This document is a lead paint screening report conducted by Aerosol Monitoring & Analysis, Inc. (AMA) for the United States Department of Veterans Affairs Perry Point Campus in Maryland. Between September 30 and October 31, 2013, AMA representatives performed a comprehensive lead-containing materials (LCM) screening across 50 buildings totaling 1,103,000 square feet, with construction dates ranging from 1750 to the present.
Using an x-ray fluorescence (XRF) analyzer, the team tested multiple surfaces and components for lead concentrations, identifying numerous buildings with lead-containing materials in various conditions. The report highlights significant and isolated areas of damaged lead paint across different building types, including administrative, medical, psychiatric, and support facilities. Key findings include lead concentrations exceeding 0.7 mg/cm² in components like plaster walls and ceilings, metal structures, wood surfaces, and architectural elements. The documentation provides detailed guidance for contractors on handling lead-containing materials, emphasizing the need for proper testing, disposal, and worker protection in accordance with OSHA standards and environmental regulations.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
United States Department of Veterans Affairs
Perry Point Campus
Lead Paint Screening
Environmental Consultants
1331 Ashton Road P.O. Box 646 Hanover, MD 21076 410-684-3327 FAX: 410-684-3384 www.amaconsulting.com
November 13, 2013
Mr. Robert Deinert Safety/Occupational Health Program Manager VA Maryland Healthcare System Perry Point VA Medical Center Bldg. 101, Room 31 Perryville, MD 21902
RE: United States Department of Veteran Affairs VISN 5 Contract No. GS-10F-
0386K Lead Paint Screening for the Veterans Affairs Perry Point Campus
Bldg: Perry Point Campus
AMA Project #: 13404
Mr. Deinert:
Between September 30 and October 31st, 2013 Aerosol Monitoring & Analysis, Inc. (AMA) representatives, Mr. Andrew Washington, Mr. Patrick Dincher, Mr.
Adam Truax, Mr. Rob Schoennagel, Mr. Kinte Thompson, and Mr. Ron Stallard conducted an onsite lead paint screening of the Perry Point VAMC campus facilities for the purpose of identifying lead containing materials within the buildings.
Background Information
Perry Point Campus Perry Point, MD 21902
1,103,000 square feet for inspection
Total Buildings: 50 (including connecting corridors)
Original Construction Dates: Various dates ranging from 1918 – Present (Mansion constructed in 1750)
Renovations Dates: Various dates on select buildings ranging from 1968 - Present
Existing Lead Documentation – None to be relied upon
Buildings inspected by AMA:
(24H) Mental Health (1H) Domiciliary (25H) Mental Health (2H) Domiciliary (26) Fire House (3H) Administration (27H) Biomedical Shop
(4) Research (41) Greenhouse
(4H) IRMS (59)
(5H) Director’s Office (80H) Mental Health Clinic
(5) Stock Storage (82) Education/Research (6H) Voluntary Service (97) Gatehouse
(8) Engineering Storage (101) Administration (9H) Nursing Home (102) Filter Plant
(11) Warehouse (314A) Theater (11H) Human Resources (314B) Recreation (13H) Psychiatric Units (314C) Chapel
(13) Public Health Service (315) Boiler Plant (14H) Psychiatric Units (321) Chiller Plant
(14) (360)
(15) Administration (361) (15H) Rehab (364) (17H) Dietetics Connecting Corridors (18H) Maintenance Shops Credit Union (19H) Medical Wards Mansion House (20H) Medical Media/IRMS Grist Mill
(20) Water Pumping Station REMRO
(22) Filter Plant (22H) Substance Abuse/Detox (23H) Geropsych Nursing
VHAPERGrayW Highlight
General Summary
AMA randomly tested surfaces for lead containing materials (LCM) throughout each above listed building at the Perry Point VAMC Campus.
Lead Inspector(s) – Andrew Washington (Maryland Risk Assessor 10057) Adam Truax (Maryland Lead Inspector 14117) Robert Schoennagel (Maryland Lead Inspector 4179) Kinte Thompson (Maryland Lead Inspector 13795) Patrick Dincher (Maryland Lead Inspector 7164) Ronald Stallard (Maryland Lead Inspector 4357)
The LCM testing was performed with a Radiation Monitoring Device (RMD) LPA-1 model x-ray fluorescence analyzer (XRF), Serial #1954. The XRF contains a small radioactive source (Cobalt 57), which emits radiation when pressed against a surface. If the paint contains lead, the radiation will stimulate the lead atoms to re-emit x-rays, which are sensed by a detector in the unit. The XRF then converts these signals to a final reading in milligrams of lead per square centimeter of surface area tested (mg/cm2). The LPA-1 XRF is capable of achieving a ninety-five percent confidence interval in readings to a depth of 3/8 inch.
The XRF was calibrated in accordance with the manufacturer's instructions. Prior to obtaining readings from suspect surfaces, three calibration readings were taken on a National Institute for Science and Technology (NIST) Calibration Test Block and recorded. The NIST Calibration Block contains a known concentration of lead (1.02 mg/cm2) and the XRF must indicate 1.02 mg/cm2 with a tolerance of + or - 0.3 mg/cm2 for the average of the three readings. If the average of three readings is within the established tolerance, the unit is working properly. Calibration checks were performed prior to and at the end of the investigation.
The LPA-1 XRF features two modes of operation when in use: Quick mode and Standard mode. When the Quick mode is engaged on the LPA-1, the unit seeks the shortest period of time to assure a positive, or a negative measurement with 95% confidence. As stated in the XRF Performance Characteristics Sheet (PCS) developed jointly by the U.S. EPA and the U.S. Department of Housing and Urban Development (HUD); no substrate correction is needed. The Quick mode was used during the course of the investigation.
Many types of components tested were found to contain greater than (>) 0.7 mg/cm2 of surface area tested, which is the amount defined as a lead-containing material according to the COMAR, Title 26, Department of the Environment, Subtitle 16, Lead, Chapter 01. Table I at the end of the report lists components that were found to have lead concentrations of >0.7 mg/cm2 within each building.
Table II lists all XRF readings that were found to be LCM.
There is no requirement to remove LCM prior to demolition activities for this type of building in the State of Maryland, only that components finished with LCM be tested, to determine the disposal requirements, following the requirements of the Resource Conservation and Recovery Act (RCRA) and any other applicable federal, state and local laws and regulations. In addition, contractors need to be made aware of the existence of LCM so their workers and the environment can be adequately protected. All lead-containing waste is to be handled and disposed of as hazardous waste unless toxic characteristic leaching procedure (TCLP) testing is performed and indicates otherwise. The waste shall be considered as hazardous when the concentration of lead exceeds 5 parts per million (ppm) by the TCLP.
The Occupational Safety and Health Administration (OSHA) Lead in Construction Standard (29 CFR 1926.62, with Maryland Amendments) must be adhered to during demolition to the LCM finished surfaces. This standard established the permissible exposure level (PEL) for lead at 50 micrograms per cubic meter (ug/m3) as an eight-hour time weighted average (TWA); the action level has been established at 30 ug/m3 as an eight hour TWA. This regulation also requires employers to use engineering controls and special work practices to reduce worker lead exposure to, at, or below the PEL. It also triggers several requirements regarding exposure monitoring, biological monitoring, and employee training when a worker is exposed to airborne lead levels at or above the action level.
Some painted surfaces may contain levels of lead at or below 0.7 mg/cm2, which are able to create lead dust or lead-contaminated soil hazards if the paint is turned into dust by abrasion, scraping, or sanding. Whenever renovation or demolition is performed on any painted components, an attempt should be made to control dust. If any surfaces with measurable amounts of lead are to be disturbed, it must be done so in accordance with the OSHA, and by trained personnel using appropriate techniques and respiratory protection. The OSHA does not honor threshold levels of lead in paint.
Below is the facility-wide damaged LCM assessment. Materials that were identified as having peeling, flaking, or chipping lead containing paint are listed. Some of the paint is deteriorated over large areas and these materials are listed as significantly damaged.
Facility Condition Summary for Lead Containing Material
(1H) Domiciliary
Significantly damaged lead paint in building includes: Plaster Ceilings
(2H) Domiciliary
Significantly damaged lead paint in building includes: Plaster Ceilings Isolated damaged lead paint in building includes: Plaster Walls
(3H) Administration
Significantly damaged lead paint in building includes: Plaster Ceilings, Wood Overhangs Isolated damaged lead paint in building includes: Plaster Walls, Metal Grates, Wood Door Jambs, & Wood Door Casings
(4) Research
No damaged lead paint identified
(4H) IRMS
Significantly damaged lead paint in building includes: Plaster Ceilings Isolated damaged lead paint in building includes: Metal Radiator Pipe, & Metal Fire Alarm Case
(5H) Director’s Office
Isolated damaged lead paint in building includes: Plaster Ceilings
(5) Stock Storage
Isolated damaged lead paint in building includes: Metal Stairwell, Concrete Floor, & Brick Window Sills
(6H) Voluntary Service
No damaged paint identified
(8) Engineering Storage
Isolated damaged lead paint in building includes: Metal Door Casings, Wood Door Casings, Metal Steps, & Metal Window Sash
(9H)
Significantly damaged lead paint in building includes: Concrete Walls Isolated damaged lead paint in building includes: Wood Door Frame, Metal Door Casings, Metal Pipe, Metal Window Sash, & Plaster Columns
(11) Warehouse
Significantly damaged lead paint in building includes: Metal Window Sash Isolated damaged lead paint in building includes: Brick Walls, Metal Door Casings, Metal I-beam, Metal Pipe, & Metal Cage
(11H) Human Resources
Isolated damaged lead paint in building includes: Plaster Ceilings
(13) Public Health Service
Isolated damaged lead paint in building includes: Terracotta Brick Ceilings
(13H) Psychiatric Units
Isolated damaged lead paint in building includes: Plaster Columns, Walls & Ceilings, Metal Sinks, Metal Door Casings, Ceramic Baseboard, Concrete Ceilings, Wood Door Train, Metal Hand rail, Concrete Door Trim Base, & Wood Door Trim Base
(14)
Isolated damaged lead paint in building includes: Terracotta Floors, & Metal Window Sash.
(14H) Psychiatric Units
Significantly damaged lead paint in building includes: Plaster Ceilings & Walls Isolated damaged lead paint in building includes: Metal Hand rail, Wood Window Casings, & Metal Grate
(15) Administration
Isolated damaged lead paint in building includes: Wood Window Sash, Metal Window Sash, Steel I-beam, Metal Structural Beam, Wood Door, Wood Door Frame, & Wood Window Frame
(15H) Rehab
No damaged paint identified
(17H) Dietetics
Isolated damaged lead paint in building includes: Metal Step, Metal Riser, Metal Hand rail, Concrete Ceiling, Metal Newel Post, & Metal Safety Rail
(18H) Maintenance Shops
Isolated damaged lead paint in building includes: Plaster Walls, Metal Fire Extinguisher Case, Metal Fan Casing, Metal Fire Protection Pipe, & Porcelain Sink
(19H) Medical Wards
No damaged paint identified
(20H) Medical Media/IRMS
No damaged paint identified
(20) Water Pumping Station
Isolated damaged lead paint in building includes: Wood Door Casings, & Concrete Base
(22) Filter Plant
Isolated damaged lead paint in building includes: Wood Column, Wood Stairs, & Wood Walls.
(22H) Substance Abuse/Detox
Isolated damaged lead paint in building includes: Porcelain Toilet, Porcelain Sink, Concrete Floor, & Metal Pipe
(23H) Geropsych Nursing
No damaged paint identified
(24H) Mental Health
Isolated damaged lead paint in building includes: Metal Hand rail
(25H) Mental Health
No damaged paint identified
(26) Fire House
(27H) Biomedical Shop
No damaged paint identified
(41) Greenhouse
Isolated damaged lead paint in building includes: Terracotta Walls, & Wood Soffit
(59)
No damaged paint identified.
(80H) Mental Health Clinic
Isolated damaged lead paint in building includes: Concrete Walls, CMU Wall, Wood Door, Wood Door Casings, Concrete Ceiling, Wood Soffit, & Wood Fascia
(82) Education/Research
Significantly damaged lead paint in building includes: Concrete Walls & Ceilings Isolated damaged lead paint in building includes: Wood Hatch Door, Wood Door Casings, Metal Pipe, Metal Door, Metal Door Casings, Wood Window Sash, Wood Window Casings, & Wood Window Sill
(97) Gatehouse
No damaged paint identified.
(101) Administration
Significantly damaged lead paint in building includes: Attic Steel Structure, Wood Structure Isolated damaged lead paint in building includes: Concrete Column, Steel I-beam, Steel Plank, Steel Joist, & Brick Walls
(102) Filter Plant
Isolated damaged lead paint in building includes: Wood Door, Walls, & Door Casings, & Metal Pipe.
(314A) Theater
Isolated damaged lead paint in building includes: Metal Window Lintel
(314B) Recreation
Isolated damaged lead paint in building includes: Metal Baseboard
(314C) Chapel
No damaged paint identified.
(315) Boiler Plant
Isolated damaged lead paint in building includes: Metal Tank
(321) Chiller Plant
Isolated damaged lead paint in building includes: Metal Support Column
(360)
Isolated damaged lead paint in building includes: Metal Corners
(361)
Isolated damaged lead paint in building includes: Metal Hand Rail
(364)
No damaged paint identified
Connecting Corridors
No damaged paint identified
Credit Union
No damaged paint identified
Mansion House
Significantly damaged lead paint in building includes: Plaster Walls and Ceilings, Wood Window Sill, Wood Shutter, Wood Door & Walls, Wood Awning, & Wood Window Casings Isolated damaged lead paint in building includes: Wood Stair Carriage, Wood Window Sash, Wood Door Casings, Wood Crown Molding
Grist Mill
Significantly damaged lead paint in building includes: Wood Door, Door Casings, & Window Casings
REMRO
If you have any questions regarding this summary or the attached data spreadsheets, please contact me at our office.
Sincerely, Andrew Washington Project Manager
Attachments
TABLE I – LEAD BASED PAINT COMPONENT TABLE
TABLE I
LBP COMPONENT TABLE
VA PERRY POINT
NOVEMBER 2013
Drywall Walls Terracotta Wall Wood Soffit
Building 59
No LBP
Building 80H
Concrete Walls Plaster Walls, Columns, & Ceilings Wood Crown
Molding Wood
Window Sill Wood Window
Casing Metal
Radiator Metal Door
Casing
Wood Shelf Ceramic Glazed Tile Wood Door
Casings Plaster Door
Casing Metal Newel Post
Metal Sprinkler
CMU Wall
Concrete Ceiling Wood Door Wood Window Concrete Column
Wood Column Wood Soffit Wood Fascia
Building 82
Plaster Walls, Ceilings, & Columns
Wood Crown Molding Wood Window
Casing Wood
Window Sill Wood Fireplace
Mantle Wood Door
Wood Door Casing
Metal Door Casing Metal Door Jamb Plaster Door
Casing Porcelain
Sinks Metal Ladder
Metal Roof Hatch
Wood Shelf
Metal Radiator Concrete Walls Concrete Ceiling Wood Hatch
Door Metal Pipe Metal Door Wood Column
Wood Fascia Wood Soffit Wood Decorative
Trim Wood
Window Sash
Building 97
Wood Window Sash Plaster Walls &
Ceiling Wood Door
Wood Door Casings
Wood Window Sill
Wood Window Casing
Wood AC Casing
Wood Soffit Wood Fascial Board
Building 101
Stucco Walls Concrete Columns Metal Door
Casings Metal Bottom
Trim Steel Structure
Wood Structure
Steel I-beam
Steel Plank Steel Joist Brick Walls Concrete
Down Spout Building 102
Wood Door Wood Door Casing Wood Wall Metal Pipe
Building 314A
Metal I-beam Metal Door Lintel Ceramic Wall Metal Hand rail Metal Newel Post
Metal Stair Stringer
Metal Kick Plate Riser
Metal Stairtread Metal Window Lintel Metal Base Plate
Building 314B
Metal Baseboard Metal Hand rail Wood Alley Floor
Strip Metal Newel
Post Metal Stair
Stringer Metal Stair
Riser Metal Stair Carriage
Metal I-beam
Building 314C
Metal Window Lintel
Building 315
Metal Wall Metal I-beam Metal Pipe Metal Boiler Metal Tank Metal Trench
Cover Metal Door
TBL I-4
TABLE I
LBP COMPONENT TABLE
VA PERRY POINT
NOVEMBER 2013
Building 321
Metal Door Casing Metal I-beam Metal Pipe Metal Tension
Rods Metal Support
Column
Building 360
Ceramic tile Metal Stall Metal Corner Metal Ladder Metal Pipe Metal Loading
Plate
Building 361
Ceramic tile Wall Metal Hand rail
Building 364
No LBP Connecting Corridors
Metal Ballard Metal Corner
Protector Metal Door
Metal Door Casing
Metal Door Lintel Metal Window
Lintel
Credit Union
No LBP
Mansion House
Plaster Walls & Ceilings
Wood Crown Molding Wood
Baseboard Wood Door
Wood Window Panel
Wood Fire Mantle
Wood Fireplace Case
Wood Window Sill Wood Window
Casing Wood Window
Well Wood Door
Casings Wood Shelf
Wood Window Sash
Wood Stair Carriage
Ceramic tile Wall Wood Shutter Concrete Walls Wood Walls Wood Awning
Grist Mill
Wood Door Wood Door Casing Wood Window
Casing
REMRO
Porcelain Sink
TBL I-5
TABLE II – POSTIVE XRF TABLE
TABLE II
POSITIVE XRF TABLE
VA PERRY POINT
NOVEMBER 2013
Sample # Location Color Component Substrate Condition Result
(mg/cm2)
127 Exterior - south wall Red I-beam Metal Intact 4.3 128 Exterior -south wall Red I-beam Metal Intact 8.2
Building 314C
057 Vestry room Green Window lintel Metal Intact 5.9 Building 315
004 Main room Gray Wall Metal Intact 0.8 005 Main room Tan I-beam Metal Intact 0.8 007 Main room Green Pipe Metal Intact 0.8 011 Main room Black Boiler Metal Intact 3.9 013 Main room Green Pipe Metal Intact 0.8 018 Main room Off-white Tank Metal Not intact 0.8 022 Main room Gray Trench cover Metal Intact 0.8 024 Main room Orange Door Metal Intact 3.0 039 Bathroom White Door Metal Intact 3.8 047 Exterior Black Wall Metal Intact 0.8
Building 321
005 Office Off-white Door casing Metal Intact 2.0 008 Office White I-beam Metal Intact 4.4 017 Boiler room Yellow I-beam Metal Intact >9.9 024 Main boiler room Yellow I-beam Metal Intact 3.0 026 Main boiler room White Pipe Metal Intact 0.8 030 Main boiler room Yellow Tension rods Metal Intact 3.4
042 Exterior Tan Support column Metal Not intact 3.5
Building 360
015 Men's room 102 Red Tile Ceramic Intact 9.3 016 Men's room 102 Orange Stall Metal Intact 0.8 034 Storage Tan Corner Metal Not intact 2.1 035 Storage Gray Ladder Metal Intact 0.8 044 Storage area Tan Corner Metal Not intact 1.6 119 2nd floor NEMER Off-white Pipe Metal Intact 0.8 180 Exterior Black Loading plate Metal Intact 2.5
Building 361
Ground floor - men's bathroom Green Wall Ceramic tile Intact >9.9
Ground floor - men's bathroom Blue Wall Ceramic tile Intact >9.9 068 Ground floor - stair #1 Red Handrail Metal Intact 0.8 182 Exterior - south wall Tan Handrail Metal Not intact 0.8
Building 364
No Positives onnecting Corridors
029 14H -15H Corridor Yellow Ballard Metal Intact 0.8
TBL II-24
VHAPERGrayW Highlight
XRF FIELD SHEETS
Building 315 Lead Documentation
Building 321 Lead Documentation