Life Safety Drawings Building 1 and CA.pdf
PDF 5 MB Posted
- Attached to
- Z1DA--Replace Dialysis Sanitary Lines Federal contract opportunity
- Solicitation number
- 36C24525B0002
About this file
This is a set of life safety plan drawings for Buildings 1 and 2 at the Louis A. Johnson VA Medical Center in Clarksburg, WV. The drawings detail fire safety and emergency egress features across multiple floors, including the basement through 6th floor and penthouses.
The plans show detailed layouts with fire barriers, smoke barriers, smoke partitions, exits, hazardous areas, sleeping and non-sleeping suites, horizontal exits, and locations of fire alarm control panels and fire pumps. The drawings include specific zone designations and square footage calculations for different areas, along with detailed legends explaining wall requirements, opening protections, and code references from the 2012 Life Safety Code. Key features shown include 1-hour, 2-hour, and 3-hour fire barriers, smoke resistant corridor walls, and suite separations with associated requirements for doors, glazing, smoke dampers, and penetrations. The drawings were prepared by ART Architecture Engineering in Vienna, VA and dated February 28, 2020.
View the file
Other files for this federal contract opportunity
Show all 32
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
B
I
D
S
E
T
Project Number Office of
Construction and Facilities Management
Building Number
Revisions Date
Drawing Number
CONSULTANTS: ARCHITECTS/ENGINEERS: VA CLARKSBURG
987654321
987654321
Project Title
Location
Date Checked Drawn
Drawing Title
Approved: Project Director
KEY PLAN 540-20-110
02/28/2020
1 Medical Center Drive, Clarksburg, WV 26301
FINAL 02/28/2020
SEAL
RSM JLO
LS-00.0
LIFE SAFETY PLAN
COVER SHEET
ART - ARCHITECTURE - ENGINEERING
2787 Hill Road Vienna, VA 22181
Phone: (703) 938-5226
Contact: Frank Sturgeon AIA, NCARB
A DESIGN GROUP, LLC
LEGEND
BUILDING SEPARATION
HORIZONTAL EXIT
3-HOUR FIRE BARRIER
2-HOUR FIRE BARRIER
1-HOUR FIRE BARRIER
30 MINUTE FIRE BARRIER
SMOKE BARRIER
SMOKE PARTITION
SMOKE RESISTIVE CORRIDOR WALL
EXIT
NON-PATIENT CARE OCCUPANCIES
HAZARDOUS AREA
NON-SLEEPING SUITE
NON-PATIENT SUITE
HORIZONTAL BARRIER TRANSFER
FIRE ALARM CONTROL PANEL
FIRE PUMP
TRASH CHUTE
SLEEPING SUITE
NON-SPRINKLER PROTECTED AREA
FP
LINEN CHUTE
TC
LC
FACP
Life Safety Information Per Line Type
Line Designation Wall Requirements Opening Protection Requirements
Additional Information Code References
Smoke Barrier
◊ Same construction as a 1-hour fire barrier: one layer of 5/8-inch gypsum on each side of studs.
◊ 1/3-hour fire/smoke rated door.
◊ Fire rated glazing size is limited to maximum area tested.
8.5
◊ Existing health care occupancies designed prior to the 1970s the barrier may be constructed as a 30-minute fire barrier.
◊ Wired glazing or 1/3-hour fire rated glazing (D-H-20).
◊ Smoke dampers are required in transfer openings within smoke barriers.
◊ All penetrations must be sealed with an approved fire stop assembly or existing fire stop in good condition. Painted fire stop is not permitted.
◊ Doors must be self-closing.
◊ Smoke dampers are required by most Building Codes.
◊ Positive latching hardware is not required but if it is provided it must work properly.
◊ The slabs between floors are also classified as smoke barriers. Smoke dampers ARE required in all ducts penetrating the slab (8.6.1).
◊ All door hardware must be UL listed for use on fire rated doors.
◊ Clearance under the door can be no larger than ¾-inch.
◊ Gaps around the door must be as tight fighting as possible (generally 1/8-inch is accepted).
◊ Smoke dampers are NOT required by The Life Safety Code in smoke compartments with fully ducted HVAC systems and complete sprinkler protection.
Smoke Partition (Sprinkler Protected
Hazardous Area Protection)
◊ There is no hourly rating noted in Section 8.4, however, Table 8.3.4.2 of the 2012 Edition notes a 30-minute fire rating.
◊ Doors must meet the requirements of 7.1
◊ Most Building Codes require corridor walls in health care occupancies to be smoke partitions and extend to the underside of the slab above.
8.4, 18/19.3.2
◊ Walls can terminate at smoke resistive ceiling provided the ceiling is smoke tight, the area above the ceiling is not a plenum, and there is a smoke tight joint between the wall and the ceiling.
◊ Clearance under the door can be no larger than ¾-inch.
◊ All penetrations must be protected with a material capable of limiting the transfer of smoke.
◊ Gaps around the door must be as tight fighting as possible (generally 1/8-inch is accepted).
◊ Doors must be self-closing.
◊ Smoke dampers are required to protect any air-transfer openings.
Smoke Resistive Corridor Wall
◊ Existing corridor walls in smoke compartments without complete sprinkler protection are required to be 30-minute fire resistance rated.
◊ Doors must be constructed to limit the transfer of smoke.
◊ Only found in health care occupancies.
18/19.3.6
◊ In fully sprinkler protected smoke compartments walls can terminate at the smoke resistive ceiling, provided the ceiling limits the transfer of smoke.
◊ Clearance under the bottom of the door can be no larger than 1-inch.
◊ Most Building Codes require corridor walls in health care occupancies to be smoke partitions and extend to the underside of the slab above.◊ No fire resistance rating of the wall is required in fully sprinkler protected smoke compartments.
◊ Doors must positive-latch.
◊ Wall shall form a barrier to limit the transfer of smoke.
◊ Roller latches are prohibited per CMS requirements.
◊ Restrooms and shower rooms are exempt from the protection requirements.
◊ Louvers are prohibited.
◊ Restrooms and shower rooms are exempt from protection requirements.
◊ Power operated doors are exempt from latching requirements provided the power device is capable of keeping the door closed with a 5-lb force applied to the latch side of the door and is acceptable to the AHJ.
See Corridor Wall Line Types Suite Separations
◊ Walls separating suites are the same as the corridor walls within the smoke compartment.
◊ See requirements in corresponding corridor wall type.
◊ Suite separations are provided around the entire perimeter of the suite, except at fire rated barriers or exterior walls.
18/19.2.5.7
◊ See requirements in corresponding corridor wall type.
Code references are from the 2012 Edition of the Life Safety Code®
Life Safety Information Per Line Type
Line Designation Wall Requirements Opening Protection Requirements
Additional Information Code References
Building Separation
◊ Also known as fire walls.
◊ No utilities are to pass through the fire walls.
◊ Not common in health care facilities unless there are differing construction types. 8.2.1, NFPA 220◊ Walls are structurally independent.
◊ Opening protection fire resistance rating based on the rating of the fire wall.◊ Wall must stack vertically.
Based on Rating - See Types Below Occupancy
Separations
◊ See the wall requirements for the corresponding fire barrier noted below.
◊ See the opening protection requirements for the corresponding fire barrier noted below.
◊ Hourly rating determined by the occupancy types being separated. See Table 6.1.14.4.1.
6.1.14.4.2
Horizontal Exit
◊ See requirements for 2-hour fire barrier below.
◊ See requirements for 2-hour fire barrier below.
◊ Fire rated glazing size is limited to max area tested.
7.2.4, 7.2.4.3.1, 7.2.4.4, 8.3
◊ Barrier must stack vertically from grade level to highest floor required.
◊ Opening protection in 10 ft exposure protection at exterior walls required to be ¾-hour
◊ The Building Code may have additional requirements.
◊ If barrier terminates at exterior wall with less than 180-degree angle, 10 feet on either side of the barrier must be protected with 1-hour fire rating.
◊ Doors must be opposite swinging when located across a corridor or swing in the direction of egress when in a wall.
◊ Side lights, transoms, and windows in walls limited to fire resistance rated glazing (D-H-W-120).
◊ Horizontal exits may also require a fire alarm manual pull station on each side of the doors and a fire hose connection (standpipe) on each side of the doors.
3-hour Fire Barrier
◊ Masonry or three layers of 5/8-inch gypsum on each side of studs.
◊ 3-hour fire rated door.
◊ Fire rated glazing size is limited to 100
sq. in.
8.3
◊ All penetrations must be sealed with an approved fire stop assembly or existing fire stop in good condition. Painted fire stop is not permitted.
◊ Wired glazing or 3-hour fire rated glazing (D-H-180).
◊ These barriers are mostly used for separation of construction types.
◊ Door must be self-closing and positive latching.
◊ Side lights, transoms, and windows in walls limited to fire resistance rated glazing (D-H-W-180).
◊ All door hardware must be UL listed for use on fire rated doors.
◊ Clearance under the door can be no larger than ¾-inch.
◊ Gaps around the door must be as tight fighting as possible (generally 1/8-inch is accepted).
◊ Fire dampers required.
2-hour Fire Barrier
◊ Masonry or two layers of 5/8-inch gypsum on each side of studs.
◊ 1.5-hour fire rated door.
◊ Fire rated glazing size is limited to maximum area tested.
8.3
◊ All penetrations must be sealed with an approved fire stop assembly or existing fire stop in good condition. Painted fire stop is not permitted.
◊ Wired glazing or 1.5-hour fire rated glazing (D-H-90).
◊ Side lights, transoms, and windows in walls limited to fire resistance rated glazing (D-H-W-120).
◊ Door must be self-closing and positive latching.
◊ These barriers are used for separation of construction, shaft enclosures, horizontal exits and occupancy separations.
◊ All door hardware must be UL listed for use on fire rated doors.
◊ Clearance under the door can be no larger than ¾-inch.
◊ Gaps around the door must be as tight fighting as possible (generally 1/8-inch is accepted).
◊ Fire dampers required.
1-hour Fire Barrier
◊ One layer of 5/8-inch gypsum on each side of studs.
◊ 3/4-hour fire rated door.
◊ Fire rated glazing size is limited to maximum area tested.
8.3
◊ All penetrations must be sealed with an approved fire stop assembly or existing fire stop in good condition. Painted fire stop is not permitted.
◊ Wired glazing or 3/4-hour fire rated glazing (D-H-45).
◊ These barriers are used as occupancy separations, some shaft enclosures, and hazardous area protection as well as some special protection for specific situations (electrical, generators, medical gas).
◊ Door must be self-closing and positive latching.
◊ Some Building Codes require 1-hour corridor walls in non-sprinkler protected business occupancies.
◊ All door hardware must be UL listed for use on fire rated doors.
◊ Clearance under the door can be no larger than ¾-inch.
◊ Gaps around the door must be as tight fighting as possible (generally 1/8-inch is accepted).
◊ Fire dampers required when complete sprinkler protection is not provided.
30-minute Fire Barrier
◊ One layer of 5/8-inch gypsum on one side of studs or one layer of standard gypsum on both sides of studs.
◊ 1/3-hour fire rated door.
◊ Fire rated glazing size is limited to maximum area tested.
8.3
◊ All penetrations must be sealed with an approved fire stop assembly or existing fire stop in good condition. Painted fire stop is not permitted.
◊ Wired glazing or 1/3-hour fire rated glazing (D-H-20).
◊ In health care occupancies we only see 30-minute fire barriers used to protect corridor walls in smoke compartments without complete sprinkler protection.
◊ Self-closing doors not required in health care occupancies.
◊ All door hardware must be UL listed for use on fire rated doors.
◊ Clearance under the door can be no larger than ¾-inch.
◊ Gaps around the door must be as tight fighting as possible (generally 1/8-inch is accepted).
◊ Fire dampers are NOT required.
Tel: 703-717-5628
VIENNA, VA 22182
SUITE 355
8230 BOONE BLVD
CAPITOL FPE, LLC
CAPITOL FPE, LLC
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text one and one-half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text three-quarters inch = one foot
AutoCAD SHX Text one-half inch = one foot
AutoCAD SHX Text three-eighths inch = one foot
AutoCAD SHX Text one-quarter inch = one foot
AutoCAD SHX Text one-eighth inch = one foot
AutoCAD SHX Text 0 4 8 16
AutoCAD SHX Text 0 4 8
AutoCAD SHX Text 0 4
AutoCAD SHX Text 0 4
AutoCAD SHX Text 6" 0 2
AutoCAD SHX Text 6" 0 2
AutoCAD SHX Text 6" 0 1
AutoCAD SHX Text 6"
COOLER
DRAIN
WELL
REMOVED
#18 s s
S
S
S
S
S
S
B 117B
B 117A
B 113
B122B 112
B 120
1B 101 B 110 1B 109
1B 100 B102
1B 106
122A
122B
B123A
B 122C 39A
B 122 K34
B 122J
35A
B 122M
B119
B118
40A
45B
B 130B
46C
B141
B 161 B 163
B 145 B 126
B 128 B 138
61A
82A
RAMP
DOCK
DOCK
B 111A
B 111
B 117
DOCK
4A
15A
CO1
10B CO2
B123C
4E
B 123
4C
CO4
B 130E
45D
STAIR `A'
HSKP
1B 103
SOILED
F.CCO
B 104
MECH
B 117
SERVER ROOM
B 108
B 122L
COOLER
B 130D
B 130C
F.CCO
B 122D
B 139
STAIR C
B 137
B 130G
B 130F
B 130A
B 131
OFFICE
B 122N
B 160
B 147
B 149
B 150
MECH
PRIVACY
OFFICE
B 144B 142
OFFICE
B 146
STORE
B 151
B 165OFFICE
B 155
OFFICE
B 162
LOCKER ROOM
B 166
B 164
OFFICE
B 154
B 140 B 143
LOCKER ROOM
B 156
STAIR-E
B 158
PI
PE
C
HA
SE
B
ST
AI
R-
B
B 105
MECH
B 125
MECH
B 130
ELEC
B 127
F.CCO
B159
STAIR D
B 153
B 128
B 122F
W.TLT.
B 129
ELEVATORELEVATOR ELEVATOR
B 125
B132
B 124 B 122C
COOLER
COOLER
FREEZER
FREEZER
FREEZER
BIOINFECTIOUS
WASTE STORAGE
STORAGE
HALLWAY
AUTOPSY RM
UTILITY
HALLWAY
HALLWAY
ALCOVE
STORAGE
SLIDE
FEC
CLOSET
JANITOR
MECH
P-2
P-1
S-1
B204
B202
BF 109
BF 110
B211
BF 108B
BF 108A
BF 116
BF 116A
OFF.
B231AOFF.
B231
OFF.
B232OFF.
B233
OFF
B234
B235A
B235
OFF.
B235C
OFF.
B235B
HSKP
B236MECH.
B241
MECH.
B242
OFF.
B239
B238B237
TEL.
B222
ELEC.
B223
STORE
B225
OFF.
B230
OFF.
B224
OFF.
B226
OFF.
B228
OFF.
B229
FILE RM.
B218B
OFF.
B218A
B218
STAIR-H
B220B
B220C
B220A
B220
B219F
HSKP
B219E
B219C
B219B
TEL
B209
ELEC
B208
B207MECH
B206
B204B
ELEC
B205
B204A STAIR-C
B210
ELEC. RM.
BF 103
STOR
B201
B200
B219A
F.LOCKER
B213
M.LOCKER
B212
OFF.
B240
B219C
B 217
B219
B230
B221
BF 111E
B215B
MEDICAL
B214A
PHAR.
ADMIN.
B214
B215
HSKP
B216
B215A
PREPARATIONS
BREAKOUT
RECORDS
FILE RM
GENERATOR
TO NURSING
HOME
PROSTHETICS
STORAGE
CONFERENCE ROOM
B234A
OFFICE
OFFICE
CART
WASHER
ELECTRICAL
RECEIVING
CHASE
MED GAS
B227A B227B
STAIR-B
STAIR A
L C
L C
STAIR B
STAIR C
STAIR D
STAIR E
STAIR G
STAIR H
STAIR F
AREA UNDER RENOVATION
AT TIME OF SURVEY
STAIR J
CURRENTLY
VACANT
AWAITING
RENOVATION
1-B-003
1-B-001, 1-B-002
1-B-004
1-B-005
1-B-006, 1-B-007
1-B-008
1-B-010
1-B-009
1-B-011
1-B-012
1-B-013
1-B-014
1-B-018
1-B-015, 1-B-016
1-B-017
1-B-019
1-B-020 1-B-021
1-B-022
1-B-023
1-B-024, 1-B-030
INCOMING H2O
1-B-025
1-B-026
1-B-027
1-B-028, 1-B-031
INCOMING H2O
INCOMING H2O
1-B-029
2-B-001
2-3-002
2-B-005
2-B-006, 2-B-007
2-B-008 2-B-009
2-B-010
2-B-003
2-B-011
2-B-012
2-B-013
2-B-014
2-B-015
TEMPORARY TRAILER
FACP
SCALE: 1/16" = 1'-0"
BLDG. 2 - BASEMENT
40430 SQ FT
ZONE 1-B-A
38570 SQ FT
ZONE 2-B-A
2-B-004
2-B-017
2-B-016
B
T
Project Number Office of
Construction and Facilities Management
Building Number
Revisions Date
Drawing Number
CONSULTANTS: ARCHITECTS/ENGINEERS:
1 & 2
VA CLARKSBURG
987654321
987654321
Project Title
Location
Date Checked Drawn
Drawing Title
Approved: Project Director
KEY PLAN
02/28/2020
1 Medical Center Drive, Clarksburg, WV 26301
SEAL
LS-1 2.B
LIFE SAFETY PLAN
BUILDING 1 & 2
BASEMENTART - ARCHITECTURE - ENGINEERING
2787 Hill Road Vienna, VA 22181
Phone: (703) 938-5226
Contact: Frank Sturgeon AIA, NCARB
A DESIGN GROUP, LLC
LEGEND
BUILDING SEPARATION
HORIZONTAL EXIT
3-HOUR FIRE BARRIER
2-HOUR FIRE BARRIER
1-HOUR FIRE BARRIER
30 MINUTE FIRE BARRIER
SMOKE BARRIER
SMOKE PARTITION
SMOKE RESISTIVE CORRIDOR WALL
EXIT
NON-PATIENT CARE OCCUPANCIES
HAZARDOUS AREA
NON-SLEEPING SUITE
NON-PATIENT SUITE
HORIZONTAL BARRIER TRANSFER
FIRE ALARM CONTROL PANEL
FIRE PUMP
TRASH CHUTE
SLEEPING SUITE
NON-SPRINKLER PROTECTED AREA
FP
LINEN CHUTE
TC
LC
FACP
SCALE: 1/16" = 1'-0"
BLDG 1 - BASEMENT
540-20-110
FINAL 02/28/2020 RSM JLOTel: 703-717-5628
VIENNA, VA 22182
SUITE 355
8230 BOONE BLVD
CAPITOL FPE, LLC
CAPITOL FPE, LLC
AutoCAD SHX Text
O.H.DOOR
AutoCAD SHX Text
ELECTRICAL ROOM
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
O.H.DOOR
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text one and one-half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text three-quarters inch = one foot
AutoCAD SHX Text one-half inch = one foot
AutoCAD SHX Text three-eighths inch = one foot
AutoCAD SHX Text one-quarter inch = one foot
AutoCAD SHX Text one-eighth inch = one foot
AutoCAD SHX Text 0 4 8 16
AutoCAD SHX Text 0 4 8
AutoCAD SHX Text 0 4
AutoCAD SHX Text 0 4
AutoCAD SHX Text 6" 0 2
AutoCAD SHX Text 6" 0 2
AutoCAD SHX Text 6" 0 1
OFFICE
1109F
TOILET
1109G
STOR.
1109H
EXAM
1109I
BIOPSY/ULTRAS
132B
MAMMO
1109E
EXAM
1109J
EXAM
1109K
SPRIN.
1109D
CORR
138B
EXAM
1109L
SOILED
1109B
RECEPT.
1109M
OFFICE
1109N
PATIENT
1109A
SYSTEMS
1109B1
CORRIDOR
WAITING
EDUC.
EXAM ROOM
1124W
EXAM ROOM
1124V
EXAM ROOM
1124Q
EXAM ROOM
1124O
LASER ROOM
1124N
PHOTO ROOM
1124L
UTILITY
1124K
ROOM
1122C
WAITING AREA
1124H
ROOM
1124F
TREATMENT ROOM
1122D
ULTRASOUND ROOM
1124D
FITTING/DISPENSING
1124B
LOCKER ROOM
1124C
ROOM
1124E
RECEPTION
1124A
TOILET
BATH
DRESSING AREA
WORK AREA
CORRIDOR
CORRIDOR
STATIONS
113F
CORRIDOR
1124Z
ROOM
1124X
CORRIDOR
116Y
WORK AREA
1124U
PREP
1124R
TOILET
1124N
CORRIDOR
116N
CORRIDOR
116BB
CORRIDOR
116B
WAITING
WOMEN
MEN
CORRIDOR
CORRIDOR
WAITING AREA
1114A
CLOSET
CLEAN
CORRIDOR
113K
ROOM
1124G
PRETEST
PRETEST
EMPLOYEE
EXAM
ROOM
1124Y
EXAM
CONSULTATION/
MED
PATIENT
ROOM
1124T
EXAM
ROOM
1124S
EXAM
HOLDING
1124J
SOILED
TREATMENT
DILATION
VISUAL FIELDS
TREATMENT
HSKPG
CLERKS/
ADVOCATE
PATIENT
REPAIR
WHEEL CHAIR
STORAGE
WHEELCHAIR
PATIENT
HYDROTHERAPY
PIPE CHASE
WAITING
AREA
RECEPTION
CHECK-IN
1115A
CONSULTATION
ROOM
1115B
PHYSICIAN
OFFICE
1115C
EXAM
ROOM
1115D
EXAM
ROOM
1115E
CLEAN
UTILITY
1115F
CORRIDOR
PIPE CASE
ONCOLOGY
SOILED
UTILITY
1115G
TREATMENT
AREA
1115H
MED-PREP
ROOM
1115I
PATIENT
TOILET
1115J
PIPE CHASE
CORRIDOR
CORRIDOR
CHAPEL
CORRIDOR
116T
CORRIDOR
ADL
1122E
NURSE'S STATION
EXAM ROOM
EXAM ROOM
EXAM ROOM
EXAM ROOM
EX.
EXAM
EXAM
EXAM
1143A
SOILED LINEN
CLEAN
UTILITY
BREAK
ROOM
TLT
CLASS RM
OFF.
OFF.
OFF.
WAITING
PIPE CHASE
EX.
OFF.
TEL.
W.TLT
M.TLT
EX
TRIAGE
ROOM
TRIAGE
EX
LINEN
SOILED
EXAM
STAIR-D
F.CCO.
UTILITY CLO.
F.CCO.
STAIR-E
CORRIDOR
138A
GYM
STORAGE
1122A
ELEVATORELEVATOR ELEVATOR
STAIR
STAIR
STAIR
EX.
PRAYER ROOM
1125A
PIPE CHASE
1152A
1129B
1129A
1124I
CLOSET
1124AA
ELECTRICAL
1109C
STAIR
1125C
1125B
S-1
P-1
P-2
MECH.
SHAFT
EX
EX
EX
EX
EX
TLT
HSKP
STAIR-G
N.STATION
WORK RM
EX
EX
EX
EX
EX
EX
EX
N.STATION
CLEAN
EX
EX
W.TLT
N.CLINIC
M.TLT
UTILITY
OFF
BREAK ROOM
EX
EX
EX
MED.RM
EX
EX
EX
OFF
EX
ELEC
TEL
EX
1278A
TLT
1291B
1291A
EX
EX
1200C
1200B
OFF
RETAIL STORE
OFF
1200A
STOR
REFRIGERATOR
REF
KIT
HSKP
1210C
ELEC
TEL
STAIR-H
STOR
12251226
OFF
OFF
1232A
1232B
1232C
1232D
1232F
TLT
1232E
OFF
MRI
AMBULANCE
ENTRANCE
EXAM RM
ELECTRICAL
SHAFT
ELEV
LOBBY
1210C
M. TLT
VENDING
STORAGE
1210E
CAFE
STORAGE
1210A
CAFE
W. TLT
OFFICE
OFFICE
HSKP
CORRIDOR
1210B
ELECT
CLOSET
ELEC CLOSET
1210D
MECH
TRAINING
1102E
OFFICE
1102D
OFFICE
1102C
STORAGE
1102F
TOILET
1102B
RECEPTION
CORRIDOR
C-1101-1
BREAK
1102A
AREA
1100C
MULTIPURPOSE A
1100B
MULTIPURPOSE B
MULTIPURPOSE C
OFFICE
1101B
OFFICE
C-1100-1
CORRIDOR
VESTIBULE
105A
CORRIDOR
1100D
STORAGE
1100E
ELEC.
ROOM
SECURITY
C O
R R
I D
O R
1133A
1220G
1220F
1220E
1220D
BED 1
BED 2
BED 3
BED 4
BED 5
BED 6
BED 7
BED 8
1220C
1220I
1220J
1220N
1220K
1220M
1220H
OFFICE-CHIEF
PROSTHETICS
UP
STAIR 'J'
1249B
MECH.
EXAM
1249A
EXAM
1249C
EXAM
1249F
EXAM
1249E
EXAM
1249D
TOILET
1249G
EXAM
1249H
PHARM
1249I
EXAM
1249J
WORK
STATION
SOCIAL WORK
1257A
EXAM TOILET
EXAM
EXAM
VESTIBULE
1241A
ELECTRICAL
INFORMATION
LOBBY
1241B
HSKP
DN
Valet
CL-19
CL-11
EXAM
CLERKS
LC
LC
STAIR A
STAIR B
STAIR C
STAIR E
STAIR F
STAIR H
STAIR G
STAIR D
STAIR J
35489 SQ FT
ZONE 1-1-A
7383 SQ FT
ZONE 2-1-A
22425 SQ FT
ZONE 2-1-B
11065 SQ FT
ZONE 2-1-C
946 SQ FT
ZONE 2-1-D
SCALE: 1/16" = 1'-0"
BLDG 1 - FLOOR 1
SCALE: 1/16" = 1'-0"
BLDG 2 - FLOOR 1
TO STATE NURSING HOME
1-1-001 1-1-004
1-1-002
1-1-003 1-1-005
1-1-006
1-1-007
2-1-001
2-1-002
2-1-003 2-1-004
2-1-005
2-1-006
2-1-007
2-1-008
2-1-009, 2-1-010
2-1-011
2-1-012
2-1-013
2-1-014
B
T
Project Number Office of
Construction and Facilities Management
Building Number
Revisions Date
Drawing Number
CONSULTANTS: ARCHITECTS/ENGINEERS:
1 & 2
VA CLARKSBURG
987654321
987654321
Project Title
Location
Date Checked Drawn
Drawing Title
Approved: Project Director
KEY PLAN
02/28/2020
1 Medical Center Drive, Clarksburg, WV 26301
SEAL
LS-1 2.1
LIFE SAFETY PLAN
BUILDING 1 & 2
FLOOR 1ART - ARCHITECTURE - ENGINEERING
2787 Hill Road Vienna, VA 22181
Phone: (703) 938-5226
Contact: Frank Sturgeon AIA, NCARB
A DESIGN GROUP, LLC
LEGEND
BUILDING SEPARATION
HORIZONTAL EXIT
3-HOUR FIRE BARRIER
2-HOUR FIRE BARRIER
1-HOUR FIRE BARRIER
30 MINUTE FIRE BARRIER
SMOKE BARRIER
SMOKE PARTITION
SMOKE RESISTIVE CORRIDOR WALL
EXIT
NON-PATIENT CARE OCCUPANCIES
HAZARDOUS AREA
NON-SLEEPING SUITE
NON-PATIENT SUITE
HORIZONTAL BARRIER TRANSFER
FIRE ALARM CONTROL PANEL
FIRE PUMP
TRASH CHUTE
SLEEPING SUITE
NON-SPRINKLER PROTECTED AREA
FP
LINEN CHUTE
TC
LC
FACP
Tel: 703-717-5628
VIENNA, VA 22182
SUITE 355
8230 BOONE BLVD
CAPITOL FPE, LLC
CAPITOL FPE, LLC
540-20-110
FINAL 02/28/2020 RSM JLOTel: 703-717-5628
VIENNA, VA 22182
SUITE 355
8230 BOONE BLVD
CAPITOL FPE, LLC
CAPITOL FPE, LLC
AutoCAD SHX Text
CURTAINS
AutoCAD SHX Text
CURTAINS
AutoCAD SHX Text
SLDR
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
COMPUTER
AutoCAD SHX Text
WORKSTATION
AutoCAD SHX Text
%%UEYE CLINIC
AutoCAD SHX Text
%%UPT
AutoCAD SHX Text
RAMP DN
AutoCAD SHX Text
RAMP DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
NORTH ELEVATORS
AutoCAD SHX Text
AC
AutoCAD SHX Text
PB
AutoCAD SHX Text
AC
AutoCAD SHX Text
AC
AutoCAD SHX Text
AC
AutoCAD SHX Text
PB
AutoCAD SHX Text
PB
AutoCAD SHX Text
FOYER
AutoCAD SHX Text
AutoCAD SHX Text
CONTROL RM
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EQUIP'T RM
AutoCAD SHX Text
AutoCAD SHX Text
HC BATHRM
AutoCAD SHX Text
AutoCAD SHX Text
IV START RM
AutoCAD SHX Text
AutoCAD SHX Text 1100A
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text one and one-half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text three-quarters inch = one foot
AutoCAD SHX Text one-half inch = one foot
AutoCAD SHX Text three-eighths inch = one foot
AutoCAD SHX Text one-quarter inch = one foot
AutoCAD SHX Text one-eighth inch = one foot
AutoCAD SHX Text 0 4 8 16
AutoCAD SHX Text 0 4 8
AutoCAD SHX Text 0 4
AutoCAD SHX Text 0 4
AutoCAD SHX Text 6" 0 2
AutoCAD SHX Text 6" 0 2
AutoCAD SHX Text 6" 0 1
2101G
2101E
2101B
2101A
2111A
2100A
2126 2127
2131B
2141 2142
2180 2181
RR
STAIR E
2131A
2147D
2133A
2106B 2106C 2106D
2106E
2106A
OFF
OP-4 OP-3 OP-2 OPERATORY-1
STOR
STOR
STAIR-B
DENTAL LAB
EDUCATION RM.
F.CLO
2101D
EX
RECEPTION
EX
WORK ROOM
LIBRARY
STAIR-A
2124B
TOILET
P I P
E
C
H A
S E
OFFICE
STOR
OFFICE OFFICE
OFFICE
2145A
JANITOR
EXAM ROOM
OFFICE
OFFICE
OFFICE OFFICE
TEL.
LOBBY
WAITING
STOR
EKG LAB
OFFICE
ECHO LAB
OFFICE
OXYGEN
OFFICE
STOR
WAITING
TEST BOOTH
STOR
MECH
F.CCO
TEL.CLO.
OFFICE
CONFERENCE
HSKP
F.CCO
OFFICE
TRAINING ROOM-B
TRAINING ROOM-A
CONFERENCE ROOM
OFFICE
OFFICE
OFFICE
ELEVATORELEVATOR ELEVATOR
STOR
MECH
F.CCO
F.CCO
STAIR-C
OFFICE
STORAGE
2147A
WORK ROOM
STORAGE
AUDIOLOGY
TEST BOOTH
AUDIOLOGY
2147E
2147C
TEST BOOTH
AUDIOLOGY
2147B
TEST BOOTH
AUDIOLOGY
ELECTRICAL CLOSET
2157A
STAIR-D
TEST BOOTH
AUDIOLOGY
TEST BOOTH
AUDIOLOGY
2179B
2179A
PIPE CHASE
2175A
WORKSTATION
2133D
HOUSEKEEPINGPIPE CHASE
2116A
2115A
PIPE CHASE
2101C
2101F
PIPE
CHASE
2124A
OFFICE
CAMERA ROOM
STORAGE
CORRIDOR
INJECTION
CAMERA ROOM
ROOM
OFFICES
OFFICES
2133B
BREAK
ROOM
A.D.
P-2
P-1
S-1
MECH.
ELECTRICAL
SHAFT
CART
LIFT
MECHANICAL
2F122
2F 139
2F 140
2225C
STOR
LAB
OFF
OFF
OFF
2233A
STOR
STAIR-G
HSKP
2236A
WORK RM
2240A
M LOCKER
2240B
F LOCKER
COOLER
OFFICE
WORK RM
FREEZERS
2241A
2241D
OFF
STOR
OFF
OFF
ELEC.
OFF
CONF.RM
STORAGE
PLEBOTOMY
TLT
TLT
SHOWER
STAIR-F
OFF
OFF
OFF
STAIR-H
TEL.
ELEC.
2240C
LOUNGE
TOILET
SERVER SCANNER
TOILET
SUPPLY CLO
DRESSING
RM-C
DRESSING
RM-A
TLT.
TLT.
2190A
WAITING
2198A
TLT.
HSKP
2200A
TLT
X-RAY
X-RAY
X-RAY
ULTRA SOUND
X-RAY
2208A
STOR
X-RAY
DRESSING
RM-B
SOILED
OFFICE
ELEC.
2F133
TOILET
TOILET
ROOF
ROOF
ROOF
BLOOD BANK
SEATING
UTILITY
VIEWING
EQUIP.
2204A
VESTIBULE
2204C
CT SCAN
CONTROL
2204B
STANDING
DOOR
INOPERABLE
PULMONARY
TEST
PULMONARY
LAB
ECHO LAB
STRESS LAB
OFFICE
OPEN TO BELOW
OPEN TO BELOW
LC
STAIR G
STAIR A
STAIR B
STAIR C
STAIR D
STAIR F
STAIR H
STAIR E
SCALE: 1/16" = 1'-0"
BLDG 1 - FLOOR 2
LC
8301 SQ FT
ZONE 1-2-A
4549 SQ FT
ZONE 1-2-B
9743 SQ FT
ZONE 1-2-C
8977 SQ FT
ZONE 2-2-B
STAIR J
OPEN TO BELOW
SCALE: 1/16" = 1'-0"
BLDG 2 - FLOOR 2
21792 SQ FT
ZONE 2-2-A
1-2-001, 1-2-002
1-2-003, 1-2-004, 1-2-005
1-2-006
1-2-007, 1-2-008
1-2-009
1-2-010
1-2-011
2-2-001
2-2-004
2-2-005
2-2-006
2-2-007, 2-2-008
2-2-009
2-2-010
2-2-011
2-2-013
2-2-012
1-2-012
2-2-014
2-2-002, 2-2-003
B
T
Project Number Office of
Construction and Facilities Management
Building Number
Revisions Date
Drawing Number
CONSULTANTS: ARCHITECTS/ENGINEERS:
1 & 2
VA CLARKSBURG
987654321
987654321
Project Title
Location
Date Checked Drawn
Drawing Title
Approved: Project Director
KEY PLAN
02/28/2020
1 Medical Center Drive, Clarksburg, WV 26301
SEAL
LS-1 2.2
LIFE SAFETY PLAN
BUILDING 1 & 2
FLOOR 2ART - ARCHITECTURE - ENGINEERING
2787 Hill Road Vienna, VA 22181
Phone: (703) 938-5226
Contact: Frank Sturgeon AIA, NCARB
A DESIGN GROUP, LLC
LEGEND
BUILDING SEPARATION
HORIZONTAL EXIT
3-HOUR FIRE BARRIER
2-HOUR FIRE BARRIER
1-HOUR FIRE BARRIER
30 MINUTE FIRE BARRIER
SMOKE BARRIER
SMOKE PARTITION
SMOKE RESISTIVE CORRIDOR WALL
EXIT
NON-PATIENT CARE OCCUPANCIES
HAZARDOUS AREA
NON-SLEEPING SUITE
NON-PATIENT SUITE
HORIZONTAL BARRIER TRANSFER
FIRE ALARM CONTROL PANEL
FIRE PUMP
TRASH CHUTE
SLEEPING SUITE
NON-SPRINKLER PROTECTED AREA
FP
LINEN CHUTE
TC
LC
FACP
540-20-110
FINAL 02/28/2020 RSM JLOTel: 703-717-5628
VIENNA, VA 22182
SUITE 355
8230 BOONE BLVD
CAPITOL FPE, LLC
CAPITOL FPE, LLC
AutoCAD SHX Text
SHELF
AutoCAD SHX Text
SHELF
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CHECK IN
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text one and one-half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text three-quarters inch = one foot
AutoCAD SHX Text one-half inch = one foot
AutoCAD SHX Text three-eighths inch = one foot
AutoCAD SHX Text one-quarter inch = one foot
AutoCAD SHX Text one-eighth inch = one foot
AutoCAD SHX Text 0 4 8 16
AutoCAD SHX Text 0 4 8
AutoCAD SHX Text 0 4
AutoCAD SHX Text 0 4
AutoCAD SHX Text 6" 0 2
AutoCAD SHX Text 6" 0 2
AutoCAD SHX Text 6" 0 1
3A109A
390A
FC
3B105
STAIR E
PIPE CHASE
MECH
3B141
STAIR D
FC
LINEN
CLEAN
SEMI-PRIVATE
PATIENT
RM
300B
CORRIDOR
3A129
SEMI-PRIVATE
PATIENT RM
3A148
SEMI-PRIVATE
PATIENT
RM
3A138
CLEAN UTILITY
3A137
DAY ROOM
3A139A
TOILET/
SHOWER
3A139
PRIVATE
PATIENT
RM
PIPE CHASE
3A140
PRIVATE
PATIENT
RM
3A140A
TOILET/
SHOWER
3A141
EXAM RM
3A146A
TOILET/
SHOWER
3A152A
TOILET/
SHOWER
3A151A
TOILET/
SHOWER
3A150
CLEAN UTILITY
3A149A
TOILET/
SHOWER
3A149
SEMI-PRIVATE
PATIENT
RM
3A148A
TOILET/
SHOWER
3A147
SOILED
UTILITY
3A146
PRIVATE
PATIENT RM
3A151
PRIVATE
PATIENT RM
3A152
PRIVATE
PATIENT RM
3A145
PRIVATE
PATIENT RM
3A145A
TOILET/
SHOWER
300F
CORRIDOR
3A153
NURSE
STATION
SOUTH
3A153A
EQUIP
STORAGE 2
3A143
ELECTRICAL
RM
3A144
OFFICE
100E
GURNEY
ALCOVE
300A
CORRIDOR
3A154
PUBLIC
TOILET
STAIR C
3A156
CHIEF
OFFICE
3A156A
TOILET
3A196
STAFF TOILET
CORRIDOR
300 E
3A158
STAFF
LOUNGE
3A102
MECH
RM
3A101
DATA CLOSET
3A104
HEAD NURSE
3A103
HOUSE KEEPING
AID CLOSET
3A106
MED RM
3A107
PRIVATE
PATIENT
RM
3A107A
TOILET/
SHOWER
3A108A
TOILET/
SHOWER
3A108
PRIVATE
PATIENT
RM
NURSE
STATION
NORTH
3A110
EQUIP
ALCOVE
3A111
DIET TECH
3A112
STAFF TOILET
3A113A
TOILET/
SHOWER
3A113
SEMI-PRIVATE
PATIENT RM
3A114
SEMI-PRIVATE
PATIENT RM
3A114A
TOILET/
SHOWER
3A115
PHYSICIAN
WORK RM
STAIR A
3A109
NURSE
STATION
NORTH
3A117
SOILED
UTILITY
3A198
WHEEL CHAIR
ALCOVE
PIPE CHASE
3A119A
TOILET/
SHOWER
3A119
ISOLATION
PATIENT
RM
3A120A
TOILET/
SHOWER
3A119B
ANTE
3A120
3A135
ELECTRICAL
CLOSET
3A124
NOURISHMENT
122B
TOILET/
SHOWER
3A122
ISOLATION
PATIENT
RM
3A121A
TOILET/
SHOWER
3A121
SEMI-PRIVATE
PATIENT
RM
3A125
PRIVATE
PATIENT RM
3A125A
TOILET/
SHOWER
3A134A
TOILET/SHOWER
3A134
PRIVATE
PATIENT
RM
3A126A
TOILET/
SHOWER
3A126
PRIVATE
PATIENT RM
3A133
3A133A
TOILET/
SHOWER
STAIR B
3A132A
TOILET/
SHOWER
3A131
NURSE SUB
STATION
3A130A
TOILET/
SHOWER
3A132
PRIVATE
PATIENT
RM
3A128
PRIVATE
PATIENT
RM
3A128A
TOILET/
SHOWER
3A129A
TOILET/
SHOWER
3A130
SEMI-PRIVATE
PATIENT RM
PRIVATE
PATIENT RM
F P CLOSET
3A111A
ELEVATOR
ELEVATOR
ELEVATOR
COILING DOOR
COILING DOOR
3B119
EXAM 10
CASTING/
3B118
EXAM 9
3B117
EXAM 8
3B116
EXAM 7
3B114
NURSE
C3 19
CORRIDOR
3B113
NOURISH.
3B115
ROOM
MED.
3B137
TLT.
PAT.
C3 18
CORRIDOR
3B109
STORAGE
C3 17
CORRIDOR
C3 16
CORRIDOR
C3 15
CORRIDOR
3B110
EXAM 4
3B111
EXAM 5
3B112
EXAM 6
3B108
EXAM 3
3B107
EXAM 2
3B106
EXAM 1
3B104
SOILED
3B102
OFFICE
PRE-OP NURSE
3B101
OFFICE
NURSE
3B100
WAITING
3B153
REGISTRATION
3B152
OFFICE
SCHEDULING
3B151
TLT.
MEN'S
3B150
TLT.
WOMEN'S
3B149
STORAGE
3B146
LOCKER
STAFF
3B147
SHOWER
STAFF
3B145
TLT.
PAT.
3B144
DRESS
3B142
NURSE
3B139
WAIT
SUB
3B140
EQUIPMENT
3B131
JAN.
C3 18.1
SCRUB
3B138
UTILITY
SOILED
3B136
GI #2
3B135
WORK
ANES
3B134
GI #1
3B132
SCOPE
CLEAN
3B133
PROCESSING
SCOPE
3B130
ROOM 4
PRIVATE
3B129
ROOM 3
PRIVATE
3B128
ROOM 2
PRIVATE
3B127
ROOM 1
PRIVATE
3B124
EXAM 14
3B123
EXAM 13
3B122
EXAM 12
3B121
EXAM 11
PRE-OP
143A
3A136
3A127A
3A100H
3A122A
CRASH
CRASH
ANTE
GURNEY ALCOVE
CART LITF
SHAFT
MECH.
S-1
P-2
P-1
3308A
3309A
3353A
335133493345
3338A
3325B
3325A
3316A
3315B
3315C
3315D
3315E
3315G
3315F
OR-4
LOCKER
TEL.
ELEC.
OFFICE
OFFICE
CONTROL
MED
HAC
SOILED
WAITING
STORAGE
ISOLATION
BED-11
BED-10
BED-9
BED-8
BED-7
BED-6
BED-5
ISOLATION
BED-3
BED-2
BED-1
OFFICE
NOURISH
OR-3
OR-2
HAC
OR-1
RM.
3329A
LINEN
F-1
STAIR-F
F-2
STAIR-H
LOUNGE
SOILED
UTILITY
3323A
CONTROL
O.R
WAITING
C3-1
ELEVATOR
LOBBY
C3-2
CORRIDOR
CONSULT
OFFICE
ANES
3320A
CRNA
C3 3B
CORRIDOR
STAFF
CRNA
LOCKERS
PAT.
COPY/FAX
STORAGE
EQUIPMENT
OFFICE
NURSE MGR.
3311A
CHART/NOURISH
OFFICE
RESIDENT
NURSE
TLT.
STAFF
TLT.
PAT.
ROOM 1
PRIVATE
ROOM 2
PRIVATE
ROOM 4
PRIVATE
ROOM 3
PRIVATE
C3 3
CORRIDOR
SERVICE
ELEV.LOBBY
ANES WORK
C3 3A
CORRIDOR
WOMEN
WOMEN
3308B
WOMEN
LOCKER
3309B
MEN
MEN TOILET
MEN
LOUNGE
CLEAN
STORAGE
CLEAN
WORK
3319A
ENDO
STORAGE
SCRUB
HAC
3316B
LAB
3321A
X-RAY
3319B
STERILE
SUB-
3321B
LAB
3321C
STORAGE
RECOVERY
C3-4
CORRIDOR
UTILITY
SOILED
F-3
STAIR-G
C3-9
CORRIDOR
ANTE
C3-10
CORRIDOR
C3-11
CORRIDOR
BED-15
BED-14
BED-13
C3-13
CORRIDOR
UTILITY
ANTE
C3-14
CORRIDOR
EQUIP
TOILET
C3-8
CORRIDOR
C3-12
CORRIDOR
TOILET
3357A
LOCKER
TEL
ELEC
3358A
TOILET
3F119
RECOVERY
C3 7
CORRIDOR
ANTE
C3 7A
NURSE
MED RM
CLEAN
UTILITY
C3-6
CORRIDOR
CLEAN
TOILET
ISOLATION
STORAGE
TOILET
ELECTRICAL
MECH SHAFT
LC
LC
9981 SQ FT
ZONE 1-3-A
6005 SQ FT
ZONE 1-3-B
9387 SQ FT
ZONE 1-3-C
15363 SQ FT
ZONE 2-3-A
8508 SQ FT
ZONE 2-3-B
STAIR A
STAIR B
STAIR C
STAIR E
STAIR F
STAIR H
STAIR G
STAIR D
SUITE 01
3012 SQ FT
SUITE 02
3306 SQ FT
SUITE 03
6786 SQ FT
SCALE: 1/16" = 1'-0"
BLDG 1 - FLOOR 3
SUITE 04
7301 SQ FT
SCALE: 1/16" = 1'-0"
BLDG 2 - FLOOR 3
1-3-001
1-3-002
1-3-003 1-3-004
1-3-005
1-3-006
1-3-007
2-3-001
2-3-002 2-3-003
2-3-004
2-3-007
2-3-009, 2-3-010
2-3-020
2-3-019
2-3-018
2-3-015, 2-3-016
2-3-017
2-3-011, 2-3-012, 2-3-013
2-3-014
2-3-008
2-3-006
2-3-005
1-3-008, 1-3-009
B
T
Project Number Office of
Construction and Facilities Management
Building Number
Revisions Date
Drawing Number
CONSULTANTS: ARCHITECTS/ENGINEERS:
1 & 2
VA CLARKSBURG
987654321
987654321
Project Title
Location
Date Checked Drawn
Drawing Title
Approved: Project Director
KEY PLAN
02/28/2020
1 Medical Center Drive, Clarksburg, WV 26301
SEAL
LS-1 2.3
LIFE SAFETY PLAN
BUILDING 1 & 2
FLOOR 3ART - ARCHITECTURE - ENGINEERING
2787 Hill Road Vienna, VA 22181
Phone: (703) 938-5226
Contact: Frank Sturgeon AIA, NCARB
A DESIGN GROUP, LLC
LEGEND
BUILDING SEPARATION
HORIZONTAL EXIT
3-HOUR FIRE BARRIER
2-HOUR FIRE BARRIER
1-HOUR FIRE BARRIER
30 MINUTE FIRE BARRIER
SMOKE BARRIER
SMOKE PARTITION
SMOKE RESISTIVE CORRIDOR WALL
EXIT
NON-PATIENT CARE OCCUPANCIES
HAZARDOUS AREA
NON-SLEEPING SUITE
NON-PATIENT SUITE
HORIZONTAL BARRIER TRANSFER
FIRE ALARM CONTROL PANEL
FIRE PUMP
TRASH CHUTE
SLEEPING SUITE
NON-SPRINKLER PROTECTED AREA
FP
LINEN CHUTE
TC
LC
FACP
540-20-110
FINAL 02/28/2020 RSM JLOTel: 703-717-5628
VIENNA, VA 22182
SUITE 355
8230 BOONE BLVD
CAPITOL FPE, LLC
CAPITOL FPE, LLC
AutoCAD SHX Text
4'HIGH
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
CRASH
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text one and one-half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text three-quarters inch = one foot
AutoCAD SHX Text one-half inch = one foot
AutoCAD SHX Text three-eighths inch = one foot
AutoCAD SHX Text one-quarter inch = one foot
AutoCAD SHX Text one-eighth inch = one foot
AutoCAD SHX Text 0 4 8 16
AutoCAD SHX Text 0 4 8
AutoCAD SHX Text 0 4
AutoCAD SHX Text 0 4
AutoCAD SHX Text 6" 0 2
AutoCAD SHX Text 6" 0 2
AutoCAD SHX Text 6" 0 1
REC
THERAPY
STORAGE
4B13
4B11
4B11A
4B40
4B10
4B45
STAIR-C
SHAFT
STAIR-E
P I P
E
C
H A
S E
4B09
ELEVATORELEVATOR ELEVATOR
4B42
STAIR-D
422A
WORKER
CHIEF SOCIAL
OFFICE
TOILET
STAFF
CLOSET
ELECTRICAL
LOUNGE
STAFF
4B12
STORAGE
PATIENT
MED RM
4B14
STATION
NURSE
4B15
PATIENT RM
SINGLE
4B15A
BATH
4B16
PATIENT RM
DOUBLE
4B16A
BATH
4B17
PATIENT RM
DOUBLE
4B17A
BATH
4B18A
BATH
4B18
PATIENT RM
DOUBLE
4B19
PATIENT RM
DOUBLE
4B19A
BATH
4B47
CLOSET
FP/FE
4B20
QUIET RM
4B21
CLOSET
MECH
4B22A
BATH
4B22
PATIENT RM
BARIATRIC
4B23A
HOLDING RM
4B23
ANTE RM
4B23B
TOILET
HOLDING
4B24A
STORAGE
MEDICAL
4B24C
TOILET
PUBLIC
UNI-SEX
4B24
VISITATION AREA
4B04
CORRIDOR
4B25
OFFICE
NURSE MGR
4B26
EXAM
4B27
LINEN
CLEAN
4B28
LINEN
SOILED
MECH
4B29
TOILET
PATIENT
4B30
NOURISHMENT
4B32A
ACCESS
TV
4B31
DINING
4B33A
GROUP RM
4B33B
DAY RM
4B34
HOUSEKEEPING
4B36
UTILITY
CLEAN
4B35
UTILITY
SOILED
4B37
CONFERENCE
STAFF
4B38
OFFICE
4B39
WORKER OFFICE
SHARED SOCIAL
4B32
STORAGE
4B41
CLOSET
FP/FE
4B01
CORRIDOR
4B02
CORRIDOR
4B03
CORRIDOR
4B08
CORRIDOR
SECRETARY
4A415
STAFF BREAK
4A412
PSYCH
OFFICE 2
4A420
ADMIN COPY
4A417
ADMIN
OFFICE
4A416
CHIEF OFFICE
4A414
PSYCH
OFFICE 1
4A413
CLOSET
4A419
ELEC CLOSET
4C467
MECHANICAL
ROOM
4C469
OFFICE 3
4A438
OFFICE 2
4A437
OFFICE 1
4A436
GROUP ROOM
4A407VIDEO/TESTING
4A422
OFFICE 24
4A424
OFFICE 23
4A425
OFFICE 22
4A426
OFFICE 21
4A427
OFFICE 20
4A429
OFFICE 19
4A430
GROUP ROOM
4A458
WC ALCOVE
4A406
ELECTRICAL
4A405
TREATMENT
ROOM
4A403
ELEC
4C492
4C489CCHV CRAFT
4C500
SPS OFFICE 2
4C497
SPS OFFICE 1
4C496
CWT OFFICE 1
4C476
CWT OFFICE 2
4C477
HOMELESS
COORD.
4C478
HUD/ BASH
4C479
HC TOILET
4C474
SPS OFFICE 3
4C498
F.P.
4C483
CHAPLAIN
OFFICE 2
4C494
CHAPLAIN
OFFICE 3
4C495
CHAPLAIN
OFFICE 1
4C480
CHIEF
CHAPLAIN
4C481
CHAPLAIN
RESIDENTS
4C482
OFFICE 14
4A455
VIDEO /
TESTING
4A454
OFFICE 14
4A453
OFFICE 13
4A452
OFFICE 12
4A451
OFFICE 11
4A450
OFFICE 10
4A449
OFFICE 9
4A448
OFFICE 8
4A447
OFFICE 7
4A445
OFFICE 6
4A444
OFFICE 5
4A443
OFFICE 4
4A442
COPY
4C484
MECH SHAFT
4A423
MECH SHAFT
4A464
CHASE
4C470
CHASE
4C468
RESOURCE
ROOM
4C487
RECEPTION
4A402
WAITING
4A401
TRIAGE/
PSYCH
NURSE
4A463
HC TOILET
4A460
HC TOILET
4A461
CWT
STUDENT
4C475
STORAGE
4A404
CLOSET
4A408
TEL. CL.
4C502
GROUP ROOM
4A459
F.P.
4A411
REC
THERAPY
4C486
HSKP
4A410
STAIR A
4A421
STAIR B
4A440
CORRIDOR
4A400
CORRIDOR
4A428
CORRIDOR
4A446
CORRIDOR
4A409
HALLWAY
4A418
ELEVATOR
LOBBY
4C465
ELEVATOR
LOBBY
4C490
ELEVATOR
LOBBY
4C472
CORRIDOR
4C473
CORRIDOR
4C493
CORRIDOR
4C501
CORRIDOR
4C485
F.P.
4A441
CRAFT
4C488
IT CLOSET
4C466
SHAFT
ELECTRICAL RM
MECH
S-1
P-2
P-1
4B43
STAIR-F
MECH RM
4B48
4B44
CORRIDOR
4B05
ELEVATOR LOBBY
4B06
ELEVATOR LOBBY
4B07
LC
STAIR A
STAIR B
STAIR C
STAIR D
STAIR F
STAIR E
10066 SQ FT
ZONE 1-4-A
6777 SQ FT
ZONE 1-4-B
9891 SQ FT
ZONE 1-4-C
5630 SQ FT
ZONE 2-4-A
SUITE 01
564 SQ FT
SUITE 02
3818 SQ FT
SCALE: 1/16" = 1'-0"
BLDG. 1 - FLOOR 4
OPEN TO BELOW
1-4-001
1-4-002
1-4-003
1-4-004
1-4-005 1-4-006
1-4-007
1-4-008
1-4-009
1-4-010
2-4-001, 2-4-002
2-4-003
SCALE: 1/16" = 1'-0"
BLDG. 2 - FLOOR 4
1-4-011
1-4-012
LC
B
T
Project Number Office of
Construction and Facilities Management
Building Number
Revisions Date
Drawing Number
CONSULTANTS: ARCHITECTS/ENGINEERS:
1 & 2
VA CLARKSBURG
987654321
987654321
Project Title
Location
Date Checked Drawn
Drawing Title
Approved: Project Director
KEY PLAN
02/28/2020
1 Medical Center Drive, Clarksburg, WV 26301
SEAL
LS-1 2.4
LIFE SAFETY PLAN
BUILDING 1 & 2
FLOOR 4ART - ARCHITECTURE - ENGINEERING
2787 Hill Road Vienna, VA 22181
Phone: (703) 938-5226
Contact: Frank Sturgeon AIA, NCARB
A DESIGN GROUP, LLC
LEGEND
BUILDING SEPARATION
HORIZONTAL EXIT
3-HOUR FIRE BARRIER
2-HOUR FIRE BARRIER
1-HOUR FIRE BARRIER
30 MINUTE FIRE BARRIER
SMOKE BARRIER
SMOKE PARTITION
SMOKE RESISTIVE CORRIDOR WALL
EXIT
NON-PATIENT CARE OCCUPANCIES
HAZARDOUS AREA
NON-SLEEPING SUITE
NON-PATIENT SUITE
HORIZONTAL BARRIER TRANSFER
FIRE ALARM CONTROL PANEL
FIRE PUMP
TRASH CHUTE
SLEEPING SUITE
NON-SPRINKLER PROTECTED AREA
FP
LINEN CHUTE
TC
LC
FACP
540-20-110
FINAL 02/28/2020 RSM JLOTel: 703-717-5628
VIENNA, VA 22182
SUITE 355
8230 BOONE BLVD
CAPITOL FPE, LLC
CAPITOL FPE, LLC
AutoCAD SHX Text
FOLDING
AutoCAD SHX Text
PARTITION
AutoCAD SHX Text
SUPPLY AIR CHASE
AutoCAD SHX Text
RETURN AIR CHASE
AutoCAD SHX Text
FEC
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text one and one-half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text three-quarters inch = one foot
AutoCAD SHX Text one-half inch = one foot
AutoCAD SHX Text three-eighths inch = one foot
AutoCAD SHX Text one-quarter inch = one foot
AutoCAD SHX Text one-eighth inch = one foot
AutoCAD SHX Text 0 4 8 16
AutoCAD SHX Text 0 4 8
AutoCAD SHX Text 0 4
AutoCAD SHX Text 0 4
AutoCAD SHX Text 6" 0 2
AutoCAD SHX Text 6" 0 2
AutoCAD SHX Text 6" 0 1
STAIR A
STAIR C
STAIR E
L C
L C
15545 SQ FT
ZONE 1-5-A
2448 SQ FT
ZONE 2-5-A
1-5-001
1-5-002
2-5-001
STAIR F
1-5-003
B
T
Project Number Office of
Construction and Facilities Management
Building Number
Revisions Date
Drawing Number
CONSULTANTS: ARCHITECTS/ENGINEERS:
1 & 2
VA CLARKSBURG
987654321
987654321
Project Title
Location
Date Checked Drawn
Drawing Title
Approved: Project Director
KEY PLAN
02/28/2020
1 Medical Center Drive, Clarksburg, WV 26301
SEAL
LS-1 2.5
LIFE SAFETY PLAN
BUILDING 1 & 2
FLOOR 5ART - ARCHITECTURE - ENGINEERING
2787 Hill Road Vienna, VA 22181
Phone: (703) 938-5226
Contact: Frank Sturgeon AIA, NCARB
A DESIGN GROUP, LLC
LEGEND
BUILDING SEPARATION
HORIZONTAL EXIT
3-HOUR FIRE BARRIER
2-HOUR FIRE BARRIER
1-HOUR FIRE BARRIER
30 MINUTE FIRE BARRIER
SMOKE BARRIER
SMOKE PARTITION
SMOKE RESISTIVE CORRIDOR WALL
EXIT
NON-PATIENT CARE OCCUPANCIES
HAZARDOUS AREA
NON-SLEEPING SUITE
NON-PATIENT SUITE
HORIZONTAL BARRIER TRANSFER
FIRE ALARM CONTROL PANEL
FIRE PUMP
TRASH CHUTE
SLEEPING SUITE
NON-SPRINKLER PROTECTED AREA
FP
LINEN CHUTE
TC
LC
FACP
SCALE: 3/32" = 1'-0"
BLDG 1 - FLOOR 5
SCALE: 3/32" = 1'-0"
BLDG 2 - FLOOR 5
540-20-110
FINAL 02/28/2020 RSM JLOTel: 703-717-5628
VIENNA, VA 22182
SUITE 355
8230 BOONE BLVD
CAPITOL FPE, LLC
CAPITOL FPE, LLC
PRODUCED BY AN AUTODESK STUDENT VERSION
P R
O D
U C
Y
A
N
A
U T
O D
E S
K
S
T U
D E
N T
V
R
S I O
N
PRODUCED BY AN AUTODESK STUDENT VERSION
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
ROOF
AutoCAD SHX Text 5A155
AutoCAD SHX Text
OFFICES
AutoCAD SHX Text
TEAM
AutoCAD SHX Text 5A154
AutoCAD SHX Text
CLOSET
AutoCAD SHX Text 5A153
AutoCAD SHX Text
SOILED
AutoCAD SHX Text 5A152
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
ONE
AutoCAD SHX Text 5A151A
AutoCAD SHX Text
BATH
AutoCAD SHX Text 5A152A
AutoCAD SHX Text
BATH
AutoCAD SHX Text 5A105
AutoCAD SHX Text
CORR.
AutoCAD SHX Text 5A151
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
TWO
AutoCAD SHX Text 5A150
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text 5A149
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
TWO
AutoCAD SHX Text 5A149A
AutoCAD SHX Text
BATH
AutoCAD SHX Text 5A148
AutoCAD SHX Text
HAC
AutoCAD SHX Text 5A147
AutoCAD SHX Text
STATION
AutoCAD SHX Text
NURSE
AutoCAD SHX Text 5A104
AutoCAD SHX Text
CORR.
AutoCAD SHX Text 5A157
AutoCAD SHX Text
ELECT.
AutoCAD SHX Text 5A156A
AutoCAD SHX Text
BATH
AutoCAD SHX Text 5A156
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
TWO
AutoCAD SHX Text 5A158
AutoCAD SHX Text
LINENS
AutoCAD SHX Text 5A159
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
ONE
AutoCAD SHX Text 5A159A
AutoCAD SHX Text
BATH
AutoCAD SHX Text 5A160
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
ONE
AutoCAD SHX Text 5A161A
AutoCAD SHX Text
BATH
AutoCAD SHX Text 5A161
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
TWO
AutoCAD SHX Text 5A146
AutoCAD SHX Text
SUPPLIES
AutoCAD SHX Text 5A145
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
ONE
AutoCAD SHX Text 5A144A
AutoCAD SHX Text
BATH
AutoCAD SHX Text 5A144
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
TWO
AutoCAD SHX Text 5A143
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
MEDICATION
AutoCAD SHX Text 5A142
AutoCAD SHX Text
CART
AutoCAD SHX Text
CRASH
AutoCAD SHX Text 5A141
AutoCAD SHX Text I.T.
AutoCAD SHX Text 5A140
AutoCAD SHX Text
TOILET
AutoCAD SHX Text
STAFF
AutoCAD SHX Text 5A100
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text 5E01
AutoCAD SHX Text
ELEV.
AutoCAD SHX Text
PUBLIC
AutoCAD SHX Text 5E02
AutoCAD SHX Text
ELEV.
AutoCAD SHX Text
STAFF
AutoCAD SHX Text 5E03
AutoCAD SHX Text
ELEV.
AutoCAD SHX Text
PUBLIC
AutoCAD SHX Text 5A101
AutoCAD SHX Text
CORR.
AutoCAD SHX Text 5A139
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text
STAFF
AutoCAD SHX Text 5A137
AutoCAD SHX Text
LOCKERS
AutoCAD SHX Text 5A138
AutoCAD SHX Text
ELECTRIC
AutoCAD SHX Text
EXIST.
AutoCAD SHX Text 5A136
AutoCAD SHX Text
BREAKROOM
AutoCAD SHX Text
STAFF
AutoCAD SHX Text 5A132
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
DINING
AutoCAD SHX Text 5A131
AutoCAD SHX Text
NOURISHMENT
AutoCAD SHX Text 5A130
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text 5A129
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
TWO
AutoCAD SHX Text 5A111A
AutoCAD SHX Text
BATH
AutoCAD SHX Text 5A111
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
BARIATRIC
AutoCAD SHX Text 5A112
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
ONE
AutoCAD SHX Text 5A112A
AutoCAD SHX Text
BATH
AutoCAD SHX Text 5A113
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
ONE
AutoCAD SHX Text 5A133
AutoCAD SHX Text
STOR.
AutoCAD SHX Text 5A110
AutoCAD SHX Text
LIVING ROOM
AutoCAD SHX Text 5A110A
AutoCAD SHX Text
COPY
AutoCAD SHX Text 5A109
AutoCAD SHX Text I.T.
AutoCAD SHX Text 5A114
AutoCAD SHX Text
DEN
AutoCAD SHX Text 5A115
AutoCAD SHX Text
STATION
AutoCAD SHX Text
NURSE
AutoCAD SHX Text 5A102
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text 5A103
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text 5A129A
AutoCAD SHX Text
BATH
AutoCAD SHX Text 5A128
AutoCAD SHX Text
TOILET
AutoCAD SHX Text
VISITOR
AutoCAD SHX Text 5A127A
AutoCAD SHX Text
BATH
AutoCAD SHX Text 5A127
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
TWO
AutoCAD SHX Text 5A126
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text 5A125
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
TWO
AutoCAD SHX Text 5A124A
AutoCAD SHX Text
BATH
AutoCAD SHX Text 5A124
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
ONE
AutoCAD SHX Text 5A119
AutoCAD SHX Text
SOILED
AutoCAD SHX Text 5A518
AutoCAD SHX Text
CLOSET
AutoCAD SHX Text 5A120
AutoCAD SHX Text
HAC
AutoCAD SHX Text 5A117
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text 5A116A
AutoCAD SHX Text
BATH
AutoCAD SHX Text 5A116
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
ONE ISO
AutoCAD SHX Text 5B100
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text 5B105
AutoCAD SHX Text
ELEC.
AutoCAD SHX Text
EXIST.
AutoCAD SHX Text 5B102
AutoCAD SHX Text
HALL
AutoCAD SHX Text
SERVICE
AutoCAD SHX Text 5E04
AutoCAD SHX Text
ELEV.
AutoCAD SHX Text
PUBLIC
AutoCAD SHX Text 5E05
AutoCAD SHX Text
ELEV.
AutoCAD SHX Text
PUBLIC
AutoCAD SHX Text 5E06
AutoCAD SHX Text
ELEV.
AutoCAD SHX Text
SERVICE
AutoCAD SHX Text 5B103
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text 5B101
AutoCAD SHX Text
LOBBY
AutoCAD SHX Text
EXIST. ELEV.
AutoCAD SHX Text
CHUTE
AutoCAD SHX Text
CHUTE
AutoCAD SHX Text
CHASE
AutoCAD SHX Text
CHASE
AutoCAD SHX Text
CHASE
AutoCAD SHX Text
CHASE
AutoCAD SHX Text
CHASE
AutoCAD SHX Text
FEC
AutoCAD SHX Text
CHASE
AutoCAD SHX Text
CHASE
AutoCAD SHX Text
FEC
AutoCAD SHX Text
FEC
AutoCAD SHX Text
MATERIAL
AutoCAD SHX Text
PRODUCT
AutoCAD SHX Text
TRADENAME
AutoCAD SHX Text
MODELNUMBER
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text one and one-half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text three-quarters inch = one foot
AutoCAD SHX Text one-half inch = one foot
AutoCAD SHX Text three-eighths inch = one foot
AutoCAD SHX Text one-quarter inch = one foot
AutoCAD SHX Text one-eighth inch = one foot
AutoCAD SHX Text 0 4 8 16
AutoCAD SHX Text 0 4 8
AutoCAD SHX Text 0 4
AutoCAD SHX Text 0 4
AutoCAD SHX Text 6" 0 2
AutoCAD SHX Text 6" 0 2
AutoCAD SHX Text 6" 0 1
AutoCAD SHX Text 6"
Capitol FPE02 Text Box
Capitol FPE02 Text Box
C65
TEL.CLO.
OFFICE
STAIR-C
STAIR C
STAIR E
C64
PT/OT
DIABETES EDUCATION
KITCHEN
OFFICE
TLT
WORK AREA
OFFICE
ROOM
LOCKER
A
P I P
E
C
H A
S
E MED RM
TLT
644A
TLT
645A
BED RM
B. RM
TLT
643A
TLT
642A
PT&OT
STORE
PIPE
CHASE
SOILED
UTILITY
STAIR E
F.CLO.
641A
SHARED OFFICE
B. RM
B. RM
B. RM
B.RM
B. RM
SUPPLY RM.
STORE
BED ROOM
TLT
614B
PIPE
CHASE
614A
SOILED
UTILITY
B.RM
TLT
610A
TLT
611A
B.RM
B.RM
TLT
608A
TLT
609A
B.RM
O.T&RECREATIONAL
THERAPY
NHCU
MED DIR.
OFF.
TLT
619A
B. RM
B.RM
TLT
620A
TLT
622A
B.RM
SOLARIUM
PIPE
CHASE
F.CLO.
613A
C63
C67
STAIR-A
TLT
TLT
TLT TLT
ELEVATORELEVATOR ELEVATOR
ELEVATORS
SHAFT
ELECTRICAL
MECH.
S-1
P-2
P-1
STAIR
OFFICE
C5 1
PASS.
C5 2
CORRIDOR
STAIR F-4
ELEVATOR
LOBBY
F-1
TLT
6600A-1
6600A
H.A.C.
HSKP
CLEAN
LINEN
627A
STAIR A
PENTHOUSE STAIR
STAIR F
L C
L C
9302 SQ FT
ZONE 1-6-A
4623 SQ FT
ZONE 1-6-B
2616 SQ FT
ZONE 2-6-A
1-6-001
1-6-002
B
T
Project Number Office of
Construction and Facilities Management
Building Number
Revisions Date
Drawing Number
CONSULTANTS: ARCHITECTS/ENGINEERS:
1 & 2
VA CLARKSBURG
987654321
987654321
Project Title
Location
Date Checked Drawn
Drawing Title
Approved: Project Director
KEY PLAN
02/28/2020
1 Medical Center Drive, Clarksburg, WV 26301
SEAL
LS-1 2.6
LIFE SAFETY PLAN
BUILDING 1 & 2
FLOOR 6ART - ARCHITECTURE - ENGINEERING
2787 Hill Road Vienna, VA 22181
Phone: (703) 938-5226
Contact: Frank Sturgeon AIA, NCARB
A DESIGN GROUP, LLC
LEGEND
BUILDING SEPARATION
HORIZONTAL EXIT
3-HOUR FIRE BARRIER
2-HOUR FIRE BARRIER
1-HOUR FIRE BARRIER
30 MINUTE FIRE BARRIER
SMOKE BARRIER
SMOKE PARTITION
SMOKE RESISTIVE CORRIDOR WALL
EXIT
NON-PATIENT CARE OCCUPANCIES
HAZARDOUS AREA
NON-SLEEPING SUITE
NON-PATIENT SUITE
HORIZONTAL BARRIER TRANSFER
FIRE ALARM CONTROL PANEL
FIRE PUMP
TRASH CHUTE
SLEEPING SUITE
NON-SPRINKLER PROTECTED AREA
FP
LINEN CHUTE
TC
LC
FACP
SCALE: 3/32" = 1'-0"
BLDG 1 - FLOOR 6
SCALE: 3/32" = 1'-0"
BLDG 2 - FLOOR 6
540-20-110
FINAL 02/28/2020 RSM JLOTel: 703-717-5628
VIENNA, VA 22182
SUITE 355
8230 BOONE BLVD
CAPITOL FPE, LLC
CAPITOL FPE, LLC
PRODUCED BY AN AUTODESK STUDENT VERSION
P R
O D
U C
A
N
A
U T
O D
E S
K
S
T U
D E
R
S I O
N
PRODUCED BY AN AUTODESK STUDENT VERSION
AutoCAD SHX Text
UP
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text one and one-half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text three-quarters inch = one foot
AutoCAD SHX Text one-half inch = one foot
AutoCAD SHX Text three-eighths inch = one foot
AutoCAD SHX Text one-quarter inch = one foot
AutoCAD SHX Text one-eighth inch = one foot
AutoCAD SHX Text 0 4 8 16
AutoCAD SHX Text 0 4 8
AutoCAD SHX Text 0 4
AutoCAD SHX Text 0 4
AutoCAD SHX Text 6" 0 2
AutoCAD SHX Text 6" 0 2
AutoCAD SHX Text 6" 0 1
AutoCAD SHX Text 6"
Capitol FPE02 Text Box
NORTH
PENTHOUSE
ROOF
CENTER PENTHOUSE
ROOF
ROOF
SOUTH
PENTHOUSE
STAIR F - 4
ELEV.MECH.ROOM
F7 100
ROOF
ROOF
ROOF
ELEVATOR EQUIPMENT
ELEVATOR ELECTRICAL
1049 SQ FT
ZONE 2-LP-A
440 SQ FT
ZONE 1-LP-A
438 SQ FT
ZONE 1-LP-C
1747 SQ FT
ZONE 1-LP-B
1354 SQ FT
ZONE 1-UP-A
B
T
Project Number Office of
Construction and Facilities Management
Building Number
Revisions Date
Drawing Number
CONSULTANTS: ARCHITECTS/ENGINEERS:
1 & 2
VA CLARKSBURG
987654321
987654321
Project Title
Location
Date Checked Drawn
Drawing Title
Approved: Project Director
KEY PLAN
02/28/2020
1 Medical Center Drive, Clarksburg, WV 26301
SEAL
LS-1 2.P
LIFE SAFETY PLAN
BUILDING 1 & 2
UPPER AND LOWER PENTHOUSESART - ARCHITECTURE - ENGINEERING
2787 Hill Road Vienna, VA 22181
Phone: (703) 938-5226
Contact: Frank Sturgeon AIA, NCARB
A DESIGN GROUP, LLC
LEGEND
BUILDING SEPARATION
HORIZONTAL EXIT
3-HOUR FIRE BARRIER
2-HOUR FIRE BARRIER
1-HOUR FIRE BARRIER
30 MINUTE FIRE BARRIER
SMOKE BARRIER
SMOKE PARTITION
SMOKE RESISTIVE CORRIDOR WALL
EXIT
NON-PATIENT CARE OCCUPANCIES
HAZARDOUS AREA
NON-SLEEPING SUITE
NON-PATIENT SUITE
HORIZONTAL BARRIER TRANSFER
FIRE ALARM CONTROL PANEL
FIRE PUMP
TRASH CHUTE
SLEEPING SUITE
NON-SPRINKLER PROTECTED AREA
FP
LINEN CHUTE
TC
LC
FACP
SCALE: 3/32" = 1'-0"
PENTHOUSES
540-20-110
FINAL 02/28/2020 RSM JLOTel: 703-717-5628
VIENNA, VA 22182
SUITE 355
8230 BOONE BLVD
CAPITOL FPE, LLC
CAPITOL FPE, LLC
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text one and one-half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text three-quarters inch = one foot
AutoCAD SHX Text one-half inch = one foot
AutoCAD SHX Text three-eighths inch = one foot
AutoCAD SHX Text one-quarter inch = one foot
AutoCAD SHX Text one-eighth inch = one foot
AutoCAD SHX Text 0 4 8 16
AutoCAD SHX Text 0 4 8
AutoCAD SHX Text 0 4
AutoCAD SHX Text 0 4
AutoCAD SHX Text 6" 0 2
AutoCAD SHX Text 6" 0 2
AutoCAD SHX Text 6" 0 1
112 111
103B
103C
OFFICE
QUIET
LIVING/DAY
DINING
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
TOILET
BEDROOM
BEDROOM
HALL
VESTIBULE
HALL
TOILET
LAUNDRY
HALL
CUSTOD.
TOILET
LINEN CLOS.
STOR.
TOILET
RAMP DOWN
R A
M P
O W
N
1 1/2"Ø HANDRAIL
ST-1
STAIR
DN
MECHANICAL
CHASE
1 1/2"Ø HANDRAIL
103A
HALL
UP
FUTURE
CLOSET
CLOSET
FUTURE
FUTURE
CLOSET
CLOSET
HALL
LINEN CLOS.
TOILET
STOR.
TOILET
357 SQ FT
ZONE 5-B-A
3052 SQ FT
ZONE 5-1-A
784 SQ FT
ZONE 5-2-A
5-B-001
5-1-001
B
T
Project Number Office of
Construction and Facilities Management
Building Number
Revisions Date
Drawing Number
CONSULTANTS: ARCHITECTS/ENGINEERS:
VA CLARKSBURG
987654321
987654321
Project Title
Location
Date Checked Drawn
Drawing Title
Approved: Project Director
KEY PLAN
02/28/2020
1 Medical Center Drive, Clarksburg, WV 26301
SEAL
LS-5
LIFE SAFETY PLAN
BUILDING 5
ART - ARCHITECTURE - ENGINEERING
2787 Hill Road Vienna, VA 22181
Phone: (703) 938-5226
Contact: Frank Sturgeon AIA, NCARB
A DESIGN GROUP, LLC
LEGEND
BUILDING SEPARATION
HORIZONTAL EXIT
3-HOUR FIRE BARRIER
2-HOUR FIRE BARRIER
1-HOUR FIRE BARRIER
30 MINUTE FIRE BARRIER
SMOKE BARRIER
SMOKE PARTITION
SMOKE RESISTIVE CORRIDOR WALL
EXIT
NON-PATIENT CARE OCCUPANCIES
HAZARDOUS AREA
NON-SLEEPING SUITE
NON-PATIENT SUITE
HORIZONTAL BARRIER TRANSFER
FIRE ALARM CONTROL PANEL
FIRE PUMP
TRASH CHUTE
SLEEPING SUITE
NON-SPRINKLER PROTECTED AREA
FP
LINEN CHUTE
TC
LC
FACP
SCALE: 1/8" = 1'-0"
BLDG. 5 - BASEMENT
SCALE: 1/8" = 1'-0"
BLDG. 5 - FLOOR 1
SCALE: 1/8" = 1'-0"
BLDG. 5 - FLOOR 2
540-20-110
FINAL 02/28/2020 RSM JLOTel: 703-717-5628
VIENNA, VA 22182
SUITE 355
8230 BOONE BLVD
CAPITOL FPE, LLC
CAPITOL FPE, LLC
PRODUCED BY AN AUTODESK STUDENT VERSION
P R
O D
U C
A
N
A
U T
O D
E S
K
S
T U
D E
R
S I O
N
PRODUCED BY AN AUTODESK STUDENT VERSION
AutoCAD SHX Text
AutoCAD SHX Text
CRAWLSPACE
AutoCAD SHX Text
AutoCAD SHX Text
CRAWLSPACE
AutoCAD SHX Text
AutoCAD SHX Text
CRAWLSPACE
AutoCAD SHX Text
AutoCAD SHX Text
CRAWLSPACE
AutoCAD SHX Text
AutoCAD SHX Text
CRAWLSPACE
AutoCAD SHX Text
AutoCAD SHX Text
CRAWLSPACE
AutoCAD SHX Text
AutoCAD SHX Text
CRAWLSPACE
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text one and one-half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text three-quarters inch = one foot
AutoCAD SHX Text one-half inch = one foot
AutoCAD SHX Text three-eighths inch = one foot
AutoCAD SHX Text one-quarter inch = one foot
AutoCAD SHX Text one-eighth inch = one foot
AutoCAD SHX Text 0 4 8 16
AutoCAD SHX Text 0 4 8
AutoCAD SHX Text 0 4
AutoCAD SHX Text 0 4
AutoCAD SHX Text 6" 0 2
AutoCAD SHX Text 6" 0 2
AutoCAD SHX Text 6" 0 1
AutoCAD SHX Text 6"
Capitol FPE02 Text Box
UP
Entry 22101
Common Space 22102
Dirty Linen 22103
Stair 22111
Mech 22112
W/D 22113
Shared Work Area
22114
JC
22115
Mech
Passage 22117
Quiet Space 22121
Bed Room 22122
Lav 22123
Bath 22124
Bedroom 22125
Lav 22126
Bath 22127
Quiet Space 22131
ADA/Bariatric 22132
ADA Bath 22133
Bed Room 22135
Lav 22136
Bath 22137
3177 SQ FT
ZONE 22-1-A
22-2-001
UP
Basement 22014
Storage 22015
Storage 22016
Storage 22013
Storage 22012
Stair 22011
AHU
RE: MECH
TYP
TYP
1423 SQ FT
ZONE 22-B-A
UP
Stair 22211
Mech
W/D 22213
Shared Work Area
22214
JC
22215
Mech
Passage 22217
Quite Space 22221
Bed Room 22222
Lav 22223
Bath 22224
Bed Room 22225
Lav 22226
Bath 22227
Quiet Space 22231
Bed Room 22232
Lav 22233
Bath 22234
Bed Room 22235
Lav 22236
Bath 22237
2284 SQ FT
ZONE 22-2-A
22-2-001
B
T
Project Number Office of
Construction and Facilities Management
Building Number
Revisions Date
Drawing Number
CONSULTANTS: ARCHITECTS/ENGINEERS:
VA CLARKSBURG
987654321
987654321
Project Title
Location
Date Checked Drawn
Drawing Title
Approved: Project Director
KEY PLAN
02/28/2020
1 Medical Center Drive, Clarksburg, WV 26301
SEAL
LS-22.0
LIFE SAFETY PLAN
BUILDING 22
ART - ARCHITECTURE - ENGINEERING
2787 Hill Road Vienna, VA 22181
Phone: (703) 938-5226
Contact: Frank Sturgeon AIA, NCARB
A DESIGN GROUP, LLC
LEGEND
BUILDING SEPARATION
HORIZONTAL EXIT
3-HOUR FIRE BARRIER
2-HOUR FIRE BARRIER
1-HOUR FIRE BARRIER
30 MINUTE FIRE BARRIER
SMOKE BARRIER
SMOKE PARTITION
SMOKE RESISTIVE CORRIDOR WALL
EXIT
NON-PATIENT CARE OCCUPANCIES
HAZARDOUS AREA
NON-SLEEPING SUITE
NON-PATIENT SUITE
HORIZONTAL BARRIER TRANSFER
FIRE ALARM CONTROL PANEL
FIRE PUMP
TRASH CHUTE
SLEEPING SUITE
NON-SPRINKLER PROTECTED AREA
FP
LINEN CHUTE
TC
LC
FACP
SCALE: 1/8" = 1'-0"
BLDG. 22 - FLOOR 1
SCALE: 1/8" = 1'-0"
BLDG. 22 - BASEMENT
SCALE: 1/8" = 1'-0"
BLDG. 22 - FLOOR 2
540-20-110
FINAL 02/28/2020 RSM JLOTel: 703-717-5628
VIENNA, VA 22182
SUITE 355
8230 BOONE BLVD
CAPITOL FPE, LLC
CAPITOL FPE, LLC
PRODUCED BY AN AUTODESK STUDENT VERSION
P R
O D
U C
A
N
A
U T
O D
E S
K
S
T U
D E
R
S I O
N
PRODUCED BY AN AUTODESK STUDENT VERSION
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text one and one-half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text three-quarters inch = one foot
AutoCAD SHX Text one-half inch = one foot
AutoCAD SHX Text three-eighths inch = one foot
AutoCAD SHX Text one-quarter inch = one foot
AutoCAD SHX Text one-eighth inch = one foot
Aut…