36C24618R0135-015.pdf

PDF 5 MB Posted

Attached to
SCI Expansion, 652-314 (VA-17-900410) Federal contract opportunity
Solicitation number
36C24618R0135
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6

About this file

36C24618R0135 SCI DWGS 07.pdf

View the file

Other files for this federal contract opportunity

Other files attached to SCI Expansion, 652-314 (VA-17-900410), newest first.
File Type Posted
36C24618R0135-00003000.docx DOCX document
36C24618R0135-00002001.pdf PDF
36C24618R0135-00002000.docx DOCX document
36C24618R0135-010.pdf PDF
36C24618R0135-006.docx DOCX document
36C24618R0135-012.pdf PDF
36C24618R0135-003.docx DOCX document
36C24618R0135-014.pdf PDF
36C24618R0135-002.docx DOCX document
36C24618R0135-013.pdf PDF
36C24618R0135-016.pdf PDF
36C24618R0135-009.pdf PDF
36C24618R0135-017.pdf PDF
36C24618R0135-007.docx DOCX document
36C24618R0135-001.docx DOCX document
36C24618R0135-011.pdf PDF
36C24618R0135-005.docx DOCX document
36C24618R0135-008.pdf PDF
36C24618R0135-004.docx DOCX document
36C24618R0135-000.docx DOCX document
Show all 20

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MISCELLANEOUS ABBREVIATIONS

SYMBOLS DESCRIPTION

PIPELINE ABBREVIATIONS HVAC SYMBOLS

EQUIPMENT TAG ABBREVIATIONS

DESCRIPTIONSYMBOLS

PIPELINE SYMBOLS

DOUBLE LINE SHEETMETAL

SINGLE LINE - SHEET METAL

DESCRIPTIONSYMBOLS

CHILLED WATER RETURN

CHILLED WATER SUPPLY

HOT WATER HEATING RETURN

HOT WATER HEATING SUPPLY

INVERTED ECCENTRIC REDUCER

(VENTURI FLOW STATION)

TWO-WAY MODULATING

THREE-WAY MODULATING CONTROL VALVE

SAFETY VALVE OR PRESSURE RELIEF

PRESSURE REDUCING VALVE

BALANCING COCK

WATER FLOW MEASURING DEVICE

PIPING TURNED DOWN

TWO-WAY CONTROL VALVE

MOTORIZED VALVE

AUTOMATIC AIR VENT

SECURITY SUPPLY DIFFUSER CEILING

SECURITY SMOKE EXHAUST FAN

STATIC PRESSURE SENSOR

TEMPERATURE CONTROL VALVE

SUPPLY LINEAR SLOT DIFFUSER

THERMOMETER

TEMPERATURE RISE

TURNING VANES

TEMPERATURE

STATIC PRESSURE

SMOKE DAMPER

SECURITY SUPPLY GRILLE CEILING

SECURITY SUPPLY GRILLE WALL

SHEET METAL

TRIPLE DUTY VALVE

VARIABLE AIR VOLUME

WATER TEMPERATURE DROP

VOLUME CONTROL DAMPER

WATER FLOW MEASURING DEVICE

VENTURI FLOW STATION

WATER GAUGE

HORSE POWERHP

INSULATED METAL ENCLOSURE

INVERTED ECCENTRIC REDUCER

HORIZONTAL UNIT HEATER

HOT WATER SUPPLY AND RETURNHWS&R

INTERL

IME

INV

IER

INSUL

INCL

IN

HTG

HPD

HWS

HV

HWR

DHW

HUH

INCLUDED

INVERT

INCHES

INSULATION

INTERLOCK

HIGH PRESSURE DRIP

HOT WATER SUPPLY

HOT WATER RETURN

HIGH VELOCITY

HEATING

DOMESTIC HOT WATER

W/O W/

WITH OUT

WITH

EXHAUST REGISTER

ELECTRICAL CONTRACTOR

ENTERING AIR TEMPERATURE

FINAL AIR TEMPERATURE

EXHAUST REGISTER WALL

ENTERING WATER TEMPERATURE

GRAVITY INTAKE VENTILATOR

FROMFRM

GA

GRAV

GC

GPM

GL V

GIV

HC

GV

FT HD

FLR DR

FCU

FD

FC

FAT

S/FD

GAUGE

GENERAL CONTRACTOR

GALLONS PER MINUTE

HEATING CONTRACTOR

GATE VALVE

GLOBE VALVE

GRAVITY

FAN COIL UNIT

FLEXIBLE CONNECTION

FIRE DAMPER

FEET OF HEAD

FLOOR DRAIN

SMOKE/FIRE DAMPER

FLG C

ER

FPB

FLR

EWB

EWT

ERW

EA

EMER

EAT

EDB

EC

EXH

ETR

EQUIP

FAN POWERED BOX

FLANGE CONNECTION

ENTERING WET BULB

FLOOR

ENTERING DRY BULB

EXHAUST AIR

EXISTING TO REMAIN

EXHAUST

EQUIPMENT

EMERGENCY

VAV

V

VD

VFS

WTD

WFMD

WG

WB

TV

TRANS

TR

TCV

TSTAT

TYP

UC

VALVE

WET BULB

TYPICAL

TRANSITION

THERMOSTAT

UNDERCUT

SHT MTL

STR

SP

TEMP

TA

SPS

TDV

TH

SD

SSEF

SSGC

SSGW

SHT

SLSD

STL

STRAINER

THROWAWAY

SHEET

STEEL

PIPING TURNED UP

FUNNEL DRAIN

CONTROL VALVE

A

M

MANUAL AIR VENT

(TWO POSITION TYPE)

AQUASTAT

PRESSURE TAP

LEAVING WET BULB

LEAVING DRY BULB

LEAVING WATER TEMPERATURE

LEAVING AIR TEMPERATURE

MANUAL AIR VENT

MIXED AIR TEMPERATURE

MANUFACTURER

ISOLATION VALVE STATION

LINEAR SUPPLY DIFFUSER CEILING

RETURN GRILLE

ONE THOUSAND BTU/HOUR

OUTSIDE SCREW AND YOKE

PRESSURE REDUCING VALVE

PRESSURE GAUGE WITH COCK

PRESSURE DIFFERENTIAL VALVE

MOTOR OPERATED DAMPER

PRESSURE TAP

RETURN AIR GRILLE

PLUMBING CONTRACTOR

OPPOSED BLADE DAMPER

PUMP DISCHARGE

NOT APPLICABLE

MECHANICAL EQUIPMENT ROOM

NOT TO SCALE

RETURN AIR/RELIEF AIR

RETURN REGISTER

RELIEF VALVE

BACKDRAFT DAMPERBDD

CHILLED WATER SUPPLY/RETURN

DISCH

DPR

DO

DN

DWG

DR

EF

DX

CORR

CO

CV

CIRC

CFM

DIFF

DB

DCW

EXHAUST FANS

DIRECT EXPANSION

DAMPER

DITTO

DOWN

DISCHARGE

DRAWING

DRAIN

CIRCULATOR

CONTROL VALVE

DOMESTIC COLD WATER

CUBIC FEET PER MINUTE

CLEANOUT

CORRIDOR

DIFFUSER

DRY BULB

CONTR

CLG MTD

CONN

CONT

COL

CONC

CD

CONV

CHK V

CHWS&R

CAP

CHWR

CHWS

CLG

CFH

CEILING MOUNTED

CONTRACTOR

CONNECTION

CONDENSATE DRAIN

CONVECTOR

CONTINUE

CONCRETE

COLUMN

CHILLED WATER RETURN

CHILLED WATER SUPPLY

CHECK VALVE

CUBIC FEET/ HOUR

CAPACITY

CEILING

RA

RG

RAG

RR

SCH

RV

SA

PD

PT

PG

PRV

REQD

RM

RET

SCHEDULE

SUPPLY AIR

REQUIRED

ROOM

RETURN

MER

OBD

OS&Y

PC

OA

OPNG

OPER

NA

PRD

MAV

MAT

NTS

MBH

MH

MOD

OPENING

OPERATED

OUTSIDE AIR

MANHOLE

AIR FLOW MEASURING DEVICE

AVERAGE WATER TEMPERATURE

AUTOMATIC TEMPERATURE CONTROL

ACC

AP

ATC

BC

BLW

B

BLDG

AWT

APPROX

AAV

ABV

AUTO

AFF

AFMD

AD

BALANCING COCK

AIR COOLED CHILLER

ACCESS PANEL

BUILDING

BOILER

BELOW

AUTOMATIC AIR VENT

APPROXIMATELY

ABOVE FINISHED FLOOR

ACCESS DOOR

ABOVE

AUTOMATIC

LWT

MECH

MAX

MTD

MIN

MTR

MTL

MFGR

LDB

IVS

LTG

LAT

LWB

LSDC

LF

MAXIMUM

MECHANICAL

MOUNTED

MINIMUM

MOTOR

METAL

LIGHTING

LINEAR FEET

THERMOMETER

STRAINER

PRESSURE GAUGE

UNION

ECCENTRIC REDUCER

MANUAL VOLUME CONTROL DAMPER (VD)

RISE/DROP IN DUCTWORK

(ARROW SHOWS DIRECTION OF DROP)

SMOKE DAMPER/DETECTOR

PANEL IN DUCT AND CEILING)

EXHAUST AIR DUCT DN

SUPPLY AIR DIFFUSER

ACCESS DOOR ON SIDE OF DUCT

EXHAUST REGISTER

RETURN AIR REGISTER

ACCESS DOOR ON BOTTOM OF DUCT

DETECTOR BY E.C. DAMPER BY H.C.

FIRE DAMPER AT FIRE WALL (PROVIDE ACCESS

OR HORIZONTAL DUCT ABOVE CEILING (PROVIDE

FIRE DAMPER IN VERTICAL DUCT THRU FLOOR

ACCESS PANEL IN DUCT AND WALL OR CEILING)

SUPPLY AIR REGISTER (DUCT OR WALL)

EXHAUST/RETURN AIR REGISTER (DUCT OR WALL)

COMBINATION FIRE/SMOKE DAMPER

MOTORIZED DAMPER

SUPPLY DUCT DN

RETURN AIR DUCT DN

EXHAUST AIR DUCT UP

RETURN AIR DUCT UP

SUPPLY DUCT UP

ROUND SUPPLY, RETURN OR

OVAL SUPPLY, RETURN OR

RECTANGULAR SUPPLY, RETURN OR

DIRECTION OF AIR FLOW)

DUCT W/O TURNING VANES

DUCT MOUNTED SMOKE

BY EC, INSTALLED BY HC

RELIEF DUCT WIDTH (SHOWN)XDEPTH

RELIEF DUCT WIDTH (SHOWN)XDEPTH

LOW LOSS TAKE OFF (ARROW INDICATES

RADIUS ELBOW (DUCT WIDTH 17" AND LOWER)

(ARROW INDICATES AIR FLOW DIRECTION)

BOOT CONNECTION WITH MANUAL VD

DUCT W/TURNING VANES (DUCT WIDTH OVER 18")

WALL SWITCH

DUCT/SPACE STATIC PRESSURE SENSOR

DETECTOR PROVIDED

CONICAL SPIN-IN FITTING

24"X24"24"X24"

12"X12"

DD

S

WS

M

AD

REFRIGERANT LINE

REFRIGERANT SUCTION

RL

RS

HWHS

HWHR

CHWS

CHWR

THERMAL VAV DIFFUSERTF

UNIT HEATERUH

SSDC

AIR COOLED CONDENSING UNITACCU

ACCUMULATORACCUM

AIR HANDLING UNITAHU

AIR SOURCE HEAT PUMPASHP

BASEBOARD HEATERBB

BD BAROMETRIC DAMPER

BACK DRAFT DAMPERBDD

CHILLED WATER COOLING COILCC

COMPRESSORCMPR

CONV CONVECTOR

CABINET UNIT HEATER

CP

CUH

CONDENSATE PUMP

DC DRY COOLER

EXPANSION TANKET

ELECTRIC CABINET UNIT HEATERECUH

ELECTRIC UNIT HEATEREUH

ELECTRIC WALL HEATEREWH

EVAPORATOREVAP

FINNED TUBE RADIATIONFT

FURNACEFU

GRV GRAVITY ROOF VENTILATOR

HC HOT WATER HEATING COIL

HUMIDIFIERH

RCP RADIANT CEILING PANEL

RTU ROOF TOP UNIT

SF SUPPLY FAN

SSAC SPLIT SYSTEM AIR CONDITIONING UNIT

P PUMP

PTAC PACKAGED TERMINAL AIR CONDITIONING UNIT

UNIT VENTILATORUV

CD CONDENSATE DRAIN LINE

MPS MEDIUM PRESSURE STEAM SUPPLY

MPCR MEDIUM PRESSURE CONDENSATE RETURN

PUMPED CONDENSATEPC

HRS ENERGY (HEAT) RECOVERY SUPPLY

HRR ENERGY (HEAT) RECOVERY RETURN

NAME PIPE TO BE REMOVED

NAME EXISTING PIPING TO REMAIN

TEE- OUTLET

SIDE CONNECTION

CAPPED OUTLET

TEE - OUTLET UP

12"X12"

12"/12"

RELIEF VALVE

BUTTERFLY VALVE

PIPE BREAK (SINGLE LINE)

DIRECTION OF FLOW

FLEXIBLE CONNECTION

BACKFLOW PREVENTION DEVICE

DUCT END CAP

24X12

SQUARE ELBOW WITH

TURNING VANES

RADIUS TURN ELBOW

RETURN CROSS

SECTION DN

EXHAUST CROSS

SECTION UP

SUPPLY DUCT

CROSS SECTION DN

RETURN CROSS

SECTION UP

CROSS SECTION UP

SUPPLY DUCT

ROUND DUCT SIZE (DIAMETER)

FLEXIBLE DUCT (DIAMETER SIZE)

DUCT SIZE (WIDTH X DEPTH)

24"Ø

DUCT W/ TURNING VANES

CONDENSER WATER RETURN

CONDENSER WATER SUPPLYCWS

CWR

CTD COOLING TOWER DRAIN LINE

UNDER CUT DOORUCD

BALL VALVE

(HINGED & GASKETED)

(HINGED & GASKETED)

FD

F/SD

FDFD

LPS LOW PRESSURE STEAM SUPPLY

LPCR LOW PRESSURE CONDENSATE RETURN

HPS HIGH PRESSURE STEAM SUPPLY

HPCR HIGH PRESSURE CONDENSATE RETURN

REX REMOVE EXISTING

EXISTINGEX

BACKDRAFT DAMPER

B

DUCT/WALL TEMPERATURE SENSOR, ELECTRICT

24"Ø

12"Ø

DRAWING SYMBOLS

DRAWING NUMBER WHERE DRAWN

H200

SECTION LETTER

DRAWING NUMBER WHERE DRAWNH100

DETAIL NUMBER

CONNECT TO EXISTING AT THIS POINT

DEMO/REMOVE TO THIS POINT

EQUIPMENT NUMBER1

VAV POWERED EQUIPMENT

EQUIPMENT NUMBER1

RHC NON-POWERED EQUIPMENT

CD-#

DIFFUSER/REGISTER/GRILLE TYPE

AIRFLOW QUANTITY

KEYNOTE (DEMO SCOPE)

KEYNOTE (NEW WORK SCOPE)

1. EXISTING BUILDING AUTOMATION SYSTEM (BAS) DIRECT-DIGITAL CONTROL SYSTEM IS METASYS

MANUFACTURED BY JOHNSON CONTROLS. ALL NEW DDC EQUIPMENT TO BE JOHNSON CONTROLS

METASYS SYSTEM. NAME BRAND ONLY. NO OTHER MANUFACTURER TO BE ACCEPTED.

HVAC CONTROLS

1. NOT ALL SYMBOLS ARE NECESSARILY USED.

2. COORDINATE FINAL LOCATIONS OF DIFFUSERS AND GRILLES WITH ARCHITECTURAL REFLECTED CEILING

PLANS.

3. DRAWINGS ARE DIAGRAMMATIC. CONTRACTOR TO FIELD VERIFY DUCT AND PIPE ROUTING AND

COORDINATE INTERFERENCE BETWEEN TRADES PRIOR TO INSTALLATION.

4. ROOF OPENINGS, FLASHING, AND COUNTER FLASHING BY GENERAL CONTRACTOR. LOCATION OF

OPENINGS BY HEATING CONTRACTOR.

5. DUCTWORK TO BE INSTALLED TIGHT TO UNDERSIDE OF STRUCTURE ABOVE UNLESS NOTED OTHERWISE.

6. PROVIDE ALL MATERIALS, EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO INSTALL COMPLETE AND OPERABLE MECHANICAL SYSTEMS AS INDICATED ON THE DRAWINGS, AS SPECIFIED, AND AS REQUIRED BY

CODE.

7. CONTRACT DOCUMENT DRAWINGS FOR MECHANICAL WORK ARE DIAGRAMMATIC AND ARE INTENDED TO CONVEY SCOPE AND GENERAL ARRANGEMENT ONLY. CONTRACTOR SHALL BE RESPONSIBLE TO FIELD SURVEY ACTUAL SITE CONDITIONS AND ACCOMMODATE ACTUAL SITE CONDITIONS AS PART OF SCOPE OF

WORK AT NO COST TO OWNER.

8. INSTALL ALL MECHANICAL EQUIPMENT AND APPURTENANCES IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, CONTRACT DOCUMENTS, APPLICABLE BUILDING, STATE, AND LOCAL CODES, SEISMIC

REQUIREMENTS, ENERGY CODES, AND INSURANCE UNDERWRITER REQUIREMENTS.

9. COORDINATE CONSTRUCTION OF ALL MECHANICAL WORK WITH ARCHITECTURAL, STRUCTURAL, CIVIL, AND

ELECTRICAL WORK, ETC. SHOWN ON OTHER CONTRACT DOCUMENT DRAWINGS.

10. MAINTAIN A MINIMUM OF 6'-8" CLEARANCE TO UNDERSIDE OF PIPES, DUCTS, CONDUITS, SUSPENDED

EQUIPMENT, SUPPORTS, ETC., THROUGHOUT ACCESS ROUTES IN MECHANICAL ROOMS.

11. ALL TESTS SHALL BE COMPLETED AND ACCEPTED BY THE INSPECTOR BEFORE ANY MECHANICAL

EQUIPMENT OR PIPING INSULATION IS APPLIED.

12. LOCATE ALL TEMPERATURE, PRESSURE AND FLOW MEASURING DEVICES IN ACCESSIBLE LOCATIONS WITH A STRAIGHT SECTION OF PIPE OR DUCT UPSTREAM AND DOWNSTREAM, AS RECOMMENDED BY THE

MANUFACTURER FOR ACCURACY.

13. TESTING ADJUSTING AND BALANCING (TAB) AGENCY SHALL BE A MEMBER OF THE ASSOCIATED AIR BALANCING COUNCIL (AABC) OR THE NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB). TAB FIRM SHALL HAVE A MINIMUM OF 5 YEARS EXPERIENCE ON SIMILAR PROJECTS. PERFORM TAB IN ACCORDANCE WITH THE REQUIREMENTS OF THE TAB PROCEDURAL STANDARD RECOMMENDED BY THE TAB TRADE ASSOCIATION THAT

APPROVED THE TAB FIRM'S QUALIFICATIONS.

14. WHERE TWO OR MORE ITEMS OF THE SAME TYPE OF EQUIPMENT ARE REQUIRED, THE PRODUCTS OF A

SINGLE MANUFACTURER SHALL BE USED.

15. COORDINATE ALL FINAL EQUIPMENT CONNECTIONS WITH MANUFACTURERS' CERTIFIED DRAWINGS.

COORDINATE AND PROVIDE ALL DUCTWORK AND PIPING TRANSITIONS REQUIRED FOR FINAL EQUIPMENT CONNECTIONS TO FURNISHED EQUIPMENT. FIELD VERIFY AND COORDINATE ALL DUCTWORK AND PIPING

DIMENSIONS BEFORE FABRICATION.

16. ALL CONTROL WIRE AND CONDUIT SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE, DIVISION 26 OF THE

SPECIFICATIONS, ALL LOCAL CODES, AND OWNER'S INSURANCE UNDERWRITER REQUIREMENTS.

17. THE LOCATIONS AND SIZES OF ALL ITEMS SHOWN ON THE DRAWINGS OR CALLED FOR IN THE SPECIFICATIONS THAT ARE NOT DEFINITELY FIXED BY DIMENSIONS ARE APPROXIMATE ONLY. THE EXACT LOCATIONS AND SIZES NECESSARY TO SECURE THE BEST CONDITIONS AND RESULTS SHALL BE DETERMINED BY THE PROJECT SITE CONDITIONS AND SHALL HAVE THE APPROVAL OF THE ENGINEER BEFORE BEING INSTALLED. DO NOT SCALE

DRAWINGS.

18. PLAN DRAWINGS AND SECTION CUTS WHICH SPECIFICALLY IDENTIFY SERVICE ROUTE OFFSETS, ELEVATION CHANGES, OBSTRUCTIONS, ACCESS DOORS, BALANCING DEVICES, ETC. ARE SHOWN FOR CLARITY WHERE SPECIFIC KNOWN CONDITIONS EXIST. MECHANICAL CONTRACTOR SHALL COORDINATE EQUIPMENT, DUCTWORK, AND PIPING ROUTINGS WITH ALL OTHER TRADES. REQUIREMENTS NOT SPECIFICALLY IDENTIFIED SHALL NOT BE INTERPRETED AS EXCLUSION FROM CONTRACTOR'S SCOPE OF WORK. CONTRACTOR SHALL BE RESPONSIBLE FOR ACTUAL SITE CONDITIONS AND SHALL INCLUDE SUCH CONDITIONS IN SCOPE OF WORK AT NO ADDITIONAL

COST TO THE OWNER.

19. ALL MISCELLANEOUS STEEL REQUIRED TO ENSURE PROPER INSTALLATION AND SUPPORT OF MECHANICAL WORK AS SHOWN IN DETAILS FOR PIPING, DUCTWORK AND EQUIPMENT (UNLESS OTHERWISE NOTED) SHALL BE FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER.

20. ALL EQUIPMENT, PIPING, DUCTWORK, ETC., SHALL BE SUPPORTED AS DETAILED, SPECIFIED AND AS

REQUIRED TO PROVIDE A VIBRATION FREE INSTALLATION.

21. ALL OPENINGS IN FIRE RATED WALLS AND SMOKE PARTITIONS DUE TO DUCTWORK, PIPING, CONDUIT, ETC., SHALL BE FIRE STOPPED WITH APPROVED FIRESTOPPING MATERIALS.

22. REFER TO TYPICAL DETAILS FOR DUCTWORK, PIPING AND EQUIPMENT INSTALLATION.

23. UNLESS OTHERWISE SHOWN, LOCATE ALL ROOM THERMOSTATS WITH TOP AT 48" ABOVE FINISHED FLOOR IN ACCORDANCE WITH ADA REQUIREMENTS. NOTIFY THE ENGINEER OF ANY ROOMS WHERE THE ABOVE LOCATION CAN NOT BE MAINTAINED OR WHERE THERE IS A QUESTION ON LOCATION. COORDINATE FINAL LOCATIONS WITH

OWNER.

24. LOCATE ALL MECHANICAL EQUIPMENT (VAV BOXES, CABINET HEATERS, UNIT HEATERS, ETC.,) FOR UNOBSTRUCTED ACCESS TO UNIT ACCESS PANELS, FILTERS, CONTROLS AND VALVING. DO NOT LOCATE FAN

POWERED VAV BOXES ABOVE LIGHTING FIXTURES.

25. PROVIDE FLEXIBLE CONNECTIONS IN ALL DUCTWORK SYSTEMS (SUPPLY, RETURN AND EXHAUST) CONNECTED TO FANS AND OTHER EQUIPMENT WHICH REQUIRE VIBRATION ISOLATION. FLEXIBLE CONNECTIONS SHALL BE PROVIDED AT THE POINT OF CONNECTION TO THE EQUIPMENT UNLESS OTHERWISE INDICATED.

26. ALL LOUVERS SHALL BE FURNISHED AND INSTALLED BY THE GENERAL CONTRACTOR (UNLESS OTHERWISE NOTED). GENERAL CONTRACTOR SHALL COORDINATE SIZES, LOCATIONS, AND CONNECTIONS WITH MECHANICAL CONTRACTOR. DUCTWORK CONNECTIONS TO LOUVERS SHALL BE FURNISHED AND INSTALLED BY MECHANICAL

CONTRACTOR.

27. PROVIDE AN AIR VENT AT THE HIGH POINT OF EACH DROP IN HYDRONIC WATER PIPING SYSTEMS. ALL PIPING SHALL SLOPE TO LOW POINTS. PROVIDE HOSE END DRAIN VALVES AT THE BOTTOM OF ALL RISERS AND LOW

POINTS.

28. INSTALL PIPING SO THAT ALL VALVES, STRAINERS, UNIONS, TRAPS, FLANGES, AND OTHER APPURTENANCES

REQUIRING ACCESS ARE ACCESSIBLE.

29. ALL ISOLATION VALVES SHALL BE IN A LOCATION AND ELEVATION WHICH ALLOWS FOR EQUIPMENT AND BRANCH PIPING REMOVAL, WHILE MAINTAINING SERVICE UPSTREAM OF THE ISOLATION VALVE.

30. ALL BALANCING VALVES AND ISOLATION VALVES USED TO ADJUST FLOW RATES SHALL BE PROVIDED WITH

POSITION INDICATORS AND MAXIMUM ADJUSTABLE STOPS (MEMORY STOPS).

31. ALL ISOLATION VALVES (EXCEPT CONTROL VALVES), STRAINER, AND PIPING SPECIALTIES AND STRAINERS SHALL BE FULL LINE SIZE BEFORE REDUCING SIZE TO MAKE CONNECTIONS TO EQUIPMENT AND CONTROLS.

32. MECHANICAL JOINTS SUCH AS UNIONS, FLANGES, OR THREADED FITTINGS SHALL BE INSTALLED AT EACH EQUIPMENT CONNECTION, IN BYPASSES, AT FLOOR PENETRATIONS, AT CONTROL DEVICES, AND IN LONG PIPE

RUNS (100 FEET OR MORE) TO PERMIT DISASSEMBLY FOR ALTERATION AND REPAIRS.

33. MEASURE, CUT, AND INSTALL PIPE LENGTH ACCURATELY TO MINIMIZE MISALIGNMENT. INSTALL ALL PIPING

WITHOUT FORCING OR SPRINGING.

34. PROVIDE FLEXIBLE CONNECTIONS IN ALL PIPING SYSTEMS CONNECTED TO PUMPS AND OTHER EQUIPMENT WHICH REQUIRE VIBRATION ISOLATION (EXCEPT WATER COILS). FLEXIBLE CONNECTIONS SHALL BE PROVIDED AS CLOSE TO THE EQUIPMENT AS POSSIBLE OR AS INDICATED ON THE DRAWINGS.

35. PROVIDE VIBRATION ISOLATION FOR ALL MECHANICAL EQUIPMENT TO PREVENT VIBRATION TRANSMISSION

TO BUILDING STRUCTURE.

36. CONCRETE HOUSEKEEPING PADS SHALL BE FURNISHED AND INSTALLED BY THE GENERAL CONTRACTOR.

MECHANICAL CONTRACTOR SHALL PROVIDE EQUIPMENT WEIGHTS, SIZES, AND LOCATION TO GENERAL CONTRACTOR. MINIMUM CONCRETE PAD THICKNESS SHALL BE IN ACCORDANCE WITH STRUCTURAL DETAILS.

PAD SHALL EXTEND BEYOND THE EQUIPMENT FOOTPRINT A MINIMUM OF 6 INCHES ON EACH SIDE.

37. ALL DUCTWORK, PIPING, AND EQUIPMENT SUPPORTED FROM STRUCTURAL STEEL SHALL BE

COORDINATED WITH GENERAL CONTRACTOR. ALL ATTACHMENTS TO STEEL MEMBERS, BAR JOISTS, TRUSSES, OR JOIST GIRDERS SHALL BE APPROVED BY STRUCTURAL ENGINEER. WELDING TO STRUCTURAL MEMBERS

SHALL NOT BE PERMITTED.

38. MECHANICAL EQUIPMENT, DUCTWORK, AND PIPING SHALL NOT BE SUPPORTED FROM ROOF OR DECK ASSEMBLY. SUPPORTS SHALL ATTACH TO STRUCTURAL MEMBERS. COORDINATE WITH STRUCTURAL

DRAWINGS.

39. PROVIDE MANUFACTURER'S MATCHING ROOF CURBS FOR ALL ROOF MOUNTED EQUIPMENT. COORDINATE ACTUAL ROOF PITCH AND CONSTRUCTION DETAILS WITH GENERAL CONTRACTOR. PROVIDE SLOPED CURBS PER MANUFACTURER'S RECOMMENDATIONS. GENERAL CONTRACTOR SHALL INSTALL ROOF CURBS AND

FLASHING PER ROOFING MANUFACTURER'S INSTALLATION REQUIREMENTS.

40. UNLESS OTHERWISE NOTED, ALL PIPING AND DUCTWORK IS OVERHEAD, TIGHT TO UNDERSIDE OF

STRUCTURE OR SLAB, WITH SPACE FOR INSULATION.

41. PROVIDE CHAINWHEEL OPERATORS FOR ALL EXPOSED VALVES MOUNTED GREATER THAN 8'-0" ABOVE FINISHED FLOOR LEVEL. CHAIN SHALL EXTEND UNOBSTRUCTED TO 7'-0" ABOVE FLOOR LEVEL.

42. ALL PIPING AND DUCTWORK SHALL CLEAR DOORS, WINDOWS, EQUIPMENT CLEARANCES, MAINTENANCE REQUIREMENTS, CODE SETBACKS, ETC. TO ASSURE PROPER OPERATION, INSPECTION, AND MAINTENANCE.

43. ALL VALVES SHALL BE ADJUSTED FOR SMOOTH AND EASY OPERATION.

44. PROVIDE ALL 90 DEGREE SQUARE ELBOWS WITH DOUBLE RADIUS TURNING VANES UNLESS OTHERWISE INDICATED OR SPECIFIED. PROVIDE ACCESS DOORS UPSTREAM OF ALL ELBOWS CONTAINING TURNING

VANES.

45. ALL DUCTS SHALL BE BONDED ACROSS FLEXIBLE CONNECTIONS WITH FLEXIBLE COPPER GROUNDING STRAPS. GROUNDING STRAPS SHALL BE BOLTED OR SOLDERED TO BOTH THE EQUIPMENT AND THE DUCT.

46. ALL EQUIPMENT SUBMITTALS AND SHOP DRAWINGS REQUIRED BY THE SPECIFICATIONS SHALL BE

APPROVED BY ENGINEER PRIOR TO PURCHASE, FABRICATION, AND INSTALLATION.

47. ALL HEATING DEVICES AND SURFACES WITH ELEVATED TEMPERATURES WHICH CAN BE ACCESSED OR COME IN CONTACT WITH OWNER PERSONNEL SHALL BE PROTECTED, INSULATED, OR CONTROLLED TO REMAIN

BELOW 120°F.

48. PROVIDE MANUAL VOLUME DAMPERS IN ALL RUN-OUTS TO DIFFUSERS, BRANCH TAKE-OFFS FROM MAIN SUPPLY DUCT, AND IN ALL OTHER AREAS REQUIRED TO PROVIDE PROPER SYSTEM AIRFLOW BALANCING.

HVAC GENERAL NOTES HVAC DEMOLITION NOTES

HVAC PHASING NOTES

1. THE CONTRACTOR SHALL THOROUGHLY EXAMINE THE SITE PRIOR TO SUBMITTING THEIR BID. DUE TO THE NATURE OF THIS PROJECT AND THE STATE OF THE EXISTING BUILDING, IT IS IMPOSSIBLE TO

COMPLETELY RELATE THE SCOPE OF THE DEMOLITION REQUIRED TO THE CONTRACTOR THROUGH

THE CONTRACT DOCUMENTS. FAILURE TO VISIT THE SITE WILL NOT RELIEVE THE CONTRACTOR OF

THEIR DEMOLITION RESPONSIBILITIES UNDER THIS CONTRACT. IT IS THE CONTRACTOR’S

RESPONSIBILITY TO DETERMINE AND COORDINATE THE EXACT EXTENT OF DEMOLITION NECESSARY TO

PROVIDE A RENOVATED AND UPGRADED SPACE AND TO FACILITATE NEW WORK.

2. INFORMATION REGARDING THE EXISTING CONDITIONS WAS GATHERED FROM AVAILABLE EXISTING DRAWINGS, SURVEY, AND CORRESPONDENCE WITH UTILITY, STAFF, AND FACILITIES PERSONNEL.

THERE ARE NO GUARANTEES AS TO THE ACCURACY OF THIS INFORMATION AND IT IS OFFERED FOR

INFORMATION ONLY.

3. VERIFY EXISTING LOCATIONS OF EQUIPMENT, DUCTWORK, PIPING AND SYSTEM COMPONENTS PRIOR TO DEMOLITION. IF EXISTING CONDITIONS ARE DIFFERENT THAN WHAT IS INDICATED ON THE

CONTRACT DOCUMENTS, THE CONTRACTOR SHALL NOTIFY THE COR AND ARCHITECT PRIOR TO

PROCEEDING WITH THE WORK.

4. MINIMIZE DISTURBANCE AND / OR DAMAGE TO EXISTING FINISHED SURFACES AND FINISHES. WHERE

DEMOLITION OF MECHANICAL SYSTEM COMPONENTS DAMAGES EXISTING SURFACES TO REMAIN,

RESTORE THOSE SURFACES TO THE SAME CONDITION AS THE ADJACENT SURFACES. RESTORATION

MUST BE PERFORMED BY WORKMEN SKILLED IN PERFORMING SUCH WORK. ALL FIRE AND SMOKE

RATINGS SHALL BE RETAINED AS PART OF THE REPAIRS. PATCH / SEAL HOLES WEATHERTIGHT. ALL

PATCHES AND REPAIRS ARE SUBJECT TO THE REVIEW AND APPROVAL OF THE ARCHITECT.

5. ALL AREAS OF EGRESS SHALL BE KEPT OPEN AND FREE FROM DEBRIS AT ALL TIMES.

6. DO NOT REMOVE ITEMS SUPPORTING OTHER ITEMS WITHOUT PROVIDING TEMPORARY OR

PERMANENT SUPPORT. PROPERLY SUPPORT ALL EXISTING ITEMS TO REMAIN. CONTRACTOR SHALL

BE RESPONSIBLE FOR PROVIDING REQUIRED SUPPORTS FOR AFFECTED ITEMS.

7. VERIFY EXTENT OF PIPING, EQUIPMENT, COMPONENTS, AND CONTROLS TO BE RETAINED OR REUSED PRIOR TO THE DEMOLITION OF SPECIFIC SYSTEM. PROTECT ITEMS WHICH ARE TO BE REUSED ON SITE TO MINIMIZE POST-CONSTRUCTION REPAIRS. ALL ITEMS WHICH ARE DAMAGED SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE REPAIRED OR REPLACED AT NO COST TO THE

CONTRACT.

8. REFER TO PLANS FOR EXISTING PIPING, DUCTWORK, EQUIPMENT, AND SYSTEM COMPONENTS TO BE

REUSED.

9. THE OWNER RETAINS FIRST RIGHT OF REFUSAL TO ALL EQUIPMENT AND SYSTEM COMPONENTS DEMOLISHED FROM THE PROJECT PRIOR TO DISPOSAL. ALL ITEMS NOT RETAINED BY THE OWNER

SHALL BE PROMPTLY AND PROPERLY DISPOSED OF OR REMOVED FROM SITE.

10. VERIFY ALL EXISTING STRUCTURAL CONDITIONS AND NOTIFY THE STRUCTURAL ENGINEER FOR

APPROVAL TO PENETRATING EXISTING BUILDING STRUCTURAL SYSTEMS.

11. NO DEMOLITION SHALL OCCUR WHICH LEAVES THE BUILDING INTERIOR WITHOUT WEATHER

PROTECTION. ALL DEMOLITION OF EXTERIOR OR EXTERIOR SURFACES SHALL BE FOLLOWED

IMMEDIATELY BY PROTECTIVE CONSTRUCTION. CONTRACTOR SHALL PROVIDE AND INSTALL

TEMPORARY PROTECTION IN ALL OPENINGS WHERE LOUVERS, WINDOWS, OR EXTERIOR DOORS HAVE

BEEN REMOVED.

12. THE DEMOLITION OF THE MECHANICAL SYSTEMS MUST BE PERFORMED TO CORRESPOND TO THE

PHASED NATURE OF THE PROJECT. REFER TO ARCHITECTURAL PHASING PLANS FOR PROJECT

PHASING. THE CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY WORK AND EQUIPMENT

NECESSARY TO KEEP REQUIRED SYSTEMS OPERATIONAL UNTIL THEY ARE NO LONGER NEEDED. THIS MAY INCLUDE BUT IS NOT LIMITED TO: RELOCATION OF EQUIPMENT AND ALL APPURTENANCES AND

CONTROLS, RE-PIPING OF EQUIPMENT, AND RE-DUCTING OF EQUIPMENT.

1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING ALL CONNECTIONS TO EXISTING AND NEW SYSTEMS AS REQUIRED TO FACILITATE PROPER CONTINUAL OPERATION OF ALL SYSTEMS AND EQUIPMENT, EXISTING OR NEW, EXCEPT WHERE IN THE CURRENT PHASE OF CONSTRUCTION.

2. THE CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY WORK AND EQUIPMENT NECESSARY TO KEEP REQUIRED SYSTEMS OPERATIONAL UNTIL THEY ARE FULLY RENOVATED AND OPERATING OR UNTIL THEY ARE NO LONGER NEEDED AND DEMOLISHED. THIS MAY INCLUDE BUT IS NOT LIMITED TO: RELOCATION OF EQUIPMENT AND ALL APPURTENANCES AND CONTROLS, RE-PIPING OF EQUIPMENT, AND RE-DUCTING OF

EQUIPMENT.

3. IF THE NEED FOR TEMPORARY SERVICE(S) OR CONNECTIONS DICTATES WORK BE DONE OUT OF PHASE, THIS WORK SHALL BE APPROVED BY THE ARCHITECT AND THE OWNER. WORK SHALL TAKE PLACE IN SUCH A MANNER SO AS NOT TO INTERFERE WITH THE DAY-TO-DAY OPERATIONS OF THE FACILITY AS DETERMINED BY

THE OWNER.

4. REFER TO THE PROJECT SPECIFICATIONS AND ARCHITECTURAL PHASING PLANS TO DETERMINE THE PHASING OF DEMOLITION AND INSTALLATION OF MECHANICAL SYSTEM COMPONENTS. ALTHOUGH PORTIONS OF A MECHANICAL SYSTEM MAY LIE OUTSIDE A PHASED AREA ON PLAN, THOSE COMPONENTS ARE CONSIDERED TO BE “IN PHASE” IF THEIR INSTALLATION AND OPERATION IS REQUIRED FOR THE OCCUPANCY AND USE OF THE PHASED AREA. ALL “IN PHASE” MECHANICAL COMPONENTS SHALL BE INSTALLED AND MADE OPERATIONAL PRIOR TO THE COMPLETION OF THAT PHASE. COORDINATE ALL PHASING REQUIREMENTS WITH

THE GENERAL CONTRACTOR’S SCHEDULE TO ENSURE CONTINUITY OF SYSTEM OPERATION.

5. THE CONTRACTOR SHALL BE AWARE THAT THE EXISTING BUILDING(S) AND ADJACENT SITE WILL BE OCCUPIED AND IN USE 24 HOURS PER DAY, 7 DAYS A WEEK. THE CONTRACTOR SHALL CONDUCT THEIR OPERATIONS SO THAT THERE WILL BE MINIMAL INTERFERENCE WITH THE CONTINUED OPERATION OF THE EXISTING BUILDING(S) AND STAFF. ANY INTERFERENCE OR INCONVENIENCE TO BUILDING OPERATIONS SHALL

BE REVIEWED WITH THE COR AND ARCHITECT PRIOR TO COMMENCEMENT.

6. CONTRACTOR SHALL MINIMIZE SHUTDOWN TIMES DURING MECHANICAL SYSTEM SWITCHOVERS. ALL

SHUTDOWN TIMES AND THEIR DURATIONS SHALL BE COORDINATED WITH THE COR.

CONSULTANTS:

Drawing Title

Approved: Project Director

Project Title:

Location:

Date: Checked: Drawn:

Drawing Number

Building Number

Project Number

Office of Construction and Facilities Management

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

FULLY SPRINKLERED

A

B

C

D

E

F

Revisions: Date0

6 " o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t

6587 Hamilton Avenue Pittsburgh, Pennsylvania 15206 Ph: 412.287.7333 Fax: 412.287.7334 www.ae-works.com

AE Works Project Number:

ARCHITECTS/ENGINEERS:SEAL

H.H. MCGUIRE VAMC -

CONSTRUCT SPINAL CORD

ENHANCEMENT CENTER

652 - 314

JKG CJC

1201 Broad Rock Boulevard, Richmond, VA 23249

M001

MECHANICAL SYMBOLS, ABBREVIATIONS AND

GENERAL NOTES

09/11/2017 13030

BID DOCUMENTS

RG-2

RG-2

RG-2

RG-2

RG-2

RG-2

RG-2

RG-2

RG-2

RG-2

RG-2

RG-4

CD-3

CD-1

EG-2

CD-5

CD-1

RG-1

CD-1

EG-2

CD-1

CD-2

EQUIPMENT STORAGE

1X-137

CLEAN LINEN

1X-138

OFFICE (NM)

1X-141

SOILED WORKROOM

1X-142

EQUIPMENT STORAGE

1X-144

CLEAN WORKROOM

1X-145

MULTI-DISCIPLINARY

WORKSTATION (MDW)

1X-147

CORRIDOR

CIX-1

ELECTRICAL ROOM

1X-131

SOILED WORKROOM

1X-136

STAFF TLT

1X-132

PATIENT LAUNDRY

1X-133

STAIR 2 (EXIST.)

1V-180

STAFF BREAK ROOM

1X-134

PRIVATE PATIENT

ROOM

1X-123

PATIENT TOILET /

SHOWER

1X-124

PRIVATE PATIENT

ROOM

1X-125

PATIENT TOILET /

SHOWER

1X-126

PRIVATE PATIENT

ROOM

1X-129

PATIENT TOILET /

SHOWER

1X-130

PRIVATE PATIENT

ROOM

1X-121

PATIENT TOILET /

SHOWER

1X-122

PRIVATE PATIENT

ROOM

1X-107

PATIENT TOILET /

SHOWER

1X-108

PRIVATE PATIENT

ROOM

1X-105

PATIENT TOILET /

SHOWER

1X-106

PRIVATE PATIENT

ROOM

1X-101

PATIENT TOILET /

SHOWER

1X-102

PRIVATE PATIENT

ROOM

1X-103

PATIENT TOILET /

SHOWER

1X-104

PRIVATE PATIENT

ROOM

1X-109

PATIENT TOILET /

SHOWER

1X-110

PRIVATE PATIENT

ROOM

1X-117

PATIENT TOILET /

SHOWER

1X-118

PRIVATE PATIENT

ROOM

1X-115

PATIENT TOILET /

SHOWER

1X-116

PRIVATE PATIENT

ROOM

1X-113

PATIENT TOILET /

SHOWER

1X-114

PRIVATE PATIENT

ROOM

1X-111

PATIENT TOILET /

SHOWER

1X-112

CROSS CORRIDOR

CIX-3

CROSS CORRIDOR

CIX-4

CORRIDOR

CIX-2

PRIVATE PATIENT

ROOM

1X-119 PATIENT TOILET /

SHOWER

1X-120

CLEAN SUPPLY

1X-139

OIT

1X-143

HAC

1X-135

NOURISHMENT

1X-140

CD-6

CD-6

EG-8

RG-2

EG-8

RG-2

RG-2

EG-8

CD-6

CD-6

CD-6

CD-6

CD-6

CD-6

CD-6

CD-6

CD-6

CD-6

CD-11

CD-6

CD-6

CD-6

CD-6

CD-6

CD-6

CD-6

CD-6

CD-6

CD-6

CD-11

EG-2

EG-1

EG-1

CD-6

CD-6

CD-11

CD-6

CD-6

CD-6

CD-6

CD-6

CD-6

EG-1

CD-1

RG-1

CD-2

RG-1

16 17 19 20

21 22 23 24

VV VV

UU UU

TT TT

SS SS

WW'

XX XX

YY YY

ZZ ZZ

20.5

20.5 21.3 22.5 23.2 24.2 24.8

YY.5 YY.5

23.8

SS.5 SS.5

SS.1 SS.1

22.8

SS.7 SS.7

TT' TT'

UU' UU'

VV' VV'

21.4

XX.3 XX.3

SS.2 SS.2

XX.6 XX.6

CD-2

CD-3

CD-3

CD-3

RG-5

CD-3

RG-4

EG-5

EG-5

CD-7

EG-5

EG-5

CD-6

RG-1

TT'.8 TT'.8

WW.8 WW.8

22.9 23.7

WW'.2 WW'.2

VV'.8 VV'.8

UU'.2 UU'.2

EG-8

CD-11

CD-11

EG-8

EG-8

CD-11

EG-4

EG-4

EG-8

CD-11

EG-8

CD-11

EG-8

CD-11

3CD-3

CD-2

CD-2

CD-2

CD-2

CD-2

CD-2

CD-2

CD-2

CD-2

CD-2

CD-2

CD-11

EG-8

CD-11

EG-8

RG-2

PRIVATE PATIENT

ROOM

1X-127

PATIENT TOILET /

SHOWER

1X-128

EF

EG-8

CD-11

CD-11

EG-8

RG-2

EG-8

CD-11

CD-3

CD-3

CD-3

CD-3

CD-2

CD-2

EG-8

CD-11

4 4 4

4 4

RG-1

CD-1

PATIENT SCALE

ALCOVE

CIX-1A

MEDICATION ROOM

1X-146

CD-1

RG-1

HVAC NOTES FOR SHEET M101

1. REFER TO FACILITY'S INFECTION CONTROL AND RISK ASSESSMENT

(ICRA) FOR ADDITIONAL REQUIREMENTS.

2. ALL WORK SHALL BE SCHEDULED AND COORDINATED JOINTLY WITH

H.H. MCGUIRE VAMC. A DETAILED JOB TIMELINE SHALL BE ESTABLISHED

AND SUBMITTED FOR REVIEW AND APPROVAL.

3. REFER TO ARCHITECTURAL FOR ADDITIONAL REQUIREMENTS. REFER

TO SHEET A121 FOR DIMENSIONED LOCATION OF DIFFUSERS, REGISTERS

AND GRILLES.

4. MAINTAIN 6" MINIMUM CLEARANCE FROM RATED WALLS AND HVAC

EQUIPMENT.

5. DIFFUSERS, REGISTERS AND GRILLES ARE FED FROM THE INTERSTITIAL

LEVEL ABOVE LEVEL ONE. REFER TO SHEET M201 FOR CONTINUATION OF

DUCTWORK. DUCTWORK PENETRATING THRU INTERSTITIAL FLOOR SLAB

(WHICH IS 1-HOUR RATED) MUST BE HARD DUCTED. REFER TO DETAIL ON

SHEET M501.

6. ALL DUCTWORK DOWNSTREAM OF VAV TERMINAL BOXES TO BE LOW

PRESSURE (3" PRESSURE CLASS). DUCTWORK UPSTREAM OF VAV

TERMINAL BOXES TO BE MEDIUM PRESSURE (6" PRESSURE CLASS).

7. CONTRACTOR TO PROVIDE REMOTE OPERATORS FOR ALL MANUAL

VOLUME DAMPERS LOCATED ABOVE GYPSUM BOARD CEILINGS.

8. RUNOUT BRANCH DUCTWORK TO SUPPLY DIFFUSERS, RETURN AND

EXHAUST GRILLES TO BE THE SAME SIZE AS THE NECK SIZE ON THE AIR

DEVICE UNLESS NOTED OTHERWISE.

9. USE ALUMINUM DUCT FOR EXHAUST FROM ROOMS WITH SHOWERS.

THE ALUMINUM DUCT SHALL EXTEND A MINIMUM OF 15 FEET FROM THE

INDIVIDUAL EXHAUST GRILLES TOWARDS THE EXHAUST FAN. USE

ALUMINUM SHEET WITH ALL JOINTS AND SEAMS SEALED WITH DUCT

SEALANT OR WELDED FOR WATER TIGHTNESS AND SLOPED DUCT BACK

TOWARDS THE GRILLE.

HVAC KEY NOTES FOR SHEET M101

1 LOCATION OF BAS CONTROL PANEL.

4" ROUND DUCT DOWN TO DRYER EXHAUST CONNECTION.

TERMINATE EXHAUST DUCT WITH UPWARD EXHAUST DIRECTION

DRYER BOX. CONTRACTOR TO COORDINATE LOCATION WITH

REQUIREMENTS OF INSTALLED DRYER.

INTERLOCK OPERATION OF IN-LINE DRYER EXHAUST FAN EF-2 WITH

DRYER OPERATION.

LOCATION OF VERTICAL DUCTWORK UP TO INTERSTITIAL SPACE

FROM FIRST FLOOR CEILING SPACE THRU FIRE RATED CEILING. ANY

UNUSED PORTION OF OPENING SHALL BE SEALED TO MAINTAIN 1-HR

RATING.

LOCATION OF CO2 SENSOR.

PARTITION TO LIMIT THE TRANSFER OF SMOKE

( NO FIRE RATING )

1-HOUR FIRE RATED PARTITION

FIRE RATED PARTITION LEGEND

2-HOUR FIRE RATED PARTITION

CONSULTANTS:

Drawing Title

Approved: Project Director

Project Title:

Location:

Date: Checked: Drawn:

Drawing Number

Building Number

Project Number

Office of Construction and Facilities Management

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

FULLY SPRINKLERED

A

B

C

D

E

F

Revisions: Date0

6 " o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t

6587 Hamilton Avenue Pittsburgh, Pennsylvania 15206 Ph: 412.287.7333 Fax: 412.287.7334 www.ae-works.com

AE Works Project Number:

ARCHITECTS/ENGINEERS:SEAL

H.H. MCGUIRE VAMC -

CONSTRUCT SPINAL CORD

ENHANCEMENT CENTER

652 - 314

JKG CJC

1201 Broad Rock Boulevard, Richmond, VA 23249

M101

MECHANICAL - LEVEL ONE - DUCTWORK

09/11/2017 13030

BID DOCUMENTS 1/8" = 1'-0"

MECHANICAL- LEVEL ONE - DUCTWORK

NORTH

PROJECT

T T

T

T

T T

T

T

T

T T

T T

T T

T

T T

T T

T T

T

T TT T

T

T TT T

T T

T T

T T

T T

T T

T

T

T

T

RCP

RCP

RCP

RCP

RCP

RCP

RCP

RCP

EQUIPMENT STORAGE

1X-137

CLEAN LINEN

1X-138

OFFICE (NM)

1X-141

SOILED WORKROOM

1X-142

EQUIPMENT STORAGE

1X-144

MULTI-DISCIPLINARY

WORKSTATION (MDW)

1X-147

CORRIDOR

CIX-1

ELECTRICAL ROOM

1X-131

SOILED WORKROOM

1X-136

STAFF TLT

1X-132

PATIENT LAUNDRY

1X-133

STAIR 2 (EXIST.)

1V-180

STAFF BREAK ROOM

1X-134

PRIVATE PATIENT

ROOM

1X-123

PATIENT TOILET /

SHOWER

1X-124

PRIVATE PATIENT

ROOM

1X-125

PATIENT TOILET /

SHOWER

1X-126

PRIVATE PATIENT

ROOM

1X-129

PATIENT TOILET /

SHOWER

1X-130

PRIVATE PATIENT

ROOM

1X-121

PATIENT TOILET /

SHOWER

1X-122

PRIVATE PATIENT

ROOM

1X-107

PATIENT TOILET /

SHOWER

1X-108

PRIVATE PATIENT

ROOM

1X-105

PATIENT TOILET /

SHOWER

1X-106

PRIVATE PATIENT

ROOM

1X-101

PATIENT TOILET /

SHOWER

1X-102

PRIVATE PATIENT

ROOM

1X-103

PATIENT TOILET /

SHOWER

1X-104

PRIVATE PATIENT

ROOM

1X-109

PATIENT TOILET /

SHOWER

1X-110

PRIVATE PATIENT

ROOM

1X-117

PATIENT TOILET /

SHOWER

1X-118

PRIVATE PATIENT

ROOM

1X-115

PATIENT TOILET /

SHOWER

1X-116

PRIVATE PATIENT

ROOM

1X-113

PATIENT TOILET /

SHOWER

1X-114

PRIVATE PATIENT

ROOM

1X-111

PATIENT TOILET /

SHOWER

1X-112

CROSS CORRIDOR

CIX-3

CROSS CORRIDOR

CIX-4

CORRIDOR

CIX-2

PRIVATE PATIENT

ROOM

1X-119

PATIENT TOILET /

SHOWER

1X-120

CLEAN SUPPLY

1X-139

OIT

1X-143

HAC

1X-135

PATIENT SCALE

ALCOVE

CIX-1A

NOURISHMENT

1X-140

16 17

19 20

21 22 23 24

VV VV

UU UU

TT TT

SS SS

WW' WW'

XX XX

YY YY

ZZ ZZ

20.5

20.5 21.3 22.5 23.2 24.2 24.8

YY.5 YY.5

23.8

SS.5

SS.1 SS.1

22.8

SS.7 SS.7

TT' TT'

UU' UU'

VV' VV'

21.4

XX.3 XX.3

SS.2 SS.2

XX.6 XX.6

RCP

RCP

RCP

RCP

RCP

RCP

23.9

TT'.8 TT'.8

WW.8 WW.8

22.9 23.7

WW'.2 WW'.2

VV'.8 VV'.8

UU'.2 UU'.2

RCP

TO RCP-15

TO VAV-2

TO VAV-16

TO VAV-17

TO RCP-1

TO VAV-1

TO VAV-19

TO VAV-20

TO VAV-25

TO RCP-2

TO VAV-3

TO RCP-3

TO VAV-5

TO VAV-21

TO VAV-22

TO VAV-23

TO VAV-26

TO VAV-27

TO RCP-4

TO VAV-7

TO RCP-5

TO VAV-9

TO VAV-28

TO VAV-29

T O

V A

V -1

T O

R C

P -6

T O

V A

V -1

T O

R C

P -7

TO VAV-18

T O

V A

V -1

T O

R C

P -8

T O

V A

V -1

T O

R C

P -9

T O

V A

V -1

T O

R C

P -1

TO RCP-11

TO VAV-10

TO RCP-12

TO VAV-8

TO RCP-13

TO VAV-6

TO RCP-14

TO VAV-4

TO VAV-24

PRIVATE PATIENT

ROOM

1X-127

PATIENT TOILET /

SHOWER

1X-128

RCP

RCP

TO RCP-16

TO RCP-17

1 1

1 1

1 1

1 1

CLEAN WORKROOM

1X-145

MEDICATION ROOM

1X-146

HVAC NOTES FOR SHEET M102

1. REFER TO FACILITY'S INFECTION CONTROL AND RISK ASSESSMENT

(ICRA) FOR ADDITIONAL REQUIREMENTS.

2. ALL WORK SHALL BE SCHEDULED AND COORDINATED JOINTLY WITH

H.H. MCGUIRE VAMC. A DETAILED JOB TIMELINE SHALL BE ESTABLISHED

AND SUBMITTED FOR REVIEW AND APPROVAL.

3. REFER TO ARCHITECTURAL FOR ADDITIONAL REQUIREMENTS.

4. MAINTAIN 6" MINIMUM CLEARANCE FROM RATED WALLS AND HVAC

EQUIPMENT.

5. ALL BRANCH PIPING IS 3/4" UNLESS OTHERWISE NOTED.

6. PROVIDE EXPANSION LOOPS, JOINTS, Z BENDS AND PIPING OFFSETS

TO ACCOMMODATE THERMAL AND OTHER PIPING MOVEMENT.

7. FOR ALL EXPOSED PIPING IN COMMUNICATION ROOMS AND

ELECTRICAL ROOMS, PROVIDE DRIP PANS UNDER INSULATED WATER

PIPING. SLOPE DRIP PAN AT END, PUT A 1/4" CONDENSATE LINE FLUSH

TO ADJACENT FINISHED CEILING & PROVIDE AN ESCUTCHEON.

HVAC KEY NOTES FOR SHEET M102

1 3/4" HWHS & HWHR PIPES (TO SERVE RADIANT CEILING PANEL) UP TO

INTERSTITIAL LEVEL. REFER TO M202 FOR CONTINUATION.

PARTITION TO LIMIT THE TRANSFER OF SMOKE

( NO FIRE RATING )

1-HOUR FIRE RATED PARTITION

FIRE RATED PARTITION LEGEND

2-HOUR FIRE RATED PARTITION

CONSULTANTS:

Drawing Title

Approved: Project Director

Project Title:

Location:

Date: Checked: Drawn:

Drawing Number

Building Number

Project Number

Office of Construction and Facilities Management

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

FULLY SPRINKLERED

A

B

C

D

E

F

Revisions: Date0

6 " o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t

6587 Hamilton Avenue Pittsburgh, Pennsylvania 15206 Ph: 412.287.7333 Fax: 412.287.7334 www.ae-works.com

AE Works Project Number:

ARCHITECTS/ENGINEERS:SEAL

H.H. MCGUIRE VAMC -

CONSTRUCT SPINAL CORD

ENHANCEMENT CENTER

652 - 314

JKG CJC

1201 Broad Rock Boulevard, Richmond, VA 23249

M102

MECHANICAL - LEVEL ONE - PIPING

09/11/2017 13030

BID DOCUMENTS

1/8" = 1'-0"

MECHANICAL- LEVEL ONE - PIPING

REFER TO SHEET

M103 VIEW #2 FOR

CONTINUATION

21 22 23 24

SS

RR

QQ

22.5 23.2

SS.1

21.4 23.922.9 23.7

3" LPS

2 1/2" LPCR

2 1/2" HWHR

2 1/2" HWHS

REFER TO M202 FOR

CONTINUATION.

REFER TO M103

VIEW #1 FOR

CONTINUATION.

4" CHWR

4" CHWS

HVAC NOTES FOR SHEET M103

1. REFER TO FACILITY'S INFECTION CONTROL AND RISK ASSESSMENT

(ICRA) FOR ADDITIONAL REQUIREMENTS.

2. ALL WORK SHALL BE SCHEDULED AND COORDINATED JOINTLY WITH

H.H. MCGUIRE VAMC. A DETAILED JOB TIMELINE SHALL BE ESTABLISHED

AND SUBMITTED FOR REVIEW AND APPROVAL.

3. REFER TO ARCHITECTURAL FOR ADDITIONAL REQUIREMENTS.

4. MAINTAIN 6" MINIMUM CLEARANCE FROM RATED WALLS AND HVAC

EQUIPMENT.

5. PROVIDE INTERMEDIARY CONDENSATE TRAPS ON HORIZONTAL STEAM

SUPPLY LINES AT LEAST EVERY 100 FEET OF HORIZONTAL RUN.

HVAC KEY NOTES FOR SHEET M103

1 NEW FLOOR PENETRATION THRU EXISTING CONCRETE IN-FILLED

STRUCTURAL OPENING. REFER TO VIEW #3 FOR CONTINUATION OF

PIPING.

LOCATION OF STEAM PRESSURE REDUCING VALVE (PRV) STATION.

MOUNT WITH SADDLE SUPPORTS AND LEGS. REFER TO DETAIL ON SHEET

M505 FOR ADDITIONAL INFORMATION.

LOCATION OF STEAM METER. REFER TO DETAIL 3 ON SHEET M505.

6" VENT TO ATMOSPHERE PIPE UP FROM PRV STATION. FOLLOW PATH OF

VENT PIPE FROM EXISTING PRV STATION IN SAME MECH ROOM UP THRU

ROOF.

NOT USED.

PIPING ROUTED THRU EXISTING FIRE RATED SHEETROCK OPENING IN

CONCRETE BLOCK WALL.

ROUTE 2-1/2"MPS, 2" LPCR, 4" CHWS AND 4" CHWR PIPING THRU EXISTING

OPENING IN CONCRETE BLOCK WALL BETWEEN BASEMENT AND

CRAWLSPACE.

NEW PENETRATION THRU EXISTING FIRE RATED WALL.

2-1/2" STEAM AND 2" CONDENSATE RETURN PIPES ROUTED UP TO

MECHANICAL ROOM ON LEVEL ONE. REFER TO VIEW #1 FOR

CONTINUATION OF PIPING. PROVIDE INVERTED BUCKET STEAM TRAP (ST-

8) AT BASE OF VERTICAL STEAM SUPPLY RISER, PIPED BACK TO PUMPED

CONDENSATE RETURN PIPE PER DETAIL 10

INSTALL TWO (2) GATE VALVES WITH MIDDLE BLEED LINE TO PROVIDE

FUTURE ABILITY TO DOUBLE BLOCK STEAM LINE (WITH MIDDLE BLEED

LINE) TO ALLOW FOR MODIFICATION TO STEAM LINE.

HOT TAP OF EXISTING STEAM LINE WHILE EXISTING STEAM LINE REMAINS

UNDER FULL OPERATING CONDITIONS USING COUPON RETENTION.

DOUBLE WIRED PILOT DRILL RETAINS THE COUPON AND IS RECOVERED

WHEN HOT TAP IS COMPLETED. TAPPING SADDLE IS PLACED AGAINST

EXISTING PIPE WITH ISOLATION VALVE AND HOT TAPPING MACHINE. AFTER

THE SADDLE IS INSTALLED, THE ISOLATION VALVE IS OPENED AND THE

CUTTER AND PILOT DRILL ADVANCE. WHEN THE CUT IS COMPLETED THE

CUTTER AND PILOT DRILL ARE RETRACTED, THE VALVE IS CLOSED AND

THE HOT TAP MACHINE IS REMOVED. PROVIDE PERRY POINT VAMC

WRITTEN NOTIFICATION OF WORK AT LEAST 10 WORKING DAYS PRIOR TO

COMMENCING WORK.

HEATING HOT WATER EXPANSION LOOP. REFER TO DETAIL 2 ON SHEET

M503 FOR SIZING REQUIREMENTS.

CHEMICAL POT FEEDER LOCATION. REFER TO DETAIL 3 ON SHEET M504.

INVERTED BUCKET STEAM TRAP ST-3 PIPED BACK TO STEAM

CONDENSATE RECEIVER/PUMP IN MECH SVC BAY 1U-144.

FLOAT & THERMOSTATIC STEAM TRAP ST-1 PIPED BACK TO STEAM

CONDENSATE RECEIVER/PUMP IN MECH SVC BAY 1U-144.

FLOAT & THERMOSTATIC STEAM TRAP ST-2 PIPED BACK TO STEAM

CONDENSATE RECEIVER/PUMP IN MECH SVC BAY 1U-144.

INVERTED BUCKET STEAM TRAP ST-9, PIPED BACK INTO PUMPED

CONDENSATE PIPE.

INVERTED BUCKET STEAM TRAP ST-10, PIPED BACK INTO PUMPED

CONDENSATE PIPE.

INVERTED BUCKET STEAM TRAP ST-7 PIPED BACK TO STEAM

CONDENSATE RECEIVER/PUMP IN MECH SVC BAY 1U-144.

4" CHWS & CHWR PIPES ROUTED UP TO MECHANICAL ROOM ON LEVEL

ONE. REFER TO VIEW #1 FOR CONTINUATION OF PIPING.

ISOLATION VALVES FOR NEW CHWS & CHWR PIPING SERVING AHU-1.

PRIOR TO START OF DEMOLITION/NEW WORK CONTRACTOR TO PROVIDE

CHILLED WATER SUPPLY AND RETURN WATER FLOW MEASUREMENT AT

THIS LOCATION AND REPORT WATER FLOW AND PIPE SIZE INFORMATION

TO ARCHITECT/ENGINEER.

UPON NEW CONSTRUCTION COMPLETION CONTRACTOR SHALL BALANCE

CHILLED WATER SUPPLY AND RETURN WATER FLOW BACK TO PRE-

DEMOLITION VALUE.

RR RR

QQ QQ

PP PP

NN NN

MM MM

LL LL

KK KK

JJ JJ

HH HH

GG GG

FF FF

EE EE

2 1/2" MPS

5" MPS (EXISTING)

(EXISTING)

2 1/2" MPS

2 1/2" MPS

2" LPCR

2" LPCR

2" LPCR

4" LPCR

4" CHWS

4" CHWR

4" CHWS

4" CHWR

4" CHWR

4" CHWS

6" CHWR

(EXISTING)

6" CHWS

(EXISTING)

22 23

22 23

22 23

QQ QQ

PP PP

1 1/4" LPCR

1 1/4" MPS

(EXISTING)

(EXISTING)

EXISTING

AIR COMPRESSOR

EXISTING AHU

500-AC41

MECH SVC BAY - R

1U-144

3" LPS

2" LPCR

REFER TO M103

VIEW #2 FOR

CONTINUATION.

HWP

HWP

4" LPS

HX

HX

1" LPCR

4" CHWR

4" CHWS

2 1/2" HWHS

2 1/2" HWHR

ET

AS

2 1/2" LPS

PRV

2 1/2" MPS

2" LPCR

2 1/2" MPS

CR

2" LPCR

14 19

4" CHWR

4" CHWS

2 1/2" CHWR

2 1/2" CHWS

(EXISTING)

(EXISTING)

EXISTING

BUILDING

NEW ADDITION

EXISTING

MECH. RM.

PARTITION TO LIMIT THE TRANSFER OF SMOKE

( NO FIRE RATING )

1-HOUR FIRE RATED PARTITION

FIRE RATED PARTITION LEGEND

2-HOUR FIRE RATED PARTITION

CONSULTANTS:

Drawing Title

Approved: Project Director

Project Title:

Location:

Date: Checked: Drawn:

Drawing Number

Building Number

Project Number

Office of Construction and Facilities Management

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

FULLY SPRINKLERED

A

B

C

D

E

F

Revisions: Date0

6 " o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t

6587 Hamilton Avenue Pittsburgh, Pennsylvania 15206 Ph: 412.287.7333 Fax: 412.287.7334 www.ae-works.com

AE Works Project Number:

ARCHITECTS/ENGINEERS:SEAL

H.H. MCGUIRE VAMC -

CONSTRUCT SPINAL CORD

ENHANCEMENT CENTER

652 - 314

JKG CJC

1201 Broad Rock Boulevard, Richmond, VA 23249

M103

MECHANICAL - EXISTING LOWER LEVEL,

LEVEL ONE AND INTERSTITIAL - PIPING

09/11/2017 13030

BID DOCUMENTS

1/8" = 1'-0"

MECHANICAL - EXISTING INTERSTITIAL - PIPING

NORTH

PROJECT

1/16" = 1'-0"

MECHANICAL - EXISTING LOWER LEVEL/CRAWLSPACE - PIPING

1/4" = 1'-0"

MECHANICAL- EXISTING MECH RM - PIPING

26"ø

24"ø

"ø

"ø

VAV

"ø

"ø

14"ø

VAV

30"x20"

"ø

"ø

"ø

14"ø

"ø

VAV

8"ø

"ø

18"ø

8"ø

"ø

"ø

"ø

8"ø

14"ø

"ø

"ø

16"ø

8"ø

8"ø

VAV

VAV

VAV

VAV

11VAV

VAV

16"ø

57"x26" RETURN

AIR UP TO AHU-1

54"x46"

SUPPLY

AIR DOWN

FROM

AHU-1

10"ø

VAV

VAV

VAV

VAV

VAV

8"ø

VAV

VAV

VAV

VAV

VAV

VAV

VAV

10"ø

12"ø 12"ø

8"ø

12"ø

"ø

10"ø

10"ø

8"ø

12"ø

10"ø

8"ø

12"ø 8"ø

8"ø

12"ø

10"ø

10"ø 12"ø

8"ø

"ø

8"ø

12"ø

8"ø

8"ø

8"ø12"ø

12"ø

8"ø

12"ø

10"ø

8"ø

12"ø

8"ø

10"ø8"ø

8"ø

12"ø

8"ø

12"ø

8"ø

VAV

8"ø

12"ø

8"ø

12"ø

10"ø

10"ø

10"ø

10"ø

10"ø

10"ø

"ø

10"ø

"ø

10"ø

10"ø

8"ø

10"ø

10"ø

10"ø

10"ø

8"ø

VAV

VAV

VAV

VAV

VAV

21 22 23

VV VV

UU UU

TT TT

SS SS

WW'

XX XX

YY YY

ZZ ZZ

20.5 21.3

22.5

22.5

23.2

23.2

24.2

24.2 24.8

YY.5 YY.5

23.8

SS.5

SS.1

22.8

SS.7

TT'

UU'

VV'

21.4

21.4

XX.3 XX.3

SS.2

XX.6 XX.6

23.9

23.9

TT'.8

WW.8

22.9

22.9

23.7

23.7

WW'.2

VV'.8

UU'.2

12"ø

16"ø

14"ø

57"x26"

54"x30"

10"ø

8"ø

8"ø

6"ø

10"ø

14"ø

8"ø

8"ø

8"ø

8"ø

8"ø

8"ø 8"ø

8"ø

8"ø

8"ø

10"ø

8"ø

8"ø

8"ø

8"ø

8"ø

8"ø

8"ø

12"ø

8"ø

8"ø

8"ø

8"ø

8"ø6"ø

8"ø

10"ø

"ø

14"ø

8"ø

10"ø

8"ø

8"ø

14"ø

8"ø

12"ø

"ø

14"ø

8"ø

8"ø

"ø

1 1

8"ø

16"ø

10"ø

12"ø12"ø

28"ø

36"x22"

42"x22"

46"x22"

12"ø

FD

FD12"ø

10"ø

16"ø

22"x8"

VAV

6"ø

6"ø

30"x10"

22"ø

"ø

VAV

"ø

"ø26"x20"

8"ø

8"ø

1 1

8"ø

8"ø

8"ø

8"ø10"ø

8"ø

1 1

10"ø

10"ø12"ø

12"ø

1 8"ø

14"ø

10"ø

10"ø

12"ø

14"ø

10"ø

8"ø

10"ø

6"ø

10"ø

8"ø

"ø

"ø

"ø

8"ø

10"ø

16"ø

"ø

"ø

"ø

"ø

10"ø

8"ø

"ø

10"ø

6"ø

12"ø

10"ø

"ø

8"ø

30"x20" 14"ø

30"x20"

8"ø

1 11

8"ø

10"ø 6"ø

10"ø

10"ø

6"ø

8"ø

8"ø

16"ø

12"ø

1 1

"ø1

"ø

7 7

16"ø

24"ø

16"ø

8"ø

HVAC NOTES FOR SHEET M201

1. REFER TO FACILITY'S INFECTION CONTROL AND RISK ASSESSMENT (ICRA)

FOR ADDITIONAL REQUIREMENTS.

2. ALL WORK SHALL BE SCHEDULED AND COORDINATED JOINTLY WITH H.H.

MCGUIRE VAMC. A DETAILED JOB TIMELINE SHALL BE ESTABLISHED AND

SUBMITTED FOR REVIEW AND APPROVAL.

3. REFER TO ARCHITECTURAL FOR ADDITIONAL REQUIREMENTS.

4. MAINTAIN 6" MINIMUM CLEARANCE FROM RATED WALLS AND HVAC

EQUIPMENT.

5. DIFFUSERS, REGISTERS AND GRILLES ARE FED DOWN FROM THE

INTERSTITIAL LEVEL TO LEVEL ONE BELOW. REFER TO SHEET M101 FOR

CONTINUATION OF DUCTWORK. DUCTWORK PENETRATING THRU

INTERSTITIAL FLOOR SLAB (WHICH IS 1-HOUR RATED) MUST BE HARD

DUCTED. REFER TO DETAIL ON SHEET M501.

6. ALL DUCTWORK DOWNSTREAM OF VAV TERMINAL BOXES TO BE LOW

PRESSURE (3" PRESSURE CLASS). DUCTWORK UPSTREAM OF VAV

TERMINAL BOXES TO BE MEDIUM PRESSURE (6" PRESSURE CLASS).

7. RUNOUT BRANCH DUCTWORK TO SUPPLY DIFFUSERS, RETURN AND

EXHAUST GRILLES TO BE THE SAME SIZE AS THE NECK SIZE ON THE AIR

DEVICE UNLESS NOTED OTHERWISE.

8. USE ALUMINUM DUCT FOR EXHAUST FROM ROOMS WITH SHOWERS. THE

ALUMINUM DUCT SHALL EXTEND A MINIMUM OF 15 FEET FROM THE

INDIVIDUAL EXHAUST GRILLES TOWARDS THE EXHAUST FAN. USE

ALUMINUM SHEET WITH ALL JOINTS AND SEAMS SEALED WITH DUCT

SEALANT OR WELDED FOR WATER TIGHTNESS AND SLOPED DUCT BACK

TOWARDS THE GRILLE.

HVAC KEY NOTES FOR SHEET M201

1 LOCATION OF VERTICAL DUCTWORK DOWN FROM INTERSTITIAL LEVEL TO

LEVEL ONE CEILING SPACE. OPENING TO BE SEALED TO MAINTAIN 1-

HOUR RATING. PROVIDE VOLUME DAMPER IN VERTICAL BEFORE DUCT

PENETRATES INTERSTITIAL FLOOR SLAB IF VOLUME DAMPER IS NOT

SHOWN IN THE HORIZONTAL OF THAT DUCTWORK BRANCH.

4" ROUND DUCT UP TO ROOF LEVEL CLOTHES DRYER DISCHARGE.

34"x 34" EA DUCT TRANSITIONS TO 38" ROUND AND CONNECTS TO EF-1

ON ROOF.

LOCATION OF VERTICAL DUCTWORK DOWN FROM INTERSTITIAL SPACE

TO FIRST FLOOR 1-HR FIRE RATED ROOM. DUCTWORK DOWNSTREAM IS

IN FIRST FLOOR CEILING SPACE. ANY UNUSED PORTION OF OPENING

SHALL BE SEALED TO MAINTAIN 1-HR RATING.

RELOCATE EXISTING DUCTWORK IN AREA INDICATED TO AS TIGHT TO

STRUCTURE AS POSSIBLE TO ALLOW PASSAGE THRU NEW DOORWAY.

COMBINATION SMOKE DETECTOR/SMOKE DAMPER.

INSTALL DUCTWORK AS TIGHT TO STRUCTURE AS POSSIBLE TO

MAXIMIZE HEADROOM ABOVE WALKWAY.

PARTITION TO LIMIT THE TRANSFER OF SMOKE

( NO FIRE RATING )

1-HOUR FIRE RATED PARTITION

FIRE RATED PARTITION LEGEND

2-HOUR FIRE RATED PARTITION

CONSULTANTS:

Drawing Title

Approved: Project Director

Project Title:

Location:

Date: Checked: Drawn:

Drawing Number

Building Number

Project Number

Office of Construction and Facilities Management

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

FULLY SPRINKLERED

A

B

C

D

E

F

Revisions: Date0

6 " o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t

6587 Hamilton Avenue Pittsburgh, Pennsylvania 15206 Ph: 412.287.7333 Fax: 412.287.7334 www.ae-works.com

AE Works Project Number:

ARCHITECTS/ENGINEERS:SEAL

H.H. MCGUIRE VAMC -

CONSTRUCT SPINAL CORD

ENHANCEMENT CENTER

652 - 314

JKG CJC

1201 Broad Rock Boulevard, Richmond, VA 23249

M201

MECHANICAL - LEVEL ONE INTERSTITIAL -

DUCTWORK

09/11/2017 13030

BID DOCUMENTS 1/8" = 1'-0"

MECHANICAL - LEVEL ONE INTERSTITIAL - DUCTWORK

VAV

VAV

VAV

VAV

13 VAV

11VAV

VAV

VAV

VAV

VAV

VAV

VAV

VAV

VAV

VAV

VAV

REFER TO SHEET

M103 VIEW #2 FOR

CONTINUATION

VAV

VAV

VAV

2 1/2" HWHS

VAV

VAV

2 1/2" HWHS

2" HWHR

2" HWHR

2 1/2" HWHR

2 1/2" HWHR

21 22 23 24

VV VV

UU UU

TT TT

SS SS

WW'

XX

YY YY

ZZ ZZ

20.5 21.3 22.5 23.2 24.2 24.8

YY.5 YY.5

23.8

SS.5 SS.5

22.8

SS.7

TT'

UU'

VV'

21.4

XX.3 XX.3

SS.2

XX.6 XX.6

VAV

VAV

VAV

23.9

TT'.8

WW.8

22.9 23.7

WW'.2

VV'.8

UU'.2

3" LPS

2 1/2" LPCR

1-1/2”“ LPS UP TO AHU-1

PIPE CABINET FOR AHU-1'S

PRE-HEAT COIL

1-1/4” LPS UP TO AHU-1

PIPE CABINET FOR AHU-1'S

HUMIDIFIER

4" CHWS/CHWR UP

TO AHU-1 PIPE

CABINET FOR AHU-1'S

COOLING COIL

4" CHWS

4" CHWR

TO RCP-1

VAV

VAV

VAV

TO RCP-2

TO RCP-3

TO RCP-4

TO RCP-5

TO RCP-6TO RCP-7TO RCP-8TO RCP-9

TO RCP-19

TO RCP-20

TO RCP-21

TO RCP-22

TO RCP-23

TO RCP-24

1 TO RCP-25

TO RCP-26

2" HWHR

2" HWHS

2" HWHS

2 1/2" HWHR

2 1/2" HWHS

VAV

2-1/2" LPCR DOWN FROM

AHU-1 PRE-HEAT COIL

VAV

2" HWHS

1 1/2" HWHR

1 1/2" HWHS

4" CHWS

4" CHWR

HVAC NOTES FOR SHEET M202

1. REFER TO FACILITY'S INFECTION CONTROL AND RISK ASSESSMENT

(ICRA) FOR ADDITIONAL REQUIREMENTS.

2. ALL WORK SHALL BE SCHEDULED AND COORDINATED JOINTLY WITH

H.H. MCGUIRE VAMC. A DETAILED JOB TIMELINE SHALL BE ESTABLISHED

AND SUBMITTED FOR REVIEW AND APPROVAL.

3. REFER TO ARCHITECTURAL FOR ADDITIONAL REQUIREMENTS.

4. MAINTAIN 6" MINIMUM CLEARANCE FROM RATED WALLS AND HVAC

EQUIPMENT.

5. ALL BRANCH PIPING IS 3/4" UNLESS OTHERWISE NOTED.

6. PROVIDE EXPANSION LOOPS, JOINTS, Z BENDS AND PIPING OFFSETS

TO ACCOMMODATE THERMAL AND OTHER PIPING MOVEMENT.

HVAC KEY NOTES FOR SHEET M202

1 3/4" HHWS & HHWR PIPE DOWN TO LEVEL ONE TO SERVE RADIANT

CEILING PANEL. REFER TO M102 FOR CONTINUATION.

HEATING HOT WATER EXPANSION LOOP. REFER TO DETAIL 2 ON

SHEET H503 FOR SIZING REQUIREMENTS.

ISOLATION BALL VALVES PROVIDED ON SUPPLY AND RETURN PIPING.

HEATING HOT WATER DIFFERENTIAL PRESSURE TRANSMITTER

LOCATION.

NOT USED.

INVERTED BUCKET STEAM TRAP ST-5 PIPED BACK TO STEAM

CONDENSATE RECEIVER/PUMP IN MECH SVC BAY 1U-144.

INVERTED BUCKET STEAM TRAP ST-6 PIPED BACK TO STEAM

CONDENSATE RECEIVER/PUMP IN MECH SVC BAY 1U-144.

INVERTED BUCKET STEAM TRAP ST-4 PIPED BACK TO STEAM

CONDENSATE RECEIVER/PUMP IN MECH SVC BAY 1U-144.

COOLING ONLY VAV BOX.

CHILLED WATER VALVE V_CHW1

CHILLED WATER VALVE V_CHW2

PIPING CROSSING BUILDING EXPANSION JOINT. PROVIDE PIPING

ACCESSORIES PER DETAIL 14 ON SHEET M501.

INSTALL PIPING AS TIGHT TO STRUCTURE AS POSSIBLE TO MAXIMIZE

HEADROOM ABOVE WALKWAY.

CAP AND BLIND FLANGE AT THIS LOCATION.

PARTITION TO LIMIT THE TRANSFER OF SMOKE

( NO FIRE RATING )

1-HOUR FIRE RATED PARTITION

FIRE RATED PARTITION LEGEND

2-HOUR FIRE RATED PARTITION

CONSULTANTS:

Drawing Title

Approved: Project Director

Project Title:

Location:

Date: Checked: Drawn:

Drawing Number

Building Number

Project Number

Office of Construction and Facilities Management

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

FULLY SPRINKLERED

A

B

C

D

E

F

Revisions: Date0

6 " o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t

6587 Hamilton Avenue Pittsburgh, Pennsylvania 15206 Ph: 412.287.7333 Fax: 412.287.7334 www.ae-works.com

AE Works Project Number:

ARCHITECTS/ENGINEERS:SEAL

H.H. MCGUIRE VAMC -

CONSTRUCT SPINAL CORD

ENHANCEMENT CENTER

652 - 314

JKG CJC

1201 Broad Rock Boulevard, Richmond, VA 23249

M202

MECHANICAL - LEVEL ONE INTERSTITIAL -

PIPING

09/11/2017 13030

BID DOCUMENTS

1/8" = 1'-0"

MECHANICAL - LEVEL ONE INTERSTITIAL - PIPING

HVAC NOTES FOR SHEET M203

1. REFER TO FACILITY'S INFECTION CONTROL AND RISK ASSESSMENT

(ICRA) FOR ADDITIONAL REQUIREMENTS.

2. ALL WORK SHALL BE SCHEDULED AND COORDINATED JOINTLY WITH

H.H. MCGUIRE VAMC. A DETAILED JOB TIMELINE SHALL BE ESTABLISHED

AND SUBMITTED FOR REVIEW AND APPROVAL.

3. REFER TO ARCHITECTURAL FOR ADDITIONAL REQUIREMENTS.

4. ALL STRUCTURAL AND MISCELLANEOUS STEEL REQUIRED TO SUPPORT

AND ANCHOR HVAC EQUIPMENT ON THE ROOF AND STRUCTURAL AND

MISCELLANEOUS STEEL REQUIRED FOR ANY ROOF PENETRATIONS

BEYOND WHAT IS INDICATED ON THE STRUCTURAL DRAWINGS IS THE

RESPONSIBILITY OF THE CONTRACTOR. THIS INCLUDES EQUIPMENT

SHOWN AS BASIS OF DESIGN ON THE CONTRACT DOCUMENTS,

EQUIVALENT EQUIPMENT, OR EQUIPMENT ACCEPTED FROM ALTERNATE

MANUFACTURERS. THE CONTRACTOR SHALL COORDINATE ALL

STRUCTURAL STEEL REQUIREMENTS.

HVAC KEY NOTES FOR SHEET M203

1 MAINTAIN 25'-0" CLEARANCE FOR OUTSIDE AIR INTAKE CLEARANCE. NO

EXHAUST OUTLETS OR PLUMBING VENTS WITHIN 25' OF OUTSIDE AIR

INTAKE.

DRYER EXHAUST VENT. TERMINATE WITH GOOSENECK PER DETAIL 12

ON SHEET M504.

16 17 19 20

21 22 23 24

VV VV

UU UU

TT TT

SS SS

WW'

XX

YY YY

ZZ ZZ

20.5 21.3 22.5 23.2 24.2 24.8

YY.5 YY.5

23.8

SS.5

SS.1

22.8

SS.7

TT'

UU'

VV'

21.4

XX.3 XX.3

SS.2

XX.6 XX.6

23.9

TT'.8

22.9 23.7

WW'.2

VV'.8

UU'.2

AHU

EF

1-1/2”“ LPS TO

AHU-1'S PRE-

HEAT COIL

1-1/4” LPS TO

AHU-1'S

HUMIDIFIER

4" CHWR

FROM AHU-1'S

COOLING COIL

4" CHWS TO

AHU-1'S

COOLING COIL

PIPING VESTIBULE

PARTITION TO LIMIT THE TRANSFER OF SMOKE

( NO FIRE RATING )

1-HOUR FIRE RATED PARTITION

FIRE RATED PARTITION LEGEND

2-HOUR FIRE RATED PARTITION

CONSULTANTS:

Drawing Title

Approved: Project Director

Project Title:

Location:

Date: Checked: Drawn:

Drawing Number

Building Number

Project Number

Office of Construction and Facilities Management

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

FULLY SPRINKLERED

A

B

C

D

E

F

Revisions: Date0

6 " o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t

6587 Hamilton Avenue Pittsburgh, Pennsylvania 15206 Ph: 412.287.7333 Fax: 412.287.7334 www.ae-works.com

AE Works Project Number:

ARCHITECTS/ENGINEERS:SEAL

H.H. MCGUIRE VAMC -

CONSTRUCT SPINAL CORD

ENHANCEMENT CENTER

652 - 314

JKG CJC

1201 Broad Rock Boulevard, Richmond, VA 23249

M203

MECHANICAL - ROOF LEVEL - DUCTWORK

AND PIPING

09/11/2017 13030

BID DOCUMENTS

NORTH

PROJECT

1/8" = 1'-0"

MECHANICAL - ROOF LEVEL - DUCTWORK AND PIPING

VALVE V_CHW1VALVE V_CHW2

AHU-1 COOLING

CHWS

FROM CAMPUS

CHILLED WATER

SYSTEM

CHWR

TO CAMPUS

CHILLED WATER

SYSTEM

TWO (2) GATE VALVES WITH

MIDDLE BLEED LINE FOR

DOUBLE BLOCK OF STEAM LINE

FOR STEAM LINE HOT TAP OF

EXISTING SYSTEM

HWR HWR

H W S

H W R

HWR

HWS

HWS

ST-10ST-9

ST-7

ST-8

ST-4

HWP-2

HWP-1

ST-6AHU-1 HUMIDIFIER

ST-5AHU-1 HEATING

ST-3

ST-1ST-2

HX-2 HX-1

ET-1

AS-1

50 PSIG15 PSIG

PRV-2

50 PSIG15 PSIG

PRV-1

CR-1

SFM-1

FROM EXISTING

CAMPUS STEAM

SUPPLY

SYSTEM

TO EXISTING

CAMPUS STEAM

CONDENSATE

SYSTEM

RADIANT

PANELS

(TYP. 17)

VAV

BOXES

(TYP. 29)

L P

C R

LPS

LPCR

CONSULTANTS:

Drawing Title

Approved: Project Director

Project Title:

Location:

Date: Checked: Drawn:

Drawing Number

Building Number

Project Number

Office of Construction and Facilities Management

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

FULLY SPRINKLERED

A

B

C

D

E

F

Revisions: Date0

6 " o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t

6587 Hamilton Avenue…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it.