14.08_EP001B - BASEMENT ELECTRICAL PLAN-B.pdf
PDF 260 KB Posted
- Attached to
- Upgrade 480V Electrical System Federal contract opportunity
- Solicitation number
- 36C24921R0084
About this file
This package includes construction drawings and specifications for an electrical system upgrade project at a Department of Veterans Affairs medical facility. The project scope involves installing a new 1150 KVA transformer and pad, upgrading the 480V electrical system, correcting wiring deficiencies for CAT scan rooms, and moving electrical feeds for several air handlers and associated chilled water pumps and controls to emergency power circuits. Key project components include installing a new outdoor 480V transformer, upgrading the 480V switchgear, and performing electrical work in the basement, sub-basement, and various facility floors as depicted in the drawings. The solicitation is a pre-solicitation for a firm fixed price contract to complete all work per the specifications and drawings.
View the file
Other files for this federal contract opportunity
Show all 50
Upgrade 480V Electrical System has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP DOWN
FIRE
EQUIPMENT
CLOSET
A-021
A-020 H.A.C.
H.V.A.C.
EQUIPMENT
A-012
CLOSET
ELECTRIC
A-001
A&MM
A-017a
REPRODUCTION
MAIL ROOM
B-001
A-018
ROOM
DECONTAMINATION
H.V.A.C.
INCOMING
INSPECTION
ROOM
A-027
A-033h
CLOSET
ELECTRIC
A-033e
AREA
WORK
A-034
ROOM
BREAK
S-5
S-5
P-4
A-022
LOBBY
ELEVATOR
A-022a
CLOSET
ELECTRIC
A-033f
OFFICE
A-033g
OFFICE
A-024
ROOM
EQUIPMENT
A-025
STORAGE
SAFETY
P-3
P-2
P-1
A-033
PHARMACY
IN-PATIENT
A-032
LINEN
SOILED
A-026
STORAGE
A-028
BREAK ROOM
PHARMACY
A-031e
STORAGE
A-029 #6
STAIRWELL
F.A.C.
A-029a
BASEMENT
SUB-
MATERIAL
STORAGE
B-039b
INSTRUMENT
PREPARATION
ROOM
B-039
LIFT
CLOSET
ENG
A-017d
STORAGE
A-005
SOILED
LINEN
A-004 MEN'S
RESTROOM
A-003 WOMEN'S
RESTROOM
A-002
VOLUNTEER
ESCORT
A-006
NTER
N IN
PHARMACY
STORAGE
A-011
CAGE
A-011a
STAIRWELL #1
A-014
COMM
CLOSET
A-013
TELEPJONE
CLOSET
A-015
OFFICE
A-017c
ROOM
A-017b
SUB-BAS
A-010a
STAIRWELL #2
A-010
E
ROOM
A-017
A-016f
HOLDING
A-016e
ROOM
BREAK HVAC
EQUIP
A-016g
A-016c
STORAGE
A-016d
ASSISTANT
PROGRAM
A-016a
ROOM
RADIO
POLICE
OFFICE
A-016
A-016b
OFFICE
CHIEF POLICE
STERILE
SUPPLY
STORAGE
A-019b
A-023a
OFFICE
A-023
WAREHOUSE
A-019d
OFFICE
A-019c
AREA
BREAKDOWN
A-019
STORAGE
MATERIALS MANAGEMENT
A-019a
ROOM
EQUIPMENT
CART
WASH
A-018b
S S B-039c
SILVER
RECOVERY
A-005a
STORAGE
A-005b
STORAGE
A-011a
A-001a
ELECTRICAL
B-001
WP/GF
(EX)
PNL REF
(EX)
PNL DAC-S 480V
(EX)
PNL EEQD
SPS AH-43
/1 EP001A/1 EP001A
(EX)
PNL HB
ALT #1
ON RAISED PLATFORM
ALT #1
ALT #1
SUB A001
OATC PANEL 2ACT DISCONNECT
MCC A001
EF-43
EEQD - 2,4,6
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD FFE Inc Engineering and Technical Services 110 Boggs Lane, Suite 170 Springdale, OH 45246 513-522-0956
STAMPCONSULTANT
321 4 5 6 7 8 9 10
603-20-505
Louisville, KY
UPGRADE 480V
ELECTRICAL SYSTEM
C :\U se rs
\J ac k\ D oc um en ts
\L ou is vi lle
U pg ra de
V El ec S ys te m (2
8)
_j ac k.
bo nb rig ht T4
3D B.
rv t
3/
/2
2:
:4
PM
EP001B
BASEMENT ELECTRICAL PLAN-B
03/01/21 JB HT
1/8" = 1'-0"1 PARTIAL BASEMENT ELECTRICAL PLAN - B
K E Y N O T E S
1 TRANSFER CKT #1 ELECTRICAL RISER AHU 6,7,9,12 & 13 IN PANEL
DAC-S TO 100A/3P BKR IN PANEL EEQC. USE 3#2 AWG, #8 GND, 1-1/4"C.
REMOVE WIRES FROM PANEL. PROVIDE JUNCTION BOX. SPLICE
BRANCH CIRCUIT WIRE AND EXTEND CONDUIT TO EMERGENCY PANEL
EEQC.
2 TRANSFER 30A/3P CKT IN PANEL HB FOR CHILLED WATER PUMPS FROM
BASEMENT THRU SECOND FLOORS TO PANEL EEQC. USE 3#10AWG,
#10GND, 3/4"C. REMOVE WIRES FROM PANEL. PROVIDE JUNCTION BOX.
SPLICE BRANCH CIRCUIT WIRE AND EXTEND CONDUIT TO EMERGENCY
PANEL EEQC.
3 TRANSFER 80A/3P CKT IN PANEL HB FOR CHILLED WATER PUMPS FROM
THIRD THRU EIGHTH FLOORS TO PANEL EEQC. USE 3#3AWG, #8GND,
1-1/4"C. REMOVE WIRES FROM PANEL. PROVIDE JUNCTION BOX. SPLICE
BRANCH CIRCUIT WIRE AND EXTEND CONDUIT TO EMERGENCY PANEL
EEQC.
4 CHANGE THE BREAKER PLUG TO 400A RATED 65KA SQUARE D
MICROLOGIC 6.0A UNIT. MASTER PACT BREAKER. PROVIDE DOUBLE
LUGS.
5 REFEED PANEL OACT WITH PARALLEL 4- 3/0 AWG, #3 GROUND. REUSE
EXISTING CONDUIT AND ADD A 2” EMT TO PANEL. REFEED AC-1 FROM
OACT 30A/3P SQUARE D I-LINE BREAKER. REFEED CU-1 FROM OACT.
20A/2P I-LINE BREAKER. BOTH CIRCUITS CURRENTLY FED FROM PANEL
NH-1. FOR CT SCANNER IN ROOM A-226.
6 POWER PANEL EEQD IS FED FROM THE FEED-THROUGH LUGS OF
PANEL EEQC. SEE SHEET E500.
1/8" = 1'-0"2 PARTIAL ELECTRICAL FOURTH FLOOR PLAN
Revisions: Date:
SCHEMATIC DESIGN 25% 11/06/20
BID DOCUMENTS 100% 03/12/21
G E N E R A L N O T E S
03/12/2021
BASE BID:
PROVIDE ALL WORK SHOWN ON DRAWINGS AND SPECIFICATIONS
DEDUCT ALTERNATES
ALT #1:
DEDUCT ALL ELECTRICAL WORK ASSOCIATED FOR ELECTRICAL RISER FOR AHU - 3, 5, 6, 7, 9, 12 AND 13. (PANELBOARD DAC-S) ELECTRICAL RISER FOR CHILLED WATER PUMP (PANELBOARD HB).
DEDUCT WORK FOR HVAC PUMPS. CONTROLS FOR AHU - 3, 5, 6, 7, 9, 12 AND 13. DEDUCT WORK FOR AHU-43 SUPPLY
FAN & EXHAUST FAN.
ALT #2:
DEDUCT ALL ELECTRICAL WORK CHILLED WATER PUMPS FOR AHU - 17, 23, 43.
ALT #3:
DEDUCT ALL ELECTRICAL WORK FOR CHILLED WATER PUMPS FOR AHU - 4A AND AHU - 8A (MCC IN ROOMS M-003).
PUMPS P1, P2, P3, P4. AHU - 8A AND EF8 MCC IN ROOM C-220.
ALT #4:
DEDUCT ALL ELECTRICAL WORK FOR AHU - 42 AND DX - 42 (PANELBOARD DP)
| Sheets |
| AE101 - SCREEN WALL DETAILS |
| E001 - LEGEND |
| E500 - SCHEDULES, DETAILS AND SINGLE-LINE DIAGRAM |
| E501 - PARTIAL MEDIUM VOLTAGE SINGLE-LINE DIAGRAM |
| E600 - PANEL SCHEDULES |
| EP000 - OVERALL BASEMENT ELECTRICAL PLAN |
| EP0000 - OVERALL SUB-BASEMENT PLAN |
| EP0001 - SUB-BASEMENT ELECTRICAL PLAN |
| EP001A - BASEMENT ELECTRICAL PLAN-A |
| EP001B - BASEMENT ELECTRICAL PLAN-B |
| EP100 - OVERALL FIRST FLOOR PLAN |
| EP101 - FIRST FLOOR ELECTRICAL PLAN |
| EP200 - OVERALL SECOND FLOOR PLAN |
| EP201 - SECOND FLOOR ELECTRICAL PLAN |
| EP300 - OVERALL THIRD FLOOR PLAN |
| EP400 - OVERALL FOURTH FLOOR PLAN |
| EP500 - OVERALL FIFTH FLOOR PLAN |
| EP600 - OVERALL SIXTH FLOOR PLAN |
| EP700 - OVERALL SEVENTH FLOOR PLAN |
| EP800 - OVERALL EIGHT FLOOR PLAN |
| EP900 - OVERALL NINTH FLOOR PLAN |
| ES100 - ELECTRICAL SITE PLAN |
| GI000 - COVER SHEET AND SHEET INDEX |
File details come from the government source that posted it. Updated .