Pre-Renovation Asbestos Report.pdf
PDF 8 MB Posted
- Attached to
- Y1DB--Radiation Oncology Lab Renovation (Oct) Federal contract opportunity
- Solicitation number
- 36C24625B0001
About this file
This document is a Limited Asbestos-Containing Materials Survey Report for a renovation project at the Hunter Holmes McGuire VA Medical Center in Richmond, Virginia. The survey was conducted by Froehling & Robertson, Inc. to identify any asbestos-containing materials (ACMs) that may require special handling and disposal prior to the renovation of the first floor oncology examination and laboratory space. The survey included sampling and analysis of suspect materials such as flooring, drywall, caulking, and insulation. The results indicated that no ACMs were detected in the sampled materials. However, the report notes that some materials, such as fire door components and electrical system materials, were presumed to contain asbestos but were not sampled. The report provides recommendations for handling any newly discovered suspect ACMs that may be encountered during the renovation work.
The related federal contract opportunity is for the construction portion of this renovation project, Solicitation #36C24625B0001. This is an Invitation for Bids (IFB) issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6 for the Radiation Oncology Lab Renovation at the Richmond VA Medical Center. The project location is in Richmond, Virginia.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C24625B0001 0007.docx | DOCX document | |
| 36C24625B0001 0006.docx | DOCX document | |
| 36C24625B0001 0005.docx | DOCX document | |
| 36C24625B0001 0004.docx | DOCX document | |
| 36C24625B0001 0003.docx | DOCX document | |
| 36C24625B0001.Site.Visit.Sign-in.Sheet.pdf | ||
| 36C24625B0001 0002.docx | DOCX document | |
| 36C24625B0001 0001.docx | DOCX document | |
| Attachment B - Bid Specifications - Volume I R2.pdf | ||
| Attachment A - Wage Determination VA20240155 6.21.24.txt | TXT text file | |
| 36C24625B0001_1.docx | DOCX document | |
| Attachment D - Bid Drawings_R3.pdf | ||
| Attachment C - Bid Specifications - Volume II R2.pdf |
Show all 13
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Froehling & Robertson, Inc. 3015 Dumbarton Road Richmond, Virginia 23228 T 804.264.2701 www.fandr.com
A Minority-Owned Business
Update 2021 - winter
LIMITED ASBESTOS-CONTAINING MATERIALS SURVEY REPORT
VA Project #: 652-22-200 – Radiation/Oncology Exam Space Renovation
Hunter Holmes McGuire VA Medical Center 1201 Broad Rock Boulevard Richmond, Virginia 23249
Prepared For:
Charlotte Engineers, LLP 5838 Monroe Road #100
Charlotte, North Carolina 28212 Phone: 704.531.3000 x 106
Attention: Avery Callahan, MSME Email: ACallahan@charlotteengineers.com
Issue Date: March 29, 2022
F&R Project Number: 59A-0070
Prepared By:
Samuel D. Bedinger, MA Industrial Hygienist II
Conducted/Reviewed By:
E. Glenn Hargrove, CIH, CSP Practice Leader, Industrial Hygiene
Charlotte Engineers, LLP VA Project # 652-22-200 – Radiation/Oncology Exam Space Renovation F&R Project Number 59A-0070 i March 29, 2022
TABLE OF CONTENTS
1.0 INTRODUCTION
1.1. PURPOSE
1.2. SITE DESCRIPTION
2.0 SCOPE OF SERVICES
3.0 LIMITED ASBESTOS-CONTAINING MATERIALS SURVEY
3.1. ASBESTOS-CONTAINING MATERIALS (ACM) METHODOLOGY
3.2. ASBESTOS-CONTAINING MATERIALS FINDINGS
3.3. ASBESTOS-CONTAINING MATERIALS INVENTORY
3.3.1. Presumed Asbestos-Containing Materials
3.4. ASBESTOS-CONTAINING MATERIALS RECOMMENDATIONS
3.5. APPLICABLE REGULATIONS
3.5.1. EPA/NESHAP Regulations for Asbestos-Containing Materials
3.5.2. Virginia Asbestos Regulations
3.5.3. OSHA Asbestos Regulations
4.0 LIMITATIONS
APPENDICES
Appendix A
F&R Personnel and Laboratory Accreditations
Appendix B
Sample Location Figures:
Appendix C
Laboratory Certificates of Analysis Bulk Sample Chain of Custody Forms
Appendix D
Photolog
Charlotte Engineers, LLP VA Project # 652-22-200 – Radiation/Oncology Exam Space Renovation F&R Project Number 59A-0070 1 March 29, 2022
1.0 INTRODUCTION
Froehling & Robertson, Inc. (F&R) conducted limited asbestos-containing materials consulting services on February 28 and March 1, 2022 at the United States Department of Veterans Affairs Hunter Holmes McGuire Hospital located 1201 Broad Rock Boulevard in Richmond, Virginia. It is F&R’s understanding that the intent of the interior renovations is to develop radiation and oncology examination and laboratory space where offices, restrooms, examination rooms, lockers, and other occupied spaces currently exist. Renovation activities are anticipated to impact building materials. The following sections document the survey procedures and results. Refer to Appendix A for Personnel Accreditation documentation of F&R personnel associated with this survey.
1.1. Purpose
The purpose of the Limited Regulated Asbestos-Containing Materials Survey is to identify Asbestos-Containing Materials (ACMs) that may require appropriate removal, handling, and disposal procedures prior to scheduled renovation activities at the Subject Property. This survey is to aid in the determination of health and safety requirements during the conduct of work which may impact identified materials.
1.2. Site Description
The structure consists of multiple floors that are used primarily for medical purposes. The focus of this survey, the first floor oncology suite, includes occupied spaces with interior finishes comprising concrete masonry unit (CMU) structural interior walls, vinyl composite tile (VCT) flooring systems, gypsum wallboard systems, lay-in tile ceilings, among others. Located above the renovation area ceiling is an interstitial area which contains utility pipes and heating, ventilation, and air-conditioning (HVAC) ductwork. Refer to Appendix B for asbestos sample location diagrams of the areas of concern (AOC)
Note that F&R utilizes Housing and Urban Development methodology for location identification modifiers: Side A is always the address side or the main entry side of the building. Then, proceeding in a clockwise direction the adjacent sides are labeled B, C and D; for example, the wall on the left side as one enters the building would be denoted as side B. Site drawings outlining the AOC were furnished to F&R and were utilized in the development of this report. Refer to Appendix B for asbestos sample location diagrams.
It should be noted that material and color descriptions are subjective and that, due to the nature of the environment, identical materials and colors may have been labeled as different or the same depending on the lighting, other colors in the area, and other factors.
Charlotte Engineers, LLP VA Project # 652-22-200 – Radiation/Oncology Exam Space Renovation F&R Project Number 59A-0070 2 March 29, 2022
2.0 SCOPE OF SERVICES
As outlined in F&R Proposal for Asbestos and Industrial Hygiene Services – VA Project #: 652-22- 200 – Radiation/Oncology Exam Space Renovation, (F&R Proposal dated August 10, 2021) the survey included the following services with respect to the proposed renovation activities:
Identification and sampling, as necessary, of suspect ACMs for analysis.
Determination of the presence and location of identified ACMs.
Based on information provided by the client, it is F&R’s understanding that the extent of the interior renovations is the first floor oncology examination and laboratory space. Scheduled renovation work may include the removal of interior finishes within the offices, restrooms, examination rooms, lockers, and other occupied spaces which currently exist. Consequently, only those areas which are anticipated to be impacted by the renovation scope of work were included in this survey; the roof and the building exterior were excluded. As such, this survey as performed does not constitute a comprehensive building survey and this report shall not be utilized for the determination of presence or absence of Regulated Materials outside of the renovation area should the scope of work be altered or expanded beyond that of the currently scheduled upgrades and renovations.
3.0 LIMITED ASBESTOS-CONTAINING MATERIALS SURVEY
F&R’s Virginia Licensed Asbestos Building Inspector, Glenn Hargrove (Virginia Asbestos Inspector License #33003001281) additionally accredited by the Board for Global EHS Credentialing (BGC) as a Certified Industrial Hygienist (CIH 10730 CP) conducted the Asbestos Survey of the targeted areas of the Oncology department at the current site structure located at 1201 Broad Rock Boulevard, Richmond, Virginia on February 28, and March 1, 2022.
Federal Regulations (40 CFR Part 61, Subpart M – National Emission Standard for Asbestos (NESHAP)), as well as Virginia Department of Labor and Industry regulations require a thorough asbestos inspection of the structure to be conducted prior to the commencement of renovation and/or demolition activities. An ACM is defined by the Occupational Safety & Health Administration (OSHA) and the Environmental Protection Agency (EPA) as material containing greater than one percent (1%) asbestos.
3.1. Asbestos-Containing Materials (ACM) Methodology
This survey was conducted in general accordance with the Federal NESHAP and applicable State regulations for the presence of ACMs. The survey was characterized by a visual inspection and sampling of suspect building components at the subject property to be impacted by the proposed renovation/demolition activities.
Charlotte Engineers, LLP VA Project # 652-22-200 – Radiation/Oncology Exam Space Renovation F&R Project Number 59A-0070 3 March 29, 2022
Guidelines utilized in the asbestos survey were established by the EPA, ASTM International (ASTM), and The Environmental Information Association, Inc. (EIA). Utilized guidelines included:
the Asbestos Hazard Emergency Response Act (40 CFR Part 763, Subpart E – Asbestos-Containing Materials in Schools (cited as AHERA)), ASTM Standard E2356-14 Standard Practice for Comprehensive Building Asbestos Surveys, and the EIA publication Managing Asbestos in Buildings: A Guide for Owners and Managers – A Revision to the United States Environmental Protection Agency’s 1985 document Guidance for Controlling Asbestos-Containing Materials in Buildings (EPA 560/5-85-024) Known as the Purple Book.
F&R’s aforementioned Industrial Hygienist collected and submitted suspect asbestos-containing bulk samples to the laboratory, of which, a total of fifty-three (53) suspect asbestos-containing bulk samples with discernable layers were analyzed. Due to multiple layers, a total of ninety-four
(94) samples were analyzed.
Samples of suspect ACMs were organized as per the AHERA concept of Homogeneous Area (HA), collected, and transported to the Environmental Hazards Services, L.L.C. (EHS) testing laboratory.
EHS is a National Institute for Standards and Technology (NIST) National Voluntary Laboratory Accreditation Program (NVLAP) accredited laboratory (NVLAP Lab Code: 101882-0) and Virginia licensed asbestos laboratory, in Richmond, Virginia, for analysis by Polarized Light Microscopy (PLM) following EPA Method 600/R-93/116 and 600/M4-82-020. Refer to Appendix A for Laboratory Certificates of Accreditations. Refer to Appendix D for Laboratory Certificates of Analysis and Bulk Sample Chain of Custody Forms for further description of sampled materials/analytical results.
F&R collected bulk samples of roofing materials during this survey. Roof core sample locations were temporarily patched, as needed; however, F&R does not guarantee roof repairs and patches associated with sampling activities as F&R is not a professional roofer. Sampling activities were not coordinated with a professional roofing contractor; no contact information was provided or indicated as preferred by the Client. It is also noted that the roofing materials beneath the membrane covering were in a saturated condition on the day of the roof survey.
3.2. Asbestos-Containing Materials Findings
The following material types were identified, sampled, and accordingly homogenized based upon similar construction discovered during bulk sampling:
Flooring Materials Gypsum Wallboard Systems Thermal Systems Insulation Cementitious Packing Materials
Caulking/Sealants – Various Applications Mastics/Adhesives – Various Applications Ceramic Tile
Charlotte Engineers, LLP VA Project # 652-22-200 – Radiation/Oncology Exam Space Renovation F&R Project Number 59A-0070 4 March 29, 2022
The following table presents a summary of survey results from sampling events performed on February 28 and March 1, 2022. Refer to Appendix B for illustration of the approximate locations of collected bulk samples.
SUSPECT ASBESTOS-CONTAINING MATERIALS SAMPLE INFORMATION
HA
Sample # Situation1 Sample Location(s) Material
Description/Function Laboratory Description
Percent Asbestos
A 1 C1Z-1 Adjacent 1Z-105
12” X 12” Gray VCT with Gray Marbling and Black
Mastic
Gray Vinyl-Like (Tile)
NAD2
A 1 Black Adhesive
(Mastic)
NAD
B 1 C1Z-3 Adjacent 1Z-122
Gray Vinyl-Like (Tile) NAD
B 1 Black Adhesive
(Mastic)
NAD
C 1
Gray Vinyl-Like (Tile)
NAD
C 1 Black Adhesive
(Mastic)
NAD
A 1 C1Z-1 Adjacent 1Z-105
12” X 12” Salmon VCT with Marbling and Black
Mastic
Pink Vinyl-Like (Tile)
NAD
A Black Adhesive
(Mastic)
NAD
B 1 C1Z-3 Adjacent 1Z-122
Pink Vinyl-Like (Tile)
NAD
B Black Adhesive
(Mastic)
NAD
C
Pink Vinyl-Like (Tile) NAD
C Black Adhesive
(Mastic)
NAD
A 1 1Z-104
Carpet Mastic
Green Adhesive NAD
B 1 1Z-100 Tan Adhesive NAD
C 1 1Z-122 Tan Adhesive NAD
A
1Z-138 (Back Area Only)
12” X 12” Light Beige VCT and Black Mastic
Light Pink Vinyl-Like (Tile)
NAD
A Back/Yellow Adhesive
(Mastic) NAD
B
Light Pink Vinyl-Like (Tile)
NAD
B Back/Yellow Adhesive
(Mastic)
NAD
A
1Z-138
(Front Area Only) 12” X 12” Tan Marbled VCT and Black Mastic
Tan Vinyl-Like (Tile)
NAD
Yellow/Black Adhesive (Mastic)
B Tan Vinyl-Like NAD
Charlotte Engineers, LLP VA Project # 652-22-200 – Radiation/Oncology Exam Space Renovation F&R Project Number 59A-0070 5 March 29, 2022
(Tile)
Yellow/Black Adhesive (Mastic)
NAD
A 1 1Z-104
Grey Cove Base and Yellow Mastic
Gray Vinyl-Like (Cove Base)
NAD
Pale Yellow Pliable Adhesive (Mastic)
NAD
B 1 1Z-111
Gray Vinyl-Like (Cove Base)
NAD
Pale Yellow Pliable Adhesive (Mastic) NAD
A 1 Hall C1Z-1 Adjacent
1Z-100 Pink Cove Base and White
Mastic
Pink/Gray Vinyl-Like (Cove Base)
NAD
White Pliable Adhesive (Mastic)
NAD
B 1 Hall Adjacent 1Z-108
Pink/Gray Vinyl-Like (Cove Base)
NAD
White Pliable Adhesive (Mastic)
NAD
A 1 1Z-138
Green/Teal Covebase and Cream Mastic
Green Vinyl-Like (Cove Base)
NAD
Cream Adhesive (Mastic)
NAD
White Chalky (Joint Compound)
NAD
B 1 Hall Adjacent 1Z-130
Green Vinyl-Like (Cove Base) NAD
Cream Adhesive (Mastic)
NAD
White Chalky (Joint Compound)
NAD
A 1 Cart Nook Near 1Z-121
Brown Covebase and Cream Mastic
Gray Vinyl-Like (Cove Base)
NAD
Cream Adhesive (Mastic)
NAD
White Chalky (Joint Compound) NAD
B 1 Hall Adjacent 1Z-120
Gray Vinyl-Like (Cove Base)
NAD
Cream Adhesive (Mastic)
NAD
A 1 1Z-104
Cove Base Wall Backing Red/White Fibrous NAD B 1 1Z-120
11 A 1 1Z-105 White Sink Vibration Dampener Coating
White Soft NAD
12 A 1 1Z-112 12” X 12” White VCT and
Yellow Mastic White Vinyl-Like
Charlotte Engineers, LLP VA Project # 652-22-200 – Radiation/Oncology Exam Space Renovation F&R Project Number 59A-0070 6 March 29, 2022
Yellow Adhesive; Gray Cementitious
(Mastic)
NAD
B 1 1Z-112
White Vinyl-Like (Tile) NAD
Yellow/Black Adhesive (Mastic)
NAD
A 1.5 Interstitial Level Above 1st Floor
Fireproofing Beige Powdery;
Fibrous NAD B 1.5 Interstitial Level Above 1st Floor
C 1.5 Interstitial Level Above 1st Floor
A 1.5 Interstitial Level Above 1st Floor
White Caulk on TSI White Pliable NAD B 1.5 Interstitial Level Above 1st Floor
C 1.5 Interstitial Level Above 1st Floor
A 1.5 Interstitial Level Above 1st Floor
Gray Caulk Gray Pliable NAD B 1.5 Interstitial Level Above 1st Floor
A 1.5 Interstitial Level Above 1st Floor
Tan Caulk Beige Brittle Adhesive NAD B 1.5 Interstitial Level Above 1st Floor
A 1.5 Interstitial Level Above 1st Floor Cementitious Patch near
Base of Support Steel
White Brittle Granular NAD
B 1.5 Interstitial Level Above 1st Floor Tan Brittle Granular NAD
C 1.5 Interstitial Level Above 1st Floor
A 1.5 Interstitial Level Above 1st Floor 2” X 4” Ceiling Tile with
Large & Small Pits Beige Fibrous; White
Paint
NAD
B 1.5 Interstitial Level Above 1st Floor
A 1 1Z-104
Gypsum Wallboard and Joint Compound
Gray Powdery; Brown Fibrous (Drywall)
NAD
White Chalky (Joint Compound)
NAD
B 1 Corridor C1Z-1 Adjacent 1Z-107
Gray Powdery; Brown Fibrous (Drywall)
NAD
White Chalky (Joint Compound)
NAD
C 1 Corridor C1Z-3 Adjacent 1Z-117
Gray Powdery; Brown Fibrous (Drywall) NAD
White Chalky (Joint Compound)
NAD
D 1 Corridor C1Z-3 Adjacent 1Z-119
Gray Powdery; Brown Fibrous (Drywall)
NAD
White Chalky (Joint Compound)
NAD
E 1 Corridor C1Z-4 Adjacent 1Z-131
Gray Powdery; Brown Fibrous (Drywall)
NAD
White Chalky (Joint Compound)
NAD
F 1 Corridor C1Z-4 Adjacent 1Z-139 Gray Powdery; Brown
Fibrous (Drywall)
Charlotte Engineers, LLP VA Project # 652-22-200 – Radiation/Oncology Exam Space Renovation F&R Project Number 59A-0070 7 March 29, 2022
1Situation: 1 –First; 1.5 – Interstitial Level-Above 1st Floor;
2NAD: No Asbestos Detected
3.3. Asbestos-Containing Materials Inventory
F&R conducted a survey of the reasonably and safely accessible portions of the building to be impacted by the planned renovation. The building exterior was excluded due to those considerations as the scope of renovation is limited to the building interior.
Asbestos was not detected by the laboratory in samples collected and submitted for analysis. The white powder observed throughout the structure was studied by F&R personnel in Roanoke, Virginia. When exposed to diluted hydrochloric acid, the suspect powder effervesced quite readily. This is an indication that most of the material is calcium carbonate (CaCO3), which is the basic mineral in limestone and one of the primary components of the concrete CMU blocks. F&R
White Chalky (Joint Compound)
NAD
G 1 Corridor C1Z-4 Adjacent 1Z-139
Gray Powdery; Brown Fibrous (Drywall)
NAD
White Chalky (Joint Compound)
NAD
A 1 C1Z-1 Adjacent 1Z-108
Ceramic Tile with Grout and Mastic
Gray Hard Ceramic (Ceramic Tile)
NAD
Beige Granular (Grout)
NAD
Dark Yellow Brittle Adhesive (Mastic)
NAD
B 1 1Z-115
Beige Granular (Grout) NAD
Dark Yellow Brittle Adhesive (Mastic)
NAD
A 1 1Z-138 2’ X 2’ Ceiling Tile-Smooth
Surface-Gypsum Board White Powdery;
Brown Fibrous
NAD
B
A
12” X 12” Tan VCT and Tan Mastic
Beige/Tan Vinyl-Like (Tile)
Tan Adhesive (Mastic) NAD
Green Adhesive
(Mastic)
B
Beige/Tan Vinyl-Like
Tan Adhesive (Mastic) NAD
Green Adhesive
(Mastic)
NAD
A 1Z-113 Brown Brittle Cove Base
Mastic Dark Brown Brittle NAD B 1Z-113
Charlotte Engineers, LLP VA Project # 652-22-200 – Radiation/Oncology Exam Space Renovation F&R Project Number 59A-0070 8 March 29, 2022 personnel were unable to locate a CMU block that showed clear signs of efflorescence during the survey, however, the white powder is presumed to be emanating out of the CMU due to moisture condensation dissolving the CaCO3. The white powder is left when the moisture has evaporated. Additional white powder was observed on the grout for the brick indicating it as an additional source of the powder. This material would also be formed of calcium carbonate.
3.3.1. Presumed Asbestos-Containing Materials
During the conduct of this survey, sampling was limited to those materials which were within the areas designated by the client, which were safely accessible, and which were able to be sampled without damaging systems or structures. As such, some materials should be presumed to be positive, unless sampling is conducted and shown to be negative. Such presumed asbestos containing materials (PACMS) include, but are not limited to:
Fire door interiors and fire proof door frames, Electrical panel backing/arc deflectors/spark arresters, Vermiculite within masonry cells, Wiring insulation not tested or other live electrical system components, Et cetera.
As noted above, select building materials were excluded from the sampling and analysis;
however, without confirmation sampling, F&R cannot definitively affirm that detectable concentrations of asbestos in such materials are absent.
Note that asbestos was used in over 3,000 known products and was used extensively in construction materials including in insulation and finish materials such as gypsum board-based systems, acoustical tiles, caulks and mastics, vinyl-based materials, and specialty products.
Asbestos also continues to be used in new construction because, as stated by the EPA, "the manufacture, importation, processing, and distribution in commerce of [various] products […] are not banned.”
3.4. Asbestos-Containing Materials Recommendations
Laboratory analysis of the collected, submitted, and analyzed samples indicated an analytical result of “None Detected” with regard to asbestos content. Photographic Documentation of site conditions and sampled materials is provided as Appendix D.
Should additional suspect ACMs be discovered during renovation and/or demolition activities that have not been sampled and which will be disturbed, F&R recommends work that would affect those materials be temporarily halted. Samples of suspect materials should be collected, Charlotte Engineers, LLP VA Project # 652-22-200 – Radiation/Oncology Exam Space Renovation F&R Project Number 59A-0070 9 March 29, 2022 analyzed, and handled accordingly prior to the resumption of renovation and/or demolition activities.
F&R further recommends that an Asbestos Abatement Contractor, utilizing appropriately accredited personnel, be engaged to properly remove newly discovered ACMs prior to renovation and/or demolition activities. If asbestos abatement activities are performed within the building, the work should be performed by an appropriately licensed asbestos abatement contractor.
In addition, it should be noted that through NESHAP Applicability Determinations, asbestos bulk samples composed of friable materials which indicate a result of asbestos content to be less than ten (10) percent, including trace amounts (<1%) when analyzed via PLM, the material in question shall either be assumed to be an ACM or further analyzed via PLM Point Count or TEM to verify asbestos content. Quantitative results obtained via PLM Point Count or TEM analysis shall supersede previous qualitative results obtained by standard PLM analysis. Samples with analytical results via PLM which indicate that no asbestos was detected are not required to be further analyzed via PLM Point Count or TEM.
3.5. Applicable Regulations
3.5.1. EPA/NESHAP Regulations for Asbestos-Containing Materials
The U.S. Environmental Protection Agency promulgated the National Emission Standards for Hazardous Air Pollutants (NESHAP) [40 CFR Part 61], which addresses the application, removal, and disposal of asbestos-containing materials (ACM). Under NESHAP the following categories are defined for asbestos-containing materials:
Friable - When dry, can be crumbled, pulverized, or reduced to powder by hand pressure.
Non-friable - When dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.
Category I Non-friable ACM - Packings, gaskets, resilient floor coverings, and asphalt roofing products containing more than 1% asbestos.
Category II Non-friable ACM – Material, excluding Category I Non-friable ACM, which contains more than 1% asbestos.
Regulated Asbestos Containing Material (RACM) – One of the following:
1. Friable ACM
2. Category I Non-friable ACM that has become friable.
Charlotte Engineers, LLP VA Project # 652-22-200 – Radiation/Oncology Exam Space Renovation F&R Project Number 59A-0070 10 March 29, 2022
3. Category I Non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading.
4. Category II Non-friable ACM that has a high probability of becoming, or has become, friable by the forces expected to act on the material in the course of demolition or renovation operations.
Under NESHAP, the following actions are required:
1. Prior to the commencement of demolition or renovation activities, the building owner must inspect the affected facility or part of the facility where the demolition or renovation activities will occur for the presence of asbestos.
2. Remove RACM from the facility before activities begin that would break up, dislodge, or similarly disturb the material or preclude access for subsequent removal.
3. ACM need not be removed before demolition if:
a) It is Category I non-friable ACM that is not in poor condition.
b) It is on a facility component that is encased in concrete or other similar material and is adequately wet whenever exposed.
c) It was not accessible for testing and was therefore not discovered until after demolition began and because of the demolition the material cannot be safely removed.
d) It is Category II non-friable ACM and the probability is low that the material will become crumbled, pulverized, or reduced to powder during demolition.
3.5.2. Virginia Asbestos Regulations
The Virginia Department of Labor and Industry (DOLI) regulates asbestos through enforcement of the Virginia Occupational Safety and Health (VOSH) regulations, enforcement of the Environmental Protection Agency's National Emission Standards for Hazardous Air Pollutants (NESHAP), and enforcement of the Asbestos Notification regulations found in the Labor Laws of Virginia (§40.1-51.20). Agency locations and regulations can be found on the agency Web site http://www.doli.virginia.gov.
The Virginia Department of Professional and Occupational Regulation (DPOR) is responsible for company and individual licensure in Virginia. Licensure and regulatory information can be found on DPOR's Web site http://www.dpor.virginia.gov/
Charlotte Engineers, LLP VA Project # 652-22-200 – Radiation/Oncology Exam Space Renovation F&R Project Number 59A-0070 11 March 29, 2022
The Virginia Department of Environmental Quality (DEQ) is responsible for the regulation of landfills in Virginia. Information on the disposal of asbestos in Virginia landfills can be obtained from the DEQ Web site http://www.deq.state.va.us/.
3.5.3. OSHA Asbestos Regulations
The Occupational Safety and Health Administration (OSHA) regulates employee exposure to asbestos under 29 CFR 1926.1101 and 29 CFR 1910.1001. Work associated with known or suspect ACMs must be conducted according to these regulations in addition to the noted EPA regulations.
Charlotte Engineers, LLP VA Project # 652-22-200 – Radiation/Oncology Exam Space Renovation F&R Project Number 59A-0070 12 March 29, 2022
4.0 LIMITATIONS
This report has been prepared for the exclusive use of Charlotte Engineers, LLP and/or their agents. This service was performed in accordance with generally accepted environmental practices. No other warranty, expressed or implied, is made. Conclusions and recommendations are based, in part, upon information provided to us by others and site observations. We have not verified the completeness or accuracy of the information provided by others, unless otherwise noted. Observations and recommendations are based upon conditions readily visible at the site at the time of the site visit, and upon current industry standards.
During this study, suspect asbestos samples were submitted for analysis at a NVLAP-accredited laboratory via polarized light microscopy. Invasive and destructive sampling methods were used;
however, these were not exhaustive. Inaccessible areas, such as behind solid ceilings or behind solid walls were not surveyed; therefore, some target materials may not have been identified. As with similar surveys of this nature, actual conditions exist only at the precise locations from which samples were collected or tested. Areas inspected were limited to those designated by the scope of services by the Client. Certain inferences are based on the results of this sampling and related testing to form a professional opinion of conditions in areas beyond those from which the samples were collected. Unless otherwise noted, F&R does not claim to have performed exhaustive delineation and/or quantification of identified materials; it is the responsibility of the client or abatement contractor to verify locations and quantities of regulated materials. Visual evaluation of other materials of concern conducted comprised a cursory visual review of the building materials and, to a limited extent, contents of the facility. It is also understood that this is a not an exhaustively invasive survey so that it is possible that concealed materials may be present that were not accessible during the original survey. No other warranty, expressed or implied, is made.
Reasonable effort was made by inspection personnel to locate and sample suspect materials within the structure with regard to the scope of services. However, for a facility, the existence of unique or concealed ACMs and debris is a possibility. F&R does not warrant, guarantee or profess to have the ability to locate or identify all ACMs, or other chemicals of concern in a facility.
Under this scope of services, F&R assumes no responsibility regarding response actions (e.g.
O&M Plans, Encapsulation, Abatement, Removal, Tenant Notification, etc.) initiated as a result of these findings. F&R assumes no liability for the duties and responsibilities of the Client with respect to compliance with appropriate regulations. Compliance with regulations and response actions are the sole responsibility of the Client and should be conducted in accordance with local, state, and/or federal requirements and should be performed by appropriately qualified and licensed/accredited personnel, as warranted.
Froehling & Robertson, Inc. by virtue of providing the services described in this report, does not assume the responsibility of the person(s) in charge of the site, or otherwise undertake responsibility for reporting to local, state, or federal public agencies conditions at the site that may present a potential danger to public health, safety, or the environment. The Client agrees to
Charlotte Engineers, LLP VA Project # 652-22-200 – Radiation/Oncology Exam Space Renovation F&R Project Number 59A-0070 13 March 29, 2022 notify the appropriate local, state, or federal public agencies as required by law, or otherwise to disclose, in a timely manner, information that may be necessary to prevent danger to public health, safety, or the environment. The contents of the report should not be construed in any way as a recommendation to purchase, sell, or develop the project site. F&R retains the right to revise this report if new information is later discovered or made available. The report must be presented in its entirety.
Charlotte Engineers, LLP. VA Project # 652-22-200 – Radiation/Oncology Exam Space Renovation F&R Project Number 59A-0070 March 29, 2022
Appendix A
F&R Personnel and Laboratory Accreditations
3/29/22, 10:34 AM License Lookup: License Search Results https://dporweb.dpor.virginia.gov/LicenseLookup/LicenseDetail 1/1
DPOR License Lookup License Number 3303001281
License Details Name HARGROVE, ERNEST GLENN
License Number 3303001281 License Description Asbestos Inspector License
Rank Asbestos Inspector Address ROANOKE, VA 24019
Initial Certification Date 1990-12-27 Expiration Date 2023-03-31
The data located on this website are not the public records of the Department of Professional and Occupational Regulation (DPOR). All public records are physically located at DPOR's Public Records Section: 9960 Mayland Drive, Suite 400, Richmond, VA 23233. While DPOR works to ensure the accuracy of the data provided online, the data available on these pages are updated routinely but may not be up to date at all times (due to document processing delays, technical maintenance, etc.).
DPOR assumes no liability for any errors, omissions, or inaccuracies in the information provided or for any reliance on data provided online. While DPOR has attempted to ensure that the data contained herein are accurate and reflect the status of its regulants, DPOR makes no warranties, expressed or implied, concerning the accuracy, completeness, reliability, or suitability of this data. If discrepancies or errors are discovered, please inform DPOR so that appropriate action may be taken.
DPOR License Lookup build 1,452 (built 2021-09-14 01:36:33).
Charlotte Engineers, LLP. VA Project # 652-22-200 – Radiation/Oncology Exam Space Renovation
Appendix B
Sample Location Figures
Asbestos Sample Location Figure Froehling & Robertson, Inc.
1734 Seibel Drive N.E.
Roanoke, VA 24012
T 540.344.7939
Client:
Project:
Location:
Project Number:
Issue Date:
Charlotte Engineers VA Project #: 652-22-200 AE Radiation Oncology Lab Renovation McGuire VAMC-1201 Broad Rock Boulevard, Richmond, Virginia 59A-0070 Pre-Renovation Asbestos Inspection 03-29-2022
FIGURE
No. 1
Scale: Not To Scale
1A
1B
2A
2B
3A
3B
6A
7A7B
9A
9B
10A
10B
11A
12A
12B
18A
18B
19A
19B
19C
19D
20A
20B
22A
22B
23A
3C
Asbestos Sample Location Figure
1734 Seibel Drive N.E.
Roanoke, VA 24012
T 540.344.7939
Client:
Project:
Location:
Project Number:
Issue Date:
Charlotte Engineers VA Project #: 652-22-200 AE Radiation Oncology Lab Renovation McGuire VAMC-1201 Broad Rock Boulevard, Richmond, Virginia 59A-0070 Pre-Renovation Asbestos Inspection 03-29-2022
FIGURE
No. 2
Scale: Not To Scale
2C1C19F19G
19E8B
8A
5B5A
21B
21A4B
4A
Asbestos Sample Location Figure-Interstitial Space
1734 Seibel Drive N.E.
Roanoke, VA 24012
T 540.344.7939
Client:
Project:
Location:
Project Number:
Issue Date:
Charlotte Engineers VA Project #: 652-22-200 AE Radiation Oncology Lab Renovation McGuire VAMC-1201 Broad Rock Boulevard, Richmond, Virginia 59A-0070 Pre-Renovation Asbestos Inspection 03-29-2022
FIGURE
No. 3
Scale: Not To Scale
13A
13B
13C
14A
14B
14C
15A
15B
16A
16B
17A
17B
Charlotte Engineers, LLP. VA Project # 652-22-200 – Radiation/Oncology Exam Space Renovation
Appendix C
Laboratory Certificates of Analysis Bulk Sample Chain of Custody Forms
Asbestos Bulk Analysis Report
Client:
Report Number:
Project/Test Address:
Client Number:
Reported Date:
Received Date:
Analyzed Date:
Froehling & Robertson - Richmond 03/07/2022
48-2016
03/10/2022
22-03-01453
7469 Whitepine Rd
Telephone: 800.347.4010
Richmond, VA 23237
Environmental Hazards Services, L.L.C.
59A0070-000001; McGuire VAMC - Oncology; Richmond, VA
Laboratory Results Fax Number:
804-266-1275
3015 Dumbarton Road Richmond, VA 23228
03/08/2022, 03/09/2022
Layer Type AsbestosClient Sample Number
Other Materials
Lab Gross DescriptionLab Sample Number
Gray Vinyl-Like;
Homogenous
22-03-01453-001A 1A 100% Non-FibrousTile NAD
Black Adhesive;
Homogenous
22-03-01453-001B 1A 5% Polyethylene 95% Non-Fibrous
Mastic NAD
Gray Vinyl-Like;
Homogenous
22-03-01453-002A 1B 100% Non-FibrousTile NAD
Black Adhesive;
Homogenous
22-03-01453-002B 1B 100% Non-FibrousMastic NAD
Gray Vinyl-Like;
Homogenous
22-03-01453-003A 1C 100% Non-FibrousTile NAD
1 of 13Page
Black Adhesive;
Homogenous
22-03-01453-003B 1C 3% Polyethylene 97% Non-Fibrous
Mastic NAD
Pink Vinyl-Like;
Homogenous
22-03-01453-004A 2A 100% Non-FibrousTile NAD
Black Adhesive;
Homogenous
22-03-01453-004B 2A 4% Polyethylene 96% Non-Fibrous
Mastic NAD
Pink Vinyl-Like;
Homogenous
22-03-01453-005A 2B 100% Non-FibrousTile NAD
Black Adhesive;
Homogenous
22-03-01453-005B 2B 2% Polyethylene 98% Non-Fibrous
Mastic NAD
Pink Vinyl-Like;
Homogenous
22-03-01453-006A 2C 100% Non-FibrousTile NAD
Black Adhesive;
Homogenous
22-03-01453-006B 2C 2% Polyethylene 98% Non-Fibrous
Mastic NAD
Green Adhesive;
Homogenous
22-03-01453-007 3A 4% Synthetic 96% Non-Fibrous
NAD
Environmental Hazards Services, L.L.C
Project/Test Address:
Client Number: Report Number:48-2016 22-03-01453
59A0070-000001; McGuire VAMC - Oncology; Richmond, VA
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample Number
2 of 13Page
Tan Adhesive;
22-03-01453-008 3B 5% Synthetic 95% Non-Fibrous
NAD
Tan Adhesive;
Homogenous
22-03-01453-009 3C 3% Synthetic 97% Non-Fibrous
NAD
Light Pink Vinyl-Like;
Homogenous
22-03-01453-010A 4A 100% Non-FibrousTile NAD
Black/Yellow Adhesive;
Homogenous
22-03-01453-010B 4A 100% Non-FibrousMastic NAD
Unable to separate.
Light Pink Vinyl-Like;
Homogenous
22-03-01453-011A 4B 100% Non-FibrousTile NAD
Black/Yellow Adhesive;
Homogenous
22-03-01453-011B 4B 100% Non-FibrousMastic NAD
Unable to separate.
Tan Vinyl-Like;
Homogenous
22-03-01453-012A 5A 100% Non-FibrousTile NAD
Yellow/Black Adhesive;
Inhomogenous
22-03-01453-012B 5A 100% Non-FibrousMastic NAD
Unable to separate.
Environmental Hazards Services, L.L.C
Project/Test Address:
Client Number: Report Number:48-2016 22-03-01453
59A0070-000001; McGuire VAMC - Oncology; Richmond, VA
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample
3 of 13Page
Tan Vinyl-Like;
22-03-01453-013A 5B 100% Non-FibrousTile NAD
Yellow/Black Adhesive;
Inhomogenous
22-03-01453-013B 5B 100% Non-FibrousMastic NAD
Unable to separate.
Gray Vinyl-Like;
Homogenous
22-03-01453-014A 6A 100% Non-FibrousCove Base
NAD
Pale Yellow Pliable Adhesive; Homogenous
22-03-01453-014B 6A 100% Non-FibrousMastic NAD
White Chalky;
Homogenous
22-03-01453-014C 6A 100% Non-FibrousJoint Comp.
NAD
Gray Vinyl-Like;
Homogenous
22-03-01453-015A 6B 100% Non-FibrousCove Base
NAD
Pale Yellow Pliable Adhesive; Homogenous
22-03-01453-015B 6B 100% Non-FibrousMastic NAD
Pink/Gray Vinyl-Like;
Homogenous
22-03-01453-016A 7A 100% Non-FibrousCove Base
NAD
Environmental Hazards Services, L.L.C
Project/Test Address:
Client Number: Report Number:48-2016 22-03-01453
59A0070-000001; McGuire VAMC - Oncology; Richmond, VA
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample
4 of 13Page
White Pliable Adhesive;
22-03-01453-016B 7A 100% Non-FibrousMastic NAD
Pink/Gray Vinyl-Like;
Homogenous
22-03-01453-017A 7B 100% Non-FibrousCove Base
NAD
White Pliable Adhesive;
Homogenous
22-03-01453-017B 7B 100% Non-FibrousMastic NAD
Green Vinyl-Like;
Homogenous
22-03-01453-018A 8A 100% Non-FibrousCove Base
NAD
Cream Adhesive;
Homogenous
22-03-01453-018B 8A 100% Non-FibrousMastic NAD
White Chalky;
Homogenous
22-03-01453-018C 8A 100% Non-FibrousJoint Comp.
NAD
Green Vinyl-Like;
Homogenous
22-03-01453-019A 8B 100% Non-FibrousCove Base
NAD
Cream Pliable Adhesive;
Homogenous
22-03-01453-019B 8B 100% Non-FibrousMastic NAD
Environmental Hazards Services, L.L.C
Project/Test Address:
Client Number: Report Number:48-2016 22-03-01453
59A0070-000001; McGuire VAMC - Oncology; Richmond, VA
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample
5 of 13Page
White Chalky;
22-03-01453-019C 8B 100% Non-FibrousJoint Comp.
NAD
Gray Vinyl-Like;
Homogenous
22-03-01453-020A 9A 100% Non-FibrousCove Base
NAD
Cream Adhesive;
Homogenous
22-03-01453-020B 9A 100% Non-FibrousMastic NAD
White Chalky;
Homogenous
22-03-01453-020C 9A 100% Non-FibrousJoint Comp.
NAD
Gray Vinyl-Like;
Homogenous
22-03-01453-021A 9B 100% Non-FibrousCove Base
NAD
Cream Adhesive;
Homogenous
22-03-01453-021B 9B 100% Non-FibrousMastic NAD
Red/White Fibrous;
Pliable; Homogenous
22-03-01453-022 10A 75% Fibrous Glass 25% Non-Fibrous
NAD
Red/White Fibrous;
Pliable; Homogenous
22-03-01453-023 10B 75% Fibrous Glass 25% Non-Fibrous
NAD
Environmental Hazards Services, L.L.C
Project/Test Address:
Client Number: Report Number:48-2016 22-03-01453
59A0070-000001; McGuire VAMC - Oncology; Richmond, VA
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample
6 of 13Page
White Soft; Homogenous22-03-01453-024 11A 3% Cellulose 97% Non-Fibrous
NAD
White Vinyl-Like;
Homogenous
22-03-01453-025A 12A 100% Non-FibrousTile NAD
Yellow Adhesive; Gray Cementitious;
Inhomogenous
22-03-01453-025B 12A 100% Non-FibrousMastic NAD
Unable to separate.
White Vinyl-Like;
Homogenous
22-03-01453-026A 12B 100% Non-FibrousTile NAD
Yellow/Black Adhesive;
Inhomogenous
22-03-01453-026B 12B 100% Non-FibrousMastic NAD
Unable to separate.
Beige Powdery; Fibrous;
Homogenous
22-03-01453-027 13A 10% Cellulose 15% Fibrous Glass 75% Non-Fibrous
NAD
Beige Powdery; Fibrous;
Homogenous
22-03-01453-028 13B 10% Cellulose 15% Fibrous Glass 75% Non-Fibrous
NAD
Beige Powdery; Fibrous;
Homogenous
22-03-01453-029 13C 10% Cellulose 15% Fibrous Glass 75% Non-Fibrous
NAD
Environmental Hazards Services, L.L.C
Project/Test Address:
Client Number: Report Number:48-2016 22-03-01453
59A0070-000001; McGuire VAMC - Oncology; Richmond, VA
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample
7 of 13Page
White Pliable;
22-03-01453-030 14A 100% Non-FibrousNAD
White Pliable;
Homogenous
22-03-01453-031 14B 100% Non-FibrousNAD
White Pliable;
Homogenous
22-03-01453-032 14C 100% Non-FibrousNAD
Gray Pliable;
Homogenous
22-03-01453-033 15A 100% Non-FibrousNAD
Gray Pliable;
Homogenous
22-03-01453-034 15B 100% Non-FibrousNAD
Beige Brittle Adhesive;
Homogenous
22-03-01453-035 16A 100% Non-FibrousNAD
Beige Brittle Adhesive;
Homogenous
22-03-01453-036 16B 100% Non-FibrousNAD
White Brittle Granular;
Homogenous
22-03-01453-037 17A 100% Non-FibrousNAD
Environmental Hazards Services, L.L.C
Project/Test Address:
Client Number: Report Number:48-2016 22-03-01453
59A0070-000001; McGuire VAMC - Oncology; Richmond, VA
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample
8 of 13Page
Tan Brittle Granular;
22-03-01453-038 17B 100% Non-FibrousNAD
Tan Brittle Granular;
Homogenous
22-03-01453-039 17C 100% Non-FibrousNAD
Beige Fibrous; White Paint; Homogenous
22-03-01453-040 18A 65% Cellulose 20% Fibrous Glass 15% Non-Fibrous
NAD
Beige Fibrous; White Paint; Homogenous
22-03-01453-041 18B 65% Cellulose 20% Fibrous Glass 15% Non-Fibrous
NAD
Gray Powdery; Brown Fibrous; Inhomogenous
22-03-01453-042A 19A 12% Cellulose 88% Non-Fibrous
Drywall NAD
White Chalky;
Homogenous
22-03-01453-042B 19A 100% Non-FibrousJoint Comp.
NAD
Gray Powdery; Brown Fibrous; Inhomogenous
22-03-01453-043A 19B 15% Cellulose 85% Non-Fibrous
Drywall NAD
White Chalky;
Homogenous
22-03-01453-043B 19B 100% Non-FibrousJoint Comp.
NAD
Environmental Hazards Services, L.L.C
Project/Test Address:
Client Number: Report Number:48-2016 22-03-01453
59A0070-000001; McGuire VAMC - Oncology; Richmond, VA
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample
9 of 13Page
Gray Powdery; Brown Fibrous; Inhomogenous
22-03-01453-044A 19C 15% Cellulose 85% Non-Fibrous
Drywall NAD
White Chalky;
Homogenous
22-03-01453-044B 19C 100% Non-FibrousJoint Comp.
NAD
Gray Powdery; Brown Fibrous; Inhomogenous
22-03-01453-045A 19D 12% Cellulose 88% Non-Fibrous
Drywall NAD
White Chalky;
Homogenous
22-03-01453-045B 19D 100% Non-FibrousJoint Comp.
NAD
Gray Powdery; Brown Fibrous; Inhomogenous
22-03-01453-046A 19E 12% Cellulose 88% Non-Fibrous
Drywall NAD
White Chalky;
Homogenous
22-03-01453-046B 19E 100% Non-FibrousJoint Comp.
NAD
Gray Powdery; Brown Fibrous; Inhomogenous
22-03-01453-047A 19F 12% Cellulose 88% Non-Fibrous
Drywall NAD
White Chalky;
Homogenous
22-03-01453-047B 19F 100% Non-FibrousJoint Comp.
NAD
Environmental Hazards Services, L.L.C
Project/Test Address:
Client Number: Report Number:48-2016 22-03-01453
59A0070-000001; McGuire VAMC - Oncology; Richmond, VA
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample
10 of 13Page
Gray Powdery; Brown
22-03-01453-048A 19G 15% Cellulose 85% Non-Fibrous
Drywall NAD
White Chalky;
Homogenous
22-03-01453-048B 19G 100% Non-FibrousJoint Comp.
NAD
Gray Hard Ceramic;
Homogenous
22-03-01453-049A 20A 100% Non-FibrousCeramic Tile
NAD
Beige Granular;
Homogenous
22-03-01453-049B 20A 100% Non-FibrousGrout NAD
Dark Yellow Brittle Adhesive; Homogenous
22-03-01453-049C 20A 2% Cellulose 98% Non-Fibrous
Mastic NAD
Beige Granular;
Homogenous
22-03-01453-050A 20B 100% Non-FibrousGrout NAD
Yellow Brittle Adhesive;
Homogenous
22-03-01453-050B 20B 2% Cellulose 98% Non-Fibrous
Mastic NAD
White Powdery; Brown Fibrous; Inhomogenous
22-03-01453-051 21A 12% Cellulose 88% Non-Fibrous
NAD
Environmental Hazards Services, L.L.C
Project/Test Address:
Client Number: Report Number:48-2016 22-03-01453
59A0070-000001; McGuire VAMC - Oncology; Richmond, VA
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample
11 of 13Page
White Powdery; Brown
22-03-01453-052 21B 12% Cellulose 88% Non-Fibrous
NAD
Beige/Tan Vinyl-Like;
Homogenous
22-03-01453-053A 22A 100% Non-FibrousTile NAD
Tan Adhesive;
Homogenous
22-03-01453-053B 22A 100% Non-FibrousMastic NAD
Green Adhesive;
Homogenous
22-03-01453-053C 22A 100% Non-FibrousMastic NAD
Beige/Tan Vinyl-Like;
Homogenous
22-03-01453-054A 22B 100% Non-FibrousTile NAD
Tan Adhesive;
Homogenous
22-03-01453-054B 22B 100% Non-FibrousMastic NAD
Green Adhesive;
Homogenous
22-03-01453-054C 22B 100% Non-FibrousMastic NAD
Dark Brown Brittle;
Homogenous
22-03-01453-055 23A 100% Non-FibrousNAD
Environmental Hazards Services, L.L.C
Project/Test Address:
Client Number: Report Number:48-2016 22-03-01453
59A0070-000001; McGuire VAMC - Oncology; Richmond, VA
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample
12 of 13Page
Environmental Hazards Services, L.L.C
Project/Test Address:
Client Number: Report Number:48-2016 22-03-01453
59A0070-000001; McGuire VAMC - Oncology; Richmond, VA
Other Materials
AsbestosLab Sample Number
Layer Type Lab Gross DescriptionClient Sample Number
Dark Brown Brittle;
Homogenous
22-03-01453-056 23B 100% Non-FibrousNAD
Tasha Eaddy
1% Asbestos
Analyst:
Reporting Limit:
Method:
QC Blank:
QC Sample:
Kay Harris
EPA Method 600/R-93/116, EPA Method 600/M4-82-020
QA/QC Clerk
Reviewed By Authorized Signatory:
48-M12017-2, 41-M22019-2
SRM 1866 Fiberglass
NAD = no asbestos detectedLEGEND:
The condition of the samples analyzed was acceptable upon receipt per laboratory protocol unless otherwise noted on this report. Each distinct component in an inhomogeneous sample was analyzed separately and reported as a composite. Results represent the analysis of samples submitted by the client. Sample location, description, area, volume, etc., was provided by the client. This report cannot be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without the written consent of the
Environmental Hazards Service, L.L.C. California Certification #2319 NY ELAP #11714 NVLAP #101882-0 VELAP 460172. All information concerning sampling location, date, and time can be found on Chain-of-Custody. Environmental Hazards Services, L.L.C. does not perform any sample collection.
Environmental Hazards Services, L.L.C. recommends reanalysis by point count (for more accurate quantification) or Transmission Electron Microscopy
(TEM), (for enhanced detection capabilities) for materials regulated by EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by polarized light microscopy (PLM). Both services are available for an additional fee.
400 Point Count Analysis, where noted, performed per EPA Method 600/R-93/116 with a Reporting Limit of 0.25%.
* All California samples analyzed by Polarized Light Microscopy, EPA Method 600/M4-82-020, Dec. 1982.
13 of 13Page
Charlotte Engineers, LLP. VA Project # 652-22-200 – Radiation/Oncology Exam Space Renovation
Appendix D
Photographic Documentation
Department of Veteran’s Affairs Project 652-22-200 McGuire VAMC-Renovate Radia!on Oncology Lab Space
2. Carpet mas�c designated as Homogeneous Area 3 in the report and considered representa�ve of all carpet mas�c in the study area.
No asbestos was detected in the carpet mas�c.
1. View of the 12” X 12” composite vinyl floor �les and associated mas�c designated as Homogeneous Areas 1 and 2 in the report. No asbestos was detected in the floor �les or the mas�cs.
Department of Veteran’s Affairs Project 652-22-200 McGuire VAMC-Renovate Radia!on Oncology Lab Space
4. View of the 12” X 12” composite vinyl floor �le and associated mas�c designated as Homogeneous Area 5. No asbestos was detected in the floor �le or mas�c.
3. View of the 12” X 12” composite vinyl floor �le and associated mas�c designated as Homogeneous Area 4. No asbestos was detected in the floor �le or mas�c.
Department of Veteran’s Affairs Project 652-22-200 McGuire VAMC-Renovate Radia!on Oncology Lab Space
6. View of the mauve vinyl cove base and associated mas�c designated as Homogeneous Area 7 in the report. No asbestos was detected in the cove base or the associated mas�c.
5. View of the grey vinyl cove base and associated mas�c designated as Homogeneous Area 6 in the report. No asbestos was detected in the cove base or the associated mas�c.
Department of Veteran’s Affairs Project 652-22-200 McGuire VAMC-Renovate Radia!on Oncology Lab Space
8. View of the brown vinyl cove base and associated mas�c designated as Homogeneous Area 9 in the report. No asbestos was detected in the cove base or the associated mas�c.
7. View of the green/teal vinyl cove base and associated mas�c designated as Homogeneous Area 8 in the report. No asbestos was detected in the cove base or the associated mas�c.
Department of Veteran’s Affairs Project 652-22-200 McGuire VAMC-Renovate Radia!on Oncology Lab Space
10. View of a sink for which the material that has been applied to the underside would not be considered suspect to contain asbestos and as such the material was not sampled for tes�ng.
9. View of the wall backing material (inside the baggie) that was located behind some areas finished with vinyl cove base. No asbestos was detected in the fabric-like material.
Department of Veteran’s Affairs Project 652-22-200 McGuire VAMC-Renovate Radia!on Oncology Lab Space
12. View of the spray-applied fireproofing applied to the ceiling decking in the inters��al space above Level 2. No asbestos was detected in the material.
11. View of a sink condensate barrier designated as Homogeneous Area 11. No asbestos was detected in the material.
Department of Veteran’s Affairs Project 652-22-200 McGuire VAMC-Renovate Radia!on Oncology Lab Space
14. View of the gray caulking designated as Homogeneous Area 15 that has been applied to seams and other areas of the HVAC components. No asbestos was detected in the material.
13. View of the white caulking designated as Homogeneous Area 14 that has been applied to seams and other areas of the pipe thermal
-system insula�on jacke�ng. No asbestos was detected in the material. The pipe insula�on is fiberglass and not suspect for asbestos.
Department of Veteran’s Affairs Project 652-22-200 McGuire VAMC-Renovate Radia!on Oncology Lab Space
16. View of a pipe insula�on support made of metal-o4en supports at hanging brackets are composed of a material that can poten�ally contain asbestos.
15. View of the tan caulking designated as Homogeneous Area 16 used at various connec�ons of the HVAC system. No asbestos was detected in the material.
Department of Veteran’s Affairs Project 652-22-200 McGuire VAMC-Renovate Radia!on Oncology Lab Space
18. Cap�on
17. Cap�on
Department of Veteran’s Affairs Project 652-22-200 McGuire VAMC-Renovate Radia!on Oncology Lab Space
19. View of a cemen��ous material designated as Homogeneous Area 17 and applied to horizontal support beams in the inters��al area above Level 2. No asbestos was detected in the material.
20. View of 2’ X 2’ lay-in-ceiling �les designated as Homogeneous Area 18 in the report. No asbestos was detected in the ceiling �les.
Department of Veteran’s Affairs Project 652-22-200 McGuire VAMC-Renovate Radia!on Oncology Lab Space
22. View of the ceramic �le and associated grout designated as Homogeneous Area 20 typical of the restrooms in the Oncology area.
No asbestos was detected in the material.
21. View of the gypsum wallboard system designated as Homogeneous Area 19 in the report. Above the lay-in-ceiling view reveals that the joint compound has been applied to taped seams and mechanical fasteners only.
Department of Veteran’s Affairs Project 652-22-200 McGuire VAMC-Renovate Radia!on Oncology Lab Space
24. View of the 12” X 12” vinyl composite floor �le and associated mas�c designated as Homogeneous Area 22 and residual brown cove base mas�c designated as Homogeneous Area 23. Asbestos was not detected in either of the materials.
23. View of an atypical style of 2’ X 2’ lay-in-ceiling �le designated as Homogeneous Area 21. No asbestos was detected in the ceiling
�les which are composed of gypsum with a paper backing.
�ĞƉĂƌƚŵĞŶƚ�ŽĨ�sĞƚĞƌĂŶ͛Ɛ��īĂŝƌƐ�WƌŽũĞĐƚ�ϲϱϮ-ϮϮ-ϮϬϬ� DĐ'ƵŝƌĞ�s�D�-ZĞŶŽǀĂƚĞ�ZĂĚŝĂƟŽŶ�KŶĐŽůŽŐLJ�>Ăď�^ƉĂĐĞ
Ϯϲ͘�sŝĞǁ�ŽĨ�Ă�ĮƌĞ�ƌĂƚĞĚ�ĚŽŽƌ�ĨƌĂŵĞ�Ăƚ�ϭ�-ϭϭϬ͘
Ϯϱ͘�sŝĞǁ�ŽĨ�Ă�ůĂďĞůĞĚ�ĮƌĞ�ĚŽŽƌ�Ăƚ�ZŽŽŵ�ϭ�-ϭϭϬ͘
| 2022-03-29T13:20:17-0400 | |
| CIH Glenn Hargrove | |
| I am the author of this document |
| 2022-03-29T13:25:19-0400 | |
| Samuel D. Bedinger | |
| I am the author of this document |
File details come from the government source that posted it. Updated .