36C25020B0018-072.pdf

PDF Posted

Attached to
Renovate Space for VCC 583-15-112 (VA-20-00021374)
Solicitation number
36C25020B0018
Issued by

About this file

This solicitation notice provides details for an upcoming construction project at the Richard L. Roudebush VA Medical Center in Indianapolis, Indiana. The project involves renovating space for the Veterans Choice Program and includes updating the library and computer training rooms on the second floor of the A-Wing building. Work will include general construction, alterations, electrical, fire protection, mechanical, plumbing and necessary demolition. The project size is estimated between $1 million to $5 million. The solicitation will be set aside 100% for Service Disabled Veteran-Owned Small Businesses and will be issued on or around February 3, 2020 via beta.sam.gov. Interested offerors should attend an optional pre-solicitation site visit. The point of contact for questions is Jeff Hairston, Contract Specialist at the VA North Central Ohio healthcare system.

36C25020B0018 28 583-15-112 MH103.pdf

View the file

Other files

File Type Posted
36C25020B0018-0007000.docx DOCX document
36C25020B0018-0006001.docx DOCX document
36C25020B0018-0006000.docx DOCX document
36C25020B0018-0006002.pdf PDF
36C25020B0018-0005001.pdf PDF
36C25020B0018-0005000.docx DOCX document
36C25020B0018-0004001.pdf PDF
36C25020B0018-0004000.docx DOCX document
36C25020B0018-0003000.docx DOCX document
36C25020B0018-0003001.pdf PDF
36C25020B0018-0003002.pdf PDF
36C25020B0018-0003003.pdf PDF
36C25020B0018-0003004.pdf PDF
36C25020B0018-0002003.pdf PDF
36C25020B0018-0002004.jpg JPG image
36C25020B0018-0002005.pdf PDF
36C25020B0018-0002001.docx DOCX document
36C25020B0018-0002000.docx DOCX document
36C25020B0018-0002002.pdf PDF
36C25020B0018-0001000.docx DOCX document
36C25020B0018-053.pdf PDF
36C25020B0018-046.pdf PDF
36C25020B0018-061.pdf PDF
36C25020B0018-067.pdf PDF
36C25020B0018-050.pdf PDF
36C25020B0018-062.pdf PDF
36C25020B0018-077.pdf PDF
36C25020B0018-045.pdf PDF
36C25020B0018-070.pdf PDF
36C25020B0018-066.pdf PDF
36C25020B0018-071.pdf PDF
36C25020B0018-051.pdf PDF
36C25020B0018-064.pdf PDF
36C25020B0018-076.pdf PDF
36C25020B0018-048.pdf PDF
36C25020B0018-054.pdf PDF
36C25020B0018-058.pdf PDF
36C25020B0018-049.pdf PDF
36C25020B0018-068.pdf PDF
36C25020B0018-047.pdf PDF
36C25020B0018-041.doc DOC document
36C25020B0018-056.pdf PDF
36C25020B0018-069.pdf PDF
36C25020B0018-060.pdf PDF
36C25020B0018-063.pdf PDF
36C25020B0018-074.pdf PDF
36C25020B0018-052.pdf PDF
36C25020B0018-055.pdf PDF
36C25020B0018-059.pdf PDF
36C25020B0018-040.docx DOCX document
Show 40 more

Latest 50 of 57 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EXISTING

INTERSTITIAL

SPACE

AREA #1

EXISTING

INTERSTITIAL

SPACE

AREA #2

1 11 1 1

111111

All concepts, ideas, design elements, plans, and details as shown on this document are the sole property of Viridian Architectural Design Inc. and shall not be used for any purpose without prior expressed written consent. The Contracting Officer Representative shall be permitted to retain copies for information and reference.

2020 E. Washington Boulevard Suite 200 Fort Wayne, Indiana 46803

PH: 260.424.4830

www.viridian-design.netV IRIDIAN

ARCHITECTURAL DESIGN INC.

SCALE: 1/4" = 1'-0"

MECHANICAL - THIRD FLOOR PLAN

MH103

BALANCE EXISTING TERMINAL UNIT FOR CFM INDICATED ON DRAWINGS. REFER TO

MH102 FOR ADDITIONAL INFORMATION.

PROVIDE AND INSTALL AIRTIGHT SEALED CAP ON EXISTING DUCTWORK.

1. COORDINATE ALL WORK WITH OTHER TRADES AS REQUIRED.

2. EQUIPMENT, PIPING, AND DUCTWORK LAYOUTS ARE SCHEMATIC IN NATURE.

CONTRACTOR MUST ADJUST TO FIELD CONDITIONS AND COORDINATE WITH OTHER

TRADES DURING CONSTRUCTION BY ADDING OFFSETS AND ELBOWS WHERE

REQUIRED.

3. PRIOR TO INSTALLATION THE ENGINEER SHALL APPROVE ALL PROPOSED

MODIFICATIONS TO DUCTWORK LAYOUT AND DESIGN.

4. ALL SUPPLY AIR DUCTWORK SHALL BE INSULATED (WRAPPED) PER SPECIFICATIONS.

5. ALL MATERIALS INSTALLED WITHIN PLENUM SHALL HAVE A FLAME SPREAD RATING OF

NOT MORE THAN 25, SMOKE DEVELOPED RATING NOT EXCEEDING 50 IN

ACCORDANCE WITH STATE CODES.

6. COORDINATE EXACT LOCATION OF CEILING DIFFUSERS AND GRILLES WITH LIGHTS

AND ARCHITECTURAL CEILING PLAN.

7. FLEXIBLE DUCT SHALL BE USED WHERE INDICATED, FOR STRAIGHT LINE SEGMENTS

NOT EXCEEDING 6 FEET WHEN CONNECTING DIFFUSERS TO RIGID DUCTWORK ABOVE

A REMOVABLE CEILING. USE RIGID METAL ELBOWS FOR CHANGES IN DIRECTION.

8. THIS CONTRACTOR SHALL PROVIDE ALL EQUIPMENT, MATERIAL, AND LABOR

REQUIRED FOR CORE DRILLING AS REQUIRED FOR INSTALLATION OF MATERIAL

PENETRATING BUILDING CONSTRUCTION.

9. REFERENCE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS, TYPICAL.

10. ALL SIZES ON DUCTWORK ARE IN INCHES UNLESS NOTED OTHERWISE.

11. SHEET METAL CONTRACTOR SHALL FABRICATE ALL DUCT TAKE-OFF FITTINGS AS

SHOWN ON CONTRACT DETAIL SHEET.

12. DUCT SIZES LISTED ARE "FREE AREA" AND SHALL NOT BE REDUCED.

NOT TO SCALE

THIRD FLOOR KEY PLAN

N

RICHARD L. ROUDEBUSH

VA MEDICAL CENTER

D-WING

C-WING

A-WING

RENOVATION

AREA

NOTE:

PROVIDE FIRE STOPPING AT ALL NEW PENETRATIONS OF FLOOR. PATCH ALL

ABANDONED OPENINGS AND MAINTAIN FIRE RATING OF FLOOR.

Sheets and Views
MH103

File details come from the government source that posted it. Updated .