36C24920R0043-0006002.pdf
PDF Posted
- Solicitation number
- 36C24920R0043
About this file
This pre-solicitation notice is for upgrade elevator projects at the Alvin C. York VA Medical Center in Murfreesboro, Tennessee. The Department of Veterans Affairs intends to issue a request for proposals with an anticipated posting date of January 24, 2020. The project magnitude is estimated between $2 million to $5 million. The NAICS code is 236220 and it is set aside 100% for Service-Disabled Veteran-Owned Small Businesses. The contractor shall provide all labor, materials, equipment, and supervision to completely prepare the site and upgrade the elevators in three buildings in accordance with the specifications and drawings. The construction completion period is 360 calendar days.
36C24920R0043 0006 Addendum 1 Arch set_signed.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24920R0043-0008005.pdf | ||
| 36C24920R0043-0008004.pdf | ||
| 36C24920R0043-0008002.pdf | ||
| 36C24920R0043-0008001.pdf | ||
| 36C24920R0043-0008003.pdf | ||
| 36C24920R0043-0008000.docx | DOCX document | |
| 36C24920R0043-0007001.pdf | ||
| 36C24920R0043-0007000.docx | DOCX document | |
| 36C24920R0043-0006001.docx | DOCX document | |
| 36C24920R0043-0006004.pdf | ||
| 36C24920R0043-0006000.docx | DOCX document | |
| 36C24920R0043-0006003.pdf | ||
| 36C24920R0043-0005000.docx | DOCX document | |
| 36C24920R0043-0004000.docx | DOCX document | |
| 36C24920R0043-0003000.docx | DOCX document | |
| 36C24920R0043-0002000.docx | DOCX document | |
| 36C24920R0043-0001000.docx | DOCX document | |
| 36C24920R0043-006.xlsx | XLSX spreadsheet | |
| 36C24920R0043-003.docx | DOCX document | |
| 36C24920R0043-004.pdf | ||
| 36C24920R0043-005.pdf | ||
| 36C24920R0043-008.docx | DOCX document | |
| 36C24920R0043-007.pdf |
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LA
R
E GI H, N
C
N
11664
I K
G HC OY
R
EG
IS
TE
RED ARCH
ITEC
T
N O R
T H
CA RO
L
I N
AA
LA
R
E GI H,NC
S
G O 52644
P E
N
CO
LU IT
E
NG
RG
U O
A
P ,P
R E
G I
S T
E R
E D
A R
C H I T E C T U R
A L
C O
R P
O T
I O
N
N O
R T H C A R O L
I N
A
A R
12'-2"
11'-3"
9'-3"
11'-5" 8'
VETERANS BLVD
VETERANS CIRCLE
VETERANS CIRCLE
S A
M
JA
R E
D R
O A
D
VETERANS CIRCLE
VETERANS CIRCLE
EAST MAIN STREET
E A
S T
V
IE
W D
R
IV
E
N O
R T
H V
IE
W
D R
IV
E
BOILER PLANT RD
PARK ROAD
PARK ROAD
GARDEN DRIVE
JOHN F COADY DRIVE
JOHN F COADY DRIVE
LAKE ROAD
HILL STREET
R
IV
E R
R O
A D
R
IV
E R
R O
A D
FLAMABLE STORAGE
CHOP
HOUSE
Architectural and Engineering Services to Upgrade Elevators Buildings 8, 9 and 10
Alvin C. York VA Medical Center 3400 Labanon Pike Murfreesboro, TN 37129
VA PROJECT NO. 626A4-18-203
CONSTRUCTION
STAGING AREA
BUILDING 8
N
SITE NOTES
1. WORKING SPACE AND SPACE AVAILABLE FOR STORING
MATERIALS SHALL BE AS DETERMINED BY THE COR
2. KEEP ROADS CLEAR OF CONSTRUCTION MATERIAL, DEBRIS,
STANDING CONSTRUCTION EQUIPMENT AND VEHICLES AT ALL
TIMES. DO NOT STORE MATERIALS AND EQUIPMENT IN OTHER
THAN ASSIGNED AREAS.
3. SCHEDULE DELIVERY OF MATERIALS AND EQUIPMENT TO
IMMEDIATE CONSTRUCTION WORKING AREAS IN QUANTITIES
SUFFICIENT FOR NOT MORE THAN TWO WORK DAYS. PROVIDE
UNOBSTRUCTED ACCESS TO MEDICAL CENTER AREAS
REQUIRED TO REMAIN IN OPERATION.
4. COORDINATE WITH COR FOR REMOVAL OF EXISTING
FURNISHINGS AND EQUIPMENT TO PERMIT WORK TO
PROCEED. CONTRACTOR SHALL PROVIDE THE COR WITH A
COPY OF THEIR LOTO PROCEDURE WITHIN TEN DAYS OF
RECEIVING THE NTP.
5. COORDINATE THE WORK FOR THIS CONTRACT WITH OTHER
CONSTRUCTION OPERATIONS AS DIRECTED BY COR. THIS
INCLUDES THE SCHEDULING OF TRAFFIC AND THE USE OF
ROADWAYS, AS SPECIFIED IN ARTICLE, USE OF ROADWAYS.
6. UTILITIES SERVICES: MAINTAIN EXISTING UTILITY SERVICES FOR
MEDICAL CENTER AT ALL TIMES. PROVIDE TEMPORARY
FACILITIES, LABOR, MATERIALS, EQUIPMENT, CONNECTIONS,
AND UTILITIES TO ASSURE UNINTERRUPTED SERVICES AS
REQUIRED BY THE DRAWINGS AND SPECIFICATIONS. WHERE
NECESSARY TO CUT EXISTING WATER, STEAM, GASES, SEWER
OR AIR PIPES, OR CONDUITS, WIRES, CABLES, ETC. OF UTILITY
SERVICES OR OF FIRE PROTECTION SYSTEMS AND
COMMUNICATIONS SYSTEMS (INCLUDING TELEPHONE), THEY
SHALL BE CUT AND CAPPED AT SUITABLE PLACES WHERE
SHOWN; OR, IN ABSENCE OF SUCH INDICATION, WHERE
DIRECTED BY COR.
7. OBTAIN ASBESTOS ABATEMENT PLANS FROM VA COR PRIOR
TO START OF WORK. COMPLETE WORK FOR ASBESTOS
ABATEMENT PRIOR TO THE START OF CONSTRUCTION OR
DEMOLITION. REFER TO SPECIFICATIONS FOR REQUIREMENTS
FOR ASBESTOS ABATEMENT.
8. THE CONTRACTOR WILL TRANSPORT MATERIALS IN AND OUT
OF THE BUILDING THROUGH THE WINDOWS IN THE FRONT OF
THE BUILDING O THE FIRST AND SECOND FLOORS. CERTIFIED
SCAFFOLDING AND SCAFFOLDING STAIRS WILL BE USED TO
GAIN ACCESS INTO THE WORK AREAS. WORK AREAS WILL BE
LOCKED DOWN AFTER CONSTRUCTION HOURS. COORDINATED
EXACT LOCATIONS WITH THE VA COR.
9. ELEVATOR ACCESS IS PROHIBITED AS A CONSTRUCTION PATH.
NO CONSTRUCTION MATERIALS, TOOLS OR WASTE WILL BE
TRANSPORTED VIA ELEVATOR. PLEASE USE THE DESIGNATED
CONSTRUCTION ACCESS POINTS.
10. SECURE CONSTRUCTION STAGING AREAS WITH A FENCE.
STAGING AREA WILL BE LOCKED DOWN DURING OFF HOURS.
CONSTRUCTION
STAGING AREA
BUILDING 10
CONSTRUCTION
STAGING AREA
BUILDING 9
Revisions: Date
Drawing Title:
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER:
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs#
/6
/2
:2
:5
P M
G-001
COVER SHEET
1 10KC HM, GTS
Architectural and Engineering Services to Upgrade Elevators
Buildings 8, 9 and 10
Alvin C. York VA Medical Center 3400 Labanon Pike
Murfeesboro, TN 37129 12/04/2019
FINAL BID DOCUMENTS
626A4-18-20318-028
8, 9 & 10
NORTH
TRUE
Scale: 1" = 160'-0"
CAMPUS MAP
DEDUCT ALTERNATE:
BUILDING 10 IN ITS ENTIRETY.
1 ADDENDUM 1 05/06/2020
DocuSign Envelope ID: 98E6A7C2-D697-410A-882E-3461219738EF
5/6/2020
A
B
C
D
E
F
G
H
I
J
2 3 4 5 6 7 8 9
V.I.F.
35'-8 1/2"
EXISTING
ELEVATOR
(BELOW)
/2
/2
/2
V.I.F.
7 1/2"
10'-6" V.I.F.
6"
PENTHOUSE
EXISTING
ELEVATOR
EQUIPMENT
ROOM
EXISTING STAIR
DOWN TO 2ND
FLOOR LEVEL
NEW MACHINE FOR
ELEVATOR, REFER
TO ELEVATOR
SPECIFICATIONS
FOR SIZE AND
LOCATION
A-701
P8
FEC
MACHINE
ROOM
A
LA
R
E GI H,NC
S
G O 52644
P E
N
CO
LU IT
E
NG
RG
U O
A
P ,P
R E
G I
S T
E R
E D
A R
C H I T E C T U R
A L
C O
R P
O T
I O
N
N O
R T H C A R O L
I N
A
A R
LA
R
E GI H, N
C
N
11664
I K
G HC OY
R
EG
IS
TE
RED ARCH
ITEC
T
N O R
T H
CA RO
L
I N A
# KEY NOTES:
Revisions: Date
Drawing Title:
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER:
SHEET NOTES:
WALL RATING LEGEND
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs#
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREAS S S S
/6
/2
:2
:4
P M
A-103
ROOF PLAN AT PENTHOUSE - BUILDING
6 19KC HM
Architectural and Engineering Services to Upgrade Elevators
Buildings 8, 9 and 10
Alvin C. York VA Medical Center 3400 Labanon Pike
Murfeesboro, TN 37129 12/04/2019
FINAL BID DOCUMENTS
626A4-18-20318-028
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
Scale: 1/8" = 1'-0"
ROOF PLAN
1 ADDENDUM 1 05/06/2020
A-702
11'-1 1/2"
23'-0"
10'-2"
MACHINE ROOM
PLATFORM
EL: 41'-5"
PENTHOUSE
EL: 37'-2"
PENTHOUSE
MACHINE
ROOM
NEW MACHINE FOR
ELEVATOR, REFER TO
ELEVATOR
SPECIFICATIONS FOR
SIZE AND LOCATION
P9
FEC
NEW WALL
EXISTING WALL
DEMO. WALL
A
LA
R
E GI H,NC
S
G O 52644
P E
N
CO
LU IT
E
NG
RG
U O
A
P ,P
R E
G I
S T
E R
E D
A R
C H I T E C T U R
A L
C O
R P
O T
I O
N
N O
R T H C A R O L
I N
A
A R
LA
R
E GI H, N
C
N
11664
I K
G HC OY
R
EG
IS
TE
RED ARCH
ITEC
T
N O R
T H
CA RO
L
I N A
# KEY NOTES:
Revisions: Date
Drawing Title:
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER:
SHEET NOTES:
WALL RATING LEGEND
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs#
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREAS S S S
/6
/2
:4
:5
P M
A-107
ATTIC PLAN - BUILDING 9
10 19KC HM
Architectural and Engineering Services to Upgrade Elevators
Buildings 8, 9 and 10
Alvin C. York VA Medical Center 3400 Labanon Pike
Murfeesboro, TN 37129 12/04/2019
FINAL BID DOCUMENTS
626A4-18-20318-028
N
AREA OF WORK
SCOPE OUTLINE
KEY PLAN
SCALE: NO SCALE
Scale: 1/8" = 1'-0"
ROOF PLAN 0 4 8 16
N O
R T
H
TRUE
WALL LEGEND
1 ADDENDUM 1 05/06/2020
MACHINE
ROOM
7 10
GROUND FLOOR
EL: 0'-0"
FIRST FLOOR
EL: 11'-11"
SECOND FLOOR
EL: 23'-10"
ATTIC
EL: 37'-2"
T.O. ELEVATOR PIT
EL: -4'-3"
A-701
A-701
A-701
SUMP
PUMP
CORRIDOR
G28
OFFICE
G02
CORRIDOR
DINING
CORRIDOR
252DINING
PENTHOUSE
AT ATTIC
HOIST BEAM, REFER
TO STRUCTURAL
FOR DETAIL
REFER TO CIVIL AND
STRUCTURAL FOR
ADDITIONAL DETAILS
ELEVATOR PIT,
REFER TO
STRUCTURAL
ELEVATOR
MACHINE
ROOM
GROUND FLOOR
EL: 0'-0"
ELEVATOR PIT
EL: -4'-3"
REFER TO A-701/5
FOR LADDER
DETAILS
SELF ADHERED
NON-PERMEABLE
MEMBRANE,
TURN DOWN AT
FOOTING
RIGID INSULATION
CAPILLARY FILL
CONCRETE SLAB
ON GRADE,
SEE STRUCTURAL
8X8X16 CMU GROUT
SOLID, TYP.
ELEVATOR
PIT, REFER
TO
STRUCTURAL
ELEVATOR
SHAFT
FIRST FLOOR
EL: 11'-11"
8"X8"X16" CMU BLOCK LINTEL
5/8" GYP BOARD
3 5/8" METAL STUDS @ 16" OC
FINISHED CEILING, REFER TO
FINISH SCHEDULE
CORNER GUARD
ELEVATOR SLIDING DOOR
FINISH FLOOR
EXISTING FLOOR
8X8X16 CMU GROUT SOLID, TYP.
ATTIC
EL: 37'-2"
8"X8"X16" CMU BLOCK LINTEL
3 5/8" METAL STUDS @ 16" OC
CORNER GUARD
EXISTING COLUMN
ELEVATOR DOOR
CEILING, REFER TO SCHEDULE
HOIST BEAM, REFER TO
STRUCTURAL FOR DENTALS
8X8X16 CMU GROUT SOLID,
TYP.
CEILING ASSEMBLY
RESTRAINED
ASSEMBLY RATING
2HR, DESIGN NO.
P836, ANSI/UL 263
I
3 5/8" METAL STUDS @ 16" OC
5/8" GYP BOARD
B
B
3 5/8" METAL STUDS @ 16" OC
CG-1
EXISTING COLUMN 1 1/2" METAL STUDS @ 16" OC
1 1/2"" METAL STUDS @ 16" OC
ELEVATOR
SLIDING
DOOR
NEW ELEVATOR
/2
CG-1
8X8X16 CMU
GROUT SOLID, TYP.
1/2" E.J. AT COLUMN
1/2" E.J. AT COLUMN
I
EXISTING WALL
EXISTING WALL
D
V.I.F.
8"
EXISTING
COLUMN
V .I .F
8X8X16 CMU
GROUT SOLID,
TYP.
J
3 5/8" METAL STUDS @ 16" OC
B
B
B
BA
CG-1
W-1
EXISTING COLUMN
5/8" GYP BOARD
V.I.F.
1'-2"
V.I.F.
8"
/2
7 1/2"
V.I.F.
6"
V.I.F.
1'-4 1/2"
CG-1CG-1
CG-1
1/2" E.J. AROUND
COLUMN, TYP.
I
D
B
B
3 5/8" METAL STUDS @ 16" OC
CG-1
F
ELEVATOR
SLIDING
DOOR
NEW
ELEVATOR
5/8" GYP BOARD
3 5/8" METAL STUDS @ 16" OC
1 1/2"" METAL STUDS @ 16" OC
EXISTING WALL
EXISTING COLUMN
3 5/8" METAL STUDS @ 16" OC
/2
/2
1'-2"
11 1/2"
V .I
.F
/2
V.I.F.
11 1/2"
S E
E D
O O
R S
C H
E D
U L
E
R O
U G
H O
P E
N
IN
G
CG-1
8X8X16 CMU GROUT
SOLID, TYP.
1/2" E.J. AT COLUMN
1/2" E.J.
AT
COLUMN
I
EXISTING WALL
EXISTING
COLUMN
D
D
B
B
5/8" GYP BOARD
3 5/8" METAL STUDS @ 16" OC
CG-1
3 5/8" METAL STUDS @ 16" OC
ELEVATOR
V.I.F.
10"
7"
8X8X16 CMU GROUT SOLID, TYP.
FINISH FLOOR AT
ELEVATOR PIT
2-1/2" X 1/4" STEEL
BAR STRINGER
3/4" STEEL
RUNGS WELD TO
STRINGER
1/2: CONCRETE
ANCHOR
EXTEND LADDER 5'-0"
ABOVE BASEMENT
(GROUND) LEVEL'S
FLOOR SILL
ENTRANCE
ELEVATOR MANUFACTURER
CLEARANCE
REQUIREMENTS. VERIFY
REQUIRED OSHA TOE
CLEARANCE.
GROUND FLOOR
EL: 0'-0"
1'-6"
1'-6"
T Y
P
/2
A .F
.F
CL
6"
ROOF
EL: 56'-10"
NEW MACHINE FOR
ELEVATOR, REFER TO
ELEVATOR SPECIFICATIONS
FOR SIZE AND LOCATION
A
LA
R
E GI H,NC
S
G O 52644
P E
N
CO
LU IT
E
NG
RG
U O
A
P ,P
R E
G I
S T
E R
E D
A R
C H I T E C T U R
A L
C O
R P
O T
I O
N
N O
R T H C A R O L
I N
A
A R
LA
R
E GI H, N
C
N
11664
I K
G HC OY
R
EG
IS
TE
RED ARCH
ITEC
T
N O R
T H
CA RO
L
I N A
# KEY NOTES:
Revisions: Date
Drawing Title:
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER:
SHEET NOTES:
WALL RATING LEGEND
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs#
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREAS S S S
/6
/2
:2
:5
P M
A-701
VERTICAL CIRCULATION PLANS,
SECTIONS AND DETAILS - BUILDING 8
17 19KC HM
Architectural and Engineering Services to Upgrade Elevators
Buildings 8, 9 and 10
Alvin C. York VA Medical Center 3400 Labanon Pike
Murfeesboro, TN 37129 12/04/2019
FINAL BID DOCUMENTS
626A4-18-20318-028
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
Scale: 3/8" = 1'-0"
SECTION THROUGH ELEVATOR SHAFT
Scale: 3/4" = 1'-0"
SECTION THROUGH ELEVATOR SHAFT
Scale: 3/4" = 1'-0"
SECTION THROUGH ELEVATOR SHAFT
Scale: 3/4" = 1'-0"
SECTION THROUGH ELEVATOR SHAFT
Scale: 1 1/2" = 1'-0"
PLAN DETAIL
Scale: 1 1/2" = 1'-0"
PLAN DETAIL
Scale: 1 1/2" = 1'-0"
PLAN DETAIL
Scale: 1 1/2" = 1'-0"
PLAN DETAIL
Scale: 1 1/2" = 1'-0"
PLAN DETAIL
Scale: 1" = 1'-0"
LADDER DETAIL
A. REFER TO STRUCTURAL DRAWINGS FOR DETAILS
ON STRUCTURAL ELEMENTS.
B. REFER TO ELEVATOR SPECIFICATIONS FOR
INFORMATION ON ELEVATORS AND ELEVATOR
EQUIPMENT.
C. ELEVATOR SHAFTS CONSIST OF 8” CMU WALL AND
CAST-IN-PLACE CONCRETE FOUNDATION PIT.
D. REFER TO ASBESTOS ASSESSMENT REPORT FOR
MORE DETAILED INFORMATION REGARDING
ASBESTOS CONTAINING MATERIAL OR ASBESTOS
CONTAMINATED ELEMENTS PRESENT IN THIS
BUILDING. ASBESTOS REPORT PREFORMED BY
ENVIRONMENTAL HEALTH MANAGEMENT IN
NOVEMBER 2004.
1 ADDENDUM 1 05/06/2020
15 18
A-702
A-702
A-702
CONFERENCE
LOBBY
G01A
LOBBY
HAC
G03
LOBBY
PHYCOLOGY
ATTIC AT
PENTHOUSE
- PENTHOUSE
ELEVATOR
MACHINE
ROOM
GROUND FLOOR
EL: 0'-0"
FIRST FLOOR
EL: 11'-11"
SECOND FLOOR
EL: 23'-10"
ATTIC
EL: 37'-2"
T.O. ELEVATOR PIT
EL: -4'-3"
T.O. EXISTING FOOTING
EL: -8'-6"
B9-G2
ELEVATOR
B9-12
ELEVATOR
B9-22
ELEVATOR
NEW MACHINE FOR ELEVATOR,
REFER TO ELEVATOR
SPECIFICATIONS FOR SIZE
AND LOCATION
PENTHOUSE
GYPSUM WALL
BOARD SOFFIT,
PNT-8
6" 1'-6" 6"
SUMP
PUMP
EXISITNG
FOOTING
EXISITNG
FOOTING
ELEVATOR PIT PLATFORM,
REFER TO STRUCTURAL
HOIST BEAM, REFER
TO STRUCTURAL
FOR DETAIL
/2
3 5/8" METAL STUDS @ 16" OC
5/8" GYP BOARD
8"X8"X16" CMU BLOCK LINTEL
8"X8"X16" CMU BLOCK
3 5/8" METAL STUDS @ 16" OC
FINISHED CEILING,
REFER TO FINISH
SCHEDULE
ELEVATOR
SHAFT
ELEVATOR SLIDING DOOR
EXISTING BEAM,
REFER TO
STRUCTURAL
FINISH FLOOR AT
ELEVATOR PIT
2-1/2" X 1/4" STEEL
BAR STRINGER
3/4" STEEL
RUNGS WELD TO
STRINGER
1/2: CONCRETE
ANCHOR
EXTEND LADDER 5'-0"
ABOVE BASEMENT
(GROUND) LEVEL'S
FLOOR SILL
ENTRANCE
ELEVATOR MANUFACTURER
CLEARANCE
REQUIREMENTS. VERIFY
REQUIRED OSHA TOE
CLEARANCE.
GROUND FLOOR
EL: 0'-0"
1'-6"
1'-6"
T Y
P
/8
A .F
.F
CL
6"
REFER TO
LADDER DETAIL
FOR MORE
INFORMATION
RIGID INSULATION
CAPILLARY FILL
8"X8"X16" CMU
GROUT SOLID
CONCRETE
SLAB ON
GRADE, SEE
STRUCTURAL
EXISTING COLUMN
EXISTING FOOTING
SELF ADHERED NON-
PERMEABLE
MEMBRANE, TURN
DOWN AT FOOTING
8"X6"X16" CMU BLOCK
GROUT SOLID, TYP.
8"X8"X16" CMU BLOCK
8"X8"X16" CMU BLOCK LINTEL
ELEVATOR SLIDING
DOOR
FINISHED CEILING,
REFER TO FINISH
SCHEDULE
ELEVATOR
SHAFT
3 5/8" METAL STUDS @ 16" OC
5/8" GYP BOARD
/2
2-1/2 METAL STUDS @ 16"
OC, PNT-9
ACT-1
PNT-1
CEILING ASSEMBLY
RESTRAINED ASSEMBLY
RATING 2HR, DESIGN NO.
P836, ANSI/UL 263
I
11 1/4" 2'-0 1/4"
V.I.F.
1'-4 3/4"
EXISTING WALL
EXISTING
COLUMN
5/8"
GYPSUM
BOARD
C
D
3 5/8" METAL STUDS @ 16" OC
EXPANSION
JOINT
8X8X16 CMU
BLOCK GROUT
SOLID
8X8X16 CMU
BLOCK
GROUT
SOLID
8" CMU BLOCK
8" CMU BLOCK
5/8" GYPSUM BOARD
/4
V.I.F.
1'-4 3/4"
V.I.F.
7 1/4"
C
C
A
3 5/8" METAL STUDS @ 16" OC
3 5/8" METAL STUDS @ 16" OC
EXISTING DOOR
FRAME
3 5/8" METAL STUDS @ 16" OC
EXISTING
COLUMN
EXISTING PARTITION
CG-1
EXISTING ACT
8' - 0"
GYP
9' - 0"
ACT
2x2
COUNTER WITH
COUNTER
BRACKET
TRANSACTION
SLIDING WINDOW,
REFER TO SHEET
A-601 FOR
ADDITIONAL
INFORMATION..
W-2
A-702
PATIENT'S SIDE
CLERK'S SIDE
6"1'-9"
PLY WOOD, WITH HIGH
PRESSURE LAMINATE
PL-1
RB-1
S-1S-1
RB-1
PNT-1
GYP, PNT-9
ACT-1
PNT-1
3 5/8" METAL STUDS
@16" OC WITH 5/8"
GYPSUM BOARD
2 1/2" METAL STUDS
@16" OC
CONCEALED WALL
MOUNT SUPPORT
BRACKET - SPACE AT
4'-0" MAX. INSTALL
AND PROVIDE
BLOCKING PER
MANUFACTURER'S
RECOMMENDATIONS.
1" X 4" CONT. WOOD
BLOCKING (TYP.)
EXISTING
CEILING SLAB
ABOVE
SLIDING GLASS FRAME
WALL AS SCHEDULED
SILLCLERK COUNTER
SOLID SURFACE COUNTER, S-1
SOLID SURFACE
COUNTER, S-1
WOOD BLOCKING
PLYWOOD, L-1
6"
COUNTER BRACKET
A
LA
R
E GI H,NC
S
G O 52644
P E
N
CO
LU IT
E
NG
RG
U O
A
P ,P
R E
G I
S T
E R
E D
A R
C H I T E C T U R
A L
C O
R P
O T
I O
N
N O
R T H C A R O L
I N
A
A R
LA
R
E GI H, N
C
N
11664
I K
G HC OY
R
EG
IS
TE
RED ARCH
ITEC
T
N O R
T H
CA RO
L
I N A
Revisions: Date
Drawing Title:
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER:
SHEET NOTES:
WALL RATING LEGEND
E
D C
B A
2 3 4 5 6 7
E D
C B
A
1 2 3 4 5 6 7
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs#
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREAS S S S
/6
/2
:4
:0
P M
A-702
VERTICAL CIRCULATION PLANS,
SECTIONS AND DETAILS - BUILDING 9
18 19KC HM
Architectural and Engineering Services to Upgrade Elevators
Buildings 8, 9 and 10
Alvin C. York VA Medical Center 3400 Labanon Pike
Murfeesboro, TN 37129 12/04/2019
FINAL BID DOCUMENTS
626A4-18-20318-028
N
AREA OF WORK
SCOPE OUTLINE
KEY PLAN
SCALE: NO SCALE
Scale: 3/8" = 1'-0"
BUILDING SECTION THROUGH NEW ELEVATOR SHAFT
Scale: 3/4" = 1'-0"
SECTION THROUGH ELEVATOR SHAFT
Scale: 1" = 1'-0"
LADDER DETAIL
Scale: 3/4" = 1'-0"
SECTION THROUGH ELEVATOR SHAFT
Scale: 3/4" = 1'-0"
SECTION THROUGH ELEVATOR SHAFT
Scale: 1 1/2" = 1'-0"
PLAN DETAIL
Scale: 1 1/2" = 1'-0"
PLAN DETAIL
Scale: 1 1/2" = 1'-0"
PLAN DETAIL
A. REFER TO STRUCTURAL DRAWINGS FOR DETAILS
ON STRUCTURAL ELEMENTS.
B. REFER TO ELEVATOR SPECIFICATIONS FOR
INFORMATION ON ELEVATORS AND ELEVATOR
EQUIPMENT.
C. ELEVATOR SHAFTS CONSIST OF 8” CMU WALL AND
CAST-IN-PLACE CONCRETE FOUNDATION PIT.
D. REFER TO SHEET A-601 FOR ADDITIONAL
INFORMATION ON DOORS AND WINDOWS.
E. REFER TO ASBESTOS ASSESSMENT REPORT FOR
MORE DETAILED INFORMATION REGARDING
ASBESTOS CONTAINING MATERIAL OR ASBESTOS
CONTAMINATED ELEMENTS PRESENT IN THIS
BUILDING. ASBESTOS REPORT PREFORMED BY
ENVIRONMENTAL HEALTH MANAGEMENT IN
NOVEMBER 2004.
Scale: 3/4" = 1'-0"
SECTION THROUGH SLIDING TRANSACTION WINDOW
Scale: 1 1/2" = 1'-0"
SILL AT TRANSACTION COUNTER
1 ADDENDUM 1 05/06/2020
| Sheets |
| G-001 - COVER SHEET |
| A-103 - ROOF PLAN AT PENTHOUSE - BUILDING 8 |
| A-701 - VERTICAL CIRCULATION PLANS, SECTIONS AND DETAILS - BUILDING 8 |
| 2020-05-06T12:12:53-0700 | |
| Digitally verifiable PDF exported from www.docusign.com |