H8227090 VA Hospital - CLC 1st and 2nd Floor - Asbestos and Lead Report.pdf

PDF 6 MB Posted

Attached to
Renovate Community Living Center (CLC) - 1st & 2nd Floor
Solicitation number
36C24825R0033
Issued by

About this file

This is a pre-renovation asbestos and lead paint survey report conducted by Terracon Consultants for the VA Hospital CLC 1st and 2nd Floors in Miami, Florida, dated February 16, 2023. The survey was requested by RDC/John Poe Architects due to planned renovations of the Community Living Center floors.

The survey found asbestos present in three building materials: black mastic (3% Chrysotile) associated with white/brown striped vinyl floor tiles covering approximately 22,641 square feet on both floors; black mastic (3% Chrysotile) associated with grey ceramic floor tiles covering 260 square feet in the 1st floor vending area and room 111B; and black mastic (3% Chrysotile) associated with off-white/brown striped vinyl floor tiles covering 960 square feet in several 2nd floor rooms. All asbestos-containing materials were categorized as Non-Friable Category I ACM under NESHAP regulations. Lead paint testing of seven samples from various surfaces showed no detectable lead content (all results below 40 ppm). The report includes detailed sampling locations, laboratory analysis results, regulatory requirements, and recommendations for handling the asbestos-containing materials during renovation activities.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Facilities | Environmental | Geotechnical | Materials I

Pre-Renovation Asbestos Survey and Lead Paint Report VA Hospital – CLC 1st and 2nd Floors

February 16, 2023 | Report Number: H8227090

5371 NW 33rd Avenue, Suite 201 Fort Lauderdale, Florida 33309 P (954) 741-8282

5371 NW 33rd Avenue, Ste 201 Ft. Lauderdale, FL 33309

P: (954) 741-8282

Terracon.com

Facilities | Environmental | Geotechnical | Materials I

February 16, 2023

RDC/John Poe Architects, LLLP 116 East 3rd Street Dayton, Ohio 45402-2130

Attn: Mr. Jason Ross P 800.362.1523 E jross@rdcjohnpoe.com

RE: Pre-Renovation Asbestos Survey and Lead Paint Report VA Hospital – CLC 1st and 2nd Floors 1201 NW 16th Street Miami, Florida Terracon Project No. H8227090

Dear Mr. Ross, Terracon Consultants, Inc. (Terracon) is pleased to submit the attached report to RDC/John Poe Architects, LLLP. The purpose of this report is to present the results of a pre-renovation asbestos and lead paint survey performed on February 1 and 2, 2023, at the above referenced location in Miami, Florida. This survey was conducted in general accordance with Terracon Proposal number PH8227090, dated June 10, 2022. We understand that this survey was requested due to the planned renovation of the CLC 1st and 2nd Floors within the structure.

Based on the laboratory results, asbestos was detected in building materials assessed during our survey assessment. Please refer to the attached report for details.

Lead containing paint was not detected in the laboratory reporting in samples taken during our survey assessment. Please refer to the attached report for details.

Terracon appreciates the opportunity to provide this service to RDC/John Poe Architects, LLLP. If you have any questions regarding this report, please contact us at (954) 741-8282.

Sincerely, Terracon Consultants, Inc.

Florida Asbestos Consulting Business License No. ZA337

Sergio A. Adasme

Project Industrial Hygienist

Brian J. DuChene, PE

Licensed Asbestos Consultants EA75 https://na3.documents.adobe.com/verifier?tx=CBJCHBCAABAA3r_VGUleGmwFsIBo-4Ffn7fjldZF8jYN

Facilities | Environmental | Geotechnical | Materials i

TABLE OF CONTENTS

Page

1.0 Introduction

1.1 Project Objective

1.2 Reliance

2.0 Building Description

3.0 Field Activities

3.1 Asbestos

3.2 Lead Containing Paint

4.0 Regulatory Overview

4.1 Asbestos

4.2 Lead in Construction

5.0 Findings and Recommendations

5.1 Asbestos

5.2 Lead containing paint

6.0 General Comments

Appendices

Appendix A Asbestos Sample Location Summary

Appendix B Asbestos Analytical Laboratory Data

Appendix C LCP Analytical Laboratory Data

Appendix D Licenses and Certifications

Appendix E Sample Location Diagram

Appendix F Photographs

Pre-Renovation Asbestos and Lead Paint Survey Report VA Hospital – CLC 1st and 2nd Floors | Miami, Florida

February 16, 2023 | Terracon Report No. H8227090

Facilities | Environmental | Geotechnical | Materials 1

1.0 Introduction

Terracon Consultants, Inc. (Terracon) conducted a Pre-Renovation asbestos and lead paint survey in the CLC 1st and 2nd Floors within the building located at 1201 NW 16th Street Miami, Florida.

The survey was conducted on February 1 and 2, 2023, by Asbestos Hazard Emergency Response Act (AHERA)-accredited asbestos inspectors working under the direction of a Florida Licensed Asbestos Consultant (FLAC) in general accordance with a Terracon proposal PH8227090, dated June 10, 2022. The structure’s components, as designated by the site representative, were surveyed and homogeneous areas of suspect asbestos-containing materials (ACM) were visually identified and documented. Additionally, Terracon obtained readily and safely accessible paint-chip samples from surfaces of the renovation areas to identify the presence and concentration of lead paint. Although reasonable effort was made to survey accessible suspect materials, additional suspect but un-sampled materials could be located in walls, in voids or in other concealed areas.

Suspect ACM samples were collected in general accordance with the sampling protocols outlined in EPA regulation 40 CFR 763 (AHERA). Asbestos samples were delivered to an accredited laboratory for analysis. Suspect ACM samples were analyzed by Polarized Light Microscopy.

Suspect lead containing paint samples were obtained from representative surfaces potentially containing lead paint coatings. Lead paint samples were delivered to an accredited laboratory for analysis by Flame Atomic Absorption Spectrophotometry (EPA method SW846 7000B).

1.1 Project Objective

We understand this hazardous material survey was requested due to the planned future renovation of the CLC 1st and 2nd Floors within the structure. EPA regulation 40 CFR 61, Subpart M, National Emission Standards for Hazardous Air Pollutants (NESHAP), prohibits the release of asbestos fibers to the atmosphere during renovation or demolition activities. The asbestos NESHAP requires that potentially regulated ACM (RACM) be identified, classified, and quantified prior to planned renovation or demolition activities.

In addition, suspect lead containing paint (LCP) samples were obtained to identify potential exposure sources, regulated by the Occupational Safety and Health Administration (OSHA) 29 CFR

1926.62 and other applicable EPA regulations that could develop if coatings are disturbed during planned renovation or demolition activities.

1.2 Reliance

This report is for the exclusive use of RDC/John Poe Architects, LLLP for the project being discussed. Reliance by any other party on this report is prohibited without written authorization of Terracon and RDC/John Poe Architects, LLLP. Reliance on this report by RDC/John Poe Architects, LLLP and all authorized parties will be subject to the terms, conditions, and limitations stated in the proposal, this report and the existing agreement between RDC/John Poe Architects, LLLP and Terracon. The limitations of liability defined in Terracon’s Agreement for Services is the aggregate limit of Terracon’s liability to RDC/John Poe Architects, LLLP.

February 16, 2023 | Terracon Report No. H8227090

Facilities | Environmental | Geotechnical | Materials 2

2.0 Building Description

The four-story building construction date is unknown. The building materials consisted of a stucco and stone exterior walls atop a concrete slab. Interior finishes the CLC 1st and 2nd Floors consisted of lay-in ceiling tiles, drywall systems with vinyl floors, ceramic floor tiles and ceramic wall tiles.

3.0 Field Activities

The survey was conducted by AHERA-accredited asbestos inspectors, Mr. Ryan Nanan. The survey was conducted in general accordance with the sample collection protocols established in EPA regulation 40 CFR 763 (AHERA). Paint chip sampling for lead was conducted on observed painted surfaces located within the surveyed areas. Copies of the applicable licenses and certifications are included in Appendix C. Asbestos analytical laboratory data is included as Appendix A. Lead containing paint analytical laboratory data is included as Appendix B.

3.1 Asbestos

Our survey activities began with visual observations of accessible interior areas to identify homogeneous areas of suspect ACM. A homogeneous area consists of building materials that appear similar throughout in terms of color, texture, and date of application. The assessment was conducted throughout visually accessible areas of the CLC 1st and 2nd Floors within the building.

Materials identified as glass, wood, metal, or rubber were not considered suspect ACM.

A physical assessment of each homogeneous area of suspect ACM was conducted to assess the friability and condition of the materials. A friable material is defined by the EPA as a material which can be crumbled, pulverized, or reduced to powder by hand pressure when dry. Friability was assessed by physically touching suspect materials.

Based on results of the visual observation, bulk samples of suspect ACM were collected in general accordance with AHERA sampling protocols. Random samples of suspect materials were collected in each homogeneous area. Samples were collected bulk samples using wet methods as applicable to reduce the potential for fiber release. Samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker.

A total of 128 bulk samples were collected from 29 homogeneous areas of suspect ACM during the survey completed on February 1 and 2, 2023. An asbestos sample location summary is included as Appendix A.

Bulk samples were submitted under chain of custody to Eurofins EPK Built Environment Testing, LLC (Eurofins EPK) in Orlando, Florida for analysis by PLM per EPA methodology EPA/600/R- 93/116. The percentage of asbestos, where applicable, was determined by microscopic visual estimation. Eurofins EPK is accredited under the National Voluntary Laboratory Accreditation Program (NVLAP Accreditation No. 600274-0).

February 16, 2023 | Terracon Report No. H8227090

Facilities | Environmental | Geotechnical | Materials 3

3.2 Lead Containing Paint

Terracon performed a visual assessment of the interior of the CLC 1st and 2nd Floors within the structure to identify, locate and assess predominant painted surfaces for lead. Representative paint chip samples were chosen from each unique combination of paint color, component, and substrate.

A total of 7 paint chips samples were collected and submitted to Eurofins EPK of Tustin, California for analysis. The paint chips were analyzed by Flame Atomic Absorption Spectrometry (AAS) by NIOSH 7082 and EPA method 7000B Modified. Eurofins EPK is accredited under the Environmental Lead Laboratory Accreditation Program (AIHA-LAP, Accreditation No. 178697). Analytical laboratory data for LCP samples taken during this survey are provided in Appendix C.

4.0 Regulatory Overview

4.1 Asbestos

The asbestos NESHAP (40 CFR Part 61, Subpart M) regulates asbestos fiber emissions and asbestos waste disposal practices. It also requires the identification and classification of existing materials prior to demolition or renovation activity. Under NESHAP, ACM are classified as either friable, Category I non-friable or Category II non-friable ACM. Friable materials are those that, when dry, may be crumbled, pulverized, or reduced to powder by hand pressure. Category I non-friable ACM includes packings, gaskets, resilient floor coverings and asphalt roofing products containing more than 1% asbestos. Category II non-friable ACM are any non-friable materials other than non-friable Category I materials that contain more than 1% asbestos.

Friable ACM, Category I and Category II non-friable ACM which is in poor condition and has become friable or which will be subjected to drilling, sanding, grinding, cutting, or abrading and which could be crushed or pulverized during anticipated renovation or demolition activities are considered RACM.

The NESHAP regulations include an option for Friable materials or potential RACM that are found to contain less than 10% asbestos to be “point-counted” or analyzed by similar, advanced analytical methods, such as Transmission Electron Microscopy (TEM), to confirm the asbestos concentrations. If the additional “point-counting” or TEM analysis is not implemented then the materials are required to be categorized as ACM (>1% asbestos content) even if the initial, estimated laboratory results are reported “trace” or less than 1% (<1%) asbestos content.

In the State of Florida, asbestos activities are regulated by the Florida Department of Environmental Protection (FDEP), which is enforced locally by the Miami-County Division of Environmental Resources Management, which is located at 701 NW 1st Court, Suite 400 Miami, FL 33324. RACM must be removed prior to renovation or demolition activities which will disturb the materials. The owner or operator must provide the FDEP with written notification of planned removal activities at least 10 working days prior to the commencement of asbestos abatement activities. Removal of ACM and/or RACM must be conducted by a State of Florida-licensed asbestos abatement contractor.

February 16, 2023 | Terracon Report No. H8227090

Facilities | Environmental | Geotechnical | Materials 4

The OSHA Asbestos standard for construction (29 CFR 1926.1101) regulates workplace exposure to asbestos. The OSHA standard requires that employee exposure to airborne asbestos fibers be maintained below 0.1 asbestos fibers per cubic centimeter of air (0.1 f/cc) for an 8-hour time-weighted average (TWA) permissible exposure limit (PEL) and 1.0 f/cc over a 30-minute period for an excursion limit (EL).

The OSHA standard classifies construction and maintenance activities which could disturb ACM and specifies work practices and precautions which employers must follow when engaging in each class of regulated work. In addition, OSHA requires that activities where workers disturb materials with even “trace” amounts of asbestos content (<1%) are still regulated and require compliance with certain elements of the regulation.

4.2 Lead in Construction

Lead is regulated by the EPA, HUD, FDEP and OSHA. The EPA and FDEP regulate lead use, removal, and disposal, and OSHA regulates lead exposure to workers. The EPA and HUD, with their small child-safety focus, define Lead-Based Paint (LBP) as paint, varnish, stain, or other applied coating that contains lead equal to or greater than 1.0 mg/cm2, 5,000 mg/kg, or 0.5% by dry weight as determined by laboratory analysis.

However, for the purpose of the OSHA lead standard, with its focus on the safety/exposure of construction workers, paint-containing lead includes any detectable concentrations of metallic lead, all inorganic lead compounds, and organic lead soaps. A synopsis of the OSHA regulations (29 CFR 1926.62) and the applicability are as follows:

The OSHA Lead Standard for Construction (29 CFR 1926.62) applies to all construction work where an employee may be occupationally exposed to lead. All work related to construction, alteration, or repair (including painting and decorating) is included. The lead-in-construction standard applies to any detectable concentration of lead in paint, as even small concentrations of lead can result in unacceptable employee exposures depending upon on the method of removal and other workplace conditions. The OSHA standard requires employee exposure to airborne lead to be maintained below the PEL of 50 micrograms per cubic meter of air (ug/m3) over an 8-hour

TWA.

Under this standard, construction includes, but is not limited to, the following:

Demolition or salvage of structures where lead or materials containing lead are present

Removal or encapsulation of materials containing lead

New construction, alteration, repair, or renovation of structures, substrates, or portions containing lead, or materials containing lead

Installation of products containing lead

Lead contamination/emergency clean-up

Transportation, disposal, storage, or containment of lead or materials containing lead on the site or location at which construction activities are performed

Maintenance operations associated with construction activities described above

February 16, 2023 | Terracon Report No. H8227090

Facilities | Environmental | Geotechnical | Materials 5

5.0 Findings and Recommendations

5.1 Asbestos

Black mastic (3% Chrysotile) associated with the non-asbestos White with Brown Strips 12’’x12’’ Vinyl Floor Tiles (HA-8) the material measures approximately 22,641 square feet combine on the 1st and 2nd CLC floors and is located in all the CLC 1st floor patient rooms and south hallway in outskirt of CLC 1st floor and CLC 2nd floor patient rooms 221A, 223, 224, 225, 226, 227, 228, 229, 230, 231, 232, 233, 238, 241,242, 243,244, 245, 246, 247, 248, 249, 250, 251, 252, 253, 254, 255, 256, 258, 259 and south hallway in outskirt of CLC 2nd floor. This quantity is an estimate of visual material. The material, in its current condition, is categorized under the NESHAP as a Non-Friable, Category I ACM.

Black mastic (3% Chrysotile) associated with the non-asbestos Grey 5’’x5’’ Ceramic Floor Tile and Thinset (HA-24) the material measures approximately 260 square feet and is located on the CLC 1st floor vending machine area and room 111B. The material, in its current condition, is categorized under the NESHAP as a Non-Friable, Category I ACM.

Black mastic (3% Chrysotile) associated with the non-asbestos Off White with Brown Strips 12’’x12’’ Vinyl Floor Tiles (HA-28) the material measures approximately 960 square feet and is located on the CLC 2nd floor rooms 222, 257 261 and 263A. The material, in its current condition, is categorized under the NESHAP as a Non-Friable, Category I ACM

The results of this assessment should be communicated to the renovation contractor and other subcontractors working in the building and a copy of the survey should be on-site during renovation or demolition activities. In addition, a 10-day renovation/demolition notice will need to be sent to Miami-Dade County, Division of Environmental Resources Management. We recommend a call be made to (305) 372-6925 to confirm their regulatory requirements.

Any concealed building materials discovered during renovation activities not identified in this report, which are suspected to contain asbestos, should be sampled by a Florida Licensed Asbestos Consultant and analyzed by a NVLAP-accredited laboratory to confirm the presence or absence of asbestos prior to disturbing such materials. If the materials are found to contain asbestos, various regulations (EPA NESHAP, FDEP and OSHA) will apply. In addition, direct contact with the FDEP is recommended to confirm their actual regulatory requirements.

February 16, 2023 | Terracon Report No. H8227090

Facilities | Environmental | Geotechnical | Materials 6

5.2 Lead containing paint

No Lead containing paint was not detected in the samples collected during this site inspection.

Sample

Description Substrate Lead

Results (ppm)

L1 Light Green – CLC 1st Floor Drywall and Joint Compound

Walls < 40 ppm

L2 Light Brown - CLC 1st Floor Metal Door Frame < 40 ppm

L3 Light Blue - CLC 1st Floor Drywall and Joint Compound

Walls < 40 ppm

L4 Light Brown - CLC 1st Floor Metal Door < 39 ppm

L5 Light Blue - CLC 2nd Floor Drywall and Joint Compound

Walls < 39 ppm

L6 Light Brown - CLC 2nd Floor Metal Door Frame < 40 ppm

L7 White - CLC 2nd Floor Drywall and Joint Compound

Walls < 39 ppm

Any concealed building painted surfaces discovered during renovation activities not identified in this report which are suspected to contain lead, should be sampled, and analyzed.

The results of this assessment should be communicated to the renovation contractor and other subcontractors working in the building and a copy of the survey should be on-site during the renovation activities.

February 16, 2023 | Terracon Report No. H8227090

Facilities | Environmental | Geotechnical | Materials 7

6.0 General Comments

It should be noted that suspect asbestos materials other than those identified during our survey may exist in locations outside of the designated surveyed areas. Should suspect materials other than those which were identified during this survey be uncovered prior to renovation activities, those materials should be assumed asbestos-containing, until sampling and analysis can confirm or deny their asbestos content.

Suspect LCP, other than those identified during the sampling, may be present in the building. This LCP testing is not considered comprehensive in nature and the results are not intended to be used to determine lead hazards, develop abatement plans, or prepare detailed cost estimates for abatement.

Suspect LCP which has not been specifically evaluated should be tested prior to disturbance of the material. If additional suspect LCP is identified during the demolition process, those materials should be assumed LCP until testing can be performed to determine whether lead is present in the paint.

The asbestos and LCP survey was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, conclusions, and recommendations expressed in this report are based on conditions observed during our survey of the building. The information contained in this report is relevant to the date on which this survey was performed and should not be relied upon to represent conditions later.

This report has been prepared on behalf of and exclusively for use by the Client. for specific application to their project as discussed. This report is not a bidding document. Contractors or consultants reviewing this report must draw their own conclusions regarding further investigation or remediation deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories or other third parties supplying information which may have been used in the preparation of this report. No warranty, express or implied is made.

Facilities | Environmental | Geotechnical | Materials

Appendix A

Asbestos Sample Location Summary

February 16, 2023 | Terracon Report No. H8227090

Facilities | Environmental | Geotechnical | Materials 1

HA

Number

Sample Number

Material Description Material Location Lab Results

HA1

1A

White 2’x2’ Worm Ceiling Tile

W side of CLC 1st Floor

ND

1B Center of CLC 1st Floor 1C E side of CLC 1st Floor 1D S side of CLC 1st Floor 1E S side of CLC 2nd Floor 1F W side of CLC 2nd Floor 1G E side of CLC 2nd Floor

HA2

2A

Drywall and Joint Compound Ceiling

N side of CLC 1st Floor

ND

2B E side of CLC 1st Floor 2C N side of CLC 1st Floor 2D Center of CLC 1st Floor 2E N side of CLC 2nd Floor 2F W side of CLC 2nd Floor 2G E side of CLC 2nd Floor

HA3

3A

Pink Fiber Glass Reinforced Panel and Brown Glue

N side of CLC 1st Floor

ND

3B Center of CLC 1st Floor 3C E side of CLC 1st Floor 3D W side of CLC 2nd Floor 3E NE side of CLC 2nd Floor

HA4

4A

Brown Wall Panel and Brown Glue

N side of CLC 1st Floor

ND

4B S side of CLC 1st Floor 4C E side of CLC 1st Floor 4D SW side of CLC 2nd Floor 4E S side of CLC 2nd Floor

HA5

5A

Brown 4’’ Baseboard and Brown Glue

N side of CLC 1st Floor

ND

5B S side of CLC 1st Floor 5C Center of CLC 1st Floor 5D S side of CLC 2nd Floor 5E W side of CLC 2nd Floor

HA6

6A

Bark Brown 8’’ Baseboard and Brown Glue

S side of CLC 1st Floor ND6B S side of CLC 1st Floor

6C S side of CLC 1st Floor

HA7

7A

Beige/White 12’’x12’’ Vinyl Floor Tile and Green Glue

N side of CLC 1st Floor ND7B N side of CLC 1st Floor

7C N side of CLC 1st Floor

HA8

8A

White with Brown Strips 12’’x12’’ Vinyl Floor Tile and

Black Mastic

N side of CLC 1st Floor

Black Mastic (3%

Chrysotile)

8B N Side of CLC 1st Floor

8C S side of CLC 1st Floor

8D E side of CLC 1st Floor 8E NW side of CLC 2nd Floor 8F S side of CLC 2nd Floor 8G E side of CLC 2nd Floor

February 16, 2023 | Terracon Report No. H8227090

Facilities | Environmental | Geotechnical | Materials 2

HA

Number

Sample Number

Material Description Material Location Lab Results

9A

9A

Perimeter Drywall and Joint Compound

W side of CLC 1st Floor

ND

9B N Side of CLC 1st Floor 9C S side of CLC 1st Floor 9D E side of CLC 1st Floor 9E NW side of CLC 2nd Floor 9F N side of CLC 2nd Floor 9G SE side of CLC 2nd Floor

HA10

10A

Interior Drywall and Joint Compound

W side of CLC 1st Floor

ND

10B Center of CLC 1st Floor 10C S side of CLC 1st Floor 10D S side of CLC 1st Floor 10E S side of CLC 2nd Floor 10F SW side of CLC 2nd Floor 10G Center of CLC 2nd Floor

HA11

11A

Light Brown/Brown Vinyl Floor Sheeting and Clear Glue

N side of CLC 1st Floor

ND

11B E side of CLC 1st Floor 11C S side of CLC 1st Floor 11D SW side of CLC 2nd Floor 11E N side of CLC 2nd Floor 11F E side of CLC 2nd Floor

HA12

12A

Dark Brown Vinyl Floor Sheeting and Grey Glue

S side of CLC 1st Floor ND12B S side of CLC 1st Floor

12C S side of CLC 1st Floor

HA13

13A

Dark Brown 17’’x17’’ Vinyl Floor Tile and Brown Glue

S side of CLC 1st Floor ND13B S side of CLC 1st Floor

13C S side of CLC 1st Floor

HA14

14A White with Large Brown Strips and 12’’x12’’ Vinyl Floor Tile and Yellow Glue

S side of CLC 1st Floor ND14B S side of CLC 1st Floor

14C S side of CLC 1st Floor

HA15

15A Off White 4’’x4’’ Ceramic Wall Tile, Grout, Thinset and Brown

Glue

N side of CLC 1st Floor

ND

15B Center of CLC 1st Floor 15C Center of CLC 1st Floor 15D S side of CLC 2nd Floor 15E N side of CLC 2nd Floor

HA16

16A Brown 1’’x1’’ Ceramic Floor

Tile, Grout, Thinset and Brown Glue

N side of CLC 1st Floor

ND

16B N side of CLC 1st Floor 16C S side of CLC 1st Floor 16D N side of CLC 2nd Floor 16E S side of CLC 2nd Floor

HA17

17A Off White with Brown Strips 12’’x12’’ Vinyl Floor Tile and

Yellow Glue

N side of CLC 1st Floor

ND

17B Center of CLC 1st Floor 17C S side of CLC 1st Floor 17D Center of CLC 2nd Floor 17E Center of CLC 2nd Floor

February 16, 2023 | Terracon Report No. H8227090

Facilities | Environmental | Geotechnical | Materials 3

HA

Number

Sample Number

Material Description Material Location Lab Results

HA18

18A White with Colors Dots

12’’x’12’’ Vinyl Floor Tile and Brown Glue

S side of CLC 1st Floor ND18B S Side of CLC 1st Floor

18C S side of CLC 1st Floor

HA19

19A White with Blue Strips 12’’x’12’’ Vinyl Floor Tile and Green Glue over White 12’’x12’’ Vinyl Floor

Tile and Brown Glue

S side of CLC 1st Floor

ND19B S Side of CLC 1st Floor

19C S Side of CLC 1st Floor

HA20

20A

White Mastic on HVAC Ducts

W Side of CLC 1st Floor

ND

20B S Side of CLC 1st Floor 20C E Side of CLC 1st Floor 20D W Side of CLC 2nd Floor 20E E Side of CLC 2nd Floor

HA21

21A

Grey Mastic on Metal HVAC Ducts

W Side of CLC 1st Floor

ND

21B N Side of CLC 1st Floor 21C S Side of CLC 1st Floor 21D Center of CLC 2nd Floor 21E N Side of CLC 2nd Floor

HA22

22A

Brown Sprayed on Wall Insulation

W Side of CLC 1st Floor

ND

22B NE Side of CLC 1st Floor 22C E Side of CLC 1st Floor 22D NW Side of CLC 2nd Floor 22E SE Side of CLC 2nd Floor

HA23

23A

White/Red Wallpaper and Clear Glue

SE Side of CLC 1st Floor ND23B N Side of CLC 1st Floor

23C W Side of CLC 1st Floor

HA24

24A Grey 5’’X5’’ Ceramic Floor

Tile, Grout, Thinset and Black Mastic

S Side of CLC 1st Floor Black Mastic (3%

Chrysotile) 24B S Side of CLC 1st Floor 24C S Side of CLC 1st Floor

HA25

25A

Brown Wallpaper and Clear Glue

NW Side of CLC 2nd Floor ND25B NE Side of CLC 2nd Floor

25C NE Side of CLC 2nd Floor

HA26

26A

Brown 4’’x4’’ Ceramic Wall Tile, Thinset and Brown Glue

NW Side of CLC 2nd Floor ND26B NW Side of CLC 2nd Floor

26C NW Side of CLC 2nd Floor

HA27

27A

Brown Gravel/Epoxy Flooring NW Side of CLC 2nd Floor

ND27B NW Side of CLC 2nd Floor 27C NW Side of CLC 2nd Floor

HA28

28A Off White with Brown Strips

12’’x12’’ Vinyl Floor Tile and Black Mastic

SW Side of CLC 2nd Floor Black Mastic (3%

Chrysotile) 28B Center of CLC 2nd Floor 28C SE Side of CLC 2nd Floor

HA29

29A Light Brown Wood Pattern

3’’x36’’ Vinyl Floor Tile and Brown Glue

S Side of CLC 2nd Floor ND29B S Side of CLC 2nd Floor

29C S Side of CLC 2nd Floor

Facilities | Environmental | Geotechnical | Materials

Appendix B

Asbestos Analytical Laboratory Data

Approved by:

Approved Signatory Tran Annie Nguyen

Report for:

Mr. Sergio Adasme Terracon - Fort Lauderdale, FL 5371 NW 33rd Ave.

Suite 201 Fort Lauderdale, FL 33309

Regarding:

Eurofins EPK Built Environment Testing, LLC Project: VA Hospital -CLC 1st and 2nd Floors; 120 NW 16th Street Miami FL

EML ID: 3154721

All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the samples as received and tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.

Eurofins EPK Built Environment Testing, LLC ("the Company"), a member of the Eurofins Built Environment Testing group of companies, shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.

Dates of Analysis:

Asbestos PLM: 02-07-2023

Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EM-AS-S-1267) NVLAP Lab Code 600274-0

EMLab ID: 3154721, Page 1 of 35Eurofins EPK Built Environment Testing, LLC

Eurofins EPK Built Environment Testing, LLC 5750 S. Semoran Blvd., Orlando, FL 32822

(866) 871-1984 www.eurofinsus.com/BuiltClient: Terracon - Fort Lauderdale, FL

C/O: Mr. Sergio Adasme Re: VA Hospital -CLC 1st and 2nd Floors; 120 NW 16th Street Miami FL

Date of Sampling: 02-02-2023 Date of Receipt: 02-03-2023 Date of Report: 02-07-2023

ASBESTOS PLM REPORT

Total Samples Submitted: 128 Total Samples Analyzed: 128

Total Samples with Layer Asbestos Content > 1%: 13

Location: 1A, White 2'x2' worm Ceiling Tile- 1st Floor Lab ID-Version‡: 15253845-1

Sample Layers Asbestos Content Gray Ceiling Tile ND

White Coating ND Composite Non-Asbestos Content: 40% Cellulose

20% Mineral Wool Sample Composite Homogeneity: Moderate

Location: 1B, White 2'x2' worm Ceiling Tile- 1st Floor Lab ID-Version‡: 15253846-1

Sample Layers Asbestos Content Gray Ceiling Tile ND

White Coating ND Composite Non-Asbestos Content: 40% Cellulose

20% Mineral Wool Sample Composite Homogeneity: Moderate

Location: 1C, White 2'x2' worm Ceiling Tile- 1st Floor Lab ID-Version‡: 15253847-1

Sample Layers Asbestos Content Gray Ceiling Tile ND

White Coating ND Composite Non-Asbestos Content: 40% Cellulose

20% Mineral Wool Sample Composite Homogeneity: Moderate

Location: 1D, White 2'x2' worm Ceiling Tile- 1st Floor Lab ID-Version‡: 15253848-1

Sample Layers Asbestos Content Gray Ceiling Tile ND

White Coating ND Composite Non-Asbestos Content: 40% Cellulose

20% Mineral Wool Sample Composite Homogeneity: Moderate

EMLab ID: 3154721, Page 2 of 35Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

(866) 871-1984 www.eurofinsus.com/BuiltClient: Terracon - Fort Lauderdale, FL

C/O: Mr. Sergio Adasme Re: VA Hospital -CLC 1st and 2nd Floors; 120 NW 16th Street Miami FL

Date of Sampling: 02-02-2023 Date of Receipt: 02-03-2023 Date of Report: 02-07-2023

ASBESTOS PLM REPORT

Location: 1E, White 2'x2' worm Ceiling Tile- 2nd Floor Lab ID-Version‡: 15253849-1

Sample Layers Asbestos Content Gray Ceiling Tile ND

White Coating ND Composite Non-Asbestos Content: 40% Cellulose

20% Mineral Wool Sample Composite Homogeneity: Moderate

Location: 1F, White 2'x2' worm Ceiling Tile- 2nd Floor Lab ID-Version‡: 15253850-1

Sample Layers Asbestos Content White Coating ND

Gray Ceiling Tile ND Composite Non-Asbestos Content: 40% Cellulose

20% Mineral Wool Sample Composite Homogeneity: Moderate

Location: 1G, White 2'x2' worm Ceiling Tile- 2nd Floor Lab ID-Version‡: 15253851-1

Sample Layers Asbestos Content White Coating ND

Gray Ceiling Tile ND Composite Non-Asbestos Content: 40% Cellulose

20% Mineral Wool Sample Composite Homogeneity: Moderate

Location: 2A, Drywall and Joint Compound Ceiling-1st Floor Lab ID-Version‡: 15253852-1

Sample Layers Asbestos Content White Joint Compound ND

Brown Paper ND Off-White Drywall ND

Composite Non-Asbestos Content: 10% Cellulose Sample Composite Homogeneity: Moderate

EMLab ID: 3154721, Page 3 of 35Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(866) 871-1984 www.eurofinsus.com/BuiltClient: Terracon - Fort Lauderdale, FL

C/O: Mr. Sergio Adasme Re: VA Hospital -CLC 1st and 2nd Floors; 120 NW 16th Street Miami FL

Date of Sampling: 02-02-2023 Date of Receipt: 02-03-2023 Date of Report: 02-07-2023

ASBESTOS PLM REPORT

Location: 2B, Drywall and Joint Compound Ceiling-1st Floor Lab ID-Version‡: 15253853-1

Sample Layers Asbestos Content White Joint Compound ND

Brown Paper ND Off-White Drywall ND

Composite Non-Asbestos Content: 10% Cellulose Sample Composite Homogeneity: Moderate

Location: 2C, Drywall and Joint Compound Ceiling-1st Floor Lab ID-Version‡: 15253854-1

Sample Layers Asbestos Content White Joint Compound ND

Brown Paper ND Off-White Drywall ND

Composite Non-Asbestos Content: 10% Cellulose Sample Composite Homogeneity: Moderate

Location: 2D, Drywall and Joint Compound Ceiling-1st Floor Lab ID-Version‡: 15253855-1

Sample Layers Asbestos Content White Joint Compound ND

Brown Paper ND Off-White Drywall ND

Composite Non-Asbestos Content: 10% Cellulose Sample Composite Homogeneity: Moderate

Location: 2E, Drywall and Joint Compound Ceiling-2nd Floor Lab ID-Version‡: 15253856-1

Sample Layers Asbestos Content White Joint Compound ND

Brown Paper ND Off-White Drywall ND

Composite Non-Asbestos Content: 10% Cellulose Sample Composite Homogeneity: Moderate

EMLab ID: 3154721, Page 4 of 35Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(866) 871-1984 www.eurofinsus.com/BuiltClient: Terracon - Fort Lauderdale, FL

C/O: Mr. Sergio Adasme Re: VA Hospital -CLC 1st and 2nd Floors; 120 NW 16th Street Miami FL

Date of Sampling: 02-02-2023 Date of Receipt: 02-03-2023 Date of Report: 02-07-2023

ASBESTOS PLM REPORT

Location: 2F, Drywall and Joint Compound Ceiling-2nd Floor Lab ID-Version‡: 15253857-1

Sample Layers Asbestos Content White Joint Compound ND

Brown Paper ND Off-White Drywall ND

Composite Non-Asbestos Content: 10% Cellulose Sample Composite Homogeneity: Moderate

Location: 2G, Drywall and Joint Compound Ceiling-2nd Floor Lab ID-Version‡: 15253858-1

Sample Layers Asbestos Content White Joint Compound ND

Brown Paper ND Off-White Drywall ND

Composite Non-Asbestos Content: 10% Cellulose Sample Composite Homogeneity: Moderate

Location: 3A, Pink Fiber Glass Reinforced Panel and Brown Glue- 1st Floor Lab ID-Version‡: 15253859-1

Sample Layers Asbestos Content Brown Glue ND

Pink Fiberglass Reinforced Plastic ND Sample Composite Homogeneity: Moderate

Location: 3B, Pink Fiber Glass Reinforced Panel and Brown Glue- 1st Floor Lab ID-Version‡: 15253860-1

Sample Layers Asbestos Content White Texture ND Brown Glue ND

Pink Fiberglass Reinforced Plastic ND Sample Composite Homogeneity: Moderate

EMLab ID: 3154721, Page 5 of 35Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(866) 871-1984 www.eurofinsus.com/BuiltClient: Terracon - Fort Lauderdale, FL

C/O: Mr. Sergio Adasme Re: VA Hospital -CLC 1st and 2nd Floors; 120 NW 16th Street Miami FL

Date of Sampling: 02-02-2023 Date of Receipt: 02-03-2023 Date of Report: 02-07-2023

ASBESTOS PLM REPORT

Location: 3C, Pink Fiber Glass Reinforced Panel and Brown Glue- 1st Floor Lab ID-Version‡: 15253861-1

Sample Layers Asbestos Content Brown Glue ND

Pink Fiberglass Reinforced Plastic ND Sample Composite Homogeneity: Moderate

Location: 3D, Pink Fiber Glass Reinforced Panel and Brown Glue- 2nd Floor Lab ID-Version‡: 15253862-1

Sample Layers Asbestos Content Brown Glue ND

Pink Fiberglass Reinforced Plastic ND Sample Composite Homogeneity: Moderate

Location: 3E, Pink Fiber Glass Reinforced Panel and Brown Glue- 2nd Floor Lab ID-Version‡: 15253863-1

Sample Layers Asbestos Content Brown Glue ND

Pink Fiberglass Reinforced Plastic ND Sample Composite Homogeneity: Moderate

Location: 4A, Brown Wall Panel Brown Glue -1st Floor Lab ID-Version‡: 15253864-1

Sample Layers Asbestos Content Brown Glue ND

Brown Non-Fibrous Material ND Sample Composite Homogeneity: Moderate

EMLab ID: 3154721, Page 6 of 35Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(866) 871-1984 www.eurofinsus.com/BuiltClient: Terracon - Fort Lauderdale, FL

C/O: Mr. Sergio Adasme Re: VA Hospital -CLC 1st and 2nd Floors; 120 NW 16th Street Miami FL

Date of Sampling: 02-02-2023 Date of Receipt: 02-03-2023 Date of Report: 02-07-2023

ASBESTOS PLM REPORT

Location: 4B, Brown Wall Panel Brown Glue -1st Floor Lab ID-Version‡: 15253865-1

Sample Layers Asbestos Content Brown Glue ND

Brown Non-Fibrous Material ND Sample Composite Homogeneity: Moderate

Location: 4C, Brown Wall Panel Brown Glue -1st Floor Lab ID-Version‡: 15253866-1

Sample Layers Asbestos Content Brown Glue ND

Brown Non-Fibrous Material ND Sample Composite Homogeneity: Moderate

Location: 4D, Brown Wall Panel Brown Glue -2nd Floor Lab ID-Version‡: 15253867-1

Sample Layers Asbestos Content Brown Glue ND

Brown Non-Fibrous Material ND Sample Composite Homogeneity: Moderate

Location: 4E, Brown Wall Panel Brown Glue -2nd Floor Lab ID-Version‡: 15253868-1

Sample Layers Asbestos Content Brown Glue ND

Brown Non-Fibrous Material ND Sample Composite Homogeneity: Moderate

EMLab ID: 3154721, Page 7 of 35Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(866) 871-1984 www.eurofinsus.com/BuiltClient: Terracon - Fort Lauderdale, FL

C/O: Mr. Sergio Adasme Re: VA Hospital -CLC 1st and 2nd Floors; 120 NW 16th Street Miami FL

Date of Sampling: 02-02-2023 Date of Receipt: 02-03-2023 Date of Report: 02-07-2023

ASBESTOS PLM REPORT

Location: 5A, Brown 4" Baseboard and Brown Glue- 1st Floor Lab ID-Version‡: 15253869-1

Sample Layers Asbestos Content Brown Glue ND

Brown Baseboard ND Sample Composite Homogeneity: Moderate

Location: 5B, Brown 4" Baseboard and Brown Glue- 1st Floor Lab ID-Version‡: 15253870-1

Sample Layers Asbestos Content Brown Glue ND

Brown Baseboard ND Sample Composite Homogeneity: Moderate

Location: 5C, Brown 4" Baseboard and Brown Glue- 1st Floor Lab ID-Version‡: 15253871-1

Sample Layers Asbestos Content Brown Glue ND

Brown Baseboard ND Sample Composite Homogeneity: Moderate

Location: 5D, Brown 4" Baseboard and Brown Glue- 2nd Floor Lab ID-Version‡: 15253872-1

Sample Layers Asbestos Content Brown Glue ND

Brown Baseboard ND Sample Composite Homogeneity: Moderate

EMLab ID: 3154721, Page 8 of 35Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(866) 871-1984 www.eurofinsus.com/BuiltClient: Terracon - Fort Lauderdale, FL

C/O: Mr. Sergio Adasme Re: VA Hospital -CLC 1st and 2nd Floors; 120 NW 16th Street Miami FL

Date of Sampling: 02-02-2023 Date of Receipt: 02-03-2023 Date of Report: 02-07-2023

ASBESTOS PLM REPORT

Location: 5E, Brown 4" Baseboard and Brown Glue- 2nd Floor Lab ID-Version‡: 15253873-1

Sample Layers Asbestos Content Brown Glue ND

Brown Baseboard ND Sample Composite Homogeneity: Moderate

Location: 6A, Dark Brown 8" Baseboard and Brown Glue- 1st Floor Lab ID-Version‡: 15253874-1

Sample Layers Asbestos Content White Texture ND Brown Glue ND

Dark Brown Baseboard ND Sample Composite Homogeneity: Moderate

Location: 6B, Dark Brown 8" Baseboard and Brown Glue- 1st Floor Lab ID-Version‡: 15253875-1

Sample Layers Asbestos Content Brown Glue ND

Dark Brown Baseboard ND Sample Composite Homogeneity: Moderate

Location: 6C, Dark Brown 8" Baseboard and Brown Glue- 1st Floor Lab ID-Version‡: 15253876-1

Sample Layers Asbestos Content White Texture ND Brown Glue ND

Dark Brown Baseboard ND Sample Composite Homogeneity: Moderate

EMLab ID: 3154721, Page 9 of 35Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(866) 871-1984 www.eurofinsus.com/BuiltClient: Terracon - Fort Lauderdale, FL

C/O: Mr. Sergio Adasme Re: VA Hospital -CLC 1st and 2nd Floors; 120 NW 16th Street Miami FL

Date of Sampling: 02-02-2023 Date of Receipt: 02-03-2023 Date of Report: 02-07-2023

ASBESTOS PLM REPORT

Location: 7A, Beige/ White 12x12 Vinyl Floor Tile and Green Glue- 1st Floor Lab ID-Version‡: 15253877-1

Sample Layers Asbestos Content Green Glue ND

Beige Floor Tile ND Sample Composite Homogeneity: Moderate

Location: 7B, Beige/ White 12x12 Vinyl Floor Tile and Green Glue- 1st Floor Lab ID-Version‡: 15253878-1

Sample Layers Asbestos Content Green Glue ND

Beige Floor Tile ND Sample Composite Homogeneity: Moderate

Location: 7C, Beige/ White 12x12 Vinyl Floor Tile and Green Glue- 1st Floor Lab ID-Version‡: 15253879-1

Sample Layers Asbestos Content Green Glue ND

Beige Floor Tile ND Sample Composite Homogeneity: Moderate

Location: 8A, White with Brown strips 12'x12" Vinyl Floor Tile and Black Mastic-1st Floor Lab ID-Version‡: 15253880-1

Sample Layers Asbestos Content Black Mastic 3% Chrysotile

White Floor Tile ND Sample Composite Homogeneity: Moderate

EMLab ID: 3154721, Page 10 of 35Eurofins EPK Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(866) 871-1984 www.eurofinsus.com/BuiltClient: Terracon - Fort Lauderdale, FL

C/O: Mr. Sergio Adasme Re: VA Hospital -CLC 1st and 2nd Floors; 120 NW 16th Street Miami FL

Date of Sampling: 02-02-2023 Date of Receipt: 02-03-2023 Date of Report: 02-07-2023

ASBESTOS PLM REPORT

Location: 8B, White with Brown strips 12'x12" Vinyl Floor Tile and Black Mastic-1st Floor Lab ID-Version‡: 15253881-1

Sample Layers Asbestos Content Black Mastic 3% Chrysotile

White Floor Tile ND Sample Composite Homogeneity: Moderate

Location: 8C, White with Brown strips 12'x12" Vinyl Floor Tile and Black Mastic-1st Floor Lab ID-Version‡: 15253882-1

Sample Layers Asbestos Content Black Mastic 3% Chrysotile

White Floor Tile ND Sample Composite Homogeneity: Moderate

Location: 8D, White with Brown strips 12'x12" Vinyl Floor Tile and Black Mastic-1st Floo Lab ID-Version‡: 15253883-1

Sample Layers Asbestos Content Black Mastic 3% Chrysotile

White Floor Tile ND Sample Composite Homogeneity:…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .