This document describes a federal contract opportunity for site preparation and installation of a temporary modular kitchen at the C.W. Bill Young Medical Center in Bay Pines, Florida. The solicitation number is 36C24821R0051 and seeks a contractor to design, fabricate, deliver, prepare the site and install the temporary kitchen unit. The estimated target completion period is 365 calendar days after notice to proceed. The magnitude of the project is between $1,000,000 and $2,000,000. The solicitation will use a trade-off source selection process and be issued on or around February 3, 2021. Interested contractors must be registered in the System for Award Management. The contracting officer point of contact is Ashley Commiso. This procurement is set aside for service-disabled veteran-owned small businesses and veteran-owned small businesses, with tiered evaluations in that order of priority.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| MK - 1 MODULAR KITCHEN ATTACHMENT D Model (1).pdf | ||
| 36C24821R0051 0002.docx | DOCX document | |
| 516-15-105 TEMP KITCHEN STREET SITE PICS- ATTACHMENT B.docx | DOCX document | |
| 516-15-105 TEMP KITCHEN-OVER LAY-ATTACHMENT A.docx | DOCX document | |
| Government Responses.pdf | ||
| VA SUPPLIED EQUIP-TEMP KITCHEN-ATTACHMENT C.docx | DOCX document | |
| 36C24821R0051 0001_1.docx | DOCX document | |
| 95 pct Combined Drawings_Temp Kitchen extract.pdf | ||
| 36C24821R0051.docx | DOCX document | |
| Spec 00 11 21 SITE PREP-PROJECT 516-15-105 INSTALL TEMP KITCHEN .pdf | ||
| Spec 13 34 19 -PROJECT 516-15-105 INSTALL TEMP KITCHEN.pdf | ||
| FL20210222 22Jan2021.pdf | ||
| Limitations on Subcontracting Certification Temp Kitchen.pdf | ||
| Q_A Template.xlsx | XLSX spreadsheet |
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAWING TITLE
DWG
NO.
INDEX OF DRAWINGS
DRAWING TITLE
DWG
NO.
PROJECT LOCATION
A/E RENOVATE KITCHEN
BUILDING 100
95% SUBMITTAL
BAY PINES, FL
PROJECT No 516-15-105
BAY PINES VAMC,
FLORIDA
SPORTS
COURT
GERIATRIC COURTYARD
DINING COURTYARD
KIDS PLAY AREA.
WATER FEATURE WATER FEATURE
PLAZA
P
E
D
W
A
Y
DRAWING TITLE
DWG
NO.
COVER SHEET
G001
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
95% SUBMITTAL
FULLY SPRINKLERED
Phase
A/E RENOVATE KITCHEN
BUILDING 100
BAY PINES VAHCS, FLORIDA
516-15-105
12/18/2020 AT CC/SJ
AutoCAD SHX Text
AutoCAD SHX Text
AREA MAP
AutoCAD SHX Text
AutoCAD SHX Text
LOCATION MAP
AutoCAD SHX Text
GENERAL
AutoCAD SHX Text
FIRE PROTECTION
AutoCAD SHX Text
PLUMBING
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
ARCHITECTURAL
AutoCAD SHX Text
ABATEMENT
AutoCAD SHX Text
AD100
AutoCAD SHX Text
PARTIAL FIRST FLOOR DEMO PLAN
AutoCAD SHX Text G001
AutoCAD SHX Text
COVER SHEET
AutoCAD SHX Text G002
AutoCAD SHX Text
LEGENDS, ABBREVIATIONS, AND NOTES
AutoCAD SHX Text
QF100
AutoCAD SHX Text
FOODSERVICE EQUIPMENT OVERALL PLAN
AutoCAD SHX Text
FOODSERVICE FLOOR PLAN - NORTH
AutoCAD SHX Text
FOODSERVICE FLOOR PLAN - SOUTH
AutoCAD SHX Text
AD101
AutoCAD SHX Text
PARTIAL FIRST FLOOR DEMO RCP
AutoCAD SHX Text A100
AutoCAD SHX Text
PARTIAL FIRST FLOOR PLAN
AutoCAD SHX Text A101
AutoCAD SHX Text
PARTIAL FIRST FLOOR RCP
AutoCAD SHX Text A500
AutoCAD SHX Text
PARTITION TYPES AND DETAILS
AutoCAD SHX Text A601
AutoCAD SHX Text
ROOM FINISH SCHEDULE AND LEGEND
AutoCAD SHX Text A602
AutoCAD SHX Text
DOOR AND FRAME TYPES, SCHEDULE AND DETAILS
AutoCAD SHX Text M001
AutoCAD SHX Text
MD103
AutoCAD SHX Text
1ST FLOOR INTERSTITIAL, PART B SUPPLY DUCTWORK DEMOLITION PLAN - MECHANICAL
AutoCAD SHX Text
LEGENDS AND GENERAL NOTES - MECHANICAL
AutoCAD SHX Text
MD104
AutoCAD SHX Text
1ST FLOOR INTERSTITIAL, PART B PIPING DEMOLITION PLAN - MECHANICAL
AutoCAD SHX Text
MD105
AutoCAD SHX Text
1ST FLOOR INTERSTITIAL, PART B RETURN DUCTWORK DEMOLITION PLAN - MECHANICAL
AutoCAD SHX Text M101
AutoCAD SHX Text
PARTIAL KITCHEN NEW WORK PLAN - MECHANICAL
AutoCAD SHX Text M103
AutoCAD SHX Text M501
AutoCAD SHX Text
DETAILS - MECHANICAL
AutoCAD SHX Text M502
AutoCAD SHX Text
DETAILS - MECHANICAL
AutoCAD SHX Text M601
AutoCAD SHX Text
SCHEDULES - MECHANICAL
AutoCAD SHX Text
AS100
AutoCAD SHX Text
TEMPORARY KITCHEN COMPLEX SITE LAYOUT PLAN
AutoCAD SHX Text P001
AutoCAD SHX Text
LEGENDS, ABBREVIATIONS, GENERAL NOTES, AND DETAILS
AutoCAD SHX Text
PD101
AutoCAD SHX Text
DEMOLITION FOUNDATION PIPING PLAN - MAIN KITCHEN
AutoCAD SHX Text
PL101
AutoCAD SHX Text
FOUNDATION PIPING PLAN - MAIN KITCHEN
AutoCAD SHX Text
FD101
AutoCAD SHX Text
FIRE PROTECTION DEMOLITION PLAN
AutoCAD SHX Text
FP101
AutoCAD SHX Text
FIRE PROTECTION NEW WORK PLAN
AutoCAD SHX Text E001
AutoCAD SHX Text
LEGENDS AND SCHEDULES
AutoCAD SHX Text
ED101
AutoCAD SHX Text
DEMOLITION LIGHTING PLAN - ELECTRICAL
AutoCAD SHX Text E501
AutoCAD SHX Text
DETAILS
AutoCAD SHX Text E601
AutoCAD SHX Text
PANELBOARD SCHEDULES
AutoCAD SHX Text
QF101
AutoCAD SHX Text
QF102
AutoCAD SHX Text
BUILDING
AutoCAD SHX Text A400
AutoCAD SHX Text
ENLARGED MAIN KITCHEN FLOOR PLAN
AutoCAD SHX Text A401
AutoCAD SHX Text
INTERIOR ELEVATIONS AND DETAILS
AutoCAD SHX Text
AB100
AutoCAD SHX Text
ABATEMENT PLANS
AutoCAD SHX Text
MD101
AutoCAD SHX Text
PARTIAL KITCHEN DEMOLITION PLAN - MECHANICAL
AutoCAD SHX Text
MD102
AutoCAD SHX Text
PARTIAL KITCHEN DEMOLITION PLAN - MECHANICAL
AutoCAD SHX Text
MD107
AutoCAD SHX Text
1ST FLOOR INTERSTITIAL, PART C SUPPLY DUCTWORK DEMOLITION PLAN - MECHANICAL
AutoCAD SHX Text
MD111
AutoCAD SHX Text 5TH FLOOR INTERSTITIAL MECHANICAL ROOM AND ROOF EXHAUST DUCTWORK DEMOLITION PLAN - MECHANICAL
AutoCAD SHX Text M102
AutoCAD SHX Text
PARTIAL KITCHEN NEW WORK PLAN - MECHANICAL
AutoCAD SHX Text M104
AutoCAD SHX Text M105
AutoCAD SHX Text M106
AutoCAD SHX Text M111
AutoCAD SHX Text
1ST FLOOR INTERSTITIAL, PART B SUPPLY DUCTWORK NEW WORK PLAN - MECHANICAL
AutoCAD SHX Text
1ST FLOOR INTERSTITIAL, PART B PIPING NEW WORK PLAN - MECHANICAL
AutoCAD SHX Text
1ST FLOOR INTERSTITIAL, PART B RETURN DUCTWORK NEW WORK PLAN - MECHANICAL
AutoCAD SHX Text
1ST FLOOR INTERSTITIAL, PART B EXHAUST DUCTWORK NEW WORK PLAN - MECHANICAL
AutoCAD SHX Text 5TH FLOOR INTERSTITIAL MECHANICAL ROOM AND ROOF EXHAUST DUCTWORK NEW WORK PLAN - MECHANICAL
AutoCAD SHX Text M801
AutoCAD SHX Text
CONTROL SCHEMATIC, CONTROL SCHEDULES AND LEGEND - MECHANICAL
AutoCAD SHX Text M802
AutoCAD SHX Text
SEQUENCE OF CONTROLS - MECHANICAL
AutoCAD SHX Text Q101
AutoCAD SHX Text
ENLARGED TEMPORARY KITCHEN SITE LAYOUT PLAN AND DETAILS
AutoCAD SHX Text Q102
AutoCAD SHX Text
INTERIM KITCHEN COMPLEX PLAN
AutoCAD SHX Text Q103A
AutoCAD SHX Text
INTERIM KITCHEN COMPLEX UTILITIES PLAN - AREA A
AutoCAD SHX Text Q103B
AutoCAD SHX Text
INTERIM KITCHEN COMPLEX UTILITIES PLAN - AREA B
AutoCAD SHX Text Q104A
AutoCAD SHX Text
INTERIM KITCHEN COMPLEX ROOF UTILITIES PLAN - AREA A
AutoCAD SHX Text Q104B
AutoCAD SHX Text Q105
AutoCAD SHX Text
INTERIM KITCHEN COMPLEX UTILITIES SCHEDULE
AutoCAD SHX Text
QF103
AutoCAD SHX Text
FOODSERVICE 3D VIEWS
AutoCAD SHX Text
QF104
AutoCAD SHX Text
QF105
AutoCAD SHX Text
QF200
AutoCAD SHX Text
FOODSERVICE EQUIPMENT SCHEDULE
AutoCAD SHX Text
QF201
AutoCAD SHX Text
QF202
AutoCAD SHX Text
QF300
AutoCAD SHX Text
FOODSERVICE PLUMBING PLAN - SOUTH
AutoCAD SHX Text
FOODSERVICE PLUMBING SCHEDULE
AutoCAD SHX Text
QF301
AutoCAD SHX Text
QF302
AutoCAD SHX Text
FOODSERVICE ELECTRICAL PLAN - NORTH
AutoCAD SHX Text
FOODSERVICE ELECTRICAL PLAN - SOUTH
AutoCAD SHX Text
QF400
AutoCAD SHX Text
QF401
AutoCAD SHX Text
FOODSERVICE 3D VIEWS
AutoCAD SHX Text
FOODSERVICE 3D VIEWS
AutoCAD SHX Text
FOODSERVICE EQUIPMENT SCHEDULE
AutoCAD SHX Text
FOODSERVICE EQUIPMENT SCHEDULE
AutoCAD SHX Text
FOODSERVICE PLUMBING PLAN - NORTH
AutoCAD SHX Text
FOODSERVICE ELECTRICAL SCHEDULE
AutoCAD SHX Text
QF402
AutoCAD SHX Text
QF500
AutoCAD SHX Text
FOODSERVICE MECHANICAL PLAN - NORTH
AutoCAD SHX Text
FOODSERVICE MECHANICAL PLAN - SOUTH
AutoCAD SHX Text
FOODSERVICE EXHAUST HOOD DETAILS
AutoCAD SHX Text
QF501
AutoCAD SHX Text
QF502
AutoCAD SHX Text
FOODSERVICE EXHAUST HOOD DETAILS
AutoCAD SHX Text
QF503
AutoCAD SHX Text
FOODSERVICE EXHAUST HOOD DETAILS
AutoCAD SHX Text
QF504
AutoCAD SHX Text
FOODSERVICE EXHAUST HOOD DETAILS
AutoCAD SHX Text
QF505
AutoCAD SHX Text
FOODSERVICE UDS DETAILS
AutoCAD SHX Text
QF506
AutoCAD SHX Text
FOODSERVICE EXHAUST HOOD DETAILS
AutoCAD SHX Text
QF507
AutoCAD SHX Text
FOODSERVICE EXHAUST HOOD DETAILS
AutoCAD SHX Text
QF508
AutoCAD SHX Text
FOODSERVICE EXHAUST HOOD DETAILS
AutoCAD SHX Text
QF509
AutoCAD SHX Text
FOODSERVICE UDS DETAILS
AutoCAD SHX Text
QF510
AutoCAD SHX Text
FOODSERVICE DEMAND CONTROL VENTILATION DETAILS
AutoCAD SHX Text
QF511
AutoCAD SHX Text
FOODSERVICE SPECIAL CONDITIONS PLAN - NORTH
AutoCAD SHX Text
QF600
AutoCAD SHX Text
FOODSERVICE SPECIAL CONDITIONS PLAN - SOUTH
AutoCAD SHX Text
QF601
AutoCAD SHX Text
FOODSERVICE ENLARGED WALK-IN PLAN
AutoCAD SHX Text
QF602
AutoCAD SHX Text
FOODSERVICE WALK-IN DETAILS
AutoCAD SHX Text
QF603
AutoCAD SHX Text
FOODSERVICE REFRIGERATION RACK DETAILS
AutoCAD SHX Text
QF604
AutoCAD SHX Text
FOODSERVICE REFRIGERATION RACK DETAILS
AutoCAD SHX Text
QF605
AutoCAD SHX Text
FOODSERVICE REFRIGERATION RACK DETAILS
AutoCAD SHX Text
QF606
AutoCAD SHX Text
FOODSERVICE CUSTOM FABRICATION PLAN
AutoCAD SHX Text
QF700
AutoCAD SHX Text
FOODSERVICE ELEVATIONS
AutoCAD SHX Text
QF701
AutoCAD SHX Text
FOODSERVICE ELEVATIONS
AutoCAD SHX Text
QF702
AutoCAD SHX Text
FOODSERVICE ELEVATIONS
AutoCAD SHX Text
QF703
AutoCAD SHX Text
FOODSERVICE ELEVATIONS
AutoCAD SHX Text
QF704
AutoCAD SHX Text
FOODSERVICE CHEF COUNTER DETAILS
AutoCAD SHX Text
QF705
AutoCAD SHX Text
FOODSERVICE DETAILS
AutoCAD SHX Text
QF800
AutoCAD SHX Text
FOODSERVICE DETAILS
AutoCAD SHX Text
QF801
AutoCAD SHX Text
FOODSERVICE DETAILS
AutoCAD SHX Text
QF802
AutoCAD SHX Text
PD102
AutoCAD SHX Text
DEMOLITION PIPING FLOOR PLAN - MAIN KITCHEN
AutoCAD SHX Text
PD103
AutoCAD SHX Text
PD201
AutoCAD SHX Text
ENLARGED FOUNDATION PIPING PLAN - MAIN KITCHEN
AutoCAD SHX Text
DEMOLITION INTERSTITIAL PIPING PLAN - MAIN KITCHEN
AutoCAD SHX Text
PD202
AutoCAD SHX Text
ENLARGED FIRST FLOOR PIPING PLAN - MAIN KITCHEN
AutoCAD SHX Text
PD203
AutoCAD SHX Text
ENLARGED INTERSTITIAL PIPING PLAN - MAIN KITCHEN
AutoCAD SHX Text
PL102
AutoCAD SHX Text
FIRST FLOOR PIPING PLAN - MAIN KITCHEN
AutoCAD SHX Text
PL103
AutoCAD SHX Text
INTERSTITIAL PIPING PLAN - MAIN KITCHEN
AutoCAD SHX Text
PL202
AutoCAD SHX Text
ENLARGED FIRST FLOOR PIPING PLAN - MAIN KITCHEN
AutoCAD SHX Text
PL203
AutoCAD SHX Text
ENLARGED FINTERSTITIAL PIPING PLAN - MAIN KITCHEN
AutoCAD SHX Text
PL201
AutoCAD SHX Text
ENLARGED FOUNDATION PIPING PLAN - MAIN KITCHEN
AutoCAD SHX Text F001
AutoCAD SHX Text
LEGENDS, GENERAL NOTES, AND DETAILS
AutoCAD SHX Text
ED102
AutoCAD SHX Text
DEMOLITION POWER PLAN - ELECTRICAL
AutoCAD SHX Text
EL101
AutoCAD SHX Text
LIGHTING FLOOR PLAN
AutoCAD SHX Text
EP101
AutoCAD SHX Text
POWER FLOOR PLAN
AutoCAD SHX Text
EP401
AutoCAD SHX Text
KITCHEN LARGE SCALE POWER PLAN - NORTH
AutoCAD SHX Text
EP402
AutoCAD SHX Text
KITCHEN LARGE SCALE POWER PLAN - SOUTH
AutoCAD SHX Text E602
AutoCAD SHX Text
PANELBOARD SCHEDULES
AutoCAD SHX Text E603
AutoCAD SHX Text
PANELBOARD SCHEDULES
AutoCAD SHX Text E950
AutoCAD SHX Text
POWER RISER DIAGRAMS-SERVICE BAYS 2 & 3
AutoCAD SHX Text
EY101
AutoCAD SHX Text
SPECIAL SYSTEMS FLOOR PLAN
AutoCAD SHX Text
EY501
AutoCAD SHX Text
SPECIAL SYSTEMS DETAILS
AutoCAD SHX Text
EY502
AutoCAD SHX Text
SPECIAL SYSTEMS DETAILS
AutoCAD SHX Text
ARCHITECTURAL (CONTINUED)
AutoCAD SHX Text
MD106
AutoCAD SHX Text
1ST FLOOR INTERSTITIAL, PART B EXHAUST DUCTWORK DEMOLITION PLAN - MECHANICAL
AutoCAD SHX Text
MD108
AutoCAD SHX Text
1ST FLOOR INTERSTITIAL, PART C PIPING DEMOLITION PLAN - MECHANICAL
AutoCAD SHX Text
MD109
AutoCAD SHX Text
1ST FLOOR INTERSTITIAL, PART C RETURN DUCTWORK DEMOLITION PLAN - MECHANICAL
AutoCAD SHX Text
MD110
AutoCAD SHX Text
1ST FLOOR INTERSTITIAL, PART C EXHAUST DUCTWORK DEMOLITION PLAN - MECHANICAL
AutoCAD SHX Text M107
AutoCAD SHX Text M108
AutoCAD SHX Text M109
AutoCAD SHX Text M110
AutoCAD SHX Text
1ST FLOOR INTERSTITIAL, PART C SUPPLY DUCTWORK NEW WORK PLAN - MECHANICAL
AutoCAD SHX Text
1ST FLOOR INTERSTITIAL, PART C PIPING NEW WORK PLAN - MECHANICAL
AutoCAD SHX Text
1ST FLOOR INTERSTITIAL, PART C RETURN DUCTWORK NEW WORK PLAN - MECHANICAL
AutoCAD SHX Text
1ST FLOOR INTERSTITIAL, PART C EXHAUST DUCTWORK NEW WORK PLAN - MECHANICAL
AutoCAD SHX Text G003
AutoCAD SHX Text
PHASING PLANS AND NOTES
AutoCAD SHX Text
INTERIM KITCHEN COMPLEX ROOF UTILITIES PLAN - AREA B
AutoCAD SHX Text Q106A
AutoCAD SHX Text
INTERIM KITCHEN EQUIPMENT PLAN AND SCHEDULE - AREA A
AutoCAD SHX Text Q106B
AutoCAD SHX Text
INTERIM KITCHEN EQUIPMENT PLAN AND SCHEDULE - AREA B
AutoCAD SHX Text Q106C
AutoCAD SHX Text
INTERIM KITCHEN EQUIPMENT PLAN AND SCHEDULE - AREA C
AutoCAD SHX Text
CIVIL
AutoCAD SHX Text
CU101
AutoCAD SHX Text
CIVIL UTILITIES SITE PLAN
AutoCAD SHX Text
PL100
AutoCAD SHX Text
TEMPORARY KITCHEN PLUMBING PLAN
AutoCAD SHX Text
PL200
AutoCAD SHX Text
ENLARGED TEMPORARY KITCHEN PIPING PLAN
AutoCAD SHX Text
PL301
AutoCAD SHX Text
GRAVITY PIPING ISOMETRIC RISER DIAGRAM
AutoCAD SHX Text
PL302
AutoCAD SHX Text
PRESSURE PIPING ISOMETRIC RISER DIAGRAM
AutoCAD SHX Text
FP102
AutoCAD SHX Text
FIRE PROTECTION TEMPORARY KITCHEN ENLARGED VIEW
AutoCAD SHX Text
ES101
AutoCAD SHX Text
ELECTRICAL SITE PLAN
AutoCAD SHX Text
ED103
AutoCAD SHX Text
FIRST AND FIFTH FLOORS DEMOLITION - ELECTRICAL
AutoCAD SHX Text
EP102
AutoCAD SHX Text
FIRST AND FIFTH FLOORS - ELECTRICAL
AutoCAD SHX Text E502
AutoCAD SHX Text
DETAILS
AutoCAD SHX Text E604
AutoCAD SHX Text
KITCHEN FEEDER SCHEDULE
AutoCAD SHX Text
CU501
AutoCAD SHX Text
CIVIL UTILITIES TYPICAL DETAILS
AutoCAD SHX Text
CU502
AutoCAD SHX Text
CIVIL UTILITIES TYPICAL DETAILS
AutoCAD SHX Text
CU503
AutoCAD SHX Text
CIVIL UTILITIES TYPICAL DETAILS
AutoCAD SHX Text
PLAN NORTH
AutoCAD SHX Text
TRUE NORTH
AutoCAD SHX Text
PLAN NORTH
AutoCAD SHX Text
TRUE NORTH
ARCHITECTURAL LEGEND
MATERIAL LEGEND ARCHITECTURAL GENERAL NOTESGENERAL PROJECT NOTES ARCHITECTURAL ABBREVIATIONSUL DETAIL C-AJ-1254
UL DETAIL W-L-2038
ACCESSIBILITY REQUIREMENTS
FRONT APPROACHES
HINGE-SIDE APPROACHES
LATCH-SIDE APPROACHES
TYPICAL DETAILS
TYPICAL MOUNTING HEIGHTS
TYPICAL SIGNAGE MOUNTING HEIGHTS
LEGENDS ABBREVIATIONS AND
NOTES
G002
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
95% SUBMITTAL
FULLY SPRINKLERED
Phase
A/E RENOVATE KITCHEN
BUILDING 100
BAY PINES VAHCS, FLORIDA
516-15-105
12/18/2020 AT CC/SJ
AutoCAD SHX Text A
AutoCAD SHX Text + 0'-6"
AutoCAD SHX Text F.E.C.
AutoCAD SHX Text
FIRE EXTINGUISHER CABINET
AutoCAD SHX Text
ROOM NAME AND NUMBER
AutoCAD SHX Text
DOOR NUMBER
AutoCAD SHX Text
KEY NOTE
AutoCAD SHX Text
WINDOW TYPE
AutoCAD SHX Text
PARTITION TYPE
AutoCAD SHX Text
DETAIL CALLOUT
AutoCAD SHX Text
DETAIL NUMBER
AutoCAD SHX Text
SHEET WHERE DETAIL IS DRAWN
AutoCAD SHX Text
SECTION CALLOUT
AutoCAD SHX Text
VERTICAL ELEVATION
AutoCAD SHX Text
COLUMN CENTERLINE DESIGNATION
AutoCAD SHX Text
DEMOLITION NOTE
AutoCAD SHX Text
SECTION NUMBER
AutoCAD SHX Text
SHEET WHERE SECTION IS DRAWN
AutoCAD SHX Text
EXTERIOR ELEVATION CALLOUT
AutoCAD SHX Text
ELEVATION NUMBER
AutoCAD SHX Text
SHEET WHERE ELEVATION IS DRAWN
AutoCAD SHX Text
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
NAME
AutoCAD SHX Text
AutoCAD SHX Text A401
AutoCAD SHX Text
AutoCAD SHX Text A301
AutoCAD SHX Text
AutoCAD SHX Text A201
AutoCAD SHX Text
AutoCAD SHX Text
GA4
AutoCAD SHX Text
EARTH
AutoCAD SHX Text
GRAVEL
AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
MORTAR, STUCCO CEMENT PLASTER
AutoCAD SHX Text
CONCRETE MASONRY UNIT
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
PLAN
AutoCAD SHX Text
STEEL
AutoCAD SHX Text
INSULATION RIGID
AutoCAD SHX Text
INSULATION BATT
AutoCAD SHX Text
BRICK
AutoCAD SHX Text
WOOD (ROUGH)
AutoCAD SHX Text
WOOD FINISH
AutoCAD SHX Text
INTERIOR ELEVATION CALLOUT
AutoCAD SHX Text
ELEVATION NUMBER
AutoCAD SHX Text
SHEET WHERE ELEVATION IS DRAWN
AutoCAD SHX Text A401
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A. DIMENSIONS, UNLESS OTHERWISE INDICATED, ARE TO: DIMENSIONS, UNLESS OTHERWISE INDICATED, ARE TO: FACE OF EXISTING WALL SURFACE FACE OF NEW MASONRY FACE OF NEW WALL STUDS TOP OF SLAB TOP OF MASONRY ALIGN NEW WALLS WITH EXISTING WHERE NOT OTHERWISE INDICATED. B. COORDINATE WITH ELECTRICAL, HVAC, PLUMBING, AND COORDINATE WITH ELECTRICAL, HVAC, PLUMBING, AND FIRE PROTECTION DRAWINGS FOR ADDITIONAL REQUIREMENTS. COORDINATE DUCT, CONDUIT, AND PIPE OPENINGS IN SLABS, ROOF, AND WALLS. COORDINATE DUCT, CONDUIT, AND PIPE ROUTING ABOVE CEILINGS. WHERE NEW HOLES IN EXISTING WALLS AND SLABS ARE CREATED FOR CONDUIT, DUCT, OR PIPE PENETRATIONS COORDINATE SIZE AND LOCATION OF SUCH WORK WITH INSTALLERS OF SUCH CONDUIT, PIPE, DUCT, AND EQUIPMENT. PATCH HOLES CAUSED BY THE REMOVAL OF EQUIPMENT, PIPING, CONDUIT, DUCT, GRILLES, ETC. WITH MATERIALS MATCHING EXISTING SLAB OR WALL IN STRUCTURE, MATERIAL, THICKNESS, ALIGNMENT, GRADES, AND QUALITY. C. COORDINATE AND PROVIDE SOLID FIRE RETARDANT COORDINATE AND PROVIDE SOLID FIRE RETARDANT TREATED WOOD BLOCKING OR METAL BACKER PLATE FOR WALL HOOKS, BRACKETS, GRAB BARS, COMPUTER MONITORS, TELEVISION WALL BRACKETS, HANDRAILS, GUARDRAILS, DISPLAYS, ACCESSORIES, ETC. COORDINATE LOCATIONS WITH COR FOR GOVERNMENT PROVIDED EQUIPMENT/ACCESSORIES. D. `PROVIDE' IS DEFINED AS PROVIDING MATERIALS, `PROVIDE' IS DEFINED AS PROVIDING MATERIALS, DELIVERY, STORAGE, HANDLING, INSTALLATION, ADJUSTMENT, AND CLEANING FOR THE ITEM INDICATED. E. SEAL PIPE PENETRATIONS THROUGH SLABS, MASONRY, SEAL PIPE PENETRATIONS THROUGH SLABS, MASONRY, SMOKE RATED PARTITIONS AND FIRE-RATED PARTITIONS WITH THE APPROPRIATE FIRESTOP TO MAINTAIN THE RATING OF THE WALL OR SLAB. SUBMIT CUT SHEETS AND SPECIFICATIONS TO THE COR FOR APPROVAL PRIOR TO INSTALLATION. PROVIDE UL LISTED ASSEMBLIES. F. COORDINATE CONTRACTOR DUMPSTER LOCATION WITH COORDINATE CONTRACTOR DUMPSTER LOCATION WITH GOVERNMENT. DUMPSTER LOCATION TO BE IDENTIFIED PRIOR TO BIDDING. G. SKIM COAT ALL DAMAGED EXISTING WALL SURFACES SKIM COAT ALL DAMAGED EXISTING WALL SURFACES THAT REQUIRE PAINTING. H. PRIME CONTRACTOR TO HIRE AN ABATEMENT PRIME CONTRACTOR TO HIRE AN ABATEMENT SUB-CONTRACTOR TO PERFORM ASBESTOS ABATEMENT WORK. ABATEMENT WORK MUST BE COORDINATED WITH THE COR PRIOR TO START OF ABATEMENT. GIVE THE COR A MINIMUM OF 14 DAYS NOTICE BEFORE START OF PLANNED ABATEMENT ACTIVITIES. SEE ABATEMENT SPECIFICATIONS. I. COORDINATE DEMOLITION AND NEW WORK AMONG COORDINATE DEMOLITION AND NEW WORK AMONG DISCIPLINES. J. REMOVED MATERIALS WHICH ARE INDICATED TO BE REMOVED MATERIALS WHICH ARE INDICATED TO BE TURNED OVER TO THE COR SHALL BE DELIVERED BY THE CONTRACTOR TO A PLACE INDICATED BY THE COR IF APPLICABLE. K. REMOVE COMPLETELY ALL MATERIALS AS INDICATED REMOVE COMPLETELY ALL MATERIALS AS INDICATED ON THE DRAWINGS AND AS REQUIRED FOR NEW CONSTRUCTION. EDGES AND FACES OF DEMOLISHED AREAS SHALL BE REPAIRED TO ACCEPT NEAT INSTALLATION OF NEW CONSTRUCTION OR FINISHES. WHERE EXISTING MATERIALS ARE TO BE REPLACED (WALLS, INSULATION, FLOORING, ETC.) EXISTING MATERIALS, ADHESIVES, ETC. SHALL BE REMOVED AND EXPOSED SURFACES SHALL BE PREPARED AS RECOMMENDED BY MANUFACTURER PRIOR TO INSTALLATION OF NEW MATERIALS. L. PREVENT DAMAGE TO MATERIALS AND FINISHES TO PREVENT DAMAGE TO MATERIALS AND FINISHES TO REMAIN (PAINT, WALLCOVERING, BASE, CEILINGS, CHAIR RAILS, ETC.). REPAIR DAMAGES FROM CONSTRUCTION ACTIVITIES TO EXISTING ITEMS TO REMAIN, AT NO ADDITIONAL COST TO THE OWNER. WHERE SUCH EXPOSED MATERIALS OR FINISHES TO REMAIN ARE DAMAGED OR LEFT WITH HOLES BY CONSTRUCTION ACTIVITIES, REPAIR, REPLACE, OR INFILL SUCH MATERIALS AND FINISHES TO MATCH EXISTING IN MATERIAL, SIZE, ALIGNMENT, FINISH, COLOR, TEXTURE, AND QUALITY. EXTEND NEW FINISHES TO LOGICAL EDGES (CHANGE OF MATERIAL OR CORNERS). ALL SHALL BE REPLACED OR REPAIRED TO MATCH OR EXCEED THE QUALITY THAT EXISTED BEFORE DAMAGE.
AutoCAD SHX Text A. THE CONTRACTOR SHALL NOT ORDER OR INSTALL ANY THE CONTRACTOR SHALL NOT ORDER OR INSTALL ANY MATERIALS OR EQUIPMENT UNTIL SUBMITTALS FOR SUCH HAVE BEEN APPROVED. B. THE CONTRACTOR WILL BE RESPONSIBLE FOR THE CONTRACTOR WILL BE RESPONSIBLE FOR ACQUIRING I.D. BADGES FOR EACH MEMBER OF HIS WORK FORCE. VALID FORMS OF I.D. ARE REQUIRED TO RECEIVE BADGES. COORDINATE WITH COR. C. ANY SMOKE DETECTORS HAVING ANY POTENTIAL FOR ANY SMOKE DETECTORS HAVING ANY POTENTIAL FOR EXPOSURE TO CONSTRUCTION SMOKE, DUST, AND DEBRIS SHALL BE SUITABLY PROTECTED TO PREVENT ACCIDENTAL ALARM. ALL SUCH ACTION MUST BE FIRST COORDINATED AND CLEARED WITH COR. ALL FIRE ALARM DEVICES SHALL BE ACTIVE WHENEVER CONTRACTOR'S FORCES ARE NOT PRESENT IN WORK AREA. D. THE CONTRACTOR MUST PROVIDE A WRITTEN FIRE THE CONTRACTOR MUST PROVIDE A WRITTEN FIRE SAFETY CHECKLIST AT THE END OF EVERY WORK DAY TO THE COR CERTIFYING THAT ALL WORK AREAS HAVE BEEN SURVEYED AND FOUND TO BE SECURE, SAFE, AND FREE OF ANY FLAMMABLE LIQUIDS. E. CONTRACTOR SHALL COORDINATE ONLY WITH THE COR CONTRACTOR SHALL COORDINATE ONLY WITH THE COR AND CONTRACTING OFFICER. F. CONTRACTOR SHALL FIELD VERIFY DIMENSIONS & ALL CONTRACTOR SHALL FIELD VERIFY DIMENSIONS & ALL EXISTING CONDITIONS PRIOR TO PROCEEDING WITH THE WORK. EXISTING CONDITIONS ARE BASED ON GOVERNMENT FURNISHED EXISTING DRAWINGS AND LIMITED FIELD INVESTIGATION. NOTIFY COR OF ANY DISCREPANCIES. G. ALL FINISH COLORS TO BE SELECTED BY COR WHERE ALL FINISH COLORS TO BE SELECTED BY COR WHERE NOT OTHERWISE INDICATED. H. SEAL ALL PLATES, COVERS, DEVICES, AND GENERAL SEAL ALL PLATES, COVERS, DEVICES, AND GENERAL WALL AND CEILING PENETRATIONS IN ALL NEW SPACES, TYPICAL. I. PROVIDE MINIMUM (1) 24" x 24" ACCESS PANELS IN PROVIDE MINIMUM (1) 24" x 24" ACCESS PANELS IN HARD CEILINGS WHERE DUCTS AND DAMPERS OR OTHER PIPES REQUIRE ACCESS. COORDINATE EXACT LOCATION W/COR. PROVIDE ADDITIONAL ACCESS PANELS IN CHASES AT EACH FLOOR TO ACCESS DUCTS AND DAMPERS. J. OPEN EXISTING DRYWALL AS NECESSARY TO INSTALL OPEN EXISTING DRYWALL AS NECESSARY TO INSTALL NEW DUCTS, PLUMBING AND ELECTRICAL DEVICES. RECONSTRUCT WALL AND FINISH TO MATCH EXISTING. ADD ACCESS PANELS WHERE INDICATED.
AutoCAD SHX Text
AIR CONDITIONING
AutoCAD SHX Text
ACOUSTICAL CEILING TILE
AutoCAD SHX Text
ABOVE FINISH FLOOR
AutoCAD SHX Text
ALUMINUM
AutoCAD SHX Text
BATT INSULATION
AutoCAD SHX Text
BOTTOM OF
AutoCAD SHX Text
CEMENTITIOUS BACKER BOARD
AutoCAD SHX Text
COLD-FORMED METAL FRAMING
AutoCAD SHX Text
CORNER GUARD
AutoCAD SHX Text
CENTERLINE
AutoCAD SHX Text
CONCRETE MASONRY UNIT
AutoCAD SHX Text
CASED OPENING
AutoCAD SHX Text
COMMUNICATION
AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
CONTINUOUS
AutoCAD SHX Text
CONTRACTING OFFICER'S REPRESENTATIVE
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text
CERAMIC TILE BASE
AutoCAD SHX Text
CARPET
AutoCAD SHX Text
DIAMETER
AutoCAD SHX Text
DRINKING FOUNTAIN
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
EQUAL
AutoCAD SHX Text
EXPOSED STRUCTURE
AutoCAD SHX Text
ET CETERA
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
EXPOSED
AutoCAD SHX Text
FACTORY FINISH
AutoCAD SHX Text
FLOOR DRAIN
AutoCAD SHX Text
FIRE EXTINGUISHER CABINET
AutoCAD SHX Text
FINISHED FLOOR
AutoCAD SHX Text
FINISH
AutoCAD SHX Text
FLOOR
AutoCAD SHX Text
FACE OF
AutoCAD SHX Text
FIELD VERIFY (PRIOR TO ORDERING OR CUTTING)
AutoCAD SHX Text
GAGE
AutoCAD SHX Text
GRANITE
AutoCAD SHX Text
GYPSUM WALL BOARD
AutoCAD SHX Text
HANDICAPPED
AutoCAD SHX Text
HOLLOW METAL
AutoCAD SHX Text
HIGH-PRESSURE DECORATIVE LAMINATE
AutoCAD SHX Text
HEATING VENTILATION AND AIR-CONDITIONING
AutoCAD SHX Text
MATERIAL
AutoCAD SHX Text
MAXIMUM
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
MINIMUM
AutoCAD SHX Text
MASONRY OPENING
AutoCAD SHX Text
METAL
AutoCAD SHX Text
NOT IN CONTRACT
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
ON CENTER
AutoCAD SHX Text
OPPOSITE HAND
AutoCAD SHX Text
PLASTER
AutoCAD SHX Text
PLASTIC LAMINATE
AutoCAD SHX Text
PRESSURE TREATED/ PORCELAIN TILE
AutoCAD SHX Text
PAIR
AutoCAD SHX Text
PAINT
AutoCAD SHX Text
QUARRY TILE
AutoCAD SHX Text
RESILIENT BASE
AutoCAD SHX Text
REFRIGERATOR
AutoCAD SHX Text
REQUIRED
AutoCAD SHX Text
RESINOUS FLOORING
AutoCAD SHX Text
RESINOUS EPOXY WALL - CEILING
AutoCAD SHX Text
ROUGH OPENING
AutoCAD SHX Text
RUBBER FLOORING
AutoCAD SHX Text
SEALED HIGH BUILD GLAZED COATING
AutoCAD SHX Text
SOLID CORE WOOD
AutoCAD SHX Text
SIMILAR
AutoCAD SHX Text
SPECIAL FACED
AutoCAD SHX Text
STAINLESS STEEL
AutoCAD SHX Text
STEEL
AutoCAD SHX Text
SUBSTRATE
AutoCAD SHX Text
SHEET VINYL
AutoCAD SHX Text
SOLID VINYL TILE
AutoCAD SHX Text
TELEPHONE
AutoCAD SHX Text
TOP OF
AutoCAD SHX Text
TYPICAL
AutoCAD SHX Text
UNLESS NOTED OTHERWISE
AutoCAD SHX Text
VINYL COMPOSITION TILE
AutoCAD SHX Text
WOOD
AutoCAD SHX Text
WELDED SEAM SHEET FLOORING (HEAT WELDED WITH ROD)
AutoCAD SHX Text
AC
AutoCAD SHX Text
ACT
AutoCAD SHX Text
AFF
AutoCAD SHX Text
ALUM
AutoCAD SHX Text
BATT
AutoCAD SHX Text
BO
AutoCAD SHX Text
CBB
AutoCAD SHX Text
CFMF
AutoCAD SHX Text
CG
AutoCAD SHX Text C
AutoCAD SHX Text
CMU
AutoCAD SHX Text
CO
AutoCAD SHX Text
COMM
AutoCAD SHX Text
CONC
AutoCAD SHX Text
CONT
AutoCAD SHX Text
COR
AutoCAD SHX Text
CT
AutoCAD SHX Text
CTB
AutoCAD SHX Text
CP
AutoCAD SHX Text
DIA
AutoCAD SHX Text
DF
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
EQ
AutoCAD SHX Text
ES
AutoCAD SHX Text
ETC
AutoCAD SHX Text
EXIST
AutoCAD SHX Text
EXP
AutoCAD SHX Text
FAC FIN
AutoCAD SHX Text
FD
AutoCAD SHX Text
FEC
AutoCAD SHX Text
FF
AutoCAD SHX Text
FIN
AutoCAD SHX Text
FLR
AutoCAD SHX Text
FO
AutoCAD SHX Text
FV
AutoCAD SHX Text
GA
AutoCAD SHX Text
GRA
AutoCAD SHX Text
GWB
AutoCAD SHX Text
HC
AutoCAD SHX Text
HM
AutoCAD SHX Text
HPDL
AutoCAD SHX Text
HVAC
AutoCAD SHX Text
MATL
AutoCAD SHX Text
MAX
AutoCAD SHX Text
MECH
AutoCAD SHX Text
MFR
AutoCAD SHX Text
MIN
AutoCAD SHX Text
MO
AutoCAD SHX Text
MTL
AutoCAD SHX Text
NIC
AutoCAD SHX Text
NTS
AutoCAD SHX Text
OC
AutoCAD SHX Text
OH
AutoCAD SHX Text
PLS
AutoCAD SHX Text
PLAM
AutoCAD SHX Text
PT
AutoCAD SHX Text
PR
AutoCAD SHX Text P
AutoCAD SHX Text
QT
AutoCAD SHX Text
RB
AutoCAD SHX Text
REF
AutoCAD SHX Text
REQ'D
AutoCAD SHX Text
RES
AutoCAD SHX Text
RES-W
AutoCAD SHX Text
RO
AutoCAD SHX Text
RF
AutoCAD SHX Text
SC
AutoCAD SHX Text
SCW
AutoCAD SHX Text
SIM
AutoCAD SHX Text
SP
AutoCAD SHX Text
SS
AutoCAD SHX Text
ST
AutoCAD SHX Text
SUBS
AutoCAD SHX Text
SV
AutoCAD SHX Text
SVT
AutoCAD SHX Text
TELE
AutoCAD SHX Text
TO
AutoCAD SHX Text
TYP
AutoCAD SHX Text
UNO
AutoCAD SHX Text
VCT
AutoCAD SHX Text
WD
AutoCAD SHX Text
WSF
AutoCAD SHX Text L
AutoCAD SHX Text
SEALED CONCRETE
AutoCAD SHX Text
SCONC
AutoCAD SHX Text
CONTROL JOINT
AutoCAD SHX Text
CJ
AutoCAD SHX Text
GALVANIZED METAL STUD(S)
AutoCAD SHX Text
GMS
AutoCAD SHX Text NOTE: ANY UL ASSEMBLY MEETING CRITERIA MAY ANY UL ASSEMBLY MEETING CRITERIA MAY BE UTILIZED. ASSEMBLIES INDICATED ON THIS SHEET ARE FOR INFORMATION ONLY.
AutoCAD SHX Text
ACCESSORY TYPE
AutoCAD SHX Text A
AutoCAD SHX Text
SOLID SURFACE MATERIAL
AutoCAD SHX Text
SSM
AutoCAD SHX Text ALL WORK SHALL COMPLY WITH FEDERAL ABA, LOCAL, AND STATE ACCESSIBILITY CODES AND REQUIREMENTS.
AutoCAD SHX Text
TYP DOOR LOCATION
AutoCAD SHX Text
SEE DOOR SCHEDULE
AutoCAD SHX Text
DOOR LOCATIONS
AutoCAD SHX Text
1'-0" IF DOOR HAS BOTH A CLOSER AND A LATCH
AutoCAD SHX Text
OPTION 1
AutoCAD SHX Text
OPTION 1
AutoCAD SHX Text
OPTION 1
AutoCAD SHX Text
OPTION 1
AutoCAD SHX Text
OPTION 2
AutoCAD SHX Text
OPTION 2
AutoCAD SHX Text
OPTION 2
AutoCAD SHX Text
OPTION 2
AutoCAD SHX Text
USE EITHER OPTION 1 OR OPTION 2
AutoCAD SHX Text ALL ACCESSIBLE DOOR ASSEMBLIES SHALL BE CONSTRUCTED TO MEET THE INDICATED MINIMUM CLEARANCES AS APPLICABLE.
AutoCAD SHX Text 4'-6"
AutoCAD SHX Text 4'-6"
AutoCAD SHX Text 4'-0"
AutoCAD SHX Text 4'-0"
AutoCAD SHX Text
W/ CLOSER AND LATCH
AutoCAD SHX Text PROVIDE ACCESSIBILITY PER VA/UFAS BARRIER FREE DESIGN GUIDE (PG 18-13) AND ABAAS.
AutoCAD SHX Text PROVIDE BLOCKING AS REQUIRED AT ALL WALL-MOUNTED EQUIPMENT, FIXTURES AND ACCESSORIES.
AutoCAD SHX Text
SOAP DISPENSER
AutoCAD SHX Text
GARMENT HOOK
PAPER TOWEL DISPENSER
AutoCAD SHX Text
DISPENSER OPENING
AutoCAD SHX Text
FIRE EXTINGUISHER CABINET
AutoCAD SHX Text
HANDLE
AutoCAD SHX Text
SEE PLAN
AutoCAD SHX Text
SEE PLAN
AutoCAD SHX Text
SEE PLAN
AutoCAD SHX Text
PROVIDE BLOCKING, ANCHORAGE AND MOUNTING AS REQUIRED AT ALL SIGNAGE LOCATIONS.
SEE PLAN
E
E
E
E
E
DO
W
N
DO
W N
DOWN DOWN DOWN DOWN
DO
W
N
DO
W N
DO
W
N
DO
W N
DO
W
N
DO
W N
W
AL
K-
IN
F
RE
EZ
ER
W
AL
K-
IN
C
OO
LE
R
M8
M8
M6
M7
M8
CA
RT
W
AS
H
M7
EX LIGHT POLE
TO BE REMOVED
EX SIGNS TO
BE REMOVED
EX
" W
AT
ER
M
AI
N
(T
YP
EX
S
AN
IT
AR
Y
M
AI
N (T
YP
PROP. 3
5 L
F 6"
DIP
SANITARY SERVICE LI
NE
(TYP.) (
0.5
% SLO
PE)
CONNECT TO EX
SANITARY
MANHOLE (TYP.)
TAP TO EX 8"
WATER MAIN (TYP.)
PROP. CORPORATION
STOP
PROP. 32 LF 2" PVC
WATER SERVICE
LINE (TYP.)
RIM 9.94'
S 10" 4.49' W 8" 4.39' N 10" 4.37'
NE 6" 6.90'
INV. EL = 6.9175'
PROP. 23 LF 2" PVC
WATER SERVICE
LINE (TYP.)
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
95% SUBMITTAL
FULLY SPRINKLERED
Phase
A/E RENOVATE KITCHEN
BUILDING 100
BAY PINES VAHCS, FLORIDA
516-15-105
12/18/2020 MRI NDP
Matthew R. Ivie, P.E. #86205
Ayres Associates Inc
8875 Hidden River Parkway, Suite 200
Tampa, FL 33637
813-978-8688
CIVIL UTILITIES
SITE PLAN
GRADING NOTESGENERAL CONSTRUCTION NOTES
TREE PROTECTION NOTES
EROSION & POLLUTION CONTROL NOTESTESTING AND INSPECTION REQUIREMENTS :
ABBREVIATIONS
SEPARATION REQUIREMENTS
WATER MAIN INSTALLATION NOTES
SURVEY NOTES
LEGEND
KEY MAP
CU101
AutoCAD SHX Text
1. PROTECTIVE BARRICADES SHALL BE PLACED AROUND ALL TREES GREATER THAN 8" DIAMETER DURING PROTECTIVE BARRICADES SHALL BE PLACED AROUND ALL TREES GREATER THAN 8" DIAMETER DURING SITE CLEARING, AND SHALL REMAIN IN PLACE UNTIL LAND ALTERATION, SITE CLEARING AND CONSTRUCTION ACTIVITIES ARE COMPLETE. BARRICADES SHALL BE PER DETAIL 6 ON SHEET CU501. THE LOW HANGING BRANCHES OF TREES MUST ALSO BE PROTECTED. 2. REQUIRED TREE BARRICADES AND EROSION CONTROL MEASURES MUST REMAIN INTACT THROUGHOUT REQUIRED TREE BARRICADES AND EROSION CONTROL MEASURES MUST REMAIN INTACT THROUGHOUT CONSTRUCTION. 3. THE CONTRACTOR IS REQUIRED TO PREVENT DAMAGE TO TREES WHICH ARE TO REMAIN. THE THE CONTRACTOR IS REQUIRED TO PREVENT DAMAGE TO TREES WHICH ARE TO REMAIN. THE CONTRACTOR SHALL BE LIABLE FOR ALL DAMAGE OF TREES THAT ARE DESIGNATED TO BE SAVED DURING CONSTRUCTION. SPECIAL CARE IS REQUIRED TO PREVENT DAMAGE TO TREES WHICH ARE TO REMAIN. 4. INSTALLATION OF ARTIFICIAL BARRIERS SUCH AS PROTECTIVE BARRICADES, FENCES, POSTS, OR WALLS INSTALLATION OF ARTIFICIAL BARRIERS SUCH AS PROTECTIVE BARRICADES, FENCES, POSTS, OR WALLS SHALL NOT DESTROY OR IRREVERSIBLY HARM THE ROOT SYSTEM OF PROTECTED TREES. POST HOLES AND TRENCHES LOCATED CLOSE TO PROTECTED TREES SHALL BE ADJUSTED TO AVOID DAMAGE TO MAJOR ROOTS. 5. ALL ROOTS TO BE REMOVED DURING THE SITE CLEARING PHASE SHALL BE ROOT PRUNED AND ALL ROOTS TO BE REMOVED DURING THE SITE CLEARING PHASE SHALL BE ROOT PRUNED AND TRENCHED AT THE CONSTRUCTION LINE BY A CERTIFIED ARBORIST. 6. A TWO-INCH (2") LAYER OF MULCH SHALL BE APPLIED OVER THE SURFACE OF EXPOSED ROOTS OF A TWO-INCH (2") LAYER OF MULCH SHALL BE APPLIED OVER THE SURFACE OF EXPOSED ROOTS OF PROTECTED TREES DURING THE SITE CLEARING PHASE. 7. ALL TRIMMING OF PROTECTED TREES AND GRAND TREES SHALL BE DONE BY A QUALIFIED, LICENSED ALL TRIMMING OF PROTECTED TREES AND GRAND TREES SHALL BE DONE BY A QUALIFIED, LICENSED TREE SERVICE DURING DEVELOPMENT, AND SHALL BE PRUNED IN ACCORDANCE WITH THE AMERICAN NATIONAL STANDARD INSTITUTE (ANSI) A-300 PRUNING STANDARDS. 8. IT SHALL BE UNLAWFUL TO REMOVE VEGETATION BY GRUBBING OR TO PLACE SOIL DEPOSITS, IT SHALL BE UNLAWFUL TO REMOVE VEGETATION BY GRUBBING OR TO PLACE SOIL DEPOSITS, DEBRIS, SOLVENTS, CONSTRUCTION MATERIAL, MACHINERY OR OTHER EQUIPMENT OF ANY KIND WITHIN DRIP LINE OF A TREE TO REMAIN ON SITE UNLESS OTHERWISE APPROVED BY THE COR.
AutoCAD SHX Text
1. SLOPES SHALL NOT BE STEEPER THAN ONE (1) VERTICAL TO FOUR (4) HORIZONTAL IN GENERAL SLOPES SHALL NOT BE STEEPER THAN ONE (1) VERTICAL TO FOUR (4) HORIZONTAL IN GENERAL OPEN LAWN AND OTHER GRASSED AREAS. STEEPER SLOPES WILL BE PERMITTED ONLY ON A CASE-BY-CASE BASIS WHERE SPECIAL NEED WARRANTS. TOPS AND BOTTOMS OF BANKS AND OTHER BREAK POINTS SHALL BE ROUNDED TO PROVIDE A SMOOTH TRANSITION. 2. ALL DELETERIOUS SUBSURFACE MATERIAL (I.E. MULCH, PEAT, BURIED DEBRIS) IS TO BE ALL DELETERIOUS SUBSURFACE MATERIAL (I.E. MULCH, PEAT, BURIED DEBRIS) IS TO BE EXCAVATED IN ACCORDANCE WITH THESE PLANS AND SPECIFICATIONS. SPOIL MATERIAL SHALL NOT SPOIL MATERIAL SHALL NOT BE TAKEN OFF SITE. AREAS ARE TO BE BACKFILLED WITH APPROVED MATERIALS AND COMPACTED AREAS ARE TO BE BACKFILLED WITH APPROVED MATERIALS AND COMPACTED AS SHOWN ON THESE PLANS AND SPECIFICATIONS. CONTRACTOR TO COORDINATE WITH VA/COR LOCATION FOR SPOILED DIRT. REMAINING DEBRIS TO BE REMOVED FROM SITE IN ACCORDANCE WITH SPECIFICATIONS. 3. EXCESS EXCAVATION AND MATERIAL NOT SUITABLE FOR BACKFILL AND EMBANKMENT OPERATIONS EXCESS EXCAVATION AND MATERIAL NOT SUITABLE FOR BACKFILL AND EMBANKMENT OPERATIONS SHALL BE REMOVED AND PROPERLY DISPOSED FROM THE SITE. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING EXCAVATIONS AGAINST COLLAPSE THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING EXCAVATIONS AGAINST COLLAPSE AND WILL PROVIDE BRACING, SHEETING OR SHORING AS NECESSARY ACCORDING TO OSHA REQUIREMENTS. DEWATERING METHODS SHALL BE USED AS REQUIRED TO KEEP TRENCHES DRY WHILE PIPE AND APPURTENANCES ARE BEING PLACED. 5. ALL NECESSARY FILL AND EMBANKMENT THAT IS PLACED DURING CONSTRUCTION SHALL CONFORM ALL NECESSARY FILL AND EMBANKMENT THAT IS PLACED DURING CONSTRUCTION SHALL CONFORM TO SPECIFICATIONS AND BE PLACED AND COMPACTED ACCORDING TO PLANS AND SPECIFICATIONS. 6. PROPOSED SPOT ELEVATIONS REPRESENT FINISHED PAVEMENT OR GROUND SURFACE GRADE PROPOSED SPOT ELEVATIONS REPRESENT FINISHED PAVEMENT OR GROUND SURFACE GRADE UNLESS OTHERWISE NOTED ON DRAWINGS. 7. IT MAY BE NECESSARY TO FIELD ADJUST UTILITY ELEVATIONS TO PRESERVE THE ROOT SYSTEMS IT MAY BE NECESSARY TO FIELD ADJUST UTILITY ELEVATIONS TO PRESERVE THE ROOT SYSTEMS OF TREES SHOWN TO BE SAVED. CONTRACTOR TO COORDINATE WITH COR PRIOR TO ANY ELEVATION CHANGES. 8. CONTRACTOR SHALL TRIM, TACK AND MATCH EXISTING PAVEMENT AT LOCATIONS WHERE NEW CONTRACTOR SHALL TRIM, TACK AND MATCH EXISTING PAVEMENT AT LOCATIONS WHERE NEW PAVEMENT MEETS EXISTING PAVEMENT. 9. THE CONTRACTOR WILL STABILIZE BY SOD DISTURBED GRASS AREAS WITHIN ONE WEEK THE CONTRACTOR WILL STABILIZE BY SOD DISTURBED GRASS AREAS WITHIN ONE WEEK FOLLOWING CONSTRUCTION OF THE UTILITY SYSTEMS AND PAVEMENT AREAS. CONTRACTOR SHALL MAINTAIN SUCH AREAS UNTIL FINAL ACCEPTANCE BY THE COR. 10. THE CONTRACTOR SHALL MAINTAIN VERTICAL AND HORIZONTAL ROADWAY SLOPES.THE CONTRACTOR SHALL MAINTAIN VERTICAL AND HORIZONTAL ROADWAY SLOPES.
AutoCAD SHX Text
1. LOCATIONS, ELEVATIONS, AND DIMENSIONS OF EXISTING UTILITIES, STRUCTURES AND OTHER LOCATIONS, ELEVATIONS, AND DIMENSIONS OF EXISTING UTILITIES, STRUCTURES AND OTHER FEATURES ARE SHOWN ACCORDING TO THE BEST INFORMATION AVAILABLE AT TIME OF PREPARATION OF THESE PLANS. THE CONTRACTOR SHALL VERIFY THE LOCATIONS, ELEVATIONS, AND DIMENSIONS OF ALL EXISTING UTILITIES, STRUCTURES AND OTHER FEATURES AFFECTING THIS WORK PRIOR TO CONSTRUCTION. 2. THE CONTRACTOR SHALL CHECK PLANS FOR CONFLICTS AND DISCREPANCIES PRIOR TO THE CONTRACTOR SHALL CHECK PLANS FOR CONFLICTS AND DISCREPANCIES PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER'S REPRESENTATIVE (COR) OF ANY CONFLICT BEFORE PERFORMING ANY WORK IN THE AFFECTED AREA. 3. THE CONTRACTOR IS RESPONSIBLE FOR REPAIRING ANY DAMAGE TO EXISTING FACILITIES, ABOVE THE CONTRACTOR IS RESPONSIBLE FOR REPAIRING ANY DAMAGE TO EXISTING FACILITIES, ABOVE OR BELOW GROUND, THAT MAY OCCUR AS A RESULT OF THE WORK PERFORMED BY THE CONTRACTOR CALLED FOR IN THIS CONTRACT. 4. ALL WORK PERFORMED SHALL COMPLY WITH THE REGULATIONS AND ORDINANCES OF SOUTHWEST ALL WORK PERFORMED SHALL COMPLY WITH THE REGULATIONS AND ORDINANCES OF SOUTHWEST FLORIDA WATER MANAGEMENT DISTRICT (SWFWMD) AND ENVIRONMENTAL PROTECTION AGENCY (EPA). THE CONTRACTOR SHALL PREPARE NPDES/SWPPP DOCUMENTS AS REQUIRED. 5. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS ON ALL PRE-CAST AND MANUFACTURED ITEMS TO CONTRACTOR SHALL SUBMIT SHOP DRAWINGS ON ALL PRE-CAST AND MANUFACTURED ITEMS TO THE COR FOR APPROVAL. FAILURE TO OBTAIN APPROVAL BEFORE INSTALLATION MAY RESULT IN REMOVAL AND REPLACEMENT AT CONTRACTOR'S EXPENSE. 6. SIGNS AND BARRICADES TO BE ACCORDING TO FDOT DESIGN STANDARDS; INDEXES 600 THRU SIGNS AND BARRICADES TO BE ACCORDING TO FDOT DESIGN STANDARDS; INDEXES 600 THRU 670 LATEST EDITION. FOR PEDESTRIAN CONTROL SEE INDEX 660. 7. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ESTABLISH BENCHMARKS (ELEV.), IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ESTABLISH BENCHMARKS (ELEV.), COORDINATES, CENTER LINES AND STATIONING AS REQUIRED TO CONSTRUCT THIS PROJECT. 8. ALL PIPES TO BE CONSTRUCTED WITH 3' MINIMUM COVER UNLESS OTHERWISE NOTED ON THE ALL PIPES TO BE CONSTRUCTED WITH 3' MINIMUM COVER UNLESS OTHERWISE NOTED ON THE PLANS. 9. TRENCH EXCAVATIONS SHALL BE PROTECTED AT ALL TIMES. IT IS ALSO TO BE STIPULATED THAT TRENCH EXCAVATIONS SHALL BE PROTECTED AT ALL TIMES. IT IS ALSO TO BE STIPULATED THAT IF TRENCHES ARE TO BE LEFT OPEN WHILE UNATTENDED FOR ANY REASON, OR BEYOND WORK HOURS, THEY SHALL BE BARRICADED ACCORDING TO OSHA AND VA SAFETY REQUIREMENTS INCLUDING 8' TALL STEEL BARRIER FENCING WITH MESH FABRIC ON ALL FENCING. NEW PIPES SHALL NOT BE LEFT OPEN IN TRENCH OVERNIGHT. THE CONTRACTOR SHALL CAP/SEAL PIPE ENDS TO PREVENT CONTAMINATION. 10. ALL ROCKS OR STONES SHALL BE REMOVED FROM THE BACKFILL MATERIAL ACCORDING TO ALL ROCKS OR STONES SHALL BE REMOVED FROM THE BACKFILL MATERIAL ACCORDING TO SPECIFICATIONS. 11. ALL PIPE LENGTHS ARE PLUS OR MINUS. PIPE MEASUREMENTS ARE TO CENTER OF STRUCTURES ALL PIPE LENGTHS ARE PLUS OR MINUS. PIPE MEASUREMENTS ARE TO CENTER OF STRUCTURES OR FITTINGS. 12. CONCRETE WORK SHALL HAVE A MINIMUM ULTIMATE COMPRESSIVE STRENGTH OF 4,000 PSI (28 CONCRETE WORK SHALL HAVE A MINIMUM ULTIMATE COMPRESSIVE STRENGTH OF 4,000 PSI (28 DAY STRENGTH), UNLESS OTHERWISE INDICATED. 13. CONTRACTOR TO COORDINATE WITH UTILITY SERVICE OWNERS THROUGH "SUNSHINE 811" SERVICE CONTRACTOR TO COORDINATE WITH UTILITY SERVICE OWNERS THROUGH "SUNSHINE 811" SERVICE AND THE COR. PRIOR TO ANY DIGGING. TO MINIMIZE DISRUPTION OF SERVICE CONTRACTOR SHALL COORDINATE WITH THE COR PRIOR TO ANY CONNECTION TO EXISTING UTILITY SYSTEMS. 14. HAND DIG AROUND EXISTING PIPE CROSSINGS. HAND DIG AROUND EXISTING PIPE CROSSINGS. 15. ALL AREAS DISTURBED BY CONSTRUCTION SHALL BE REPLACED TO EXISTING CONDITIONS OR ALL AREAS DISTURBED BY CONSTRUCTION SHALL BE REPLACED TO EXISTING CONDITIONS OR BETTER. 16. THE CONTRACTOR SHALL REMOVE ANY ASBESTOS PIPES FOUND DURING CONSTRUCTION USING THE CONTRACTOR SHALL REMOVE ANY ASBESTOS PIPES FOUND DURING CONSTRUCTION USING APPROPRIATE SAFETY MEASURES. 17. CONTRACTOR SHALL BE AWARE OF 8 INCH THICK CONCRETE BASE UNDER EXISTING ASPHALT. CONTRACTOR SHALL BE AWARE OF 8 INCH THICK CONCRETE BASE UNDER EXISTING ASPHALT. 18. CONTRACTOR SHALL ISOLATE AND FLUSH ALL NEW PIPING AND ASSOCIATED CONTRACTOR SHALL ISOLATE AND FLUSH ALL NEW PIPING AND ASSOCIATED FITTINGS/ACCESSORIES PRIOR TO CONNECTION TO NEW OR EXISTING WATER MAINS FOR A PERIOD OF NOT LESS THAN 12 HOURS. AFTER INITIAL FLUSHING IS COMPLETE, CONTRACTOR SHALL ADD APPROPRIATE NON-FOAMING RUST INHIBITORS TO SYSTEM AND CONTINUE FLUSHING FOR 12 HOURS. AFTER FLUSHING IS COMPLETE, SYSTEM SHALL BE DRAINED AND FILLED WITH CLEAN WATER. 19. UNDER NO CIRCUMSTANCE SHALL ANY OF THE FLUSHING LIQUID BE INTRODUCED IN THE UNDER NO CIRCUMSTANCE SHALL ANY OF THE FLUSHING LIQUID BE INTRODUCED IN THE EXISTING SYSTEM. 20. CONTRACTOR SHALL CAP ALL EXISTING SERVICE LINES AT TIE IN POINTS.
AutoCAD SHX Text
1. PROTECTION AND STABILIZATION OF ON-SITE SOIL STOCKPILES: FILL MATERIAL STOCKPILES SHALL PROTECTION AND STABILIZATION OF ON-SITE SOIL STOCKPILES: FILL MATERIAL STOCKPILES SHALL BE PROTECTED AT ALL TIMES BY ON-SITE DRAINAGE CONTROLS WHICH PREVENT EROSION OF THE STOCKPILED MATERIAL. CONTROL OF DUST FROM SUCH STOCKPILES IS REQUIRED, DEPENDING UPON THEIR LOCATION AND THE EXPECTED LENGTH OF TIME THE STOCKPILES WILL BE PRESENT. ALL STOCKPILED MATERIAL SHALL BE REMOVED PRIOR TO INSPECTION. CONTRACTOR TO COORDINATE WITH VA/COR LOCATION FOR ON-SITE STOCKPILES. 2. PROTECTION OF EXISTING STORM SEWER SYSTEMS WATER INLETS IN THE VICINITY OF THE PROJECT PROTECTION OF EXISTING STORM SEWER SYSTEMS WATER INLETS IN THE VICINITY OF THE PROJECT SHALL BE PROTECTED BY SEDIMENT TRAPS SUCH AS SECURED SEDIMENT FILTERS, SOD, AND STONE. WHICH SHALL BE MAINTAINED AND MODIFIED AS REQUIRED BY CONSTRUCTION PROGRESS, AND WHICH MUST BE APPROVED BY THE COR BEFORE INSTALLATION. THIS WILL BE MAINTAINED TO PREVENT DEGRADATION OF THE WATERS OF THE COUNTY & STATE. 3. EROSION/SEDIMENTATION CONTROL: CONTRACTOR IS TO PROVIDE EROSION CONTROL/SEDIMENTATION EROSION/SEDIMENTATION CONTROL: CONTRACTOR IS TO PROVIDE EROSION CONTROL/SEDIMENTATION BARRIER (SILTATION CURTAIN) PRIOR TO CONSTRUCTION TO PREVENT SILTATION OF ADJACENT PROPERTY, STREETS, STORM SEWERS AND WATERWAYS. IN ADDITION, CONTRACTOR SHALL PLACE GRAVEL ON GROUND IN AREAS WHERE CONSTRUCTION RELATED TRAFFIC IS TO ENTER AND EXIT SITE. EITHER BY NATURAL DRAINAGE OR BY VEHICULAR TRAFFIC, THE CONTRACTOR IS TO REMOVE AND CLEAN SAID EARTH TO THE SATISFACTION OF THE COR AND/OR AUTHORITIES. 4. IF WIND EROSION BECOMES SIGNIFICANT DURING CONSTRUCTION, THE CONTRACTOR SHALL STABILIZE IF WIND EROSION BECOMES SIGNIFICANT DURING CONSTRUCTION, THE CONTRACTOR SHALL STABILIZE THE AFFECTED AREA USING SPRINKLING, IRRIGATION OR OTHER ACCEPTABLE METHODS. 5. THE CONTRACTOR IS RESPONSIBLE FOR PREPARING A SWPPP AND FILE A N.O.I. WITH THE FDEP.THE CONTRACTOR IS RESPONSIBLE FOR PREPARING A SWPPP AND FILE A N.O.I. WITH THE FDEP.
AutoCAD SHX Text
1. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING APPLICABLE TESTING WITH THE COR. DURING THE THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING APPLICABLE TESTING WITH THE COR. DURING THE COURSE OF THE WORK, CONTRACTOR WILL SUBMIT COPIES OF ALL TEST RESULTS AND CERTIFICATIONS TO THE COR STATING THAT ALL REQUIREMENTS HAVE BEEN MET. TRENCH COMPACTION SHALL SATISFY THE REQUIREMENTS OF THE PINELLAS COUNTY STANDARD TECHNICAL SPECIFICATIONS FOR ROADWAY AND GENERAL CONSTRUCTION LATEST EDITION.
AutoCAD SHX Text FDOT = FLORIDA DEPARTMENT OF TRANSPORTATION = FLORIDA DEPARTMENT OF TRANSPORTATION FLORIDA DEPARTMENT OF TRANSPORTATION SWFWMD = SOUTHWEST FLORIDA WATER MANAGEMENT DISTRICT = SOUTHWEST FLORIDA WATER MANAGEMENT DISTRICT SOUTHWEST FLORIDA WATER MANAGEMENT DISTRICT SWPPP = STORM WATER POLLUTION PREVENTION PLAN = STORM WATER POLLUTION PREVENTION PLAN STORM WATER POLLUTION PREVENTION PLAN NOI = NOTICE OF INTENT = NOTICE OF INTENT NOTICE OF INTENT FDEP = FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION = FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION COR = CONTRACTING OFFICER'S REPRESENTATIVE = CONTRACTING OFFICER'S REPRESENTATIVE CONTRACTING OFFICER'S REPRESENTATIVE OSHA = OCCUPATIONAL SAFETY & HEALTH ADMINISTRATION = OCCUPATIONAL SAFETY & HEALTH ADMINISTRATION OCCUPATIONAL SAFETY & HEALTH ADMINISTRATION MES = MITERED END SECTION = MITERED END SECTION MITERED END SECTION LBR = LIMEROCK BEARING RATIO = LIMEROCK BEARING RATIO LIMEROCK BEARING RATIO EPA = ENVIRONMENTAL PROTECTION AGENCY = ENVIRONMENTAL PROTECTION AGENCY ENVIRONMENTAL PROTECTION AGENCY F&I = FURNISH AND INSTALL = FURNISH AND INSTALL FURNISH AND INSTALL DI = DUCTILE IRON = DUCTILE IRON DUCTILE IRON MJ = MECHANICAL JOINT = MECHANICAL JOINT MECHANICAL JOINT PVC = POLYVINYL CHLORIDE PIPE = POLYVINYL CHLORIDE PIPE POLYVINYL CHLORIDE PIPE F&I = FURNISH AND INSTALL = FURNISH AND INSTALL FURNISH AND INSTALL DI/MJ = DUCTILE IRON MECHANICAL JOINT = DUCTILE IRON MECHANICAL JOINT DUCTILE IRON MECHANICAL JOINT HDPE = HIGH DENSITY POLYETHYLENE= HIGH DENSITY POLYETHYLENEHIGH DENSITY POLYETHYLENE
AutoCAD SHX Text
1. VERTICAL SEPARATION BETWEEN UNDERGROUND WATER MAINS AND SANITARY OR STORM SEWERS, VERTICAL SEPARATION BETWEEN UNDERGROUND WATER MAINS AND SANITARY OR STORM SEWERS, AND WASTEWATER OR STORMWATER FORCE MAINS: NEW OR RELOCATED, UNDERGROUND WATER MAINS CROSSING ANY EXISTING OR PROPOSED PRESSURE-TYPE SANITARY SEWER, WASTEWATER OR STORMWATER FORCE MAINS SHALL BE LAID SO THE OUTSIDE OF THE WATER MAIN IS AT LEAST 18 INCHES ABOVE OR BELOW THE OUTSIDE OF THE OTHER PIPELINE. WATER MAIN TO BE ABOVE THE OTHER PIPELINE UNLESS NOTED OTHERWISE. NEW RELOCATED, UNDERGROUND WATER MAINS CROSSING ANY EXISTING OR PROPOSED PRESSURE-TYPE SANITARY SEWER, WASTEWATER OR STORMWATER FORCE MAIN SHALL HAVE ONE FULL LENGTH OF WATER MAIN PIPE CENTERED ABOVE OR BELOW THE OTHER PIPELINE SO THE WATER MAIN JOINTS WILL BE AS FAR AS POSSIBLE FROM THE OTHER PIPELINE. ALTERNATIVELY, AT SUCH CROSSINGS, THE PIPES SHALL BE ARRANGED SO THAT ALL WATER MAIN JOINTS ARE AT LEAST THREE FEET FROM ALL JOINTS IN STORM SEWERS AND STORMWATER FORCE MAINS AND AT LEAST SIX FEET FROM ALL JOINTS IN GRAVITY OR PRESSURE-TYPE SANITARY SEWERS AND WASTEWATER FORCE MAINS. 2. HORIZONTAL SEPARATION BETWEEN UNDERGROUND WATER MAINS AND SANITARY OR STORM HORIZONTAL SEPARATION BETWEEN UNDERGROUND WATER MAINS AND SANITARY OR STORM SEWERS, AND WASTEWATER OR STORMWATER FORCE MAINS: NEW OR RELOCATED, UNDERGROUND WATER MAINS SHALL BE LAID TO PROVIDE A HORIZONTAL DISTANCE OF AT LEAST THREE FEET BETWEEN THE OUTSIDE OF THE WATER MAIN AND THE OUTSIDE OF ANY EXISTING OR PROPOSED STORM SEWER, STORMWATER FORCE MAIN OR RIGHT OF WAY LINES. NEW OR RELOCATED, UNDERGROUND WATER MAINS SHALL BE LAID TO PROVIDE A HORIZONTAL DISTANCE OF AT LEAST TEN FEET BETWEEN OUTSIDE OF THE WATER MAIN AND THE OUTSIDE OF ANY EXISTING OR PROPOSED GRAVITY OR PRESSURE-TYPE SANITARY SEWER, OR WASTEWATER FORCE MAIN.
AutoCAD SHX Text
1. THE HORIZONTAL COORDINATES SHOWN HEREON ARE REFERENCED TO A GRID THE HORIZONTAL COORDINATES SHOWN HEREON ARE REFERENCED TO A GRID PROJECTION OF THE STATE PLANE COORDINATE SYSTEM OF FLORIDA WEST ZONE (NAD 83/2011). 2. THE ELEVATIONS DEPICTED HEREON ARE RELATIVE TO THE NORTH AMERICAN VERTICAL THE ELEVATIONS DEPICTED HEREON ARE RELATIVE TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (N.A.V.D. 88) BASED UPON THE FOLLOWING NATIONAL GEODETIC SURVEY BENCHMARKS: "AG0025" (ELEVATION = 9.12') AND "AG7419" (ELEVATION = 6.23')
AutoCAD SHX Text
PROPOSED WATER SERVICE LINE
AutoCAD SHX Text
PROPOSED SANITARY SERVICE LINE
AutoCAD SHX Text
PROPOSED CORPORATION STOP
AutoCAD SHX Text
EXISTING WATER MAIN
AutoCAD SHX Text
SET " IRON ROD (SURVEY TBM)58" IRON ROD (SURVEY TBM)
AutoCAD SHX Text
SIRC
AutoCAD SHX Text
1. PIPE PIPE A. ALL WATERMAIN SHALL BE C900 PVC PIPING WITH SIZE AS NOTED ON THE PLAN. PVC PIPING ALL WATERMAIN SHALL BE C900 PVC PIPING WITH SIZE AS NOTED ON THE PLAN. PVC PIPING SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND AWWA C605. PLACE SELECTED MATERIAL AND THOROUGHLY COMPACTED TO ONE FOOT ABOVE THE TOP OF THE PIPE. B. PER ANSI/AWWA C651-14, FLUSH AND SANITIZE NEWLY INSTALLED WATERMAIN PIPE. PER ANSI/AWWA C651-14, FLUSH AND SANITIZE NEWLY INSTALLED WATERMAIN PIPE. 2. TRACER WIRE TRACER WIRE A. INSTALL COPPER TRACER WIRE, NO. 14 AWG SOLID, SINGLE CONDUCTOR, INSULATED. INSTALL COPPER TRACER WIRE, NO. 14 AWG SOLID, SINGLE CONDUCTOR, INSULATED. B. INSTALL IN THE TRENCH WITH PIPING TO ALLOW LOCATION OF THE PIPE WITH ELECTRONIC INSTALL IN THE TRENCH WITH PIPING TO ALLOW LOCATION OF THE PIPE WITH ELECTRONIC DETECTORS. THE WIRE SHALL NOT BE SPIRALED AROUND THE PIPE NOR TAPED TO THE PIPE. C. WIRE CONNECTIONS ARE TO BE MADE BY STRIPPING THE INSULATION FROM THE WIRE AND WIRE CONNECTIONS ARE TO BE MADE BY STRIPPING THE INSULATION FROM THE WIRE AND SOLDERING WITH ROSIN CORE SOLDER PER ASTM 828. SOLDER JOINTS SHALL BE WRAPPED WITH RUBBER TAPE AND ELECTRICAL TAPE. D. AT LEAST EVERY 1000 FEET (300 M) PROVIDE A 5 POUND (2.3 KG) MAGNESIUM ANODE AT LEAST EVERY 1000 FEET (300 M) PROVIDE A 5 POUND (2.3 KG) MAGNESIUM ANODE ATTACHED TO THE MAIN TRACER WIRE BY SOLDER. THE SOLDER JOINT SHALL BE WRAPPED WITH RUBBER TAPE AND WITH ELECTRICAL TAPE. AN ANODE SHALL ALSO BE ATTACHED AT THE END OF EACH LINE. E. MAGNETIC MARKERS MAY BE USED IN LIEU OF COPPER TRACER WIRE TO AID IN FUTURE PIPE MAGNETIC MARKERS MAY BE USED IN LIEU OF COPPER TRACER WIRE TO AID IN FUTURE PIPE LOCATION. GENERALLY, INSTALL MARKERS ON 20 FOOT (6 M) CENTERS. IF PIPE IS IN A CONGESTED PIPING AREA, INSTALL ON 10 FOOT (3 M) CENTERS. PREPARE AS-BUILT DRAWING INDICATING EXACT LOCATION OF MAGNETIC MARKERS.
AutoCAD SHX Text
PROJECT LOCATION
AutoCAD SHX Text
EXISTING SANITARY MAIN
AutoCAD SHX Text
EXISTING SANITARY MANHOLE
AutoCAD SHX Text S
AutoCAD SHX Text 20'
AutoCAD SHX Text 10'
AutoCAD SHX Text
SCALE: 1" = 10'
4'-0" MAX.
1'-0" MAX.1'-0" MAX.
TRENCH WIDTHS
PATCH WIDTH IN
4'-0" MAX.
1'-0" MAX.1'-0" MAX.
VA
R
IE
ST/
T
1'-0" MAX. 1'-0" MAX.1'-0" MAX. 1'-0" MAX.
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
95% SUBMITTAL
FULLY SPRINKLERED
Phase
A/E RENOVATE KITCHEN
BUILDING 100
BAY PINES VAHCS, FLORIDA
516-15-105
12/18/2020 MRI NDP
Matthew R. Ivie, P.E. #86205
Ayres Associates Inc
8875 Hidden River Parkway, Suite 200
Tampa, FL 33637
813-978-8688
CIVIL UTILITIES
TYPICAL DETAILS
CU501
AutoCAD SHX Text FOR TRENCH WIDTHS EXCEEDING 4' [1219mm] REFER TO VA STANDARD DETAIL 32 12 16-02 "TYPE 2 UTILITY TRENCH PATCH". FOR TRENCH WHERE PORTLAND CEMENT CONCRETE (PCC) PAVEMENT EXISTS, REFER TO 32 12 16-03 "TYPE 3 UTILITY TRENCH PATCH".
AutoCAD SHX Text 2" [50mm] MINIMUM OR THICKNESS OF EXISTING PAVEMENT WHICHEVER IS GREATER.
AutoCAD SHX Text BITUMINOUS SURFACE TREATMENT (CHIPSEAL) REQUIRED ONLY FOR LONGITUDINAL TRENCHES WITH WIDTHS GREATER THAN 6' [1829mm].
AutoCAD SHX Text 4" [100mm] MINIMUM ABC OR THICKNESS OF EXISTING GRANULAR BASE COURSE MATERIALS (E.G. ABC & SELECT MATERIAL) WHICHEVER IS GREATER.
AutoCAD SHX Text REFER TO VA STANDARD DETAIL 32 12 16-04 "UTILITY TRENCH PAVEMENT PATCH NOTES" FOR ADDITIONAL INFORMATION.
AutoCAD SHX Text
TYPE 1 UTILITY TRENCH PATCH
AutoCAD SHX Text
AutoCAD SHX Text
NTS
AutoCAD SHX Text [1219mm]
AutoCAD SHX Text [305mm]
AutoCAD SHX Text [305mm]
AutoCAD SHX Text
TRENCH BACKFILL
AutoCAD SHX Text
ABC 100% MIN. COMPACTION
AutoCAD SHX Text
ASPHALTIC CONCRETE
AutoCAD SHX Text
SAW CUT EXISTING. ASPHALT FULL DEPTH BOTH SIDES
AutoCAD SHX Text
TACK COAT (TYP.)
AutoCAD SHX Text
EXISTING PAVEMENT
AutoCAD SHX Text 4" [100mm] MINIMUM ABC OR THICKNESS OF EXISTING GRANULAR BASE COURSE MATERIALS (E.G. ABC & SELECT MATERIAL) WHICHEVER IS GREATER. PORTLAND CEMENT CONCRETE (PCC) THICKNESS EQUAL TO EXISTING.
AutoCAD SHX Text FOR TRENCH WIDTHS 4' [1219mm] OR LESS REFER TO VA STANDARD DETAIL 32 12 16-01 "TYPE 1 UTILITY TRENCH PATCH". FOR TRENCH WHERE PORTLAND CEMENT CONCRETE (PCC) PAVEMENT EXISTS, REFER TO 32 12 16-03 "TYPE 3 UTILITY TRENCH PATCH".
AutoCAD SHX Text 2" [50mm] MINIMUM OR THICKNESS OF EXISTING PAVEMENT WHICHEVER IS GREATER.
AutoCAD SHX Text BITUMINOUS SURFACE TREATMENT (CHIPSEAL) REQUIRED ONLY FOR LONGITUDINAL TRENCHES WITH WIDTHS GREATER THAN 6' [1829mm].
AutoCAD SHX Text REFER TO VA STANDARD DETAIL 32 12 16-04 "UTILITY TRENCH PAVEMENT PATCH NOTES" FOR ADDITIONAL INFORMATION.
AutoCAD SHX Text
TYPE 2 UTILITY TRENCH PATCH
AutoCAD SHX Text
AutoCAD SHX Text
NTS
AutoCAD SHX Text GREATER THAN 4'-0" [1219mm]
AutoCAD SHX Text
TRENCH BACKFILL
AutoCAD SHX Text
SAW CUT EXISTING. ASPHALT FULL DEPTH BOTH SIDES
AutoCAD SHX Text
TACK COAT (TYP.)
AutoCAD SHX Text
EXISTING ASPHALT CONCRETE PAVEMENT
AutoCAD SHX Text
ACCORDANCE WITH AGENCY REQUIREMENTS
AutoCAD SHX Text
GRANULAR MATERIAL OR PCC
AutoCAD SHX Text 2" [50mm] MINIMUM OR THICKNESS OF EXISTING PAVEMENT WHICHEVER IS GREATER.
AutoCAD SHX Text BITUMINOUS SURFACE TREATMENT (CHIPSEAL) REQUIRED ONLY FOR LONGITUDINAL TRENCHES WITH WIDTHS GREATER THAN 6' [1829mm].
AutoCAD SHX Text REFER TO VA STANDARD DETAIL 32 12 16-04 "UTILITY TRENCH PAVEMENT PATCH NOTES" FOR ADDITIONAL INFORMATION.
AutoCAD SHX Text
TYPE 3 UTILITY TRENCH PATCH
AutoCAD SHX Text