This document includes design drawings and specifications for a federal construction project along with details of the related solicitation opportunity. The project involves renovating restrooms at the C.W. Bill Young Medical Center campus of the Bay Pines VA located in Bay Pines, Florida. The estimated value of the project is between $5-10 million. The solicitation was issued on September 13, 2021 using a trade-off source selection process to provide best value to the government. Responses were due at the time of proposal submission, contractors must have been registered in SAM. The work is to be completed within 210 calendar days of NTP. The NAICS code is 236220 and the opportunity is 100% set aside for Service-Disabled Veteran-Owned Small Businesses. The Department of Veterans Affairs Veterans Health Administration VISN 8 is the contracting agency.

View the file

Other files

File Type Posted
P09_Final Con SOW 516-19-104 revised bldg. 24.docx DOCX document
36C24821R0199 0007.docx DOCX document
P09_24HA100 Drawing.pdf PDF
36C24821R0199 0006.docx DOCX document
DRW_24.PD101.pdf PDF
DRW_100.PD101.pdf PDF
36C24821R0199 0005.docx DOCX document
Drawing_24.PD101.pdf PDF
36C24821R0199 0004.docx DOCX document
S05_Answers_Request for Information 36C24821R0199_Round 2.docx DOCX document
36C24821R0199 0003.docx DOCX document
36C24821R0199 0002.docx DOCX document
S05_Answers_Request for Information 36C24821R0199_Round 1.docx DOCX document
S04_Pre-bid walk thru 10-14-21 sign-in sheets.pdf PDF
36C24821R0199 0001.docx DOCX document
Q_A Template.xlsx XLSX spreadsheet
36C24821R0199.docx DOCX document
P07_Wage determination.pdf PDF
Limitations on Subcontracting Certification Renovate Station Restrooms.pdf PDF
Price Matrix.xlsx XLSX spreadsheet
516-19-104 Specifications.pdf PDF
Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Architecture Engineering Design-Build paradigm

J:\

BA

P1

1 - B ay P ine s R en ov ate S tat ion

R es tro om s\P ro jec t\A cti ve

C

AD

\M

PF

P\

0.P D1

.dw g, 6/2

/20

:08

:30 A

M

AutoCAD SHX Text

EWC

AutoCAD SHX Text

EWC

AutoCAD SHX Text 22.6

AutoCAD SHX Text 22.1

AutoCAD SHX Text 21.2

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text L

AutoCAD SHX Text M

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

100.PD100

AutoCAD SHX Text 9 Oak Drive, Ocala, FL 34472 - www.paradigmusa.com

AutoCAD SHX Text

BID DOCUMENTS FOR CONSTRUCTION

AutoCAD SHX Text

FULLY SPRINKLERED

AutoCAD SHX Text

RENOVATE STATION RESTROOMS

AutoCAD SHX Text 516-19-104

AutoCAD SHX Text 06-04-2021

AutoCAD SHX Text

10000 BAY PINES BLVD., BAY PINES, FL 33744

AutoCAD SHX Text

C.W. BILL YOUNG VAMCBILL YOUNG VAMC

AutoCAD SHX Text

OVERALL PLUMBING PLAN BUILDING 100

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

KEY PLAN - BUILDING 100

AutoCAD SHX Text N

AutoCAD SHX Text

AutoCAD SHX Text GENERAL NOTES A. REFER TO G.P-001 FOR PLUMBING ABBREVIATIONS, SYMBOLS, AND REFER TO G.P-001 FOR PLUMBING ABBREVIATIONS, SYMBOLS, AND GENERAL NOTES RELATED TO THIS SHEET. B. ALL EXISTING PIPING, DUCTWORK, SPRINKLERS, CONDUIT, LIGHTING ALL EXISTING PIPING, DUCTWORK, SPRINKLERS, CONDUIT, LIGHTING OR OTHER CONSTRUCTION SHALL BE RELOCATED AS REQUIRED FOR ALL DEMOLITION AND INSTALLATION WORK. C. COMPLETE LAYOUT DRAWINGS SHALL BE REQUIRED BY PARAGRAPH COMPLETE LAYOUT DRAWINGS SHALL BE REQUIRED BY PARAGRAPH 1.4 SUBMITTALS OF ALL SPECIFICATION SECTIONS. CONSTRUCTION WORK SHALL NOT START ON ANY SYSTEM UNTIL THE LAYOUT DRAWINGS HAVE BEEN APPROVED.

AutoCAD SHX Text EXISTING AS-BUILT NOTES A. ALL INFORMATION DEPICTED IN THIS DRAWING HAS BEEN ACQUIRED ALL INFORMATION DEPICTED IN THIS DRAWING HAS BEEN ACQUIRED BY AND LIMITED TO THE AS-BUILT DRAWING "100-P24", GENERATED BY "SHS ASSOCIATES INC.", ON DATE JULY 2, 1979 (AS-BUILT DATE MARCH 4, 1983), PROVIDED BY THE BAY PINES VAMC AND EXTENSIVE ON-SITE NON-DESTRUCTIVE REVIEW.

AutoCAD SHX Text F3

AutoCAD SHX Text

SCALE 1/32'' = 1'-0''

AutoCAD SHX Text

OVERALL PLUMBING PLAN BUILDING 100

AutoCAD SHX Text

100.PD101

AutoCAD SHX Text F2

AutoCAD SHX Text

100.PD102

AutoCAD SHX Text F1

AutoCAD SHX Text

REFER TO EXISTING AS-BUILT NOTE "A"

AutoCAD SHX Text F2

AutoCAD SHX Text F1

AutoCAD SHX Text

100.PP101

AutoCAD SHX Text F2

AutoCAD SHX Text

100.PP102

AutoCAD SHX Text F1

AutoCAD SHX Text

JLD

AutoCAD SHX Text

RWI

AutoCAD SHX Text

RWI

Sheets and Views
516-19-104_100.PD101