36C25020B0018-063.pdf
PDF Posted
- Solicitation number
- 36C25020B0018
About this file
This document contains plans and specifications for a construction project renovation at the Richard L. Roudebush VA Medical Center in Indianapolis, Indiana. The project involves renovating space for a Veterans Crisis Center, including updating the library, computer training rooms, and simulation labs. Work includes alterations, electrical, fire protection, mechanical and plumbing systems. The project will be procured as 100% set-aside for Service-Disabled Veteran-Owned Small Businesses. The solicitation is expected to be issued on or about February 3, 2020 via SAM.gov. The construction value is estimated between $1-5 million. Interested contractors should contact Jeff Hairston for additional details.
36C25020B0018 19 583-15-112 PD102.pdf
View the file
Other files
Show 40 more
Latest 50 of 57 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONSTRUCTION LIMIT LINE
CONSTRUCTION LIMIT LINE
CONSTRUCTION LIMIT LINE CONSTRUCTION LIMIT LINE
CONSTRUCTION LIMIT LINE
CO
NS
TR
UC
TIO
N
LIM
IT
LIN
E
CO
NS
TR
UC
TIO
N
LIM
IT
LIN
E
CO
NS
TR
UC
TIO
N
LIM
IT
LIN
E
CO
NS
TR
UC
TIO
N
LIM
IT
LIN
E
CO
NS
TR
UC
TIO
N
LIM
IT
LIN
E
CONSTRUCTION LIMIT LINE
CONSTRUCTION LIMIT LINE
CONSTRUCTION LIMIT LINE
CONSTRUCTION LIMIT LINE
CONSTRUCTION LIMIT LINE CONSTRUCTION LIMIT LINE
CO
NS
TR
UC
TIO
N
LIM
IT
LIN
E
CO
NS
TR
UC
TIO
N
LIM
IT
LIN
E
CO
NS
TR
UC
TIO
N
LIM
IT
LIN
E
CO
NS
TR
UC
TIO
N
LIM
IT
LIN
E
CO
NS
TR
UC
TIO
N
LIM
IT
LIN
E
CO
NS
TR
UC
TIO
N
LIM
IT
LIN
E
CO
NS
TR
UC
TIO
N
LIM
IT
LIN
E
CO
NS
TR
UC
TIO
N
LIM
IT
LIN
E
CO
NS
TR
UC
TIO
N
LIM
IT
LIN
E
EXISTING
CIVCC CLASSROOM
A-2009B
EXISTING
CIVCC CLASSROOM
A-2009B
EXISTING
WORKROOM
A-2020
EXISTING
PHOTO COPY
A-2012
EXISTING
STORAGE
A-2010
EXISTING
AUDIO VISUAL ROOM
A-2021
EXISTING
SIM LAB
A-2023
EXISTING
ROOM
A-2018
EXISTING
OFFICES
A-2014
EXISTING
HEALTHY LIVING
CLASSROOM
A-2015
EXISTING
ELEV.
P-16
EXISTING
STAIRS
#13-2
EXISTING
LOBBY
C2-14
CUSTOMER SERVICE
EXISTING
CUSTOMER SERVICE
SECRETARY
A-2006A
EXISTING
MECHANICAL ROOM
A-2010
EXISTING
ELECTRICAL ROOM
EXISTING
ELECTRICAL STORAGE
INSTRUCTOR'S
PLATFORM
EXISTING
COMPUTER ROOM #2
A-2008
EXISTING
COMPUTER ROOM #1
A-2007
EXISTING
CIRCULATION DESK
A-2019
EXISTING
OFFICE
A-2017
EXISTING
SIM OBSERVATION
A-2022
EXISTING
LIBRARY
A-2009
1 HOUR FIRE 1 HOUR FIRE
1 HOUR FIRE 1 HOUR FIRE 1 HOUR FIRE
H
O U R
FIR
E H
O U R
FIR
E
H
O U R
FIR
E
1 HOUR FIRE 1 HOUR FIRE 1 HOUR FIRE 1 HOUR FIRE 1 HOUR FIRE 1 HOUR FIRE 1 HOUR FIRE 1 HOUR FIRE 1 HOUR FIRE 1 HOUR FIRE 1 HOUR FIRE 1 HOUR FIRE 1 HOUR FIRE 1 HOUR FIRE 1 HOUR FIRE 1 HOUR FIRE 1 HOUR FIRE
1 HOUR FIRE 1 HOUR FIRE 1 HOUR FIRE 1 HOUR FIRE
1 HOUR FIRE
H
O U R F
IR
E
H
O U R F
IR
E
H
O U R F
IR
E
H
O U R F
IR
E
H
O U R F
IR
E
H
O U R F
IR
E
H
O U R
FIR
E
2 HOUR FIRE
H
O U R F
IR
E
2 HOUR FIRE
UP (RAMP)
TV
TV
TV
TV
All concepts, ideas, design elements, plans, and details as shown on this document are the sole property of Viridian Architectural Design Inc. and shall not be used for any purpose without prior expressed written consent. The Contracting Officer Representative shall be permitted to retain copies for information and reference.
2020 E. Washington Boulevard Suite 200 Fort Wayne, Indiana 46803
PH: 260.424.4830
www.viridian-design.netV IRIDIAN
ARCHITECTURAL DESIGN INC.
SCALE: 1/4" = 1'-0"
PLUMBING - DEMOLITION - SECOND FLOOR PLAN
PD102
REMOVE PLUMBING FIXTURE COMPLETE. REMOVE CW, HW, SANITARY, AND VENT
PIPING IN WALL COMPLETELY. REFER TO PD103 FOR CONTINUATION OF WORK.
REMOVE SANITARY PIPING THROUGH FLOOR AND PATCH FLOOR. REMOVE SANITARY
PIPING IN CEILING OF FIRST FLOOR AND PREPARE FOR RECONNECTION. FIRST FLOOR
SPACE BELOW IS THE EMERGENCY DEPARTMENT. WORK ON THE FIRST FLOOR IS TO
BE SCHEDULED WITH THE COR.
THESE NOTES APPLY TO ALL DEMOLITION DRAWINGS AND TO ALL CONTRACTORS AND/OR
SUBCONTRACTORS THAT WORK WITHIN THIS BUILDING.
1. ALL MATERIALS INDICATED AS DASHED ARE TO BE REMOVED. THIS INCLUDES ALL
FINISHES AND MATERIALS NOT SPECIFICALLY CALLED OUT BUT PERTAINING TO THE
INTENDED SCOPE.
2. CONTRACTORS SHALL BE RESPONSIBLE FOR VISITING THE SITE TO BECOME FAMILIAR
WITH THE EXISTING CONDITIONS. THESE DEMOLITION SHEETS SHALL SERVE TO AID THE
CONTRACTOR IN THE EVALUATION OF THE EXTENT OF DEMOLITION: BUT SHALL NOT BE
HELD TO BE ALL INCLUSIVE.
3. CONTRACTORS SHALL FIELD INSPECT ALL DEMOLITION WORK PRIOR TO REMOVAL, TO
ENSURE SUCH REMOVAL DOES NOT IMPAIR STRUCTURAL INTEGRITY OF THE EXISTING
SITE OR BUILDING. IF THE INSPECTION INDICATES THAT THE STRUCTURAL INTEGRITY
MAY BE COMPROMISED, NOTIFY THE CONTRACTING OFFICER REPRESENTATIVE (COR)
IMMEDIATELY.
4. GENERAL CONTRACTOR TO COORDINATE ALL ASSOCIATED WORK WITH ALL
SUB-CONTRACTORS.
5. ALL CONTRACTORS TO VERIFY STAGING AND STORAGE LOCATIONS OF ALL MATERIALS
AND EQUIPMENT WITH COR PRIOR TO BEGINNING OF CONSTRUCTION.
6. ALL CONSTRUCTION AREAS AND ASSOCIATED WORK AREAS SHALL BE KEPT CLEAN BY
THE CONTRACTOR - DAILY.
7. PROTECT ADJACENT SPACES AND EXISTING EQUIPMENT FROM DEMOLITION DEBRIS
AND DAMAGE DURING CONSTRUCTION.
8. CONTRACTOR TO ENSURE NO DEMOLITION DEBRIS IS LEFT ON SITE PRIOR TO
COMPLETING ALL DEMOLITION WORK.
9. ALL CONTRACTORS SHALL BE RESPONSIBLE FOR ANY DAMAGES CAUSED BY THEM
DURING THE CONSTRUCTION PROCESS. IN THE EVENT OF ANY DAMAGES CONTRACTOR
IS TO CONTACT THE COR IMMEDIATELY; PRIOR TO THE END OF THE DAY OF
CONSTRUCTION.
10. ALL CONTRACTORS TO COORDINATE RELOCATION AND STORAGE OF EXISTING AND
DEMOLISHED EQUIPMENT AND MATERIALS WITH THE COR PRIOR TO THE START OF
CONSTRUCTION.
NOT TO SCALE
SECOND FLOOR KEY PLAN
RICHARD L. ROUDEBUSH
VA MEDICAL CENTER
N
D-WING
C-WING
A-WING
RENOVATION
AREA
NOTE:
PATCH AND SEAL ALL UNUSED OPENINGS IN FLOOR TO MAINTAIN FIRE RATING OF
FLOOR.
NOTE:
CONTRACTOR TO TAKE CAUTION NOT TO DAMAGE ANY EXISTING FINISHES. ALL
DAMAGED FINISHED TO BE REPAIRED TO SHOW NO EVIDENCE OF CONSTRUCTION AT
NO ADDITIONAL COST TO VA.
| Sheets and Views |
| PD102 |
File details come from the government source that posted it. Updated .