36C25018B0581-004.pdf
PDF 5 MB Posted
- Attached to
- Add Domestic Water Pressure Booster Project: 757-19-203 Chalmers P. Wylie VAACC Columbus, Ohio 43219-1834
- Solicitation number
- 36C25018B0581
About this file
36C25018B0581 Domestic Water Pump - Drawings (Revised 3-30-18).pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25018C0217-000.docx | DOCX document | |
| 36C25018B0581-006.pdf | ||
| 36C25018B0581-005.docx | DOCX document | |
| 36C25018B0581-0002000.docx | DOCX document | |
| 36C25018B0581-0002001.pdf | ||
| 36C25018B0581-0001000.docx | DOCX document | |
| 36C25018B0581-003.pdf | ||
| 36C25018B0581-002.pdf | ||
| 36C25018B0581-001.docx | DOCX document | |
| 36C25018B0581-000.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
System No. C-AJ-5091
SECTION A-A
1. Floor or Wall Assembly — Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m³) concrete. Wall may also be constructed of any UL Classified Concrete Blocks*. Max diam of opening is 29 in. (737 mm).
See Concrete Blocks (CAZT) category in the Fire Resistance directory for names of manufacturers.
2. Metallic Sleeve — (Optional) — Nom 30 in. (762 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe sleeve cast or grouted into floor or wall assembly, flush with floor or wall surfaces or extending a max of 3 in. (76 mm) above floor or beyond both surfaces of wall. If the steel sleeve extends beyond the top surface of the floor or both surfaces of the wall, the T Rating of the firestop system is 0 hr.
2A. Sheet Metal Sleeve — (Optional) - Max 6 in. (152 mm) diam, min 26 ga galv steel provided with a 26 ga galv steel square flange spot welded to the sleeve at approximately mid- height, or flush with bottom of sleeve in floors, and sized to be a min of 2 in. (51 mm) larger than the sleeve diam.
The sleeve is to be cast in place flush with bottom surface of floor and may extend a max of 1 in. (25 mm) above the top surface of the floor.
2B. Sheet Metal Sleeve — (Optional) - Max 12 in. (305 mm) diam, min 24 ga galv steel provided with a 24 ga galv steel square flange spot welded to the sleeve at approximately mid- height, or flush with bottom of sleeve in floors, and sized to be a min of 2 in. (51 mm) larger than the sleeve diam. The sleeve is to be cast in place flush with bottom surface of floor and may extend a max of 1 in. (25 mm) above the top surface of the floor.
3. Through Penetrants — One metallic pipe or tubing to be installed either concentrically or eccentrically within the firestop system. Pipe or tubing to be rigidly supported on both sides of floor or wall assembly. The following types and sizes of metallic pipes or tubing may be used:
A. Steel Pipe — Nom 12 in. (305 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe.
B. Iron Pipe — Nom 12 in. (305 mm) diam (or smaller) cast or ductile iron pipe.
C. Copper Pipe — Nom 6 in. (152 mm) diam (or smaller) Regular (or heavier) copper pipe.
D. Copper Tubing — Nom 6 in. (152 mm) diam (or smaller) Type L (or heavier) copper tubing.
4. Pipe Covering — Min 1/2 in. (13 mm) to max 2 in. (51 mm) thick hollow cylindrical heavy density (min 3.5 pcf or 56 kg/m³) glass fiber units jacketed on the outside with an all-service jacket. Longitudinal joints sealed with metal fasteners or factory-applied, self-sealing lap tape.
Transverse joints secured with metal fasteners or with butt tape supplied with the product. The annular space between the insulated pipe and the edge of the periphery of the opening shall be min 1/2 in. (13 mm) to max 12 in. (305 mm). When thickness of pipe covering is less than 2 in. (51 mm), the T Rating for the firestop system is 0 hr.
See Pipe Equipment Covering — Materials — (BRGU) category in the Building Materials Directory for names of manufacturers. Any pipe covering material meeting the above specifications and bearing the UL Classification Marking with a Flame Spread Index of 25 or less and a Smoke Developed Index of 50 or less may be used.
4A. Pipe Covering — (Not Shown) — As an alternate to Item 4, max 2 in. (51 mm) thick cylindrical calcium silicate (min 14 pcf or 224 kg/m³) units sized to the outside diam of the pipe or tube may be used. Pipe insulation secured with stainless steel bands or min 18 AWG stainless steel wire spaced max 12 in. (305 mm) OC. The annular space shall be min 1/2 in. (13 mm) to max 12 in. (305 mm).
5. Firestop System — The firestop system shall consist of the following:
A. Packing Material — Min 4 in. (102 mm) thickness of min 4 pcf (64 kg/m³) mineral wool batt insulation firmly packed into opening as a permanent form. Packing material to be recessed from top surface of floor or from both surfaces of wall as required to accommodate the required thickness of fill material.
B. Fill, Void or Cavity Material* — Sealant — Min 1/2 in. (13 mm) thickness of fill material applied within the annulus, flush with top surface of floor or with both surfaces of wall.
HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-One Sealant or FS-ONE MAX Intumescent Sealant
* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively.
A
A
5B
5A
C
CL
ASS I F IED
Classified by Underwriters Laboratories, Inc.
to UL 1479 and CAN/ULC-S115
US
Hilti Firestop Systems
Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc.
January 13, 2015
ANSI/UL1479 (ASTM E814) CAN/ULC S115
F Rating — 2 Hr F Rating — 2 Hr
T Ratings — 0 and 1 Hr (See Items 2 and 4)
FT Ratings — 0 and 1 Hr (See Items 2 and 4)
L Rating At Ambient — 4 CFM/sq ft FH Rating — 2 Hr
L Rating At 400 F — Less Than 1 CFM/sq ft
FTH Ratings — 0 and 1 Hr (See Items 2 and 4)
L Rating At Ambient —4 CFM/sq ft
L Rating At 400 F —Less Than 1 CFM/sq ft
System No. C-AJ-1421
SECTION A-A
A
Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc.
January 28, 2015
A
C
CL
ASS I F IED
Classified by Underwriters Laboratories, Inc.
to UL 1479 and CAN/ULC-S115
US
Hilti Firestop Systems
1. Floor or Wall Assembly — Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m³) concrete. Wall may also be constructed of any UL Classified Concrete Blocks*. Max diam of opening is 6 in. (152 mm).
See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manufacturers.
2. Metallic Sleeve — (Optional) Nom 6 in. (152 mm) diam (or smaller) Schedule 40 (or heavier) steel sleeve cast or grouted into floor or wall assembly, flush with floor or wall surfaces.
3. Through-Penetrant — One metallic pipe or conduit to be installed either concentrically or eccentrically within the firestop system. The annular space between pipe, tube or conduit and periphery of opening shall be min 0 in. (point contact) to max 5-3/8 in. (137 mm). Pipe or conduit to be rigidly supported on both sides of floor or wall assembly. The following types and sizes of metallic pipes or conduits may be used:
A. Steel Pipe — Nom 4 in. (102 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe.
B. Iron Pipe — Nom 4 in. (102 mm) diam (or smaller) cast or ductile iron pipe.
C. Copper Pipe — Nom 4 in. (102 mm) diam (or smaller) Regular (or heavier) copper pipe.
D. Copper Tubing — Nom 4 in. (102 mm) diam (or smaller) Type L (or heavier) copper tubing.
E. Conduit — Nom 4 in. (102 mm) diam (or smaller) steel conduit.
F. Conduit — Nom 4 in. (102 mm) diam (or smaller) steel electrical metallic tubing (EMT).
4. Firestop System — The firestop system shall consist of the following:
A. Packing Material — Min 4 in. (102 mm) thickness of min 4 pcf (64 kg/m³) mineral wool batt insulation firmly packed into opening as a permanent form. Packing material to be recessed from top surface of floor or from both surfaces of wall to accommodate the required thickness of fill material.
B. Fill, Void or Cavity Material* - Sealant — Min 1/4 in. (6 mm) thickness of fill material applied within the annulus, flush with top surface of floor or with both surfaces of wall. For 3 Hr rated assemblies, a min 1/4 in. (6 mm) diam bead of fill material shall be applied at the concrete/pipe interface at the point contact location on the top surface of floor and on both surfaces of wall.
HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CFS-S SIL GG, CFS-S SIL SL, FS-ONE Sealant, FS-ONE MAX Intumescent Sealant or CP604 Self-Leveling Firestop Sealant. CP604 and CFS-S SIL SL shall be used in floor applications only.
When CP604, CFS-S SIL GG or CFS-S SIL SL (floors only) is used, F Rating is 2 Hr.
* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively.
2 4B 1
4A3
4B
ANSI/UL1479 (ASTM E814) CAN/ULC S115
F Ratings — 2 or 3 Hr F Ratings — 2 or 3 Hr
T Rating — 0 Hr FT Rating — 0 Hr
L Rating at Ambient — Less Than 1 CFM/sq ft FH Ratings — 2 or 3 Hr
L Rating at 400 F — Less Than 1 CFM/sq ft FTH Rating — 0 Hr
L Rating at Ambient — Less Than 1 CFM/sq ft
L Rating at 400 F — Less Than 1 CFM/sq ft
System No. W-L-5029
SECTION A-A
A
A
4 3
Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc.
March 19, 2015Hilti Firestop Systems
C
CL
ASS IF IED
Classified by Underwriters Laboratories, Inc.
to UL 1479 and CAN/ULC-S115
US
ANSI/UL1479 (ASTM E814) CAN/ULC S115
F Ratings — 1, 2 and 3 Hr (See Items 1, 3 and 4)
F Ratings — 1, 2 and 3 Hr (See Items 1, 3 and 4)
T Ratings — 0, 1/2, 1 and 1-1/4 Hr (See Item 3)
FT Ratings — 0, 1/2, 1 and 1-1/4 Hr (See Item 3)
L Rating At Ambient — 4 CFM/Sq Ft FH Ratings — 1, 2 and 3 Hr (See Items 1, 2 and 4)
L Rating At 400 F — Less Than 1 CFM/Sq Ft
FTH
Ratings — 0, 1/2, 1 and 1-1/4 Hr (See
Item 3)
L Rating At Ambient — 4 CFM/Sq Ft
L Rating At 400 F — Less Than 1 CFM/Sq Ft
1. Wall Assembly — The 1, 2 or 3 hr fire-rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300, U400, V400 or W400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features:
A. Studs — Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in.
(51 by 102 mm) lumber spaced 16 in. (406 mm) OC. Steel studs to be min 2-1/2 in. (64 mm) wide for 1 and 2 hr F and FH rating and 3-1/2 in.
(89 mm) wide for 3 hr F and FH rating and spaced max 24 in. (610 mm) OC.
B. Gypsum Board* — Min 5/8 in. (16 mm) thick with square or tapered edges. The gypsum board type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual Wall and Partition Design. Max diam of opening is 18-5/8 in. (473 mm).
The hourly F and FH Ratings of the firestop system are equal to the hourly fire rating of the wall assembly in which it is installed.
2. Through Penetrants — One metallic pipe or tubing to be installed within the firestop system. Pipe or tubing to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes or tubing may be used:
A. Steel Pipe — Nom 12 in. (305 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe.
B. Iron Pipe — Nom 12 in. (305 mm) diam (or smaller) cast or ductile iron pipe.
C. Copper Tubing — Nom 6 in. (152 mm) diam (or smaller) Type L (or heavier) copper tubing. When the hourly F or FH Rating of the firestop system is 3 hr, the nom diam of copper tube shall not exceed 4 in. (102 mm).
D. Copper Pipe — Nom 6 in. (152 mm) diam (or smaller) Regular (or heavier) copper pipe. When the hourly F or FH Rating of the firestop system is 3 hr, the nom diam of copper pipe shall not exceed 4 in. (102 mm).
3. Pipe Covering* — Nom 1, 1-1/2 or 2 in. (25, 38 or 51 mm) thick hollow cylindrical heavy density (min 3.5 pcf or 56 kg/m³) glass fiber units jacketed on the outside with an all service jacket. Longitudinal joints sealed with metal fasteners or factory-applied self-sealing lap tape.
Transverse joints secured with metal fasteners or with butt tape supplied with the product. For 1 and 2 hr F and FH Ratings, the annular space between insulated penetrant and periphery of opening shall be min 0 in. (point contact) to max 1-7/8 in. (48 mm). For 3 hr F and FH Ratings, the annular space shall be min 0 in. (point contact) to max 1-1/4 in. (32 mm).
See Pipe and Equipment Covering — Materials (BRGU) category in the Building Material Directory for the names of manufacturers. Any pipe covering material meeting the above specifications and bearing the UL Classification Marking with a Flame Spread Index of 25 or less and a Smoke Developed Index of 50 or less may be used.
The hourly T, FT, FTH Ratings of the firestop system are 1/2 hr for 1 hr rated walls and 1 hr for 2 hr rated walls. For 3 hr rated walls, the hourly T, FT and FTH Ratings when steel and iron pipes are used are 1 hr. For 3 hr rated walls, the hourly T, FT and FTH Ratings when copper penetrants are used are 1-1/4 hr for 2 in. (51 mm) thick pipe covering and 0 hr for pipe covering thickness less than 2 in. (51 mm).
3A. Pipe Covering* — (Not Shown) — As an alternate to Item 3, max 2 in. (51 mm) thick cylindrical calcium silicate (min 14 pcf) units sized to the outside diam of the pipe or tube may be used. Pipe insulation secured with stainless steel bands or min 18 AWG stainless steel wire spaced max 12 in. (305 mm) OC. When the alternate pipe covering is used, the T and FT Rating shall be as specified in item 3 above.
See Pipe and Equipment Covering — Materials (BRGU) category in the Building Materials Directory for names of manufacturers. Any pipe covering material meeting the above specifications and bearing the UL Classification Marking with a Flame Spread Index of 25 or less and a Smoke Developed Index of 50 or less may be used.
4. Fill, Void or Cavity Material* — Sealant — For 1 and 2 hr F and FH Rating, min 5/8 in. (16 mm) thickness of fill material applied within the annulus, flush with both surfaces of wall. For 3 hr F and FH Rating, min 1 in. (25 mm) thickness of fill material applied within the annulus, flush with both surfaces of wall. At the point contact location between pipe covering and gypsum board, a min 1/2 in. (13 mm) diam bead of fill material shall be applied at the pipe covering/gypsum board interface on both surfaces of wall.
HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-One Sealant or FS-ONE MAX Intumescent Sealant
* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively.
A
PL001N.T.S.
FIRESTOP FOR METAL PIPE OR CONDUIT
C
PL001N.T.S.
FIRESTOP FOR METAL PIPE
D
PL001N.T.S.
FIRESTOP FOR METAL PIPE
System No. F-A-5017
SECTION A-A
F Rating ñ 2 Hr T Ratings ñ 3/4 and 1 Hr (See Item 3)
AA
Nom Pipe Diam, in. (mm) Nom Pipe Covering Thickness, in. (mm) Firestop Device T Rating, Hr
1/2 (13) 1 (25)
CP 680-75/2.5"N, CP 682-75/2.5"
3/4
CP 680-M 2", CP 680-P 2"
1 (25) 1 (25) CP 680-M 3", CP 680-P 3" 3/4
1 (25) (See Item 5) 1-1/2 (38)
CP 682-110/4"
3/4
CP 680-M 4", CP 680-P 4"
2 (51) 1 (25)
CP 680-110/4"N, CP 682-110/4"
CP 680-M 4", CP 680-P 4"
2 (51) 2 (51)
CP 680-160/6"N
3/4
CP 680-P 6"
4 (102) 1 (25)
CP 680-160/6"N
3/4
CP 680-P 6"
C
CL
ASS IF IED
Classified by Underwriters Laboratories, Inc.
to UL 1479 and CAN/ULC-S115
US
Hilti Firestop Systems
4. Pipe Covering* — Nom 1, 1-1/2 and 2 in. (25, 38 and 51 mm) thick hollow cylindrical heavy density (min 3.5 pcf or 56 kg/m3) glass fiber units, jacketed on the outside with an all service jacket.
Longitudinal joints sealed with metal fasteners or factory-applied SSL tape. Transverse joints secured with metal fasteners or with butt tape supplied with the product.
See Pipe and Equipment Covering-Materials (BRGU) category in the Building Materials Directory for names of manufacturers. Any pipe covering material meeting the above specifications and bearing the UL Classification Marking with a Flame Spread Index of 25 or less and a Smoke Developed Index of 50 or less may be used.
5. Packing Material — When using a 1 in. (25 mm) diam pipe with 1-1/2 in. (38 mm) thick glass fiber pipe insulation in a 4 in. (102 mm) device, a min 2 in. (51 mm) thickness of min 4 pcf (64 kg/m3) mineral wool batt insulation shall be firmly packed into top of device, flush with the top of the device.
*Bearing the UL Classification Mark
Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc.
December 14, 2006
1. Floor Assembly — Min 2-1/2 in. (38 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) concrete.
1A. Floor Assembly - (Optional - Not Shown) — The fire rated unprotected concrete and steel floor assembly shall be constructed of the materials and in the manner specified in the individual D900 Series Designs in the Fire Resistance Directory and as summarized below:
A. Concrete — Min 2-1/2 in. (38 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) concrete.
B. Steel Floor and Form Units* — Composite or non-composite max 3 in. (76 mm) deep galv steel fluted units as specified in the individual Floor-Ceiling Design.
2. Firestop Device* — Cast in place firestop device permanently embedded during concrete placement or grouted in concrete floor assembly in accordance with accompanying installation instructions with a max 2 in. (51 mm) projection above the top surface of the concrete.
HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI
INC — CP 680-75/2.5"N, CP 680-110/4"N, CP 680-160/6"N, CP 682-75/2.5", CP 682-110/4", CP 680-M 2", CP 680-M 3", CP 680-M 4", CP 680-P 2", CP 680-P 3", CP 680-P 4", CP 680-P 6"
3. Through Penetrants — One metallic pipe or tubing to be installed within the firestop device. Pipe or tubing to be rigidly supported on both sides of floor assembly. The following types of pipe or tubing may be used:
A. Steel Pipe — Nom 4 in. (102 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe.
B. Copper Tubing — Nom 4 in. (102 mm) diam (or smaller) Type L (or heavier) copper tubing.
C. Copper Pipe — Nom 4 in. (102 mm) diam (or smaller) Regular (or heavier) copper pipe.
The firestop device, metallic penetrant and pipe covering shall be sized as follows:
B
PL001N.T.S.
FIRESTOP FOR METAL PIPE
GENERAL PLUMBING SYMBOLS
LIMIT OF DEMOLITION
ANCHOR
REDUCER OR INCREASER
DIRECTION OF FLOW
SIDE CONNECTION
ECCENTRIC REDUCER
BOTTOM CONNECTION, 45° OR 90°
TOP CONNECTION, 45° OR 90°
DIRECTION OF PIPE PITCH (DOWN)
UNION
RISE OR DROP IN PIPE
CAPPED OUTLET
AND EXISTING WORK
POINT OF CONNECTION BETWEEN NEW
PRESSURE GAGE
THERMOMETER W/WELL
STRAINER
FLOW ELEMENTFE
PIPE UP
PIPE DOWN
CO CLEAN OUT (FLOOR/ WALL)
HOSE BIB
PLUMBING VALVE SYMBOLS
BALL VALVE (PER SPECIFICATIONS)
VALVE WITH 3/4 " HOSE ADAPTER
CHECK VALVE
ANGLE GLOBE VALVE
BUTTERFLY VALVE
MODULATING CONTROL VALVE
TWO POSITION CONTROL VALVE
THREE-WAY MODULATING CONTROL VALVE
AUTOMATIC FLOW CONTROL VALVE
PRESSURE RELIEF VALVE
VALVE (PER SPECIFICATIONS)
MANUAL AIR VENT
TEST PLUG (PRESSURE/TEMPERATURE)
GLOBE VALVE
PRESSURE REGULATING VALVE
THREE-WAY TWO POSITION CONTROL VALVE
AUTOMATIC AIR VENTAV
TRAP PRIMER VALVE/ DISTRIBUTION BOX
CO
DRAWING SYMBOLS
PL105
26-P-3
DETAIL NUMBER
DRAWING SHEET NUMBER WHERE SHOWN
SECTION LETTER
TYPICAL UNIT NO.
BUILDING NO. WHERE EQUIPMENT IS LOCATED.
PUMP NO.3 IN BUILDING NO.26
EQUIPMENT ABBREVIATION (PUMP)
DRAWING SHEET NUMBER WHERE DRAWN
FLOOR DRAIN
ROOF DRAIN
ABBREVIATIONS
A/E
AFF
AG
AP
ASRHAE
ASME
ASPE
ASSE
BFP
BSP
BTU
BTUH
C
CGA
CI
COR
CV
DCW
DHW
DHWR
DOE
DWG
DWV
EL
EPA
ET
EX
F
FD
FM
FP
FS
GAL
GPM
HB
HD
HP
HS
HYD
INV
IPC
KW
KWHR
LAV
LBS/HR
M
MAV
MBH
MER
NC
NIC
NO
NOM.
NTS
OC
OD
PDI
PG
PPM
PRV
PSI
PSIA
PSIG
RPBP
SAN
SMACNA
SF
SS
TCV
TEMP
TMV
TP
TYP
UPC
V
VS
VTR
W
WG
WHA
WM
ARCHITECT/ ENGINEER
ABOVE FINISH FLOOR
AIR GAP
ACCESS PANEL
AMERICAN SOCIETY OF REFRIGERATION, HEATING, AIR CONDITIONING ENGINEERS
AMERICAN SOCIETY OF MECHANICAL ENGINEERS
AMERICAN SOCIETY OF PLUMBING ENGINEERS
BACKFLOW PREVENTER
BLACK STEEL PIPE
BRITISH THERMAL UNIT
CELSIUS
COMPRESSED GAS ASSOCIATION
CAST IRON
CONTRACTING OFFICER'S REPRESENTATIVE (VA)
CONTROL VALVE
DOMESTIC COLD WATER
DOMESTIC HOT WATER
DOMESTIC HOT WATER RETURN
DEPARTMENT OF ENERGY
DRAWING
DRAIN, WASTE, VENT
ELEVATION
ENVIRONMENTAL PROTECTION AGENCY
EXPANSION TANK
EXISTING
FAHRENHEIT
FLOOR DRAIN
FLOW METER
FIRE PROTECTION
FLOW SWITCH
GALLON
GALLONS PER MINUTE
HOSE BIBB
HUB DRAIN
HORSEPOWER
HAND SINK
HYDRANT
INVERT
INTERNATIONAL PLUMBING CODE
KILOWATT
KILOWATT-HOUR
LAVATORY
POUNDS PER HOUR
METER
MANUAL AIR VENT
1000 BTU
MECHANICAL EQUIPMENT ROOM
NORMALLY CLOSED
NOT IN CONTRACT
NORMALLY OPEN
NOMINAL
NOT TO SCALE
ON CENTER
OUTSIDE DIAMETER
PLUMBING AND DRAINAGE INSTITUTE
PRESSURE GAUGE
PARTS PER MILLION
PRESSURE REDUCING VALVE
POUNDS PER SQUARE INCH
POUNDS PER SQUARE INCH ATMOSPHERE
POUNDS PER SQUARE INCH GAUGE
REDUCED PRESSURE BACKFLOW PREVENTER
SANITARY
SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION
SQUARE FEET
STAINLESS STEEL
TEMPERATURE CONTROL VALVE
TEMPERATURE
THERMAL MIXING VALVE
TRAP PRIMER
TYPICAL
UNIFORM PLUMBING CODE
VENT
VENT STACK
VENT THROUGH ROOF
WASTE
WATER GAUGE
WATER HAMMER ARRESTER
WATER METER
PLAN NOTE
CW
HW
HWR
HPCW
HPHW
HPHWR
WATER LINE REMOVED
DOMESTIC COLD WATER, COLD WATER
DOMESTIC HOT WATER, HOT WATER
DOMESTIC HOT WATER RETURN, HOT WATER RETURN
HIGH PRESSURE COLD WATER
HIGH PRESSURE HOT WATER
HIGH PRESSURE HOT WATER RETURN
REMOTE SENSOR CABLING (18-2 TWISTED PAIR) AND
CONDUIT. PROVIDE JUNCTION BOXES (NOT SHOWN)
AS REQUIRED BY NFPA 70-2014
DATA CABLING IN CONDUIT
LINE TYPES
TEMPERATURE SENSOR W/WELL
BALANCING VALVE
8P/3/4"C
TYPICAL SENSOR WIRING RACEWAY
NUMBER PAIRS OF CABLING.
CONDUIT SIZE.
WORK DELETED BY ALTERNATE
INDICATES ALTERNATE NUMBER
H1 A
CONSTRUCTION PHASING GENERAL NOTES (TYPICAL ALL SHEETS):
A. THE FACILITY SHALL REMAIN IN FULL OPERATION DURING NORMAL BUSINESS HOURS AND WILL NOT HAVE ANY OUTAGES OR DISRUPTIONS
THAT WILL REDUCE, OR PREVENT, THE USE OF THE FACILITY FOR EMPLOYEES AND PATIENTS - IN PART OR WHOLE. (WEEKDAYS 7AM-5PM
AND WEEKENDS/HOLIDAYS 8AM-6PM)
B. NIGHT AND WEEKEND WORK SHALL BE THE STANDARD CONSTRUCTION WORKING TIMES FOR DEMOLITIONS AND INSTALLATIONS THAT IMPACT UTILITIES AND AREAS SERVING PATIENTS. REFER TO GENERAL NOTE H FOR WORKING TIME RESTRICTIONS.
C. SOME INSTALLATIONS MAY OCCUR DURING WEEK DAY TIMES DEPENDING ON LOCATION AND HAVING NO IMPACT TO THE FACILITY
SERVING PATIENTS. REFER TO GENERAL NOTE H FOR WORKING TIME RESTRICTIONS.
D. COORDINATION WITH THE COR FOR TIMES, LOCATIONS, OUTAGES, AND OTHER CONSTRUCTION SCHEDULING SHALL TAKE PLACE 14 DAYS
MINIMUM BEFORE ACTUAL WORK TAKES PLACE.
E. ALL CEILINGS ARE LAY-IN TILE CEILING EXCEPT WHERE NOTED OTHERWISE.
F. PROVIDE HILTI SYSTEMS FIRE-STOPPING ASSEMBLIES AT ALL PENETRATIONS OF RATED WALLS, FLOORS, CEILINGS, AND OTHER
STRUCTURES. SEE SPECIFICATIONS FOR MORE DETAILS.
G. PROVIDE CONCRETE PADS WITH 4X4XW2.9/W2.8 WWR (MIDDLE OF PAD HEIGHT), AND "PIN" NEW CONCRETE INTO EXISTING CONCRETE.
PROVIDE STRUCTURAL EPOXY BONDING AGENT (SIKADUR 32 BY SIKA CORP OR APPROVED EQUAL) BETWEEN EXISTING CONCRETE AND NEW CONCRETE. PAD SHALL EXTEND 4" BEYOND EQUIPMENT ON ALL SIDES. SEE DETAIL C/PL-501.
H. CONSTRUCTION WORKING TIME SCHEDULE (PER APPROVAL BY COR):
I. WEEKDAYS:
AFTER 5PM.
AFTER 8PM IF ISOLATING ENTIRE DCW SYSTEM.
WEEKENDS/HOLIDAYS:
AFTER 6PM FOR DCW ISOLATION.
ANYTIME IF WORKING ON FLOORS 2-4.
ANYTIME IF WORKING IN ENGINEERING SPACES ON FLOOR 1.
ALL WORK SHALL BE COMPLETED AND ALL SYSTEMS SHALL BE RETURNED TO NORMAL OPERATION NO LATER THAN 6AM. ALL WORK AREAS SHALL BE CLEANED AND FREE OF ALL DEBRIS, CONSTRUCTION MATERIALS AND EQUIPMENT.
FULLY SPRINKLERED
Collaborative Design, Ltd.
2727 Tuller Parkway, Suite 200 Dublin, Ohio 43017 Tel 614.798.1515 mmonks engineers
3073 North High Street Columbus, Ohio 43202 Phone (614) 267-4928
Fax (614) 267-5617 wemonks@wemonks.com
ABBREVIATIONS, SYMBOLS,
& GENERAL INFORMATION
TWM DR/JB
PL-001
SUGGESTED SEQUENCE OF CONSTRUCTION FOR NEW BOOSTER PUMP #DWP-1:
1. DAY 1: REVIEW SITE AND PREPARE LAYOUT OF PIPING; COORDINATE TEE AND VALVE INSERTS WITH NEW PIPING ARRANGEMENT FOR OUTAGE
INSTALLATIONS.
2. DCW SYSTEM OUTAGE (WEEKEND WORK FROM 6PM TO 6AM): COORDINATE AND SCHEDULE DCW OUTAGE WITH THE COR AND VAACC FACILITY PERSONNEL. PROVIDE ALL INSERTS (TEES, VALVES, ETC.) PER OUTAGE DRAWING IN ANTICIPATION OF FUTURE PIPING CONNECTIONS AND
DEMOLITION OF EXTRANEOUS PIPING.
3. NEW DWP-1 INSTALL: PREPARE EXISTING FLOORING AND POUR HOUSEKEEPING PAD FOR NEW DWP-1 AND EXPANSION TANK; PLACE NEW DWP-1
AND EXPANSION TANK ON PAD AND SECURE IN PLACE WITH PROPER VIBRATION ISOLATION.
4. NEW DWP-1 CONNECTIONS (AFTER DCW OUTAGE): MAKE PIPING CONNECTIONS TO NEW DWP-1 AND EXPANSION TANK. MAKE CONTROL AND MONITORING WIRING CONNECTIONS TO DHWP-1 PANEL AND EXTEND TO FACILITY CONTROLS PANEL; CONFIRM STATUS OF WIRING CONNECTIONS.
5. WATER ACTIVATION: WHEN ALL PIPING CONNECTIONS ARE IN PLACE, TESTED, SANITIZED, AND FLUSHED, ACTIVATE DCW FLOW THROUGH NEW DWP-1 IN PREPARATION FOR SETTING PUMP SYSTEM INTO OPERATION. NOTE: DO NOT ALLOW WATER IN NEW PUMP SYSTEM TO STAGNATE.
6. ELECTRICAL WORK: COORDINATE AND SCHEDULE ELECTRIC POWER OUTAGE FOR SWITCHING THE ELECTRIC POWER FEED FROM THE EXISTING DWP-1 TO THE NEW DWP-1 PUMP PACKAGE. PRE-FABRICATE AS MUCH CONDUIT, WIRING, ETC. AS POSSIBLE IN PREPARATION FOR ELECTRICAL
OUTAGE.
7. PRE-START-UP AND PFC CONFIRMATION: REVIEW ALL PRE-FUNCTIONAL CHECKLIST ITEMS (COMMISSIONING) AND PRE-START-UP PROCEDURES AND PROTOCOLS (MANUFACTURER'S) FOR THE NEW BOOSTER PUMP #DWP-1 WITH ALL REQUIRED TECHNICIANS, TRADESMAN, FACILITY PERSONNEL, ETC. FOR COMPLETENESS AND READINESS FOR START-UP AND ACTIVATION INTO THE SYSTEM.
8. ELECTRICAL OUTAGE - POWER CONNECTION AND START-UP (WEEKEND WORK FROM 6PM-6AM):
a. PERFORM SWITCH-OVER OF ELECTRICAL POWER FEED FROM EXISTING DWP-1 TO NEW DWP-1. MAKE ALL OTHER SWITCH-OVERS FROM
EXISTING DWP-1 TO NEW DWP-1, SUCH AS CONTROLS, PIPING FLOW, ETC.
b. PERFORM START-UP OF NEW EQUIPMENT PER MANUFACTURER'S INSTRUCTIONS AND CONTRACT DOCUMENTS.
c. INITIATE INTO DCW SYSTEM: WHEN NEW EQUIPMENT PROVES TO BE FULLY FUNCTIONAL, ACTIVATE DCW INTO AND OUT OF NEW BOOSTER
PUMP SYSTEM FOR FULL OPERATION AND SERVICE TO THE BUILDING.
d. DE-ACTIVATE EXISTING DWP-1: AFTER NEW DWP-1 PROVES TO BE FULLY OPERATIONAL AND FUNCTIONAL, SHUT-OFF WATER VALVES, ETC.
SERVING THE OLD EXISTING DWP-1 IN PREPARATION OF DEMOLITION AND REMOVAL.
e. COMMISSIONING: FOLLOW WITH FPT DOCUMENTATION OF NEW EQUIPMENT AND DEVICES PER CONTRACT DOCUMENTS.
9. DEMOLITION AND REMOVAL: AFTER NEW BOOSTER PUMP PACKAGE HAS SUCCESSFULLY PERFORMED FOR A WEEK AND WITH THE COR'S
APPROVAL, BEGIN DEMOLITION AND REMOVAL OF THE ABANDONED PUMP PACKAGE - COMPLETE.
CONTRACTOR IS RESPONSIBLE FOR SEQUENCING CONSTRUCTION TO
COMPLETE ALL WORK TO MEET STATED DEADLINES WITH MINIMAL
DISRUPTION TO NORMAL BUILDING ACTIVITIES. THE SUGGESTED
SEQUENCE BELOW IS NOT ALL-INCLUSIVE AND IS INTENDED AS A GUIDE TO
ASSIST THE CONTRACTOR IN PLANNING THE WORK TO MEET THE PROJECT
MILESTONES.
AMERICAN SOCIETY OF SANITARY ENGINEERS
BRITISH THERMAL UNIT (PER) HOUR
GENERAL ELECTRICAL SYMBOLS
POWER CONDUIT RUN EXPOSED
CONDUIT CONCEALED IN CEILING OR WALL. ARROWS
INDICATE HOME RUN TO PANELBOARD. LETTERS AND
NUMBERS INDICATE PANELBOARD AND CIRCUIT NUMBER.
GROUND FAULT INTERRUPTER RECEPTICLE
CIRCUIT SETTER
PANELBOARD, TOP AT 72" (120/208V.,3Ø,4W)
PANELBOARD, (480/277V.,3Ø,4W)
DISINFECTION OF PIPING: ALL PIPE AND FITTINGS INSTALLED UNDER THIS
CONTRACT MUST BE SPRAY-CHLORINATED BEFORE INSTALLATION IN
ACCORDANCE WITH AWWA C651-05. SEE SPECIFICATION SECTION 22 11 00
"FACILITY WATER DISTRIBUTION", PARAGRAPH 3.3. REFERENCE THE PROJECT'S
ICRA FOR ADDITIONAL DISINFECTION AND TESTING REQUIREMENTS.
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text Approved: Project Director
AutoCAD SHX Text Project Title
AutoCAD SHX Text Date
AutoCAD SHX Text Location
AutoCAD SHX Text Checked
AutoCAD SHX Text Building Number
AutoCAD SHX Text Project Number
AutoCAD SHX Text Drawing Number
AutoCAD SHX Text Drawn
AutoCAD SHX Text Dwg. of
AutoCAD SHX Text Revisions:
AutoCAD SHX Text Date
AutoCAD SHX Text
CONSULTANTS:
AutoCAD SHX Text
ARCHITECT/ENGINEERS:
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ADD DOMESTIC WATER PRESSURE BOOSTER
AutoCAD SHX Text 420 North James Rd. Columbus, Ohio 43219
AutoCAD SHX Text 12/18/2017
AutoCAD SHX Text 757-19-203
AutoCAD SHX Text
AutoCAD SHX Text a
AutoCAD SHX Text Tec
AutoCAD SHX Text Inc.
AutoCAD SHX Text Company
AutoCAD SHX Text 1A
AutoCAD SHX Text
FARID MEHR, PE CHIEF, ENGINEERING SERVICE
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text D
AutoCAD SHX Text 050975
AutoCAD SHX Text
MILLER
AutoCAD SHX Text W.
AutoCAD SHX Text
TODD
AutoCAD SHX Text H
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text P
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text E
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text F
AutoCAD SHX Text
BID CONSTRUCTION SET - REVISED
AutoCAD SHX Text 1/11/18
AutoCAD SHX Text
BID CONSTRUCTION SET - REVISED
AutoCAD SHX Text 3/30/18
AutoCAD SHX Text
AD1
1A
1A350
1A008 1A008
1A228
1A226
1A231
1A229
1A2271A224
1A218
1A222
1A225
1A223
1A210
1A214
1A221
1A219
1A217 1A2151A213
1A212
1A230
CL-03
CL-02
CL-01
CL-04
CL-05
C1E2
C1DEA
C1E2
CW
HWHWR
HPCW
H W
R
C W
H W
H W
R
HWR
CW
HW
CW
HW
D H
W
D
H W
R H
PC
W
H W
R
HWR
HW
CW
H W
R H
W C
W
H W
C W
1P/1/2"C
5P/3/4"C
2P/1/2"C
7P/3/4"C
4P/3/4"C
FULLY SPRINKLERED
Collaborative Design, Ltd.
2727 Tuller Parkway, Suite 200 Dublin, Ohio 43017 Tel 614.798.1515 mmonks engineers
3073 North High Street Columbus, Ohio 43202 Phone (614) 267-4928
Fax (614) 267-5617 wemonks@wemonks.com
K
K
L
L
M
M
N
N
O
O
P
P
Q
Q
R
R
S
S
T
T
7.37.3
T.2
T.2
4.3
4.3
4.9
4.9
6.2
6.2
9.2
9.2
3/32"=1'-0"
FIRST FLOOR PLUMBING PLAN - WEST
NORTH
FIRST FLOOR PLUMBING
PLAN - WEST
TWM DR/JB
PL-111
PLAN NOTES:
COORDINATE LOCATIONS WITH EXISTING CONDITIONS
AND COR.
PROVIDE CHLORINE ANALYZER ASSEMBLIES FOR DHW
(120ºF) AND DHWR SYSTEMS. PLACE ASSEMBLIES BACK
TO BACK ON SAME SUPPORTS. COORDINATE EXACT
LOCATION WITH COR. SEE DETAIL B/PL-503 FOR MORE
INFORMATION.
ADD EXTENDERS, DEVICES, ETC. TO EXISTING WATER
MONITORING ASSEMBLY TO ACCOMODATE NEW
CHLORINE ANALYZERS' WIRE TERMINATIONS. MAKE ALL
FINAL CONNECTIONS. SEE DETAIL C/PL-503 FOR MORE
INFORMATION.
SEE DETAILS ON SHEET PL-501 FOR MORE INFORMATION
FOR THE NEW BOOSTER PUMP #DWP-1 REPLACEMENT
WORK, NEW CHLORINE ANALYZERS, HYPERCHLORINATION
INJECTION POINTS, AND DEMOLITION OF EXISTING DWP-1.
LOCATION FOR NEW BOOSTER PUMP #DWP-1 AND
EXPANSION TANK. COORDINATE WITH COR.
EXISTING DWP-1 AND EXPANSION TANK.
EXISTING WATER METER, BYPASS AND RPBP.
EXISTING DOMESTIC WATER HEATERS.
PROVIDE 1/2" SAMPLING LINES TO CHLORINE ANALYZERS
FROM EXISTING DHW SUPPLY (120ºF) AND DHWR PIPING
SYSTEMS.
SEE SHEET PL-112 FOR CONTINUATION.
PROVIDE NEW 20A, 120V CIRCUIT, (2) #12 & (1) #12 GRD IN
3/4"C FROM 'SPARE' BREAKER #9 IN EXISTING PANEL C1E2
TO NEW CHLORINE ANALYZERS.
PROVIDE REMOTE SENSOR WIRING CONDUIT FROM
FOURTH, THIRD AND SECOND FLOORS. SEE SHEET PL-141
FOR CONTINUATION IN ROOM 4A011, AND SHEET PL-121
FOR CONTINUATION IN ROOM 2A017.
(1) #18 TWISTED PAIR SHIELDED WIRE IN 1/2"C FROM
CHLORINE ANALYZER IN ROOM 1B103A TO WATER
QUALITY MONITOR IN ROOM 1A350.
(4) #18 TWISTED PAIR SHIELDED WIRE IN 3/4"C FROM
CHLORINE ANALYZERS IN ROOMS 3B001 AND 4A011 TO
WATER QUALITY MONITOR IN ROOM 1A350.
(5) #18 TWISTED PAIR SHIELDED WIRE IN 3/4"C FROM
CHLORINE ANALYZERS IN ROOMS 1B103A, 3B001, AND
4A001 TO WATER QUALITY MONITOR IN ROOM 1A350.
(2) #18 TWISTED PAIR SHIELDED WIRE IN 3/4"C FROM
CHLORINE ANALYZERS IN ROOM 1A350 TO WATER
QUALITY MONITOR IN ROOM 1A350.
(7) #18 TWISTED PAIR SHIELDED WIRE IN 3/4"C FROM
CHLORINE ANALYZERS IN ROOMS 1A350, 1B103A, 3B001,
AND 4A001 TO WATER QUALITY MONITOR IN ROOM 1A350.
PROVIDE NEW 20A, 120V GFCI DUPLEX RECEPTACLE AND
WIRE COMPLETE. RECEPTACLE TO BE DEDICATED FOR
EXPANSION TANK SOLENOID VALVE.
GENERAL NOTES:
a. COORDINATE STAGING AREAS WITH THE COR.
b. PROVIDE BRANCH ISOLATION VALVE ON PIPING THAT IS LACKING
BRANCH VALVE DURING MAJOR OUTAGES OF MULTIPLE BRANCHES.
c. COORDINATE ALL WORK WITH AND COMPLY WITH INFECTIOUS DISEASE
PREVENTION REQUIREMENTS AS STATED IN SPECIFICATION #01 35 26.
d. PIPE SIZING IS FOR BIDDING PURPOSES ONLY. CONTRACTOR SHALL
FIELD VERIFY EXACT PIPING SIZING AND CONFIGURATIONS, AND WILL
NOTIFY THE COR OF ANY DISCREPANCIES BEFORE CONTINUING WITH
THE WORK.
e. CONDUIT ROUTING IS APPROXIMATE AND MUST BE COORDINATED WITH
EXISTING CONDITIONS. MAKE ADJUSTMENTS TO LOCATIONS AS
REQUIRED FOR PROPER ACCESS TO NEW JUNCTION BOXES AND TO ANY
EXISTING ITEMS REQUIRING ACCESS.
f. CONTRACTOR SHALL REMOVE EXISTING LAY-IN CEILING TILES WHERE
REQUIRED TO GAIN ACCESS FOR DEMOLITION AND NEW WORK.
PROTECT TILES AND RE-INSTALL AT END OF WORK DAY. REPLACE ANY
TILES DAMAGED DURING CONSTRUCTION.
g. SEE ENLARGED FLOOR PLAN E/1A-PL-501 FOR MORE DETAILS.
KEY PLAN
PLAN
NORTH
HYPERCHLORINATION EQUIPMENT NOTES:
PROVIDE HYPERCHLORINATION INJECTION SPOOL PIECE
PER DETAIL A1/PL-501 IN EXISITING 6" DCW MAIN SERVICE
PIPING.
PROVIDE HYPERCHLORINATION INJECTION SPOOL PIECE
PER DETAIL A1/PL-501 IN EXISITING 1-1/2" DHW PIPING.
PROVIDE HYPERCHLORINATION INJECTION SPOOL PIECE
PER DETAIL A1/PL-501 IN EXISITING 2-1/2" DCW PIPING.
PROVIDE HYPERCHLORINATION INJECTION SPOOL PIECE
PER DETAIL A1/PL-501 IN EXISITING 2" DHW PIPING.
PROVIDE HYPERCHLORINATION INJECTION SPOOL PIECE
PER DETAIL A1/PL-501 IN EXISITING 2-1/2" DCW PIPING.
CL-01
CL-02
CL-03
CL-04
CL-05
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text Approved: Project Director
AutoCAD SHX Text Project Title
AutoCAD SHX Text Date
AutoCAD SHX Text Location
AutoCAD SHX Text Checked
AutoCAD SHX Text Building Number
AutoCAD SHX Text Project Number
AutoCAD SHX Text Drawing Number
AutoCAD SHX Text Drawn
AutoCAD SHX Text Dwg. of
AutoCAD SHX Text Revisions:
AutoCAD SHX Text Date
AutoCAD SHX Text
CONSULTANTS:
AutoCAD SHX Text
ARCHITECT/ENGINEERS:
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ADD DOMESTIC WATER PRESSURE BOOSTER
AutoCAD SHX Text 420 North James Rd. Columbus, Ohio 43219
AutoCAD SHX Text 12/18/2017
AutoCAD SHX Text 757-19-203
AutoCAD SHX Text
AutoCAD SHX Text a
AutoCAD SHX Text Tec
AutoCAD SHX Text Inc.
AutoCAD SHX Text Company
AutoCAD SHX Text 1A
AutoCAD SHX Text
FARID MEHR, PE CHIEF, ENGINEERING SERVICE
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text D
AutoCAD SHX Text 050975
AutoCAD SHX Text
MILLER
AutoCAD SHX Text W.
AutoCAD SHX Text
TODD
AutoCAD SHX Text H
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text P
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text E
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text F
AutoCAD SHX Text
BID CONSTRUCTION SET - REVISED
AutoCAD SHX Text 1/11/18
AutoCAD SHX Text
BID CONSTRUCTION SET - REVISED
3/30/18
1B100B
1B101
1B100 1B011
1B090
1B092 1B094
1B039
1B072
1B072A
1B076
1B075
1B074
1B096 1B097
1B095
1B093
1B091
1B098
1B100A
1B111
1B116
1B115
1B117
1B118
1B119
1B107
1B105
1B012
1B113
1B0091B005
1B250A1B250B1B250C
1B252
1B250D
1B251A
1B006
1B264
1B253
1B265 1B251B1B250E
1B262
1B254
1B258 1B259
1B250J1B250I
1B250H
1B277
1B276
1B253 1B261
1B251C
HW
1'- 4"
CW
HWHWR
CW
HW
C W
H W
HWR
HWR
HW
CW
H W
R H
W C
W
HW
HWR
CW
CW HWCW
HWR
C W
H W
R H
W C
W
CW
HW
HWR
C W
H W
H W
R
CW
F1E1
1P/1/2"C
21B103A
FULLY SPRINKLERED
Collaborative Design, Ltd.
2727 Tuller Parkway, Suite 200 Dublin, Ohio 43017 Tel 614.798.1515 mmonks engineers
3073 North High Street Columbus, Ohio 43202 Phone (614) 267-4928
Fax (614) 267-5617 wemonks@wemonks.com
3/32"=1'-0"
FIRST FLOOR PLUMBING PLAN - EAST
NORTH
A
A
B
B
C
C
D
D
E
E
F
F
G
G
H
H
J
J
7.37.3
4.9
4.9
6.2
6.2
3.83.8
PLAN NOTES:
PROVIDE CHLORINE ANALYZER ASSEMBLY FOR DCW
SYSTEM. MOUNT ON THE WEST WALL. SEE DETAIL
B/PL-503 FOR MORE INFORMATION.
PROVIDE 1/2" SAMPLING LINE TO CHLORINE ANALYZER
FROM EXISTING DCW SERVING MIXING VALVE (EAST
WALL).
SEE SHEET PL-111 FOR CONTINUATION.
PROVIDE NEW 20A, 120V CIRCUIT, (2) #12 & (1) #12 GRD IN
3/4"C FROM EXISTING PANEL F1E1 IN ROOM 1B608 TO NEW
CHLORINE ANALYZER. SEE SHEET PL-113 FOR PANEL
LOCATION.
(1) #18 TWISTED PAIR SHIELDED WIRE IN 1/2"C FROM
CHLORINE ANALYZER IN ROOM 1B103A TO WATER
QUALITY MONITOR IN ROOM 1A350. SEE SHEET PL-111.
GENERAL NOTES:
a. COORDINATE STAGING AREAS WITH THE COR.
b. PROVIDE BRANCH ISOLATION VALVE ON PIPING THAT IS LACKING BRANCH
VALVE DURING MAJOR OUTAGES OF MULTIPLE BRANCHES.
c. COORDINATE ALL WORK WITH AND COMPLY WITH INFECTIOUS DISEASE
PREVENTION REQUIREMENTS AS STATED IN SPECIFICATION #01 35 26.
d. PIPE SIZING IS FOR BIDDING PURPOSES ONLY. CONTRACTOR SHALL FIELD
VERIFY EXACT PIPING SIZING AND CONFIGURATIONS, AND WILL NOTIFY THE
COR OF ANY DISCREPANCIES BEFORE CONTINUING WITH THE WORK.
e. CONDUIT ROUTING IS APPROXIMATE AND MUST BE COORDINATED WITH
EXISTING CONDITIONS. MAKE ADJUSTMENTS TO LOCATIONS AS REQUIRED
FOR PROPER ACCESS TO NEW JUNCTION BOXES AND TO ANY EXISTING ITEMS
REQUIRING ACCESS.
f. CONTRACTOR SHALL REMOVE EXISTING LAY-IN CEILING TILES WHERE
REQUIRED TO GAIN ACCESS FOR DEMOLITION AND NEW WORK. PROTECT
TILES AND RE-INSTALL AT END OF WORK DAY. REPLACE ANY TILES DAMAGED
DURING CONSTRUCTION.
g. WORKERS SHALL BE SCREENED BEFORE ACCESSING ROOM 1B098 AND THE
MRI AREA. COORDINATE WITH THE COR.
h. WORKERS SHALL COORDINATE WITH THE COR FOR ACCESSING THE
PHARMACY AREA.
FIRST FLOOR PLUMBING
PLAN - EAST
TWM DR/JB
PL-112
KEY PLAN
PLAN
NORTH
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text Approved: Project Director
AutoCAD SHX Text Project Title
AutoCAD SHX Text Date
AutoCAD SHX Text Location
AutoCAD SHX Text Checked
AutoCAD SHX Text Building Number
AutoCAD SHX Text Project Number
AutoCAD SHX Text Drawing Number
AutoCAD SHX Text Drawn
AutoCAD SHX Text Dwg. of
AutoCAD SHX Text Revisions:
AutoCAD SHX Text Date
AutoCAD SHX Text
CONSULTANTS:
AutoCAD SHX Text
ARCHITECT/ENGINEERS:
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ADD DOMESTIC WATER PRESSURE BOOSTER
AutoCAD SHX Text 420 North James Rd. Columbus, Ohio 43219
AutoCAD SHX Text 12/18/2017
AutoCAD SHX Text 757-19-203
AutoCAD SHX Text
AutoCAD SHX Text a
AutoCAD SHX Text Tec
AutoCAD SHX Text Inc.
AutoCAD SHX Text Company
AutoCAD SHX Text 1A
AutoCAD SHX Text
FARID MEHR, PE CHIEF, ENGINEERING SERVICE
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text D
AutoCAD SHX Text 050975
AutoCAD SHX Text
MILLER
AutoCAD SHX Text W.
AutoCAD SHX Text
TODD
AutoCAD SHX Text H
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text P
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text E
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text F
AutoCAD SHX Text
BID CONSTRUCTION SET - REVISED
AutoCAD SHX Text 1/11/18
AutoCAD SHX Text
BID CONSTRUCTION SET - REVISED
1B100B
1B101
1B100 1B011
1B090
1B092 1B094
1B039
1B072
1B072A
1B076
1B075
1B074
1B096 1B097
1B095
1B093
1B091
1B098
1B100A
1B012
HW
3.8
HW
HWR
CW
CW HWCW
HWR
C W
F1E1
F1E1 1B608
1P/1/2"C
21B103A
1B631 1B632 1B633 1B634
1B624
1B622
1B620
1B618
1B616
1B614
1B612
1B603 1B604
1B605
1B641 1B640
1B625
1B626
1B609
1B621
1B617
1B613 1B610
1B602-11B600
1B635
1B636
FULLY SPRINKLERED
Collaborative Design, Ltd.
2727 Tuller Parkway, Suite 200 Dublin, Ohio 43017 Tel 614.798.1515 mmonks engineers
3073 North High Street Columbus, Ohio 43202 Phone (614) 267-4928
Fax (614) 267-5617 wemonks@wemonks.com
3/32"=1'-0"
FIRST FLOOR PLUMBING PLAN - EAST ADDITION
NORTH
FIRST FLOOR PLUMBING
PLAN - EAST ADDITION
TWM DR/JB
PL-113
KEY PLAN
PLAN
NORTH
A
A
B
B
C
C
D
D
E
E
F
F
G
G
A.3
0.1
0.5
0.8
A.5
0.2
A.1 A.2 A.8
A.8
A.2
A.1
0.1
0.8
0.5
0.2
GENERAL NOTES:
a. COORDINATE STAGING AREAS WITH THE COR.
b. PROVIDE BRANCH ISOLATION VALVE ON PIPING THAT IS LACKING BRANCH
VALVE DURING MAJOR OUTAGES OF MULTIPLE BRANCHES.
c. COORDINATE ALL WORK WITH AND COMPLY WITH INFECTIOUS DISEASE
PREVENTION REQUIREMENTS AS STATED IN SPECIFICATION #01 35 26.
d. PIPE SIZING IS FOR BIDDING PURPOSES ONLY. CONTRACTOR SHALL FIELD
VERIFY EXACT PIPING SIZING AND CONFIGURATIONS, AND WILL NOTIFY THE
COR OF ANY DISCREPANCIES BEFORE CONTINUING WITH THE WORK.
e. CONDUIT ROUTING IS APPROXIMATE AND MUST BE COORDINATED WITH
EXISTING CONDITIONS. MAKE ADJUSTMENTS TO LOCATIONS AS REQUIRED
FOR PROPER ACCESS TO NEW JUNCTION BOXES AND TO ANY EXISTING ITEMS
REQUIRING ACCESS.
f. CONTRACTOR SHALL REMOVE EXISTING LAY-IN CEILING TILES WHERE
REQUIRED TO GAIN ACCESS FOR DEMOLITION AND NEW WORK. PROTECT
TILES AND RE-INSTALL AT END OF WORK DAY. REPLACE ANY TILES DAMAGED
DURING CONSTRUCTION.
g. WORKERS SHALL BE SCREENED BEFORE ACCESSING ROOM 1B098 AND THE
MRI AREA. COORDINATE WITH THE COR.
h. WORKERS SHALL COORDINATE WITH THE COR FOR ACCESSING THE
PHARMACY AREA.
PLAN NOTES:
EXISTING PANEL F1E1 TO FEED NEW CHLORINE
ANALYZER IN ROOM 1B103A FROM EXISTING 20A 'SPARE'
BREAKER #5. SEE SHEET PL-112.
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text Approved: Project Director
AutoCAD SHX Text Project Title
AutoCAD SHX Text Date
AutoCAD SHX Text Location
AutoCAD SHX Text Checked
AutoCAD SHX Text Building Number
AutoCAD SHX Text Project Number
AutoCAD SHX Text Drawing Number
AutoCAD SHX Text Drawn
AutoCAD SHX Text Dwg. of
AutoCAD SHX Text Revisions:
AutoCAD SHX Text Date
AutoCAD SHX Text
CONSULTANTS:
AutoCAD SHX Text
ARCHITECT/ENGINEERS:
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ADD DOMESTIC WATER PRESSURE BOOSTER
AutoCAD SHX Text 420 North James Rd. Columbus, Ohio 43219
AutoCAD SHX Text 12/18/2017
AutoCAD SHX Text 757-19-203
AutoCAD SHX Text
AutoCAD SHX Text a
AutoCAD SHX Text Tec
AutoCAD SHX Text Inc.
AutoCAD SHX Text Company
AutoCAD SHX Text 1A
AutoCAD SHX Text
FARID MEHR, PE CHIEF, ENGINEERING SERVICE
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text D
AutoCAD SHX Text 050975
AutoCAD SHX Text
MILLER
AutoCAD SHX Text W.
AutoCAD SHX Text
TODD
AutoCAD SHX Text H
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text P
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text E
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text F
AutoCAD SHX Text
BID CONSTRUCTION SET - REVISED
AutoCAD SHX Text 1/11/18
AutoCAD SHX Text
BID CONSTRUCTION SET - REVISED
2A321 2A450A 2A451 2A451B
2A451A
2A450
2A454
2A428
2A4262A415
2A417
2A452
2A419
2A418
2A416
2A414 2A344
2A343
2A336
2A446
2A463A2A463
2A460
2A464
2A447
2A437
2A435
2A433
2A431 2A441
2A440 2A442
2A443
2A444
2A445 2A430
2A519 2A510
2A007
2A007
2A500
2A501
2A501B 2A504
2A009
2A008
2A011 2A013
2A
2A432
2A406
2A502
2A001
2A002
2A031
2A033
2A040
2A034 2A032
2A039
2A044 2A036
2A420
2A456
2A457 2A459
2A462
2A438 2A427
2A4362A425
2A
2A413 2A424
2A422 2A411
2A
2A412
2A414A
2A302
2A309
2A300 2A400
2A404
2A003
2A0352A0372A050 2A050
2A051
2A052
2A401
2A402
HPHWR HPHWR
H
PH
W R
H
PH
W H
PC
W
2" ø
H
PH
W R
H
PH
W
H
PH
W H
PC
W
H
PH
W H
PC
W
HPHWR
H
PH
W H
PC
W
H
PH
W H
PC
W
HPHWR
H
PH
W R
H
PH
W H
PC
W
HPHWR
H
PH
W R
HPHWR
H
PC
W H
PH
W
H
PH
W R
2A521 2A560
2A559
2A550 2A561
2A562
2A517
2A515
2A516
2A319
2A317
2A315
2A313
2A311
2A310A
2S001
2A006
2A309
2A
2A310
2A323 2A325
2A327 2A338A 2A338
2A324 2A318
2A316
2A318A
2A333
2A341
2A330
2A330
2A340
2A342 2A334
2A304 2A332
2A306
2A3312A314
2A312 2A308
2A307 2A305
2A004
2A303
2A301
2A092 2A090
2A091
2A092
2A083 2A093
2A062
2A038
2A040
2A558
2A557
2A556
2A550
2A555
2A509
2A554 2A553
2A550
2A552 2A551
2A514
2A512
2A503 2A509
2A501A
2A014
2A018
2S002
2A012
2A015
2A016
2A019
2A020
2A511
2A513
HPHW
HPCW
2A423
2A421
2A434
2A010
2A017
CL-07
CL-06
3P/1/2"C 3
FULLY SPRINKLERED
Collaborative Design, Ltd.
2727 Tuller Parkway, Suite 200 Dublin, Ohio 43017 Tel 614.798.1515 mmonks engineers
3073 North High Street Columbus, Ohio 43202 Phone (614) 267-4928
Fax (614) 267-5617 wemonks@wemonks.com
K
K
L
L
M
M
N
N
O
O
P
P
Q
Q
R
R
S
S
T
T
7.37.3
T.2
T.2
6.2
6.2
9.2
9.2
KEY PLAN
PLAN
NORTH
SECOND FLOOR PLUMBING
PLAN - NORTHWEST
TWM DR/JB
PL-121
3/32"=1'-0"
SECOND FLOOR PLUMBING PLAN - NORTHWEST
NORTH
PLAN NOTES:
PROVIDE REMOTE SENSOR WIRING CONDUIT FROM
FOURTH, THIRD AND SECOND FLOORS DOWN THROUGH
FLOOR SLEEVE. CONDUIT EXTENDED INTO ROOM 1A015
BELOW. SEE SHEET PL-131 FOR CONTINUATION ABOVE
AND SEE SHEET PL-111 FOR CONTINUATION BELOW.
HYPERCHLORINATION SPOOL PC MANIFOLD: PROVIDE
OFFSET PER DETAIL D/PL-503 PLACE SPOOL PC. IN BEST
ACCESSIBLE LOCATION ABOVE CEILING AND ROUTE BACK
TO 2" DCW PIPING.
(3) #18 TWISTED PAIR SHIELDED WIRE FROM CHLORINE
ANALYZERS IN ROOM 3B001 TO WATER QUALITY MONITOR
IN ROOM 1A350. SEE SHEET PL-111.
SEE SHEET PL-123 FOR CONTINUATION.
GENERAL NOTES:
a. COORDINATE STAGING AREAS WITH THE COR.
b. PROVIDE BRANCH ISOLATION VALVE ON PIPING THAT IS LACKING
BRANCH VALVE DURING MAJOR OUTAGES OF MULTIPLE
BRANCHES.
c. COORDINATE ALL WORK WITH AND COMPLY WITH INFECTIOUS
DISEASE PREVENTION REQUIREMENTS AS STATED IN
SPECIFICATION #01 35 26.
d. PIPE SIZING IS FOR BIDDING PURPOSES ONLY. CONTRACTOR
SHALL FIELD VERIFY EXACT PIPING SIZING AND CONFIGURATIONS,
AND WILL NOTIFY THE COR OF ANY DISCREPANCIES BEFORE
CONTINUING WITH THE WORK.
e. CONDUIT ROUTING IS APPROXIMATE AND MUST BE COORDINATED
WITH EXISTING CONDITIONS. MAKE ADJUSTMENTS TO LOCATIONS
AS REQUIRED FOR PROPER ACCESS TO NEW JUNCTION BOXES
AND TO ANY EXISTING ITEMS REQUIRING ACCESS.
f. CONTRACTOR SHALL REMOVE EXISTING LAY-IN CEILING TILES
WHERE REQUIRED TO GAIN ACCESS FOR DEMOLITION AND NEW
WORK. PROTECT TILES AND RE-INSTALL AT END OF WORK DAY.
REPLACE ANY TILES DAMAGED DURING CONSTRUCTION.
HYPERCHLROINATION EQUIPMENT NOTES:
PROVIDE HYPERCHLORINATION INJECTION SPOOL PIECE
PER DETAIL A/PL-501 IN EXISITING 2" DCW PIPING.
PROVIDE HYPERCHLORINATION INJECTION SPOOL PIECE
PER DETAIL A/PL-501 IN EXISITING 2" DCW PIPING.
CL-06
CL-07
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text Approved: Project Director
AutoCAD SHX Text Project Title
AutoCAD SHX Text Date
AutoCAD SHX Text Location
AutoCAD SHX Text Checked
AutoCAD SHX Text Building Number
AutoCAD SHX Text Project Number
AutoCAD SHX Text Drawing Number
AutoCAD SHX Text Drawn
AutoCAD SHX Text Dwg. of
AutoCAD SHX Text Revisions:
AutoCAD SHX Text Date
AutoCAD SHX Text
CONSULTANTS:
Auto…
This is the start of the file's text. The full file is on GovTribe.