S06 Attachment I - Initial Drawing Package Reformatted.pdf

PDF 21 MB Posted

Attached to
N045--Upgrade HVAC Phase V Federal contract opportunity
Solicitation number
36C24622B0008
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6

About this file

This file is an attachment to a federal contract solicitation for HVAC upgrade services. The solicitation number is 36C24622B0008 and is being issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6 for HVAC upgrade work at Phase V locations. The solicitation seeks contractors to provide HVAC upgrade and maintenance services and the attachment contains initial drawing packages of the locations and systems requiring work. Responses are due based on the standard solicitation timeline and the agency intends to award a firm-fixed price contract for the work outlined.

View the file

Other files for this federal contract opportunity

Other files attached to N045--Upgrade HVAC Phase V, newest first.
File Type Posted
S06 OF 1419 Certified Bid Abstract - HVAC Phase V.pdf PDF
36C24622B0008 0004.docx DOCX document
36C24622B0008 0003.docx DOCX document
36C24622B0008 0002.docx DOCX document
S06 36C24622B0008 Attachment II Questions and Answers.xlsx XLSX spreadsheet
S06 637-19-102 HVAC Ph 5 31 Mar 2022 Site Visit Attendees Sign In Sheet.pdf PDF
36C24622B0008 0001.docx DOCX document
S02 Attachment VI Statement of Requirements 25 Mar 2022.pdf PDF
S02 Attachment IV - Bid Item Cost Breakdown WS.xlsx XLSX spreadsheet
S02 Attachment III - Wage Det NC20220043 25 Feb 2022.pdf PDF
S02 Attachment II - Drawing Package.pdf PDF
36C24622B0008.docx DOCX document
S02 Attachment V - Campus Map.pdf PDF
S02 Attachment I - Specification Package.pdf PDF
Show all 14

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1 2 3 4 5

D C

B A

D C

B A

1 2 3 4 5 6

6" th re e in ch es o ne fo ot

6" th re e qu ar te rs in ch o ne fo ot

6" on e in ch o ne fo ot on e an d on e ha lf in ch es o ne fo ot on e ha lf in ch o ne fo ot

6" th re e ei gh th s in ch o ne fo ot on e ei gh th in ch o ne fo ot on e qu ar te r i nc h on e fo ot

PROJECT NUMBER

BUILDING NUMBER

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

APPROVED

FULLY SPRINKLERED

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

U.S. Department of Veterans Affairs

PHASEARCHITECT/ENGINEER OF RECORD

A/E:

STAMP

HARRELL DESIGN GROUP PC

8016 TOWER POINT DRIVE

CHARLOTTE, NC 28227

704-814-1346 POC: LEE HARRELL PE, LEED AP, QCxP

PRESIDENT

COPYRIGHT © 2021

WWW.HARRELLDG.COM

637-19-102

APRIL 16, 2021

HDG PROJECT: 19037Revision Number Revisions: Date:

CHARLES GEORGE VA MEDICAL CENTER

UPGRADE HVAC, B-47 PHASE 5CONSTRUCTION

DOCUMENTS 100%

H D E S I G N G R O U P , P C

ARRE L L

GI001

COVER SHEET

INDEX OF DRAWINGS

DRAWING NO. TITLE

GI001

NOT TO SCALE

RICEVILLE RD.

VICINITY MAP

COVER SHEET

UT

LENN RD .

R D .

MT N .

ALB

KC

L B

E U

D

R I

EG

Y

K P

CHIEF OF STAFF,

ASSOCIATE DIRECTOR,

INFECTION CONTROL COORDINATOR,

SAFETY MANAGER,

M & O FOREMAN,

AFGE,

APPROVED:

APPROVED:

APPROVED:

APPROVED:

APPROVED:

REVIEWED:

Rice vil le Roa d

Tunnel Road (HWY 70)

N

MD101 FIRST FLOOR DEMOLITION PLAN

MD102

MH101 FIRST FLOOR DUCT PLAN

MH102 SECOND FLOOR DUCT PLAN

MH103 ROOF PLAN

MH104 ROOF PLAN

MH301 MECHANICAL ROOM FLOOR PLAN

MH302 MECHANICAL ROOM FLOOR PLAN

MP101

MP102

MH501 DETAILS

MH502 DETAILS

SECOND FLOOR DEMOLITION PLAN

MH001 LEGENDS, ABBREVIATIONS AND GENERAL NOTES

MH503

MH504

DETAILS

DETAILS

MH601 SCHEDULES

EG001 LEGENDS, GENERAL NOTES, AND SCHEDULES

EE101 FIRST FLOOR ELECTRICAL PLAN

EE102 SECOND FLOOR ELECTRICAL PLAN

EE103 ELECTRICAL ROOF PLAN

EE501 ELECTRICAL DETAILS

EE701 PANEL BOARD SCHEDULES

EE601 BLDG #47 RISER DIAGRAM

EE702

FIRST FLOOR PIPING PLAN

SECOND FLOOR PIPING PLAN

MI701 CONTROLS SCHEMATICS

MI702 CONTROLS SCHEMATICS AND POINTS

MP103 OVERALL FIRST FLOOR PIPING PLAN

AE402 ROOF DETAILS

AE401 DETAILS

AE106 ROOF PLAN

AE105 SECOND FLOOR PLAN

AE104 FIRST AND SECOND FLOOR PLANS

AE103 FIRST FLOOR PLANS

AE101 BASEMENT BOILER ROOM FLOOR PLAN

FA100 GENERAL NOTES AND LEGENDS

FP100 BASEMENT FIRE PROTECTION PLANS

FP101 FIRST FLOOR FIRE PROTECTION PLAN

FP102 SECOND FLOOR FIRE PROTECTION PLAN

EE100 BASEMENT ELECTRICAL PLAN

EE502 ELECTRICAL DETAILS

EE602 ACA EXPANSION RISER DIAGRAM

PANEL BOARD SCHEDULES

AE403 ROOF DETAILS

AE107 ROOF PLAN

FA103 ROOF FIRE ALARM PLAN

FP001 FIRE PROTECTION GENERAL NOTES, SYMBOLS, LEGENDS & DETAILS

Jonathan M. Carr, AIA, NCARB, CDT

2021.04.21 21:28:18 -04'00'

PROJECT LIMITS

PR

O

JE

C

T

LI

M

IT

S

PR

O

JE

C

T

LI

M

IT

S

6' -2

"5' -0

1' -2

" 7' -2

1'-6 1/4"

6'-0" 2'-0" 1'-9"

BF152

BOILER ROOM

FMS

SERVICE DRIVE

COVERED LOADING DOCK

2'-4 1/4"

2'-0" 2'-10 3/4" 4'-0"

2' -4

1 2 3 4 5

D C

B A

D C

B A

1 2 3 4 5 6

6" th re e in ch es o ne fo ot

6" th re e qu ar te rs in ch o ne fo ot

6" on e in ch o ne fo ot on e an d on e ha lf in ch es o ne fo ot on e ha lf in ch o ne fo ot

6" th re e ei gh th s in ch o ne fo ot on e ei gh th in ch o ne fo ot on e qu ar te r i nc h on e fo ot

PROJECT NUMBER

BUILDING NUMBER

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

APPROVED

FULLY SPRINKLERED

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

U.S. Department of Veterans Affairs

PHASEARCHITECT/ENGINEER OF RECORD

A/E:

STAMP

HARRELL DESIGN GROUP PC

8016 TOWER POINT DRIVE

CHARLOTTE, NC 28227

704-814-1346 POC: LEE HARRELL PE, LEED AP, QCxP

PRESIDENT

COPYRIGHT © 2021

WWW.HARRELLDG.COM

637-19-102

APRIL , 2021

HDG PROJECT: 19037Revision Number Revisions: Date:

CHARLES GEORGE VA MEDICAL CENTER

UPGRADE HVAC, B-47 PHASE 5CONSTRUCTION

DOCUMENTS %

H D E S I G N G R O U P , P C

ARRE L L

AE101

BASEMENT BOILER ROOM

FLOOR PLAN

C1

AE101

GG

2 2

1 6" HIGH CONCRETE MECHANICAL EQUIPMENT PAD. SEE D4/AE401 FOR

PAD ANCHOR DETAIL.

2 EQUIPMENT - SEE MECHANICAL DRAWINGS

2 2

1 2 3

R

Q

P

NOT IN PROJECT SCOPE

2021.04.21 20:14:07 -04'00'

10 1D163

CORRIDOR

1G107A

AUD EXAM

SURGERY

N/A

FIRE UTIL

FMS

1G106

ENT EXAM

SURGERY

1G105

ENT EXAM

SURGERY

1G104

ENT EXAM

SURGERY

1G103

ENT EXAM

SURGERY

1D170

CORRIDOR

1G116A

BOOTH

AUDIO

PR

O

JE

C

T

LI

M

IT

S

PROJECT LIMITS

PROJECT LIMITS

PROOJECT L MI STS

NN

FF

AA

RERE UTUT

FMFM

ILIL

SS

1G1G

AA

UDUD

SS

7A E

UR

XA

GE

MM

RYRY

1D1D

COCO

RRRRRIDOROR

TST

IMM

T L

T

ECECE

O J

O J

O

PRPRP

PROJECT LIMITMITSS

1G1GG11G11

BB

6A6A

OOOO

AA

THTH

DUD OO

PR

O

JE

C

T

LI

M

IT

S

PROJECT LIMITS

PROJECT LIMITS

1C118

HAC

MINOR SURG

1C109

TLT

MINOR SURG

1C110

CONTROL

MINOR SURG

1C119

CONTROL

MINOR SURG

1C122

TLT

MINOR SURG

STAIR#3

1C113 D.R.

MINOR SURG

1C112

OFFICE

MINOR SURG

C1

CO

MI

C R S

PROJECT LIMITS

PR

O

JE

C

T

LI

M

IT

S

1C

M

OF

MIN

FIC

OR

E

SURG

1C1

MIN

D.R

OR SURG

PROJECT LIMMITS

1C

M

C1

CO

MI

TS

MM

I

NT

NO

NT

NO

T

MIN

T

MIN

LL

TT

RO

R S

RO

R S

LT

OR

LT

OR

ECEC

L U

L U

SS

O J

RG

UR

PR

G 1C1

CO

MI

NT

NO

RO

R S L

UR

ST

RG

AIR#R#

1C1

MI

HA

NO

C

R S C

R SURG

C

M

C

M

T

NO

T

OR SURGRG

PROJECT LIMITS

PR

O

JE

C

T

LI

M

IT

S

PROJECT LIMITS

PR

O

JE

C

T

LI

M

IT

S

1C169

TLT

MINOR SURG

1C168

DRESS RM

MINOR SURG

S

MI

M

M

1C152

EXAM

MINOR SURG

1C166

SPD

MINOR SURG

1C160A

TOILET

MINOR SURG

1C160

STAFF LOCKER

MINOR SURG

1H159

OFFICE

PROSTHETICS

1H160

OFFICE

PROSTHETICS

1H161

OFFICE

PROSTHETICS

1H153

STORAGE

PROSTHETICS

1C156

MINOR PRO

MINOR SURG

1C154

VASCULAR

MINOR SURG

1C157

EXAM RM

MINOR SURG

1H1

O P

FF

RO

C

ST

S

HE

C

TA

FF

MI

LO

O

CK

R S

ER

URG

FF

RO

C

STHETICS

T M

1H1

O P

FF

RO

CE

STHETIC

1C

S

M

SP

NO

R R

M

SURG

SS

M

C152

EX

MIN

AM

OR S

M

UR

PR

O

JE

C

T

LI

M

IT

S

PROJECT LIMITS

PROJECT LIMITS

PR

O

JE

C

T

LI

M

IT

S

PPROROJEJE

CTCT

H1

O P

H1

O P

LILI

FF

RO

FF

RO

MITMIT

C

ST

C

ST

SS

SS

HEHE

C

TA

C

TA

TICTIC

FF

MIN

FF

MIN

SS

LO

O

LO

O

CK

R S

CK

R S

ER

UR

ER

URGG

11H1

O P

H1

O P

FF

RO

FF

RO

CE

ST

CE

ST

SS

HEHE

ITIT

TICTIC

LI

M

LI

M

SS

C T

C T

JEJE

R

O R

O

PP

1C1C16

T M

T M

0A

OI

IN

ET

OR SURG

GG

H1

O

PR

H1

O

PR

FF

RO

FF

RO

CE

ST

CE

STHEHETICTIC

1C1C

SS

M

SP

NO

D R

D

R SUSURGRG

1H1H

TS

ST

PR

ST

PR

M

OR

OS

OR

OS

T L

AG

TH

AG

TH

C1

EC

E

ET

E

ET

T

MIN

O J

ICIC

LT

OR

PR

SS

SURG

1C

D

RE

M

SS

NO

R R

M

SURG

SS

M

S

MMIMIII

PROJECTCT LIMLIMMITMITSS

C1C152

EX

MIN

EX

MIN

AM

OR

AM

OR S

MM

URUR

M

G

M

PR

O

JE

C

T

LI

M

IT

S

PROJECT LIMITS

PROJECT LIMITS

PR

O

JE

C

T

LI

M

IT

S

4' -0

4'

-2

ALIGN NEW

PAD WITH

EXISTING

1D166

SWITCHGEAR

FMS

1 2 3 4 5

D C

B A

D C

B A

1 2 3 4 5 6

6" th re e in ch es o ne fo ot

6" th re e qu ar te rs in ch o ne fo ot

6" on e in ch o ne fo ot on e an d on e ha lf in ch es o ne fo ot on e ha lf in ch o ne fo ot

6" th re e ei gh th s in ch o ne fo ot on e ei gh th in ch o ne fo ot on e qu ar te r i nc h on e fo ot

PROJECT NUMBER

BUILDING NUMBER

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

APPROVED

FULLY SPRINKLERED

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

U.S. Department of Veterans Affairs

PHASEARCHITECT/ENGINEER OF RECORD

A/E:

STAMP

HARRELL DESIGN GROUP PC

8016 TOWER POINT DRIVE

CHARLOTTE, NC 28227

704-814-1346 POC: LEE HARRELL PE, LEED AP, QCxP

PRESIDENT

COPYRIGHT © 2021

WWW.HARRELLDG.COM

637-19-102

APRIL , 2021

HDG PROJECT: 19037Revision Number Revisions: Date:

CHARLES GEORGE VA MEDICAL CENTER

UPGRADE HVAC, B-47 PHASE 5CONSTRUCTION

DOCUMENTS %

H D E S I G N G R O U P , P C

ARRE L L

11 12 13 14 15 16 17 18 19 2015 16 17 18 19

D

C

B

A

20876

H

G

F

E

D

C

B

9 10

J

8 9 10

L

K

J

14 15 16 17

C

131211109874321

EXISTING SERVICE DRIVE

AREAWAY

V.9

5.63.9

S.9

U.2

P

M

JN

O

Q

R

AM

BU

LA

TO

R Y

C

AR

E

EN

TR

AN

C E

M

EC

H C

H

AS

E #1

M

EC

H C

H

AS

E #2

M

EC

H C

H

AS

E #4

M

EC

H C

H

AS

E #3

M

EC

H C

H

AS

E #5

MECH CHASE

#1

MECH CHASE

#6

PATIENT VISITOR ENTRANCE

CARDIO / PULMONARY

IMAGING

WARD 1-EAST

PHARMACY

In -p at ie nt P ha rm ac y

A cc es s

EN

T

AU

D

IO

LO

G Y

MINOR SURGERY

D/W

REF

A

DN

MEZZANINE

STATION

N U

R

SE

S

ST

AT

IO

N

STATION

STATION

STATION

STATION

STATION

STATION

STATION

STATION

STATION

STATION

1K141B

STORE ROOM

HAS

1G100A

OFFICE

CHAPLAIN

1D113A

RADIOGRAHIC

IMAGING

1A179

MALE TLT

FMS

1E124

CORRIDOR

1E115

CORRIDOR

1E121

NUTRITION

ONCOLOGY

1E115

CORRIDOR

1E115

CORRIDOR

1E126

DIRTY RM

ONCOLOGY

1E110

CORRIDOR

1E111

INFUSION CENTER

ONCOLOGY

1E103

TLT

ONCOLOGY

1E104

TLT

ONCOLOGY

1E122

TLT

ONCOLOGY

1E117

WAITING

ONCOLOGY/PALLIATIVE

1E100

CLERKS

ONCOLOGY

1E101

OFFICE

ONCOLOGY

1E102

OFFICE

ONCOLOGY

1E105

EXAM

ONCOLOGY

1E106

EXAM

ONCOLOGY

1E107

EXAM

ONCOLOGY

1E108

EXAM

ONCOLOGY

1E109

EXAM

ONCOLOGY

1W101B

TOILET

FMS

1W101A

TOILET

FMS

1A101D

TELE

1A161A

CLEAN ROOM

MINOR SURGERY

1A173A

OFFICE

PODIATRY

BF127

WAREHOUSE

BMS

1A100

VESTIBULE

1A127

VEST

HAS

1A130

PHARM

1B101

WAITING

PRIME CARE

1B111A

EXAM

PRIME CARE

1B112A

EXAM

PRIME CARE

1D102

WAITING

IMAGING

1K100

WAITTING

CARD/PLMNRY

1K110

EXAM

CARD/PLMNRY

1K141A

STORE ROOM

CANTEEN

1K142

OFFICE

PAT ADVOCATE

1K143

OFFICE

PAT ADVOCATE

1J100

WAITTING

PRIME CARE

1C120A

EXAM ROOM

MINOR SURG

1F126A

OFFICE

PHARM

1F127

OFFICE

PHARM

1H119

EXAM

PMRS

1D131

CHAPLAIN

SOCIAL WORKS

1D132

SOCIAL WORKER

SOCIAL WORKS

1F114

IRM

DATA CLT

1F120

HAC

1F137

CACI

PHARM

1D141

ULTRASOUND

IMAGING

1W156

HALL

1W153

CORRIDOR

1W151

CORRIDOR

1W132

TOILET

FMS

1W124

TOILET

FMS

1W116

TOILET

FMS

1W108

TOILET

FMS

1W154

CORRIDOR

1W153

HALL

1W121A

RN

PRIME CARE

1W121

MD

PRIME CARE

1W102

CLERKS STN

PRIME CARE

1W137

HAC

FMS

1W136

SOIL

PRIME CARE

1W152

CORRIDOR

1W103

LEAD CLERK

PRIME CARE

1W101

WAITING RM

PRIME CARE

1W104

EXAM

PRIME CARE

1W105

EXAM

PRIME CARE

1W107

PHARM D

PHARM

1W110

RN

PRIME CARE

1W109

RN

PRIME CARE

1W111

NURSE MGR

PRIME CARE

1W115

MD

PRIME CARE

1W117

RN

PRIME CARE

1W120

RN

PRIME CARE

1W113

FA CL

FMS

1W114

MD

PRIME CARE

1W118

RN

PRIME CARE

1W119

MD

PRIME CARE

1W123

ANEMIA

PRIME CARE

1W122

PHARM D

PHARM

1W126

PHARM D

PHARM

1W125

PHARM D

PHARM

1W127

RN

PRIME CARE

1W128

MD

PRIME CARE

1W150

CLEAN

PRIME CARE

1W149

MD

PRIME CARE

1W148

MD

PRIME CARE

1W147

ELEC CL

FMS

1W145

RN

PRIME CARE

1W144

ID

PRIME CARE

1W143

RN CLST

PRIME CARE

1W142

RN CLST

PRIME CARE

1W141

TOILET

FMS

1W140

RN CLST

PRIME CARE

1W139

DIET

PRIME CARE

1W135

DATA

OI&T

1W134

CONF/TEACH

PRIME CARE

1W129

RN

PRIME CARE

1W138

STAFF LOUNGE

PRIME CARE

1W133

EDUC

PRIME CARE

1W130

PA

PRIME CARE

1W131

MD

PRIME CARE

1H113A 1G131

PMRS

1D139

IRM

DATA CLOSET

1D108

DRESSING RM

IMAGING1D106

WAITING

IMAGING

1D109

OFFICE

IMAGING

1J204

CLST

PRIME CARE

1J206

NURSE STN

PRIME CARE

1J205A

TLT

FMS

1J209A

TLT

FMS

1A238

CORRIDOR

ED

1A229

LOBBY/VEND

ED

1A231

MALE

ED

1A232

WAITING

ED

1A232

WAITING

ED

1A228

RECEPTION

ED

1A234

EXAM

ED

1A227

NURSE STN #2

ED

1A237

CORRIDOR

ED

1A214

MED

ED

1A240B

ALCOVE #3

ED

1A239A

ALCOVE #1

ED

1A240A

ALCOVE #2

ED

1A239

CORRIDOR

ED

1A241

CORRIDOR

ED

1A213

MED

ED

1A240

CORRIDOR

ED

1A200

NURSE STN #1

ED

1A217

RAD

ED

1A230

FEMALE

ED

1A236

CORRIDOR

ED1A208A

ANTE RM

ED

1A212

STAFF

ED

1A201

OBS 1

ED

1A202

OBS 2

ED

1A203

OBS 3

ED

1A204

OBS 4

ED

1A205

OBS 5

ED

1A206

OBS 6

ED

1A207

OBS 7

ED

1A208

OBS 8

ED

1A209

OBS 9

ED

1A210

OBS 10

ED

1A211

OBS 11

ED

1A220

HAC

FMS

1H125

RECEPTION

PMRS

1H131

EXAM

PMRS

1G132

OFFICE

OTHER

1G131

EXAM/OFFICE

OTHER

1G130

EXAM/OFFICE

OTHER

1G129

EXAM/OFFICE

OTHER1G137

WAITING

OTHER

1G125

EXAM/OFFICE

OTHER

1G127

EXAM/OFFICE

OTHER

1G126

EXAM/OFFICE

OTHER

1G124

EXAM/OFFICE

OTHER

1G128

SPINAL CORD INJURY

PMRS

1H113B

STORAGE

PMRS

1D143

MEDICAL SUPPLIES

IMAGING

1H117

WAITING

PMRS

1H139

EXAM

PMRS

1H138

EXAM

PMRS

1H136

OFFICE

PMRS

1H132

BATH

PMRS

1H127

WORK AREA

PMRS

1H129

KITCHEN

PMRS

1H126

WORK STM

PMRS

1H128

BREAK ROOM

PMRS

1H130

EXAM

PMRS

1H133

EXAM

PMRS

1H149

1H135

CK-IN

PMRS

1H140

WAITING

PMRS

1E135A

STORAGE

PMRS

1H142

OFFICE

PMRS

1H141

OFFICE

PMRS

1H144

OFFICE

PMRS

1H118

EXAM

PMRS

1H118A

STORAGE

PMRS

1H122A

RECEPTION

PMRS

1H122

OFFICE

PMRS

1H121

OFFICE

PMRS

1H120

OFFICE

PMRS

1H123

OFFICE

PMRS

1H124

OFFICE

PMRS

1H143

OFFICE

PMRS

1H116

EXAM

PMRS

1H115

EXAM

PMRS

1H112

OFFICE

CHAPLIN

1H111

OFFICE

CHAPLIN

1F107

OFFICE

PHARM

1F108

OFFICE

PHARM

1F105

STORAGE

PHARM

1F130

CONF RM

PHARM

1C156

MINOR PRO

MINOR SURG 1C169

TLT

MINOR SURG

1C168

DRESS RM

MINOR SURG

1C170

SOIL UTIL

MINOR SURG

1C171

EXAM

MINOR SURG

1C147

EXAM

MINOR SURG

1C148

EXAM

MINOR SURG

1C152

EXAM

MINOR SURG

1C154

VASCULAR

MINOR SURG

1C150

BREAK ROOM

MINOR SURG

1C149

STORAGE

MINOR SURG

1C144

MEDS

MINOR SURG

1C104

RECEPT

MINOR SURG

1C142

HAC

FMS

1C129

EXAM-17

MINOR SURG

1C132

STORAGE

MINOR SURG

1C134

EXAM-16

MINOR SURG

1C137

EXAM-15

MINOR SURG

1C138

EXAM-14

MINOR SURG

1C140

EXAM-13

MINOR SURG

1C139

EXAM-12

MINOR SURG

1C135

EXAM-11

MINOR SURG

1C133

EXAM-10

MINOR SURG

1C130

EXAM-9

MINOR SURG

1C128

EXAM-8

MINOR SURG

1C127

EXAM-7

MINOR SURG

1C125

EXAM-6

MINOR SURG

1C122

SOILED UTIL

MINOR SURG

1C117

URODYNAMICS

MINOR SURG

1C116

BIOPSY RM

MINOR SURG

1C107

EXAM-2

MINOR SURG1C

PR

IN

T

RO

OM

M

IN

OR

S

UR

G

1C106

EXAM-1

MINOR SURG

1C123

EXAM-5

MINOR SURG

1C118

HAC

MINOR SURG

1C109

TLT

MINOR SURG

1C110

CONTROL

MINOR SURG

1C119

CONTROL

MINOR SURG

1C122

TLT

MINOR SURG

1C120

CAST RM

MINOR SURG

STAIR#3

1C119

CYSTO

MINOR SURG1C113

D.R.

MINOR SURG

1C112

OFFICE

MINOR SURG

1C1681C167

1C102

RECEPT

MINOR SURG

1C101

WAITING

MINOR SURG1C166

SPD

MINOR SURG

1C160A

TOILET

MINOR SURG

1C157

EXAM RM

MINOR SURG

1C160

STAFF LOCKER

MINOR SURG

1G136

FML TLT

FMS

1D160

RADIOGRAPHIC RM

IMAGING

1D159

RADIOGRAPHIC RM

IMAGING

1D158

OFFICE

IMAGING

1D162A

TLT

IMAGING

1D162

DESSING RM

IMAGING1D157

STORE ROOM

IMAGING

1D161

RADIOGRAPHIC RM 1

IMAGING

1D163

RADIOGRAPHIC RM 2

IMAGING

1D156

OFFICE

IMAGING

1D164

FLUORO RM 3

IMAGING1D155

OFFICE

IMAGING

1D154

C/T TA CTL

IMAGING

1D171

TECH IMAGING WORK ROOM

IMAGING

1D165C

STORAGE

IMAGING

1D165B

TLT

IMAGING

1D165A

TLT

IMAGING

1D165

DRESS RM

IMAGING

1D153

C/T TA SCAN

IMAGING

1D166

FLUOROSCOPIC RM 4

IMAGING

1D152

STORAGE

IMAGING

1G1O9

AUD EXAM

SURGERY

1G110

AUD EXAM

SURGERY

1G100B

CPE RESIDENTS

CHAPLAIN

1G100

MAIN CHAPEL

CHAPLAIN

1D152B

ELEC UTIL

FMS

1D152A

PHONE UTIL

FMS

1G108A

HC TLT

AUDIO

1G108

AUD INSTR CALIB

SURGERY

1D163

CORRIDOR

1G107A

AUD EXAM

SURGERY

1G107B

AUD EXAM

SURGERY

1D174

ELEC UTIL

FMS

N/A

FIRE UTIL

FMS

1G106A

TLT

SURGERY

1G105A

TLT

SURGERY

1G106

ENT EXAM

SURGERY

1G105

ENT EXAM

SURGERY

1G104

ENT EXAM

SURGERY

1G118

CONTROL

AUDIO

1G118A

BOOTH

AUDIO

1G103

ENT EXAM

SURGERY

1D

CO

RR

ID

OR

1G117A

BOOTH

AUDIO

1G116A

BOOTH

AUDIO

1G117

CONTROL

AUDIO

1G116

CONTROL

AUDIO

1G111

AUD EXAM

SURGERY

1G112

AUD EXAM

SURGERY

1G113

AUD EXAM

SURGERY

1G114

AUD EXAM

SURGERY

1D

CO

RR

ID

OR

1G115

AUD OFFICE

SURGERY

1G102

AUDIO RECEPTION

SURGERY

1G101

AUDIO WAITING

SURGERY

1H110

OFFICE

CHAPLIN

1G135

MAILE TLT

FMS

1G119

ENT EXAM

SURGERY

1G120

ENT EXAM

SURGERY

1G121

ENT EXAM

SURGERY

1G122

ENT EXAM

SURGERY

1D141

CORRIDOR

1D118

CORRIDOR

1G134

EQUIP STORE

PMRS

TG133D

ELECT UTIL

FMS

TG133C

PHONE UTIL

FMS

TG133B

ELEC UTIL

FMS

TG133A

HAC

FMS

1G131

STORAGE

PMRS

1G123

EXAM/OFFICE

OTHER

1H113

KITCHEN

PMRS

1H114

EXAM

PMRS

N/A

FIRE UTIL

FMS

N/A

FIRE UTIL

FMS

1H156

CHIEF

PROSTHETICS

1H158

STORAGE

PROSTHETICS

1H159

OFFICE

PROSTHETICS

1C

CO

RR

ID

OR

1H160

OFFICE

PROSTHETICS1H152

OFFICE

PROSTHETICS

1H155

BREAK ROOM

PROSTHETICS 1H161

OFFICE

PROSTHETICS

1H154

OFFICE

PHROSTHETICS

1H151

OFFICE

PROSTHETICS

1H150

WAITING

PROSTHETICS

1H153

STORAGE

PROSTHETICS

1H157

LAB

PROSTHETICS

STR #5

1H148

MALE TLT

FMS

1H147

FML TLT

FMS

1F129

OFFICE

PHARM

1F111

MED PREP

PHARM

1F125

CLINIC PHARM

PHARM

1F126

OFFICE

PHARM

1F128

CONF RM

PHARM

1F121

OFFICE

PHARM

1F122

OFFICE

PHARM

1F123

OFFICE

PHARM

1F124

BREAK ROOM

PHARM

1B

CO

RR

ID

OR

1C126

CORRIDOR

1F104

WINDOWS

PHARM

1F101

WAITING

PHARM

1F103

RECEPTION

PHARM

1F102

RESEARCH ROOM

PHARM

1F113

VAULT

PHARM

1F109

MED PREP

PHARM

1F117

TECH OFFICE

PHARM

1F119

RO CLOSET

1F138

SUPPLY

PHARM

1F139

CASE MGR

PSYCH

1H140A

ELEC EQUIP

FMS

1H146

HAC

FMS

1H145

TLT

FMS

TA137B

ELEC EQUIP

FMS

TA137C

FIRE EQUIP

FMS

TA137A

ELEC EQUIP

FMS

1E120

HAC

FMS

STR #4

1E113

STAFF BREAK ROOM

ONCOLOGY

1E114

EXAM ROOM

PALLATIVE CARE

1E116

OFFICE

N&FS1E114A

TLT

PALL CARE

1E123

TLT

ONCOLOGY

1E116A

TLT

N&FS

1E117A

TLT

ONCOLOGY

1E129

OFFICE

PALLATIVE CARE

1E128

EXAM / TRMT

PALLATIVE CARE

1E127

OFFICE

ONCOLOGY

1E113A

TLT

ONCOLOGY

1E123A

FIRE UTIL

FMS

1E113C

PHONE UTIL

FMS

1E113B

FIRE UTIL

FMS

1E112

ELECT UTIL

FMS

1E125

CLEAN RM

ONCOLOGY

1E119

TRIAGE

ONCOLOGY

1E118

CLERK

PALL CARE

1B193

CORRIDOR

1B

CO

RR

ID

OR

1F131

SOILED LINEN

FMS

1F132

TRASH

FMS

1F134

CLERK

PHARM

1F133

DEC AFFS

HAS

1F136

ELECT UTIL

FMS

1F135

CART STOR

N&FS

ST

R

TA101C

ELEC UTIL

FMS

STR #1

1D103

TOILET

FMS

1B

CO

RR

ID

OR

1K125

WORK ROOM

CARD/PLMNRY

1K144

ELECT

FMS

1K

HA

C

FM

S

1K121

OFFICE

CARD/PLMNRY

1K120

OFFICE

CARD/PLMNRY

1K119

CLEAN UTILITY

CARD/PLMNRY

1K118

EXAM

CARD/PLMNRY

1B189

ELECT

FMS

1K114

OFFICE

CARD/PLMNRY

1K113

OFFICE

CARD/PLMNRY

1K109

EXAM

CARD/PLMNRY

1K117

EXAM

CARD/PLMNRY

1K122

EXAM

CARD/PLMNRY

1K124

EQ/GAS STORE

CARD/PLMNRY

1B187

CORRIDOR

1K129

OFFICE

CARD/PLMNRY

1K132

ECHO

CARD/PLMNRY

1K126

EXAM

CARD/PLMNRY

1K127

EXAM

CARD/PLMNRY

1K116

EXAM

CARD/PLMNRY

1K115

EXAM

CARD/PLMNRY

1K112

EXAM

CARD/PLMNRY

1K111

EXAM

CARD/PLMNRY

1K128

BREAK ROOM

CARD/PLMNRY

1K

6A

TL

T/

DR

ES

S

CA

RD

/P

LM

NR

Y

1B

CO

RR

ID

OR

1B

CO

RR

ID

OR

1K130

EXAM

CARD/PLMNRY

1K131

EXAM

CARD/PLMNRY

1B216

CORRIDOR

1K108

EXAM

CARD/PLMNRY

1K133

EXAM

CARD/PLMNRY

1K134

EKG

CARD/PLMNRY

1K105

RECEPT

CARD/PLMNRY

1K107

OFFICE

CARD/PLMNRY

1K106

SUB-WAIT

CARD/PLMNRY

1K141

VENDING

CANTEEN

1K138

OFFICE

FISCAL

1K137

CASHIER

FISCAL

1K140

WAITING

FISCAL

1K104

CONSULT

CARD/PLMNRY1K103

WATING

CARD/PLMNRY

1K135

EXAM

CARD/PLMNRY

1K136

STRESS TEST

CARD/PLMNRY

1K136A

OFFICE

CARD/PLMNRY

1K136B

STORAGE

CARD/PLMNRY 1K139

TRAVEL CK

FISCAL1K101

FML TLT

FMS

1D130B

TOILET

FMS

1D128A

MRI COMPUTER RM

IMAGING

1D130A

TOILET

FMS

1D

M

RI

C

ON

TR

OL

IM

AG

IN

G

1D130

MRI 2 COMPUTER RM

IMAGING

1D129

MRI 2 SCANNER

IMAGING

1D127

MRI SCANNER

IMAGING

1D101

TOILET

FMS

1D105

RECEPT / WAITTING

IMAGING

1D104

CONF RM

IMAGING

1D113

RADIOGRAHIC

IMAGING

1D107

OFFICE

IMAGING

1D124

OFFICE

IMAGING

1D125

OFFICE

IMAGING

1D126

BREAK RM

IMAGING1D

IV

C

ON

SE

NT

IM

AG

IN

G

1D118

NUC MED CAMERA 1

IMAGING

1D116A

DECAY CLOSET

IMAGING

1D116

RADIO PHARMACY

IMAGING

1D115

DOSE ADMIN

IMAGING

1D122

CORRIDOR

1D117

TOILET

IMAGING

1D119

NUC MED CAMERA 2

IMAGING

1D120

NUC MED CAMERA 3

IMAGING

1D121

NM READ / PROC

IMAGING

1D141A

TLT

IMAGING

1D123

LOCKERS

IMAGING

1D111

ELEC EQUIP

FMS

1D135

CORRIDOR

1D112

HAC

FMS

1D122

UPTAKE ROOM

IMAGING

1D114

STAFF LOUNGE

IMAGING

1D

CO

RR

ID

OR

1D169

DIV / ANGIO

IMAGING

1D170

DVI CONTROL

IMAGING

1D167

C/T PQ SCANNER

IMAGING

1D151

PHYSICIAN

IMAGING

1D168

C/T CONTROL

IMAGING

1D132

ELEC

FMS

1D131

ELEC EQUIP

FMS

1D133

FIRE EQUIP

FMS

1D148

CORRIDOR

TD149

ELEC EQUIP

FMS

N/A

FIRE EQUIP

FMS

1D150

OFFICE

IMAGING

1D148

OFFICE

IMAGING

1D147

OFFICE

IMAGING

1D146

OFFICE

IMAGING

1D145

RADIOLOGIST

IMAGING

1D142

ULTRASOUND

IMAGING

1D144

COMP ROOM

FMS

1D138

OFFICE

IMAGING

1D140

UTIL

IMAGING

1D137

OFFICE

IMAGING

1D136

OFFICE

IMAGING

1D135

OFFICE

IMAGING

1D134

OFFICE

IMAGING

1B163

NS

PRIME CR

1B166

SOIL UTL

PRIME CR

1B165

CLEAN UTL

PRIME CR

1B167

HC TLT

FMS

1B

CO

RR

ID

OR

1B

CO

RR

ID

OR

1B161

BREAK ROOM

PRIME CARE

1B162

HAC

FMS

1B168

EXAM

PRIME CARE

1B174

OFFICE

EXEC

1B175

OFFICE

EXEC

1B177

VESTIBULE

EXEC

1B176

OFFICE

EXEC

1B173

OPTICAL

SHOP

TC158D

EC

FMS

TC158A

EC

FMS

TC158C

EC

FMS

1J113

EXAM

PRIME CARE

1J112

EXAM

PRIME CARE

1D133

NURSE

NURSING

1J111

EXAM

PRIME CARE

1J110

EXAM

PRIME CARE

1D134

CHIEF NURSE

EXEC OFFICE

1J118B

EXAM

PRIME CARE

TC158B

PHONE

FMS

1J118A

EXAM

PRIME CARE

C1C6

CORRIDOR

C 1C

CO

RR

ID

OR

C 1C

CO

RR

ID

OR

1J106

HAS SUPER

HAS

1J105

EXAM

PRIME CARE

1J115

CLEAN UTIL

PRIME CARE

1J118C

EXAM

PRIME CARE

1J116

MED RM

PRIME CARE

1J114

NURSES STATION

PRIME CARE

1J117

STAFF TLT

FMS

1J108

MALE TLT

FMS

1J107

FML TLT

FMS1J104

RECEPTION

PRIME CARE

1J103

WAITTING

PRIME CARE

1J101

FML TLT

FMS

1A168

OFFICE

CPAC

1A169

OFFICE

CPAC

1J201

CONF ROOM

PRIME CARE1J200

WAITING ROOM

PRIME CARE

1J202

RECEPTION

PRIME CARE

1J205

EXAM

PRIME CARE

1J207

OFFICE

PRIME CARE

1J208

OFFICE

PRIME CARE

1J203

OFFICE

PRIME CARE

1J209

EXAM

PRIME CARE

1J109

BREAK ROOM

PRIME CARE

1J210

EXAM/PROCEDURE

PRIME CARE

1J142

EXAM RM

PRIME CARE

1J142A

TLT

FMS

1J210A

TLT

FMS

1D166

SWITCHGEAR

FMS

1D167

ELECTRICAL

FMS

1J126

SOILD UTL

FMS

1J141

EXAM

PRIME CARE

1J140

EXAM RM

PRIME CARE

1J136

EXAM RM

PRIME CARE

1J133

EXAM RM

PRIME CARE

1J135

EXAM RM

PRIME CARE

1J134

EXAM RM

PRIME CARE1J119

EXAM RM

PRIME CARE

1J120

EXAM RM

PRIME CARE

1J128

EXAM RM

PRIME CARE

1J127

EXAM

PRIME CARE

1J121

EXAM RM

PRIME CARE

1J139

EXAM RM

PRIME CARE

C 1C

CO

RR

ID

OR

C 1C

CO

RR

ID

OR

C 1C

CO

RR

ID

OR

1J137

EXAM RM

PRIME CARE

1J132

EXAM RM

PRIME CARE

1J129

EXAM RM

PRIME CARE

1J124

EXAM RM

PRIME CARE

1J122

EXAM RM

PRIME CARE

1J125

EXAM RM

PRIME CARE

C 1C

CO

RR

ID

OR

1J143A

TLT

FMS

1J143

EXAM

PRIME CARE

C1C1

CORRIDOR

1J138

EXAM

PRIME CARE

1J131

EXAM

PRIME CARE

1J130

EXAM

PRIME CARE

1J123

EXAM

PRIME CARE

1J157

PHY EXTEND

PRIME CARE

1J146

PHYSICIAN

PRIME CARE

1J158

HAC

FMS

1J156

PHYSICIAN

PRIME CARE

1J155

PHYSICIAN

PRIME CARE

1J154

PHYSICIAN

PRIME CARE

1J153

PHYSICIAN

PRIME CARE

1J152

PHYSICIAN

PRIME CARE

1J151

PHYSICIAN

PRIME CARE

1J150

PHYSICIAN

PRIME CARE

1J149

PHYSICIAN

PRIME CARE

1J148

AA ACOS

PRIME CARE 1J145

VESTIBULE

FMS

1J147

PHYSICIAN

PRIME CARE

1A163

SIGNAL

FMS

1A162

ELECTRICAL

FMS

1A170

OFFICE

PODIATRY

1A171

OFFICE

PODIATRY

1A167

OFFICE

PODIATRY1A172

OFFICE

PODIATRY

1A166

OFFICE

PODIATRY

1A165

RECEPTIONIST

MH

1A173

OFFICE

PODIATRY

1A215

STOR/SWING SPACE

ED

1A216

CLEAN

LINEN

1A222

NURSE MGR

ED

1J144

CHIEF

ED

1A218A

SAFE

ACS-ER

1A221

TLT/SHOWER

ACS-ER

1A219

SOILED LINEN

ED

1A218

BREAK ROOM

ED

1B184

VESTIBULE

1B144

OFFICE

PRIME CARE

1B145

OFFICE

PRIME CARE

1B146

OFFICE

PRIME CARE

1B147

OFFICE

PRIME CARE

1B148

OFFICE

PATIENT ADVOCATE

1B150

OFFICE

PRIME CARE

1B151

OFFICE

PRIME CARE

1B152

OFFICE

PRIME CARE

1B153

OFFICE

PRIME CARE

1B154

OFFICE

PRIME CARE

1B155

EXAM

PRIME CARE

1B156

EXAM

PRIME CARE

1B157

EXAM

PRIME CARE

1B158

EXAM

PRIME CARE

1B160

EXAM

PRIME CARE

1B149

OFFICE

PRIME CARE

1B159

EXAM

PRIME CARE

1B

CO

RR

ID

OR

1B171

CORRIDOR

1B142

OFFICE

PRIME CARE

1B141

OFFICE

PRIME CARE

1B140

WORK ROOM

PRIME CARE

1B138

OFFICE

PRIME CARE

1B136

WORK ROOM

PRIME CARE

1B143

OFFICE

PRIME CARE

1B130

OFFICE

PRIME CARE

1B129

OFFICE

PRIME CARE

1B131

OFFICE

PRIME CARE

1B128

OFFICE

PRIME CARE

1B127

MED STORE

PRIME CARE

1B134

SIGNAL

FMS

1B135

ELECTRICAL

FMS

1B180

CORRIDOR

1B126

EXAM #7

PRIME CARE

1B164

ASSESS

PRIME CARE

1B111

EXAM

PRIME CARE1B110

EXAM #2

PRIME CARE

1B114

EXAM #15

PRIME CARE

1B109

EXAM #1

PRIME CARE

1B112

EXAM

PRIME CARE

1B116

EXAM #13

PRIME CARE

1B117

EXAM #12

PRIME CARE

1B118

EXAM #11

PRIME CARE

1B119

EXAM #10

PRIME CARE

1B120

EXAM #9

PRIME CARE

1B121

EXAM #8

PRIME CARE

1B125

EXAM #6

PRIME CARE

1B113

EXAM #3

PRIME CARE

1B124

EXAM #5

PRIME CARE

1B115

EXAM #14

PRIME CARE

1B123

HC TLT

PRIME CARE

1B122

EXAM #4

PRIME CARE

1B124

CORRIDOR

STR #2

1B107

CORRIDOR

1B169

OFFICE

HAS

1B102

RECEPT/CONTROL

HAS

1B107

EXAM ROOM

PRIME CARE

1B106

EXAM ROOM

PRIME CARE

1B104

EXAM ROOM

PRIME CARE

1B105

EXAM ROOM

PRIME CARE

1B103

EXAM

TELEHEALTH

1B107A

HC TLT

PRIME CARE

1B108

WORK ROOM

PRIME CARE

1A161

CORRIDOR

1A161

EXAM ROOM

PODIATRY

1A160

EXAM ROOM

PODIATRY

1A

CO

RR

ID

OR

1A171

PATIENT SAFETY

COS

1A

CO

RR

ID

OR

1A108A

RECEPT

HAS

1A106

ELEV LOBBY

1A107

CORRIDOR

1A105

CORRIDOR

1A113

WAITING

1A102

GALLERY

ACS-PRIM CARE

1A104

GALLERY

CANTEEN

1A103

LOBBY

1A101

VESTIBULE

1A121

CORRIDOR

1A123

OFFICE

GERI-PACT

1A122

OFFICE

GERI/PACT

1A124

MALE HC TLT

EMS

1A125

AOD

HAS

1A149

CORRIDOR

1A146

OFFICE

PRE-OP

1A147

OFFICE

PRE-OP

1A148

OFFICE

PRE-OP

1A126

OFFICE

PRE-OP

1A145

OFFICE

PRE-OP

1A144

OFFICE

PRE-OP

1A143

OFFICE

PRE-OP

1A142

OFFICE

PRE-OP

1A109

HC TLT

EMS

1A110A

OFFICE

VOLUNTARY

1A111

OFFICE

GERI/PACT

1A112

CONF ROOM

GERI/PACT

1A113

EXAM

GERI/PACT

1A114

SUPPLY

GERI/PACT

1A115

EXAM

GERI/PACT

1A116

EXAM

GERI/PACT

1A117

EXAM

GERI/PACT

1A

CO

RR

ID

OR

1A118

EXAM

GERI/PACT

1A119

HAC

FMS

1A139

OFFICE

TELEHEALTH

1A140

OFFICE

TELEHEALTH

1A141

OFFICE

TELEHEALTH

1A150

CORRIDOR

1A131

OFFICE

TELEHEALTH

1A132

OFFICE

TELEHEALTH

1A133

OFFICE

TELEHEALTH

1A134

OFFICE

TELEHEALTH

1A223

HC TLT/SHOWER

ED

1A224

EXAM/SECURITY

ED

1A225

EXAM

ED

1A226

LIFE SUPPORT

ED

1A233

VEST

ED

1A235

VEST

ED

1A135

SOCIAL WORK

GERI/PACT

STR #11A137

SIGNAL

FMS

1A136

ELECTRICAL

FMS

PRIMARY CARE 1

ELEV. #1

ELEV. #2

ELEV. #?

ELEV. #?

ELEV. #?EL

EV

EL

EV

1W106

STICK (POC)

PRIME CARE

1W155

HALL

1W146

MD

PRIME CARE

CARDO/PLMNRY

PO

DI

AT

RY

W

OM

EN

'S

H

EA

LT

H

ELEV. #3

PRIMARY CARE 3

PROCESSING

ENTRANCE

EMERGENCY

21 22 23 24 25 26

G

H

J

K

L

M

N

O

P

Q

R

S

26252423

22212019

T

U

V

7.4

5 6

NO WORK EXCEPT BRINGING DUCT INTO CEILING OF 1A112

AE103

FIRST FLOOR PLANS

1 2

N

11 12

K

L

7 8

J

K

O

P

11 12 13 14 15 16 17 18 19 2015 16 17 18 19

D

C

B

A

20876

H

G

F

E

D

C

B

9 10

J

8 9 10

L

K

J

14 15 16 17

C

131211109874321

EXISTING SERVICE DRIVE

AREAWAY

V.9

5.63.9

S.9

U.2

P

M

N

O

Q

R

REF

A

DN

ELEV. #1

ELEV. #2

ELEV. #3

21 22 23 24 25 26

G

H

J

K

L

M

N

O

P

Q

R

S

26252423

22212019

T

U

V

7.4

5 6

D3

AE103

C2

AE103

C1

AE103

GG

A. xx

M

D4

AE103

5.6 7.4

V.9

U.2

S.9

1. 14" HIGH CONCRETE ELECTRICAL EQUIPMENT PAD. SEE D3/AE401 FOR

PAD ANCHOR DETAIL.

2. REMOVE EXISTING GRID AND TILES TO INSTALL NEW DUCT. REINSTALL

CEILING GRID AND TILES, REPLACING ANY DAMAGED OR MISMATCHED

TILES OR CEILING GRID.

2 2

NOT IN PROJECT SCOPE

2021.04.21 20:14:36 -04'00'

2A250

LAB

2B256

OFFICE

2B251B

STOR.

2B257

2B258

CATH

STAFF

TOILET

2A251A

STOR.

2A252

SURG.

OPER. 2

2A229

LOCKER ROOM

2A201B

DENTAL REC

2A202

MALE

HC TOILET

2A203

FEMALE

HC TOILET

CHASE #2

1A151

CORRIDOR

1A121

CORRIDOR

1A123

OFFICE

GERI-PACT

1A122

OFFICE

GERI/PACT

1A124

MALE HC TLT

EMS

1A125

AOD

HAS

1A109

HC TLT

EMS

1A110A

OFFICE

VOLUNTARY

1A111

OFFICE

GERI/PACT

1A112

CONF ROOM

GERI/PACT

1A113

EXAM

GERI/PACT

1A114

SUPPLY

GERI/PACT

1A115

EXAM

GERI/PACT

C

A1 O

RR DOR

1A 212

AAOD

HAS

1A

MA

LE

HC

E T

MS

LT

1A

A O

G

HC

FF

E

TL

EM

C

RI-

T S

EE

APACTCT

1A

C

O

RR DOR

1 0A0A

FFFF

OLOL

CECE

UNUNTARY

A O

FF

GE

IC

RI/

E

PACT

A

G

EX

ER

AM

RI/PACT

G

A1A S

G

UPPLPL

I/PRI/P C

YY

ACAC

T C

A1

ON

G

F

ER

PROJECT LIMITS

PROJECT LIMITS

E

1A121

CORRIDOR

1A123

OFFICE

GERI-PACT

1A122

OFFICE

GERI/PACT

1A124

MALE HC TLT

EMS

1A125

AOD

HAS

1A109

HC TLT

EMS

1A110A

OFFICE

VOLUNTARY

1A111

OFFICE

GERI/PACT

1A112

CONF ROOM

GERI/PACT

1A113

EXAM

GERI/PACT

1A114

SUPPLY

GERI/PACT

1A115

EXAM

GERI/PACT

1A1A122

AAODDODD

HAHHAH SSSS

1A11A1

MAMMAMA

12121212

LELELELE

HCHHCH

EEEE

C TTC TT

MSMSMSMS

LTLTLTLT

1A1A1A1A

AAAA

OOOO

GG

00090

HCHCHCHC

23232323

FFFFFFFF

GEEGEE

TLTLTLTL

EMEMEMEM

CCCC

RI-RIRI-RI

TT

SSSS

EE

PAACTT

1A11A1

CC

12121212

OOOO

RRRRRRRR DODODODORRRR

1111A1A1

OO

VV

0A0

FFF

OOLOL

CCECE

UUNUNTAATAARYRYRYRY

1AAAA

OO

2222222

FFFFFFFF

GEGEGEGE

ICICICIC

RI/RI/RI/RI/

EE

PAACTT

AAAA

GG

15151515

EXEXEXEX

EEEE

AMAMAMAM

RI/PRI/PRI/PRI/PACAACA TTTT

G

A1A

SS

G

14141414

UPPUPUP

ERERERER

P

PLL

RI/PI/P C

RO

Y

ACA

JE

TT

TCT

A1A

OO

GG

LIMLIML

FFF

ERER

MIT

CECE

I/PI/P

S

P

ACAC

RORO

TTTT

JE TCT LIMMITS

CC

A1A

ONON

GG

F

ERER

RORO

I/PI/P

OMOM

ACACTT

AAAA

GG

13131313

EXEXEXEX

EEEE

AMAM

RI/PRI/PACA TT

PROJECT LIMITS

PROJECT LIMITS

DEMO EXISTING CEILING AT NEW PARTITION.

REPAIR CEILING AT NEW PARTITION.

MTL RUNNER TRACK

UNDERSIDE OF STRUCTURE

16 GAUGE 4" MTL STUDS, 16" O.C. MAX

MTL RUNNER TRACK

STOP GWB 5/8" ABOVE FLOOR.

INSTALL CONTINUOUS SEALANT

5/8" GWB ON ONE SIDE OF 4" MTL STUDS.

5/8" GWB ONE SIDE (TYPE X)

EXISTING FLOOR SLAB

16 GAUGE 4" MTL STUDS, 16" O.C. MAX

NEW RUBBER BASE TO MATCH EXISTING

PAINT GWB TO MATCH EXISTING. FINISH GWB

TO LEVEL 5 FINISH.

PROVIDE FRAMING

FOR ACCESS PANELS

PAINT EXISTING CEILING IF HARD CEILING. CUT AND MODIFY ACT

CEILING AND INSTALL NEW WALL MOULDING ON NEW WALL.

2A251A

STOR.

NEW DUCT CHASE

1 2 3 4 5

D C

B A

D C

B A

1 2 3 4 5 6

6" th re e in ch es o ne fo ot

6" th re e qu ar te rs in ch o ne fo ot

6" on e in ch o ne fo ot on e an d on e ha lf in ch es o ne fo ot on e ha lf in ch o ne fo ot

6" th re e ei gh th s in ch o ne fo ot on e ei gh th in ch o ne fo ot on e qu ar te r i nc h on e fo ot

PROJECT NUMBER

BUILDING NUMBER

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

APPROVED

FULLY SPRINKLERED

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

U.S. Department of Veterans Affairs

PHASEARCHITECT/ENGINEER OF RECORD

A/E:

STAMP

HARRELL DESIGN GROUP PC

8016 TOWER POINT DRIVE

CHARLOTTE, NC 28227

704-814-1346 POC: LEE HARRELL PE, LEED AP, QCxP

PRESIDENT

COPYRIGHT © 2021

WWW.HARRELLDG.COM

637-19-102

APRIL , 2021

HDG PROJECT: 19037Revision Number Revisions: Date:

CHARLES GEORGE VA MEDICAL CENTER

UPGRADE HVAC, B-47 PHASE 5CONSTRUCTION

DOCUMENTS %

H D E S I G N G R O U P , P C

ARRE L L

AE104

FIRST AND SECOND FLOOR PLANS

N

O

24 25

N

O

B2

AE104

GG

A. XX

FIRST FLOOR PLAN

SECOND FLOOR PLAN

D2

AE104

1. NEW PARTITION.

2. DEMOLISH EXISTING CEILING AT NEW PARTITION. REPAIR CEILING AT

NEW PARTITION AND PAINT.

3. 24"X24" ACCESS PANEL, MOUNTED 12" ABOVE FLOOR TO BOTTOM OF

PANEL DOOR OPENING. CENTER ON NEW DUCT.

4. NEW DUCT - SEE DRAWING MH103.

5. CLOSE DOORS DURING CONSTRUCTION. PROVIDE CLASS IV ICRA

MEASURES DURING CONSTRUCTION.

6. SAW CUT PORTIONS OF ELEVATED SLAB FOR DUCT PENETRATIONS.

DO NOT CUT THRU BEAMS, JOISTS OR OTHER STRUCTURAL MEMBERS.

ONLY SAW CUT THE ELEVATED SLAB. INSTALL FIRE DAMPER PER

MANUFACTURER REQUIREMENTS.

7. CONTRACTOR MAY ONLY USE THIS ROOM FOR STAGING FOR WORK IN

THIS ROOM.

8. CEILING GRID AND TILE TO BE REMOVED FOR INSTALLATION OF NEW

DUCT. REINSTALL GRID AND TILE AFTER DUCT INSTALLATION IS

COMPLETE.

EXISTING SERVICE DRIVE

AREAWAY

REF

DN

ELEV. #1

ELEV. #2

ELEV. #3

NOT IN PROJECT SCOPE

5 5

DOES NEW PARTITION GET INSTALLED ON TOP

OF EXISTING FLOORING?

2021.04.21 20:15:00 -04'00'

TU

-5

-2

TU-5-2

TU

-5

-1

PROJECT LIMITS

TU

-5

-2

TU-5-2

TU-5-13

TU

-5

-1

STAFF

SUR OFF

2B217

STAFF

SUR OFF

2B214

CLEAN

2B202

ENDO #1

2B203

SOIL

2B201A

CLEAN UP

2B204

ENDO #2

2B205

STORAGE

ROOM

2B210

PHYS.

OFFICE

2B208

OFFICE

2B209

CHANGE

2B206

HC TLT.

2B207

H

AC

2B

NURSE

SUB-STATION

2B201

PROJECT LIMITS

PR

O

JE

C

T

LI

M

IT

S

PR

O

JE

C T

LI

M

IT

S

PR

O

JE

C

T

LI

M

IT

S

PR

O

JE

C T

LI

M

IT

S

PROJECT LIMITS

1 2 3 4 5 6

D C

B A

1 2 3 4 5 6

PROJECT NUMBER

BUILDING NUMBER

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

APPROVED

FULLY SPRINKLERED

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

U.S. Department of Veterans Affairs

PHASEARCHITECT/ENGINEER OF RECORD

A/E:

STAMP

HARRELL DESIGN GROUP PC

8016 TOWER POINT DRIVE

CHARLOTTE, NC 28227

704-814-1346 POC: LEE HARRELL PE, LEED AP, QCxP

PRESIDENT

COPYRIGHT © 2021

WWW.HARRELLDG.COM

637-19-102

APRIL , 2021

HDG PROJECT: 19037Revision Number Revisions: Date:

CHARLES GEORGE VA MEDICAL CENTER

UPGRADE HVAC, B-47 PHASE 5CONSTRUCTION

DOCUMENTS %

H D E S I G N G R O U P , P C

ARRE L L

AE105

SECOND FLOOR PLAN

GG

A. XX

D2

AE105

NOT IN PROJECT SCOPE

1. REMOVE EXISTING GRID AND TILES TO INSTALL NEW DUCT. REINSTALL

CEILING GRID AND TILES, REPLACING ANY DAMAGED OR MISMATCHED

TILES OR CEILING GRID.

2021.04.21 20:15:31 -04'00'

FIRST FLOOR ROOF

H

G

J

L

K

J

P

M

JN

O

FIRST FLOOR ROOF

H

G

J

L

K

J

P

M

JN

O

32 32 74 5 6 74 5 6 12111098 1211109811

1 2 3 4 5

D C

B A

D C

B A

1 2 3 4 5 6

6" th re e in ch es o ne fo ot

6" th re e qu ar te rs in ch o ne fo ot

6" on e in ch o ne fo ot on e an d on e ha lf in ch es o ne fo ot on e ha lf in ch o ne fo ot

6" th re e ei gh th s in ch o ne fo ot on e ei gh th in ch o ne fo ot on e qu ar te r i nc h on e fo ot

PROJECT NUMBER

BUILDING NUMBER

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

APPROVED

FULLY SPRINKLERED

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

U.S. Department of Veterans Affairs

PHASEARCHITECT/ENGINEER OF RECORD

A/E:

STAMP

HARRELL DESIGN GROUP PC

8016 TOWER POINT DRIVE

CHARLOTTE, NC 28227

704-814-1346 POC: LEE HARRELL PE, LEED AP, QCxP

PRESIDENT

COPYRIGHT © 2021

WWW.HARRELLDG.COM

637-19-102

APRIL 16, 2021

HDG PROJECT: 19037Revision Number Revisions: Date:

CHARLES GEORGE VA MEDICAL CENTER

UPGRADE HVAC, B-47 PHASE 5CONSTRUCTION

DOCUMENTS 100%

H D E S I G N G R O U P , P C

ARRE L L

AE106

ROOF PLAN

GG

A. DUCT AND PIPE SIZES SHOWN ON DRAWING INCLUDE DUCT OR PIPE

AND INSULATION.

B. COORDINATE EXACT ROOF OPENING WITH SUBCONTRACTOR AND

COORDINATION DRAWINGS PRIOR TO CUTTING OPENINGS.

1. RE-ROOF THIS AREA. SEE SPECS FOR WORK. RE-ROOF AND REPAIR

EXISTING ROOF IN THIS AREA TO MAINTAIN EXISTING FACTORY

WARRANTY, IF IN EFFECT. REMOVE EXISTING ROOFING AND

INSULATION TO ALLOW NEW CURB TO BE SET.

2. DUCT - SEE MECHANICAL DRAWINGS

3. EQUIPMENT - SEE MECHANICAL DRAWINGS

8-1/2" DIA AND 7" DIA

PIPE

28"X16" DUCT44"X16" DUCT

14"X14" DUCT

12"X12" DUCT

22"X16" DUCT

24"X16" DUCT

FIRST FLOOR ROOF

SECOND FLOOR ROOF

SECOND

FLOOR

ROOF FIRST

FLOOR

ROOF

SIXTH FLOOR ROOF

SIXTH FLOOR ROOF SIXTH FLOOR ROOF

PENTHOUSE ROOF

FIRST

FLOOR

ROOF

FIRST FLOOR ROOF

FIRST FLOOR ROOF

FIRST

FLOOR

ROOF

LOWER

ROOF

FIRST

FLOOR

ROOF

HIGHER

ROOF

11 12 13 14 15 16 17 18 19 2015 16 17 18 19

D

C

B

A

20876

H

G

F

E

D

C

B

9 10

J

8 9 10

L

K

J

14 15 16 17

C

1312111098

V.9

5.63.9

S.9

U.2

P

M

JN

O

Q

R

A

21 22 23 24 25 26

G

H

J

K

L

M

N

O

P

Q

R

S

26252423

T

U

V

7.4

5 6

D1

AE106

2021.04.21 20:15:59 -04'00'

SECOND FLOOR ROOF

SECOND

FLOOR

ROOF

FIRST

FLOOR

ROOF

FIRST

FLOOR

ROOF

G

H

J

K

L

M

N

O

P

SECOND FLOOR ROOF

SECOND

FLOOR

ROOF

FIRST

FLOOR

ROOF

FIRST

FLOOR

ROOF

G

H

J

K

L

M

N

O

P

16 17 18 1916 17 18 19 2120 2120 2222 26252423 26252423

1 2 3 4 5

D C

B A

D C

B A

1 2 3 4 5 6

6" th re e in ch es o ne fo ot

6" th re e qu ar te rs in ch o ne fo ot

6" on e in ch o ne fo ot on e an d on e ha lf in ch es o ne fo ot on e ha lf in ch o ne fo ot

6" th re e ei gh th s in ch o ne fo ot on e ei gh th in ch o ne fo ot on e qu ar te r i nc h on e fo ot

PROJECT NUMBER

BUILDING NUMBER

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

APPROVED

FULLY SPRINKLERED

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

U.S. Department of Veterans Affairs

PHASEARCHITECT/ENGINEER OF RECORD

A/E:

STAMP

HARRELL DESIGN GROUP PC

8016 TOWER POINT DRIVE

CHARLOTTE, NC 28227

704-814-1346 POC: LEE HARRELL PE, LEED AP, QCxP

PRESIDENT

COPYRIGHT © 2021

WWW.HARRELLDG.COM

637-19-102

APRIL 16, 2021

HDG PROJECT: 19037Revision Number Revisions: Date:

CHARLES GEORGE VA MEDICAL CENTER

UPGRADE HVAC, B-47 PHASE 5CONSTRUCTION

DOCUMENTS 100%

H D E S I G N G R O U P , P C

ARRE L L

AE107

ROOF PLAN

GG

20"X20" DUCT

18"X18" DUCT

9" PIPE AND 7-1/4" PIPE

46"X20" DUCT

38"X20" DUCT

1. RE-ROOF THIS AREA. SEE SPECS FOR WORK. RE-ROOF AND REPAIR

EXISTING ROOF IN THIS AREA TO MAINTAIN EXISTING FACTORY

WARRANTY, IF IN EFFECT. REMOVE EXISTING ROOFING AND

INSULATION TO ALLOW NEW CURB TO BE SET.

2. DUCT - SEE MECHANICAL DRAWINGS

3. EQUIPMENT - SEE MECHANICAL DRAWINGS

FIRST FLOOR ROOF

SECOND FLOOR ROOF

SECOND

FLOOR

ROOF FIRST

FLOOR

ROOF

SIXTH FLOOR ROOF

SIXTH FLOOR ROOF SIXTH FLOOR ROOF

PENTHOUSE ROOF

FIRST

FLOOR

ROOF

FIRST FLOOR ROOF

FIRST FLOOR ROOF

FIRST

FLOOR

ROOF

LOWER

ROOF

FIRST

FLOOR

ROOF

HIGHER

ROOF

11 12 13 14 15 16 17 18 19 2015 16 17 18 19

D

C

B

A

20876

H

G

F

E

D

C

B

9 10

J

8 9 10

L

K

J

14 15 16 17

C

1312111098

V.9

5.63.9

S.9

U.2

P

M

JN

O

Q

R

A

21 22 23 24 25 26

G

H

J

K

L

M

N

O

P

Q

R

S

26252423

T

U

V

7.4

5 6

D1

AE107

A. DUCT AND PIPE SIZES SHOWN ON DRAWING INCLUDE DUCT OR PIPE

AND INSULATION.

B. COORDINATE EXACT ROOF OPENING WITH SUBCONTRACTOR AND

COORDINATION DRAWINGS PRIOR TO CUTTING OPENINGS.

2021.04.21 20:16:29 -04'00'

PAINT CHAMFER

FEDERAL SAFETY

YELLOW

CONCRETE EQUIPMENT PAD,

WITH #3@10" OC EACH WAY AT

MID-DEPTH; ALL OTHER PADS

UP TO 12" THICK WITH #4@12"

OC EACH WAY AT MID-DEPTH

FLOOR SLAB, SEE

STRUCTURAL DRAWINGS FOR

TYPE

#4 DOWEL ANCHORS EPOXIED

INTO FLOOR EVERY 16" OC MAX

TOP OF PAD TO

BE PLUMB AND

LEVEL

PAINT CHAMFER

FEDERAL SAFETY

YELLOW

CONCRETE EQUIPMENT PAD,

WITH #3@10" OC EACH WAY AT

MID-DEPTH; ALL OTHER PADS

UP TO 12" THICK WITH #4@12"

OC EACH WAY AT MID-DEPTH

FLOOR SLAB, SEE

STRUCTURAL DRAWINGS FOR

TYPE

#4 DOWEL ANCHORS EPOXIED

INTO FLOOR EVERY 16" OC MAX

TOP OF PAD TO

BE PLUMB AND

LEVEL

1 2 3 4 5

D C

B A

D C

B A

1 2 3 4 5 6

6" th re e in ch es o ne fo ot

6" th re e qu ar te rs in ch o ne fo ot

6" on e in ch o ne fo ot on e an d on e ha lf in ch es o ne fo ot on e ha lf in ch o ne fo ot

6" th re e ei gh th s in ch o ne fo ot on e ei gh th in ch o ne fo ot on e qu ar te r i nc h on e fo ot

PROJECT NUMBER

BUILDING NUMBER

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

APPROVED

FULLY SPRINKLERED

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

U.S. Department of Veterans Affairs

PHASEARCHITECT/ENGINEER OF RECORD

A/E:

STAMP

HARRELL DESIGN GROUP PC

8016 TOWER POINT DRIVE

CHARLOTTE, NC 28227

704-814-1346 POC: LEE HARRELL PE, LEED AP, QCxP

PRESIDENT

COPYRIGHT © 2021

WWW.HARRELLDG.COM

637-19-102

APRIL 16, 2021

HDG PROJECT: 19037Revision Number Revisions: Date:

CHARLES GEORGE VA MEDICAL CENTER

UPGRADE HVAC, B-47 PHASE 5CONSTRUCTION

DOCUMENTS 100%

H D E S I G N G R O U P , P C

ARRE L L

AE401

DETAILS

GG

1 XX

CUT EDGE SEALANT

TPO CUSTOM

CURB FLASHING

TPO MEMBRANE

2" MIN. HAND WELD AT JOINING LAP OF CURB

FLASHING (TYP.)

CURB

CUT EDGE SEALANT

VERTICAL T-JOINT COVER - TYP.

FLASHING MEMBRANE

RAISED CURB

RIGID INSULATION

COUNTERFLASHING

TREATED WOOD NAILER

1'' MINIMUM BELOW TOP OF CURB

SEALING MATERIAL - MUST BE CONTINUOUS ON TOP OF THE

CURB

BASE OF UNIT EXTENDS 1/2'' MINIMUM BEYOND TOP OF CURB

MECHANICAL UNIT, HOOD, ETC.

PRESSURE TREATED

WOOD NAILER

SEALING MATERIAL

SEAM PLATES

AND FASTENERS

ROOF INSULATION

FLASHING

MEMBRANE

REMOVABLE SHEET METAL

COUNTERFLASHING

GASKETED

FASTENERS

PREMANUFACTURED

RAISED CURB

FLASHING DETAIL

CURB SECTION

FULLY ADHERED TPO

ROOFING SYSTEMWOOD NAILERS AND

CANT STRIP

COVER BOARD

COMPOSITE SLAB

CURB ISOMETRIC

B4

MH504

A6

MH504

C6

MH504B4

MH504

Jonathan M. Carr, AIA, NCARB, CDT

2021.04.21 20:16:57 -04'00'

C

B A

D C

B A

1 2 3 4 5 6

6" th re e in ch es o ne fo ot

6" th re e qu ar te rs in ch o ne fo ot

6" on e in ch o ne fo ot on e an d on e ha lf in ch es o ne fo ot on e ha lf in ch o ne fo ot

6" th re e ei gh th s in ch o ne fo ot on e ei gh th in ch o ne fo ot on e qu ar te r i nc h on e fo ot

PROJECT NUMBER

BUILDING NUMBER

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

APPROVED

FULLY SPRINKLERED

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

U.S. Department of Veterans Affairs

PHASEARCHITECT/ENGINEER OF RECORD

A/E:

STAMP

HARRELL DESIGN GROUP PC

8016 TOWER POINT DRIVE

CHARLOTTE, NC 28227

704-814-1346 POC: LEE HARRELL PE, LEED AP, QCxP

PRESIDENT

COPYRIGHT © 2021

WWW.HARRELLDG.COM

637-19-102

APRIL 16, 2021

HDG PROJECT: 19037Revision Number Revisions: Date:

CHARLES GEORGE VA MEDICAL CENTER

UPGRADE HVAC, B-47 PHASE 5CONSTRUCTION

DOCUMENTS 100%

H D E S I G N G R O U P , P C

ARRE L L

AE402

ROOF DETAILS

GG

SUBSTRATE

TPO MEMBRANE

INSULATION

WELDED SPLICE

2" (51 mm) MIN. 1/

2"

1" (1 m m m m

R O

U N

D P

EN

ET

R

AT

IO

N

SUBSTRATE

INSULATION

8" (2 m m ) M

IN

ACCEPTABLE BONDING ADHESIVE

STAINLESS STEEL CLAMPING RING NOTE:

1. REMOVE ALL EXISTING FLASHING, LEAD, ETC.

PIPE SURFACE MUST BE FREE OF ALL RUST,

GREASE, INSULATION, ETC.

3. PIPE MUST BE ANCHORED TO ENSURE

STABILITY.

4. NO WRINKLES OR FOLDS PERMITTED UNDER

CLAMPING RING.

5. DO NOT USE WHEN SERVICE LINE TEMP.

EXCEEDS 160 °F. REFER TO UT- P-6 & UT-P-7.

6. ACCEPTABLE BONDING ADHESIVE REQUIRED

BETWEEN MEMBRANE AND INSULATION FOR

ADHERED SYSTEMS.

ACCEPTABLE BONDING

ADHESIVE (SEE NOTE #6)

FIRESTONE FASTENER AND HD OR HD PLUS SEAM PLATE @

12" (305 mm) O.C. MAX.

TPO FLASHING (UNSUPPORTED) OR TPO

MEMBRANE AS FLASHING

TPO MEMBRANE AS FLASHING

CONTINUOUS BEAD OF AP SEALANT

SUBSTRATE

INSULATION

SUBSTRATE

PE

N

ET

R

AT

IO

N (H

O T

ST

AC

K)

1/2

1" (1

3 m m

- 2 5 m m)

WELDED SPLICE

2" (51 mm) MIN.

8" (2 m m ) M

IN

INSULATION

TPO MEMBRANE

ACCEPTABLE BONDING ADHESIVE

NOTES:

1. REMOVE ALL EXISTING FLASHING, LEAD, ETC.

PIPE SURFACE MUST BE FREE OF ALL RUST,

GREASE, INSULATION, ETC.

3. PIPE MUST BE ANCHORED TO ENSURE STABILITY.

4. NO WRINKLES OR FOLDS UNDER CLAMPING RING.

5. ACCEPTABLE BONDING ADHESIVE REQUIRED

BETWEEN MEMBRANE AND INSULATION FOR

ADHERED SYSTEMS.

6. FASTENER AND HD SEAM PLATE REQUIRE FOR MAS

ONLY.

7. WHEN REINFORCEMENT OF TPO MEMBRANE IS

EXPOSED, CUT EDGE SEALANT APPLICATION.

ACCEPTABLE BONDING ADHESIVE

FASTENER AND SEAM PLATE @

12" (305 mm) O.C. MAX. (SEE NOTE #6)

TPO FLASHING (UNSUPPORTED) OR TPO

MEMBRANE AS FLASHING

TPO FLASHING (UNSUPPORTED)

CONTINUOUS BEAD OF

TEMPERATURE OR HIGH GRADE

SEALANT

FIELD FABRICATED METAL HOOD BY OTHERS

(REQUIRED)

INSULATED METAL SLEEVE BY

OTHERS

CONTINUOUS BEAD OF

FIRESTONE AP SEALANT

STAINLESS STEEL CLAMPING

RING

FASTENER AND SEAM PLATE

AT 12" (300 mm) O.C. MAX.

WELDED SPLICE 2" (50 mm) MIN.

TPO CUSTOM PIPE BOOT

ULTRAPLY TPO MEMBRANE

T-JOINT PATCH AT BASE FLASHING OVERLAP (SEE

NOTE #5)

CUT EDGE SEALANT (SEE NOTE #8)

8" (2 m m ) M

IN

WELDED SPLICE 2" (50 mm) MIN.

(SPLIT BOOT ONLY)

CONTINUOUS BEAD OF

TPO SEALANT

NOTE:

1. REMOVE ALL EXISTING FLASHING, LEAD, ETC.

PIPE SURFACE MUST BE FREE OF ALL RUST, GREASE, INSULATION, ETC.

2. PENETRATION MUST BE ANCHORED TO ENSURE STABILITY.

4. DO NOT USE WHEN SERVICE LINE TEMP. EXCEEDS 160 °F. REFER TO UT-P-6 &

UT-P-7.

5. T-JOINT PATCH REQUIRED AT SEAM OVERLAP AND VERTICAL TRANSITION.

6. FASTENER AND HD SEAM PLATE REQUIRE FOR MAS ONLY.

7. APPLY CUT EDGE SEALANT TO ANY EDGES WHERE SCRIM REINFORCEMENT IS

EXPOSED.

8. BONDING ADHESIVE REQUIRED UNDER CUSTOM PIPE BOOT VERTICAL

FLASHING.

9. ACCEPTABLE PRIMER REQUIRED UNDER FLASHING.

5.5" TPO FLASHING OR 6" FLASHING

T-JOINT PATCH AT VERTICAL TRANSITION (SEE

NOTE #5)

A. HOT DIP GALVANIZE NEW TEMPORARY STEEL.

B. CUT HOLES IN EXISTING ROOF TO INSTALL NEW POSTS

FOR UNIT FRAMES. AFTER DISMANTLING TEMPORARY

STEEL, REPAIR ROOF.

Jonathan M. Carr, AIA, NCARB, CDT

2021.04.21 20:17:25 -04'00'

CL

CONCRETE PANEL

3" ALUMINUM PANEL

DO NOT DISTURB CONTINUOUS

EXISTING REGLET

REMOVE ALUMINUM PANELS AT DUCT

PENETRATIONS. MODIFY / CUT

EXISTING PANELS TO CONFORM TO

ROUGH OPENING SIZE

NEW DUCT / INSULATION /

JACKET PENETRATING

PENTHOUSE EXTERIOR WALL

CONTINUOUS SEALANT BEAD

INSTALL CONTINUOUS BACKER

ROD & SEALANT ON INSIDE OF

PENTHOUSE

ROUGH OPENING IN CONCRETE

PANEL IS DUCT/ INSULATION /

JACKET DIMENSION PLUS 4"

AFTER REMOVAL OF TEMPORARY

DUCT, INSTALL NEW BLANKED AND

INSULATED LOUVER TO MATCH

EXISTING LOUVERS

1' -0

" M

IN

FILL ANNULAR SPACE WITH

MINERAL WOOL, CONTINUOUS.

6"

INSTALL NEW MATCHING

ALUMINUM DUCT COLLAR AROUND

DUCT. COLLAR TO MATCH

EXISTING ALUMINUM PANELS

ULTRAFL

PROTECT SPRAY FIRE PROOFING

DURING CONSTRUCTION (TYP).

REPAIR WITH 2-HOUR SPRAY IF

DAMAGED (UL P702).

PIPE

NOTES:

1. PRIME ALL NON POROUS SURFACES

WITH FLASHING PRIMER.

2. APPLY BASE AND LIQUID FLASHING PER

MANUFACTURER.

3. OVERLAP NEW AND EXISTING ROOFING

PER MANUFACTURER.

EXISTING ROOF

EXISTING ROOF INSUL.

EXISTING COVERBOARD

BASE FLASHING

LIQUID FLASHING

RO

OF

IN

G

PE

R

MA

NU

F.

RE

CO

MM

EN

DA

TI

ON

S

ROOFING PER MANUF.

RECOMMENDATIONS

REMOVE EXISTING ROOFING AND

SUBSTRATE FOR PENETRATION.

REPLACE W/ SIMILAR MATERIALS.

TOP OF EXISTING STEEL

CAP SHEET W/

GRANULAR COATING

BASE AND PLY SHEETS

COVERBOARD

PROTECT SPRAY FIRE PROOFING

DURING CONSTRUCTION (TYP).

REPAIR WITH 2-HOUR SPRAY IF

DAMAGED (UL P702).

CONTINUOUS FIRE CAULK TO

MAINTAIN ROOF RATING

STEEL TUBE

EXISTING ROOF

EXISTING ROOF INSUL.

EXISTING COVERBOARD

REMOVE EXISTING ROOFING AND

SUBSTRATE FOR PENETRATION.

REPLACE W/ SIMILAR MATERIALS.

TOP OF EXISTING STEEL

CL

BASE FLASHING AND CAP

SHEETS

CAP SHEET W/

GRANULAR COATING

BASE AND PLY SHEETS

1/4" GALV. BOLTS 6" O.C.

FIRE RETARDANT TREATED

WOOD BLOCKING, TYP.

STEEL TUBE

SEE STRUCT. DWGS

NOTES:

1. PRIME ALL NON POROUS SURFACES WITH

FLASHING PRIMER.

2. APPLY BASE AND LIQUID FLASHING PER

MANUFACTURER.

3. OVERLAP NEW AND EXISTING ROOFING PER

MANUFACTURER.

4. WOOD NAILERS MUST BE INSTALLED WITH

SUITABLE FASTENERS TO MEET APPLICABLE

BUILDING CODES (200 LBS PER LINEAR FOOT

MIN IN ANY GIVEN DIRECTION).

RO

OF

IN

G

PE

R

MA

NU

F.

RE

CO

MM

EN

DA

TI

ON

S

ROOFING PER MANUF.

RECOMMENDATIONS

CONT. BEAD OF SEALANT

PROTECT SPRAY FIRE PROOFING

DURING CONSTRUCTION (TYP).

REPAIR WITH 2-HOUR SPRAY IF

DAMAGED (UL P702).

UMBRELLA TYPE POCKET

FLASHING AT EACH TUBE

SECTION PER SMACNA

6TH EDITION, FIG. 4-16B

CANT

COVERBOARD

CONTINUOUS VAPOR

BARRIER MEMBRANE

FILL ANNULAR SPACE W/

MINERAL WOOL

EXISTING ROOF

EXISTING ROOF INSUL.

EXISTING COVERBOARD

REMOVE EXISTING ROOFING AND

SUBSTRATE FOR PENETRATION.

REPLACE W/ SIMILAR MATERIALS.

TOP OF EXISTING STEEL

BASE FLASHING AND CAP

SHEETS

CAP SHEET W/

GRANULAR COATING

BASE AND PLY SHEETS

1/4" GALV. BOLTS 6" O.C.

NOTES:

1. PRIME ALL NON POROUS SURFACES WITH

FLASHING PRIMER.

2. APPLY BASE AND LIQUID FLASHING PER

MANUFACTURER.

3. OVERLAP NEW AND EXISTING ROOFING PER

MANUFACTURER.

4. WOOD NAILERS MUST BE INSTALLED WITH

SUITABLE FASTENERS TO MEET APPLICABLE

BUILDING CODES (200 LBS PER LINEAR FOOT

MIN IN ANY GIVEN DIRECTION).

RO

OF

IN

G

PE

R

MA

NU

F.

RE

CO

MM

EN

DA

TI

ON

S

ROOFING PER MANUF.

RECOMMENDATIONS

UMBRELLA TYPE POCKET

FLASHING AT EACH TUBE

SECTION PER SMACNA

6TH EDITION, FIG. 4-16B

CANT

COVERBOARD

FIRE RETARDANT TREATED

WOOD BLOCKING, TYP.

CONTINUOUS VAPOR

BARRIER MEMBRANE

FILL ANNULAR SPACE W/

MINERAL WOOL

DUCT W/ INSULATED JACKET

SEE MECH. DWGS

CONT. BEAD OF SEALANT

BREAK METAL ANGLE.

SEE STRUCT. DRAWINGS

ROUGH OPENING IN ROOF IS

DUCT/ INSULATION / JACKET

DIMENSION PLUS 4"

CONTINUOUS FIRE CAULK TO

MAINTAIN ROOF RATING

EXISTING ROOF

EXISTING ROOF INSUL.

EXISTING COVERBOARD

REMOVE EXISTING ROOFING AND

SUBSTRATE FOR PENETRATION.

REPLACE W/ SIMILAR MATERIALS.

TOP OF EXISTING STEEL

CAP SHEET W/

GRANULAR COATING

BASE AND PLY SHEETS

NOTES:

1. PRIME ALL NON POROUS SURFACES WITH

FLASHING PRIMER.

2. APPLY BASE AND LIQUID FLASHING PER

MANUFACTURER.

3. OVERLAP NEW AND EXISTING ROOFING PER

MANUFACTURER.

4. WOOD NAILERS MUST BE INSTALLED WITH

SUITABLE FASTENERS TO MEET APPLICABLE

BUILDING CODES (200 LBS PER LINEAR FOOT

MIN IN ANY GIVEN DIRECTION).

COVERBOARD

BREAK METAL ANGLE.

SEE STRUCT. DRAWINGS

CONTINUOUS FIRE CAULK TO

MAINTAIN ROOF RATING

NO

N-

SH

RI

NK

IN

G

GR

OU

T

PE

NE

TR

AT

IO

N

PE

NE

TR

AT

IO

N

BASE FLASHING

LIQUID FLASHING

SHEET METAL PITCH PAN,

SOLDERED/WELDED WATERTIGHT

NON-SHRINK GROUTLIQUID FLASHING (MIN 2") COVERAGE

AROUND PENETRATIONS)

4" MINIMUM FLANGE SET IN LIQUID

FLASHING OVER FIELD PLIES (PRIME

FLANGE WITH PRIMER)

ROOFING PER MANUF.

RECOMMENDATIONS

A. HOT DIP GALVANIZED NEW STEEL.

B. CUT HOLES IN EXISTING ROOF TO INSTALL NEW POSTS

FOR UNIT FRAMES.

1 2 3 4 5

D C

B A

D C

B A

1 2 3 4 5 6

6" th re e in ch es o ne fo ot

6" th re e qu ar te rs in ch o ne fo ot

6" on e in ch o ne fo ot on e an d on e ha lf in ch es o ne fo ot on e ha lf in ch o ne fo ot

6" th re e ei gh th s in ch o ne fo ot on e ei gh th in ch o ne fo ot on e qu ar te r i nc h on e fo ot

PROJECT NUMBER

BUILDING NUMBER

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

APPROVED

FULLY SPRINKLERED

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

U.S. Department of Veterans Affairs

PHASEARCHITECT/ENGINEER OF RECORD

A/E:

STAMP

HARRELL DESIGN GROUP PC

8016 TOWER POINT DRIVE

CHARLOTTE, NC 28227

704-814-1346 POC: LEE HARRELL PE, LEED AP, QCxP

PRESIDENT

COPYRIGHT © 2021

WWW.HARRELLDG.COM

637-19-102

APRIL 16, 2021

HDG PROJECT: 19037Revision Number Revisions: Date:

CHARLES GEORGE VA MEDICAL CENTER

UPGRADE HVAC, B-47 PHASE 5CONSTRUCTION

DOCUMENTS 100%

H D E S I G N G R O U P , P C

ARRE L L

AE403

ROOF DETAILS

2021.04.21 20:17:57 -04'00'

A AMPERE, AMMETER

AF AMPERE FRAME

AFF ABOVE FINISHED FLOOR

AIC AMPERES INTERRUPTING CAPACITY

AT AMPERE TRIP

ATS AUTOMATIC TRANSFER SWITCH

C CONDUIT

CL CENTER LINE

CR CARD READER ACCESS

CU COPPER

DR DOOR

EC EMPTY CONDUIT

EMER EMERGENCY

EWC ELECTRIC WATER HEATER

EX EXISTING

G, GND GROUND

GF GROUND FAULT INTERRUPTER

HH HANDHOLE

HP HORSEPOWER

HS HOOD SUPPRESSION CONTROL

HZ HERTZ

IG ISOLATED GROUND

JB JUNCTION BOX

KVA KILOVOLT-AMPERES

KW KILOWATTS

LC LIGHTING CONTACTOR

LTG LIGHTING

PROVIDE FURNISH, INSTALL & CONNECT

RECPT RECEPTACLE

RL EXISTING ITEM TO BE RELOCATED

RM EXISTING ITEM TO REMAIN

RP EXISTING ITEM TO BE REPLACED

SC SECURITY CAMERA OUTLET

SN SOLID NEUTRAL

SW SWITCH

SWBD SWITCHBOARD

TV COMBINATION TV & RECEPT OUTLET

TYP TYPICAL

UG UNDER GROUND

UNO UNLESS NOTED OTHERWISE

V VOLT

LC LIGHTING CONTACTOR

WP WEATHERTIGHT GFI

WAP WIRELESS ACCESS POINT

XFMR TRANSFORMER

THIS SCHEDULE IS REPRESENTATIVE OF THOSE TYPICALLY FOUND ON THE PLANS BUT NOT ALL MAY BE UTILIZED

FIRE ALARM MANUAL PULL STATION, MOUNT AT 48" ABOVE FINISHED FLOOR. SUBSCRIPT

"K" INDICATES KEY OPERATED INSTITUTIONAL DEVICE.

ELECTRICAL SYMBOL LEGEND

FIRE ALARM COMBINATION CHIME AND STROBE DEVICE, SUBSCRIPT INDICATES CANDELA

RATING OTHERWISE 15 CANDELA. MOUNT AT A MINIMUM OF 80" ABOVE FINISHED FLOOR AND A

MINIMUM OF 6" BELOW FINISHED CEILING HEIGHT.

FIRE ALARM STROBE DEVICE, SUBSCRIPT INDICATES CANDELA RATING OTHERWISE 15

CANDELA. MOUNT AT A MINIMUM OF 80" ABOVE FINISHED FLOOR AND A MINIMUM OF 6" BELOW

FINISHED CEILING HEIGHT.

FIRE ALARM SMOKE DETECTOR, CEILING SURFACE MOUNTED.

FIRE ALARM SYSTEM DUCT DETECTOR WITH SAMPLING TUBES, FURNISHED AND WIRED BY

ELECTRICAL CONTRACTOR TO THE LOCAL FACP, INSTALL BY MECHANICAL CONTRACTOR

UNLESS OTHERWISE INDICATED.

FIRE ALARM SYSTEM DUCT DETECTOR REMOTE INDICATOR LIGHT.L

FIRE ALARM SYSTEM RELAY, CONTROL OR MONITORING TYPE AS REQUIRED.

FIRE ALARM END OF LINE RESISTOR.EOLR

RM

FIRE ALARM SPRINKLER SYSTEM FLOW SWITCH.

FIRE ALARM SPRINKLER SYSTEM TAMPER SWITCH.

FIRE ALARM SYSTEM HEAT DETECTOR.

FIRE ALARM SYSTEM SPEAKER, WALL MOUNTED.

FIRE ALARM SYSTEM SPEAKER, CEILING MOUNTED.

FIRE ALARM SYSTEM HORN/STROBE, CEILING MOUNTED.H

FIRE ALARM SYSTEM STROBE, CEILING MOUNTED.

FIRE ALARM SYSTEM DOOR HOLD OPEN DEVICE.

FIRE ALARM VOICE NOTIFICATION AMPLIFIER AND STROBE POWER SUPPLYFAVP

FIRE ALARM ADDRESSABLE VOICE COMMAND CONTROL PANEL

FIRE ALARM STANDARD ADDRESSABLE CONTROL PANEL

A. ALL WORK SHALL BE DONE ACCORDING TO THE NATIONAL ELECTRICAL CODE AND OTHER

APPLICABLE REFERENCED CODES. TAKE PARTICULAR CARE TO OBSERVE DURING BID

PREPARATION ANY POSSIBLE CODE DISCREPANCIES AND BRING TO THE ATTENTION OF

THE ENGINEER FOR RESOLUTION.

B. THE CONTRACTOR SHALL MAINTAIN, ON THE SITE, AN ADEQUATE ADMINISTRATIVE SPACE

WHERE ONE COMPLETE SET OF PLANS AND SPECIFICATIONS SHALL BE KEPT FOR THE

WORK OF ALL TRADES ON THE PROJECT. THESE PLANS AND SPECIFICATIONS SHALL BE IN

ADDITION TO THE SETS USED BY THE INSTALLING ELECTRICIAN IN CARRYING OUT THEIR

DAY-TO-DAY WORK ON THE PROJECT.

C. CONTRACTOR SHALL ALSO MAINTAIN AT THE SITE A COMPLETE SET OF ALL SHOP

DRAWINGS, EQUIPMENT CUTS, MANUFACTURER'S WIRING DIAGRAMS AND INSTALLATION

DATA. INSTALLING PERSONNEL SHALL STUDY THIS DATA BEFORE AND DURING

INSTALLATION AND ROUGH-IN SO AS TO PREPARE FOR THE PROPER FIT AND FUNCTION

UPON COMPLETION.

D. PENETRATIONS OF REQUIRED SMOKE TIGHT PARTITIONS SHALL BE SEALED USING U.L.

LISTED METHODS. COORDINATION WITH THE OWNER AND ENGINEER SHALL BE

MAINTAINED TO INSURE THAT THE INTEGRITY OF THE SMOKE BARRIER IN MAINTAINED.

E. WHERE PENETRATIONS ARE MADE THROUGH A REQUIRED FIRE-RESISTIVE WALL, FLOOR,

OR PARTITION FOR THE PURPOSE OF RUNNING CABLE OR RACEWAYS FIRE STOP PER

NFPA. COORDINATION WITH THE OWNER AND ENGINEER SHALL BE MAINTAINED TO

INSURE THAT THIS FIRE STOPPING IS ACCOMPLISHED. USE ONLY APPROVED ASSEMBLIES

SUCH AS THE FOLLOWING:

F. CONDUIT PENETRATIONS OF 1 & 2 HOUR GYPBOARD WALLS - U.L.#WL1001 CONDUIT

PENETRATIONS OF 1 & 2 HOUR CONCRETE OR BLOCK WALLS - U.L.#CAJ1001 CONDUIT

PENETRATIONS OF 1 & 2 HOUR CONCRETE FLOORS - U.L.#CAJ1001.

G. ALL ELECTRICAL MATERIALS, DEVICES, APPLIANCES AND EQUIPMENT SHALL BE U.L.

LISTED AND LABELED.

H. NEW FLOOR AND WALL SLEEVES SHALL BE HILTI-CP653 FOUR INCH SPEED SLEEVES.

I. BEFORE STARTING WORK THE CONTRACTOR SHALL PERFORM A COMPLETE

WALK-THROUGH OF THE PROJECT TO EXAMINE EXISTING EQUIPMENT, DEVICES AND THE

WORK REQUIRED. PROVIDE A REPORT OF ANY OBSERVATIONS THAT MAY AFFECT THE

WORK.

J. WHERE NEW DEVICES ARE INDICATED TO BE ADDED TO EXISTING SYSTEMS, THE NEW

DEVICES SHALL BE FULLY COMPATIBLE WITH THE EXISTING SYSTEMS AS TO MAINTAIN

ALL SYSTEM FUNCTIONS AND ALL REQUIRED FIRE ALARM CONFORMANCE LISTING,

INDEPENDENT TESTING LABORATORY LABELINGS, AND ALL EXISTING FIRE ALARM

SERVICE CONTRACTS.

FIRE ALARM SYSTEM SPEAKER/STROBE, CEILING MOUNTED.

M

F

F

FS

TS

F

GENERAL NOTES ABBREVIATIONS & ACRONYMS

FAVC

FACP

FASP

FAVA

FAAP

FIRE ALARM STROBE POWER SUPPLY

FIRE ALARM VOICE DIGITAL AMPLIFIER

FIRE ALARM ANNUNCIATION PANEL

FIRE ALARM SYSTEM HORN/STROBE, WALL MOUNTED.H

F

FIRE ALARM SYSTEM CARBON MONOXIDE DETECTORC

1 2 3 4 5

D C

B A

D C

B A

1 2 3 4 5 6

6" th re e in ch es o ne fo ot

6" th re e qu ar te rs in ch o ne fo ot

6" on e in ch o ne fo ot on e an d on e ha lf in ch es o ne fo ot on e ha lf in ch o ne fo ot

6" th re e ei gh th s in ch o ne fo ot on e ei gh th in ch o ne fo ot on e qu ar te r i nc h on e fo ot

PROJECT NUMBER

BUILDING NUMBER

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

APPROVED

FULLY SPRINKLERED

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

U.S. Department of Veterans Affairs

PHASEARCHITECT/ENGINEER OF RECORD

A/E:

STAMP

HARRELL DESIGN GROUP PC

8016 TOWER POINT DRIVE

CHARLOTTE, NC 28227

704-814-1346 POC: LEE HARRELL PE, LEED AP, QCxP

PRESIDENT

WWW.HARRELLDG.COM

637-19-102

APRIL 16, 2021

HDG PROJECT: 19037Revision Number Revisions: Date:

CHARLES GEORGE VA MEDICAL CENTER

UPGRADE HVAC, B-47 PHASE 5CONSTRUCTION

DOCUMENTS 100%

H D E S I G N G R O U P , P C

ARRE L L

FA100

GENERAL NOTES AND LEGENDS

John G. Ross, PE

2021.04.21 20:50:56 -04'00'

FIRST FLOOR ROOF

H

G

J

L

K

J

P

M

JN

O

FIRST FLOOR ROOF

H

G

J

L

K

J

P

M

JN

O

1 2 3 4 5

D C

B A

D C

B A

1 2 3 4 5 6

6" th re e in ch es o ne fo ot

6" th re e qu ar te rs in ch o ne fo ot

6" on e in ch o ne fo ot on e an d on e ha lf in ch es o ne fo ot on e ha lf in ch o ne fo ot

6" th re e ei gh th s in ch o ne fo ot on e ei gh th in ch o ne fo ot on e qu ar te r i nc h on e fo ot

PROJECT NUMBER

BUILDING NUMBER

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

APPROVED

FULLY SPRINKLERED

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

U.S. Department of Veterans Affairs

PHASEARCHITECT/ENGINEER OF RECORD

A/E:

STAMP

HARRELL DESIGN GROUP PC

8016 TOWER POINT DRIVE

CHARLOTTE, NC 28227

704-814-1346 POC: LEE HARRELL PE, LEED AP, QCxP

PRESIDENT

WWW.HARRELLDG.COM

637-19-102

APRIL 16, 2021

HDG PROJECT: 19037Revision Number Revisions: Date:

CHARLES GEORGE VA MEDICAL CENTER

UPGRADE HVAC, B-47 PHASE 5CONSTRUCTION

DOCUMENTS 100%

H D E S I G N G R O U P , P C

ARRE L L

FA103

ROOF FIRE ALARM PLAN

D1

FA103

FIRST FLOOR ROOF

SECOND FLOOR ROOF

SECOND

FLOOR

ROOF FIRST

FLOOR

ROOF

SIXTH FLOOR ROOF

SIXTH FLOOR ROOF SIXTH FLOOR ROOF

PENTHOUSE ROOF

FIRST

FLOOR

ROOF

FIRST FLOOR ROOF

FIRST FLOOR ROOF

FIRST

FLOOR

ROOF

LOWER

ROOF

FIRST

FLOOR

ROOF

HIGHER

ROOF

11 12 13 14 15 16 17 18 19 2015 16 17 18 19

D

C

B

A

20876

H

G

F

E

D

C

B

9 10

J

8 9 10

L

K

J

14 15 16 17

C

1312111098

V.9

5.63.9

S.9

U.2

P

M

JN

O

Q

R

A

21 22 23 24 25 26

G

H

J

K

L

M

N

O

P

Q

R

S

26252423

T

U

V

7.4

5 6

2021.04.21 20:51:19 -04'00'

SECOND FLOOR ROOF

SECOND

FLOOR

ROOF

FIRST

FLOOR

ROOF

FIRST

FLOOR

ROOF

G

H

J

K

L

M

N

O

P

SECOND FLOOR ROOF

SECOND

FLOOR

ROOF

FIRST

FLOOR

ROOF

FIRST

FLOOR

ROOF

G

H

J

K

L

M

N

O

P

1 2 3 4 5

D C

B A

D C

B A

1 2 3 4 5 6

6" th re e in ch es o ne fo ot

6" th re e qu ar te rs in ch o ne fo ot

6" on e in ch o ne fo ot on e an d on e ha lf in ch es o ne fo ot on e ha lf in ch o ne fo ot

6" th re e ei gh th s in ch o ne fo ot on e ei gh th in ch o ne fo ot on e qu ar te r i nc h on e fo ot

PROJECT NUMBER

BUILDING NUMBER

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

APPROVED

FULLY SPRINKLERED

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

U…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .