SD321216-01.pdf
PDF 84 KB Posted
- Attached to
- Install Car Charging Stations Project #539-21-203 at the Cincinnati VAMC, Cincinnati, OH
- Solicitation number
- 36C25021B0013
About this file
This document outlines a federal contract opportunity for installation services. The contractor shall install car charging stations at two Department of Veterans Affairs locations in Cincinnati, Ohio and Fort Thomas, Kentucky. The period of performance is 180 calendar days from receipt of the notice to proceed, with an estimated value between $5 million and $10 million. The NAICS code is 236220 for residential building construction with a size standard of $39.5 million. The bid opening will take place virtually on the specified date and time at the Network Contracting Office in Cincinnati. An organized pre-bid site visit is scheduled for February 24, 2021. This is a 100% set-aside for service-disabled veteran-owned small businesses listed on the VA Vendor Information Pages database. Bidders must have their temperature checked and wear masks for the site visit.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25021B0013 0005.docx | DOCX document | |
| 36C25021B0013 0004.docx | DOCX document | |
| SD321216-02.pdf | ||
| 36C25021B0013 0003.docx | DOCX document | |
| 36C25021B0013 0002.docx | DOCX document | |
| 539-21-203_ ADDENDUM_1-write up -2021.0304.pdf | ||
| 539-21-203 drawings -addendum1 2021.03.pdf | ||
| 36C25021B0013 0001.docx | DOCX document | |
| Site Visit 2.24.2021.pdf | ||
| 36C25021B0013_1.docx | DOCX document | |
| Attachment 2- SPECIFICATONS.pdf | ||
| Attachment 3 -Contractor EMR Certification Form.pdf | ||
| Attachment 1 - DRAWINGS.pdf | ||
| Attachment 5-DBA-WD-OH020210082.pdf | ||
| Attachmetn 4- RFI Form.pdf |
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FOR TRENCH WIDTHS EXCEEDING 4' [1219mm] REFER TO VA
STANDARD DETAIL 32 12 16-02 "TYPE 2 UTILITY TRENCH PATCH".
FOR TRENCH WHERE PORTLAND CEMENT CONCRETE (PCC) PAVEMENT
EXISTS, REFER TO 32 12 16-03 "TYPE 3 UTILITY TRENCH PATCH".
2" [50mm] MINIMUM OR THICKNESS OF EXISTING PAVEMENT
WHICHEVER IS GREATER.
BITUMINOUS SURFACE TREATMENT (CHIPSEAL) REQUIRED ONLY FOR
LONGITUDINAL TRENCHES WITH WIDTHS GREATER THAN 6' [1829mm].
4" [100mm] MINIMUM ABC OR THICKNESS OF EXISTING GRANULAR
BASE COURSE MATERIALS (E.G. ABC & SELECT MATERIAL) WHICHEVER
IS GREATER.
REFER TO VA STANDARD DETAIL 32 12 16-04 "UTILITY TRENCH
PAVEMENT PATCH NOTES" FOR ADDITIONAL INFORMATION.
TYPE 1 UTILITY TRENCH PATCH
NTS
4'-0" MAX.
[1219mm]
1'-0" MAX.
[305mm]
1'-0" MAX.
[305mm]
TRENCH
BACKFILL
ABC 100% MIN.
COMPACTION
ASPHALTIC CONCRETE
SAW CUT EXISTING.
ASPHALT FULL
DEPTH BOTH SIDESTACK COAT (TYP.)
EXISTING
PAVEMENT
SCALE :
CAD DETAIL NO.: DATE ISSUED:
DETAIL TITLE / TYPE 1 UTILITY TRENCH PATCH
SD321216-01.DWGDECEMBER 2008
NONE
8.5x11