047200 CAST STONE MASONRY.pdf

PDF 137 KB Posted

Attached to
Upgrade 480V Electrical System Federal contract opportunity
Solicitation number
36C24921R0084
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 9

About this file

This technical specification outlines requirements for cast stone masonry to be installed as part of an electrical system upgrade project at the Robley Rex VA Medical Center in Louisville, Kentucky. The specification details product standards, submittal requirements, manufacturing tolerances, raw materials, colors and finishes, reinforcing, curing processes, installation procedures, repairs and cleaning expectations. It requires cast stone units to meet or exceed specifications for compressive strength, absorption rates, air content, freeze-thaw resistance and linear shrinkage. The contractor shall furnish all material, equipment and labor necessary to install a new 1150 KVA outdoor transformer with pad and barrier walls, upgrade the 480V electrical system per drawings and specifications, install new wiring for CAT scan rooms, and relocate feeds for air handlers and associated equipment to emergency power circuits.

View the file

Other files for this federal contract opportunity

Other files attached to Upgrade 480V Electrical System, newest first.
File Type Posted
KY20210093 Wage Determination.pdf PDF
Pad-mount Med V Xforms.pdf PDF
36C24921R0084 0003.pdf PDF
36C24921R0084_1.pdf PDF
36C24921R0084 0002.pdf PDF
36C24921R0084 0001.pdf PDF
260511 Req Electric.pdf PDF
033053 Cast in Place Conrete.pdf PDF
013216-15 Schedules 2.pdf PDF
013323 Shop Drawings.pdf PDF
014219 Ref Standards.pdf PDF
14.20_ES100 - ELECTRICAL SITE PLAN.pdf PDF
14.18_EP800 - OVERALL EIGHT FLOOR PLAN.pdf PDF
14.15_EP500 - OVERALL FIFTH FLOOR PLAN.pdf PDF
14.09_EP100 - OVERALL FIRST FLOOR PLAN.pdf PDF
14.17_EP700 - OVERALL SEVENTH FLOOR PLAN.pdf PDF
14.08_EP001B - BASEMENT ELECTRICAL PLAN-B.pdf PDF
14.00_E001 - LEGEND.pdf PDF
265600 Ext Lighting.pdf PDF
312011 Earthwork.pdf PDF
260526 Grounding and Bonding.pdf PDF
260533 Raceway and Boxes.pdf PDF
262413 Distribution Switchboard.pdf PDF
260513 Med Voltage Cables.pdf PDF
018113 Sustainable Construction Requirements.pdf PDF
040516 Masonry Grouting2.pdf PDF
14.10_EP101 - FIRST FLOOR ELECTRICAL PLAN.pdf PDF
14.14_EP400 - OVERALL FOURTH FLOOR PLAN.pdf PDF
14.05_EP0001 - SUB-BASEMENT ELECTRICAL PLAN.pdf PDF
14.19_EP900 - OVERALL NINTH FLOOR PLAN.pdf PDF
14.12_EP201 - SECOND FLOOR ELECTRICAL PLAN.pdf PDF
14.01_E500 - SCHEDULES, DETAILS AND SINGLE-LINE DIAGRAM.pdf PDF
S15-PPQ-Template (Project 603-20-505) Upgrade 480V Electrical System.pdf PDF
323113 Chain Link Gates.pdf PDF
010000 Gen Requirments Rev 2.pdf PDF
000115 List Drawing.pdf PDF
040513 Masonry Mortaring.pdf PDF
042000 Unit Masonry.pdf PDF
017419 Const Waste Management.pdf PDF
000110 TOC.pdf PDF
00.00_GI000 - COVER SHEET AND SHEET INDEX.pdf PDF
14.07_EP001A - BASEMENT ELECTRICAL PLAN-A.pdf PDF
07.00_AE101 - SCREEN WALL DETAILS.pdf PDF
14.06_EP000 - OVERALL BASEMENT ELECTRICAL PLAN.pdf PDF
14.02_E501 - PARTIAL MEDIUM VOLTAGE SINGLE-LINE DIAGRAM.pdf PDF
S02-36C24921R0084_1.pdf PDF
263623 ATS.pdf PDF
264313 Surge Prot Dev.pdf PDF
260541 Underground Elec Const.pdf PDF
S03-Successful FBO Posting-36C24921R0084 (603-20-505).pdf PDF
Show all 50

Upgrade 480V Electrical System has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Louisville KY - Robley Rex VAMC – Upgrade 480V Electrical System

Project #: 603-20-505

02-01-15

04 72 00 - 1

SECTION 04 72 00

CAST STONE MASONRY

PART 1 - GENERAL

1.1 DESCRIPTION

A. This sections specifies manufactured concrete units to simulate a natural stone.

B. Installation of cast stone units.

1.2 RELATED WORK

A. Setting and pointing mortar: Section 04 05 13, MASONRY MORTARING /

Section 04 05 16, MASONRY GROUTING.

B. Joint sealant and application: Section 07 92 00, JOINT SEALANTS.

1.3 SUBMITTALS

A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT

DATA, AND SAMPLES.

B. Samples:

1. Cast stone, sample panel, size 100 by 300 by 300 mm (4 by 12 by 12 inches) each color and finish.

2. Show finish on two 100 mm (4-inch) edges and 300 by 300 mm (12 by 12 inch) surface.

C. Shop Drawings:

1. Cast stone showing exposed faces, profiles, cross sections, anchorage, reinforcing, jointing and sizes.

2. Setting drawings with setting mark.

D. Certificates: Test results indicating that the cast stone meets specification requirements and proof of plant certification.

E. Submit manufacturers test results of cast stone previously made by manufacturer.

1.4 PRODUCT DELIVERY, STORAGE AND HANDLING

A. Store cast stone under waterproof covers on planking clear of ground.

B. Protect from handling, dirt, stain, and water damage.

C. Mark production units with the identification marks as shown on the shop drawings.

D. Package units and protect them from staining or damage during shipping and storage.

E. Provide an itemized list of product to support the bill of lading.

04 72 00 - 2

1.5 WARRANTY

Warranty exterior masonry walls against moisture leaks, any defects and subject to terms of "Warranty of Construction", FAR clause 52.246-21, except that warranty period shall be two years.

1.6 APPLICABLE PUBLICATIONS

A. Publications listed below form a part of this specification to extent referenced. Publications are referenced in text by the basic designation only. Comply with applicable provisions and recommendations of the following, except as otherwise shown or specified.

B. Cast Stone Institute Technical Manual and Cast Stone Institute standard specifications.

C. American Society for Testing and Materials (ASTM):

A167-99(R2009)..........Stainless and Heat Resisting Chromium-Nickel

Steel Plate, Sheet, and Strip

A185-07.................Steel, Welded Wire Fabric, Plain for Concrete

A615/A615M-09...........Deformed and Plain Billet-Steel Bars for

Concrete Reinforcement

C33-11..................Concrete Aggregates

C150-09.................Portland Cement

C503-10.................Marble Dimension Stone (Exterior)

C568-10.................Limestone Dimension Stone

C615-11.................Granite Dimension Stone

C616-10.................Quartz-Based Dimension Stone

C979-10.................Pigments for Integrally Colored Concrete

C1194-03................Compressive Strength of Architectural Cast

Stone

C1195-03................Absorption of Architectural Cast Stone

C1364-10................Architectural Cast Stone.

D2244-09................Calculation of Color Differences from

Instrumentally Measured Color Coordinates.

1.7 QUALITY ASSURANCE

A. The Manufacturer:

1. Must have 3 years minimum continuous operating experience and have facilities for manufacturing cast stone as described herein.

Manufacturer shall have sufficient plant facilities to produce the shapes, quantities and size of cast stone required in accordance with the project schedule.

04 72 00 - 3

2. Must be a member of the Cast Stone Institute.

3. Must have a certified plant (certification by the Cast Stone

Institute).

B. Stone setter: Must have 3 years’ experience setting cast or natural building stone.

1.8 MANUFACTURING TOLERANCES

A. Cross section dimensions shall not deviate by more than + 1/8 in. (3

mm) from approved dimension.

B. Length of units shall not deviate by more than length /360 or + 1/8 in.

(3mm), whichever is greater, not to exceed + 1/4 in (6 mm). Maximum length of any unit shall not exceed 15 times the average thickness of such unit unless otherwise agreed by the manufacturer.

C. Warp bow or twist of units shall not exceed length/360 or + 1/8 in. (3 mm), whichever is greater.

D. Location of dowel holes, anchor slots, flashing grooves, false joints and similar features – On formed sides of unit, 1/8 in (3 mm), on unformed sides of unit, 3/8 in (9 mm) maximum deviation.

PART 2 - PRODUCTS

2.1 ARCHITECTURAL CAST STONE

A. Comply with ASTM C 1364

B. Physical properties: Provide the following:

1. Compressive Strength – ASTM C 1194: 6,500 psi (45 Mpa) minimum for products at 28 days.

2. Absorption – ASTM C 1195: 6% maximum by the cold water method, or

10% maximum by the boiling method for products as 28 days.

3. Air Content – ASTM C173 or C231, for wet cast product shall be 4-8% for units exposed to freeze-thaw environments. Air entrainment is not required for vibrant dry tamp (VDT) products.

4. Freeze thaw - ASTM C 1364L The cumulative percent weight loss (CPWL) shall be less than 5% after 300 cycles of freezing and thawing.

5. Linear Shrinkage - ASTM C 426L Shrinkage shall not exceed 0.065%.

C. Job site testing – One (1) sample from production units may be selected at random from the field for each 500 cubic feet (14m3) delivered to the job site:

1. Three (3) field cut cube specimens from each of these samples shall have an average minimum compressive strength of not less than 85%

04 72 00 - 4 with no single specimen testing less than 75% of design strength as allowed by ACI 318.

2. Three (3) field cut cube specimens from each of these samples shall have an average maximum cold-water absorption of 6%.

3. Field specimens shall be tested in accordance with ASTM C 1194 and C

1195.

2.2 RAW MATERIALS

A. Portland cement – Type I or Type III, white and/or grey, ASTM C 150.

B. Coarse aggregates – Granite, quartz or limestone, ASTM C 33, except for gradation, and are optional for the vibrant dry tamp (VDT) casting method.

C. Fine aggregates – Manufactured or natural sands, ASTM C 33, except for gradation.

D. Colors – Inorganic iron oxide pigments, ASTM C 979 except that carbon black pigments shall not be used.

E. Admixtures- Comply with the following:

1. ASTM C 260 for air-entraining admixtures.

2. ASTM C 494/C 495 M Types A-G for water reducing, retarding, accelerating and high range admixtures.

3. Other admixtures: integral water repellents and other chemicals, for which no ASTM Standard exists, shall be previously established as suitable for use in concrete by proven field performance or through laboratory testing.

4. ASTM C 618 mineral admixtures of dark and variable colors shall not be used in surfaces intended to be exposed to view.

5. ASTM C 989 granulated blast furnace slag may be used to improve physical properties. Tests are required to verify these features.

F. Water – Potable

G. Reinforcing bars:

1. ASTM A 615/A 615M. Grade 40 or 60 steel galvanized or epoxy coated when cover is less than 1.5 in. (37 mm).

2. Welded Wire Fabric: ASTM A 185 where applicable for wet cast units.

H. All anchors, dowels and other anchoring devices and shims shall be standard building stone anchors commercially available in a non-corrosive material such as zinc plated, galvanized steel, brass, or stainless steel Type 302 or 304.

04 72 00 - 5

2.3 COLOR AND FINISH

A. Match existing stone veneer on building.

B. All surfaces intended to be exposed to view shall have a fine-grained texture similar to natural stone, with no air voids in excess of 1/32

in. (0.8 mm) and the density of such voids shall be less than 3 occurrences per any 1 in2 (25mm2) and not obvious under direct daylight illumination at a 5 ft. (1.5m)distance.

C. Units shall exhibit a texture approximately equal to the approved sample when viewed under direct daylight illumination at a 10 ft (3m) distance.

D. ASTM D 2244 permissible variation in color between units of comparable age subjected to similar weathering exposure.

1. Total color difference – not greater than 6 units.

2. Total hue difference-not greater than 2 units.

2.4 REINFORCING

A. Reinforce the units as required by the drawings and for safe handling and structural stress.

1. Minimum reinforcing shall be 0.25 percent of the cross section area.

B. Reinforcement shall be non-corrosive where faces exposed to weather are covered with less than 1.5in. (38 mm) of concrete material. All reinforcement shall have minimum coverage of twice the diameter of the bars.

C. Minor chipping resulting from shipment and delivery shall not be grounds for rejection. Minor chips shall not be obvious under direct daylight illumination from a 20-ft (6m) distance.

D. The occurrence of crazing or efflorescence shall not constitute a cause for rejection.

E. Remove cement film, if required, from exposed surface prior to packaging for shipment.

2.5 CURING

Cure units in a warm curing chamber 100 F (37.8 C) at 95 percent relative humidity for approximately 12hours, or cure in a 95 percent moist environment at a minimum 70F (21.1 C) for 16 hours after casting.

Additional yard curing at 95 percent relative humidity shall be 350-degree-days (i.e. 7 days @ 50F (10.0 C) or 5 days @ 70F (21.0 C) prior to shipping. Form cured units shall be protected from moisture evaporation with curing blankets or curing compounds after casting.

04 72 00 - 6

PART 3 - EXECUTION

3.1 EXAMINATION

Installing contractor shall check cast stone materials for fit and finish prior to installation. Do not set unacceptable units.

3.2 SETTING TOLERANCES

A. Comply with Cast Stone Institute SM Technical Manual.

B. Set stones 1/8 in. (3 mm) or less, within the plane of adjacent units.

C. Joints, plus – 1/6 in. (1.5 mm), minus – 1/8 in. (3 mm).

3.3 JOINTING

A. Joint size:

1. At stone/brick joints 3/8 in. (9.5 cm).

2. At stone/stone joints in vertical position 1/4 in. (6 mm) (3/8 in.

(9.5 mm) optional).

3. Stone/stone joint exposed on top 3/8 in. (.5 mm).

B. Joint Materials:

1. Mortar, Type N, ASTM C 270.

2. Use a full bed of mortar at all bed joints.

3. Flush vertical joints full with mortar.

4. Leave all joints with exposed tops or under relieving angles open for sealant.

5. Leave head joints in coping and projecting components open for sealant.

C. Location of joints:

1. As shown on shop drawings.

2. At control and expansion joints unless otherwise shown.

3.4 SETTING

A. Drench units with clean water prior to setting.

B. Fill dowel holes and anchor slots completely with mortar or non-shrink grout.

C. Set units in full bed of mortar, unless otherwise detailed.

D. Rake mortar joints 3/4 in. (18 mm) in. for pointing.

E. Remove excess mortar from unit faces immediately after setting.

F. Tuck point unit joints to a slight concave profile.

3.5 JOINT PROTECTION

A. Comply with requirements of Section 07 92 00, JOINT SEALANTS.

B. Prime ends of units, insert properly sized backing rod and install required sealant.

04 72 00 - 7

3.6 REPAIR AND CLEANING

A. Repair chips with touchup materials furnished by manufacturer.

B. Saturate units to be cleaned prior to applying an approved masonry cleaner.

C. Consult with manufacturer for appropriate cleaners.

3.7 INSPECTION AND ACCEPTANCE

Inspect finished installation according to Bulletin #36 published by the Cast Stone Institute.

- - - E N D - - -