08 71 00.docx

DOCX document 83 KB Posted

Attached to
Y1DZ--659-22-405 | Install Campus Generator | Salisbury VAMC
Solicitation number
36C24626B0011
Issued by

About this file

This is a specification document for door hardware and related installation requirements for a federal construction project. The specification establishes comprehensive standards for all door hardware components, including hinges, locks, closers, exit devices, thresholds, and accessory items required for complete door installation and operation at the W.G. (Bill) Hefner Department of Veterans Affairs Medical Center in Salisbury, North Carolina (Project 659-22-405).

The specification mandates compliance with multiple standards including ABAAS (Architectural Barriers Act Accessibility Standards), NFPA 80 and 101 for fire-rated doors, ANSI/BHMA standards for specific hardware types, and UL listing requirements. All hardware must be from the same manufacturer for mortise locksets, hinges, and overhead door closers. Hardware sets are organized by door type and function, with seven specific hardware sets detailed for various applications: exterior electrified general purpose doors, fuel yard doors, generator room doors, MEP rooms, and fire-rated assemblies. Key performance requirements include door opening force not exceeding 22.2 N (5 pounds) per ADA standards, adjustable closing force on closers, 7-pin removable core cylinders keyed to a Grand Master Key System, and specific installation heights for hardware (e.g., locksets and exit devices at 1024 mm from finished floor). Warranty periods vary by component, with locks and latches requiring 5 years, door closers and continuous hinges requiring 10 years, and automatic door operators requiring 2 years. The contractor must conduct a preinstallation meeting at least 30 days before hardware installation and provide maintenance manuals, installation instructions, certificates of compliance, and test reports. All hardware must be delivered in original containers with necessary appurtenances, and a final inspection with demonstration of mechanical and electrical systems is required upon completion.

View the file

Other files

File Type Posted
36C24626B0011 0003.docx DOCX document
01 91 00 VA Mark up.docx DOCX document
659-22-405 M-801-Blt 2.pdf PDF
RFIs_Response_Rev2.docx DOCX document
36C24626B0011 0002.docx DOCX document
01 32 16.15 - PROJECT SCHEDULES - Small Projects – DesignBidBuild.docx DOCX document
659-22-405_Install Campus Generator_Site Visit Sign In Sheet_03.17.2026.docx.pdf PDF
01 33 23 - SHOP DRAWINGS PRODUCT DATA SAMPLES.docx DOCX document
36C24626B0011 0001.docx DOCX document
01 91 00 - VA Mark-up.docx DOCX document
01 91 00 - GEN_COMMISSIONING REQUIR.docx DOCX document
01 45 00 - QUALITY CONTROL.docx DOCX document
36C24626B0011_2_Solicitation.docx DOCX document
659-22-405_Bid Set Specifications_Rev 1_.docx DOCX document
657-22-405 Salisbury Emergency Generator Bid Set_.pdf PDF
Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

03-01-24

SECTION 08 71 00

DOOR HARDWARE

GENERAL

DESCRIPTION

Door hardware and related items necessary for complete installation and operation of doors.

RELATED WORK

Caulking: Section 07 92 00 JOINT SEALANTS.

Application of Hardware: Section 08 11 13, HOLLOW METAL DOORS AND FRAMES Section 08 71 13, AUTOMATIC DOOR OPERATORS Section 08 71 13.11, LOW ENERGY DOOR OPERATORS Finishes: Section 09 06 00, SCHEDULE FOR FINISHES.

Painting: Section 09 91 00, PAINTING.

Card Readers: Section 28 13 00, PHYSICAL ACCESS CONTROL SYSTEMS.

Electrical: Division 26, ELECTRICAL.

Fire Detection: Section 28 31 00, FIRE DETECTION AND ALARM.

GENERAL

All hardware shall comply with ABAAS, (Architectural Barriers Act Accessibility Standard) unless specified otherwise.

Provide rated door hardware assemblies where required by most current version of the International Building Code (IBC).

Hardware for Labeled Fire Doors and Exit Doors: Conform to requirements of NFPA 80 for labeled fire doors and to NFPA 101 for exit doors, as well as to other requirements specified. Provide hardware listed by UL, except where heavier materials, large size, or better grades are specified herein under paragraph HARDWARE SETS. In lieu of UL labeling and listing, test reports from a nationally recognized testing agency may be submitted showing that hardware has been tested in accordance with UL test methods and that it conforms to NFPA requirements.

Hardware for application on metal doors and frames shall be made to standard templates. Furnish templates to the fabricator of these items in sufficient time so as not to delay the construction.

The following items shall be of the same manufacturer, except as otherwise specified:

Mortise locksets.

Hinges for hollow metal and wood doors.

Surface applied overhead door closers.

Exit devices.

Floor closers.

WARRANTY

Automatic door operators shall be subject to the terms of FAR Clause 52.246-21, except that the Warranty period shall be two years in lieu of one year for all items except as noted below:

Locks, latchsets, and panic hardware: 5 years.

Door closers and continuous hinges: 10 years.

MAINTENANCE MANUALS

In accordance with Section 01 00 00, GENERAL REQUIREMENTS Article titled "INSTRUCTIONS", furnish maintenance manuals and instructions on all door hardware. Provide installation instructions with the submittal documentation.

SUBMITTALS

Submittals shall be in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. Submit 6 copies of the schedule per Section 01 33 23. Submit 2 final copies of the final approved schedules to VAMC Locksmith as record copies (VISN Locksmith if the VAMC does not have a locksmith).

Hardware Schedule: AHC certified hardware consultant to prepare and submit hardware schedule in the following form:

Hardware Item
Quantity
Size
Reference Publication Type No.
Finish
Mfr. Name and Catalog No.
Key Control Symbols
UL Mark (if fire rated and listed)
ANSI/BHMA Finish Designation

Samples and Manufacturers' Literature:

Samples: All hardware items (proposed for the project) that have not been previously approved by Builders Hardware Manufacturers Association shall be submitted for approval. Tag and mark all items with manufacturer's name, catalog number and project number.

Samples are not required for hardware listed in the specifications by manufacturer's catalog number, if the contractor proposes to use the manufacturer's product specified.

Certificate of Compliance and Test Reports: Submit certificates that hardware conforms to the requirements specified herein. Certificates shall be accompanied by copies of reports as referenced. The testing shall have been conducted either in the manufacturer's plant and certified by an independent testing laboratory or conducted in an independent laboratory, within four years of submittal of reports for approval.

Record of opening force measurement for all doors equipped with closers

DELIVERY AND MARKING

Deliver items of hardware to job site in their original containers, complete with necessary appurtenances including screws, keys, and instructions. Tag one of each different item of hardware and deliver to COR for reference purposes. Tag shall identify items by Project Specification number and manufacturer's catalog number. These items shall remain on file in COR's office until all other similar items have been installed in project, at which time the COR will deliver items on file to Contractor for installation in predetermined locations on the project.

preinstallation meeting Convene a preinstallation meeting not less than 30 days before start of installation of door hardware. Require attendance of parties directly affecting work of this section, including Contractor and Installer, Architect, Project Engineer and VA Locksmith, Hardware Consultant, and Hardware Manufacturer’s Representative. Review the following:

Inspection of door hardware.

Job and surface readiness.

Coordination with other work.

Protection of hardware surfaces.

Substrate surface protection.

Installation.

Adjusting.

Repair.

Field quality control.

Cleaning.

INSTRUCTIONS

Hardware Set Symbols on Drawings: Except for protective plates, door stops, mutes, thresholds and the like specified herein, hardware requirements for each door are indicated on drawings by symbols. Symbols for hardware sets consist of letters (e.g., "HW") followed by a number. Each number designates a set of hardware items applicable to a door type.

Keying: All cylinders shall be keyed into existing Grand Master Key System. Provide removable core cylinders that are removable only with a special key or tool without disassembly of knob or lockset. Cylinders shall be 7 pin type. Keying information shall be furnished at a later date by the COR.

APPLICABLE PUBLICATIONS

The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by the basic designation only. In text, hardware items are referred to by series, types, etc., listed in such specifications and standards, except as otherwise specified.

ASTM International(ASTM):

F883-13 Padlocks E2180-18................Standard Test Method for Determining the Activity of Incorporated Antimicrobial Agent(s) In Polymeric or Hydrophobic Materials American National Standards Institute/Builders Hardware Manufacturers Association (ANSI/BHMA):

A156.1-06Butts and Hinges
A156.2-03Bored and Pre-assembled Locks and Latches
A156.3-08Exit Devices, Coordinators, and Auto Flush Bolts
A156.4-08Door Controls (Closers)
A156.5-14Cylinders and Input Devices for Locks.
A156.6-05Architectural Door Trim
A156.8-05Door Controls-Overhead Stops and Holders
A156.11-14Cabinet Locks

A156.12-05 .............Interconnected Locks and Latches A156.13-05 Mortise Locks and Latches Series 1000 A156.14-07 .............Sliding and Folding Door Hardware

A156.15-06Release Devices-Closer Holder, Electromagnetic and Electromechanical
A156.16-08Auxiliary Hardware

A156.17-04 .............Self-Closing Hinges and Pivots A156.18-06 Materials and Finishes A156.20-06 .............Strap and Tee Hinges, and Hasps

A156.21-09Thresholds
A156.22-05Door Gasketing and Edge Seal Systems
A156.23-04Electromagnetic Locks
A156.24-03Delayed Egress Locking Systems

A156.25-07 .............Electrified Locking Devices A156.26-06 Continuous Hinges A156.28-07 .............Master Keying Systems A156.29-07 .............Exit Locks and Alarms A156.30-03 .............High Security Cylinders

A156.31-07Electric Strikes and Frame Mounted Actuators
A156.36-10Auxiliary Locks
A250.8-03Standard Steel Doors and Frames

National Fire Protection Association (NFPA):

80-10Fire Doors and Other Opening Protectives
101-09Life Safety Code

Underwriters Laboratories, Inc. (UL):

Building Materials Directory (2008) Architectural Barriers Act Accessibility Standards (ABAAS)

PRODUCTS

BUTT HINGES

ANSI A156.1. Provide only three-knuckle hinges, except five-knuckle where the required hinge type is not available in a three-knuckle version (e.g., some types of swing-clear hinges). The following types of butt hinges shall be used for the types of doors listed, except where otherwise specified:

Interior Doors: Type A8112/A5112 for doors 900 mm (3 feet) wide or less and Type A8111/A5111 for doors over 900 mm (3 feet) wide. Hinges for doors exposed to high humidity areas (shower rooms, toilet rooms, kitchens, janitor rooms, etc. shall be of stainless steel material.

Provide quantity and size of hinges per door leaf as follows:

1. Doors up to 1210 mm (4 feet) high: 2 hinges.

2. Doors 1210 mm (4 feet) to 2260 mm (7 feet 5 inches) high: 3 hinges minimum.

3. Doors greater than 2260 mm (7 feet 5 inches) high: 4 hinges.

4. Doors up to 900 mm (3 feet) wide, standard weight: 114 mm x 114 mm (4-1/2 inches x 4-1/2 inches) hinges.

5. Doors over 900 mm (3 feet) to 1065 mm (3 feet 6 inches) wide, standard weight: 127 mm x 114 mm (5 inches x 4-1/2 inches).

6. Doors over 1065 mm (3 feet 6 inches) to 1210 mm (4 feet), heavy weight: 127 mm x 114 mm (5 inches x 4-1/2 inches).

7. Provide heavy-weight hinges where specified.

8. At doors weighing 330 kg (150 pounds) or more, furnish 127 mm (5 inch) high hinges.

See Articles "MISCELLANEOUS HARDWARE" and "HARDWARE SETS" for pivots and hinges other than butts specified above and continuous hinges specified below.

CONTINUOUS HINGES

ANSI/BHMA A156.26, Grade 1-600.

Listed under Category N in BHMA's "Certified Product Directory."

General: Minimum 0.120-inch- (3.0-mm-) thick, hinge leaves with minimum overall width of 4 inches (102 mm); fabricated to full height of door and frame and to template screw locations; with components finished after milling and drilling are complete Continuous, Barrel-Type Hinges: Hinge with knuckles formed around a Teflon-coated 6.35mm (0.25-inch) minimum diameter pin that extends entire length of hinge.

Base Metal for Exterior Hinges: Stainless steel.

Base Metal for Interior Hinges: Steel.

Base Metal for Hinges for Fire-Rated Assemblies: Stainless steel.

Provide with non-removable pin (hospital tip option) at lockable outswing doors.

Where required to clear adjacent casing, trim, and wall conditions and allow full door swing, provide wide throw hinges of minimum width required.

Provide with manufacturer’s cut-outs for separate mortised power transfers and/or mortised automatic door bottoms where they occur.

Where thru-wire power transfers are integral to the hinge, provide hinge with easily removable portion to allow easy access to wiring connections.

Where models are specified that provide an integral wrap-around edge guard for the hinge edge of the door, provide manufacturer’s adjustable threaded stud and machine screw mechanism to allow the door to be adjusted within the wrap-around edge guard.

DOOR CLOSING DEVICES

Closing devices shall be products of one manufacturer.

OVERHEAD CLOSERS

Conform to ANSI A156.4, Grade 1.

Closers shall conform to the following:

The closer shall have minimum 50 percent adjustable closing force over minimum value for that closer and have adjustable hydraulic back check effective between 60 degrees and 85 degrees of door opening.

Where specified, closer shall have hold-open feature.

Size Requirements: Provide multi-size closers, sizes 1 through 6, except where multi-size closer is not available for the required application.

Material of closer body shall be forged or cast.

Arm and brackets for closers shall be steel, malleable iron or high strength ductile cast iron.

Where closers are exposed to the exterior or are mounted in rooms that experience high humidity, provide closer body and arm assembly of stainless steel material.

Closers shall have full size metal cover; plastic covers will not be accepted.

Closers shall have adjustable hydraulic back-check, separate valves for closing and latching speed, adjustable back-check positioning valve, and adjustable delayed action valve.

Provide closers with any accessories required for the mounting application, including (but not limited to) drop plates, special soffit plates, spacers for heavy-duty parallel arm fifth screws, bull-nose or other regular arm brackets, longer or shorter arm assemblies, and special factory templating. Provide special arms, drop plates, and templating as needed to allow mounting at doors with overhead stops and/or holders.

Closer arms or backcheck valve shall not be used to stop the door from overswing, except in applications where a separate wall, floor, or overhead stop cannot be used.

Provide parallel arm closers with heavy duty rigid arm.

Where closers are to be installed on the push side of the door, provide parallel arm type except where conditions require use of top jamb arm.

Provide all surface closers with the same body attachment screw pattern for ease of replacement and maintenance.

All closers shall have a 1 ½” (38mm) minimum piston diameter.

DOOR STOPS

Conform to ANSI A156.16.

Provide door stops wherever an opened door or any item of hardware thereon would strike a wall, column, equipment or other parts of building construction. For concrete, masonry or quarry tile construction, use expansion shields for mounting door stops.

Where cylindrical locks with turn pieces or pushbuttons occur, equip wall bumpers Type L02251 (rubber pads having concave face) to receive turn piece or button.

Provide floor stops (Type L02141 or L02161) in office areas; Type L02121 x 3 screws into floor elsewhere. Wall bumpers, where used, must be installed to impact the trim or the door within the leading half of its width. Floor stops, where used, must be installed within 4-inches of the wall face and impact the door within the leading half of its width.

Provide stop Type L02011, as applicable for exterior doors. At outswing doors where stop can be installed in concrete, provide stop mated to concrete anchor set in 76mm (3-inch) core-drilled hole and filled with quick-setting cement.

Omit stops where floor mounted door holders are required and where automatic operated doors occur.

Provide appropriate roller bumper for each set of doors (except where closet doors occur) where two doors would interfere with each other in swinging.

Provide appropriate door mounted stop on doors in individual toilets where floor or wall mounted stops cannot be used.

Provide door stops on doors where combination closer magnetic holders are specified, except where wall stops cannot be used or where floor stops cannot be installed within 4-inches of the wall.

Where the specified wall or floor stop cannot be used, provide concealed overhead stops (surface-mounted where concealed cannot be used).

OVERHEAD DOOR STOPS and HOLDERS Conform to ANSI Standard A156.8. Overhead holders shall be of sizes recommended by holder manufacturer for each width of door. Set overhead holders for 110 degree opening, unless limited by building construction or equipment. Provide Grade 1 overhead concealed slide type: stop-only at rated doors and security doors, hold-open type with exposed hold-open on/off control at all other doors requiring overhead door stops.

LOCKS AND LATCHES

Conform to ANSI A156.2. Locks and latches for doors 45 mm (1-3/4 inch) thick or over shall have beveled fronts. Lock cylinders shall have not less than seven pins. Cylinders for all locksets shall be removable core type. Cylinders shall be furnished with construction removable cores and construction master keys. Cylinder shall be removable by special key or tool. Construct all cores so that they will be interchangeable into the core housings of all mortise locks, rim locks, cylindrical locks, and any other type lock included in the Great Grand Master Key System. Disassembly of lever or lockset shall not be required to remove core from lockset. All locksets or latches on double doors with fire label shall have latch bolt with 19 mm (3/4 inch) throw, unless shorter throw allowed by the door manufacturer’s fire label. Provide temporary keying device or construction core to allow opening and closing during construction and prior to the installation of final cores.

In addition to above requirements, locks and latches shall comply with following requirements:

Mortise Lock and Latch Sets: Conform to ANSI/BHMA A156.13. Mortise locksets shall be series 1000, minimum Grade 2. All locksets and latchsets, except on designated doors in Psychiatric (Mental Health) areas, shall have lever handles fabricated from cast stainless steel. Provide sectional (lever x rose) lever design matching [__________]. No substitute lever material shall be accepted. All locks and latchsets shall be furnished with 122.55 mm (4-7/8-inch) curved lip strike and wrought box. At outswing pairs with overlapping astragals, provide flat lip strip with 21mm (7/8-inch) lip-to-center dimension. Lock function F02 shall be furnished with emergency tools/keys for emergency entrance. All lock cases installed on lead lined doors shall be lead lined before applying final hardware finish. Furnish armored fronts for all mortise locks. Where mortise locks are installed in high-humidity locations or where exposed to the exterior on both sides of the opening, provide non-ferrous mortise lock case.

Cylindrical Lock and Latch Sets: levers shall meet ADA (Americans with Disabilities Act) requirements. Cylindrical locksets shall be series 4000 Grade I. All locks and latchsets shall be furnished with 122.55 mm (4-7/8-inch) curved lip strike and wrought box. At outswing pairs with overlapping astragals, provide flat lip strip with 21mm (7/8-inch) lip-to-center dimension. Provide lever design to match design selected by Architect or to match existing lever design. Where two turn pieces are specified for lock F76, turn piece on inside knob shall lock and unlock inside knob, and turn piece on outside knob shall unlock outside knob when inside knob is in the locked position. (This function is intended to allow emergency entry into these rooms without an emergency key or any special tool.)

Auxiliary locks shall be as specified under hardware sets and conform to ANSI A156.36.

ELECTROMAGNETIC LOCKS

ANSI/BHMA A156.23; electrically powered, of strength and configuration indicated; with electromagnet attached to frame and armature plate attached to door. Listed under Category E in BHMA's "Certified Product Directory."

Type: Full exterior or full interior, as required by application indicated.

Strength Ranking: 1500 pound force (6672 N).

Inductive Kickback Peak Voltage: Not more than 0 V.

Residual Magnetism: Not more than 0 pound force (0 N) to separate door from magnet.

Delayed-Egress Locks: BHMA A156.24. Listed under Category G in BHMA's "Certified Product Directory".

Means of Egress Doors: Lock releases within 15 seconds after applying a force not more than 15 pound force (67 N) for not more than 3 seconds, as required by NFPA 101.

Security Grade: Activated from secure side of door by initiating device.

Movement Grade: Activated by door movement as initiating device.

The lock housing shall not project more than 4-inches (101mm) from the underside of the frame head stop.

ELECTRIC STRIKES

ANSI/ BHMA A156.31 Grade 1.

General: Use fail-secure electric strikes at fire-rated doors.

KEYS

Stamp all keys with change number and key set symbol. Furnish keys in quantities as follows:

Locks/Keys
Quantity
Cylinder locks
2 keys each
Cylinder lock change key blanks
100 each different key way
Master‑keyed sets
6 keys each
Grand Master sets
6 keys each
Great Grand Master set
5 keys
Control key
2 keys

Psychiatric keys shall be cut so that first two bittings closest to the key shoulder are shallow to provide greater strength at point of greatest torque.

KEY CABINET

ANSI Standard A156.11. Provide key cabinet made of cold rolled, 1.2 mm (0.0478 inch) thick furniture steel electro-welded. Doors shall have "no sag" continuous brass-pin piano type hinge and be equipped with chrome plated locking door handles, hook cam and mechanical pushbutton door lock. Key Cabinet and Key Control System shall accommodate all keys for this project plus 25 percent. Provide minimum number of multiple cabinets where a single cabinet of largest size will not accommodate the required number of keys.

Key tags shall consist of two sets: Permanent self-locking and loan key snaphook type with tag colors as follows: Red fiber marker of the permanent self-locking type approximately 32 mm (1-1/4 inch) in diameter engraved with the legend "FILE KEY MUST NOT BE LOANED." Also furnish for each hook a white cloverleaf key marker with snap-hooks engraved with the legend "LOAN KEY."

The manufacturer of the lock cylinders and locks shall attach a key tag to keys of each lock cylinder and shall mark thereon the respective item number and key change number. Provide each group of keys in a key gathering envelope (supplied by Key Cabinet Manufacturer) in which the lock manufacturer shall include the following information: Item number, key change number and door number. The contractor shall furnish the Key Cabinet Manufacturer the hardware and keying schedules and change keys.

The Key Cabinet Manufacturer shall set up a three-way cross index system, including master keys, listing the keys alphabetically, the hooks numerically and the key changes numerically on different colored index cards. Index cards shall be typewritten and inserted in a durable binder. Attach the keys to the two sets of numbered tags supplied with the cabinet. (The permanent tag and the loan key tag). Instruct the owner in proper use of the system. Install cabinet as directed by the COR.

ARMOR PLATES, KICK PLATES, MOP PLATES AND DOOR EDGING

Conform to ANSI Standard A156.6.

Provide protective plates as specified below:

Kick plates, mop plates and armor plates of metal, Type J100 series.

Provide kick plates and mop plates where specified. Kick plates shall be 254 mm (10 inches) or 305 mm (12 inches) high. Mop plates shall be 152 mm (6 inches) high. Both kick and mop plates shall be minimum 1.27 mm (0.050 inches) thick. Provide kick and mop plates beveled on all 4 edges (B4E). On push side of doors where jamb stop extends to floor, make kick plates 38 mm (1-1/2 inches) less than width of door, except pairs of metal doors which shall have plates 25 mm (1 inch) less than width of each door. Extend all other kick and mop plates to within 6 mm (1/4 inch) of each edge of doors. Kick and mop plates shall butt astragals. For jamb stop requirements, see specification sections pertaining to door frames.

Kick plates and/or mop plates are not required on following door sides:

Armor plate side of doors;

Exterior side of exterior doors;

Closet side of closet doors;

Both sides of aluminum entrance doors.

Armor plates for doors are listed under Article "Hardware Sets". Armor plates shall be thickness as noted in the hardware set, 875 mm (35 inches) high and 38 mm (1-1/2 inches) less than width of doors, except on pairs of metal doors. Provide armor plates beveled on all 4 edges (B4E). Plates on pairs of metal doors shall be 25 mm (1 inch) less than width of each door. Where top of intermediate rail of door is less than 875 mm (35 inches) from door bottom, extend armor plates to within 13 mm (1/2 inch) of top of intermediate rail. On doors equipped with panic devices, extend armor plates to within 13 mm (1/2 inch) of panic bolt push bar.

Where louver or grille occurs in lower portion of doors, substitute stretcher plate and kick plate in place of armor plate. Size of stretcher plate and kick plate shall be 254 mm (10 inches) high.

Provide stainless steel edge guards where so specified at wood doors. Provide mortised type instead of surface type except where door construction and/or ratings will not allow. Provide edge guards of bevel and thickness to match wood door. Provide edge guards with factory cut-outs for door hardware that must be installed through or extend through the edge guard. Provide full-height edge guards except where door rating does not allow; in such cases, provide edge guards to height of bottom of typical lockset armor front. Forward edge guards to wood door manufacturer for factory installation on doors.

EXIT DEVICES

Conform to ANSI Standard A156.3. Exit devices shall be Grade 1; type and function are specified in hardware sets. Provide flush with finished floor strikes for vertical rod exit devices in interior of building. Trim shall have cast satin stainless steel lever handles of design similar to locksets, unless otherwise specified. Provide key cylinders for keyed operating trim and, where specified, cylinder dogging.

Surface vertical rod panics shall only be provided less bottom rod; provide fire pins as required by exit device and door fire labels. Do not provide surface vertical rod panics at exterior doors.

Concealed vertical rod panics shall be provided less bottom rod at interior doors, unless lockable or otherwise specified; provide fire pins as required by exit device and door fire labels. Where concealed vertical rod panics are specified at exterior doors, provide with both top and bottom rods.

Where removable mullions are specified at pairs with rim panic devices, provide mullion with key-removable feature.

At non-rated openings with panic hardware, provide panic hardware with key cylinder dogging feature.

Exit devices for fire doors shall comply with Underwriters Laboratories, Inc., requirements for Fire Exit Hardware. Submit proof of compliance.

FLUSH BOLTS (LEVER EXTENSION)

Conform to ANSI A156.16. Flush bolts shall be Type L24081 unless otherwise specified. Furnish proper dustproof strikes conforming to ANSI A156.16, for flush bolts required on lower part of doors.

Lever extension manual flush bolts shall only be used at non-fire-rated pairs for rooms only accessed by maintenance personnel.

Face plates for cylindrical strikes shall be rectangular and not less than 25 mm by 63 mm (1 inch by 2-1/2 inches).

Friction‑fit cylindrical dustproof strikes with circular face plate may be used only where metal thresholds occur.

Provide extension rods for top bolt where door height exceeds 2184 mm (7 feet 2 inches).

FLUSH BOLTS (AUTOMATIC)

Conform to ANSI A156.3. Dimension of flush bolts shall conform to ANSI A115. Bolts shall conform to Underwriters Laboratories, Inc., requirements for fire door hardware. Flush bolts shall automatically latch and unlatch. Furnish dustproof strikes conforming to ANSI A156.16 for bottom flushbolt. Face plates for dustproof strike shall be rectangular and not less than 38 mm by 90 mm (1-1/2 by 3-1/2 inches).

At interior doors, provide auto flush bolts less bottom bolt, unless otherwise specified, except at wood pairs with fire-rating greater than 20 minutes; provide fire pins as required by auto flush bolt and door fire labels.

DOOR PULLS with plates Conform to ANSI A156.6. Pull Type J401, 152 mm CTC (6 inches CTC) length by 19 mm (3/4 inches) diameter minimum with plate Type J302, 90 mm by 381 mm (3-1/2 inches by 15 inches), unless otherwise specified. Provide pull with projection of 57.2 mm (2 1/4 inches) minimum and a clearance of 38.1 mm (1 1/2 inches) minimum. Cut plates of door pull plate for cylinders, or turn pieces where required.

PUSH PLATES

Conform to ANSI A156.6. Metal, Type J302, 203 mm (8 inches) wide by 406.4 mm (16 inches) high. Provide metal Type J302 plates 102 mm (4 inches) wide by 406.4 mm (16 inches) high where push plates are specified for doors with stiles less than 203 mm (8 inches) wide. Cut plates for cylinders, and turn pieces where required.

COMBINATION PUSH AND PULL PLATES

Conform to ANSI 156.6. Type J303, stainless steel 3 mm (1/8 inch) thick, 80 mm (3-1/3 inches) wide by 800 mm (16 inches) high), top and bottom edges shall be rounded. Secure plates to wood doors with 38 mm (1-1/2 inch) long No. 12 wood screws. Cut plates for turn pieces, and cylinders where required. Pull shall be mounted down.

COORDINATORS

Conform to ANSI A156.16. Coordinators, when specified for fire doors, shall comply with Underwriters Laboratories, Inc., requirements for fire door hardware. Coordinator may be omitted on exterior pairs of doors where either door will close independently regardless of the position of the other door. Coordinator may be omitted on interior pairs of non-labeled open where open back strike is used. Open back strike shall not be used on labeled doors. Paint coordinators to match door frames, unless coordinators are plated. Provide bar type coordinators, except where gravity coordinators are required at acoustic pairs. For bar type coordinators, provide filler bars for full width and, as required, brackets for push-side surface mounted closers, overhead stops, and vertical rod panic strikes.

THRESHOLDS

Conform to ANSI A156.21, mill finish extruded aluminum, except as otherwise specified. In existing construction, thresholds shall be installed in a bed of sealant with ¼-20 stainless steel machine screws and expansion shields. In new construction, embed aluminum anchors coated with epoxy in concrete to secure thresholds. Furnish thresholds for the full width of the openings.

For thresholds at elevators entrances see other sections of specifications.

At exterior doors and any interior doors exposed to moisture, provide threshold with non-slip abrasive finish.

Provide with miter returns where threshold extends more than 12 mm (0.5 inch) beyond face of frame.

AUTOMATIC DOOR BOTTOM SEAL AND RUBBER GASKET FOR LIGHT PROOF OR SOUND CONTROL DOORS Conform to ANSI A156.22. Provide mortise or under-door type, except where not practical. For mortise automatic door bottoms, provide type specific for door construction (wood or metal).

WEATHERSTRIPS (For Exterior Doors) Conform to ANSI A156.22. Air leakage shall not to exceed 0.50 CFM per foot of crack length (0.000774m3/s/m).

MISCELLANEOUS HARDWARE

Access Doors (including Sheet Metal, Screen and Woven Wire Mesh Types): Except for fire-rated doors and doors to Temperature Control Cabinets, equip each single or double metal access door with Lock Type E07213, conforming to ANSI A156.11. Key locks as directed. Ship lock prepaid to the door manufacturer. Hinges shall be provided by door manufacturer.

Cylinders for Various Partitions and Doors: Key cylinders same as entrance doors of area in which partitions and door occur, except as otherwise specified. Provide cylinders to operate locking devices where specified for following partitions and doors:

Folding doors and partitions.

Wicket door (in roll-up door assemblies).

Slide-up doors.

Swing-up doors.

Fire-rated access doors-Engineer's key set.

Doors from corridor to electromagnetic shielded room.

Day gate on vault door.

Mutes: Conform to ANSI A156.16. Provide door mutes or door silencers Type L03011 or L03021, depending on frame material, of white or light gray color, on each steel or wood door frame, except at fire-rated frames, lead-lined frames and frames for sound-resistant, lightproof and electromagnetically shielded doors. Furnish 3 mutes for single doors and 2 mutes for each pair of doors, except double-acting doors. Provide 4 mutes or silencers for frames for each Dutch type door. Provide 2 mutes for each edge of sliding door which would contact door frame.

PADLOCKS FOR VARIOUS DOORS, GATES AND HATCHES

ASTM E883, size 50 mm (2 inch) wide chain; furnish extended shackles as required by job conditions. Provide padlocks, with key cylinders, for each door in following areas as noted.

Key padlocks as follows:

Roof Access and Scuttles: Engineer's set.

FINISHES

Exposed surfaces of hardware shall have ANSI A156.18, finishes as specified below. Finishes on all hinges, pivots, closers, thresholds, etc., shall be as specified below under "Miscellaneous Finishes." For field painting (final coat) of ferrous hardware, see Section 09 91 00, PAINTING.

626 or 630: All surfaces on exterior and interior of buildings, except where other finishes are specified.

Miscellaneous Finishes:

Hinges --exterior doors: 626 or 630.

Hinges --interior doors: 652 or 630.

Pivots: Match door trim.

Door Closers: Factory applied paint finish. Dull or Satin Aluminum color.

Thresholds: Mill finish aluminum.

Cover plates for floor hinges and pivots: 630.

Other primed steel hardware: 600.

Special Finish: Exposed surfaces of hardware for dark bronze anodized aluminum doors shall have oxidized oil rubbed bronze finish (dark bronze) finish on door closers shall closely match doors.

BASE METALS

Apply specified U.S. Standard finishes on different base metals as following:

Finish
Base Metal
652
Steel
626
Brass or bronze
630
Stainless steel

EXECUTION

HARDWARE HEIGHTS

For new buildings locate hardware on doors at heights specified below, with all hand-operated hardware centered within 864 mm (34 inches) to 1200 mm (48 inches), unless otherwise noted:

Hardware Heights from Finished Floor:

Exit devices centerline of strike (where applicable) 1024 mm (40-5/16 inches).

Locksets and latch sets centerline of strike 1024 mm (40-5/16 inches).

Deadlocks centerline of strike 1219 mm (48 inches).

Hospital arm pull 1168 mm (46 inches) to centerline of bottom supporting bracket.

Centerline of door pulls to be 1016 mm (40 inches).

Push plates and push-pull shall be 1270 mm (50 inches) to top of plate.

Push-pull latch to be 1024 mm (40-5/16 inches) to centerline of strike.

Locate other hardware at standard commercial heights. Locate push and pull plates to prevent conflict with other hardware.

INSTALLATION

Closer devices, including those with hold-open features, shall be equipped and mounted to provide maximum door opening permitted by building construction or equipment. Closers shall be mounted on side of door inside rooms, inside stairs, and away from corridors. At exterior doors, closers shall be mounted on interior side. Where closers are mounted on doors they shall be mounted with hex nuts and bolts; foot shall be fastened to frame with machine screws. Door opening force shall not exceed 22.2 N (5 pounds) maximum in accordance with ABAAS. Measure and adjust opening force for all doors equipped with closers.

Hinge Size Requirements:

Door Thickness
Door Width
Hinge Height
45 mm (1-3/4 inch)
900 mm (3 feet) and less
113 mm (4-1/2 inches)
45 mm (1-3/4 inch)
Over 900 mm (3 feet) but

not more than 1200 mm (4 feet) 125 mm (5 inches)

35 mm (1‑3/8 inch) (hollow core wood doors)
Not over 1200 mm (4 feet)
113 mm (4-1/2 inches)

Hinge leaves shall be sufficiently wide to allow doors to swing clear of door frame trim and surrounding conditions.

Hinges Required Per Door:

Door Description
Number butts
Doors 1500 mm (5 ft) or less in height
2 butts
Doors over 1500 mm (5 ft) high and not over 2280 mm (7 ft 6 in) high
3 butts
Doors over 2280 mm (7 feet 6 inches) high
4 butts
Dutch type doors
4 butts
Doors with spring hinges 1370 mm (4 feet 6 inches) high or less
2 butts
Doors with spring hinges over 1370 mm (4 feet 6 inches)
3 butts

Fastenings: Suitable size and type and shall harmonize with hardware as to material and finish. Provide machine screws and lead expansion shields to secure hardware to concrete, ceramic or quarry floor tile, or solid masonry. Fiber or rawl plugs and adhesives are not permitted. All fastenings exposed to weather shall be of nonferrous metal.

After locks have been installed; show in presence of COR that keys operate their respective locks in accordance with keying requirements. (All keys, Master Key level and above shall be sent Registered Mail to the Medical Center Director along with the bitting list. Also a copy of the invoice shall be sent to the COR for his records.) Installation of locks which do not meet specified keying requirements shall be considered sufficient justification for rejection and replacement of all locks installed on project.

FINAL INSPECTION

Installer to provide letter to VA Resident/Project Engineer that upon completion, installer has visited the Project and has accomplished the following:

Re-adjust hardware.

Evaluate maintenance procedures and recommend changes or additions, and instruct VA personnel.

Identify items that have deteriorated or failed.

Submit written report identifying problems.

DEMONSTRATION

Demonstrate efficacy of mechanical hardware and electrical, and electronic hardware systems, including adjustment and maintenance procedures, to satisfaction of Resident/Project Engineer and VA Locksmith.

HARDWARE SETS

Following sets of hardware correspond to hardware symbols shown on drawings. Only those hardware sets that are shown on drawings will be required. Disregard hardware sets listed in specifications but not shown on drawings.

Hardware Consultant working on a project will be responsible for providing additional information regarding these hardware sets. The numbers shown in the following sets come from BHMA standards.

ELECTRIC HARDWARE ABBREVIATIONS LEGEND:

ADO = Automatic Door Operator EMCH = Electro-Mechanical Closer-Holder MHO = Magnetic Hold-Open (wall- or floor-mounted)

The hardware sets represent the design intent and direction of the owner and architect. Discrepancies, conflicting hardware and missing items should be brought to the attention of the architect with corrections made prior to the bidding process. Omitted items not included in a hardware set should be scheduled with the appropriate additional hardware required for proper application and functionality.

Quantities listed are for each pair of doors, or for each single door.

The supplier is responsible for handing and sizing all products.

Where multiple options for a piece of hardware are given in a single line item, the supplier shall provide the appropriate application for the opening.

At existing openings with new hardware the supplier shall field inspect existing conditions prior to the submittal stage to verify the specified hardware will work as required. Provide alternate solutions and proposals as needed.

Manufacturer’s Abbreviations:

1. MK - McKinney

2. SU - Securitron

3. RO - Rockwood

4. SA - SARGENT

5. RU - Corbin Russwin

6. YA - ASSA ABLOY ACCENTRA

7. RF - Rixson

8. NO - Norton

9. PE - Pemko

Sets:

Set: 1.0

Doors: 102B, 104B

Description: EXT ELEC / GEN PR

2
Continuous Hinge
CFM83HD 8-wire
AL
2
Electric Power Transfer*
EL-CEPT
630
⚡
1
Concealed VR, Exit Only
ED5800A M92
US32D
⚡
1
Concealed VR, Storeroom
ED5800A X L959ET M92
US32D
⚡
1
Cylinder housing - SFIC
as required
626
2
SFIC Core - 7-Pin
Supplied by VA
626
2
Surface Closer (C02021-Spg Stop)
CPS8501
689
1
Astragal
S772D [ mtg on mull ]
1
Astragal
18041CNB
1
Gasketing
303AS
1
Rain Guard
346C x LAR
2
Sweep
3452APK TKSP
1
Threshold (outswing door)
273x224AFGT
1
PACS Keypad
BY SECURITY SUPPLIER
2
Frame Harness
QC-C1500P
2
Door Harness
QC-C___
2
Position Switch
DPS-M/W -W As Required
1
Power Supply*
AQDxx (TO SUIT)

Notes: *Waiver may be required to comply with Buy American Act. Compliancy of this product to current Buy American-type regulations must be validated with the manufacturer.

Hardware listed for design purposes, verify with specific door mfg requirements for doors to meet DOD UDF 4-010-01 standards. Provide third party test results to verify product meets standards.

Electronic Operation: Valid card or key retracts latchbolt. Request to exit shows authorized egress. Free egress at all times. In case of power loss, door remains locked and latched.

Set: 2.0

Doors: 106

Description: EXT - FUEL YARD

2
Continuous Hinge
CFM83HD 8-WIRE
US32D
2
Electric Power Transfer*
EL-CEPT
630
⚡
1
Concealed VR, Exit Only
ED5800A M92
US32D
1
Concealed VR, Storeroom
ED5800A X L959ET M92
US32D
1
Cylinder housing - SFIC
as required
626
2
SFIC Core - 7-Pin
Supplied by VA
626
2
Surface Closer (C02021-Spg Stop)
CPS8501
689
2
Door Stop
463-RKW
US32D
1
PACS Keypad
BY SECURITY SUPPLIER
2
Frame Harness
QC-C1500P
2
Door Harness
QC-C___
2
Position Switch
DPS-M/W -W As Required
1
Power Supply*
AQDxx (TO SUIT)

Notes: *Waiver may be required to comply with Buy American Act. Compliancy of this product to current Buy American-type regulations must be validated with the manufacturer.

Hardware listed for design purposes, verify with specific door mfg requirements for doors to meet DOD UDF 4-010-01 standards. Provide third party test results to verify product meets standards.

Electronic Operation: Valid card or key retracts latchbolt. Request to exit shows authorized egress. Free egress at all times. In case of power loss, door remains locked and latched.

Set: 3.0

Doors: 101

Description: EXT - GENERATOR

1
Continuous Hinge
CFM83HD
US32D
1
Electric Power Transfer*
EL-CEPT
630
⚡
1
Rim Exit Device, Storeroom (Type 1,03, E01, E05)
ED5200A MELR SEC M92 X

L959ET

US32D
⚡
1
SFIC Core - 7-Pin
Supplied by VA
626
1
Surface Closer (C02021-Spg Stop)
CPS8501
689
1
Gasketing
303AS
1
Rain Guard
346C x LAR
1
Sweep
3452APK TKSP
1
Threshold (outswing door)
273x224AFGT
1
PACS Keypad
BY SECURITY SUPPLIER
1
Frame Harness
QC-C1500P
1
Door Harness
QC-C___
1
Position Switch
DPS-M/W -W As Required
1
Power Supply*
AQDxx (TO SUIT)

Notes: *Waiver may be required to comply with Buy American Act. Compliancy of this product to current Buy American-type regulations must be validated with the manufacturer.

Hardware listed for design purposes, verify with specific door mfg requirements for doors to meet DOD UDF 4-010-01 standards. Provide third party test results to verify product meets standards.

Electronic Operation: Valid card or key retracts latchbolt. Request to exit shows authorized egress. Free egress at all times. In case of power loss, door remains locked and latched.

Set: 4.0

Doors: 105

Description: EXT - MEP

2
Continuous Hinge
CFM83HD
US32D
1
Electric Power Transfer*
EL-CEPT
630
⚡
1
Storeroom/Closet Lock
ML2057 X LWA
US26D
⚡
1
SFIC Core - 7-Pin
Supplied by VA
626
1
Const Latching FB
2849
626
2
Surface Closer (C02021-Spg Stop)
CPS8501
689
1
Door Coordinator
1700
BL
1
Gasketing (R0Y154)
303AS
1
Rain Guard (R0Y976)
346C x LAR
2
Sweep (R3D534)
3452APK TKSP
1
Threshold (outswing door)
273x224AFGT
1
Frame Harness
QC-C1500P
1
Door Harness
QC-C___
2
Position Switch
DPS-M/W -W As Required
1
Power Supply*
AQDxx (TO SUIT)

Notes: *Waiver may be required to comply with Buy American Act. Compliancy of this product to current Buy American-type regulations must be validated with the manufacturer.

Hardware listed for design purposes, verify with specific door mfg requirements for doors to meet DOD UDF 4-010-01 standards. Provide third party test results to verify product meets standards.

Set: 5.0

Doors: 102A

Description: ELEC - RATED

1
Continuous Hinge
CFM83HD
US26D
1
Rim Exit Device, Storeroom (Type 1,03)
BAA 12 72 8804 ETP
US32D
1
SFIC Core - 7-Pin (E09241)
Supplied by VA
626
1
Surface Closer (C02021-Spg Stop)
CPS8501
689
1
Gasketing (R0Y154)
303AS

Notes: *Waiver may be required to comply with Buy American Act. Compliancy of this product to current Buy American-type regulations must be validated with the manufacturer.

Set: 6.0

Doors: 104A

Description: MEP PR - RATED

2
Continuous Hinge
CFM83HD
US26D
1
Concealed VR, Storeroom
ED5800A X L959ET M92
US32D
1
Concealed VR, Exit Only
ED5800A M92
US32D
1
Cylinder housing - SFIC
as required
626
1
SFIC Core - 7-Pin (E09241)
Supplied by VA
626
2
Surface Closer (C02021-Spg Stop)
CPS8501
689
1
Door Coordinator
1700
BL
1
Astragal (R0Y634)
357C
1
Gasketing (R0Y154)
303AS

Notes: *Waiver may be required to comply with Buy American Act. Compliancy of this product to current Buy American-type regulations must be validated with the manufacturer.

Set: 7.0

Doors: 102C, 107

Description: MEP - RATED

3
Hinge (A8111)
T4A3786 x USA
US26D
1
Passage/Closet Latch Set
ML2010 X LWA
US26D
1
Surface Closer (C02021-Spg Stop)
CPS8501
689
1
Door Stop
446
US26D
1
Gasketing (R0Y154)
S88BL

Notes: *Waiver may be required to comply with Buy American Act. Compliancy of this product to current Buy American-type regulations must be validated with the manufacturer.

- ‑ ‑ E N D ‑ ‑ ‑ 08 71 00-108