SCI Expansion, 652-314 (VA-17-900410) Federal contract opportunity
Solicitation number
36C24618R0135
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6

About this file

36C24618R0135 SCI DWGS 05.pdf

View the file

Other files for this federal contract opportunity

Other files attached to SCI Expansion, 652-314 (VA-17-900410), newest first.
File Type Posted
36C24618R0135-00003000.docx DOCX document
36C24618R0135-00002001.pdf PDF
36C24618R0135-00002000.docx DOCX document
36C24618R0135-002.docx DOCX document
36C24618R0135-016.pdf PDF
36C24618R0135-010.pdf PDF
36C24618R0135-006.docx DOCX document
36C24618R0135-012.pdf PDF
36C24618R0135-003.docx DOCX document
36C24618R0135-014.pdf PDF
36C24618R0135-009.pdf PDF
36C24618R0135-017.pdf PDF
36C24618R0135-007.docx DOCX document
36C24618R0135-001.docx DOCX document
36C24618R0135-015.pdf PDF
36C24618R0135-011.pdf PDF
36C24618R0135-005.docx DOCX document
36C24618R0135-008.pdf PDF
36C24618R0135-004.docx DOCX document
36C24618R0135-000.docx DOCX document
Show all 20

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

T T

T

T

T T

T

T

T

T T

T T

T T

T

T T

T T

T T

T

T TT T TT TT T

T T

T T

T T

T T

T T

T

T

T

T

FIRE PROTECTION GENERAL NOTES

ALL WORK SHOWN IS NEW UNLESS INDICATED OTHERWISE.

COORDINATE ALL WORK WITH OTHER TRADES AND EXISTING CONDITIONS PRIOR TO THE FABRICATION OR INSTALLATION OF ANY PIPING.

THE DRAWINGS ARE DIAGRAMMATIC. THE CONTRACTOR MUST FIELD VERIFY ACTUAL CONDITIONS AT THE SITE PRIOR TO PROCEEDING WITH THE WORK. CONTRACTOR IS TO PROVIDE A COMPLETE SYSTEM INCLUDING ALL APPURTANCES, VALVES, AND AUXILIARY DRAINS.

ALL EXISTING SERVICES ARE SHOWN IN THEIR APPROXIMATE LOCATIONS.

ALL NEW PIPING SHALL BE INSTALLED IN SUCH A WAY THAT IT DOES NOT HAMPER ACCESS TO NEW OR EXISTING VALVES, ACCESS DOORS OR

EQUIPMENT.

SPRINKLER PIPING SHALL BE HYDRAULICALLY DESIGNED BY THE SPRINKLER CONTRACTOR AND SHALL BE APPROVED BY ALL AUTHORITIES HAVING JURISDICTION. VELOCITIES OF WATER IN HYDRAULICALLY DESIGNED SPRINKLER PIPING SHALL NOT EXCEED TWENTY FEET PER SECOND.

ALL SPRINKLER HEADS INSTALLED IN LAY-IN CEILINGS SHALL HAVE THE HEADS LOCATED IN THE CENTER OF TILES. IF FOR ANY REASON HEADS CANNOT BE LOCATED IN THE CENTER OF TILES, THEN THE ARCHITECT/ENGINEER SHALL BE CONTACTED FOR NEW LOCATIONS BEFORE INSTALLING

ANY HEAD OR PIPING.

CONTRACTOR SHALL INCLUDE IN HIS BID A WATER FLOW TEST/FIRE PUMP TEST. THE RESULTS OF WHICH SHALL BE USED TO PERFORM HYDRAULIC

CALCULATIONS.

ENTIRE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 13 2013 EDITION.

ALL WORK SHALL BE STRICTLY COORDINATED AMONG ALL INDIVIDUAL CONTRACTORS BEFORE ANY WORK IS PERFORMED.

DO NOT ROUTE PIPING THROUGH ELEVATOR SHAFT(S), ELEVATOR EQUIPMENT ROOM(S) & ELECTRICAL ROOMS, PIPING TO TERMINATE AT SPRINKLER

HEAD.

PIPES 2-1/2" & LARGER TO BE SCHEDULE 10 STEEL PIPE WITH GROOVED END PREP.

PIPES 2" & SMALLER TO SCHEDULE 40 STEEL PIPE WITH THREADED END PREP OR AS NEEDED.

PIPES TO BE SIZED PER HYDRAULIC CALCULATIONS.

VERIFY ALL CEILING HEIGHTS AT SITE PRIOR TO INSTALLATION. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF CEILINGS AND CEILING

TYPES.

IN ROOMS WHICH ARE INDICATED AS BEING MECHANICAL AND ELECTRICAL ROOMS, THE SPRINKLER CONTRACTOR SHALL COORDINATE THE LOCATION OF HIS PIPING AND SPRINKLER HEADS TO AVOID INSTALLATION OVER ELECTRICAL PANELS OR EQUIPMENT. PROVIDE ADDITIONAL SPRINKLER HEADS AS NECESSARY, AT NO ADDITIONAL COST TO THE OWNER. REFER TO HVAC AND ELECTRICAL DRAWINGS.

DESIGN DENSITIES: A. LIGHT HAZARD: .10/1500 ALL AREAS.

B. ORDINARY HAZARD: .15/1500 - STORAGE / MECHANICAL ROOMS

FIRE PROTECTION HYDRAULIC CALCULATIONS FOR AUTOMATIC SPRINKLER SYSTEMS SHALL INCORPORATE A MINIMUM 10% SAFETY FACTOR.

PRESSURE TEST OF THE AUTOMATIC SPRINKLER SYSTEM SHALL BE WITNESSED BY THE FIRE DEPARTMENT UNLESS SPECIFICALLY WAIVED. TWO (2)

WEEKS WRITTEN ADVANCE NOTICE OF TEST SHALL BE GIVEN.

FIRE PROTECTION CONTRACTOR SHALL COORDINATE HIS WORK WITH MECHANICAL, ELECTRICAL AND ALL OTHER DISCIPLINES TO AVOID INTERFERENCES PRIOR TO FABRICATION OF ANY PIPE. INTERFERENCES SHALL INCLUDE ROOF OPENINGS, BUS DUCTS, GANGED CONDUIT, DUCT, RUNS, ETC.

ALL PIPE PENETRATIONS THROUGH FLOORS OR WALLS SHALL BE SLEEVED AND SEALED TO MAKE WATERTIGHT AND MAINTAIN FIRE RATING.

CONTRACTOR TO PROPERLY CLEAN AND SEAL FULL THICKNESS OF THE PENETRATION WITH AN APPROVED FIRE STOP SYSTEM OF EQUAL OR

GREATER FIRE RESISTANCE.

ALL VALVE SUPERVISORY SWITCHES AND WATER FLOW SWITCHES SHALL BE PROVIDED AND INSTALLED BY THE FIRE PROTECTION CONTRACTOR AND

WIRED BY THE ELECTRICAL CONTRACTOR.

FIRE PROTECTION CONTRACTOR SHALL BE CERTIFIED BY STATE OF VIRGINIA FOR SPRINKLER SYSTEM INSTALLATION.

ENTIRE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH VA FIRE PROTECTION DESIGN MANUAL - SEVENTH EDITION - SEPTEMBER 2015

SPRINKLER SYSTEM TO BE INSTALLED TO ACCOMODATE SYSTEM DRAINAGE, CONTRACTOR TO PROVIDE ALL AUXILIARY DRAINS AS NECCESSARY.

CONTRACTOR TO PROVIDE 14-DAT NOTICE TO VA FOR ALL SHUTDOWNS.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

22.

23.

24.

25.

26.

SYMBOL

MANUFACTURER

OR APPROVED EQUAL

TYPE MODEL ORIFICE

TEMP. RATING

(°F)

SPRINKLER HEAD LEGEND

1/2"

HORIZON

MICROFAST

MODEL M

UPRIGHT W/ GUARD

SEMI-RECESSED, QUICK RESPONSE

VIKING

VIKING 1/2"

FROM REMOTE SPRINKLER BRANCH LINE

1"

PIPE SHALL BE SOLIDLY SUPPORTED

TO PREVENTANY MOVEMENT.

5'-0" MINIMUM CENTER

5'-0" ABOVE FINISHED FLOOR

MOUNT TEST VALVE IN EASILY

ACCESSIBLE LOCATION SUCH THAT

VALVE CAN BE WORKED ON THE FLOOR.

PROVIDE SIGNAGE AS PER N.F.P.A. 13.

SIGN SHALL ALSO DESIGNATE AREA

BEING TESTED

PROVIDE BALL VALVE WITH

LOCKABLE HANDLE

SMOOTH BORE CORROSION

RESISTANT OUTLET GIVING FLOW

EQUIVALENT TO ONE SPRINKLER HEAD.

SEE PLANS FOR DISCHARGE

LOCATIONS

NOTE:

THE ENTIRE INSTALLATION SHALL

COMPLY WITH N.F.P.A. 13

STANDPIPE RISER - XR

CONNECT TO EXISTING

EXTEND DRAIN DOWN IN STAIRWELL

NEXT TO STANDPIPE.

TO DRAIN

2"

2"

2"

2"

UNION WITH CORROSION

RESISTANT ORIFICE GIVING

FLOW EQUIVALENT TO THE

SMALLEST SPRINKLER ORIFICE

IN THE SYSTEM

SIGHT GLASS

PIPE SHALL BE SOLIDLY

SUPPORTED TO PREVENT

ANY MOVEMENT

SECTIONAL DRAIN VALVE

TEST VALVE TO BE LOCATED IN EASILY

ACCESSIBLE LOCATION WHICH CAN BE

WORKED BY STANDING ON THE FLOOR.

PROVIDE SIGNAGE AS PER N.F.P.A. 13

TO SPRINKLER SYSTEM

SPRINKLER MAIN

WATERFLOW

INDICATOR

SWITCH

PRESSURE GAUGE

CHECK VALVE

INDICATING CONTROL VALVE

WITH SUPERVISORY SWITCH

BRANCH MAIN

1"

CEILING TILE

1" x 1/2" REDUCER

SEMI-RECESSED SPRINKLER

CEILING TILE

CEILING TILE

THESE DIMENSIONS VARY

TO PLACE SPRINKLERS IN

CENTER OF CEILING TILE

VARIES VARIES

SPRINKLER ZONE - 1 - FIRST FLOOR BUILDING ADDITION

VV VV

UU UU

TT TT

SS SS

WW'

XX

YY

ZZ

20.5 21.3 22.5 23.2 24.2 24.8

YY.5

23.8

SS.5 SS.5

SS.1 SS.1

22.8

SS.7

TT'

UU'

VV'

21.4

XX.3

SS.2

XX.6

23.9

TT'.8

WW.8

22.9 23.7

WW'.2

VV'.8

UU'.2

1 2

FIRE PROTECTION SYMBOLS

F

D

FIRE LINE

SEMI-RECESSED SPRINKLER

UPRIGHT SPRINKLER W/ GUARD

ZONE CONTROL VALVE

RISE

DROP

CAP

KEYED NOTE DESCRIBING WORK TO BE DONE

TAMPER SWITCH

FIRE DEPARTMENT HOSE VALVEFDHV

CONNECT TO EXISTING PIPING THIS POINT

DRAIN LINE

EXISTING TO REMAINXR

TYPICAL PIPE HANGER DETAIL

BOTTOM

BEAM

C-CLAMP

TRAPEZE PIPE SIZE

PER NFPA

CONNECTIONS ON SPRINKLER SHOP DRAWINGS. INSTALLATION

AND LOCATION OF ALL SWAY BRACING AND FLEXIBLE PIPE

FIRE PROTECTION CONTRACTOR SHALL INDICATE HANGER TYPE

SHALL BE IN ACCORDANCE WITH NFPA 13

NOTE

RISER CLAMP

GALVANIZED

SWIVEL RING

HANGER

GALVANIZED

DOUBLE RING

HANGER

TIGHTEN

RODS

AGAINST PIPE

(TYP)

GALVANIZED

DOUBLE RING

HANGER

BEAM

TOP

BEAM

C-CLAMP

RETAINER CLAMP

(TYP EA END)

JOIST / BEAM

BOTTOM

BEAM CLAMP

TIGHTEN

RODS

AGAINST PIPE

C-CLAMP

TRAPEZE PIPE

PER NFPA

ROOF SLOPE

SWIVEL RING

PURLIN

PURLIN C-CLAMP

CONSULTANTS:

Drawing Title

Approved: Project Director

Project Title:

Location:

Date: Checked: Drawn:

Drawing Number

Building Number

Project Number

Office of Construction and Facilities Management

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

FULLY SPRINKLERED

A

B

C

D

E

F

Revisions: Date0

6 " o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t

6587 Hamilton Avenue Pittsburgh, Pennsylvania 15206 Ph: 412.287.7333 Fax: 412.287.7334 www.ae-works.com

AE Works Project Number:

ARCHITECTS/ENGINEERS:SEAL

H.H. MCGUIRE VAMC -

CONSTRUCT SPINAL CORD

ENHANCEMENT CENTER

652 - 314

MEW MEW

1201 Broad Rock Boulevard, Richmond, VA 23249

F001

FIRE PROTECTION - SYMBOLS, NOTES &

DETAILS

09/11/2017 13030

BID DOCUMENTS

NTS

SPRINKLER INSPECTOR'S TEST DRAIN DETAIL

NTS

STANDPIPE CONNECTION DETAIL

NTS

TYPICAL SEMI-RECESSED SPRINKLER DETAIL

1/16" = 1'-0"

FIRE PROTECTION ZONE PLAN - FIRST FLOOR

NTS

SWAY BRACING DETAIL

NORTH

PROJECT

S/R

6"-STAND PIPE

-XR

SPRINKLER

CONTROL VALVE

WATER FLOW

AND TAMPER

SWITCH

PIPING

ABOVE

THIS

CEILING

PIPING

ABOVE

THIS

CEILING

PIPING ABOVE

THIS CEILING

PIPING ABOVE

THIS CEILING

PIPING

ABOVE

THIS

CEILING

PIPING ABOVE

THIS CEILING

VV VV

UU UU

TT TT

SS SS

WW'

XX

YY

ZZ

20.5 21.3 22.5 23.2 24.2 24.8

YY.5

23.8

SS.5 SS.5

SS.1 SS.1

22.8

SS.7

TT'

UU'

VV'

21.4

XX.3

SS.2

XX.6

23.9

TT'.8

WW.8

WW'.2

VV'.8

UU'.2

S P

R S

P R

S P

R S

P R

S P

R S

P R

4 BED RM - LODGER

1V-130

P R

IV

A

T E

P A

T

IE

N T

R O

O M

1X -1

PRIVATE PATIENT

ROOM

1X-119

PATIENT TOILET /

SHOWER

1X-120

P A

T

IE

N T

T O

IL

E

T

S H

O W

E R

1X -1

P A

T

IE

N T

T O

IL

E

T

S H

O W

E R

1X -1

P R

IV

A

T E

P A

T

IE

N T

R O

O M

1X -1

P R

IV

A

T E

P A

T

IE

N T

R O

O M

1X -1

P A

T

IE

N T

T O

IL

E

T

S H

O W

E R

1X -1

P A

T

IE

N T

T O

IL

E

T

S H

O W

E R

1X -1

PRIVATE PATIENT

ROOM

1X-111

PATIENT TOILET /

SHOWER

1X-110

PRIVATE PATIENT

ROOM

1X-109

OIT

1X-143

EQUIPMENT STORAGE

1X-144

SOILED WORKROOM

1X-142

CROSS CORRIDOR

CIX-4

CORRIDOR

CIX-1

PATIENT TOILET /

SHOWER

1X-106

PATIENT TOILET /

SHOWER

1X-108

CLEAN LINEN

1X-138

CLEAN SUPPLY

1X-139

OFFICE (NM)

1X-141

NOURISHMENT

1X-140

PRIVATE PATIENT

ROOM

1X-105

PRIVATE PATIENT

ROOM

1X-103

PATIENT TOILET /

SHOWER

1X-104

PATIENT TOILET /

SHOWER

1X-102

PRIVATE PATIENT

ROOM

1X-101

PATIENT LAUNDRY

1X-133

STAFF TLT

1X-132

STAFF BREAK ROOM

1X-134

HAC

1X-135

CORRIDOR

CIX-1

ELECTRICAL ROOM

1X-131

C O

R R

ID

O

R

C

IX

-2

PRIVATE PATIENT

ROOM

1X-129

PATIENT TOILET /

SHOWER

1X-130

CROSS CORRIDOR

CIX-3

EQUIPMENT STORAGE

1X-137

SOILED WORKROOM

1X-136

CORRIDOR

CIX-2

PRIVATE PATIENT

ROOM

1X-125

PATIENT TOILET /

SHOWER

1X-126

PATIENT TOILET /

SHOWER

1X-124

PRIVATE PATIENT

ROOM

1X-123

CORRIDOR

CIX-2

CORRIDOR

CIX-1

PRIVATE PATIENT

ROOM

1X-121

PATIENT TOILET /

SHOWER

1X-122

MULTI-DISCIPLINARY

WORKSTATION (MDW)

1X-147

PATIENT TOILET /

SHOWER

1X-128

INSPECTORS

TEST

CONNECTION

S P

R

SPR

SPR

SPR

SPR

S P

R

SPR

SPR

SPR

SPR

SPR

SPR

SPR

SPR

SPR

SPR

S P

R S

P R

SPR

SPR

SPR

S P

R

SPR

S P

RSPR

SPR

SPR

S P

R

SPR

SPR

S P

R

SPR

SPR

S P

R

SPR

SPR

SPRSPR

S P

R

S P

R

S P

R

SPR

SPR

SPR

SPR

SPR

SPR

SPR

CHECK VALVE

S P

R

S P

R

S P

R S P

R

S P

R S

P R

S P

R S

P R

CLEAN WORKROOM

1X-145

MEDICATION ROOM

1X-146

PARTITION TO LIMIT THE TRANSFER OF SMOKE

( NO FIRE RATING )

1-HOUR FIRE RATED PARTITION

FIRE RATED PARTITION LEGEND

2-HOUR FIRE RATED PARTITION

CONSULTANTS:

Drawing Title

Approved: Project Director

Project Title:

Location:

Date: Checked: Drawn:

Drawing Number

Building Number

Project Number

Office of Construction and Facilities Management

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

FULLY SPRINKLERED

A

B

C

D

E

F

Revisions: Date0

6 " o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t

6587 Hamilton Avenue Pittsburgh, Pennsylvania 15206 Ph: 412.287.7333 Fax: 412.287.7334 www.ae-works.com

AE Works Project Number:

ARCHITECTS/ENGINEERS:SEAL

H.H. MCGUIRE VAMC -

CONSTRUCT SPINAL CORD

ENHANCEMENT CENTER

652 - 314

MEW MEW

1201 Broad Rock Boulevard, Richmond, VA 23249

F101

FIRE PROTECTION FLOORPLAN- LEVEL ONE

09/11/2017 13030

BID DOCUMENTS 1/8" = 1'-0"

FIRE PROTECTION FLOORPLAN- LEVEL ONE

NORTH

PROJECT

NOTE:

REFER TO ARCHITECTURAL DRAWING A401 DETAIL 2, FOR TYPICAL

PATIENT ROOM REFLECTED CEILING LAYOUT. HEAD LAYOUT TO BE

TYPICAL PER THIS DETAIL.

F001 - FIRE PROTECTION - SYMBOLS, NOTES & DETAILS
Sheets
E001 - ELECTRICAL SYMBOLS, ABBREVIATIONS AND NOTES
E100 - ELECTRICAL - BUILDING OVERALL PLAN
E101 - ELECTRICAL SITE PLAN - NEW WORK
E200 - ELECTRICAL - LEVEL ONE - LIGHTING
E201 - ELECTRICAL - LEVEL ONE INTERSTITIAL - LIGHTING
E300 - ELECTRICAL - LEVEL ONE - POWER
E301 - ELECTRICAL - LEVEL ONE INTERSTITIAL - POWER
E302 - ELECTRICAL - ROOF LEVEL - POWER AND LIGHTNING PROTECTION PLAN
E400 - ELECTRICAL ENLARGED PLAN - TYPICAL PATIENT ROOM - POWER
E500 - LIGHTING DETAILS & SCHEDULES
E501 - ELECTRICAL DETAILS
E502 - ELECTRICAL DETAILS
E600 - ELECTRICAL - RISER DIAGRAM
E610 - ELECTRICAL SINGLE LINE DIAGRAM
E700 - ELECTRICAL PANEL SCHEDULES
E701 - ELECTRICAL PANEL SCHEDULES
ED100 - ELECTRICAL SITE PLAN - DEMOLITION
EF001 - SYSTEMS - SYMBOLS AND NOTES - FIRE ALARM
EF200 - SYSTEMS - LEVEL ONE - FIRE ALARM
EF201 - SYSTEMS - LEVEL ONE INTERSTITIAL - FIRE ALARM
ET001 - SYSTEMS - SYMBOLS AND NOTES - TELECOMMUNICATIONS
ET200 - SYSTEMS - LEVEL ONE - TELEDATA
ET201 - SYSTEMS - LEVEL ONE INTERSTITIAL - TELECOM
ET500 - SYSTEMS - DETAILS
F001 - FIRE PROTECTION - SYMBOLS, NOTES & DETAILS
F101 - FIRE PROTECTION FLOORPLAN- LEVEL ONE
M001 - MECHANICAL SYMBOLS, ABBREVIATIONS AND GENERAL NOTES
M101 - MECHANICAL - LEVEL ONE - DUCTWORK
M102 - MECHANICAL - LEVEL ONE - PIPING
M103 - MECHANICAL - EXISTING LOWER LEVEL, LEVEL ONE AND INTERSTITIAL - PIPING
M201 - MECHANICAL - LEVEL ONE INTERSTITIAL - DUCTWORK
M202 - MECHANICAL - LEVEL ONE INTERSTITIAL - PIPING
M203 - MECHANICAL - ROOF LEVEL - DUCTWORK AND PIPING
M401 - MECHANICAL PIPING DIAGRAMS
M501 - MECHANICAL DETAILS
M502 - MECHANICAL DETAILS
M503 - MECHANICAL DETAILS
M504 - MECHANICAL DETAILS
M505 - MECHANICAL DETAILS
M601 - MECHANICAL CONTROLS
M602 - MECHANICAL CONTROLS
M701 - MECHANICAL SCHEDULES
M702 - MECHANICAL SCHEDULES
P001 - PLUMBING - SYMBOLS, SCHEDULES & NOTES
P100A - PLUMBING FLOORPLAN - LOWER LEVEL AND LEVEL ONE TAP IN
P100B - PLUMBING FLOORPLAN - LOWER LEVEL - AREA 'B' & 'C'
P100U - PLUMBING FLOORPLAN - UNDER FLOOR
P101A - PLUMBING FLOORPLAN - LEVEL ONE - PART 'A'
P101B - PLUMBING FLOORPLAN - LEVEL ONE - PART 'B'
P101C - PLUMBING FLOORPLAN - LEVEL ONE - PART 'C'
P102A - PLUMBING FLOORPLAN - LEVEL ONE INTERSTITAL - PART 'A'
P102B - PLUMBING FLOORPLAN - LEVEL ONE INTERSTITAL - PART 'B'
P103 - PLUMBING FLOORPLAN- ROOF LEVEL
P201 - PLUMBING DETAILS
P202 - PLUMBING DETAILS
P301 - PLUMBING ISOMETRIC RISER - SANITARY, VENT AND STORM
P302 - PLUMBING RISER - DOMESTIC WATER AND MEDICAL GASES
F101 - FIRE PROTECTION FLOORPLAN- LEVEL ONE
Sheets
E001 - ELECTRICAL SYMBOLS, ABBREVIATIONS AND NOTES
E100 - ELECTRICAL - BUILDING OVERALL PLAN
E101 - ELECTRICAL SITE PLAN - NEW WORK
E200 - ELECTRICAL - LEVEL ONE - LIGHTING
E201 - ELECTRICAL - LEVEL ONE INTERSTITIAL - LIGHTING
E300 - ELECTRICAL - LEVEL ONE - POWER
E301 - ELECTRICAL - LEVEL ONE INTERSTITIAL - POWER
E302 - ELECTRICAL - ROOF LEVEL - POWER AND LIGHTNING PROTECTION PLAN
E400 - ELECTRICAL ENLARGED PLAN - TYPICAL PATIENT ROOM - POWER
E500 - LIGHTING DETAILS & SCHEDULES
E501 - ELECTRICAL DETAILS
E502 - ELECTRICAL DETAILS
E600 - ELECTRICAL - RISER DIAGRAM
E610 - ELECTRICAL SINGLE LINE DIAGRAM
E700 - ELECTRICAL PANEL SCHEDULES
E701 - ELECTRICAL PANEL SCHEDULES
ED100 - ELECTRICAL SITE PLAN - DEMOLITION
EF001 - SYSTEMS - SYMBOLS AND NOTES - FIRE ALARM
EF200 - SYSTEMS - LEVEL ONE - FIRE ALARM
EF201 - SYSTEMS - LEVEL ONE INTERSTITIAL - FIRE ALARM
ET001 - SYSTEMS - SYMBOLS AND NOTES - TELECOMMUNICATIONS
ET200 - SYSTEMS - LEVEL ONE - TELEDATA
ET201 - SYSTEMS - LEVEL ONE INTERSTITIAL - TELECOM
ET500 - SYSTEMS - DETAILS
F001 - FIRE PROTECTION - SYMBOLS, NOTES & DETAILS
F101 - FIRE PROTECTION FLOORPLAN- LEVEL ONE
M001 - MECHANICAL SYMBOLS, ABBREVIATIONS AND GENERAL NOTES
M101 - MECHANICAL - LEVEL ONE - DUCTWORK
M102 - MECHANICAL - LEVEL ONE - PIPING
M103 - MECHANICAL - EXISTING LOWER LEVEL, LEVEL ONE AND INTERSTITIAL - PIPING
M201 - MECHANICAL - LEVEL ONE INTERSTITIAL - DUCTWORK
M202 - MECHANICAL - LEVEL ONE INTERSTITIAL - PIPING
M203 - MECHANICAL - ROOF LEVEL - DUCTWORK AND PIPING
M401 - MECHANICAL PIPING DIAGRAMS
M501 - MECHANICAL DETAILS
M502 - MECHANICAL DETAILS
M503 - MECHANICAL DETAILS
M504 - MECHANICAL DETAILS
M505 - MECHANICAL DETAILS
M601 - MECHANICAL CONTROLS
M602 - MECHANICAL CONTROLS
M701 - MECHANICAL SCHEDULES
M702 - MECHANICAL SCHEDULES
P001 - PLUMBING - SYMBOLS, SCHEDULES & NOTES
P100A - PLUMBING FLOORPLAN - LOWER LEVEL AND LEVEL ONE TAP IN
P100B - PLUMBING FLOORPLAN - LOWER LEVEL - AREA 'B' & 'C'
P100U - PLUMBING FLOORPLAN - UNDER FLOOR
P101A - PLUMBING FLOORPLAN - LEVEL ONE - PART 'A'
P101B - PLUMBING FLOORPLAN - LEVEL ONE - PART 'B'
P101C - PLUMBING FLOORPLAN - LEVEL ONE - PART 'C'
P102A - PLUMBING FLOORPLAN - LEVEL ONE INTERSTITAL - PART 'A'
P102B - PLUMBING FLOORPLAN - LEVEL ONE INTERSTITAL - PART 'B'
P103 - PLUMBING FLOORPLAN- ROOF LEVEL
P201 - PLUMBING DETAILS
P202 - PLUMBING DETAILS
P301 - PLUMBING ISOMETRIC RISER - SANITARY, VENT AND STORM
P302 - PLUMBING RISER - DOMESTIC WATER AND MEDICAL GASES