Asbestos Survey drawings.pdf

PDF 454 KB Posted

Attached to
Z2DA--36C249-21-AP-4236 - 626A4-18-102 - Renovate Restrooms
Solicitation number
36C24922B0004
Issued by

About this file

This document contains asbestos survey drawings and notes for buildings on the TVHS Alvin C. York Campus. The drawings identify the location and type of asbestos-containing materials present in buildings 6 and 4, including pipe and duct insulation, mastic, floor tiles, fire doors, and debris in steam tunnels. Notes indicate asbestos materials may be concealed and are present throughout the buildings.

The related federal contract opportunity is a solicitation between $500,000 to $1 million to renovate restrooms for the VA's Veterans Health Administration VISN 9. The solicitation number and opportunity details are provided.

View the file

Other files

Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DATE: OCTOBER 2009

SCALE: NTS

10 New England Business Center Drive, Suite 105 Andover, MA 01810

TF: (800) 659-1202

PH: (978) 688-3736

FAX: (978) 688-5494

www.efiglobal.com

TVHS, ALVIN C. YORK CAMPUS

ACM LOCATION DRAWING

BLDG #6, GROUND FLOOR

NOTES

1. ASBESTOS-CONTAINING PIPE & PIPE

FITTING INSULATION MAY BE

CONCEALED BEHIND WALLS, ABOVE

CEILINGS & WITHIN MECHANICAL

CHASES.

2. ASBESTOS-CONTAINING TRANSITE

PANELS ARE PRESENT WITHIN

RADIATOR UNITS THROUGHOUT

BUILDING.

3. ASBESTOS-CONTAINING TAR

COATING ON FIBERGLASS PIPE

INSULATION & DUCT INSULATION IS

PRESENT THROUGHOUT BUILDING.

4. PRESUMED ASBESTOS-CONTAINING

FIRE DOORS & ELEVATOR DOORS ARE

PRESENT THROUGHOUT BUILDING.

5. ASBESTOS-CONTAINING THERMAL

SYSTEMS INSULATION DEBRIS &

CONTAMINATED SOIL ARE PRESENT

THROUGHOUT BUILDING STEAM

TUNNELS (SEE STEAM TUNNEL

DRAWING).

LEGEND

= ASBESTOS-CONTAINING PIPE &

PIPE FITTING INSULATION

= ASBESTOS-CONTAINING

FLOOR TILE MASTIC UNDER

NON-ACM FLOOR TILE

10 New England Business Center Drive, Suite 105 Andover, MA 01810

TF: (800) 659-1202

PH: (978) 688-3736

FAX: (978) 688-5494

www.efiglobal.com

TVHS, ALVIN C. YORK CAMPUS

ACM LOCATION DRAWING

BLDG #6, 1ST FLOOR

NOTES

1. ASBESTOS-CONTAINING PIPE & PIPE

FITTING INSULATION MAY BE

CONCEALED BEHIND WALLS, ABOVE

CEILINGS & WITHIN MECHANICAL

CHASES.

2. ASBESTOS-CONTAINING TRANSITE

PANELS ARE PRESENT WITHIN

RADIATOR UNITS THROUGHOUT

BUILDING.

3. ASBESTOS-CONTAINING TAR

COATING ON FIBERGLASS PIPE

INSULATION & DUCT INSULATION IS

PRESENT THROUGHOUT BUILDING.

4. PRESUMED ASBESTOS-CONTAINING

FIRE DOORS & ELEVATOR DOORS ARE

PRESENT THROUGHOUT BUILDING.

5. ASBESTOS-CONTAINING THERMAL

SYSTEMS INSULATION DEBRIS &

CONTAMINATED SOIL ARE PRESENT

THROUGHOUT BUILDING STEAM

TUNNELS (SEE STEAM TUNNEL

DRAWING).

LEGEND

= ASBESTOS-CONTAINING PIPE &

PIPE FITTING INSULATION

= ASBESTOS-CONTAINING

10 New England Business Center Drive, Suite 105 Andover, MA 01810

TF: (800) 659-1202

PH: (978) 688-3736

FAX: (978) 688-5494

www.efiglobal.com

TVHS, ALVIN C. YORK CAMPUS

ACM LOCATION DRAWING

BLDG #6, 2ND FLOOR

NOTES

1. ASBESTOS-CONTAINING PIPE & PIPE

FITTING INSULATION MAY BE

CONCEALED BEHIND WALLS, ABOVE

CEILINGS & WITHIN MECHANICAL

CHASES.

2. ASBESTOS-CONTAINING TRANSITE

PANELS ARE PRESENT WITHIN

RADIATOR UNITS THROUGHOUT

BUILDING.

3. ASBESTOS-CONTAINING TAR

COATING ON FIBERGLASS PIPE

INSULATION & DUCT INSULATION IS

PRESENT THROUGHOUT BUILDING.

4. PRESUMED ASBESTOS-CONTAINING

FIRE DOORS & ELEVATOR DOORS ARE

PRESENT THROUGHOUT BUILDING.

5. ASBESTOS-CONTAINING THERMAL

SYSTEMS INSULATION DEBRIS &

CONTAMINATED SOIL ARE PRESENT

THROUGHOUT BUILDING STEAM

TUNNELS (SEE STEAM TUNNEL

DRAWING).

LEGEND

= ASBESTOS-CONTAINING PIPE &

PIPE FITTING INSULATION

= ASBESTOS-CONTAINING

10 New England Business Center Drive, Suite 105 Andover, MA 01810

TF: (800) 659-1202

PH: (978) 688-3736

FAX: (978) 688-5494

www.efiglobal.com

TVHS, ALVIN C. YORK CAMPUS

ACM LOCATION DRAWING

BLDG #6, 3RD FLOOR

NOTES

1. ASBESTOS-CONTAINING PIPE & PIPE

FITTING INSULATION MAY BE

CONCEALED BEHIND WALLS, ABOVE

CEILINGS & WITHIN MECHANICAL

CHASES.

2. ASBESTOS-CONTAINING TRANSITE

PANELS ARE PRESENT WITHIN

RADIATOR UNITS THROUGHOUT

BUILDING.

3. ASBESTOS-CONTAINING TAR

COATING ON FIBERGLASS PIPE

INSULATION & DUCT INSULATION IS

PRESENT THROUGHOUT BUILDING.

4. PRESUMED ASBESTOS-CONTAINING

FIRE DOORS & ELEVATOR DOORS ARE

PRESENT THROUGHOUT BUILDING.

5. ASBESTOS-CONTAINING THERMAL

SYSTEMS INSULATION DEBRIS &

CONTAMINATED SOIL ARE PRESENT

THROUGHOUT BUILDING STEAM

TUNNELS (SEE STEAM TUNNEL

DRAWING).

LEGEND

= ASBESTOS-CONTAINING MUD

PACKING ON FIBERGLASS

INSULATED PIPE ENDS, VALVES

& FLANGES

= ASBESTOS-CONTAINING

CLOTH DUCT CONNECTOR

OFFICE

OFFICE

OFFICE

TLT

STAIR

CORRIDOR

SUPV

LOBBY

TELE

DATA

TLT

PMRS

STOR

STOR

CORRIDOR

CONFERENCE

OFFICE

COORDINATOR

CHIEF

PMRS

REHAB

MULTI-PURPOSE

STOR

STOR

FILE

STORAGE

HALL

TLT

DRESSING

DRESSING

ELECTRICAL/

TLT

MECHSTORAGE

MECHANICAL

BO4

B03B02

B05

G117A

G117

G18

G116

G115

G113

G114

G112A

G111

G12

G108F

G108D

G108E

G18

G108C

G108B

G108

G108A

G01B

G01

G106

G107

G107BG107A

G103

G102

G105 G104

BUILDING 4 - BASEMENT

CONNECTING

CORRIDOR 3/4

CONNECTING

CORRIDOR 4/5

A A CUTLINE

FILE

OFFICE

MED

SERV/SEC

PREV

SWITCHBOARD

DATE: OCTOBER 2009

SCALE: NTS

10 New England Business Center Drive, Suite 105 Andover, MA 01810

TF: (800) 659-1202

PH: (978) 688-3736

FAX: (978) 688-5494

www.efiglobal.com

TVHS, ALVIN C. YORK CAMPUS

ACM LOCATION DRAWING

BLDG #4, GROUND FLOOR

NOTES

1. ASBESTOS-CONTAINING PIPE & PIPE

FITTING INSULATION MAY BE

CONCEALED BEHIND WALLS, ABOVE

CEILINGS & WITHIN MECHANICAL

CHASES.

2. PRESUMED ASBESTOS-CONTAINING

TRANSITE PANELS MAY BE PRESENT

WITHIN RADIATORS THROUGHOUT

BUILDING.

3. PRESUMED ASBESTOS-CONTAINING

FIRE DOORS & ELEVATOR DOORS ARE

PRESENT THROUGHOUT BUILDING.

4. ASBESTOS-CONTAINING PIPE FITTING

MASTIC IS PRESENT ON FIBERGLASS

INSULATED PIPING THROUGHOUT

BASEMENT MECHANICAL ROOM.

5. ASBESTOS-CONTAINING THERMAL

SYSTEMS INSULATION DEBRIS &

CONTAMINATED SOIL ARE PRESENT

THROUGHOUT THE BUILDING STEAM

TUNNELS (SEE STEAM TUNNEL

DRAWING).

LEGEND

= ASBESTOS-CONTAINING

FLOOR TILE & ASSOCIATED

MASTIC

= ASBESTOS-CONTAINING PIPE

& PIPE FITTING INSULATION

= ASBESTOS-CONTAINING AIR

HANDLING UNIT INSULATION

MASTIC

RESEARCH

STAIRWELL

TOILET

RESEARCH

RESEARCH

BALCONY

STORAGE

BELOW

STAGE

ROOFROOF

ROOFROOF ROOF ROOF

FILE

(BELOW)

DATE: OCTOBER 2009

SCALE: NTS

10 New England Business Center Drive, Suite 105 Andover, MA 01810

TF: (800) 659-1202

PH: (978) 688-3736

FAX: (978) 688-5494

www.efiglobal.com

TVHS, ALVIN C. YORK CAMPUS

ACM LOCATION DRAWING

BLDG #4, 1ST FLOOR

NOTES

1. ASBESTOS-CONTAINING PIPE & PIPE

FITTING INSULATION MAY BE

CONCEALED BEHIND WALLS, ABOVE

CEILINGS & WITHIN MECHANICAL

CHASES.

2. PRESUMED ASBESTOS-CONTAINING

TRANSITE PANELS MAY BE PRESENT

WITHIN RADIATORS THROUGHOUT

BUILDING.

3. PRESUMED ASBESTOS-CONTAINING

FIRE DOORS & ELEVATOR DOORS ARE

PRESENT THROUGHOUT BUILDING.

4. ASBESTOS-CONTAINING THERMAL

SYSTEMS INSULATION DEBRIS &

CONTAMINATED SOIL ARE PRESENT

THROUGHOUT THE BUILDING STEAM

TUNNELS (SEE STEAM TUNNEL

DRAWING).

LEGEND

= ASBESTOS-CONTAINING

BLACK TAR SEALANT / MASTIC

ON FIBERGLASS DUCT

INSULATION

File details come from the government source that posted it. Updated .