative
308 TSI Condensate Mud Fitting on Fiberglass Straight <2" Negative
309 TSI Condensate Tank Insulation: Mud over Fiberglass Negative
310 TSI Heat Exchanger Insulation: Mud over Fiberglass Negative
311 TSI Hot Water Tank Insulation: Mud over Fiberglass Positive - No Longer
Found in Facility
312 TSI Hot Water Lines Mud Fitting on Fiberglass Straight <2" Negative
Page: 8 of 111
VA Medical Center - Ann Arbor, MI - Positive (Hot) HA List
HA MATL HA DESCRIPTION COMMENT Quantity Unit
1 MM
1' x 1' Floor tile; Cream with brown streaks
(light and dark)
10,478 SF
3 MM Mastic under HA # 1 11,451 SF
6 TSI
Mudded pipe fittings on steam lines; <2" diameter pipes
159 FTG
7 MM
1' x 1' Floor tile; Tan with brown and white streaks
706 SF
9 TSI
Insulation on domestic pipe straight runs; <2" diameter pipes
44 LF
13 MM
9" x 9" Floor tile; Olive with brown and white streaks
590 SF
16 MM Mastic under HA # 13 590 SF
18 TSI
Mudded pipe fittings on domestic water lines;
<2" dia. Pipes
148 FTG
20 MM 1' x 1' Floor tile; White with grey flecks 4,713 SF
23 MM Mastic under HA # 20 4,713 SF
TSI
Insulation on steam pipes; >2", <6" diameter pipes No Longer Found in Facility
26 TSI
Mudded pipe fittings on steam lines; >2", <6" diameter pipes
23 FTG
27 MM Linoleum, Brown terrazzo pattern No Longer Found in Facility
40 TSI CWS fittings >2" - <6" diameter No Longer Found in Facility
42 TSI HWR fittings <2" diameter No Longer Found in Facility
43 TSI Drip return fittings <2" diameter No Longer Found in Facility
44 TSI LPS straight runs on pipes <2" diameter 35 LF
45 TSI LPS fittings <2" diameter No Longer Found in Facility
46 TSI LPS fittings, >2" - <6" diameter No Longer Found in Facility
47 TSI MPS fittings <2" diameter No Longer Found in Facility
50 TSI Condensate fittings <2" diameter No Longer Found in Facility
51 TSI Make-up water fittings <2" diameter No Longer Found in Facility
53 TSI Make-up water straight runs <2" diameter No Longer Found in Facility
57 MM Linoleum, Dark brown terrazzo pattern No Longer Found in Facility
60 MM
Vibration Decoupler on HVAC duct (Exp.
joint grey woven material) No Longer Found in Facility
65 MM 2' x 2' Wall panels with regular-spaced holes 480 SF
Page: 9 of 111
69 TSI
Mudded pipe fittings on millboard-insulated lines <2" diameter
111 FTG
70 TSI
Straight run millboard insulation <2" diameter pipes
863 LF
71 TSI Mag insulation on <2" diameter pipes 508 LF
74 TSI
Air cell pipe insulation straight runs <2" diameter No Longer Found in Facility
78 MM
Mastic under HA # 77 - 9" x 9" Floor tile;
Beige with white streaks No Longer Found in Facility
80 MM
Mastic under HA # 79 - 1' x 1' Floor tile;
Cream with caramel swirl pattern No Longer Found in Facility
82 MM
Mastic under HA # 81 - 1' x 1' Floor tile;
Cream with caramel streaks pattern No Longer Found in Facility
84 MM
Mastic under HA # 83 - 1' x 1' Floor tile; Aqua with red, black and white dots No Longer Found in Facility
86 MM
Mastic under HA # 85 - 1' x 1' Floor Tile;
Beige with blue and red No Longer Found in Facility
100 TSI
Mag-insulated pipes and fittings >2" - <6" diameter
30 LF
108 MM
Mastic under HA # 107 - 1' x 1' Floor tile; Tan with brown and grey flecks No Longer Found in Facility
117 TSI
Mudded pipe fittings on felt-insulation lines >2
- <6" No Longer Found in Facility
119 MM 9' x 9' Floor tile; Red with cream streaks 9 SF
120 MM Mastic under HA # 119 9 SF
122 TSI HPS Mudded fittings <2" No Longer Found in Facility
123 TSI Chilled water mudded fittings < 2" No Longer Found in Facility
130 SM Spray-on insulation 8th Floor Only 135 SF
134 TSI Drain fittings >2" - <6" 11 FTG
139 TSI Drain line >2" - <6" 5 LF
149 MM 9" x 9" Floor tile; Tan with green speckles No Longer Found in Facility
151 MM 9" x 9" Floor tile; White with grey streaks No Longer Found in Facility
152 MM Mastic under HA # 151 No Longer Found in Facility
153 TSI Debris left from previous activities 2 LF
177 TSI Chrysotile duct and insulation 56 SF
181 MM
1' x 1' Floor tile; Olive with brown and white flecks
328 SF
182 MM Mastic under HA # 181 328 SF
184 MM
1' x 1' Floor tile; Olive with green and white streaks
770 SF
185 MM Mastic under HA # 184 770 SF
Page: 10 of 111
189 TSI Vacuum mud fitting <2" No Longer Found in Facility
190 MM
9" x 9" Floor tile; Blue-green with cream and navy streaks No Longer Found in Facility
204 TSI CW straight <2" No Longer Found in Facility
205 TSI CW straight >2" - <6" No Longer Found in Facility
206 TSI HW straight <2" No Longer Found in Facility
214 TSI Drip return fitting >2" - <6" No Longer Found in Facility
215 MM 1" wide fibrous duct tape No Longer Found in Facility
224 MM Linoleum, Beige with brown streaks 397 SF
226 MM
1' x 1' Floor tile; Light grey with aqua and dark grey streaks No Longer Found in Facility
231 MM
Mastic under HA # 64 (Originally listed as HA
# 64a)1' x 1' Floor tile; Tan with white and grey specks
No Longer Found in Facility
233 MM 9" x 9" Floor tile; Green with white streaks No Longer Found in Facility
235 MM
9" x 9" Floor tile; Red with cream and black streaks No Longer Found in Facility
237 MM Transite panel/board material 502 SF
238 MM Brown fibrous board material
Located behind transite panel on flush mounted wall registers
462 SF
239 MM Black Lab Tops with groove under lip 50 SF
241 MM Black sink undercoating 8 SF
242 MM White sink undercoating 4 SF
244 MM
9" x 9" Floor tile; Light green with dark green streaks No Longer Found in Facility
246 MM Pink sink undercoating 8 SF
254 MM Elevator brake pads 12 EA
255 SM Fire Brick No Longer Found in Facility
276 SM Wall plaster Bldg. 3 Only 1,588 SF
283 MM Glue pods on 1' x 1' ceiling tile 841 SF
285 TSI
Straight run millboard insulation 2" - 6" diameter pipes
385 LF
286 TSI
Mudded pipe fittings on millboard - insulated lines 2" - 6" diameter pipes
50 FTG
297 MM Duct Putty: Light Brown Bldg. 22 Penthouse 33 LF
298 SM Spray-on insulation: Stairwell Bldg. 22 Penthouse 20 SF
299 MM Expansion Cloth, Woven Heavy Weave No Longer Found in Facility
Page: 11 of 111
305 TSI
Steam Line, Straight Run Preformed Block
>2"<4" No Longer Found in Facility
306 TSI
Steam Line Mud Fittings on Straight Run
Preformed Block >2"<4" No Longer Found in Facility
311 TSI
Hot Water Tank Insulation: Mud over
Fiberglass No Longer Found in Facility
TOTAL ACM QUANTITIES: 42,425
TSI Straight Run Insulation TOTAL ACM QUANTITIES: 2,020 LF
TSI Mudded Pipe Fittings TOTAL ACM QUANTITIES: 502 FTG
TSI Duct TOTAL ACM QUANTITIES: 56 SF
SM Sprayed-on TOTAL ACM QUANTITIES: 155 SF
SM Plaster TOTAL ACM QUANTITIES: 1,588 SF
MM Floor Tile TOTAL ACM QUANTITIES: 17,594 SF
MM Linoleum TOTAL ACM QUANTITIES: 397 SF
MM Floor Tile Mastic TOTAL ACM QUANTITIES: 17,861 SF
MM Sink Undercoating TOTAL ACM QUANTITIES: 20 SF
MM Transite Board TOTAL ACM QUANTITIES: 982 SF
MM Fibrous Board - Wall Register TOTAL ACM QUANTITIES: 462 SF
MM Lab Tables TOTAL ACM QUANTITIES: 50 SF
MM Ceiling Glue Pods TOTAL ACM QUANTITIES: 841 SF
MM Duct Putty TOTAL ACM QUANTITIES: 33 LF
MM Elevator Brake Pads TOTAL ACM QUANTITIES: 12 EA
Page: 12 of 111
VA Medical Center - Ann Arbor, MI - Sample Locator
SAMPLE NO NO HA MATL HA DESCRIPTION SAMPLE LOCATION RESULTS DUPLICATE
01-05-01-001 1 1 MM
1' x 1' Floor Tile, Cream w/ Brown
Streaks (light and dark)
Doorway, between Endoscopy Suite &
North Wing
ND
01-05-01-002 2 1 MM
1' x 1' Floor Tile, Cream w/ Brown
Streaks (light and dark)
Doorway, between Endoscopy Suite &
North Wing
ND
01-05-20-003 3 20 MM
1' x 1' Floor Tile, White w/ Grey
Flecks
Room A534 by Radiator, East End of
Room
ND
01-05-23-004 4 23 MM Mastic under HA # 20 Mastic under Sample #003 ND
01-05-21-005 5 21 MM 7" Brown Vinyl Cove Base Under Radiator on North Wall of Room
A534 A-534
ND
01-05-22-006 6 22 MM Mastic under HA # 21 Mastic under Sample #01-05-21-005 ND
01-05-24-007 7 24 MM
2' x 2' Ceiling Tile, White w/Random
Dotted Pattern, Smooth Finish Room A505 Ceiling over Sink, Kitchen ND
01-05-10-008 8 10 SM
Plaster on Expanded Wire Mesh
Ceiling
Room A505 Wall above Ceiling Tile, West
Wall
ND
01-05-54-009 9 54 MM Blue Check Wall Covering
Nurses' Computer Work Area, Under
Counter on Corridor Side, West Wing
A504
ND
01-05-02-010 10 2 MM 7" Black Vinyl Cove Base Corner Outside Room A533A ND
01-05-04-011 11 4 MM Mastic under HA # 2 Corner North "Jog" in Wall Outside
A533A
ND
01-05-24-012 12 24 MM
2' x 2' Ceiling Tile; White w/Random
Dotted Pattern, Smooth Finish
Room A526, 12' from East Wall, 8' from
South Wall
ND
01-05-01-013 13 1 MM
1' x 1' Floor Tile, Cream w/Brown
Streaks (light and dark)
Room A526, 12' from East Wall, 8' from
West Wall
ND
01-05-03-014 14 3 MM Mastic under HA # 1 Mastic under Sample #-1-05-01-013 ND
01-05-01-015 15 1 MM
1' x 1' Floor Tile, Cream w/Brown
Streaks (light and dark) Room A530, South Wall ND
01-05-55-016 16 55 MM Tan Cloth-Pattern Wall Covering Room A549, East Side, into Freight
Elevator Lobby @ 5.5"High
ND
01-05-10-017 17 10 SM
Plaster on Expanded Wire Mesh
Ceiling
Room A549, East Side of Doorway, into
Freight Elevator Lobby
ND
01-05-56-018 18 56 SM Plaster, White Finish Same as #016 ND
01-05-27-019 19 27 MM Linoleum, Brown Terrazzo Pattern Room A565 in Doorway to Adjoining
Room A564 40% Chrysotile
01-05-57-020 20 57 MM
Linoleum, Dark Brown Terrazzo
Pattern Room A562, Under Sink on East Wall 40% Chrysotile
Page: 13 of 111 June, 2019
01-05-24-021 21 24 MM
2' x 2' Ceiling Tile, White w/Random
Dotted Pattern, Smooth Finish Room A564, Ceiling Against East Wall ND
01-05-58-022 22 58 MM Drywall w/Mud & Tape Room A560A, Kitchen in ICU Wing
(during renovation activities)
ND
01-05-11-023 23 11 MM 6" Brown Vinyl Cove Base @ Corner in Corridor by A559 ND
01-05-12-024 24 12 MM Mastic under HA # 11 Same as #023 ND
01-05-59-025 25 59 MM Light Blue Wall Covering Walls of Corridors in ICU Wing ND
01-05-11-026 26 11 MM 6" Brown Vinyl Cove Base Room A573, Outside in Corridor Corner, South of Door Opening
ND
01-05-12-027 27 12 MM Mastic under HA # 11 Same as # 026 ND
01-05-02-028 28 2 MM 7" Black Vinyl Cove Base Room A573/A569 Where Rooms Meet on
South Wall Near 6-Outlet
ND
01-05-04-029 29 4 MM Mastic under HA # 2 Same as #028 ND
01-05-01-030 30 1 MM
1' x 1' Floor Tile, Cream w/Brown
Streaks (light and dark)
Room A586, West End Door Jamb under
Door 3% Chrysotile
01-05-03-031 31 3 MM Mastic under HA # 1 Same as #030 25% Chrysotile
01-05-58-032 32 58 MM Drywall w/Mud & Tape
Room A549B, Mechanical Room, North
Wall, Approx. Center, 2.5' off Floor, (behind compressor)
ND ND
01-05-01-033 33 1 MM
1' x 1' Floor Tile, Cream w/Brown
Streaks (light and dark) Room A549, in Doorway, East Side, Edge 2% Chrysotile
01-05-03-034 34 3 MM Mastic under HA # 1 Under #033 15% Chrysotile
01-05-55-035 35 55 MM Tan Cloth Pattern Wall Covering Room A542, to Left (north) of Entry ND
01-05-38-036 36 38 MM 7" Blue Vinyl Cove Base Room B531, West Side of Door ND
01-05-39-037 37 37 MM Mastic under HA # 36 Under Cove Base in Corridor @ Corner of
Nurse's Work Area
ND
01-05-38-038 38 38 MM 7" Blue Vinyl Cove Base Room B527, East Side (left) of Door ND
01-05-39-039 39 39 MM Mastic under HA # 38 Underneath #038 ND
01-05-02-040 40 2 MM 7" Black Vinyl Cove Base Room B257, Next to North Radiator, West Wall
ND
01-05-04-041 41 4 MM Mastic under HA # 2 Under Sample #040 ND
01-05-38-042 42 38 MM 7" Blue Vinyl Cove Base Room B513, Entrance, South Side of
Doorway
ND
01-05-39-043 43 39 MM Mastic under HA # 38 Under Sample #042 ND
01-05-13-044 44 13 MM
9" x 9" Floor Tile, Olive w/Brown &
White Streaks
Room B515, North Side of Doorway under
Door
ND
Page: 14 of 111 June, 2019
01-05-13-045 45 13 MM
9" x 9" Floor Tile, Olive w/Brown &
White Streaks
Room A504. Wing, Northeast Corner of
Nurses Work Station 2% Chrysotile
01-05-34-046 46 34 MM
1' x 1' Floor Tile, Tan w/Blue, Brown
& White Flecks
Room B541, North Edge of Doorway under Door
ND ND
01-05-36-047 47 36 MM 6" Tan Vinyl Cove Base Room B541, Corner by South End of "Jog" in Wall, Third Radiator from North End
ND
01-05-37-048 48 37 MM Mastic under HA # 36 Under Sample #047 ND ND
01-05-13-049 49 13 MM
9" x 9" Floor Tile, Olive w/Brown &
White Streaks
Room B521, Behind Door in Corner, Northwest Corner 2% Chrysotile
01-05-16-050 50 16 MM Mastic under HA # 13 Mastic under Sample #049 10% Chrysotile
01-05-19-051 51 19 MM
1' x 1' Ceiling Tile, Random Pattern, Smooth Finish, Glued On Room A534, Northwest Corner of Room ND ND
01-05-61-052 52 61 MM
Tan Cloth Wall Cover w/Wheat Head
Graphics
Room C503, Behind Railing on East Wall of Elevators in Northwest Corridor, 5th
Floor
ND
01-05-55-053 53 55 MM Tan Cloth Pattern Wall Covering Room A537, Lower Right Side o f Door ND
01-05-33-054 54 33 MM
2' x 2' Ceiling Tile, White w/Rough
Finish, Lay-In
Room 503, Elevator Lobby along East
Wall, South of Elevators, 7th Tile from
South End
ND
01-05-62-055 55 62 MM
Beige Cloth Wall Covering w/Horizontal Grain Room A538, West Wall Near Radiator ND
01-05-29-056 56 29 MM 4" Tan Vinyl Cove Base A538, Northwest Corner ND
01-05-30-057 57 30 MM Mastic under HA # 29 A538, Northwest Corner ND
01-05-33-058 58 33 MM
2' x 2' Ceiling Tile, White w/Rough
Finish, Lay-In
Room 503, Along North Wall of East/West
Corridor above Electric Closet
ND
01-05-33-059 59 33 MM
2' x 2' Ceiling Tile, White w/Rough
Finish, Lay-In
Southeast Corner above Doors into East
Wing
ND ND
01-05-19-060 60 19 MM
1' x 1' Ceiling Tile, Random Pattern, Smooth Finish, Glued On
Room A540, Along South Wall, Over
Book Shelf
ND
01-05-19-061 61 19 MM
1' x 1' Ceiling Tile, Random Pattern, Smooth Finish, Glued On
Room B501, Over Door Just Inside, Northeast Corner
Page: 15 of 111 June, 2019
01-05-07-062 62 7 MM
1' x 1' Floor Tile, Tan w/Brown &
White Streaks
Room A528, Corner Under Door, West
End Doorway 2% Chrysotile
01-05-07-063 63 7 MM
1' x 1' Floor Tile, Tan w/Brown &
White Streaks Room A521, Southeast Corner of Room ND ND
01-05-14-064 64 14 MM 4" Black Vinyl Cove Base Room A521, Northwest Corner of Room ND
01-05-15-065 65 15 MM Mastic under HA # 14 Mastic under Sample #064 ND
01-05-07-066 66 7 MM
1' x 1' Floor Tile, Tan w/Brown &
White Streaks Room A502, Northeast Corner ND
01-05-20-067 67 20 MM
1' x 1' Floor Tile, White w/Grey
Flecks
A535, East End of Doorway Directly under
Door
ND
01-05-20-068 68 20 MM
1' x 1' Floor Tile, White w/Grey
Flecks
Room B501A, South End Doorway
Directly under Door
ND
01-05-34-069 69 34 MM
1' x 1' Floor Tile, Tan w/Blue, Brown
& White Flecks
Room A542D, Along West Wall by
Doorway, (restroom off Endoscopy recovery)
ND ND
01-05-35-070 70 35 MM Mastic under HA # 34 Mastic under Sample #069 ND
01-05-31-071 71 31 MM 7" Grey Vinyl Cove Base Room B501, East Wall behind Door @
Jamb
ND
01-05-11-072 72 11 MM 6" Brown Vinyl Cove Base Room A530, West Wall behind Door under Sample #072
ND
01-05-12-073 73 12 MM Mastic under HA # 11 Under Sample #072 ND
01-05-21-074 74 21 MM 7" Brown Vinyl Cove Base Room A541, Behind North Door on West
Wall of Endoscopy Suite Entry Area
ND
01-05-22-075 75 22 MM Mastic under HA # 21 Mastic under Sample #074 ND
01-05-14-076 76 14 MM 4" Black Vinyl Cove Base Room A518, Behind Hinge Side of Door, North Wall
ND ND
01-05-15-077 77 15 MM Mastic under HA # 14 Mastic under #076 ND
01-05-11-078 78 11 MM 6" Brown Vinyl Cove Base Room A552A. North End, Northeast
Corner, North Wall
ND
01-05-12-079 79 12 MM Mastic under HA # 11 Mastic under Sample #078 ND
01-05-10-080 80 10 SM
Plaster on Expanded Wire Mesh
Ceiling Room A585, Above Ceiling Over Door ND ND
01-05-58-081 81 58 MM Drywall w/Mud & Tape Room A585, Above Ceiling Over Door ND
Page: 16 of 111 June, 2019
01-05-58-082 82 58 MM Drywall w/Mud & Tape Room A526, East Wall above Ceiling Tile, 5th Tile from North Wall
ND
01-05-10-083 83 10 SM
Plaster on Expanded Wire Mesh
Ceiling
Room A526, West Wall, 7th Tile from
North Wall
ND
01-02-79-084 84 79 MM
1' x 1' Floor Tile, Cream w/Caramel
Swirl Pattern
Room A265, Along South Wall, Near East
Most Radiator
ND
01-02-58-085 85 58 MM Drywall w/Mud & Tape Room A207, Above Doorway, above
Ceiling Tiles
ND
01-02-79-086 86 79 MM
1' x 1' Floor Tile, Cream w/Caramel
Swirl Pattern Room A215, Northwest Corner
Tile: ND
Mastic: 10% Chrysotile
01-02-80-087 87 80 MM Mastic under HA # 79 Mastic under #086 ND
01-02-80-088 88 80 MM Mastic under HA # 79 Room A265, Along South Wall, Near East
Most Radiator
ND
01-02-92-089 89 92 MM
Dark Blue Cloth Pattern Wall
Covering Room A238, Off West Wall ND
01-02-101-090 90 101 MM 9" x 9" Floor Tile, Darker Along North Wall Near Counter in Area of
Remodel, Taken from Patch Tiles
ND
01-02-102-091 91 102 MM
Blue Herringbone Pattern Wall
Cover North Side Wall in Cytology, Corridor C27 ND
01-02-81-092 92 81 MM
1' x 1' Floor Tile, Cream w/Caramel
Swirl Pattern
Room B211, #2 Next to Door Jamb, Northeast Corner
ND
01-02-13-093 93 13 MM
9" x 9" Floor Tile, Olive w/Brown &
White Streaks
Room B214, Operatory #5 under Counter, Northwest Corner of Floor
ND ND
01-02-77-094 94 77 MM
9" x 9" Floor Tile, Beige w/White
Streaks Room B214, Operatory #5, Under Chair
Tile: ND
Mastic: 10% Chrysotile
01-02-104-095 95 104 MM
Beige Wall Covering w/Mild White
Texture Room B242, Northeast Corner ND
01-02-107-096 96 107 MM
1' x 1' Floor Tile, Tan w/Brown &
Grey Flecks Room B283C, Next to Sink ND
01-02-08-097 97 8 MM Mastic under HA # 7 Room B202, Floor Along South Wall, About in Middle
ND
01-02-60-098 98 60 MM
Vibration Damper Connection on
HVAC Duct (expansion joint grey woven material)
Room B230E @ Duct Junction 80% Chrysotile
Page: 17 of 111 June, 2019
01-03-110-99 99 110 SM White Rolled-On Ceiling Texture Room A333, Southeast Corner above Door ND
01-05-40-100 100 40 TSI CWS Fittings >2" - <6" Diameter Room B5ME01, 20" from East Wall, 20" from North Wall, 7' from Floor
ND
01-05-40-101 101 40 TSI CWS Fittings >2" - <6" Diameter Room B5ME01, 22' from East Wall, 12' from North Wall, 3' from Floor 20% Chrysotile
01-05-40-102 102 40 TSI CWS Fittings >2" - <6" Diameter Room B5ME01, 26' from East Wall, 12' from North Wall, 7' from Floor 10% Chrysotile
01-05-41-103 103 40 TSI CWS Fittings >2" - <6" Diameter Room B5ME01, 14' from East Wall, 10' from North Wall, 3' from Floor
ND
01-05-41-104 104 41 TSI HWS Fittings <2" Diameter Room B5ME01, 10' from East Wall, 24' from North Wall, 4' from Floor
ND
01-05-41-105 105 41 TSI HWS Fittings <2" Diameter Room B5ME01, 30' from East Wall, 24' from North Wall, 4' from Floor
ND
01-05-42-106 106 42 TSI HWS Fittings <2" Diameter Room B5ME01, 31' from East Wall, 24' from North Wall, 7' from Floor
ND
01-05-42-107 107 42 TSI HWS Fittings <2" Diameter Room B5ME01, 11' from East Wall, 24' from North Wall, 5' from Floor
ND
01-05-42-108 108 42 TSI HWS Fittings <2" Diameter Room B5ME01, 18' from East Wall, 2' from North Wall, 6' from Floor
ND
01-05-43-109 109 43 TSI Drip Return Fittings <2" Diameter Room B5ME01, 44' from East Wall, 16' from North Wall, 2' from Floor
ND
01-05-43-110 110 43 TSI Drip Return Fittings <2" Diameter Room B5ME01, 44' from, East Wall, 20' from North Wall, 6' from Floor
ND
01-05-43-111 111 43 TSI Drip Return Fittings <2" Diameter Room B5ME01, 41' from East Wall, 20' from North Wall, 7' from Floor
ND
01-05-46-112 112 46 TSI LPS Fittings, >2" - <6" Diameter Room B5ME01, 41' from East Wall, 20' from North Wall, 5' from Floor
ND
01-05-45-113 113 43 TSI Drip Return Fittings <2" Diameter Room B5ME01, 39' from East Wall, 10' from North Wall, 4' from Floor
ND
01-05-45-114 114 45 TSI LPS Fittings, >2" - <6" Diameter Room B5ME01, 10' from East Wall, 16' from North Wall, 7' from Floor 40% Chrysotile
01-05-60-115 115 60 MM
Vibration Damper Connection on
HVAC Duct (expansion joint grey woven material)
Room B5ME01, 16' from East Wall, 4' from South Wall, 4' from Floor, Zone 6, or
Room 431
80% Chrysotile
01-05-50-116 116 50 TSI Condensate Fittings <2" Diameter Room B5ME01, 3' from East Wall, 30' from North Wall, 4' from Floor
ND ND
Page: 18 of 111 June, 2019
01-05-50-117 117 50 TSI Condensate Fittings <2" Diameter Room B5ME01, 14' from East Wall, 3' from South Wall, 3' from Floor 40% Chrysotile 15% Chrysotile
01-05-50-118 118 50 TSI Condensate Fittings <2" Diameter Room B5ME01, 14' from, East Wall, 3' from North Wall, 2' from Floor
ND
01-05-44-119 119 44 TSI
LPS Straight Runs on Pipes <2"
Diameter
Room B5ME01, 6' from East Wall, 22' from North Wall, 9' from Floor
20% Amosite
40% Chrysotile
01-05-46-120 120 46 TSI LPS Fittings, >2" - <6" Diameter Room B5ME01, 24' from East Wall, 20' from North Wall, 6' from Floor
ND ND
01-05-46-121 121 46 TSI LPS Fittings, >2" - <6" Diameter Room B5ME01, 41' from East Wall, 14' from North Wall, 5' from Floor
ND
01-05-45-122 122 45 TSI LPS Fittings <2" Diameter Room B5ME01, 41' from East Wall, 11' from North Wall, 5' from Floor
ND
01-05-53-123 123 53 TSI
Make-Up Water Straight Runs <2"
Diameter
Room B5ME01, 38' from East Wall, 12' from North Wall, 8' from Floor 20% Chrysotile
01-05-51-124 124 51 TSI
Make-Up Water Fittings <2"
Diameter
Room B5ME01, 38' from East Wall, 13' from North Wall, 7' from Floor
ND
01-05-51-125 125 51 TSI
Make-Up Water Fittings <2"
Diameter
Room B5ME01, 31' from East Wall, 24' from North Wall, 2' from Floor 60% Chrysotile
01-05-18-126 126 18 TSI
Mudded Pipe Fittings on Domestic
Water Lines; <2" Diameter. Pipes
Room A529, 7' from East Wall, 5' from
North Wall, 9' from Floor 50% Chrysotile
01-05-51-127 127 51 TSI
Make-Up Water Fittings <2"
Diameter
Room B5ME01, 38' from East Wall, 21' from North Wall, 8' from Floor 60% Chrysotile
01-05-53-128 128 53 TSI
Make-Up Water Straight Runs <2"
Diameter
Room E5ME01, 38' from East Wall, 20' from North Wall, 8' from Floor 5% Chrysotile
01-05-53-129 129 53 TSI
Make-Up Water Straight Runs <2"
Diameter
Room B5ME01, 31' from East Wall, 24' from North Wall, 2' from Floor 80% Chrysotile
01-05-47-130 130 47 TSI MPS Fittings <2" Diameter Room B5ME01, 9' from East Wall, 23' from North Wall, 6' from Floor
ND
01-05-47-131 131 47 TSI MPS Fittings <2" Diameter Room B5ME01, 8' from East Wall, 3' from
South Wall, 4' from Floor 30% Chrysotile
01-05-47-132 132 47 TSI MPS Fittings <2" Diameter Room B5ME01, 17' from East Wall, 3' from North Wall, 4' from Floor
ND
01-05-48-133 133 48 TSI MPS Vessel Mud Insulation Room B5ME01, 15' from East Wall, 2' from North Wall, 4' from Floor
ND ND
01-05-49-134 134 49 TSI HWR Vessel Mud Insulation Room B5ME01, 16' from East Wall, 4' from North Wall, 5' from Floor
Page: 19 of 111 June, 2019
01-05-52-135 135 52 TSI CWS Vessel Mud Insulation Room B5ME01, 21' from East Wall, 6' from North Wall, 3' from Floor
ND
01-05-06-136 136 6 TSI
Mudded Pipe Fittings on Steam
Lines, <2" Diameter Pipes
Room526, 1' from North Wall, 13' from
West Wall, 9' from Floor 20% Chrysotile
01-05-09-137 137 9 TSI
Insulation on Domestic Pipe Straight
Runs, <2" Diameter Pipes
Room A529, 7' from East Wall, 6' from
North Wall, 9' from Floor by Shower above Access Panel
ND
01-05-09-138 138 9 TSI
Insulation on Domestic Pipe Straight
Runs, <2" Diameter Pipes
Room A529, 7' from East Wall, 6' from
North Wall, 9' from Floor by Shower above Access Panel
ND
01-05-18-139 139 18 TSI
Mudded Pipe Fittings on Domestic
Water Lines, <2" Diameter Pipes
Room, A529, 6' from East Wall, 5' from
North Wall, 9' from Floor 30% Chrysotile
01-05-18-140 140 18 TSI
Mudded Pipe Fittings on Domestic
Water Lines, <2" Diameter Pipes
Room A584, West Wing above Ceiling
Tile, 3' from North Wall, 2' from West
Wall, 9' from Floor
ND
01-05-06-141 141 6 TSI
Mudded Pipe Fittings on Steam
Lines, <2" Diameter Pipes
Room A584, West Wing above Ceiling
Tile, 6' from East Wall, 1' from South
Wall, 9' from Floor
80% Chrysotile 80% Chrysotile
01-05-06-142 142 6 TSI
Mudded Pipe Fittings on Steam
Lines, <2" Diameter Pipes
Room A573, West Wing above CT, 2' from West Wall, 3' from South Wall, 9' from Floor
60% Chrysotile
01-05-09-143 143 9 TSI
Insulation on Domestic Pipe Straight
Runs,…
This is the start of the file's text. The full file is on GovTribe.