Mechanical- Dental.pdf
PDF 7 MB Posted
- Solicitation number
- 36C24724Q0633
About this file
This document is a Combined Synopsis/Solicitation for commercial services for Heating, Ventilation, and Air Conditioning (HVAC), medical air/vacuum systems, and plumbing maintenance and repair services at the Department of Veterans Affairs (VA) Medical Center in Birmingham, Alabama. The solicitation is a 100% Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside with a base period and four option years. The required services include preventative maintenance, repair, and emergency services for the facility's HVAC, steam, and medical air/vacuum systems. The solicitation provides details on the evaluation factors, which include technical capability, past performance, and price. Offerors are required to submit quotes/offers by May 28, 2024, and a site visit is scheduled for May 14, 2024. The contract will use the prevailing wage rates from the attached Davis-Bacon Wage Determination.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 41-M0.1- Gas Boiler.pdf | ||
| Mechanical-Heart Station.pdf | ||
| lattner instruction manual space saver july 2020.pdf | ||
| Mechanical-ORs.pdf | ||
| Mechanical-Ambulatory Clinic.pdf | ||
| Mechanical- Sterile Processing.pdf | ||
| AC6B-Heart Station AHU.pdf | ||
| Futera Fusion 750 Interactive Submittal Data Sheet SFTF 750 7_1.pdf | ||
| 36C24724Q0633_3.docx | DOCX document | |
| 49-M4.1-Gas boiler.pdf | ||
| Mechanical- Pharmacy.pdf | ||
| Updated Attachment A _ Revised May 27 2024.pdf | ||
| 36C24724Q0633_2.docx | DOCX document | |
| STATEMENT OF WORK.pdf | ||
| SCHEDULE.docx | DOCX document | |
| Site Visit Map.pdf | ||
| Wage Determination No 2015-4591 Rev 25.pdf | ||
| 36C24724Q0633_1.docx | DOCX document |
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Building Number
700 SOUTH 19th STREET 35233
VAMC-BIRMINGHAM, ALABAMALocation:Approved: Service Director
DEPARTMENT OF VETERANS AFFAIRS
MEDICAL CENTER
BIRMINGHAM,ALABAMA
Date
PROJECTS MANAGEMENT
ENGINEERING SERVICE (138)
SCALE:
DRAWING NAME PROJECT NAME: DATE:
DRAWING NUMBER:
FILE:
DRAWN BY:CHECKED BY:
PROJECT NUMBER:
524 West Peachtree St NW
Atlanta GA 30308 t 404 876 3800
Rosser International, Inc.
www.rosser.com
12345678
8 7 6 5 4 3 2 1
G
F
E
D
C
B
A
Revisions
DENTAL RENOVATION &
INCREASE MEDICINE BEDS
521-326
VA 248-C-0838
ROSSER 09076.00
H
G
F
E
D
C
B
A
H
01/06/2012
This drawing and all prints of it are the property of Rosser International, Inc. Prints are to be returned to Rosser International, Inc. upon completion of use for which they were issued.
Reproductions of these drawings without written consent of Rosser International, Inc. is not permitted and Rosser International, Inc. retains all common law, statutory and other reserved rights, including the copyright thereto.
This Record Document has been prepared, in part, based upon construction information furnished by others. While this information is believed to be reliable, Rosser International cannot assure its accuracy, and thus is not responsible for the accuracy of this Record
Document or for any errors or omissions which may have been incorporated into it as a result.AS-BUILT RECORD DRAWING 01/06/2012
A S -B
U
IL
T R
E C
O R
D D
R A
W
IN
G
A S -B
U
IL
T R
E C
O R
D D
R A
W
IN
G
AS-BUILT RECORD DRAWING
AS-BUILT RECORD DRAWING
LEGEND, ABBREVIATIONS
& GENERAL NOTES
NONE W. CURRY M0.01
M0701.DGN
GENERAL NOTES:
G1. COORDINATE ALL WORK WITH OTHER TRADES PRIOR TO INSTALLATION.
G3. DUCT SIZES SHOWN ARE ACTUAL INSIDE DIMENSIONS.
G4. OPEN ENDS OF TRANSFER AIR DUCTS AND RETURN AIR DUCTS 18" AND LARGER IN
EITHER DIMENSION SHALL BE REINFORCED WITH 1�"x 1�"x 20 GAUGE ANGLES
ON ALL SIDES. SECURE ANGLES TO DUCT WITH SHEET METAL SCREWS MAXIMUM 12
INCHES ON CENTER
G6. RETURN AIR PLENUMS AT AIR HANDLING EQUIPMENT SHALL BE FULL SIZE OF UNIT
INLET.
G7. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF GRILLES
AND DIFFUSERS IN CEILINGS.
G8. RUNOUTS TO AIR DISTRIBUTION DEVICES SHALL BE NOMINAL NECK SIZE OF AIR
DISTRIBUTION DEVICE UNLESS NOTED OTHERWISE. ROUND RUNOUTS OVER GYPBOARD
OR PLASTER CEILINGS SHALL BE RIGID.
G9. ALL SUPPLY RUNOUTS, BRANCH DUCTS, OR TAKE-OFFS TO AIR DISTRIBUTION DEVICES
SHALL BE PROVIDED WITH MANUAL DAMPERS. ROUND DUCTS SHALL BE CONNECTED TO
RECTANGULAR DUCTS WITH ROUND BRANCH TAKE-OFFS. RECTANGULAR RUNOUTS AND
BRANCH TAKE-OFFS SHALL BE CONNECTED TO RECTANGULAR DUCT WITH 45 ENTRY
FITTING AND VOLUME DAMPER.
o
12" LONG FLANGED &
GASKETED DUCT SECTION
6 X 8 ACCESS DOOR
12 X 12 ACCESS DOOR
18 X 12 ACCESS DOOR
10" & SMALLER
12" TO 15"
16" TO 24"
25" & LARGER
24 X 24
G10. UNLESS NOTED OTHERWISE, ACCESS SHALL BE PROVIDED ADJACENT TO ALL MOTOR
OPERATED DAMPERS, FIRE DAMPERS, SMOKE DAMPERS, AND COMBINATION FIRE/SMOKE
DAMPERS AS FOLLOWS:
DUCT SIZE (INCHES) DUCT ACCESS (INCHES) CEILING ACCESS PANEL (INCHES)
G11. THE FOLLOWING IS USED TO IDENTIFY THE AIR DISTRIBUTION DEVICES:
10" n CD
300 CFM
TYP OF 2
NECK SIZE TYPE OF DEVICE (CD, ER, ETC.)
AIRFLOW NUMBER TYPICAL
G12. PROVIDE TRANSITION TO VAV BOX INLET WHERE INLET SIZE DIFFERS FROM RUNOUT
SIZE. TRANSITION SHALL OCCUR AT INLET.
G13. ALL HOT WATER PIPING RUNOUTS TO TERMINAL UNITS SHALL BE �" UNLESS OTHERWISE
NOTED.
PLANS. SEE ELECTRICAL PLANS FOR VOLTAGE AND PHASE REQUIREMENTS BEFORE
SUBMITTING AND ORDERING MECHANCIAL EQUIPMENT.
G5. ELECTRICAL CHARACTERISTICS OF EQUIPMENT ARE NOT SHOWN ON THE MECHANICAL
G2. UNLESS OTHERWISE INDICATED, INSTALL ALL SPACE THERMOSTATS 48 INCHES
ABOVE FINISHED FLOOR.
A/C
ACU
AD
AHU
BTUH
CD
CFM
CLG
CO
CONC
CONN
CONT
CU
DG
DN
DOM
DS
DWGS
EA
EDH
EF
EG
ELEC
ER
EXH
EXIST
FCU
FPB
GPM
HWC
HVAC
LD
MAX
MIN
OA
OC
RA
RG
RR
RTU
SG SUPPLY AIR GRILLE
SMD SMOKE DAMPER
SR SUPPLY AIR REGISTER
TG TRANSFER GRILLE
TYP TYPICAL
UH UNIT HEATER
VAV VARIABLE AIR VOLUME UNIT
WITH
WALL HEATER
WALL OPENING
AFF
EL
SKD
SPS
WH
WO
W/
SMOKE DETECTOR
STATIC PRESSURE SENSOR
DOOR GRILLE
DOWN
DOMESTIC
DUCT SILENCER
DRAWINGS
EACH
ELECTRIC DUCT HEATER
EXHAUST FAN
EXHAUST AIR GRILLE
ELECTRIC
EXHAUST AIR REGISTER
EXHAUST
EXISTING
FAN COIL UNIT
FAN POWERED BOX
GALLONS PER MINUTE
HOT WATER COIL
HEATING VENTILATING & AIR CONDITIONING
LINEAR DIFFUSER
MAXIMUM
MINIMUM
OUTSIDE AIR
ON CENTER
RETURN AIR
RETURN AIR GRILLE
RETURN AIR REGISTER
ROOFTOP UNIT
ELEVATION
CONDENSING UNIT
ABOVE CEILING
AIR CONDITIONING UNIT
DUCT ACCESS DOOR
AIR HANDLING UNIT
BRITISH THERMAL UNITS PER HOUR
CEILING DIFFUSER
CUBIC FEET PER MINUTE
CEILING
CLEAN OUT
CONCRETE
CONNECT
CONTINUATION
ABOVE FINISHED FLOOR
CONDENSATE DRAIN CD
HOT WATER SUPPLY HWS
HOT WATER RETURN HWR
REFRIGERANT LIQUID RL
REFRIGERANT SUCTION RS
REFRIGERANT GAS RG
CHILLED WATER SUPPLY CHS
CHILLED WATER RETURN CHR
RG
RS
RL
HWR
HWS
CHR
CHS
CD
ABBREVIATION DESCRIPTIONSYMBOL ABBREVIATION DESCRIPTION
LEGEND & ABBREVIATIONS
PIPING
DUCTWORK
PIPE UP
PIPE DOWN
PIPE BRIDGE
EXISTING DUCT & EQUIP ON DEMOLITION PLANS
FLEXIBLE DUCT
DUCT TRANSITION
AIR EXTRACTER
DUCT DOWN
DUCT UP
TURNING VANES
DIRECTION OF FLOW
DAMPERS
SD
BRANCH SPLITTER
MLD/MD MANUAL DAMPER
MOD MOTOR OPERATED DAMPER
SMD SMOKE DAMPER
SPLITTER DAMPER
CONTROLS
T’STAT THERMOSTAT T
CONNECT TO EXISTING
MISCELLANEOUS
ROUND
FO FLAT OVAL
n
FD FIRE DAMPER
M
S
VALVES / FITTINGS / SPECIALTIES
FSD
HPU
FSD
UNO UNLESS NOTED OTHERWISE
HEAT PUMP UNIT
FIRE/SMOKE DAMPER
EXISTING DUCT & EQUIP ON NEW PLANS
SINGLE LINE DUCT
G14. AUTOMATIC AIR VENTS ON TOP OF AIR SEPARATORS SHALL BE PIPED FULL SIZE TO
FLOOR DRAIN.
INSIDE OUTSIDE
HEAT.HEAT. COOLING COOLING
DB F DB F DB F DB FWB F WB F
BUILDING AREA
DESIGN CONDITIONS
HOSPITAL OCCUPIED AREAS 70 75 63 21 94 75
PULL CLO.
T.
1 2
F.H.C.
STAIR 3
Building Number
700 SOUTH 19th STREET 35233
VAMC-BIRMINGHAM, ALABAMALocation:Approved: Service Director
DEPARTMENT OF VETERANS AFFAIRS
MEDICAL CENTER
BIRMINGHAM,ALABAMA
Date
PROJECTS MANAGEMENT
ENGINEERING SERVICE (138)
SCALE:
DRAWING NAME PROJECT NAME: DATE:
DRAWING NUMBER:
FILE:
DRAWN BY:CHECKED BY:
PROJECT NUMBER:
524 West Peachtree St NW
Atlanta GA 30308 t 404 876 3800
Rosser International, Inc.
www.rosser.com
12345678
8 7 6 5 4 3 2 1
G
F
E
D
C
B
A
Revisions
DENTAL RENOVATION &
INCREASE MEDICINE BEDS
521-326
VA 248-C-0838
ROSSER 09076.00
H
G
F
E
D
C
B
A
H
01/06/2012
This drawing and all prints of it are the property of Rosser International, Inc. Prints are to be returned to Rosser International, Inc. upon completion of use for which they were issued.
Reproductions of these drawings without written consent of Rosser International, Inc. is not permitted and Rosser International, Inc. retains all common law, statutory and other reserved rights, including the copyright thereto.
This Record Document has been prepared, in part, based upon construction information furnished by others. While this information is believed to be reliable, Rosser International cannot assure its accuracy, and thus is not responsible for the accuracy of this Record
Document or for any errors or omissions which may have been incorporated into it as a result.AS-BUILT RECORD DRAWING 01/06/2012
A S -B
U
IL
T R
E C
O R
D D
R A
W
IN
G
A S -B
U
IL
T R
E C
O R
D D
R A
W
IN
G
AS-BUILT RECORD DRAWING
AS-BUILT RECORD DRAWING
N
1 1 1 1 1 1
1 3
1 3
1 3
6th FLOOR DEMOLITION PLAN M2.02
SCALE: �"=1’-0"
1.
2.
3.
4.
5.
6.
7.
VERIFY ALL DIMENSIONS PRIOR TO BEGINNING WORK. NOTIFY ARCHITECT
IMMEDIATELY OF ANY DISCREPANCIES.
WHERE EXISTING MATERIALS ARE INDICATED TO BE REMOVED, SURFACES AND
EDGES SHALL BE SUITABLE FOR THE INSTALLATION OF NEW WORK. REMOVE
PAINT, DUST, MASTIC, MORTAR, FASTENERS, ETC. WHICH WILL BE DETRIMENTAL
TO THE INSTALLATION OF NEW MATERIALS.
PREVENT DAMAGE TO EXISTING MATERIALS TO REMAIN. PREVENT DAMAGE TO
EXISTING MATERIALS TO BE REMOVED AND RELOCATED OR REINSTALLED.
REMOVE ALL ABANDONED PIPING AND PIPING ACCESSORIES. PROVIDE PERMANENT
AND TEMPORARY SEALS OVER OPEN ENDS OF ALL PIPING TO REMAIN.
ITEMS TO BE REMOVED
COORDINATE DEMOLITION WORK WITH NEW LAYOUT. COORDINATE WORK WITH
DEMOLITION AND NEW WORK SHOWN ON MECHANICAL, ELECTRICAL AND
PLUMBING DRAWINGS.
6 NO WORK THIS AREA
EXISTING CHILLED WATER PIPING ABOVE CEILING TO REMAIN.
EXISTING OUTSIDE AIR DUCTWORK MAIN TRUNK ABOVE CEILING TO REMAIN. REMOVE
ALL BRANCH DUCTS; CAP AND SEAL DUCT
EXISTING STEAM AND CONDENSATE RETURN PIPING ABOVE CEILING TO REMAIN
REMOVE EXISTING FAN COIL UNIT, SUPPLY AND RETURN DUCTWORK AND
AIR DEVICES. CLOSE SERVICE VALVES ON CHILLED WATER, STEAM AND CONDENSATE
RETURN PIPING. REMOVE PIPING AND DEVICES ON COIL SIDE OF VALVES. VALVES
SHALL BE REUSED IN FUTURE AND NEW PIPING ATTACHED. REMOVE
THERMOSTAT AND ASSOCIATED CONTROL WIRING.
2 2 2
3 3
3 3
4 4
7 7
N KEY PLAN
EXISTING EXHAUST DUCT TO BE REMOVED. CAP AND SEAL AT EDGE OF CONSTRUCTION
BOUNDRY.
EXSTING TO REMAIN
CONTRACTOR TO PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, DELIVERY, OVERHEAD
AND OTHER ITEMS NECCESSARY TO ACCOMPLISH THE WORK.
HAUL OFF AND LAWFULLY DISPOSE OF ALL DEMOLISHED MATERIAL TO OFF SITE LOCATION
LIMITS OF WORK
REMOVE HORIZONTAL DUCTWORK LABELED AS "HAZARDOUS" CAP AND SEAL
AT SHAFT PENETRATION
THE OWNER IS TO BE GIVEN A MINIMUM OF 72 HOURS ADVANCE NOTICE ON ALL
UTILITY OUTAGES. A 5 DAY MINIMUM ADVANCE NOTICE IS REQUIRED ON ALL
MAJOR UTILITY OUTAGES.
NO UTILITIES OR SYSTEMS ARE TO BE TAKEN OFF LINE, TERMINATED OR ALTERED
WITHOUT THE OWNER’S PRIOR KNOWLEDGE & APPROVAL.
8.
9.
6th FLOOR
MECHANICAL
DEMOLITION PLAN
�"=1’-0" JTA W. CURRY M2.02
M0202.DGN
GENERAL DEMOLITION NOTES
DEMOLITION KEYNOTES
LEGEND
F.H.C.
ELECTROMECH
LOLOTOSHO
LOLOTOSHO1507D
OFFICE
1507C
OFFICE
1507E
OFFICE
1507F
OFFICE
1507G
OFFICE
1507H
OFFICE
OFFICE
1507A
OFFICE
1507B
OFFICE
15291530
OFFICE
ELECTROMECH
LOLOTOSHO
EXAM
EXAM
EXAM
EXAM
OFFICE
CONFERENCE STAIR #5
NUCLEAR MEDICINE SERVICE
TREATMENT
E X
IT
E X
IT
E X
IT
EXIT
Building Number
700 SOUTH 19th STREET 35233
VAMC-BIRMINGHAM, ALABAMALocation:Approved: Service Director
DEPARTMENT OF VETERANS AFFAIRS
MEDICAL CENTER
BIRMINGHAM,ALABAMA
Date
PROJECTS MANAGEMENT
ENGINEERING SERVICE (138)
SCALE:
DRAWING NAME PROJECT NAME: DATE:
DRAWING NUMBER:
FILE:
DRAWN BY:CHECKED BY:
PROJECT NUMBER:
524 West Peachtree St NW
Atlanta GA 30308 t 404 876 3800
Rosser International, Inc.
www.rosser.com
12345678
8 7 6 5 4 3 2 1
G
F
E
D
C
B
A
Revisions
DENTAL RENOVATION &
INCREASE MEDICINE BEDS
521-326
VA 248-C-0838
ROSSER 09076.00
H
G
F
E
D
C
B
A
H
01/06/2012
This drawing and all prints of it are the property of Rosser International, Inc. Prints are to be returned to Rosser International, Inc. upon completion of use for which they were issued.
Reproductions of these drawings without written consent of Rosser International, Inc. is not permitted and Rosser International, Inc. retains all common law, statutory and other reserved rights, including the copyright thereto.
This Record Document has been prepared, in part, based upon construction information furnished by others. While this information is believed to be reliable, Rosser International cannot assure its accuracy, and thus is not responsible for the accuracy of this Record
Document or for any errors or omissions which may have been incorporated into it as a result.AS-BUILT RECORD DRAWING 01/06/2012
A S -B
U
IL
T R
E C
O R
D D
R A
W
IN
G
A S -B
U
IL
T R
E C
O R
D D
R A
W
IN
G
AS-BUILT RECORD DRAWING
AS-BUILT RECORD DRAWING
REMOVEABLE
HATCHES OVER
TRANSFORMER
N
ITEMS TO BE REMOVED
ITEMS TO REMAIN
1 1
1 1
1st FLOOR DEMOLITION PLAN M2.03
SCALE: �"=1’-0"
2nd FLOOR DEMOLITION PLAN M2.03
SCALE: �"=1’-0"
N
1 1
1 1
1 1
1 1 1
1 1
1 1
1 1
1 1
1 1
1 1
N
6 NO WORK THIS AREA
6 6
LIMITS OF CONSTRUCTION
LIMITS OF CONSTRUCTION
LIMITS OF CONSTRUCTION
LIMITS OF CONSTRUCTION 1
1 1
1.
2.
3.
4.
5.
6.
7.
VERIFY ALL DIMENSIONS PRIOR TO BEGINNING WORK. NOTIFY ARCHITECT
IMMEDIATELY OF ANY DISCREPANCIES.
WHERE EXISTING MATERIALS ARE INDICATED TO BE REMOVED, SURFACES AND
EDGES SHALL BE SUITABLE FOR THE INSTALLATION OF NEW WORK. REMOVE
PAINT, DUST, MASTIC, MORTAR, FASTENERS, ETC. WHICH WILL BE DETRIMENTAL
TO THE INSTALLATION OF NEW MATERIALS.
PREVENT DAMAGE TO EXISTING MATERIALS TO REMAIN. PREVENT DAMAGE TO
EXISTING MATERIALS TO BE REMOVED AND RELOCATED OR REINSTALLED.
REMOVE ALL ABANDONED PIPING AND PIPING ACCESSORIES. PROVIDE PERMANENT
AND TEMPORARY SEALS OVER OPEN ENDS OF ALL PIPING TO REMAIN.
COORDINATE DEMOLITION WORK WITH NEW LAYOUT. COORDINATE WORK WITH
DEMOLITION AND NEW WORK SHOWN ON MECHANICAL, ELECTRICAL AND
PLUMBING DRAWINGS.
CONTRACTOR TO PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, DELIVERY, OVERHEAD
AND OTHER ITEMS NECCESSARY TO ACCOMPLISH THE WORK.
HAUL OFF AND LAWFULLY DISPOSE OF ALL DEMOLISHED MATERIAL TO OFF SITE LOCATION
THE OWNER IS TO BE GIVEN A MINIMUM OF 72 HOURS ADVANCE NOTICE ON ALL
UTILITY OUTAGES. A 5 DAY MINIMUM ADVANCE NOTICE IS REQUIRED ON ALL
MAJOR UTILITY OUTAGES.
NO UTILITIES OR SYSTEMS ARE TO BE TAKEN OFF LINE, TERMINATED OR ALTERED
WITHOUT THE OWNER’S PRIOR KNOWLEDGE & APPROVAL.
8.
9.
DENTAL CLINIC - 1st & 2nd FLOOR
HVAC
DEMOLITION PLANS
�"=1’-0" J.AKERS W.CURRY M2.03
M0203.DGN
REMOVE EXISTING DUCTWORK, PIPING, AND VAV BOXES
EXISTING DUCT PENETRATIONS THROUGH WALL TO REMAIN,
FIRE DAMPER ( IF PRESENT) SHALL ALSO REMAIN
FUME HOOD EXHAUST DUCT AND CONTROLS TO REMAIN
REMOVE GRILLE FROM WALL, PATCH AND SEAL
1 1
1 1
WORK IN THIS AREA UNDER SEPARATE CONTRACT
REMOVE EXISTING, AHU, DUCTWORK AND FANS.
PIPING THROUGH ROOM SHALL REMAIN
1 1 1 1 1 1
DEMOLITION KEYNOTES
KEY PLAN
LEGEND
GENERAL DEMOLITION NOTES
A B C D E F
LOLOTOSHO
LOLOTOSHO
1507E
VOLUNTEER
ELECTROMECH
OFFICE
OFFICE
REMOVEABLE
HATCHES OVER
TRANSFORMER
E X
IT
EXIT
EXIT
EXIT
Building Number
700 SOUTH 19th STREET 35233
VAMC-BIRMINGHAM, ALABAMALocation:Approved: Service Director
DEPARTMENT OF VETERANS AFFAIRS
MEDICAL CENTER
BIRMINGHAM,ALABAMA
Date
PROJECTS MANAGEMENT
ENGINEERING SERVICE (138)
SCALE:
DRAWING NAME PROJECT NAME: DATE:
DRAWING NUMBER:
FILE:
DRAWN BY:CHECKED BY:
PROJECT NUMBER:
524 West Peachtree St NW
Atlanta GA 30308 t 404 876 3800
Rosser International, Inc.
www.rosser.com
12345678
8 7 6 5 4 3 2 1
G
F
E
D
C
B
A
Revisions
DENTAL RENOVATION &
INCREASE MEDICINE BEDS
521-326
VA 248-C-0838
ROSSER 09076.00
H
G
F
E
D
C
B
A
H
01/06/2012
This drawing and all prints of it are the property of Rosser International, Inc. Prints are to be returned to Rosser International, Inc. upon completion of use for which they were issued.
Reproductions of these drawings without written consent of Rosser International, Inc. is not permitted and Rosser International, Inc. retains all common law, statutory and other reserved rights, including the copyright thereto.
This Record Document has been prepared, in part, based upon construction information furnished by others. While this information is believed to be reliable, Rosser International cannot assure its accuracy, and thus is not responsible for the accuracy of this Record
Document or for any errors or omissions which may have been incorporated into it as a result.AS-BUILT RECORD DRAWING 01/06/2012
A S -B
U
IL
T R
E C
O R
D D
R A
W
IN
G
A S -B
U
IL
T R
E C
O R
D D
R A
W
IN
G
AS-BUILT RECORD DRAWING
AS-BUILT RECORD DRAWING
128127
111 112
129 130
124123
106 107 108
H W
R
HWS
HWR
H W
S
H W
R
HWR
HWS
H W
S
H W
R
HWS
H W
S
N
N
DENTAL CLINIC
1st FLOOR - HVAC
RENOVATION PLAN
�"=1’-0" J.AKERS W.CURRY M3.01
M0301.DGN
1st FLOOR RENOVATION PLAN-HVAC M3.01
SCALE: �"=1’-0"
LIMITS OF WORK
LIMITS OF WORK
n 8" CD
210 CFM
n 8" CD
210 CFM
n 8" CD
210 CFM
n 8" CD
210 CFM
n 8" CD
210 CFM
n 8" CD
210 CFM
n 8" CD
210 CFM
n 8" CD
210 CFM
10X8 SR
25 CFM
n10" CD
300 CFM
n10" CD
300 CFM
n10" CD
300 CFM
n10" CD
300 CFM
n 8" CD
200 CFM
n 6" CD
135 CFM
n 6" CD
25 CFM
n10" CD
240 CFM
n10" CD
240 CFM
n10" CD
240 CFM
n10" CD
250 CFM
n 8" CD
140 CFM
n 8" CD
140 CFM
n 8" CD
150 CFM
n 8" CD
150 CFM
n 6" CD
110 CFM
n 8" CD
165 CFM
n 8" CD
165 CFM
n 8" CD
165 CFM
n 8" CD
165 CFM
n 8" CD
165 CFM
n 6" CD
50 CFM
n 6" CD
100 CFM
n 8" CD
155 CFM
n 8" CD
155 CFM
n 8" CD
155 CFM
n 8" CD
165 CFM
n 8" CD
150 CFM
n 6" CD
80 CFM
12X12 20X14 36X14
X
8X8 EG
100 CFM
8X8 EG
100 CFM
20X20 EG
780 CFM
20X20 EG
780 CFM
X
20X1224X14
8X8 EG
130 CFM
8X6
X
8X6
10X10 EG
130 CFM
10X10 EG
130 CFM
RG
RG
RG
RG
RG
n 8" CD
205 CFM
12X12 EG
190 CFM
12X12 EG
200 CFM
10X6
10X6
10X6
10X6
10X6
NOTES:
1 ROUTE DUCT FULL SIZE OF DIFFUSER NECK CONNECTION TO DUCT
WITH BALANCING DAMPER
X
14X10 16X10
18X10
X
X
14X10
22X12
X
12X6
X
24X12
30X12
34X16
15 CFM
120 CFM
34X22
80 CFM
80 CFM
85 CFM
85 CFM
105 CFM
95 CFM
90 CFM
105 CFM
105 CFM
105 CFM
14X12
X
X
X
X
10X8 10X8
14X12
X
10X10
X
X
X
8X12
X
14X1210X12
X
10X12
10X8
24X1214X1010X10
10X6
10X6 n 4" n 4"
1"
1"
1"
1�"
2"
1�"1�"
2"
1�"
1"
2"
2"
12X10 WALL OPENING
ABOVE CEILING
OPEN TO RETURN
PLENUM, BALANCE
TO 565 CFM
16X12
2 12X6 DOWN IN CHASE. INSTALL EXHAUST GRILLE WITHIN 6" AFF
10X10 WEG
190 CFM
10X10 WEG
190 CFM
12X6
12X8
CHILLED WATER COOLING COIL
STEAM PRE-HEAT
X
20X10 DOWN IN CHASE
8X30 WEG
960 CFM
WITHIN 6" AFF
CONNECT TO EXISTING
LOUVER FOR OUTDOOR AIR
INTAKE
10X8 SR
25 CFM
EXTEND 6X6 EXHAUST DUCT INTO ROOM AND DOWN
THROUGH RATED CEILING WITH FIRE DAMPER AND
ACCESS DOOR. INSTALL BALANCING DAMPER IN DROP,
SET TO 50 CFM. EXTEND DUCT DOWN TO WITHIN 12"
ABOVE FINISHED FLOOR WITH 1/4"X1/4" HARDWARE CLOTH
12X10 WALL
OPENING
ABOVE CEILING34X12
12X6 20X10
10X10 WEG
165 CFM
12X6
X
10X10 WEG
160 CFM
10X6
50 CFM
12X6
CONDENSATE DOWN
61X14
FILTER MIXING BOX WITH
TOP RELIEF AND BACK RETURN
SUPPLY FAN
ECONOMIZER SECTION WITH TOP
OUTSIDE AIR AND AIRLFLOW STATION
CONNECT TO EXISTING
LOUVER FOR OUTDOOR AIR INTAKE
CONNECT TO
EXISTING DUCT
FOR RELIEF AIR DISCHARGE
SUPPLY PLENUM WITH VERTICAL DISCHARGE
90%-95% FINAL FILTER WITH
MERV 8 PREFILTER
X
STEAM PIPE
CHILLED
WATER
PIPES
VFD
X
28X20
50X20
36X24
15 CFM
X
CONDENSATE
RETURN FROM
ABOVE.
105 CFM
n 8"
12X10 WALL
OPENING
ABOVE CEILING
8X8 EG
100 CFM
10X8 SR
25 CFM10X10 EG
130 CFM
10X10 EG
125 CFM
10X10 EG
125 CFM
10X10 EG
125 CFM
10X10 EG
130 CFM
8X8 EG
100 CFM
10X10 EG
130 CFM
10X10 EG
130 CFM
HAC
STORAGE
BREAK
X-RAY
RECEPTION
RADIOGRAPH
STORAGE
TOILETTOILET
ELEV. #1
ELEV. #2
WAITING
TOILET
TOILET
STAIR
CORRIDOR
CORRIDOR
C O
R R
ID
O R
C O
R R
ID
O R
OPERATIVE
OPERATIVE
HYGIENE
HYGIENE
FUTURE ORAL
SURGERY
ORAL
SURGERY
ORAL
SURGERY
ORAL
SURGERY
ORAL
SURGERYORAL
DIAGNOSIS
ORAL
DIAGNOSIS
PERIODONTAL
PERIODONTAL
PERIODONTAL
ENDODONTICS
ENDODONTICS
NOS
ELECT.
KEY PLAN
VAV-1/06VAV-1/07
VAV-1/08
VAV-1/10
VAV-1/05
VAV-1/03
VAV-1/04
VAV-1/11
AHU-1
VAV-1/02
VAV-1/01
VAV-1/09
1 2
F.H.C.
STAIR 3
AC BA
C
BA
C
BA
C
C
C
BA
C
BA
C
A
Building Number
700 SOUTH 19th STREET 35233
VAMC-BIRMINGHAM, ALABAMALocation:Approved: Service Director
DEPARTMENT OF VETERANS AFFAIRS
MEDICAL CENTER
BIRMINGHAM,ALABAMA
Date
PROJECTS MANAGEMENT
ENGINEERING SERVICE (138)
SCALE:
DRAWING NAME PROJECT NAME: DATE:
DRAWING NUMBER:
FILE:
DRAWN BY:CHECKED BY:
PROJECT NUMBER:
524 West Peachtree St NW
Atlanta GA 30308 t 404 876 3800
Rosser International, Inc.
www.rosser.com
12345678
8 7 6 5 4 3 2 1
G
F
E
D
C
B
A
Revisions
DENTAL RENOVATION &
INCREASE MEDICINE BEDS
521-326
VA 248-C-0838
ROSSER 09076.00
H
G
F
E
D
C
B
A
H
01/06/2012
This drawing and all prints of it are the property of Rosser International, Inc. Prints are to be returned to Rosser International, Inc. upon completion of use for which they were issued.
Reproductions of these drawings without written consent of Rosser International, Inc. is not permitted and Rosser International, Inc. retains all common law, statutory and other reserved rights, including the copyright thereto.
This Record Document has been prepared, in part, based upon construction information furnished by others. While this information is believed to be reliable, Rosser International cannot assure its accuracy, and thus is not responsible for the accuracy of this Record
Document or for any errors or omissions which may have been incorporated into it as a result.AS-BUILT RECORD DRAWING 01/06/2012
A S -B
U
IL
T R
E C
O R
D D
R A
W
IN
G
A S -B
U
IL
T R
E C
O R
D D
R A
W
IN
G
AS-BUILT RECORD DRAWING
AS-BUILT RECORD DRAWING
M
M
N
N
PATIENT UNIT
6th FLOOR
RENOVATION PLAN
�"=1’-0" W. CURRY M3.03
M0303.DGN
NOTES:
6th FLOOR RENOVATION PLAN - HVAC DUCTWORK M3.03
SCALE: �"=1’-0"
n12" CD
400 CFM
n12" CD
400 CFM
n10" CD
300 CFM
n 6" CD
75 CFM
n 6" CD
50 CFM
10X6 SG
50 CFM
n 6" n10" n10" n 6" n 8"
TYP
16X10 n10"n10" CD
315 CFM
n 8" CD
190 CFM
TYP OF 3
n 8" n 6" CD
75 CFM
n 6" n 8" CD
165 CFM
TYP OF 2
n 8" CD
165 CFM
TYP OF 3
n 8" n 6"
10X6 SG
50 CFM
1 1
X n 8"
10X10 n 6" CD
60 CFM
n 6" CD
130 CFM
TYP OF 2
X n 6"
14X12 n10" CD
300 CFM
n 6" n12" CD
400 CFM
n 6" n10" n 6"
8X8 ER
75 CFM
X
X
14X14 ER
220 CFM
8X6
8X8 ER
75 CFM
VAV-6BS1
VAV-6BS2
n 6" CD
75 CFM
n12" CD
400 CFM
n12" CD
400 CFM
n 6" CD
75 CFM
n 6"
10X6 SG
50 CFM
1 1
X
10X6 SG
50 CFM
n12" CD
400 CFM
n10" n 6" n10"
10X6 SG
50 CFM
n 6" n12" CD
400 CFM
n10" n 6"
10X6 SG
50 CFM
14X10 n12" CD
400 CFM
n10" n 6"
10X6 SG
50 CFM
n12" CD
400 CFM
n10"
10X6 SG
50 CFM
n 6"
14X10 n 6"
10X6 SG
50 CFM
n12" CD
200 CFM
n10" n10" n12" CD
200 CFM
n12" CD
200 CFM
n12" CD
200 CFM
n10" n 6"10X6 SG
50 CFM
n10" 14X10 n12" CD
400 CFM
n10" n 6" n12" CD
400 CFM
n10"
INSTALL 24" DEEP RETURN PLENUM AND 12" DEEP SUPPLY PLENUM ON UNIT.
SIZE SHALL MATCH UNIT CONNECTION.
FILTER RETURN GRILLES (FRG) SHALL HAVE FILTER SIZE TO
MATCH HOSPITAL STANDARD. SIZE SHOWN IS NECK SIZE.
PRESSURE INDEPENDENT AIRFLOW CONTROL VALVE, CONTROLLED BY ISOLATION
ROOM PRESSURE CONTROLLER.
ISOLATION ROOM PRESSURE CONTROLLER, OPERATION AND
FUNCTIONS SHALL MATCH FIFTH FLOOR.
INSTALL 24X36 FIRE RATED ACCESS DOOR IN SHAFT.
605 604
625627
632631
621 623
ISOLATION
ISOLATION
X
X
6X4
6X4
6X4
6X4
6X4
6X46X4
6X4
6X4
X
X
X
8X8 EG
75 CFM
X
8X4
8X4
X
8X612X6 16X816X10
EXTEND 22X10 EA DUCT BACK TO
EXISTING EXHAUST FAN; REBALANCE
EA TO 1100 CFM AT THIS BRANCH DUCT.
EXTEND 18X10 OA DUCT BACK TO
EXISTING AIR HANDLER; REBALANCE
OA TO 1100 CFM ON THIS BRANCH DUCT.
X
X
18X10
10X8
22X10
X
8X6
8X8 EG
100 CFM
8X8 EG
75 CFM
8X8 EG
75 CFM
8X8 EG
75 CFM
8X8 EG
75 CFM
8X8 EG
75 CFM
X
8X8 EG
75 CFM
TYP OF 2
X
8X4
8X8 EG
75 CFM
X
E G
C F
M
14X10
22X12
14X8
12X8
22X22 FRG
925 CFM
6X4
14X14 FRG
425 CFM
14X14 FRG
420 CFM
14X10
14X14 FRG
300 CFM
14X8
14X14 FRG
300 CFM
14X14 FRG
425 CFM
8X8 EG
75 CFM
14X10
14X14 FRG
425 CFM
14X10
14X14 FRG
425 CFM
14X14 FRG
325 CFM
14X8 14X10
14X14 FRG
420 CFM
16X16 FRG
555 CFM
14X14 FRG
360 CFM
14X14 FRG
190 CFM
14X10
14X14 FRG
6X4
14X14 FRG
425 CFM
14X10
14X14 FRG
425 CFM
10X6 SG
50 CFM
14X14 FRG
425 CFM
14X10
KEY PLAN
FCU-B
FCU-D
FCU-C
FCU-C
FCU-C
FCU-C
FCU-C
FCU-C
FCU-E
FCU-C
FCU-C
FCU-C
TOILET
HAC
STORAGE TOILET
TOILET TOILET TOILET
TOILETTOILET
TOILET
TOILET
TOILET
TOILET
TOILET
1 BED
1 BED
1 BED
1 BED
1 BED
1 BED
1 BED
CLOSET ELECTROMECH
NURSE STATION
MEDICINE
KITCHEN
TOILET
1 BED
1 BED
ANTE-
ROOM
ANTE-
ROOM
CORRIDOR
C O
R R
ID
O R
1 BED
1 BED
STAIR 3
STAIR 1
1 BED
1 BED
TOILET
SOILED UTL
CLEAN
STORAGE
NURSE
MDN
CONFERENCE
BREAK ROOM
LINEN &
EQUIPMENT
STORAGE
STORAGE
FCU-E
FCU-C
FCU-C
FCU-A
1 2
F.H.C.
STAIR 3
AC BA
C
BA
C
BA
C
C
C
BA
C
BA
C
A
Building Number
700 SOUTH 19th STREET 35233
VAMC-BIRMINGHAM, ALABAMALocation:Approved: Service Director
DEPARTMENT OF VETERANS AFFAIRS
MEDICAL CENTER
BIRMINGHAM,ALABAMA
Date
PROJECTS MANAGEMENT
ENGINEERING SERVICE (138)
SCALE:
DRAWING NAME PROJECT NAME: DATE:
DRAWING NUMBER:
FILE:
DRAWN BY:CHECKED BY:
PROJECT NUMBER:
524 West Peachtree St NW
Atlanta GA 30308 t 404 876 3800
Rosser International, Inc.
www.rosser.com
12345678
8 7 6 5 4 3 2 1
G
F
E
D
C
B
A
Revisions
DENTAL RENOVATION &
INCREASE MEDICINE BEDS
521-326
VA 248-C-0838
ROSSER 09076.00
H
G
F
E
D
C
B
A
H
01/06/2012
This drawing and all prints of it are the property of Rosser International, Inc. Prints are to be returned to Rosser International, Inc. upon completion of use for which they were issued.
Reproductions of these drawings without written consent of Rosser International, Inc. is not permitted and Rosser International, Inc. retains all common law, statutory and other reserved rights, including the copyright thereto.
This Record Document has been prepared, in part, based upon construction information furnished by others. While this information is believed to be reliable, Rosser International cannot assure its accuracy, and thus is not responsible for the accuracy of this Record
Document or for any errors or omissions which may have been incorporated into it as a result.AS-BUILT RECORD DRAWING 01/06/2012
A S -B
U
IL
T R
E C
O R
D D
R A
W
IN
G
A S -B
U
IL
T R
E C
O R
D D
R A
W
IN
G
AS-BUILT RECORD DRAWING
AS-BUILT RECORD DRAWING
M
M
N
N
EXISTING CHILLED WATER SUPPLY
EXISTING CHILLED WATER RETURN
EXISTING CHILLED WATER RETURN
EXISTING CHILLED WATER RETURN
EXISTING CHILLED WATER SUPPLY
EXISTING CHILLED WATER SUPPLY
EXISTING CONDENSATE DRAIN LINE
EXISTING CONDENSATE DRAIN LINE
EXISTING CONDENSATE DRAIN LINE
NOTES:
EXISTING STEAM AND CONDENSATE RETURN RISER1
1 1 1 1
6th FLOOR RENOVATION PLAN - HVAC PIPING M4.03
SCALE: �"=1’-0"
2 3
1" LP STEAM
�" CONDENSATE RETURN
621 623
ISOLATION
ISOLATION
PROVIDE AND INSTALL CONDENSATE PUMP. ROUTE�"
CONDENSATE LINE FROM DISCHARGE OF PUMP TO
MAIN CONDENSATION PIPE AS SHOWN.
NEW �" STEAM SUPPLY AND �" CONDENSATE RETURN TO NEW FAN COIL UNIT OR VAV BOX.
SLOPE CONDENSATE RETURN BACK TO RISER AT �" PER FOOT.
1 "
1 "
1 "
1" LP STEAM
�" CONDENSATE RETURN
PATIENT UNIT
6th FLOOR RENOVATION PLAN
HVAC PIPING
�"=1’-0" W. CURRY M4.03
M0403.DGN
KEY PLAN
FCU-B
FCU-D
FCU-C
FCU-C
FCU-C
FCU-C
FCU-C
FCU-C
FCU-C
FCU-A
FCU-C
FCU-E
FCU-C
FCU-C
FCU-C
TOILET
HAC
STORAGE
TOILET
TOILET
TOILET TOILET
TOILET
TOILET
TOILET
TOILET
TOILET
TOILET
TOILET
1 BED
1 BED
1 BED
1 BED
1 BED
1 BED
1 BED
CLOSET
ELECTROMECH
NURSE STATION
MEDICINE
KITCHEN
TOILET
1 BED
1 BED
ANTE-
ROOM
ANTE-
ROOM
CORRIDOR
C O
R R
ID
O R
1 BED
1 BED
STAIR 3
STAIR 1
1 BED
1 BED
TOILET
SOILED UTL
CLEAN
STORAGE
NURSE
MDN
BREAK ROOM
LINEN &
EQUIPMENT
STORAGE
STORAGE
CONFERENCE
FCU-E
700 SOUTH 19th STREET 35233
VAMC-BIRMINGHAM, ALABAMALocation:Approved: Service Director
DEPARTMENT OF VETERANS AFFAIRS
MEDICAL CENTER
BIRMINGHAM,ALABAMA
Date
PROJECTS MANAGEMENT
ENGINEERING SERVICE (138)
SCALE:
DRAWING NAME PROJECT NAME: DATE:
DRAWING NUMBER:
FILE:
DRAWN BY:CHECKED BY:
PROJECT NUMBER:
524 West Peachtree St NW
Atlanta GA 30308 t 404 876 3800
Rosser International, Inc.
www.rosser.com
12345678
8 7 6 5 4 3 2 1
G
F
E
D
C
B
A
Revisions
DENTAL RENOVATION &
INCREASE MEDICINE BEDS
521-326
VA 248-C-0838
ROSSER 09076.00
H
G
F
E
D
C
B
A
H
01/06/2012
This drawing and all prints of it are the property of Rosser International, Inc. Prints are to be returned to Rosser International, Inc. upon completion of use for which they were issued.
Reproductions of these drawings without written consent of Rosser International, Inc. is not permitted and Rosser International, Inc. retains all common law, statutory and other reserved rights, including the copyright thereto.
This Record Document has been prepared, in part, based upon construction information furnished by others. While this information is believed to be reliable, Rosser International cannot assure its accuracy, and thus is not responsible for the accuracy of this Record
Document or for any errors or omissions which may have been incorporated into it as a result.AS-BUILT RECORD DRAWING 01/06/2012
A S -B
U
IL
T R
E C
O R
D D
R A
W
IN
G
A S -B
U
IL
T R
E C
O R
D D
R A
W
IN
G
AS-BUILT RECORD DRAWING
AS-BUILT RECORD DRAWING
DETAILS
NONE W. CURRY M6.01
M0601.DGN
NTS
VARIABLE AIR VOLUME AIR HANDLING UNIT WITH MINIMUM OUTSIDE AIR CONTROL DIAGRAM
P R
IL
T E
R
OUTSIDE
AIR
D-1
C O
P R
E H
E A
T
C
O L
IN
G
LOCATE SENSOR
OUTSIDE UNDER
SHIELD
MPS
V-2
V-1
CHR
CHS
SUPPLY FAN
F
IN
A L
T E
R
A F
M D
SUPPLY AIR TO
TERMINAL UNIT
TT
TT
TT TT
HT
FT
D-4
A F
M D
MINIMUM
OUTSIDE
AIR
HS
CS
VFD
T-5
T-2
T-3 T-6
IT
SD
PRESSURE SWITCH HIGH
TO DISABLE FAN WHEN HIGH PRESSURE
LIMIT SETPOINT IS REACHED
PSH
SMOKE
DETECTOR
VARIABLE FREQUENCY
DRIVE, TYP.
DIFFUSER
SECTION
ZC
ZC
FT DPS
TT
T-1
SST
SPD
HHL
DPS
SD
SPS
TSL
TSL-1
UNIT IS NORMALLY STARTED AND STOPPED REMOTELY AT THE ECC. H-O-A SWITCH SHALL
BE KEPT IN THE "AUTO" POSITION. "HAND" AND "OFF" POSITIONS SHALL BE USED ONLY
FOR MAINTENANCE. WHEN THE UNIT IS "OFF" D-1, D-3, SHALL BE FULLY CLOSED. WHEN
THE UNIT IS "ON" D-1, SD-1 AND SD-2 SHALL BE FULLY OPEN. D-2 AND D-3 SHALL
MODULATE IN ACCORDANCE WITH THE FOLLOWING SEQUENCE:
6.
6.1
6.2
THE SUPPLY AIR FLOW SHALL BE CONTROLLED BY THE DIGITAL CONTROL PANEL
MODULATING THE SUPPLY FAN ADJUSTABLE SPEED MOTOR CONTROLLER TO MAINTAIN 1.0"
[25mm] OF DUCT STATIC PRESSURE (FIELD ADJUSTABLE), SENSED BY SPS-1. RESET
STATIC PRESSURE BASED ON ACTUAL BUILDING LOAD BY POLLING ALL ATU
THE DIGITAL CONTROL PANEL, USING TOTAL SUPPLY AIR AND RETURN AIR FLOW SIGNALS,
SHALL RESET THE RETURN AIR FAN ASD TO MAINTAIN A CONSTANT AIR FLOW DIFFERENCE
BETWEEN THE SUPPLY AIR AND THE RETURN AIR EQUAL TO MINIMUM OUTSIDE AIR.
USING HIGH PRESSURE SENSOR SPS-2 LOCATED AT THE SUPPLY FAN DISCHARGE, SHALL
PREVENT THE SUPPLY FAN FROM DEVELOPING OVER 3" [75mm] OF STATIC PRESSURE
(FIELD ADJUSTABLE). IF STATIC PRESSURE AT SPS-2 DOES EXCEED 3" [75mm] THE
SUPPLY AIR FAN SHALL STOP. SPS-2 SHALL BE HARDWIRED TO THE SUPPLY FAN UFD
AND UNIT SHALL BE SHUTDOWN IN HAND,AUTO OR BYPASS MODE. SPS-2 WILL REQUIRE
MANUAL RESET AT THE DEVICE.
UPON FAILURE OF THE VFD, THE SUPPLY AND RETURN FANS SHALL BE STARTED/STOPPED
MANUALLY AT THE DIGITAL CONTROL PANEL OR THE ECC THROUGH THE BY-PASS
STARTER. FANS SHALL THEN BE OPERATED AT CONSTANT SPEED.
IF THE AIR TEMPERATURE AS SENSED BY TT-3 FALLS BELOW 45°F [7°C], AN ALARM
SIGNAL SHALL INDICATE AT THE DCP AND ECC. IF THIS TEMPERATURE FALLS BELOW 40°F
[4.4°C], AS SENSED BY THE TSL THE SUPPLY AND RETURN FANS SHALL SHUT DOWN AND
A CRITICAL ALARM SHALL INDICATE AT THE DIGITAL CONTROL PANEL AND ECC. TSL SHALL
BE HARDWIRED TO THE SUPPLY FAN UFD AND UNIT SHALL BE SHUTDOWN IN HAND,AUTO
OR BYPASS MODE. TSL WILL REQUIRE MANUAL RESET AT THE DEVICE.
WHEN SMOKE IS DETECTED BY DUCT SMOKE DETECTOR, SD, THE SUPPLY AND RETURN
FANS SHALL SHUT "OFF" AND AN ALARM SIGNAL SHALL BE TRANSMITTED TO THE FIRE
ALARM SYSTEM. ALL SMOKE DAMPERS IN THE SUPPLY AND RETURN DUCTS SHALL CLOSE.
EXHAUST FANS SERVING AREA OF THE SUPPLY FAN SHALL CONTINUE TO RUN. SUPPLY
AND RETURN FANS SHALL RESTART AND SMOKE DAMPERS SHALL OPEN WHEN FIRE ALARM
CIRCUIT IS RESET.
ALARM
PROCESSING
D U
T Y
C
L E
F U
N C
T
IO
N
S C
H E
D U
L E
S
T A R
T
S T O
P
SUPPLY FAN VFD ALARM
STATIC PRESSURE HIGH LIMIT
Supply Air Flow (cfm)
RETURN LOW PRESSURE
S T A T U
S
SYSTEM
A L
A R
M
P R
IO
R
IT
Y
A D
D
A L T E R
N A
N
E L E
C T
IC
D
V
IC
E
S P
E
M M
A N
D
P O
IN
T
ID
Discharge Static Pressure
Discharge Air Humidity
Discharge Air Temperature
Pre-Heat Temperature
Mixed Air Temperature
Cooiling Coil Temperature
SYSTEM COMPONENT:
Return Air Flow (cfm)
Return air Temperature
O P
E N
C L
O S
E
S T A R
T
S T O
P
V A L
V E
P
O S
IT
IO
N
D A
M P
E R
P
O S
IT
IO
N
VAV AIR HANDLER
SYSTEM:
BUILDING:
LEGEND
POINT
BINARY
T E
M P
E R
A T U
R E
T I)
L o c a l
A la rm
P a n e l
M a s te r
A la rm
P a n e l
A re a la rm
P a n e l
H
IG
H
S
T A T
IC
P
R E S S
U R
E
H
IG
H
U
M
ID
IT
Y
P R
E S S
U R
E
L
W
M P
E R
A T U
R E
P E
R C
E N
T
P R
E S S
U R
E
P O
S
IT
IO
N F L
O W
H
IG
IM
IT
L
IT
SYSTEM INPUTS
ANA- BINARY ANALOG
S P
A
M P
C O
N T R
O L
S T A T
IC
P
R E S S
U
S
E T
D E
M A
IT
IN
G
T E
M P
E R
A T U
S
E T
T E
M P
E R
A T U
V E
R R
ID
E
E N
T H
A L P
O N
O M
IZ
E R
T E
M P
E R
A T U
O N
O M
IZ
E R
F A
IL
U
D E
P R E S S
U R E
V O
L U
N T R
O L
REMARKS
F U
M M
U N
IC
A T
IO
N
SYSTEM SOFTWARE/CONTROL
APPLICATION/FUNCTION
Return Air Humidity
SUPPLY FAN STATUS
MIXED AIR LOW LIMIT
RETURN AIR DAMPER
COILING VALVE V-1
PRE-HEAT VALVE V-2
SUPPLY FAN VFD
OUTSIDE AIR DAMPER
S T A T
IC
P
R E S S
U R
E
C A R
B
N O
X
ID
E
H U
M
ID
IT
Y V
A C
U U
M
STEAM ISOLATION VALVE V-3
SUPPLY FAN START/STOP
AI-1
AI-2
AI-3
AI-4
AI-5
AI-6
AI-7
AI-8
AI-9
AI-10
T R
E N
D
IN
G
OUTSIDE AIR TEMPERATURE AI-11
BI-1
BI-3
BI-4
BI-5
BI-7
AO-2
AO-3
AO-4
AO-8
AO-9
BO-2
BO-3
FULL COMMUNICATION
A B
B R
E V
IA
T
IO
N
RAT
RAH
RAF
MAT
PHT
CCT
DAT
DASP
DAH
SAF
OAT
RLP
SF-STS
TSL-1
SPS-2
SF-ALA
SF-SPD
OAD
RAD
PHT-V1
CLG-V1
SF-SST
HUM-ISO-V3
NTS
MINIMUM OUTSIDE AIR
POINTS LIST FOR VAV AIR HANDLING UNIT WITH
OUTPUTS
LOG
NTS
ROOM THERMOSTAT/SENSOR
WALL MOUNTED
48" [1200mm] AFF.
VARIABLE VOLUME AIR TERMINAL UNIT CONTROL DIAGRAM
RHC
HWS
HWR
V-1
REHEAT
COIL
AIR
TERMINAL
UNIT
AIR
FLOW
TE
ATU
CONTROLLER
PC
TE
IR
F M
HEATING
MINIMUM
SP
W/DEADBAND
100%
V
V
F L O
WR
E
H E
A T
F L O
W
A. SET POINTS SHALL BE SET AS FOLLOWS:
COOLING SET POINTS WILL BE MAINTAINED.
B. UPON FALL IN SPACE TEMPERATURE THE
VAV DAMPER WILL MODULATE TO MINIMUM
POSITION.
C. UPON FURTHER DROP IN SPACE
TEMPERATURE VALVE V-1 WILL MODULATE
TO MAINTAIN SET POINT
ADJUSTABLE TOLERANCE OF
BEEN SELECTED TO PREVENT VALVE
HUNTING
D. THE REVERSE SHALL OCCUR ON THE RISE
IN SPACE TEMPERATURE.
FE
M6.01
M6.01
M6.01
1.
1.1
SUPPLY AIR TEMPERATURE, SENSED BY TT-1, SHALL BE MAINTAINED AT SETPOINT VIA
DIGITAL CONTROL PANEL BY MODULATING V-1 OR D-2 AND D-3 OR V-2 IN SEQUENCE.
WHEN THE TEMPERATURE OF THE OUTSIDE AIR, SENSED BY TT-2, IS ABOVE 75°F (ADJ)
[23.8°C], THE DIGITAL CONTROL PANEL SHALL PREVENT THE MODULATION OF D-2 AND
D-3 AND SHALL ASSUME THE MINIMUM OUTSIDE AIR POSITION (D-2 FULLY OPENED AND
D-3 FULLY CLOSED). THE DIGITAL CONTROL PANEL SHALL MODULATE V-1 TO MAINTAIN
THE SUPPLY AIR TEMPERATURE, SENSED BY TT-1.
WHEN THE TEMPERATURE OF THE OUTSIDE AIR, SENSED BY TT-2, IS BETWEEN 65°F
[18.3°C] AND THE SUPPLY AIR TEMPERATURE SENSED BY TT-1, DAMPER D-2 SHALL
FULLY CLOSE AND D1 AND D3 SHALL BE FULLY OPEN (MAXIMUM OUTSIDE AIR POSITION).
THE DIGITAL CONTROL PANEL SHALL MODULATE V-1 TO MAINTAIN THE SUPPLY AIR
TEMPERATURE, SENSED BY TT-1.
WHEN THE TEMPERATURE OF THE OUTSIDE AIR, SENSED BY TT-2, IS BELOW THE SUPPLY
AIR TEMPERATURE, SENSED BY TT-1, DAMPERS D1, D-2 AND D-3 SHALL MODULATE TO
MAINTAIN THE SCHEDULED SUPPLY AIR TEMPERATURE. IF D-2 IS OPEN AND D-3 IS
CLOSED TO MINIMUM OUTSIDE AIR, V-2 SHALL MODULATE OPEN TO MAINTAIN THE SUPPLY
AIR TEMPERATURE, SENSED BY TT-1.
2.
2.1
2.2
2.3
2.4
3.
3.1
3.2
3.3
5.
5.1
7.
7.1
VAV
BIRMINGHAM MEDIAL CENTER-DENTAL AREAS
SEQUENCE OF OPERATION FOR VARIABLE AIR VOLUME AIR HANDLING UNIT WITH MINIMUM
OUTSIDE AIR
AUTOMATIC SHUTDOWN/RESTART
VAV BOX CONTROL SEQUENCE
GENERAL
TEMPERATURE CONTROL
AIR FLOW CONTROL
FREEZE PROTECTION
EMERGENCY CONSTANT SPEED OPERATION
700 SOUTH 19th STREET 35233
VAMC-BIRMINGHAM, ALABAMALocation:Approved: Service Director
DEPARTMENT OF VETERANS AFFAIRS
MEDICAL CENTER
BIRMINGHAM,ALABAMA
Date
PROJECTS MANAGEMENT
ENGINEERING SERVICE (138)
SCALE:
DRAWING NAME PROJECT NAME: DATE:
DRAWING NUMBER:
FILE:
DRAWN BY:CHECKED BY:
PROJECT NUMBER:
524 West Peachtree St NW
Atlanta GA 30308 t 404 876 3800
Rosser International, Inc.
www.rosser.com
12345678
8 7 6 5 4 3 2 1
G
F
E
D
C
B
A
Revisions
DENTAL RENOVATION &
INCREASE MEDICINE BEDS
521-326
VA 248-C-0838
ROSSER 09076.00
H
G
F
E
D
C
B
A
H
01/06/2012
This drawing and all prints of it are the property of Rosser International, Inc. Prints are to be returned to Rosser International, Inc. upon completion of use for which they were issued.
Reproductions of these drawings without written consent of Rosser International, Inc. is not permitted and Rosser International, Inc. retains all common law, statutory and other reserved rights, including the copyright thereto.
This Record Document has been prepared, in part, based upon construction information furnished by others. While this information is believed to be reliable, Rosser International cannot assure its accuracy, and thus is not responsible for the accuracy of this Record
Document or for any errors or omissions which may have been incorporated into it as a result.AS-BUILT RECORD DRAWING 01/06/2012
A S -B
U
IL
T R
E C
O R
D D
R A
W
IN
G
A S -B
U
IL
T R
E C
O R
D D
R A
W
IN
G
AS-BUILT RECORD DRAWING
AS-BUILT RECORD DRAWING
DETAILS
NONE W. CURRY M6.02
M0602.DGN
ASSEMBLY
NTS
FLOAT AND THERMOSTATIC STEAM TRAP
1. ALL DRIP POINTS ON STEAM MAINS SHALL BE PROVIDED WITH A 12" MINIMUM HIGH DRIP LEG
FROM BOTTOM OF STEAM MAIN TO TRAP INLET. DRIP LEG SHALL HAVE 6" SCALE POCKET
BELOW TRAP INLET.
TO RETURN MAIN
PIPE SIZE SHALL BE SAME SIZE
AS TRAP
FLOAT AND THERMOSTATIC
TRAP. SEE PLANS, AND
SCHEDULES
DIELECTRIC FITTING
WHERE RETURN IS
COPPER PIPE
FL
OW
SCHEDULE 80
STEEL PIPE
BYPASS-INSTALL IN HORIZONTAL
PLANE LEVEL WITH TRAP OR IN
VERTICAL PLANE & BELOW TRAP
PROVIDE BYPASS PIPING FOR ALL
TRAPS 1" AND LARGER.
IN
IN
DRIP LEG OR EQUIPMENT
CONNECTION. MAKE THE SAME
SIZE AS THE SUPPLY MAIN OR
EQUIPMENT CONNECTION. SEE
NOTE 1
m m m m
SCHEDULE 80 STEEL PIPE
SEE DRAWINGS FOR PIPE SIZES
1" GATE
VALVE
M6.02
5 FT
THRU [20]
6 8 10
[32][25] [40]
[65]
[50]
[75]
-1312 14 -16 -
[125][100]
[150]
[250]
[200]
[300]
[400]
[350]
[450]
[600]
[500]
20 241814 16128 1064 532 2 1/21 1/21 1 1/4
[9100][9600][8500][7600] [8200][7000][5800] [6700][5200][4100] [4900][3700][3000] [3400][2700][2100]
--- --[4900] -[4100][3700] [4000] -[3000][2400][1800][1500]
THRU 3/4
[2100] [2100]
[2100]
[2700]
[2400]
NTS
PROVIDE INSULATION SHIELD
& INSERT FOR ALL PIPING
(8" [200mm] MIN.)
BAND
1-5/8" [43mm] 12 GAUGE
CHANNEL OR 2"x2"x1/4"
[50x50x6.4mm] ANGLE
1/2" [15mm] DIA.
HANGER RODS WITH
36" [900mm] MAX.
SPACING ON EACH
CHANNEL
WELD
SADDLE
INSULATION SHIELD
AT HANGER
PROVIDE HIGH COMPRESSIVE
STRENGTH INSULATION (9
PSF MIN. DENSITY) UNDER
INSULATION SHIELD
INSULATION (VAPOR
BARRIER TYPE IS
REQUIRED FOR LOW
TEMPERATURE PIPE)
HANGER ROD
MAXIMUM PIPE/TUBING SUPPORT SPACING
NOTE: FOR TRAPEZE HANGER TAKE SPACING OF SMALLEST SIZE ON TRAPEZE.
NOM. SIZE
PIPE
TUBING
IN.
[mm]
FT.
[mm]
FT.
[mm]
PIPE HANGERS
m m
X
NOTES:
SEE SPECIFER FOR DETAILED
HANGER REQUIREMENTS
M6.02 NTS
ABOVE 2" [50mm] DIA. PIPE 2" [50mm] DIA. & SMALLER
ABOVE 2" [50mm] DIA. PIPE 2" [50mm] DIA. & SMALLER
INSTALLATION OF THERMOMETER WELLS
2 1/2" [65mm] DIA.
M6.02
AIR HANDLING UNIT DRAIN TRAP DETAIL
NTS
DRAW THRU
BLOW THRU
2" [50mm]
PLUS X
1" [25mm]
MINIMUM
X
2X
UNIT TYPE A B
WHERE X = STATIC PRESSURE IN PAN
DRAIN LINE SHALL BE AT LEAST THE SAME
SIZE AS THE NIPPLE ON THE DRAIN PAN
PIPING SHALL BE RIGID COPPER TYPE L OR
TYPE M UNLESS NOTE BELOW IS MET
PITCH DOWN
TOWARD DRAIN
CLEAN OUT
FLOOR SINK
DRAIN
PAN
1. CPVC PIPE MAY BE USED ONLY IF APPROVED BY
LOCAL VA AND IS INDOORS AND DOES NOT PASS THROUGH RATED
BARRIERS.
2. DIELECTRIC FITTING TO BE USED WHEN TWO DISSIMILAR METALS
ARE TO BE CONNECTED.
1355.2mA
1345.77mB m m
DIELECTRIC
FITTING
314.06m1"
M6.02
PIPING CONNECTIONS
NTS
COIL
TEST PLUG (TYP.)
REDUCER, IF REQUIRED
WATER RETURN
MANUAL AIR VENT
UNION CONNECTIONS
(TYP.)
WATER SUPPLY
TERMINAL UNIT WATER COILS -
SHUT OFF VALVE
DRAIN WITH HOSE
CONNECTION
MV
MODULATION CONTROL VALVE
M6.02
NOTE:
SIDE VIEW TRAPEZE HANGER FOR UP TO
1000 LB. [453KG] UNIFORM LOAD
ADJUSTABLE CLEVIS HANGER
TYPE 1 - SEE SPECIFICATIONS
ADJUSTABLE CLEVIS HANGER
TYPE 43 - SEE SPECIFICATIONS
VERTICAL
HORIZONTAL
NOTE:
700 SOUTH 19th STREET 35233
VAMC-BIRMINGHAM, ALABAMALocation:Approved: Service Director
DEPARTMENT OF VETERANS AFFAIRS
MEDICAL CENTER
BIRMINGHAM,ALABAMA
Date
PROJECTS MANAGEMENT
ENGINEERING SERVICE (138)
SCALE:
DRAWING NAME PROJECT NAME: DATE:
DRAWING NUMBER:
FILE:
DRAWN BY:CHECKED BY:
PROJECT NUMBER:
524 West Peachtree St NW
Atlanta GA 30308 t 404 876 3800
Rosser International, Inc.
www.rosser.com
12345678
8 7 6 5 4 3 2 1
G
F
E
D
C
B
A
Revisions
DENTAL RENOVATION &
INCREASE MEDICINE BEDS
521-326
VA 248-C-0838
ROSSER 09076.00
H
G
F
E
D
C
B
A
H
01/06/2012
This drawing and all prints of it are the property of Rosser International, Inc. Prints are to be returned to Rosser International, Inc. upon completion of use for which they were issued.
Reproductions of these drawings without written consent of Rosser International, Inc. is not permitted and Rosser International, Inc. retains all common law, statutory and other reserved rights, including the copyright thereto.
This Record Document has been prepared, in part, based upon construction information furnished by others. While this information is believed to be reliable, Rosser International cannot assure its accuracy, and thus is not responsible for the accuracy of this Record
Document or for any errors or omissions which may have been incorporated into it as a result.AS-BUILT RECORD DRAWING 01/06/2012
A S -B
U
IL
T R
E C
O R
D D
R A
W
IN
G
A S -B
U
IL
T R
E C
O R
D D
R A
W
IN
G
AS-BUILT RECORD DRAWING
AS-BUILT RECORD DRAWING
DETAILS
NONE W. CURRY M6.03
M0603.DGN
NTS
DUCTWORK SQUARE VANE ELBOWS
1.
2.
3.
4.
ALL VANE ELBOWS SHALL BE CONSTRUCTED AND INSTALLED AS DETAILED BY
SMACNA.
WHEN W1 DOES NOT EQUAL W2, VANE SHALL BE SINGLE THICKNESS VANE TYPE
REGARDLESS OF W DIMENSION.
ALL SINGLE THICKNESS VANES SHALL HAVE A 2" [50mm] RADIUS, 1 1/2"
[40mm] MAXIMUM SPACE BETWEEN VANES AND A 3/4" [20mm] TRAILING EDGE.
WHEN W EQUALS W2 AND W1 IS GREATER THAN 20" [500mm] VANES SHALL BE
DOUBLE VANE TYPE.
1707.51mW2
1765.32mW1
M6.03
NTS
DUCTWORK RADIUS ELBOWS
VANE
VANE
1.
2.
THE INTERIOR SURFACE OF ALL RADIUS ELBOWS SHALL BE MADE ROUND.
ALL STANDARD RADIUS ELBOWS CAN BE SUBSTITUTED WITH SHORT RADIUS
ELBOWS. ALL SHORT RADIUS ELBOWS SHALL HAVE VANES. VANES SHALL BE
CONSTRUCTED, SUPPORTED AND FASTENED AS RECOMMENDED BY SMACNA.
R SHALL
EQUAL OR
BE
GREATER
THAN W.
R SHALL
EQUAL OR
BE
GREATER
THAN
1/3W.
1006.87mW
957.31mR R
973.02m2/3W
487.07m1/3W
R SHALL
EQUAL OR
BE
GREATER
THAN
1/6W.
1499.49m W 1684.43m W
996.86m1/2W
502.24m1/3W
235.36m 1/6W
R
M6.03
NTS
SUPPLY DUCTWORK TAKE-OFFS
AIR
FLOW
AIR
FLOW
O W
965.61m
SUPPLY REGISTER
OR BRANCH DUCT
TURNING VANES
MAIN
SUPPLY
DUCT
SEE FLOOR PLAN FOR
SPLIT DIMENSION
PROVIDE VOLUME
DAMPER
PROVIDE VOLUME
DAMPER
ADJUSTABLE
METAL ROD
OR LINKAGE
TOP REGISTER
MAIN
SUPPLY
DUCT
VOLUME EXTRACTOR; ADJUSTABLE
FROM FULLY CLOSED POSITION TO
CFM NOTED ON FLOOR PLANS
AIR
FLOW
AIR
FLOW
455.98m
1/4 W OR 4"
[100mm] MIN.
AIR
FLOW
MAIN SUPPLY
DUCT
914.38m W
O W
M6.03
NTS
EXHAUST OR RETURN BRANCH DUCTWORK
MAIN EXHAUST OR RETURNAIR
FLOW AIR
FLOW
498.8m
1052.15mW
PROVIDE VOLUME DAMPER
AT EACH BRANCH DUCT
1/4W OR 4"
[100mm] MIN.
BRANCH DUCT
VD
M6.03
NTS
VOLUME DAMPER DETAIL
1.
2.
DELETE INSULATION STAND-OFF ON DUCTWORK WITHOUT EXTERIOR INSULATION.
DETAIL SHOWS SINGLE BLADE DAMPER. DAMPER INSTALLATION SHALL BE SIMILAR
FOR MULTI-BLADE DAMPERS & ROUND DAMPERS.
INSULATION SEE
SPECIFICATION
DAMPER BLADE
1/8" [6mm]
CLEARANCE
ALL AROUND
OUTSIDE END BEARING
INSIDE END BEARING
HANDLE WITH
LOCKING
QUADRANT
INSULATION
STAND-OFF
1/2" [15mm] ROUND
ROD PIN
DUCT
STIFFEN BLADE
AS REQUIRED
M6.03
"B" "B"
ACCESS PANEL AND DOOR DETAIL
NTS
1. LATCHES SHALL BE OF THE WEDGE TYPE TO CLOSE DOORS
TIGHTLY.
2. HINGES ON THE ACCESS DOORS SHALL HAVE NON-CORROSIVE
PINS.
3. SEE SMACNA 2005, FIGURE 9-15
CASING
GASKET
HANDLE INSIDE
FLEXIBLE
WASHER
FACTORY
FABRICATED
LATCH
INSULATION
DUCT
GASKET
INSULATION
INSULATION
"A"
"A"
M6.03
NTS
ACCESS SECTION FOR ROUND/OVAL DUCT
HOUSING WELDED
TO DUCT SECTION
ROUND OR
FLAT OVAL
DUCT SECTION
COVER WITH HANDLE
AND CHAIN RETAINER
GASKETED AND
PRESSURE SEALED
M6.03
NTS
FLEXIBLE DUCT CONNECTIONS
FLANGED CONNECTION
ON FAN SIDE
WASHER 1-1/2" [40mm] MIN. TO 3" [75mm]
MAX. INSTALLED. 6" [150mm]
NOMINAL WITH MATERIAL TAUT
FLEXIBLE
MATERIAL AS
SPECIFIED
1"x1/8" [25x3mm] DRAW BAND
1"x1/8" [25x3mm] BAND IRON
BOLT ON 4" [100mm] CENTERS
5/16" [8mm] FLANGE
DUCT
SHEET METAL SCREWS ON
12" [300mm] CENTERS
RIVET ON 4"
[100mm]
CENTERS
SHEET METAL AS
SPECIFIED FOR
DUCTWORK.
1"x1/8" [25x3mm] BAND IRON
BOLT ON 4" [100mm] CENTERS
1" [25mm] FLANGE & HEMALTERNATE
POSITION
OF BOLT 1 1/2" [40mm]
POCKET SLIP
DUCT
SHEET METAL AS
SPECIFIED FOR
DUCTWORK.
536.45m 1/2"
[15mm] 536.45m 1/2"
[15mm] 1609.34m 1609.34m1 1/2"
[40mm]
1 1/2" [40mm] MIN. TO 3" [75mm]
MAX. INSTALLED. 6" [150mm]
NOMINAL WITH MATERIAL TAUT
4506.16m
FLANGED
CONNECTION
ON FAN SIDE
WASHER
FLEXIBLE MATERIAL
AS SPECIFIED
M6.03
NTS
FIRE DAMPER INSTALLATION
SECTION THRU
SLEEVE, NOTE 2
DUCT
CONNECTION
NOTE 4
DAMPER,
NOTE 1
DAMPER COLLAR
EXTENSION INTEGRAL
PART OF SLEEVE
SLEEVE, NOTE 2
NOTE 6FIRE BARRIER
PARTITION OR CHASE
TYPICAL DUCT
INSULATION
PERIMETER ANGLE, NOTE 3
(NOTE FASTENED TO PARTITION)
ACCESS
PANEL
NOTE 5
423.52m 1" m m
A VERTICAL DAMPER IS SHOWN. HORIZONTAL DAMPER INSTALLATION, 1S SIMILAR.
FOLLOW DAMPER MANUFACTURER’S INSTRUCTIONS, INCLUDING FASTENER OPTIONS AND
GAGES FOR SLEEVE AND PERIMETER ANGLES. FIRE DAMPERS MUST BE INSTALLED IN
THE PARTITION OR FLOOR AND NOT OUTSIDE THE PENETRATION.
GALVANIZED SLEEVE: GAGE NOT LESS THAN CONNECTING DUCT. FASTEN SLEEVE TO
DAMPER FRAME AND TO PERIMETER ANGLES.
PERIMETER ANGELS: GALVANIZED STEEL, NOT LESS THAN 1 1/2"x1 1/2" [40x40mm], 14 GAGE, TO PROVIDE 1" [25mm] MINIMUM OVERLAP OF OPENING ON ALL 4 SIDES.
BREAKAWAY DUCT CONNECTION: CONTRACTOR’S OPTION OF TYPES SHOWN IN SMACNA.
ACCESS PANELS: SIZE AND LOCATION TO PERMIT SERVICING THE FUSIBLE LINK OR
LINKS.
PROVIDE 1/4" TO 1/2" [6 TO 15mm] CLEARANCE ON HEIGHT AND WIDTH. FILL OPEN
SPACE WITH ROCK WOOL FIRESTOP FIBER.
ALL DUCT WORK RISERS WHICH ARE RUN EXPOSED, SUCH AS THRU ATTIC FLOORS
AND MECHANICAL ROOM FLOORS, SHALL BE PROVIDED WITH 3" [75mm] HIGH
CONCRETE CURB AROUND OPENING FOR DUCT.
1.
2.
3.
4.
5.
6.
M6.03
NTS
ROUND DUCT HANGERS
2500 [1133]
1320 [598]
420 [190]ONE 1 [25] x 18 GA STRAP36 [900]
ONE 1 [25] x 16 GA STRAP
84 [2100]
60 [1500]
50 [1250] 700 [317]
ONE 1 [25] x 22 GA STRAP
QUANTITY/SIZE
26 [650]
HANGER STRAPS OR RODS
MAX. LOAD
LBS. [kg]
260 [119]
MAX.
144 [3600]
IN. [mm]
SPACING
IN. [mm] IN. [mm]
144 [3600]
144 [3600]
144 [3600]
144 [3600]
TABULATED DATA FROM SMACNA
ALLOWS FOR DUCT REINFORCING AND
INSULATION, BUT NO EXTERNAL LOAD.
BAND
OVER 50"
HANGER RODS
BAND OF SAME
SIZE AS HANGER
STRAP
LOAD RATED
FASTENERS
50"
UNDER
DESCRIBE OR DETAIL UPPER ATTACHMENTS APPLICABLE TO PARTICULAR
PROJECTS.
M6.03
NTS
DUCT CONNECTIONS - AIR TERMINAL UNITS
1.
2.
3.
4.
5.
6.
RIGID STRAIGHT TERMINAL UNIT INLET LENGTH SHALL BE A
MINIMUM OF 3 TIMES THE DIAMETER OF INLET
A FLEXIBLE AIR DUCT CONNECTOR IS NOT MANDATORY FOR INLET TO
THIS BOX, BUT ALLOWED TO ACCOMMODATE MINOR OFFSETS. MAXIMUM
LENGTH 3’-0" [900mm].
A BRANCH DUCT SERVING AN INDIVIDUAL BOX MAY BE THE SAME SIZE
AS THE BOX INLET, PROVIDED THE EQUIVALENT LENGTH OF THE
BRANCH DUCT, AS SHOWN, DOES NOT EXCEED 10 FEET (3 METERS).
FOR LONGER LENGTHS, INCREASE THE DUCT SIZE AND PROVIDE A
DUCT TRANSITION TO MAINTAIN THE DUCT STATIC PRESSURE DROP AT
OR BELOW 0.2"/100’ [1.64Pa/m].
FLEXIBLE AIR DUCT CONNECTORS, WHEN USED FROM TERMINAL UNIT
SUPPLY AIR DUCT TO DIFFUSER, SHALL NOT EXCEED 5’-0" [1500mm].
COMPONENT ARRANGEMENT MAY VARY BY MANUFACTURER. PROVIDE
INSULATION W/VAPOR BARRIER FOR CONNECTING DUCT SECTIONS.
USE OF THE FLEXIBLE AIR DUCT CONNECTORS ARE NOT PERMITTED
FOR THE DEDICATED AHU SERVING THE SURGICAL SUITE.
AIR TERMINAL UNIT
(CV OR VAV)
REHEAT COIL
FLEXIBLE AIR DUCT
CONNECTOR. SEE DETAIL
DIFFUSER (TYP.)
SEE SPECIFICATIONS FOR
CLAMPS AND SEALANT (TYP.)
SEE NOTE 5
2628.6mSEE NOTE 4
4571.09mSEE NOTE 3
914.95mSEE NOTE 2
1460.29mSEE NOTE 1
SEE NOTE 1
SEE NOTE 2
SEE NOTE 3
S
M6.03
NOTE:
NOTE:
STANDARD RADIUS OR
LONG RADIUS ELBOW
SHORT RADIUS ELBOW
WITH ONE VANE
SHORT RADIUS ELBOW
WITH TWO VANES
AIR SPLIT DUCT TAKE-OFF
PLAN VIEW
BRANCH DUCT TAKE-OFF PLAN VIEW
SUPPLY REGISTER TAKE-OFF
PLAN VIEW
PLAN VIEW
NOTE:
SIDE ELEVATION SECTION
SECTION "A-A"
NOTES:
ACCESS PANEL
ACCESS DOOR SECTION "B-B"
ROUND FLEXIBLE CONNECTION
RECTANGULAR FLEXIBLE CONNECTION
NOTE:
NOTE:
DESIGNER’S NOTE:
700 SOUTH 19th STREET 35233
VAMC-BIRMINGHAM, ALABAMALocation:Approved: Service Director
DEPARTMENT OF VETERANS AFFAIRS
MEDICAL CENTER
BIRMINGHAM,ALABAMA
Date
PROJECTS MANAGEMENT
ENGINEERING SERVICE (138)
SCALE:
DRAWING NAME PROJECT NAME: DATE:
DRAWING NUMBER:
FILE:
DRAWN BY:CHECKED BY:
PROJECT NUMBER:
524 West Peachtree St NW
Atlanta GA 30308 t 404 876 3800
Rosser International, Inc.
www.rosser.com
12345678
8 7 6 5 4 3 2 1
G
F
E
D
C
B
A
Revisions
DENTAL RENOVATION &
INCREASE MEDICINE BEDS
521-326
VA 248-C-0838
ROSSER 09076.00
H
G
F
E
D
C
B
A
H
01/06/2012
This drawing and all prints of it are the property of Rosser International, Inc. Prints are to be returned to Rosser International, Inc. upon completion of use for which they were issued.
Reproductions of these drawings without written consent of Rosser International, Inc. is not permitted and Rosser International, Inc. retains all common law, statutory and other reserved rights, including the copyright thereto.
This Record Document has been prepared, in part, based upon construction information furnished by others. While this information is believed to be reliable, Rosser International cannot assure its accuracy, and thus is not responsible for the accuracy of this Record
Document or for any errors or omissions which may have been incorporated into it as a result.AS-BUILT RECORD DRAWING 01/06/2012
A S -B
U
IL
T R
E C
O R
D D
R A
W
IN
G
A S -B
U
IL
T R
E C
O R
D D
R A
W
IN
G
AS-BUILT RECORD DRAWING
AS-BUILT RECORD DRAWING
DETAILS
NONE W. CURRY M6.04
M0604.DGN
WATER COILS - PIPING CONNECTIONS1
NTS
WATER COIL
AIR VENT
WHEN COIL
IS NOT
SELF-VENTING
DRAIN WHEN COIL IS
NOT SELF-DRAINING
TEST PLUG
(TYP.)
PIPE HANGER SHALL SUPPORT
PIPING INDEPENDENT OF COIL
REDUCER, IF REQUIRED
DRAIN
WATER COIL
AIR VENT
WHEN COIL
IS NOT
SELF-VENTING
TEST PLUG
(TYP.)
PIPE HANGER SHALL SUPPORT
PIPING INDEPENDENT OF COIL
WATER COIL
REDUCER, IF REQUIRED
FLOW ELEMENT
DRAIN WHEN COIL IS
NOT SELF-DRAINING
DRAIN
1.
2.
3.
WHEN COIL IS INCLUDED IN CASING MOUNTED ON VIBRATION ISOLATORS THE FIRST
2 HANGERS FOR EACH PIPE SHALL BE SPRING & NEOPRENE TYPE. TYPE "H" FOR
PIPING SHALL BE INSTALLED IN SUCH MANNER THAT IT WILL NOT BLOCK THE
SWING OR USE OF ACCESS DOORS OR PANELS; NEITHER SHALL IT BLOCK THE
SERVICING OF FILTERS, VALES, OR EQUIPMENT.
THE FLOW ELEMENT MAY BE INSTALLED IN THE SUPPLY PIPING IF THE REQUIRED
MINIMUM UPSTREAM AND DOWNSTREAM DIMENSIONS CANNOT BE OBTAINED IN THE
RETURN PIPING.
FE
MV
MV
MV
MV
MVMV
FE
TI
TI
TEMPERATURE
INDICATION TO ECC
SEE CONTROL
DIAGRAM
MV
STEAM COIL - PIPING CONNECTIONS
NTS
1.
2.
3.
4.
5.
WHEN COIL IS INCLUDED IN CASING MOUNTED ON
VIBRATION ISOLATOR UNITS, THE RUNOUT PIPING FOR
CONNECTIONS TO COIL SHALL BE INSTALLED WITH
SWING JOINTS TO ALLOW FOR THE VIBRATION.
PIPING SHALL BE INSTALLED IN SUCH MANNER THAT
IT WILL NOT BLOCK THE SWING OR USE OF ACCESS
DOORS OR PANELS; NEITHER SHALL IT BLOCK THE
SERVICING OF FILTERS, VALVES, OR EQUIPMENT.
TRAP EACH COIL SEPARATELY WHEN INSTALLED IN A
BANK OF TWO OR MORE HIGH. ALSO PROVIDE
SEPARATE VACUUM BREAKER FOR EACH COIL.
TWO TRAP ASSEMBLIES IN PARALLEL ARE SHOWN.
TWO TRAPS REQUIRED WHEN CONDENSATE LOAD IS
5,000 LBS/HR [2400 KG/HR] OR GREATER.
SUPPLY & RETURN PIPES ARE SHOWN FROM SAME
END. REHEAT COIL MAY HAVE SUPPLY & RETURN
PIPES FROM OPPOSITE ENDS.
PIPE HANGER SHALL
SUPPORT PIPING
INDEPENDENT OF COIL
(TYP.)
PITCH COIL DOWN
1/4" [8mm] PER
FOOT TO
CONDENSATE
OUTLET
FULL SIZE
TAPPING
PRESSURE
GAGE
SCALE POCKET
SEE NOTE
NO. 4
STEAM CONDENSATE
RETURN
1/ 2" [15 mm] C
HE
CK
VAL
VE
VAC
UUM
BR
EAK
ER
INCREASER, IF
REQUIRED
REDUCER,
IF REQUIRED
M
IN
m m ]1
M
IN
m m
STEAM SUPPLY
NTS
1.
2.
3.
SECURE CURB CAP TO WOOD NAILING STRIP WITH 3/8" [10mm] CADMIUM PLATED
LAG BOLTS NOT OVER 12" [300mm] ON CENTER.
SECURE ROOF CURB, DUCTWORK AND DAMPER TO ROOF WITH EXPANSION BOLTS
(CONCRETE ROOF) OR RUST RESISTANT BOLTS (METAL DECK AND BAR JOIST
ROOF).
RUN ELECTRICAL LINES THROUGH CLEARANCE HOLE PROVIDED IN GRAVITY DAMPER,
THEN THROUGH VENTILATOR ELECTRICAL CONDUIT GUIDE.
POWER ROOF VENTILATOR
GRAVITY BACKDRAFT DAMPER
RIGID CONDUIT TO
ACCOMMODATE
ELECTRICAL WIRES
SEE NOTE 2
PREFABRICATED
ROOF CURB
WOOD NAILING
STRIP
ELECTRICAL
CONDUIT GUIDE
MOTOR HOUSING
DUCT
TRANSITION DUCT TO
FULL SIZE OF DAMPER
SUPPLIED WITH ROOF
VENTILATOR
ROOF
SEE NOTE 2
SEE NOTE 1
CURB CAP
CORRIDOR
ANTE ROOM
PATIENT ROOM
TOILET ROOM
ROOF
EXHAUST
BLOWER
HEPA FILTER
WITH
GRADE A
PREFILTER
T1
V1 m m
NTS
NEGATIVE ISOLATION ROOM
AIR SYSTEM FOR
dPS
ECC
HS
ITS/A
CV
TERMINAL
UNIT
W/REHEAT
EXHAUST
1.
2.
THE PATIENT BEDROOM IS KEPT UNDER NEGATIVE PRESSURE BY ENSURING AIR MOVEMENT INTO
THE BEDROOM SPACE FROM THE ANTE ROOM AND ADJOINING CORRIDOR.
THE SUPPLY AIR SYSTEM SHALL CONSIST OF THE CONSTANT VOLUME AIR DELIVERY FROM A
DEDICATED AIR TERMINAL UNIT WITH REHEAT COIL (OR A DUCT MOUNTED REHEAT COIL) TO THE
ISOLATION SUITE AS FOLLOWS:
A - PATIENT BEDROOM
B - ANTE ROOM
C - PATIENT TOILET
MINIMUM 12 ACPH SUPPLY AIR (ASHRAE 2007 HANDBOOK OF
APPLICATIONS). INCREASE SUPPLY AIR VOLUME, IF REQUIRED, TO
MEET THE INSIDE DESIGN CONDITIONS IN COOLING AND/OR HEATING
MODES. EXAMPLE: 400 CFM
MINIMUM 10 ACPH SUPPLY AIR (ASHRAE 2007 HANDBOOK OF
APPLICATIONS) OR MINIMUM 100 CFM. EXAMPLE: 100 CFM
DO NOT SUPPLY AIR INTO THE TOILET. DRAW MAKE-UP AIR FROM
THE PATIENT’S BEDROOM AND EXHAUST AT THE RATE OF 10 ACPH
OR 60 CFM. EXAMPLE: 60 CFM
THE DEDICATED EXHAUST AIR SYSTEM SHALL BE BALANCED AS FOLLOWS:
A - PATIENT BEDROOM
3.
3287.85m10’-0" MIN
M6.04
M6.04
M6.04
M6.04
T1
LEGEND
V1
ROOM THERMOSTAT TO CONTROL
COOLING AND HEATING, INCLUDING
PERIMETER HEAT (IF ANY)
AIR FLOW CONTROL VALVES
PRESSURE INDEPENDENT TYPE
400 CFM (SUPPLY) - 75 CFM (TOILET) + 75 CFM (ANTE ROOM)
+ 10% =440 CFM (EXHAUST)
NEW EXISTING
SINGLE COIL
DOUBLE COIL
NOTE:
NOTE:
TYPICAL AIR BALANCE EXAMPLE:
700 SOUTH 19th STREET 35233
VAMC-BIRMINGHAM, ALABAMALocation:Approved: Service Director
DEPARTMENT OF VETERANS AFFAIRS
MEDICAL CENTER
BIRMINGHAM,ALABAMA
Date
PROJECTS MANAGEMENT
ENGINEERING SERVICE (138)
SCALE:
DRAWING NAME PROJECT NAME: DATE:
DRAWING NUMBER:
FILE:
DRAWN…
This is the start of the file's text. The full file is on GovTribe.