Mechanical- Dental.pdf

PDF 7 MB Posted

Attached to
J045-- 521-24-3-5125-0022-HVAC & MEDICAL AIR/VACUUM SYSTEMS MAINTENANCE
Solicitation number
36C24724Q0633
Issued by

About this file

This document is a Combined Synopsis/Solicitation for commercial services for Heating, Ventilation, and Air Conditioning (HVAC), medical air/vacuum systems, and plumbing maintenance and repair services at the Department of Veterans Affairs (VA) Medical Center in Birmingham, Alabama. The solicitation is a 100% Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside with a base period and four option years. The required services include preventative maintenance, repair, and emergency services for the facility's HVAC, steam, and medical air/vacuum systems. The solicitation provides details on the evaluation factors, which include technical capability, past performance, and price. Offerors are required to submit quotes/offers by May 28, 2024, and a site visit is scheduled for May 14, 2024. The contract will use the prevailing wage rates from the attached Davis-Bacon Wage Determination.

View the file

Other files

File Type Posted
41-M0.1- Gas Boiler.pdf PDF
Mechanical-Heart Station.pdf PDF
lattner instruction manual space saver july 2020.pdf PDF
Mechanical-ORs.pdf PDF
Mechanical-Ambulatory Clinic.pdf PDF
Mechanical- Sterile Processing.pdf PDF
AC6B-Heart Station AHU.pdf PDF
Futera Fusion 750 Interactive Submittal Data Sheet SFTF 750 7_1.pdf PDF
36C24724Q0633_3.docx DOCX document
49-M4.1-Gas boiler.pdf PDF
Mechanical- Pharmacy.pdf PDF
Updated Attachment A _ Revised May 27 2024.pdf PDF
36C24724Q0633_2.docx DOCX document
STATEMENT OF WORK.pdf PDF
SCHEDULE.docx DOCX document
Site Visit Map.pdf PDF
Wage Determination No 2015-4591 Rev 25.pdf PDF
36C24724Q0633_1.docx DOCX document
Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Building Number

700 SOUTH 19th STREET 35233

VAMC-BIRMINGHAM, ALABAMALocation:Approved: Service Director

DEPARTMENT OF VETERANS AFFAIRS

MEDICAL CENTER

BIRMINGHAM,ALABAMA

Date

PROJECTS MANAGEMENT

ENGINEERING SERVICE (138)

SCALE:

DRAWING NAME PROJECT NAME: DATE:

DRAWING NUMBER:

FILE:

DRAWN BY:CHECKED BY:

PROJECT NUMBER:

524 West Peachtree St NW

Atlanta GA 30308 t 404 876 3800

Rosser International, Inc.

www.rosser.com

12345678

8 7 6 5 4 3 2 1

G

F

E

D

C

B

A

Revisions

DENTAL RENOVATION &

INCREASE MEDICINE BEDS

521-326

VA 248-C-0838

ROSSER 09076.00

H

G

F

E

D

C

B

A

H

01/06/2012

This drawing and all prints of it are the property of Rosser International, Inc. Prints are to be returned to Rosser International, Inc. upon completion of use for which they were issued.

Reproductions of these drawings without written consent of Rosser International, Inc. is not permitted and Rosser International, Inc. retains all common law, statutory and other reserved rights, including the copyright thereto.

This Record Document has been prepared, in part, based upon construction information furnished by others. While this information is believed to be reliable, Rosser International cannot assure its accuracy, and thus is not responsible for the accuracy of this Record

Document or for any errors or omissions which may have been incorporated into it as a result.AS-BUILT RECORD DRAWING 01/06/2012

A S -B

U

IL

T R

E C

O R

D D

R A

W

IN

G

A S -B

U

IL

T R

E C

O R

D D

R A

W

IN

G

AS-BUILT RECORD DRAWING

AS-BUILT RECORD DRAWING

LEGEND, ABBREVIATIONS

& GENERAL NOTES

NONE W. CURRY M0.01

M0701.DGN

GENERAL NOTES:

G1. COORDINATE ALL WORK WITH OTHER TRADES PRIOR TO INSTALLATION.

G3. DUCT SIZES SHOWN ARE ACTUAL INSIDE DIMENSIONS.

G4. OPEN ENDS OF TRANSFER AIR DUCTS AND RETURN AIR DUCTS 18" AND LARGER IN

EITHER DIMENSION SHALL BE REINFORCED WITH 1�"x 1�"x 20 GAUGE ANGLES

ON ALL SIDES. SECURE ANGLES TO DUCT WITH SHEET METAL SCREWS MAXIMUM 12

INCHES ON CENTER

G6. RETURN AIR PLENUMS AT AIR HANDLING EQUIPMENT SHALL BE FULL SIZE OF UNIT

INLET.

G7. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF GRILLES

AND DIFFUSERS IN CEILINGS.

G8. RUNOUTS TO AIR DISTRIBUTION DEVICES SHALL BE NOMINAL NECK SIZE OF AIR

DISTRIBUTION DEVICE UNLESS NOTED OTHERWISE. ROUND RUNOUTS OVER GYPBOARD

OR PLASTER CEILINGS SHALL BE RIGID.

G9. ALL SUPPLY RUNOUTS, BRANCH DUCTS, OR TAKE-OFFS TO AIR DISTRIBUTION DEVICES

SHALL BE PROVIDED WITH MANUAL DAMPERS. ROUND DUCTS SHALL BE CONNECTED TO

RECTANGULAR DUCTS WITH ROUND BRANCH TAKE-OFFS. RECTANGULAR RUNOUTS AND

BRANCH TAKE-OFFS SHALL BE CONNECTED TO RECTANGULAR DUCT WITH 45 ENTRY

FITTING AND VOLUME DAMPER.

o

12" LONG FLANGED &

GASKETED DUCT SECTION

6 X 8 ACCESS DOOR

12 X 12 ACCESS DOOR

18 X 12 ACCESS DOOR

10" & SMALLER

12" TO 15"

16" TO 24"

25" & LARGER

24 X 24

G10. UNLESS NOTED OTHERWISE, ACCESS SHALL BE PROVIDED ADJACENT TO ALL MOTOR

OPERATED DAMPERS, FIRE DAMPERS, SMOKE DAMPERS, AND COMBINATION FIRE/SMOKE

DAMPERS AS FOLLOWS:

DUCT SIZE (INCHES) DUCT ACCESS (INCHES) CEILING ACCESS PANEL (INCHES)

G11. THE FOLLOWING IS USED TO IDENTIFY THE AIR DISTRIBUTION DEVICES:

10" n CD

300 CFM

TYP OF 2

NECK SIZE TYPE OF DEVICE (CD, ER, ETC.)

AIRFLOW NUMBER TYPICAL

G12. PROVIDE TRANSITION TO VAV BOX INLET WHERE INLET SIZE DIFFERS FROM RUNOUT

SIZE. TRANSITION SHALL OCCUR AT INLET.

G13. ALL HOT WATER PIPING RUNOUTS TO TERMINAL UNITS SHALL BE �" UNLESS OTHERWISE

NOTED.

PLANS. SEE ELECTRICAL PLANS FOR VOLTAGE AND PHASE REQUIREMENTS BEFORE

SUBMITTING AND ORDERING MECHANCIAL EQUIPMENT.

G5. ELECTRICAL CHARACTERISTICS OF EQUIPMENT ARE NOT SHOWN ON THE MECHANICAL

G2. UNLESS OTHERWISE INDICATED, INSTALL ALL SPACE THERMOSTATS 48 INCHES

ABOVE FINISHED FLOOR.

A/C

ACU

AD

AHU

BTUH

CD

CFM

CLG

CO

CONC

CONN

CONT

CU

DG

DN

DOM

DS

DWGS

EA

EDH

EF

EG

ELEC

ER

EXH

EXIST

FCU

FPB

GPM

HWC

HVAC

LD

MAX

MIN

OA

OC

RA

RG

RR

RTU

SG SUPPLY AIR GRILLE

SMD SMOKE DAMPER

SR SUPPLY AIR REGISTER

TG TRANSFER GRILLE

TYP TYPICAL

UH UNIT HEATER

VAV VARIABLE AIR VOLUME UNIT

WITH

WALL HEATER

WALL OPENING

AFF

EL

SKD

SPS

WH

WO

W/

SMOKE DETECTOR

STATIC PRESSURE SENSOR

DOOR GRILLE

DOWN

DOMESTIC

DUCT SILENCER

DRAWINGS

EACH

ELECTRIC DUCT HEATER

EXHAUST FAN

EXHAUST AIR GRILLE

ELECTRIC

EXHAUST AIR REGISTER

EXHAUST

EXISTING

FAN COIL UNIT

FAN POWERED BOX

GALLONS PER MINUTE

HOT WATER COIL

HEATING VENTILATING & AIR CONDITIONING

LINEAR DIFFUSER

MAXIMUM

MINIMUM

OUTSIDE AIR

ON CENTER

RETURN AIR

RETURN AIR GRILLE

RETURN AIR REGISTER

ROOFTOP UNIT

ELEVATION

CONDENSING UNIT

ABOVE CEILING

AIR CONDITIONING UNIT

DUCT ACCESS DOOR

AIR HANDLING UNIT

BRITISH THERMAL UNITS PER HOUR

CEILING DIFFUSER

CUBIC FEET PER MINUTE

CEILING

CLEAN OUT

CONCRETE

CONNECT

CONTINUATION

ABOVE FINISHED FLOOR

CONDENSATE DRAIN CD

HOT WATER SUPPLY HWS

HOT WATER RETURN HWR

REFRIGERANT LIQUID RL

REFRIGERANT SUCTION RS

REFRIGERANT GAS RG

CHILLED WATER SUPPLY CHS

CHILLED WATER RETURN CHR

RG

RS

RL

HWR

HWS

CHR

CHS

CD

ABBREVIATION DESCRIPTIONSYMBOL ABBREVIATION DESCRIPTION

LEGEND & ABBREVIATIONS

PIPING

DUCTWORK

PIPE UP

PIPE DOWN

PIPE BRIDGE

EXISTING DUCT & EQUIP ON DEMOLITION PLANS

FLEXIBLE DUCT

DUCT TRANSITION

AIR EXTRACTER

DUCT DOWN

DUCT UP

TURNING VANES

DIRECTION OF FLOW

DAMPERS

SD

BRANCH SPLITTER

MLD/MD MANUAL DAMPER

MOD MOTOR OPERATED DAMPER

SMD SMOKE DAMPER

SPLITTER DAMPER

CONTROLS

T’STAT THERMOSTAT T

CONNECT TO EXISTING

MISCELLANEOUS

ROUND

FO FLAT OVAL

n

FD FIRE DAMPER

M

S

VALVES / FITTINGS / SPECIALTIES

FSD

HPU

FSD

UNO UNLESS NOTED OTHERWISE

HEAT PUMP UNIT

FIRE/SMOKE DAMPER

EXISTING DUCT & EQUIP ON NEW PLANS

SINGLE LINE DUCT

G14. AUTOMATIC AIR VENTS ON TOP OF AIR SEPARATORS SHALL BE PIPED FULL SIZE TO

FLOOR DRAIN.

INSIDE OUTSIDE

HEAT.HEAT. COOLING COOLING

DB F DB F DB F DB FWB F WB F

BUILDING AREA

DESIGN CONDITIONS

HOSPITAL OCCUPIED AREAS 70 75 63 21 94 75

PULL CLO.

T.

1 2

F.H.C.

STAIR 3

Building Number

700 SOUTH 19th STREET 35233

VAMC-BIRMINGHAM, ALABAMALocation:Approved: Service Director

DEPARTMENT OF VETERANS AFFAIRS

MEDICAL CENTER

BIRMINGHAM,ALABAMA

Date

PROJECTS MANAGEMENT

ENGINEERING SERVICE (138)

SCALE:

DRAWING NAME PROJECT NAME: DATE:

DRAWING NUMBER:

FILE:

DRAWN BY:CHECKED BY:

PROJECT NUMBER:

524 West Peachtree St NW

Atlanta GA 30308 t 404 876 3800

Rosser International, Inc.

www.rosser.com

12345678

8 7 6 5 4 3 2 1

G

F

E

D

C

B

A

Revisions

DENTAL RENOVATION &

INCREASE MEDICINE BEDS

521-326

VA 248-C-0838

ROSSER 09076.00

H

G

F

E

D

C

B

A

H

01/06/2012

This drawing and all prints of it are the property of Rosser International, Inc. Prints are to be returned to Rosser International, Inc. upon completion of use for which they were issued.

Reproductions of these drawings without written consent of Rosser International, Inc. is not permitted and Rosser International, Inc. retains all common law, statutory and other reserved rights, including the copyright thereto.

This Record Document has been prepared, in part, based upon construction information furnished by others. While this information is believed to be reliable, Rosser International cannot assure its accuracy, and thus is not responsible for the accuracy of this Record

Document or for any errors or omissions which may have been incorporated into it as a result.AS-BUILT RECORD DRAWING 01/06/2012

A S -B

U

IL

T R

E C

O R

D D

R A

W

IN

G

A S -B

U

IL

T R

E C

O R

D D

R A

W

IN

G

AS-BUILT RECORD DRAWING

AS-BUILT RECORD DRAWING

N

1 1 1 1 1 1

1 3

1 3

1 3

6th FLOOR DEMOLITION PLAN M2.02

SCALE: �"=1’-0"

1.

2.

3.

4.

5.

6.

7.

VERIFY ALL DIMENSIONS PRIOR TO BEGINNING WORK. NOTIFY ARCHITECT

IMMEDIATELY OF ANY DISCREPANCIES.

WHERE EXISTING MATERIALS ARE INDICATED TO BE REMOVED, SURFACES AND

EDGES SHALL BE SUITABLE FOR THE INSTALLATION OF NEW WORK. REMOVE

PAINT, DUST, MASTIC, MORTAR, FASTENERS, ETC. WHICH WILL BE DETRIMENTAL

TO THE INSTALLATION OF NEW MATERIALS.

PREVENT DAMAGE TO EXISTING MATERIALS TO REMAIN. PREVENT DAMAGE TO

EXISTING MATERIALS TO BE REMOVED AND RELOCATED OR REINSTALLED.

REMOVE ALL ABANDONED PIPING AND PIPING ACCESSORIES. PROVIDE PERMANENT

AND TEMPORARY SEALS OVER OPEN ENDS OF ALL PIPING TO REMAIN.

ITEMS TO BE REMOVED

COORDINATE DEMOLITION WORK WITH NEW LAYOUT. COORDINATE WORK WITH

DEMOLITION AND NEW WORK SHOWN ON MECHANICAL, ELECTRICAL AND

PLUMBING DRAWINGS.

6 NO WORK THIS AREA

EXISTING CHILLED WATER PIPING ABOVE CEILING TO REMAIN.

EXISTING OUTSIDE AIR DUCTWORK MAIN TRUNK ABOVE CEILING TO REMAIN. REMOVE

ALL BRANCH DUCTS; CAP AND SEAL DUCT

EXISTING STEAM AND CONDENSATE RETURN PIPING ABOVE CEILING TO REMAIN

REMOVE EXISTING FAN COIL UNIT, SUPPLY AND RETURN DUCTWORK AND

AIR DEVICES. CLOSE SERVICE VALVES ON CHILLED WATER, STEAM AND CONDENSATE

RETURN PIPING. REMOVE PIPING AND DEVICES ON COIL SIDE OF VALVES. VALVES

SHALL BE REUSED IN FUTURE AND NEW PIPING ATTACHED. REMOVE

THERMOSTAT AND ASSOCIATED CONTROL WIRING.

2 2 2

3 3

3 3

4 4

7 7

N KEY PLAN

EXISTING EXHAUST DUCT TO BE REMOVED. CAP AND SEAL AT EDGE OF CONSTRUCTION

BOUNDRY.

EXSTING TO REMAIN

CONTRACTOR TO PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, DELIVERY, OVERHEAD

AND OTHER ITEMS NECCESSARY TO ACCOMPLISH THE WORK.

HAUL OFF AND LAWFULLY DISPOSE OF ALL DEMOLISHED MATERIAL TO OFF SITE LOCATION

LIMITS OF WORK

REMOVE HORIZONTAL DUCTWORK LABELED AS "HAZARDOUS" CAP AND SEAL

AT SHAFT PENETRATION

THE OWNER IS TO BE GIVEN A MINIMUM OF 72 HOURS ADVANCE NOTICE ON ALL

UTILITY OUTAGES. A 5 DAY MINIMUM ADVANCE NOTICE IS REQUIRED ON ALL

MAJOR UTILITY OUTAGES.

NO UTILITIES OR SYSTEMS ARE TO BE TAKEN OFF LINE, TERMINATED OR ALTERED

WITHOUT THE OWNER’S PRIOR KNOWLEDGE & APPROVAL.

8.

9.

6th FLOOR

MECHANICAL

DEMOLITION PLAN

�"=1’-0" JTA W. CURRY M2.02

M0202.DGN

GENERAL DEMOLITION NOTES

DEMOLITION KEYNOTES

LEGEND

F.H.C.

ELECTROMECH

LOLOTOSHO

LOLOTOSHO1507D

OFFICE

1507C

OFFICE

1507E

OFFICE

1507F

OFFICE

1507G

OFFICE

1507H

OFFICE

OFFICE

1507A

OFFICE

1507B

OFFICE

15291530

OFFICE

ELECTROMECH

LOLOTOSHO

EXAM

EXAM

EXAM

EXAM

OFFICE

CONFERENCE STAIR #5

NUCLEAR MEDICINE SERVICE

TREATMENT

E X

IT

E X

IT

E X

IT

EXIT

Building Number

700 SOUTH 19th STREET 35233

VAMC-BIRMINGHAM, ALABAMALocation:Approved: Service Director

DEPARTMENT OF VETERANS AFFAIRS

MEDICAL CENTER

BIRMINGHAM,ALABAMA

Date

PROJECTS MANAGEMENT

ENGINEERING SERVICE (138)

SCALE:

DRAWING NAME PROJECT NAME: DATE:

DRAWING NUMBER:

FILE:

DRAWN BY:CHECKED BY:

PROJECT NUMBER:

524 West Peachtree St NW

Atlanta GA 30308 t 404 876 3800

Rosser International, Inc.

www.rosser.com

12345678

8 7 6 5 4 3 2 1

G

F

E

D

C

B

A

Revisions

DENTAL RENOVATION &

INCREASE MEDICINE BEDS

521-326

VA 248-C-0838

ROSSER 09076.00

H

G

F

E

D

C

B

A

H

01/06/2012

This drawing and all prints of it are the property of Rosser International, Inc. Prints are to be returned to Rosser International, Inc. upon completion of use for which they were issued.

Reproductions of these drawings without written consent of Rosser International, Inc. is not permitted and Rosser International, Inc. retains all common law, statutory and other reserved rights, including the copyright thereto.

This Record Document has been prepared, in part, based upon construction information furnished by others. While this information is believed to be reliable, Rosser International cannot assure its accuracy, and thus is not responsible for the accuracy of this Record

Document or for any errors or omissions which may have been incorporated into it as a result.AS-BUILT RECORD DRAWING 01/06/2012

A S -B

U

IL

T R

E C

O R

D D

R A

W

IN

G

A S -B

U

IL

T R

E C

O R

D D

R A

W

IN

G

AS-BUILT RECORD DRAWING

AS-BUILT RECORD DRAWING

REMOVEABLE

HATCHES OVER

TRANSFORMER

N

ITEMS TO BE REMOVED

ITEMS TO REMAIN

1 1

1 1

1st FLOOR DEMOLITION PLAN M2.03

SCALE: �"=1’-0"

2nd FLOOR DEMOLITION PLAN M2.03

SCALE: �"=1’-0"

N

1 1

1 1

1 1

1 1 1

1 1

1 1

1 1

1 1

1 1

1 1

N

6 NO WORK THIS AREA

6 6

LIMITS OF CONSTRUCTION

LIMITS OF CONSTRUCTION

LIMITS OF CONSTRUCTION

LIMITS OF CONSTRUCTION 1

1 1

1.

2.

3.

4.

5.

6.

7.

VERIFY ALL DIMENSIONS PRIOR TO BEGINNING WORK. NOTIFY ARCHITECT

IMMEDIATELY OF ANY DISCREPANCIES.

WHERE EXISTING MATERIALS ARE INDICATED TO BE REMOVED, SURFACES AND

EDGES SHALL BE SUITABLE FOR THE INSTALLATION OF NEW WORK. REMOVE

PAINT, DUST, MASTIC, MORTAR, FASTENERS, ETC. WHICH WILL BE DETRIMENTAL

TO THE INSTALLATION OF NEW MATERIALS.

PREVENT DAMAGE TO EXISTING MATERIALS TO REMAIN. PREVENT DAMAGE TO

EXISTING MATERIALS TO BE REMOVED AND RELOCATED OR REINSTALLED.

REMOVE ALL ABANDONED PIPING AND PIPING ACCESSORIES. PROVIDE PERMANENT

AND TEMPORARY SEALS OVER OPEN ENDS OF ALL PIPING TO REMAIN.

COORDINATE DEMOLITION WORK WITH NEW LAYOUT. COORDINATE WORK WITH

DEMOLITION AND NEW WORK SHOWN ON MECHANICAL, ELECTRICAL AND

PLUMBING DRAWINGS.

CONTRACTOR TO PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, DELIVERY, OVERHEAD

AND OTHER ITEMS NECCESSARY TO ACCOMPLISH THE WORK.

HAUL OFF AND LAWFULLY DISPOSE OF ALL DEMOLISHED MATERIAL TO OFF SITE LOCATION

THE OWNER IS TO BE GIVEN A MINIMUM OF 72 HOURS ADVANCE NOTICE ON ALL

UTILITY OUTAGES. A 5 DAY MINIMUM ADVANCE NOTICE IS REQUIRED ON ALL

MAJOR UTILITY OUTAGES.

NO UTILITIES OR SYSTEMS ARE TO BE TAKEN OFF LINE, TERMINATED OR ALTERED

WITHOUT THE OWNER’S PRIOR KNOWLEDGE & APPROVAL.

8.

9.

DENTAL CLINIC - 1st & 2nd FLOOR

HVAC

DEMOLITION PLANS

�"=1’-0" J.AKERS W.CURRY M2.03

M0203.DGN

REMOVE EXISTING DUCTWORK, PIPING, AND VAV BOXES

EXISTING DUCT PENETRATIONS THROUGH WALL TO REMAIN,

FIRE DAMPER ( IF PRESENT) SHALL ALSO REMAIN

FUME HOOD EXHAUST DUCT AND CONTROLS TO REMAIN

REMOVE GRILLE FROM WALL, PATCH AND SEAL

1 1

1 1

WORK IN THIS AREA UNDER SEPARATE CONTRACT

REMOVE EXISTING, AHU, DUCTWORK AND FANS.

PIPING THROUGH ROOM SHALL REMAIN

1 1 1 1 1 1

DEMOLITION KEYNOTES

KEY PLAN

LEGEND

GENERAL DEMOLITION NOTES

A B C D E F

LOLOTOSHO

LOLOTOSHO

1507E

VOLUNTEER

ELECTROMECH

OFFICE

OFFICE

REMOVEABLE

HATCHES OVER

TRANSFORMER

E X

IT

EXIT

EXIT

EXIT

Building Number

700 SOUTH 19th STREET 35233

VAMC-BIRMINGHAM, ALABAMALocation:Approved: Service Director

DEPARTMENT OF VETERANS AFFAIRS

MEDICAL CENTER

BIRMINGHAM,ALABAMA

Date

PROJECTS MANAGEMENT

ENGINEERING SERVICE (138)

SCALE:

DRAWING NAME PROJECT NAME: DATE:

DRAWING NUMBER:

FILE:

DRAWN BY:CHECKED BY:

PROJECT NUMBER:

524 West Peachtree St NW

Atlanta GA 30308 t 404 876 3800

Rosser International, Inc.

www.rosser.com

12345678

8 7 6 5 4 3 2 1

G

F

E

D

C

B

A

Revisions

DENTAL RENOVATION &

INCREASE MEDICINE BEDS

521-326

VA 248-C-0838

ROSSER 09076.00

H

G

F

E

D

C

B

A

H

01/06/2012

This drawing and all prints of it are the property of Rosser International, Inc. Prints are to be returned to Rosser International, Inc. upon completion of use for which they were issued.

Reproductions of these drawings without written consent of Rosser International, Inc. is not permitted and Rosser International, Inc. retains all common law, statutory and other reserved rights, including the copyright thereto.

This Record Document has been prepared, in part, based upon construction information furnished by others. While this information is believed to be reliable, Rosser International cannot assure its accuracy, and thus is not responsible for the accuracy of this Record

Document or for any errors or omissions which may have been incorporated into it as a result.AS-BUILT RECORD DRAWING 01/06/2012

A S -B

U

IL

T R

E C

O R

D D

R A

W

IN

G

A S -B

U

IL

T R

E C

O R

D D

R A

W

IN

G

AS-BUILT RECORD DRAWING

AS-BUILT RECORD DRAWING

128127

111 112

129 130

124123

106 107 108

H W

R

HWS

HWR

H W

S

H W

R

HWR

HWS

H W

S

H W

R

HWS

H W

S

N

N

DENTAL CLINIC

1st FLOOR - HVAC

RENOVATION PLAN

�"=1’-0" J.AKERS W.CURRY M3.01

M0301.DGN

1st FLOOR RENOVATION PLAN-HVAC M3.01

SCALE: �"=1’-0"

LIMITS OF WORK

LIMITS OF WORK

n 8" CD

210 CFM

n 8" CD

210 CFM

n 8" CD

210 CFM

n 8" CD

210 CFM

n 8" CD

210 CFM

n 8" CD

210 CFM

n 8" CD

210 CFM

n 8" CD

210 CFM

10X8 SR

25 CFM

n10" CD

300 CFM

n10" CD

300 CFM

n10" CD

300 CFM

n10" CD

300 CFM

n 8" CD

200 CFM

n 6" CD

135 CFM

n 6" CD

25 CFM

n10" CD

240 CFM

n10" CD

240 CFM

n10" CD

240 CFM

n10" CD

250 CFM

n 8" CD

140 CFM

n 8" CD

140 CFM

n 8" CD

150 CFM

n 8" CD

150 CFM

n 6" CD

110 CFM

n 8" CD

165 CFM

n 8" CD

165 CFM

n 8" CD

165 CFM

n 8" CD

165 CFM

n 8" CD

165 CFM

n 6" CD

50 CFM

n 6" CD

100 CFM

n 8" CD

155 CFM

n 8" CD

155 CFM

n 8" CD

155 CFM

n 8" CD

165 CFM

n 8" CD

150 CFM

n 6" CD

80 CFM

12X12 20X14 36X14

X

8X8 EG

100 CFM

8X8 EG

100 CFM

20X20 EG

780 CFM

20X20 EG

780 CFM

X

20X1224X14

8X8 EG

130 CFM

8X6

X

8X6

10X10 EG

130 CFM

10X10 EG

130 CFM

RG

RG

RG

RG

RG

n 8" CD

205 CFM

12X12 EG

190 CFM

12X12 EG

200 CFM

10X6

10X6

10X6

10X6

10X6

NOTES:

1 ROUTE DUCT FULL SIZE OF DIFFUSER NECK CONNECTION TO DUCT

WITH BALANCING DAMPER

X

14X10 16X10

18X10

X

X

14X10

22X12

X

12X6

X

24X12

30X12

34X16

15 CFM

120 CFM

34X22

80 CFM

80 CFM

85 CFM

85 CFM

105 CFM

95 CFM

90 CFM

105 CFM

105 CFM

105 CFM

14X12

X

X

X

X

10X8 10X8

14X12

X

10X10

X

X

X

8X12

X

14X1210X12

X

10X12

10X8

24X1214X1010X10

10X6

10X6 n 4" n 4"

1"

1"

1"

1�"

2"

1�"1�"

2"

1�"

1"

2"

2"

12X10 WALL OPENING

ABOVE CEILING

OPEN TO RETURN

PLENUM, BALANCE

TO 565 CFM

16X12

2 12X6 DOWN IN CHASE. INSTALL EXHAUST GRILLE WITHIN 6" AFF

10X10 WEG

190 CFM

10X10 WEG

190 CFM

12X6

12X8

CHILLED WATER COOLING COIL

STEAM PRE-HEAT

X

20X10 DOWN IN CHASE

8X30 WEG

960 CFM

WITHIN 6" AFF

CONNECT TO EXISTING

LOUVER FOR OUTDOOR AIR

INTAKE

10X8 SR

25 CFM

EXTEND 6X6 EXHAUST DUCT INTO ROOM AND DOWN

THROUGH RATED CEILING WITH FIRE DAMPER AND

ACCESS DOOR. INSTALL BALANCING DAMPER IN DROP,

SET TO 50 CFM. EXTEND DUCT DOWN TO WITHIN 12"

ABOVE FINISHED FLOOR WITH 1/4"X1/4" HARDWARE CLOTH

12X10 WALL

OPENING

ABOVE CEILING34X12

12X6 20X10

10X10 WEG

165 CFM

12X6

X

10X10 WEG

160 CFM

10X6

50 CFM

12X6

CONDENSATE DOWN

61X14

FILTER MIXING BOX WITH

TOP RELIEF AND BACK RETURN

SUPPLY FAN

ECONOMIZER SECTION WITH TOP

OUTSIDE AIR AND AIRLFLOW STATION

CONNECT TO EXISTING

LOUVER FOR OUTDOOR AIR INTAKE

CONNECT TO

EXISTING DUCT

FOR RELIEF AIR DISCHARGE

SUPPLY PLENUM WITH VERTICAL DISCHARGE

90%-95% FINAL FILTER WITH

MERV 8 PREFILTER

X

STEAM PIPE

CHILLED

WATER

PIPES

VFD

X

28X20

50X20

36X24

15 CFM

X

CONDENSATE

RETURN FROM

ABOVE.

105 CFM

n 8"

12X10 WALL

OPENING

ABOVE CEILING

8X8 EG

100 CFM

10X8 SR

25 CFM10X10 EG

130 CFM

10X10 EG

125 CFM

10X10 EG

125 CFM

10X10 EG

125 CFM

10X10 EG

130 CFM

8X8 EG

100 CFM

10X10 EG

130 CFM

10X10 EG

130 CFM

HAC

STORAGE

BREAK

X-RAY

RECEPTION

RADIOGRAPH

STORAGE

TOILETTOILET

ELEV. #1

ELEV. #2

WAITING

TOILET

TOILET

STAIR

CORRIDOR

CORRIDOR

C O

R R

ID

O R

C O

R R

ID

O R

OPERATIVE

OPERATIVE

HYGIENE

HYGIENE

FUTURE ORAL

SURGERY

ORAL

SURGERY

ORAL

SURGERY

ORAL

SURGERY

ORAL

SURGERYORAL

DIAGNOSIS

ORAL

DIAGNOSIS

PERIODONTAL

PERIODONTAL

PERIODONTAL

ENDODONTICS

ENDODONTICS

NOS

ELECT.

KEY PLAN

VAV-1/06VAV-1/07

VAV-1/08

VAV-1/10

VAV-1/05

VAV-1/03

VAV-1/04

VAV-1/11

AHU-1

VAV-1/02

VAV-1/01

VAV-1/09

1 2

F.H.C.

STAIR 3

AC BA

C

BA

C

BA

C

C

C

BA

C

BA

C

A

Building Number

700 SOUTH 19th STREET 35233

VAMC-BIRMINGHAM, ALABAMALocation:Approved: Service Director

DEPARTMENT OF VETERANS AFFAIRS

MEDICAL CENTER

BIRMINGHAM,ALABAMA

Date

PROJECTS MANAGEMENT

ENGINEERING SERVICE (138)

SCALE:

DRAWING NAME PROJECT NAME: DATE:

DRAWING NUMBER:

FILE:

DRAWN BY:CHECKED BY:

PROJECT NUMBER:

524 West Peachtree St NW

Atlanta GA 30308 t 404 876 3800

Rosser International, Inc.

www.rosser.com

12345678

8 7 6 5 4 3 2 1

G

F

E

D

C

B

A

Revisions

DENTAL RENOVATION &

INCREASE MEDICINE BEDS

521-326

VA 248-C-0838

ROSSER 09076.00

H

G

F

E

D

C

B

A

H

01/06/2012

This drawing and all prints of it are the property of Rosser International, Inc. Prints are to be returned to Rosser International, Inc. upon completion of use for which they were issued.

Reproductions of these drawings without written consent of Rosser International, Inc. is not permitted and Rosser International, Inc. retains all common law, statutory and other reserved rights, including the copyright thereto.

This Record Document has been prepared, in part, based upon construction information furnished by others. While this information is believed to be reliable, Rosser International cannot assure its accuracy, and thus is not responsible for the accuracy of this Record

Document or for any errors or omissions which may have been incorporated into it as a result.AS-BUILT RECORD DRAWING 01/06/2012

A S -B

U

IL

T R

E C

O R

D D

R A

W

IN

G

A S -B

U

IL

T R

E C

O R

D D

R A

W

IN

G

AS-BUILT RECORD DRAWING

AS-BUILT RECORD DRAWING

M

M

N

N

PATIENT UNIT

6th FLOOR

RENOVATION PLAN

�"=1’-0" W. CURRY M3.03

M0303.DGN

NOTES:

6th FLOOR RENOVATION PLAN - HVAC DUCTWORK M3.03

SCALE: �"=1’-0"

n12" CD

400 CFM

n12" CD

400 CFM

n10" CD

300 CFM

n 6" CD

75 CFM

n 6" CD

50 CFM

10X6 SG

50 CFM

n 6" n10" n10" n 6" n 8"

TYP

16X10 n10"n10" CD

315 CFM

n 8" CD

190 CFM

TYP OF 3

n 8" n 6" CD

75 CFM

n 6" n 8" CD

165 CFM

TYP OF 2

n 8" CD

165 CFM

TYP OF 3

n 8" n 6"

10X6 SG

50 CFM

1 1

X n 8"

10X10 n 6" CD

60 CFM

n 6" CD

130 CFM

TYP OF 2

X n 6"

14X12 n10" CD

300 CFM

n 6" n12" CD

400 CFM

n 6" n10" n 6"

8X8 ER

75 CFM

X

X

14X14 ER

220 CFM

8X6

8X8 ER

75 CFM

VAV-6BS1

VAV-6BS2

n 6" CD

75 CFM

n12" CD

400 CFM

n12" CD

400 CFM

n 6" CD

75 CFM

n 6"

10X6 SG

50 CFM

1 1

X

10X6 SG

50 CFM

n12" CD

400 CFM

n10" n 6" n10"

10X6 SG

50 CFM

n 6" n12" CD

400 CFM

n10" n 6"

10X6 SG

50 CFM

14X10 n12" CD

400 CFM

n10" n 6"

10X6 SG

50 CFM

n12" CD

400 CFM

n10"

10X6 SG

50 CFM

n 6"

14X10 n 6"

10X6 SG

50 CFM

n12" CD

200 CFM

n10" n10" n12" CD

200 CFM

n12" CD

200 CFM

n12" CD

200 CFM

n10" n 6"10X6 SG

50 CFM

n10" 14X10 n12" CD

400 CFM

n10" n 6" n12" CD

400 CFM

n10"

INSTALL 24" DEEP RETURN PLENUM AND 12" DEEP SUPPLY PLENUM ON UNIT.

SIZE SHALL MATCH UNIT CONNECTION.

FILTER RETURN GRILLES (FRG) SHALL HAVE FILTER SIZE TO

MATCH HOSPITAL STANDARD. SIZE SHOWN IS NECK SIZE.

PRESSURE INDEPENDENT AIRFLOW CONTROL VALVE, CONTROLLED BY ISOLATION

ROOM PRESSURE CONTROLLER.

ISOLATION ROOM PRESSURE CONTROLLER, OPERATION AND

FUNCTIONS SHALL MATCH FIFTH FLOOR.

INSTALL 24X36 FIRE RATED ACCESS DOOR IN SHAFT.

605 604

625627

632631

621 623

ISOLATION

ISOLATION

X

X

6X4

6X4

6X4

6X4

6X4

6X46X4

6X4

6X4

X

X

X

8X8 EG

75 CFM

X

8X4

8X4

X

8X612X6 16X816X10

EXTEND 22X10 EA DUCT BACK TO

EXISTING EXHAUST FAN; REBALANCE

EA TO 1100 CFM AT THIS BRANCH DUCT.

EXTEND 18X10 OA DUCT BACK TO

EXISTING AIR HANDLER; REBALANCE

OA TO 1100 CFM ON THIS BRANCH DUCT.

X

X

18X10

10X8

22X10

X

8X6

8X8 EG

100 CFM

8X8 EG

75 CFM

8X8 EG

75 CFM

8X8 EG

75 CFM

8X8 EG

75 CFM

8X8 EG

75 CFM

X

8X8 EG

75 CFM

TYP OF 2

X

8X4

8X8 EG

75 CFM

X

E G

C F

M

14X10

22X12

14X8

12X8

22X22 FRG

925 CFM

6X4

14X14 FRG

425 CFM

14X14 FRG

420 CFM

14X10

14X14 FRG

300 CFM

14X8

14X14 FRG

300 CFM

14X14 FRG

425 CFM

8X8 EG

75 CFM

14X10

14X14 FRG

425 CFM

14X10

14X14 FRG

425 CFM

14X14 FRG

325 CFM

14X8 14X10

14X14 FRG

420 CFM

16X16 FRG

555 CFM

14X14 FRG

360 CFM

14X14 FRG

190 CFM

14X10

14X14 FRG

6X4

14X14 FRG

425 CFM

14X10

14X14 FRG

425 CFM

10X6 SG

50 CFM

14X14 FRG

425 CFM

14X10

KEY PLAN

FCU-B

FCU-D

FCU-C

FCU-C

FCU-C

FCU-C

FCU-C

FCU-C

FCU-E

FCU-C

FCU-C

FCU-C

TOILET

HAC

STORAGE TOILET

TOILET TOILET TOILET

TOILETTOILET

TOILET

TOILET

TOILET

TOILET

TOILET

1 BED

1 BED

1 BED

1 BED

1 BED

1 BED

1 BED

CLOSET ELECTROMECH

NURSE STATION

MEDICINE

KITCHEN

TOILET

1 BED

1 BED

ANTE-

ROOM

ANTE-

ROOM

CORRIDOR

C O

R R

ID

O R

1 BED

1 BED

STAIR 3

STAIR 1

1 BED

1 BED

TOILET

SOILED UTL

CLEAN

STORAGE

NURSE

MDN

CONFERENCE

BREAK ROOM

LINEN &

EQUIPMENT

STORAGE

STORAGE

FCU-E

FCU-C

FCU-C

FCU-A

1 2

F.H.C.

STAIR 3

AC BA

C

BA

C

BA

C

C

C

BA

C

BA

C

A

Building Number

700 SOUTH 19th STREET 35233

VAMC-BIRMINGHAM, ALABAMALocation:Approved: Service Director

DEPARTMENT OF VETERANS AFFAIRS

MEDICAL CENTER

BIRMINGHAM,ALABAMA

Date

PROJECTS MANAGEMENT

ENGINEERING SERVICE (138)

SCALE:

DRAWING NAME PROJECT NAME: DATE:

DRAWING NUMBER:

FILE:

DRAWN BY:CHECKED BY:

PROJECT NUMBER:

524 West Peachtree St NW

Atlanta GA 30308 t 404 876 3800

Rosser International, Inc.

www.rosser.com

12345678

8 7 6 5 4 3 2 1

G

F

E

D

C

B

A

Revisions

DENTAL RENOVATION &

INCREASE MEDICINE BEDS

521-326

VA 248-C-0838

ROSSER 09076.00

H

G

F

E

D

C

B

A

H

01/06/2012

This drawing and all prints of it are the property of Rosser International, Inc. Prints are to be returned to Rosser International, Inc. upon completion of use for which they were issued.

Reproductions of these drawings without written consent of Rosser International, Inc. is not permitted and Rosser International, Inc. retains all common law, statutory and other reserved rights, including the copyright thereto.

This Record Document has been prepared, in part, based upon construction information furnished by others. While this information is believed to be reliable, Rosser International cannot assure its accuracy, and thus is not responsible for the accuracy of this Record

Document or for any errors or omissions which may have been incorporated into it as a result.AS-BUILT RECORD DRAWING 01/06/2012

A S -B

U

IL

T R

E C

O R

D D

R A

W

IN

G

A S -B

U

IL

T R

E C

O R

D D

R A

W

IN

G

AS-BUILT RECORD DRAWING

AS-BUILT RECORD DRAWING

M

M

N

N

EXISTING CHILLED WATER SUPPLY

EXISTING CHILLED WATER RETURN

EXISTING CHILLED WATER RETURN

EXISTING CHILLED WATER RETURN

EXISTING CHILLED WATER SUPPLY

EXISTING CHILLED WATER SUPPLY

EXISTING CONDENSATE DRAIN LINE

EXISTING CONDENSATE DRAIN LINE

EXISTING CONDENSATE DRAIN LINE

NOTES:

EXISTING STEAM AND CONDENSATE RETURN RISER1

1 1 1 1

6th FLOOR RENOVATION PLAN - HVAC PIPING M4.03

SCALE: �"=1’-0"

2 3

1" LP STEAM

�" CONDENSATE RETURN

621 623

ISOLATION

ISOLATION

PROVIDE AND INSTALL CONDENSATE PUMP. ROUTE�"

CONDENSATE LINE FROM DISCHARGE OF PUMP TO

MAIN CONDENSATION PIPE AS SHOWN.

NEW �" STEAM SUPPLY AND �" CONDENSATE RETURN TO NEW FAN COIL UNIT OR VAV BOX.

SLOPE CONDENSATE RETURN BACK TO RISER AT �" PER FOOT.

1 "

1 "

1 "

1" LP STEAM

�" CONDENSATE RETURN

PATIENT UNIT

6th FLOOR RENOVATION PLAN

HVAC PIPING

�"=1’-0" W. CURRY M4.03

M0403.DGN

KEY PLAN

FCU-B

FCU-D

FCU-C

FCU-C

FCU-C

FCU-C

FCU-C

FCU-C

FCU-C

FCU-A

FCU-C

FCU-E

FCU-C

FCU-C

FCU-C

TOILET

HAC

STORAGE

TOILET

TOILET

TOILET TOILET

TOILET

TOILET

TOILET

TOILET

TOILET

TOILET

TOILET

1 BED

1 BED

1 BED

1 BED

1 BED

1 BED

1 BED

CLOSET

ELECTROMECH

NURSE STATION

MEDICINE

KITCHEN

TOILET

1 BED

1 BED

ANTE-

ROOM

ANTE-

ROOM

CORRIDOR

C O

R R

ID

O R

1 BED

1 BED

STAIR 3

STAIR 1

1 BED

1 BED

TOILET

SOILED UTL

CLEAN

STORAGE

NURSE

MDN

BREAK ROOM

LINEN &

EQUIPMENT

STORAGE

STORAGE

CONFERENCE

FCU-E

700 SOUTH 19th STREET 35233

VAMC-BIRMINGHAM, ALABAMALocation:Approved: Service Director

DEPARTMENT OF VETERANS AFFAIRS

MEDICAL CENTER

BIRMINGHAM,ALABAMA

Date

PROJECTS MANAGEMENT

ENGINEERING SERVICE (138)

SCALE:

DRAWING NAME PROJECT NAME: DATE:

DRAWING NUMBER:

FILE:

DRAWN BY:CHECKED BY:

PROJECT NUMBER:

524 West Peachtree St NW

Atlanta GA 30308 t 404 876 3800

Rosser International, Inc.

www.rosser.com

12345678

8 7 6 5 4 3 2 1

G

F

E

D

C

B

A

Revisions

DENTAL RENOVATION &

INCREASE MEDICINE BEDS

521-326

VA 248-C-0838

ROSSER 09076.00

H

G

F

E

D

C

B

A

H

01/06/2012

This drawing and all prints of it are the property of Rosser International, Inc. Prints are to be returned to Rosser International, Inc. upon completion of use for which they were issued.

Reproductions of these drawings without written consent of Rosser International, Inc. is not permitted and Rosser International, Inc. retains all common law, statutory and other reserved rights, including the copyright thereto.

This Record Document has been prepared, in part, based upon construction information furnished by others. While this information is believed to be reliable, Rosser International cannot assure its accuracy, and thus is not responsible for the accuracy of this Record

Document or for any errors or omissions which may have been incorporated into it as a result.AS-BUILT RECORD DRAWING 01/06/2012

A S -B

U

IL

T R

E C

O R

D D

R A

W

IN

G

A S -B

U

IL

T R

E C

O R

D D

R A

W

IN

G

AS-BUILT RECORD DRAWING

AS-BUILT RECORD DRAWING

DETAILS

NONE W. CURRY M6.01

M0601.DGN

NTS

VARIABLE AIR VOLUME AIR HANDLING UNIT WITH MINIMUM OUTSIDE AIR CONTROL DIAGRAM

P R

IL

T E

R

OUTSIDE

AIR

D-1

C O

P R

E H

E A

T

C

O L

IN

G

LOCATE SENSOR

OUTSIDE UNDER

SHIELD

MPS

V-2

V-1

CHR

CHS

SUPPLY FAN

F

IN

A L

T E

R

A F

M D

SUPPLY AIR TO

TERMINAL UNIT

TT

TT

TT TT

HT

FT

D-4

A F

M D

MINIMUM

OUTSIDE

AIR

HS

CS

VFD

T-5

T-2

T-3 T-6

IT

SD

PRESSURE SWITCH HIGH

TO DISABLE FAN WHEN HIGH PRESSURE

LIMIT SETPOINT IS REACHED

PSH

SMOKE

DETECTOR

VARIABLE FREQUENCY

DRIVE, TYP.

DIFFUSER

SECTION

ZC

ZC

FT DPS

TT

T-1

SST

SPD

HHL

DPS

SD

SPS

TSL

TSL-1

UNIT IS NORMALLY STARTED AND STOPPED REMOTELY AT THE ECC. H-O-A SWITCH SHALL

BE KEPT IN THE "AUTO" POSITION. "HAND" AND "OFF" POSITIONS SHALL BE USED ONLY

FOR MAINTENANCE. WHEN THE UNIT IS "OFF" D-1, D-3, SHALL BE FULLY CLOSED. WHEN

THE UNIT IS "ON" D-1, SD-1 AND SD-2 SHALL BE FULLY OPEN. D-2 AND D-3 SHALL

MODULATE IN ACCORDANCE WITH THE FOLLOWING SEQUENCE:

6.

6.1

6.2

THE SUPPLY AIR FLOW SHALL BE CONTROLLED BY THE DIGITAL CONTROL PANEL

MODULATING THE SUPPLY FAN ADJUSTABLE SPEED MOTOR CONTROLLER TO MAINTAIN 1.0"

[25mm] OF DUCT STATIC PRESSURE (FIELD ADJUSTABLE), SENSED BY SPS-1. RESET

STATIC PRESSURE BASED ON ACTUAL BUILDING LOAD BY POLLING ALL ATU

THE DIGITAL CONTROL PANEL, USING TOTAL SUPPLY AIR AND RETURN AIR FLOW SIGNALS,

SHALL RESET THE RETURN AIR FAN ASD TO MAINTAIN A CONSTANT AIR FLOW DIFFERENCE

BETWEEN THE SUPPLY AIR AND THE RETURN AIR EQUAL TO MINIMUM OUTSIDE AIR.

USING HIGH PRESSURE SENSOR SPS-2 LOCATED AT THE SUPPLY FAN DISCHARGE, SHALL

PREVENT THE SUPPLY FAN FROM DEVELOPING OVER 3" [75mm] OF STATIC PRESSURE

(FIELD ADJUSTABLE). IF STATIC PRESSURE AT SPS-2 DOES EXCEED 3" [75mm] THE

SUPPLY AIR FAN SHALL STOP. SPS-2 SHALL BE HARDWIRED TO THE SUPPLY FAN UFD

AND UNIT SHALL BE SHUTDOWN IN HAND,AUTO OR BYPASS MODE. SPS-2 WILL REQUIRE

MANUAL RESET AT THE DEVICE.

UPON FAILURE OF THE VFD, THE SUPPLY AND RETURN FANS SHALL BE STARTED/STOPPED

MANUALLY AT THE DIGITAL CONTROL PANEL OR THE ECC THROUGH THE BY-PASS

STARTER. FANS SHALL THEN BE OPERATED AT CONSTANT SPEED.

IF THE AIR TEMPERATURE AS SENSED BY TT-3 FALLS BELOW 45°F [7°C], AN ALARM

SIGNAL SHALL INDICATE AT THE DCP AND ECC. IF THIS TEMPERATURE FALLS BELOW 40°F

[4.4°C], AS SENSED BY THE TSL THE SUPPLY AND RETURN FANS SHALL SHUT DOWN AND

A CRITICAL ALARM SHALL INDICATE AT THE DIGITAL CONTROL PANEL AND ECC. TSL SHALL

BE HARDWIRED TO THE SUPPLY FAN UFD AND UNIT SHALL BE SHUTDOWN IN HAND,AUTO

OR BYPASS MODE. TSL WILL REQUIRE MANUAL RESET AT THE DEVICE.

WHEN SMOKE IS DETECTED BY DUCT SMOKE DETECTOR, SD, THE SUPPLY AND RETURN

FANS SHALL SHUT "OFF" AND AN ALARM SIGNAL SHALL BE TRANSMITTED TO THE FIRE

ALARM SYSTEM. ALL SMOKE DAMPERS IN THE SUPPLY AND RETURN DUCTS SHALL CLOSE.

EXHAUST FANS SERVING AREA OF THE SUPPLY FAN SHALL CONTINUE TO RUN. SUPPLY

AND RETURN FANS SHALL RESTART AND SMOKE DAMPERS SHALL OPEN WHEN FIRE ALARM

CIRCUIT IS RESET.

ALARM

PROCESSING

D U

T Y

C

L E

F U

N C

T

IO

N

S C

H E

D U

L E

S

T A R

T

S T O

P

SUPPLY FAN VFD ALARM

STATIC PRESSURE HIGH LIMIT

Supply Air Flow (cfm)

RETURN LOW PRESSURE

S T A T U

S

SYSTEM

A L

A R

M

P R

IO

R

IT

Y

A D

D

A L T E R

N A

N

E L E

C T

IC

D

V

IC

E

S P

E

M M

A N

D

P O

IN

T

ID

Discharge Static Pressure

Discharge Air Humidity

Discharge Air Temperature

Pre-Heat Temperature

Mixed Air Temperature

Cooiling Coil Temperature

SYSTEM COMPONENT:

Return Air Flow (cfm)

Return air Temperature

O P

E N

C L

O S

E

S T A R

T

S T O

P

V A L

V E

P

O S

IT

IO

N

D A

M P

E R

P

O S

IT

IO

N

VAV AIR HANDLER

SYSTEM:

BUILDING:

LEGEND

POINT

BINARY

T E

M P

E R

A T U

R E

T I)

L o c a l

A la rm

P a n e l

M a s te r

A la rm

P a n e l

A re a la rm

P a n e l

H

IG

H

S

T A T

IC

P

R E S S

U R

E

H

IG

H

U

M

ID

IT

Y

P R

E S S

U R

E

L

W

M P

E R

A T U

R E

P E

R C

E N

T

P R

E S S

U R

E

P O

S

IT

IO

N F L

O W

H

IG

IM

IT

L

IT

SYSTEM INPUTS

ANA- BINARY ANALOG

S P

A

M P

C O

N T R

O L

S T A T

IC

P

R E S S

U

S

E T

D E

M A

IT

IN

G

T E

M P

E R

A T U

S

E T

T E

M P

E R

A T U

V E

R R

ID

E

E N

T H

A L P

O N

O M

IZ

E R

T E

M P

E R

A T U

O N

O M

IZ

E R

F A

IL

U

D E

P R E S S

U R E

V O

L U

N T R

O L

REMARKS

F U

M M

U N

IC

A T

IO

N

SYSTEM SOFTWARE/CONTROL

APPLICATION/FUNCTION

Return Air Humidity

SUPPLY FAN STATUS

MIXED AIR LOW LIMIT

RETURN AIR DAMPER

COILING VALVE V-1

PRE-HEAT VALVE V-2

SUPPLY FAN VFD

OUTSIDE AIR DAMPER

S T A T

IC

P

R E S S

U R

E

C A R

B

N O

X

ID

E

H U

M

ID

IT

Y V

A C

U U

M

STEAM ISOLATION VALVE V-3

SUPPLY FAN START/STOP

AI-1

AI-2

AI-3

AI-4

AI-5

AI-6

AI-7

AI-8

AI-9

AI-10

T R

E N

D

IN

G

OUTSIDE AIR TEMPERATURE AI-11

BI-1

BI-3

BI-4

BI-5

BI-7

AO-2

AO-3

AO-4

AO-8

AO-9

BO-2

BO-3

FULL COMMUNICATION

A B

B R

E V

IA

T

IO

N

RAT

RAH

RAF

MAT

PHT

CCT

DAT

DASP

DAH

SAF

OAT

RLP

SF-STS

TSL-1

SPS-2

SF-ALA

SF-SPD

OAD

RAD

PHT-V1

CLG-V1

SF-SST

HUM-ISO-V3

NTS

MINIMUM OUTSIDE AIR

POINTS LIST FOR VAV AIR HANDLING UNIT WITH

OUTPUTS

LOG

NTS

ROOM THERMOSTAT/SENSOR

WALL MOUNTED

48" [1200mm] AFF.

VARIABLE VOLUME AIR TERMINAL UNIT CONTROL DIAGRAM

RHC

HWS

HWR

V-1

REHEAT

COIL

AIR

TERMINAL

UNIT

AIR

FLOW

TE

ATU

CONTROLLER

PC

TE

IR

F M

HEATING

MINIMUM

SP

W/DEADBAND

100%

V

V

F L O

WR

E

H E

A T

F L O

W

A. SET POINTS SHALL BE SET AS FOLLOWS:

COOLING SET POINTS WILL BE MAINTAINED.

B. UPON FALL IN SPACE TEMPERATURE THE

VAV DAMPER WILL MODULATE TO MINIMUM

POSITION.

C. UPON FURTHER DROP IN SPACE

TEMPERATURE VALVE V-1 WILL MODULATE

TO MAINTAIN SET POINT

ADJUSTABLE TOLERANCE OF

BEEN SELECTED TO PREVENT VALVE

HUNTING

D. THE REVERSE SHALL OCCUR ON THE RISE

IN SPACE TEMPERATURE.

FE

M6.01

M6.01

M6.01

1.

1.1

SUPPLY AIR TEMPERATURE, SENSED BY TT-1, SHALL BE MAINTAINED AT SETPOINT VIA

DIGITAL CONTROL PANEL BY MODULATING V-1 OR D-2 AND D-3 OR V-2 IN SEQUENCE.

WHEN THE TEMPERATURE OF THE OUTSIDE AIR, SENSED BY TT-2, IS ABOVE 75°F (ADJ)

[23.8°C], THE DIGITAL CONTROL PANEL SHALL PREVENT THE MODULATION OF D-2 AND

D-3 AND SHALL ASSUME THE MINIMUM OUTSIDE AIR POSITION (D-2 FULLY OPENED AND

D-3 FULLY CLOSED). THE DIGITAL CONTROL PANEL SHALL MODULATE V-1 TO MAINTAIN

THE SUPPLY AIR TEMPERATURE, SENSED BY TT-1.

WHEN THE TEMPERATURE OF THE OUTSIDE AIR, SENSED BY TT-2, IS BETWEEN 65°F

[18.3°C] AND THE SUPPLY AIR TEMPERATURE SENSED BY TT-1, DAMPER D-2 SHALL

FULLY CLOSE AND D1 AND D3 SHALL BE FULLY OPEN (MAXIMUM OUTSIDE AIR POSITION).

THE DIGITAL CONTROL PANEL SHALL MODULATE V-1 TO MAINTAIN THE SUPPLY AIR

TEMPERATURE, SENSED BY TT-1.

WHEN THE TEMPERATURE OF THE OUTSIDE AIR, SENSED BY TT-2, IS BELOW THE SUPPLY

AIR TEMPERATURE, SENSED BY TT-1, DAMPERS D1, D-2 AND D-3 SHALL MODULATE TO

MAINTAIN THE SCHEDULED SUPPLY AIR TEMPERATURE. IF D-2 IS OPEN AND D-3 IS

CLOSED TO MINIMUM OUTSIDE AIR, V-2 SHALL MODULATE OPEN TO MAINTAIN THE SUPPLY

AIR TEMPERATURE, SENSED BY TT-1.

2.

2.1

2.2

2.3

2.4

3.

3.1

3.2

3.3

5.

5.1

7.

7.1

VAV

BIRMINGHAM MEDIAL CENTER-DENTAL AREAS

SEQUENCE OF OPERATION FOR VARIABLE AIR VOLUME AIR HANDLING UNIT WITH MINIMUM

OUTSIDE AIR

AUTOMATIC SHUTDOWN/RESTART

VAV BOX CONTROL SEQUENCE

GENERAL

TEMPERATURE CONTROL

AIR FLOW CONTROL

FREEZE PROTECTION

EMERGENCY CONSTANT SPEED OPERATION

700 SOUTH 19th STREET 35233

VAMC-BIRMINGHAM, ALABAMALocation:Approved: Service Director

DEPARTMENT OF VETERANS AFFAIRS

MEDICAL CENTER

BIRMINGHAM,ALABAMA

Date

PROJECTS MANAGEMENT

ENGINEERING SERVICE (138)

SCALE:

DRAWING NAME PROJECT NAME: DATE:

DRAWING NUMBER:

FILE:

DRAWN BY:CHECKED BY:

PROJECT NUMBER:

524 West Peachtree St NW

Atlanta GA 30308 t 404 876 3800

Rosser International, Inc.

www.rosser.com

12345678

8 7 6 5 4 3 2 1

G

F

E

D

C

B

A

Revisions

DENTAL RENOVATION &

INCREASE MEDICINE BEDS

521-326

VA 248-C-0838

ROSSER 09076.00

H

G

F

E

D

C

B

A

H

01/06/2012

This drawing and all prints of it are the property of Rosser International, Inc. Prints are to be returned to Rosser International, Inc. upon completion of use for which they were issued.

Reproductions of these drawings without written consent of Rosser International, Inc. is not permitted and Rosser International, Inc. retains all common law, statutory and other reserved rights, including the copyright thereto.

This Record Document has been prepared, in part, based upon construction information furnished by others. While this information is believed to be reliable, Rosser International cannot assure its accuracy, and thus is not responsible for the accuracy of this Record

Document or for any errors or omissions which may have been incorporated into it as a result.AS-BUILT RECORD DRAWING 01/06/2012

A S -B

U

IL

T R

E C

O R

D D

R A

W

IN

G

A S -B

U

IL

T R

E C

O R

D D

R A

W

IN

G

AS-BUILT RECORD DRAWING

AS-BUILT RECORD DRAWING

DETAILS

NONE W. CURRY M6.02

M0602.DGN

ASSEMBLY

NTS

FLOAT AND THERMOSTATIC STEAM TRAP

1. ALL DRIP POINTS ON STEAM MAINS SHALL BE PROVIDED WITH A 12" MINIMUM HIGH DRIP LEG

FROM BOTTOM OF STEAM MAIN TO TRAP INLET. DRIP LEG SHALL HAVE 6" SCALE POCKET

BELOW TRAP INLET.

TO RETURN MAIN

PIPE SIZE SHALL BE SAME SIZE

AS TRAP

FLOAT AND THERMOSTATIC

TRAP. SEE PLANS, AND

SCHEDULES

DIELECTRIC FITTING

WHERE RETURN IS

COPPER PIPE

FL

OW

SCHEDULE 80

STEEL PIPE

BYPASS-INSTALL IN HORIZONTAL

PLANE LEVEL WITH TRAP OR IN

VERTICAL PLANE & BELOW TRAP

PROVIDE BYPASS PIPING FOR ALL

TRAPS 1" AND LARGER.

IN

IN

DRIP LEG OR EQUIPMENT

CONNECTION. MAKE THE SAME

SIZE AS THE SUPPLY MAIN OR

EQUIPMENT CONNECTION. SEE

NOTE 1

m m m m

SCHEDULE 80 STEEL PIPE

SEE DRAWINGS FOR PIPE SIZES

1" GATE

VALVE

M6.02

5 FT

THRU [20]

6 8 10

[32][25] [40]

[65]

[50]

[75]

-1312 14 -16 -

[125][100]

[150]

[250]

[200]

[300]

[400]

[350]

[450]

[600]

[500]

20 241814 16128 1064 532 2 1/21 1/21 1 1/4

[9100][9600][8500][7600] [8200][7000][5800] [6700][5200][4100] [4900][3700][3000] [3400][2700][2100]

--- --[4900] -[4100][3700] [4000] -[3000][2400][1800][1500]

THRU 3/4

[2100] [2100]

[2100]

[2700]

[2400]

NTS

PROVIDE INSULATION SHIELD

& INSERT FOR ALL PIPING

(8" [200mm] MIN.)

BAND

1-5/8" [43mm] 12 GAUGE

CHANNEL OR 2"x2"x1/4"

[50x50x6.4mm] ANGLE

1/2" [15mm] DIA.

HANGER RODS WITH

36" [900mm] MAX.

SPACING ON EACH

CHANNEL

WELD

SADDLE

INSULATION SHIELD

AT HANGER

PROVIDE HIGH COMPRESSIVE

STRENGTH INSULATION (9

PSF MIN. DENSITY) UNDER

INSULATION SHIELD

INSULATION (VAPOR

BARRIER TYPE IS

REQUIRED FOR LOW

TEMPERATURE PIPE)

HANGER ROD

MAXIMUM PIPE/TUBING SUPPORT SPACING

NOTE: FOR TRAPEZE HANGER TAKE SPACING OF SMALLEST SIZE ON TRAPEZE.

NOM. SIZE

PIPE

TUBING

IN.

[mm]

FT.

[mm]

FT.

[mm]

PIPE HANGERS

m m

X

NOTES:

SEE SPECIFER FOR DETAILED

HANGER REQUIREMENTS

M6.02 NTS

ABOVE 2" [50mm] DIA. PIPE 2" [50mm] DIA. & SMALLER

ABOVE 2" [50mm] DIA. PIPE 2" [50mm] DIA. & SMALLER

INSTALLATION OF THERMOMETER WELLS

2 1/2" [65mm] DIA.

M6.02

AIR HANDLING UNIT DRAIN TRAP DETAIL

NTS

DRAW THRU

BLOW THRU

2" [50mm]

PLUS X

1" [25mm]

MINIMUM

X

2X

UNIT TYPE A B

WHERE X = STATIC PRESSURE IN PAN

DRAIN LINE SHALL BE AT LEAST THE SAME

SIZE AS THE NIPPLE ON THE DRAIN PAN

PIPING SHALL BE RIGID COPPER TYPE L OR

TYPE M UNLESS NOTE BELOW IS MET

PITCH DOWN

TOWARD DRAIN

CLEAN OUT

FLOOR SINK

DRAIN

PAN

1. CPVC PIPE MAY BE USED ONLY IF APPROVED BY

LOCAL VA AND IS INDOORS AND DOES NOT PASS THROUGH RATED

BARRIERS.

2. DIELECTRIC FITTING TO BE USED WHEN TWO DISSIMILAR METALS

ARE TO BE CONNECTED.

1355.2mA

1345.77mB m m

DIELECTRIC

FITTING

314.06m1"

M6.02

PIPING CONNECTIONS

NTS

COIL

TEST PLUG (TYP.)

REDUCER, IF REQUIRED

WATER RETURN

MANUAL AIR VENT

UNION CONNECTIONS

(TYP.)

WATER SUPPLY

TERMINAL UNIT WATER COILS -

SHUT OFF VALVE

DRAIN WITH HOSE

CONNECTION

MV

MODULATION CONTROL VALVE

M6.02

NOTE:

SIDE VIEW TRAPEZE HANGER FOR UP TO

1000 LB. [453KG] UNIFORM LOAD

ADJUSTABLE CLEVIS HANGER

TYPE 1 - SEE SPECIFICATIONS

ADJUSTABLE CLEVIS HANGER

TYPE 43 - SEE SPECIFICATIONS

VERTICAL

HORIZONTAL

NOTE:

700 SOUTH 19th STREET 35233

VAMC-BIRMINGHAM, ALABAMALocation:Approved: Service Director

DEPARTMENT OF VETERANS AFFAIRS

MEDICAL CENTER

BIRMINGHAM,ALABAMA

Date

PROJECTS MANAGEMENT

ENGINEERING SERVICE (138)

SCALE:

DRAWING NAME PROJECT NAME: DATE:

DRAWING NUMBER:

FILE:

DRAWN BY:CHECKED BY:

PROJECT NUMBER:

524 West Peachtree St NW

Atlanta GA 30308 t 404 876 3800

Rosser International, Inc.

www.rosser.com

12345678

8 7 6 5 4 3 2 1

G

F

E

D

C

B

A

Revisions

DENTAL RENOVATION &

INCREASE MEDICINE BEDS

521-326

VA 248-C-0838

ROSSER 09076.00

H

G

F

E

D

C

B

A

H

01/06/2012

This drawing and all prints of it are the property of Rosser International, Inc. Prints are to be returned to Rosser International, Inc. upon completion of use for which they were issued.

Reproductions of these drawings without written consent of Rosser International, Inc. is not permitted and Rosser International, Inc. retains all common law, statutory and other reserved rights, including the copyright thereto.

This Record Document has been prepared, in part, based upon construction information furnished by others. While this information is believed to be reliable, Rosser International cannot assure its accuracy, and thus is not responsible for the accuracy of this Record

Document or for any errors or omissions which may have been incorporated into it as a result.AS-BUILT RECORD DRAWING 01/06/2012

A S -B

U

IL

T R

E C

O R

D D

R A

W

IN

G

A S -B

U

IL

T R

E C

O R

D D

R A

W

IN

G

AS-BUILT RECORD DRAWING

AS-BUILT RECORD DRAWING

DETAILS

NONE W. CURRY M6.03

M0603.DGN

NTS

DUCTWORK SQUARE VANE ELBOWS

1.

2.

3.

4.

ALL VANE ELBOWS SHALL BE CONSTRUCTED AND INSTALLED AS DETAILED BY

SMACNA.

WHEN W1 DOES NOT EQUAL W2, VANE SHALL BE SINGLE THICKNESS VANE TYPE

REGARDLESS OF W DIMENSION.

ALL SINGLE THICKNESS VANES SHALL HAVE A 2" [50mm] RADIUS, 1 1/2"

[40mm] MAXIMUM SPACE BETWEEN VANES AND A 3/4" [20mm] TRAILING EDGE.

WHEN W EQUALS W2 AND W1 IS GREATER THAN 20" [500mm] VANES SHALL BE

DOUBLE VANE TYPE.

1707.51mW2

1765.32mW1

M6.03

NTS

DUCTWORK RADIUS ELBOWS

VANE

VANE

1.

2.

THE INTERIOR SURFACE OF ALL RADIUS ELBOWS SHALL BE MADE ROUND.

ALL STANDARD RADIUS ELBOWS CAN BE SUBSTITUTED WITH SHORT RADIUS

ELBOWS. ALL SHORT RADIUS ELBOWS SHALL HAVE VANES. VANES SHALL BE

CONSTRUCTED, SUPPORTED AND FASTENED AS RECOMMENDED BY SMACNA.

R SHALL

EQUAL OR

BE

GREATER

THAN W.

R SHALL

EQUAL OR

BE

GREATER

THAN

1/3W.

1006.87mW

957.31mR R

973.02m2/3W

487.07m1/3W

R SHALL

EQUAL OR

BE

GREATER

THAN

1/6W.

1499.49m W 1684.43m W

996.86m1/2W

502.24m1/3W

235.36m 1/6W

R

M6.03

NTS

SUPPLY DUCTWORK TAKE-OFFS

AIR

FLOW

AIR

FLOW

O W

965.61m

SUPPLY REGISTER

OR BRANCH DUCT

TURNING VANES

MAIN

SUPPLY

DUCT

SEE FLOOR PLAN FOR

SPLIT DIMENSION

PROVIDE VOLUME

DAMPER

PROVIDE VOLUME

DAMPER

ADJUSTABLE

METAL ROD

OR LINKAGE

TOP REGISTER

MAIN

SUPPLY

DUCT

VOLUME EXTRACTOR; ADJUSTABLE

FROM FULLY CLOSED POSITION TO

CFM NOTED ON FLOOR PLANS

AIR

FLOW

AIR

FLOW

455.98m

1/4 W OR 4"

[100mm] MIN.

AIR

FLOW

MAIN SUPPLY

DUCT

914.38m W

O W

M6.03

NTS

EXHAUST OR RETURN BRANCH DUCTWORK

MAIN EXHAUST OR RETURNAIR

FLOW AIR

FLOW

498.8m

1052.15mW

PROVIDE VOLUME DAMPER

AT EACH BRANCH DUCT

1/4W OR 4"

[100mm] MIN.

BRANCH DUCT

VD

M6.03

NTS

VOLUME DAMPER DETAIL

1.

2.

DELETE INSULATION STAND-OFF ON DUCTWORK WITHOUT EXTERIOR INSULATION.

DETAIL SHOWS SINGLE BLADE DAMPER. DAMPER INSTALLATION SHALL BE SIMILAR

FOR MULTI-BLADE DAMPERS & ROUND DAMPERS.

INSULATION SEE

SPECIFICATION

DAMPER BLADE

1/8" [6mm]

CLEARANCE

ALL AROUND

OUTSIDE END BEARING

INSIDE END BEARING

HANDLE WITH

LOCKING

QUADRANT

INSULATION

STAND-OFF

1/2" [15mm] ROUND

ROD PIN

DUCT

STIFFEN BLADE

AS REQUIRED

M6.03

"B" "B"

ACCESS PANEL AND DOOR DETAIL

NTS

1. LATCHES SHALL BE OF THE WEDGE TYPE TO CLOSE DOORS

TIGHTLY.

2. HINGES ON THE ACCESS DOORS SHALL HAVE NON-CORROSIVE

PINS.

3. SEE SMACNA 2005, FIGURE 9-15

CASING

GASKET

HANDLE INSIDE

FLEXIBLE

WASHER

FACTORY

FABRICATED

LATCH

INSULATION

DUCT

GASKET

INSULATION

INSULATION

"A"

"A"

M6.03

NTS

ACCESS SECTION FOR ROUND/OVAL DUCT

HOUSING WELDED

TO DUCT SECTION

ROUND OR

FLAT OVAL

DUCT SECTION

COVER WITH HANDLE

AND CHAIN RETAINER

GASKETED AND

PRESSURE SEALED

M6.03

NTS

FLEXIBLE DUCT CONNECTIONS

FLANGED CONNECTION

ON FAN SIDE

WASHER 1-1/2" [40mm] MIN. TO 3" [75mm]

MAX. INSTALLED. 6" [150mm]

NOMINAL WITH MATERIAL TAUT

FLEXIBLE

MATERIAL AS

SPECIFIED

1"x1/8" [25x3mm] DRAW BAND

1"x1/8" [25x3mm] BAND IRON

BOLT ON 4" [100mm] CENTERS

5/16" [8mm] FLANGE

DUCT

SHEET METAL SCREWS ON

12" [300mm] CENTERS

RIVET ON 4"

[100mm]

CENTERS

SHEET METAL AS

SPECIFIED FOR

DUCTWORK.

1"x1/8" [25x3mm] BAND IRON

BOLT ON 4" [100mm] CENTERS

1" [25mm] FLANGE & HEMALTERNATE

POSITION

OF BOLT 1 1/2" [40mm]

POCKET SLIP

DUCT

SHEET METAL AS

SPECIFIED FOR

DUCTWORK.

536.45m 1/2"

[15mm] 536.45m 1/2"

[15mm] 1609.34m 1609.34m1 1/2"

[40mm]

1 1/2" [40mm] MIN. TO 3" [75mm]

MAX. INSTALLED. 6" [150mm]

NOMINAL WITH MATERIAL TAUT

4506.16m

FLANGED

CONNECTION

ON FAN SIDE

WASHER

FLEXIBLE MATERIAL

AS SPECIFIED

M6.03

NTS

FIRE DAMPER INSTALLATION

SECTION THRU

SLEEVE, NOTE 2

DUCT

CONNECTION

NOTE 4

DAMPER,

NOTE 1

DAMPER COLLAR

EXTENSION INTEGRAL

PART OF SLEEVE

SLEEVE, NOTE 2

NOTE 6FIRE BARRIER

PARTITION OR CHASE

TYPICAL DUCT

INSULATION

PERIMETER ANGLE, NOTE 3

(NOTE FASTENED TO PARTITION)

ACCESS

PANEL

NOTE 5

423.52m 1" m m

A VERTICAL DAMPER IS SHOWN. HORIZONTAL DAMPER INSTALLATION, 1S SIMILAR.

FOLLOW DAMPER MANUFACTURER’S INSTRUCTIONS, INCLUDING FASTENER OPTIONS AND

GAGES FOR SLEEVE AND PERIMETER ANGLES. FIRE DAMPERS MUST BE INSTALLED IN

THE PARTITION OR FLOOR AND NOT OUTSIDE THE PENETRATION.

GALVANIZED SLEEVE: GAGE NOT LESS THAN CONNECTING DUCT. FASTEN SLEEVE TO

DAMPER FRAME AND TO PERIMETER ANGLES.

PERIMETER ANGELS: GALVANIZED STEEL, NOT LESS THAN 1 1/2"x1 1/2" [40x40mm], 14 GAGE, TO PROVIDE 1" [25mm] MINIMUM OVERLAP OF OPENING ON ALL 4 SIDES.

BREAKAWAY DUCT CONNECTION: CONTRACTOR’S OPTION OF TYPES SHOWN IN SMACNA.

ACCESS PANELS: SIZE AND LOCATION TO PERMIT SERVICING THE FUSIBLE LINK OR

LINKS.

PROVIDE 1/4" TO 1/2" [6 TO 15mm] CLEARANCE ON HEIGHT AND WIDTH. FILL OPEN

SPACE WITH ROCK WOOL FIRESTOP FIBER.

ALL DUCT WORK RISERS WHICH ARE RUN EXPOSED, SUCH AS THRU ATTIC FLOORS

AND MECHANICAL ROOM FLOORS, SHALL BE PROVIDED WITH 3" [75mm] HIGH

CONCRETE CURB AROUND OPENING FOR DUCT.

1.

2.

3.

4.

5.

6.

M6.03

NTS

ROUND DUCT HANGERS

2500 [1133]

1320 [598]

420 [190]ONE 1 [25] x 18 GA STRAP36 [900]

ONE 1 [25] x 16 GA STRAP

84 [2100]

60 [1500]

50 [1250] 700 [317]

ONE 1 [25] x 22 GA STRAP

QUANTITY/SIZE

26 [650]

HANGER STRAPS OR RODS

MAX. LOAD

LBS. [kg]

260 [119]

MAX.

144 [3600]

IN. [mm]

SPACING

IN. [mm] IN. [mm]

144 [3600]

144 [3600]

144 [3600]

144 [3600]

TABULATED DATA FROM SMACNA

ALLOWS FOR DUCT REINFORCING AND

INSULATION, BUT NO EXTERNAL LOAD.

BAND

OVER 50"

HANGER RODS

BAND OF SAME

SIZE AS HANGER

STRAP

LOAD RATED

FASTENERS

50"

UNDER

DESCRIBE OR DETAIL UPPER ATTACHMENTS APPLICABLE TO PARTICULAR

PROJECTS.

M6.03

NTS

DUCT CONNECTIONS - AIR TERMINAL UNITS

1.

2.

3.

4.

5.

6.

RIGID STRAIGHT TERMINAL UNIT INLET LENGTH SHALL BE A

MINIMUM OF 3 TIMES THE DIAMETER OF INLET

A FLEXIBLE AIR DUCT CONNECTOR IS NOT MANDATORY FOR INLET TO

THIS BOX, BUT ALLOWED TO ACCOMMODATE MINOR OFFSETS. MAXIMUM

LENGTH 3’-0" [900mm].

A BRANCH DUCT SERVING AN INDIVIDUAL BOX MAY BE THE SAME SIZE

AS THE BOX INLET, PROVIDED THE EQUIVALENT LENGTH OF THE

BRANCH DUCT, AS SHOWN, DOES NOT EXCEED 10 FEET (3 METERS).

FOR LONGER LENGTHS, INCREASE THE DUCT SIZE AND PROVIDE A

DUCT TRANSITION TO MAINTAIN THE DUCT STATIC PRESSURE DROP AT

OR BELOW 0.2"/100’ [1.64Pa/m].

FLEXIBLE AIR DUCT CONNECTORS, WHEN USED FROM TERMINAL UNIT

SUPPLY AIR DUCT TO DIFFUSER, SHALL NOT EXCEED 5’-0" [1500mm].

COMPONENT ARRANGEMENT MAY VARY BY MANUFACTURER. PROVIDE

INSULATION W/VAPOR BARRIER FOR CONNECTING DUCT SECTIONS.

USE OF THE FLEXIBLE AIR DUCT CONNECTORS ARE NOT PERMITTED

FOR THE DEDICATED AHU SERVING THE SURGICAL SUITE.

AIR TERMINAL UNIT

(CV OR VAV)

REHEAT COIL

FLEXIBLE AIR DUCT

CONNECTOR. SEE DETAIL

DIFFUSER (TYP.)

SEE SPECIFICATIONS FOR

CLAMPS AND SEALANT (TYP.)

SEE NOTE 5

2628.6mSEE NOTE 4

4571.09mSEE NOTE 3

914.95mSEE NOTE 2

1460.29mSEE NOTE 1

SEE NOTE 1

SEE NOTE 2

SEE NOTE 3

S

M6.03

NOTE:

NOTE:

STANDARD RADIUS OR

LONG RADIUS ELBOW

SHORT RADIUS ELBOW

WITH ONE VANE

SHORT RADIUS ELBOW

WITH TWO VANES

AIR SPLIT DUCT TAKE-OFF

PLAN VIEW

BRANCH DUCT TAKE-OFF PLAN VIEW

SUPPLY REGISTER TAKE-OFF

PLAN VIEW

PLAN VIEW

NOTE:

SIDE ELEVATION SECTION

SECTION "A-A"

NOTES:

ACCESS PANEL

ACCESS DOOR SECTION "B-B"

ROUND FLEXIBLE CONNECTION

RECTANGULAR FLEXIBLE CONNECTION

NOTE:

NOTE:

DESIGNER’S NOTE:

700 SOUTH 19th STREET 35233

VAMC-BIRMINGHAM, ALABAMALocation:Approved: Service Director

DEPARTMENT OF VETERANS AFFAIRS

MEDICAL CENTER

BIRMINGHAM,ALABAMA

Date

PROJECTS MANAGEMENT

ENGINEERING SERVICE (138)

SCALE:

DRAWING NAME PROJECT NAME: DATE:

DRAWING NUMBER:

FILE:

DRAWN BY:CHECKED BY:

PROJECT NUMBER:

524 West Peachtree St NW

Atlanta GA 30308 t 404 876 3800

Rosser International, Inc.

www.rosser.com

12345678

8 7 6 5 4 3 2 1

G

F

E

D

C

B

A

Revisions

DENTAL RENOVATION &

INCREASE MEDICINE BEDS

521-326

VA 248-C-0838

ROSSER 09076.00

H

G

F

E

D

C

B

A

H

01/06/2012

This drawing and all prints of it are the property of Rosser International, Inc. Prints are to be returned to Rosser International, Inc. upon completion of use for which they were issued.

Reproductions of these drawings without written consent of Rosser International, Inc. is not permitted and Rosser International, Inc. retains all common law, statutory and other reserved rights, including the copyright thereto.

This Record Document has been prepared, in part, based upon construction information furnished by others. While this information is believed to be reliable, Rosser International cannot assure its accuracy, and thus is not responsible for the accuracy of this Record

Document or for any errors or omissions which may have been incorporated into it as a result.AS-BUILT RECORD DRAWING 01/06/2012

A S -B

U

IL

T R

E C

O R

D D

R A

W

IN

G

A S -B

U

IL

T R

E C

O R

D D

R A

W

IN

G

AS-BUILT RECORD DRAWING

AS-BUILT RECORD DRAWING

DETAILS

NONE W. CURRY M6.04

M0604.DGN

WATER COILS - PIPING CONNECTIONS1

NTS

WATER COIL

AIR VENT

WHEN COIL

IS NOT

SELF-VENTING

DRAIN WHEN COIL IS

NOT SELF-DRAINING

TEST PLUG

(TYP.)

PIPE HANGER SHALL SUPPORT

PIPING INDEPENDENT OF COIL

REDUCER, IF REQUIRED

DRAIN

WATER COIL

AIR VENT

WHEN COIL

IS NOT

SELF-VENTING

TEST PLUG

(TYP.)

PIPE HANGER SHALL SUPPORT

PIPING INDEPENDENT OF COIL

WATER COIL

REDUCER, IF REQUIRED

FLOW ELEMENT

DRAIN WHEN COIL IS

NOT SELF-DRAINING

DRAIN

1.

2.

3.

WHEN COIL IS INCLUDED IN CASING MOUNTED ON VIBRATION ISOLATORS THE FIRST

2 HANGERS FOR EACH PIPE SHALL BE SPRING & NEOPRENE TYPE. TYPE "H" FOR

PIPING SHALL BE INSTALLED IN SUCH MANNER THAT IT WILL NOT BLOCK THE

SWING OR USE OF ACCESS DOORS OR PANELS; NEITHER SHALL IT BLOCK THE

SERVICING OF FILTERS, VALES, OR EQUIPMENT.

THE FLOW ELEMENT MAY BE INSTALLED IN THE SUPPLY PIPING IF THE REQUIRED

MINIMUM UPSTREAM AND DOWNSTREAM DIMENSIONS CANNOT BE OBTAINED IN THE

RETURN PIPING.

FE

MV

MV

MV

MV

MVMV

FE

TI

TI

TEMPERATURE

INDICATION TO ECC

SEE CONTROL

DIAGRAM

MV

STEAM COIL - PIPING CONNECTIONS

NTS

1.

2.

3.

4.

5.

WHEN COIL IS INCLUDED IN CASING MOUNTED ON

VIBRATION ISOLATOR UNITS, THE RUNOUT PIPING FOR

CONNECTIONS TO COIL SHALL BE INSTALLED WITH

SWING JOINTS TO ALLOW FOR THE VIBRATION.

PIPING SHALL BE INSTALLED IN SUCH MANNER THAT

IT WILL NOT BLOCK THE SWING OR USE OF ACCESS

DOORS OR PANELS; NEITHER SHALL IT BLOCK THE

SERVICING OF FILTERS, VALVES, OR EQUIPMENT.

TRAP EACH COIL SEPARATELY WHEN INSTALLED IN A

BANK OF TWO OR MORE HIGH. ALSO PROVIDE

SEPARATE VACUUM BREAKER FOR EACH COIL.

TWO TRAP ASSEMBLIES IN PARALLEL ARE SHOWN.

TWO TRAPS REQUIRED WHEN CONDENSATE LOAD IS

5,000 LBS/HR [2400 KG/HR] OR GREATER.

SUPPLY & RETURN PIPES ARE SHOWN FROM SAME

END. REHEAT COIL MAY HAVE SUPPLY & RETURN

PIPES FROM OPPOSITE ENDS.

PIPE HANGER SHALL

SUPPORT PIPING

INDEPENDENT OF COIL

(TYP.)

PITCH COIL DOWN

1/4" [8mm] PER

FOOT TO

CONDENSATE

OUTLET

FULL SIZE

TAPPING

PRESSURE

GAGE

SCALE POCKET

SEE NOTE

NO. 4

STEAM CONDENSATE

RETURN

1/ 2" [15 mm] C

HE

CK

VAL

VE

VAC

UUM

BR

EAK

ER

INCREASER, IF

REQUIRED

REDUCER,

IF REQUIRED

M

IN

m m ]1

M

IN

m m

STEAM SUPPLY

NTS

1.

2.

3.

SECURE CURB CAP TO WOOD NAILING STRIP WITH 3/8" [10mm] CADMIUM PLATED

LAG BOLTS NOT OVER 12" [300mm] ON CENTER.

SECURE ROOF CURB, DUCTWORK AND DAMPER TO ROOF WITH EXPANSION BOLTS

(CONCRETE ROOF) OR RUST RESISTANT BOLTS (METAL DECK AND BAR JOIST

ROOF).

RUN ELECTRICAL LINES THROUGH CLEARANCE HOLE PROVIDED IN GRAVITY DAMPER,

THEN THROUGH VENTILATOR ELECTRICAL CONDUIT GUIDE.

POWER ROOF VENTILATOR

GRAVITY BACKDRAFT DAMPER

RIGID CONDUIT TO

ACCOMMODATE

ELECTRICAL WIRES

SEE NOTE 2

PREFABRICATED

ROOF CURB

WOOD NAILING

STRIP

ELECTRICAL

CONDUIT GUIDE

MOTOR HOUSING

DUCT

TRANSITION DUCT TO

FULL SIZE OF DAMPER

SUPPLIED WITH ROOF

VENTILATOR

ROOF

SEE NOTE 2

SEE NOTE 1

CURB CAP

CORRIDOR

ANTE ROOM

PATIENT ROOM

TOILET ROOM

ROOF

EXHAUST

BLOWER

HEPA FILTER

WITH

GRADE A

PREFILTER

T1

V1 m m

NTS

NEGATIVE ISOLATION ROOM

AIR SYSTEM FOR

dPS

ECC

HS

ITS/A

CV

TERMINAL

UNIT

W/REHEAT

EXHAUST

1.

2.

THE PATIENT BEDROOM IS KEPT UNDER NEGATIVE PRESSURE BY ENSURING AIR MOVEMENT INTO

THE BEDROOM SPACE FROM THE ANTE ROOM AND ADJOINING CORRIDOR.

THE SUPPLY AIR SYSTEM SHALL CONSIST OF THE CONSTANT VOLUME AIR DELIVERY FROM A

DEDICATED AIR TERMINAL UNIT WITH REHEAT COIL (OR A DUCT MOUNTED REHEAT COIL) TO THE

ISOLATION SUITE AS FOLLOWS:

A - PATIENT BEDROOM

B - ANTE ROOM

C - PATIENT TOILET

MINIMUM 12 ACPH SUPPLY AIR (ASHRAE 2007 HANDBOOK OF

APPLICATIONS). INCREASE SUPPLY AIR VOLUME, IF REQUIRED, TO

MEET THE INSIDE DESIGN CONDITIONS IN COOLING AND/OR HEATING

MODES. EXAMPLE: 400 CFM

MINIMUM 10 ACPH SUPPLY AIR (ASHRAE 2007 HANDBOOK OF

APPLICATIONS) OR MINIMUM 100 CFM. EXAMPLE: 100 CFM

DO NOT SUPPLY AIR INTO THE TOILET. DRAW MAKE-UP AIR FROM

THE PATIENT’S BEDROOM AND EXHAUST AT THE RATE OF 10 ACPH

OR 60 CFM. EXAMPLE: 60 CFM

THE DEDICATED EXHAUST AIR SYSTEM SHALL BE BALANCED AS FOLLOWS:

A - PATIENT BEDROOM

3.

3287.85m10’-0" MIN

M6.04

M6.04

M6.04

M6.04

T1

LEGEND

V1

ROOM THERMOSTAT TO CONTROL

COOLING AND HEATING, INCLUDING

PERIMETER HEAT (IF ANY)

AIR FLOW CONTROL VALVES

PRESSURE INDEPENDENT TYPE

400 CFM (SUPPLY) - 75 CFM (TOILET) + 75 CFM (ANTE ROOM)

+ 10% =440 CFM (EXHAUST)

NEW EXISTING

SINGLE COIL

DOUBLE COIL

NOTE:

NOTE:

TYPICAL AIR BALANCE EXAMPLE:

700 SOUTH 19th STREET 35233

VAMC-BIRMINGHAM, ALABAMALocation:Approved: Service Director

DEPARTMENT OF VETERANS AFFAIRS

MEDICAL CENTER

BIRMINGHAM,ALABAMA

Date

PROJECTS MANAGEMENT

ENGINEERING SERVICE (138)

SCALE:

DRAWING NAME PROJECT NAME: DATE:

DRAWING NUMBER:

FILE:

DRAWN…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .