This document package includes construction drawings and a federal contract opportunity. The construction drawings depict partition details, wall sections, and other architectural elements for a medical facility renovation project. The federal contract opportunity is a solicitation by the Department of Veterans Affairs for repair work related to water damage at the Louis A. Johnson VA Medical Center in Clarksburg, West Virginia. The contractor will be responsible for providing all labor, supervision, materials, equipment, and tools to correct deficiencies in the Purple Firm building due to water damage. All work must be completed within 120 calendar days and comply with infection prevention requirements. Work hours will be from 7am to 5pm Monday through Friday, with potential flexibility, and requests for work outside these hours must be submitted to the contracting officer's representative 72 hours in advance.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
01_FIRST FLOOR
1002' - 8"
02_SECOND FLOOR
1014' - 0 1/2"
00_LOWER LEVEL
990' - 10 1/8"
A7
00_1947 BASEMENT
991' - 6 1/8"
A5-2
4SIM
A5-2
3SIM
1'-7 1/2" 1'-0"
1/2" 1'-0"
1/2" 1'-0"
1/2" 1'-0"
1/2" 1'-0"
1/2" 1'-0"
1/2" 1'-0"
1/2" 1'-0"
1/2" 1'-0"
1/2" 1'-0"
1/2" 1'-0"
1/2" 1'-0"
1/2" 1'-0"
8"
(TYP)
GLASS FIBER
REINFORCED
CONCRETE PANEL
FLASHING
FACE BRICK TO STRUCTURAL
SHELF BELOW GRADE
PERIMETER
FOUNDATION
DRAINS (TYP)
METAL COPING
11'-4 1/2" 2'-11"
11'-1 7/8" 8"
8" 1'-0"
14'-3 1/2"
BRICK TIE
SLOPED GRADE
PREMOLDED
EXPANSION JOINT
SINGLE PLY
ROOFING WITH
TAPERED
INSULATION
CAST IN PLACE
STRUCTURE,
REFER TO
STRUCTURAL
DRAWINGS
SCHEDULED
CEILING, SEE RCP
CAST IN PLACE
STRUCTURE,
REFER TO
STRUCTURAL
DRAWINGS
SCHEDULED
CEILING, SEE RCP
1 LAYER 5/8" GWB
3 5/8" MTL. STUDS AT
16" O.C. W/ R19 BATT
INSUL.
MTL. STUD TRACK
STEEL BASE PLATE
5/8" EXTERIOR
SHEATHING
GRAVEL INFIL
RIGID INSULATION
VAPOR BARRIER
CAST IN PLACE
STRUCTURUAL
SLAB, REFER TO
STRUCTURAL
DRAWINGS
5/8" GWB ON 1/2"
STUD
01_FIRST FLOOR
1002' - 8"
02_SECOND FLOOR
1014' - 0 1/2"
00_LOWER LEVEL
990' - 10 1/8"
A7
3'-0"
A5-2
A5-2
SINGLE PLY
ROOFING WITH
TAPERED
INSULATION
CAST IN PLACE
STRUCTURE,
REFER TO
STRUCTURAL
DRAWINGS
SCHEDULED
CEILING, SEE RCP
CAST IN PLACE
STRUCTURE,
REFER TO
STRUCTURAL
DRAWINGS
SCHEDULED
CEILING, SEE RCP
CAST IN PLACE
STRUCTURE,
REFER TO
STRUCTURAL
DRAWINGS
CAST IN PLACE
STRUCTURUAL
SLAB, REFER TO
STRUCTURAL
DRAWINGS
GLASS FIBER
REINFORCED
CONCRETE PANEL
FLASHING
BRICK TIE
PERIMETER
FOUNDATION
DRAINS (TYP)
METAL COPING
11'-4 1/2" 2'-11"
11'-9 7/8" 8"
1'-0"
CURTAIN WALL
SYSTEM WITH 1"
INSULATED GLAZING
3'-9 1/2" 6'-3"
14'-3 1/2"
PREMOLDED
EXPANSION JOINT
FACE BRICK TO STRUCTURAL
SHELF BELOW GRADE
SLOPED GRADE
1 LAYER 5/8" GWB
3 5/8" MTL. STUDS AT
16" O.C. W/ R19 BATT
INSUL.
MTL. STUD TRACK
STEEL BASE PLATE
5/8" EXTERIOR
SHEATHING
01_FIRST FLOOR
1002' - 8"
A7
2" 10 1/2"
1/2"
(TYP)
1'-0" 1/2"
9 5/8" 1 1/2"
GLASS FIBER REINFORCED
CONCRETE PANEL
MEMBRANE FLASHING WITH
METAL DRIP EDGE
6" COLD FORMED METAL
FRAMING
5/8" PAINTED GYPSUM
BOARD
SOLID SURFACE WINDOW
SILL (TYP)
BATT INSULATION
FLUID APPLIED MEMBRANE
AIR BARRIER
C PROFILE RAIL
FACE BRICK
AIR SPACE
GROUT SOLID
THROUGH WALL FLASHING
WITH METAL DRIP EDGE
STOREFRONT SYSTEM WITH
1" INSULATED GLAZING
STOREFRONT SILL PAN
FLASHING (TYP) FLASHING WITH METAL DRIP
EDGE, PAINT TO MATCH
WALL PANEL
WALL ANCHOR CLIP
MTL. STUD TRACK
CAST IN PLACE CONCRETE
STRUCTURE, REFER TO
STRUCTURAL DRAWINGS
5/8" EXTERIOR SHEATHING
8"
VAR
IES
3'-9 1/2"
BRICK TIE
SLOPED GRADE
SCHEDULED BASE
STEEL BASE PLATE
3" CONTINUOUS INSULATION
02_SECOND FLOOR
1014' - 0 1/2"
A7 SLOPE
GLASS FIBER
REINFORCED
CONCRETE PANEL
WALL ANCHOR CLIP
C PROFILE RAIL
FLUID APPLIED
MEMBRANE AIR
BARRIER
METAL COPING
6"4"
1 1/2"
1"
SINGLE PLY
ROOFING ON
TAPERED
INSULATION
EXTERIOR
SHEATHING
TREATED BLOCKING
CAST IN PLACE
CONCRETE
STRUCTURE. REFER
TO STRUCTURAL
LIGHT GUAGE
FRAMING W/
PAINTED DRYWALL
SOFFITS CONTINUOUS
SOFFIT VENT
1/2"
STOREFRONT SYSTEM
WITH 1" INSULATED
GLAZING
11" 1/2"
1'-0" 1/2"
1'-0" 1/2"
1'-0"
MEMBRANE TO
EXTEND AROUND
BLOCKING FOR
COPING.
ROOFING MEMBRANE
TO OVER LAP FLUID
APPLIED AIR BARRIER
(TYP)
RUN ROOFING UP AND
OVER PARAPET,
OVERLAP WITH FLUID
APPLIED AIR BARRIER
WALL SECTIONS AND DETAILS
A5-2 SASJJM
SCALE: 3/4" = 1'-0" 1WALL SECTION
SCALE: 3/4" = 1'-0" 2WALL SECTION
SCALE: 1 1/2" = 1'-0" 3DETAIL - CONC. PANEL AT WINDOW SILL
SCALE: 1 1/2" = 1'-0" 4DETAIL - CONC. PANEL AT WINDOW - HEAD
BID SET
Project Number Office of
Construction and Facilities Management
Building Number
RevisionsDate
Drawing Number
VA FORM 08-6231
CONSULTANTS:ARCHITECTS/ENGINEERS:ARCHITECTURAL PROJECT #
VA CLARKSBURG
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rte rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rte r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
F
E
D
C
B
A
9 8 7 6 5 4 3 2 1
9 8 7 6 5 4 3 2 1
Project Title
Location
DateCheckedDrawn
Drawing Title
Approved: Project Director
7850 Freeway Circle
440.243.2000 t
Cleveland, OH 44130
440.243.3305 f
KEY PLAN TRUE NORTH
PROJECT NORTH
AREA OF WORK
25% CONSTRUCTION DOCUMENTS09/12/14
50% CONSTRUCTION DOCUMENTS04/28/16
540-325
AMB CARE SUPPORT/PHYS.
SECURITY IMPROVEMENTS
11/30/2016
1 Medical Center Drive, Clarksburg, WV 26301
19200.00
100% CONSTRUCTION DOCUMENTS
REVISED SCHEMATIC DESIGN SUBMISSION03/20/14
75% CONSTRUCTION DOCUMENTS07/12/16
100% CONSTRUCTION DOCUMENTS10/06/16
100% CONSTRUCTION DOCUMENTS11/30/16
SEAL
01_FIRST FLOOR
1002' - 8"
02_SECOND FLOOR
1014' - 0 1/2"
03_THIRD FLOOR
1025' - 5"
UPPER CANOPY
1014' - 8"
LOWER CANOPY
1012' - 8"
A1
PERIMETER
FOUNDATION
DRAINS (TYP)
A5-2
3SIM
A5-4
A5-3
SCHEDULED CEILING GLASS FIBER REINFORCED CONCRETE PANEL
(JOINTS ALIGN AROUND ENTIRE PROJECT)
ALUMINUM CURTAIN WALL SYSTEM
WITH INSULATED GLAZING (TYP)
STRUCTURAL SLAB
ON GRADE
ALUMINUM CURTAIN WALL SYSTEM
WITH INSULATED GLAZING (TYP)
AUTOMATIC CONTROLLED SHADE
POCKET, REFER TO ELECTRICAL
DRAWINGS
FIRESTOPPING
CLEAR ANODIZED GRAVEL STOP
TREATED BLOCKINGSINGLE PLY ROOFING ON
TAPERED INSULATION (TYP).
WRAP UP AND OVER
BLOCKING.
10'-0" 2'-8"
1'-4 1/2" 7 1/2"
10'-9" 4'-4 1/2"
BRICK TIE
FLASHING WITH METAL DRIP EDGE
GLASS FIBER REINFORCED
CONCRETE PANEL
FLASHING WITH METAL DRIP EDGE,
PAINT TO MATCH WALL PANEL
C PROFILE RAIL
WALL ANCHOR CLIP
FLUID APPLIED MEMBRANE
AIR BARRIER
SOLID SURFACE WINDOW SILL (TYP)
6" COLD FORMED METAL FRAMING
5/8" PAINTED GYPSUM BOARD
27'-1 1/2"
PREMOLDED
EXPANSION JOINT
SLOPED GRADE
FACE BRICK1 LAYER 5/8" GWB
3 5/8" MTL. STUDS AT
16" O.C. W/ R19 BATT
INSUL.
MTL. STUD TRACK
STEEL BASE PLATE
5/8" EXTERIOR
SHEATHING
C.F.M.F. KICKER
01_FIRST FLOOR
1002' - 8"
03_THIRD FLOOR
1025' - 5"
A5-3
A5-3
LOWER CANOPY
1012' - 8"
AE AD.5
8" 3"
8'-11 3/4" 2 1/2"
4'-3" 2 1/2"
6'-11 3/4" 2 1/2"
4'-9" 3"
ALUMINUM CURTAIN WALL
SYSTEM WITH INSULATED
GLAZING (TYP)
AUTOMATIC CONTROLLED
SHADE POCKET, REFER TO
ELECTRICAL DRAWINGS
CAST IN PLACE CONCRETE
STRUCTURE. REFER TO
STRUCTURAL DRAWINGS
SLAB ON GRADE, REFER TO
STRUCTURAL
PERIMETER
FOUNDATION
DRAINS (TYP)
STRUCTURAL FOUNDATION
SYSTEM, REFER TO
STRUCTURAL DRAWINGS
FIRESTOPPING
8'-7 1/8" 4'-1 5/8"
2'-8" 4'-4 1/2"
SINGLE PLY ROOFING ON
TAPERED INSULATION (TYP).
WRAP UP AND OVER
BLOCKING.
FACE BRICK
17'-1 1/4"
SLOPED GRADE
PREMOLDED
EXPANSION JOINT
C.F.M.F. KICKER
CONT. GALV. 6x3 1/2x5/16
W/ 5/8" Ø EPOXY ANCHORS
03_THIRD FLOOR
1025' - 5"
AE
6"
2 1/2" 6'-11 3/4"
2 1/2" 4'-9"
3"
ALUMINUM CURTAIN WALL
SYSTEM WITH INSULATED
GLAZING (TYP)
AUTOMATIC CONTROLLED SHADE
POCKET, REFER TO ELECTRICAL
DRAWINGS
SINGLE PLY ROOFING
ON TAPERED
INSULATION (TYP)
CAST IN PLACE
CONCRETE
STRUCTURE. REFER
TO STRUCTURAL
DRAWINGS
FIRESTOPPING
CLEAR ANODIZED
GRAVEL STOP
TREATED BLOCKINGWRAP ROOFING UP
AND OVER BLOCKING
C.F.M.F. KICKER
01_FIRST FLOOR
1002' - 8"
CONC. CURB TO SUPPORT
CURTAIN WALL. SEE STRUCTURAL
SCHEDULED BASE
STRUCTURAL SLAB ON GRADE
W/ PERIMETER INSULATION.
REFER TO STRUCTURAL
ALUMINUM CURTAIN WALL
SYSTEM WITH INSULATED
GLAZING (TYP)
CURTAIN WALL
FLASHING W/ METAL
DRIP EDGECONT. GALV. 6x3 1/2x5/16
W/ 5/8" Ø EPOXY ANCHORS
CAST IN PLACE CONCRETE
FOOTING. REFER TO
STRUCTURAL
FACE BRICK
CONTINUOUS
WATER PROOFING
MEMEBRANE.
INTEGRATE WITH
VAPOR BARRIER
SILL
7/8" CHANNEL AND 5/8" GWB
PREMOLDED EXPANSION JOINT
WALL SECTIONS AND DETAILS
A5-3 SASJJM
05'10'15'
SCALE: 1/8" = 1'-0"
SCALE: 3/4" = 1'-0" 1WALL SECTION
SCALE: 3/4" = 1'-0" 2WALL SECTION
SCALE: 1 1/2" = 1'-0" 3DETAIL - PARAPET AT CURTAINWALL
SCALE: 1 1/2" = 1'-0" 4DETAIL - BASE AT CURTAINWALL
BID SET
Project Number Office of
Construction and Facilities Management
Building Number
RevisionsDate
Drawing Number
VA FORM 08-6231
CONSULTANTS:ARCHITECTS/ENGINEERS:ARCHITECTURAL PROJECT #
VA CLARKSBURG
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rte rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rte r in c h o n e fo o t o n e e ig h th in c h o n e fo o
F
E
D
C
B
A
9 8 7 6 5 4 3 2 1
9 8 7 6 5 4 3 2 1
Project Title
Location
DateCheckedDrawn
Drawing Title
Approved: Project Director
7850 Freeway Circle
440.243.2000 t
Cleveland, OH 44130
440.243.3305 f
KEY PLAN TRUE NORTH
PROJECT NORTH
AREA OF WORK
25% CONSTRUCTION DOCUMENTS09/12/14
50% CONSTRUCTION DOCUMENTS04/28/16
540-325
AMB CARE SUPPORT/PHYS.
SECURITY IMPROVEMENTS
11/30/2016
1 Medical Center Drive, Clarksburg, WV 26301
19200.00
100% CONSTRUCTION DOCUMENTS
REVISED SCHEMATIC DESIGN SUBMISSION03/20/14
75% CONSTRUCTION DOCUMENTS07/12/16
100% CONSTRUCTION DOCUMENTS10/06/16
100% CONSTRUCTION DOCUMENTS11/30/16
SEAL
4 7/8" 4 7/8"
PARTITION TYPE 'A'
ONE HOUR RATED (U.L. #U465)
(1) LAYER OF 5/8" FIRE RESISTIVE GYP. BD. ON
EACH SIDE OF 3 5/8" STL. STUDS @ 16" O.C.
PARTITION TYPE 'B'PARTITION TYPE 'C'PARTITION TYPE 'D' NON-RATED
(1) LAYER OF 5/8" GYP. BD. ON EACH
SIDE OF 3 5/8" STL. STUD @ 16"O.C.
NON-RATED
(1) LAYER OF 5/8" GYP. BD. ON EACH
SIDE OF 3 5/8" METAL STUD @ 16"O.C.
HEAD OF PARTITION
METAL DECK PERPENDICULAR TO FLUTES
HEAD OF PARTITION
METAL DECK PARALLEL TO FLUTES
PARTITION AT FLOOR
PARTITION AT CEILING
HEAD OF PARTITION
PARTITION AT FLOOR
PARTITION AT FLOOR
PARTITION AT CEILING
PARTITION AT FLOOR
NON-RATED
(1) LAYER OF 5/8" GYP. BD. ON EACH
SIDE OF 6" METAL STUD @ 16"O.C.
ONE HOUR RATED (U.L. #U465)
(1) LAYER OF 5/8" FIRE RESISTIVE GYP. BD.
ON EACH SIDE OF 6" STL. STUDS @ 16" O.C.
PARTITION TYPE 'A1'
HEAD OF PARTITION
CONCRETE SLAB
STRUCTURE ABOVE
DEFLECTION JOINT
CONTINUOUS RUNNER TRACK
CONTINUOUS
ACOUSTICAL SEALANT
CEILING SYSTEM
CONT. RUNNER TRACK
STRUCTURE ABOVE
FINISHED SIDE
INFILL VOID AREAS
W/ SOUND BLANKET
CONTINUOUS RUNNER TRACK
FIRESTOP JOINT BETWEEN
TOP OF FIRE-RATED
PARTITION AND
STRUCTURE ABOVE W/ U.L.
OR W.H.I. PPROVED (1) HR.
JOINT FIRESTOP SYSTEM.
3 1/2" SOUND
ATTENUATION
BLANKET MAY OCCUR
CONTINUOUS
ACOUSTICAL SEALANT
EACH SIDE
CONTINUOUS
ACOUSTICAL
SEALANT
CONTINUOUS
RUNNER TRACK
CEILING
STRAP BRIDGING
STRUCTURE ABOVE
EXTEND GYP.
BD. 6" ABOVE
CEILING
DEFLECTION JOINT
CONT. RUNNER TRACK STRUCTURE ABOVE
SMOKESTOP ALL VOID
AREAS TIGHT TO
UNDERSIDE OF
STRUCTURE W/ SAFING
CONTINUOUS
ACOUSTICAL
SEALANT
DEFLECTION JOINT CONTINUOUS
RUNNER TRACK
STRUCTURE ABOVE
STRUCTURE ABOVE
DEFLECTION JOINT
DEFLECTION JOINT
14 GA. STL PLATE AS REQ.
(2) LAYERS OF 1/2" GYP. BD.
(2) LAYERS OF 1/2" GYP. BD.
25 GA. "C" STUDS
24" O.C.
25 GA. "C" STUDS
24" O.C.
"J" SHAPED RUNNER
1" GYP.
WALLBOARD
LINER PANELS
"J" SHAPED RUNNER
FINISH SIDE
CONTINUOUS ACOUSTIC
SEALANT EACH SIDE
(2) LAYERS OF 1/2" GYP. BD.
(2) LAYERS OF 1/2" GYP. BD. 25 GA. "C" STUDS
24" O.C.
STRUCTURE ABOVE
"J" SHAPED RUNNER
EXISTING CONSTR. OR
NEW MASONRY OR
CONC. CONSTR. (SEE
PLANS FOR SPECIFIC
CONDITIONS)
SOUND ATTENUATION
BLANKET MAY OCCUR
CONTINUOUS ACOUSTICAL
SEALANT
SOUND
ATTENUATION
BLANKET MAY
OCCUR
HEAD OF PARTITION
METAL DECK PERPENDICULAR TO FLUTES
HEAD OF PARTITION
METAL DECK PARALLEL TO FLUTES
HEAD OF PARTITION
CONCRETE SLAB
HEAD OF PARTITION
METAL DECK PERPENDICULAR TO FLUTES
HEAD OF PARTITION
METAL DECK PARALLEL TO FLUTES
4 7/8"
3 1/2" SOUND
ATTENUATION
BLANKET MAY OCCUR
3 1/2" SOUND
ATTENUATION
BLANKET MAY OCCUR
CONTINUOUS RUNNER TRACK
CONTINUOUS RUNNER TRACK
FIRESTOP JOINT BETWEEN
TOP OF FIRE-RATED
PARTITION AND
STRUCTURE ABOVE W/ U.L.
OR W.H.I. PPROVED (1) HR.
JOINT FIRESTOP SYSTEM.
CONTINUOUS
ACOUSTICAL SEALANT
EACH SIDE
CONTINUOUS RUNNER TRACK
CEILING
EXTEND GYP. BD. 6"
ABOVE CEILING, BOTH
SIDES
CONTINUOUS RUNNER TRACK
DEFLECTION JOINT
STRUCTURE ABOVE
STRAP BRIDGING
3 1/2" SOUND
ATTENUATION
BLANKET MAY OCCUR
CONTINUOUS
ACOUSTICAL SEALANT
EACH SIDE
STRUCTURE ABOVE
3 1/2" SOUND
ATTENUATION
BLANKET MAY OCCUR
CONTINUOUS RUNNER TRACK
CONTINUOUS
RUNNER TRACKDEFLECTION JOINT
STRUCTURE ABOVE
CONTINUOUS
RUNNER TRACK
DEFLECTION JOINT
3 1/2" SOUND
ATTENUATION
BLANKET MAY OCCUR
DEFLECTION JOINT
14 GA. STEEL
PLATE AS
REQUIRED
CONTINUOUS
ACOUSTICAL SEALANT
EACH SIDE
STRUCTURE ABOVE
CONTINUOUS
RUNNER TRACK
3 1/2" SOUND
ATTENUATION
BLANKET MAY OCCUR
CONTINUOUS
RUNNER TRACK
3 1/2" SOUND
ATTENUATION
BLANKET MAY OCCUR
EXTEND GYP. BD. 6"
ABOVE CEILING, THIS
SIDE
3 1/2" SOUND
ATTENUATION
BLANKET MAY OCCUR
CONTINUOUS ACOUSTICAL
SEALANT EACH SIDE
3 1/2" SOUND
ATTENUATION
BLANKET MAY OCCUR
3 1/2" SOUND
ATTENUATION
BLANKET MAY OCCUR
PARTITION TYPE 'C1'
4 1/4"1 1/2"3 1/2"
EXISTING CONSTR. OR
NEW MASONRY OR
CONC. CONSTR. (SEE
PLANS FOR SPECIFIC
CONDITIONS)
EXISTING CONSTR. OR
NEW MASONRY OR
CONC. CONSTR. (SEE
PLANS FOR SPECIFIC
CONDITIONS)
EXISTING CONSTR. OR
NEW MASONRY OR
CONC. CONSTR. (SEE
PLANS FOR SPECIFIC
CONDITIONS)
CEILING
EXTEND GYP.
BD. 6" ABOVE
CEILING
CONTINUOUS
ACOUSTICAL
SEALANT
FIRESTOP JOINT BETWEEN
TOP OF FIRE-RATED PARTITION
AND STRUCTURE ABOVE W/
U.L. OR W.H.I. APPROVED (2)
HR. JOINT FIRESTOP SYSTEM
1" GYP.
WALLBOARD
LINER PANELS
25 GA. "C" STUDS
24" O.C.
STRUCTURE ABOVE
"J" SHAPED RUNNER 1" GYP.
WALLBOARD
LINER PANELS
FIRESTOP JOINT BETWEEN
TOP OF FIRE-RATED PARTITION
AND STRUCTURE ABOVE W/
U.L. OR W.H.I. APPROVED (2)
HR. JOINT FIRESTOP SYSTEM
1" GYP. WALLBOARD
LINER PANELS
PARTITION TYPE 'G'
NON-RATED
(1) LAYER OF 5/8" GYP. BD. ON ONE SIDE OF
3 5/8" METAL STUD FURRING @ 16" O.C.
PARTITION TYPE 'H'
TWO HOUR RATED SHAFT WALL (U.L. #U438)
(2) LAYERS OF 1/2" FIRE RESISTIVE GYP. BD. ON
FINISHED SIDE OF 25 GA. STL. C-STUDS @ 24" O.C.
WITH 1" THICK GYP. BD. LINER PANELS ON SHAFT SIDE
PARTITION TYPE 'K'
NON-RATED
(1) LAYER OF 5/8" GYP. BD. ON ONE SIDE OF
7/8" METAL FURRING @ 16" O.C.
NON-RATED
(1) LAYER OF 5/8" GYP. BD. ON ONE SIDE
OF 2 1/2" METAL STUD FURRING @ 16" O.C.
PARTITION TYPE 'G1'
PARTITION AT FLOORPARTITION AT FLOORPARTITION AT FLOOR
HEAD OF PARTITION
METAL DECK PARALLEL TO FLUTES PARTITION AT CEILING PARTITION AT CEILING
HEAD OF PARTITIONHEAD OF PARTITION
METAL DECK PERPENDICULAR TO FLUTES
HEAD OF PARTITION
CONCRETE SLAB
NON-RATED
(1) LAYER OF 5/8" GYP. BD. ON ONE SIDE
OF 3 5/8" METAL STUDS @ 16" O.C.
ONE HOUR RATED SHAFT WALL (U.L. #U438)
(1) LAYERS OF 1/2" FIRE RESISTIVE GYP. BD. ON
FINISHED SIDE OF 25 GA. STL. C-STUDS @ 24" O.C.
WITH 1" THICK GYP. BD. LINER PANELS ON SHAFT SIDE
PARTITION TYPE 'K1' PARTITION TYPE 'B1'
NON-RATED
(1) LAYER OF 5/8" GYP. BD. ON EACH
SIDE OF 6" STL. STUD @ 16"O.C.
STRUCTURE ABOVE
DEFLECTION JOINT
STRUCTURE ABOVE
DEFLECTION JOINT
CONTINUOUS RUNNER
TRACK
STRUCTURE ABOVE
DEFLECTION JOINT
FIRESTOP JOINT BETWEEN
TOP OF FIRE-RATED PARTITION
AND STRUCTURE ABOVE W/
U.L. OR W.H.I. APPROVED (2)
HR. JOINT FIRESTOP SYSTEM
CONTINUOUS RUNNER TRACK
CONTINUOUS RUNNER TRACK
6 1/8"
CONTINUOUS
ACOUSTICAL
SEALANT
3 1/2" SOUND
ATTENUATION
BLANKET MAY
OCCUR
3 1/2" SOUND
ATTENUATION
BLANKET MAY
OCCUR
3 1/2" SOUND
ATTENUATION
BLANKET MAY
OCCUR
3 1/2" SOUND
ATTENUATION
BLANKET MAY
OCCUR
FIRESTOP JOINT BETWEEN
TOP OF FIRE-RATED PARTITION
AND STRUCTURE ABOVE W/
U.L. OR W.H.I. APPROVED (2)
HR. JOINT FIRESTOP SYSTEM
CONTINUOUS RUNNER
TRACK
CONTINUOUS
ACOUSTICAL
SEALANT
PARTITION TYPE 'J'
TWO HOUR RATED (U.L. #U411)
(2) LAYERS OF 5/8" FIRE RESISTIVE GYP. BD.
ON EACH SIDE OF 3 5/8" METAL STUDS @
16" O.C.
PARTITION AT FLOOR
HEAD OF PARTITION
METAL DECK PARALLEL TO FLUTES
HEAD OF PARTITION
METAL DECK PERPENDICULAR TO FLUTES
HEAD OF PARTITION
CONCRETE SLAB
4 1/4"
NON-RATED
(1) LAYER OF 5/8" GYP. BD. ON ONE SIDE
OF 1 5/8" METAL STUD FURRING @ 16" O.C.
PARTITION TYPE 'G2'
8" LIGHTWEIGHT CMU
FULL HEIGHT W/ MTL.
HORIZ. WALL REINF.
EVERY OTHER COURSE
STRUCTURE ABOVE
STRUCTURE ABOVE
10 GA. STL. PLATE
8"L AT 4'-0" O.C.
WIDTH MAY VARY
DEPENDING ON
FLUTE LOCATIONS
STRUCTURE ABOVE
COMPRESSIBLE MATERIAL
COMPRESSIBLE MATERIAL
BEYOND AT EACH FLUTE
5X3X3/8" X 8" LLV (TYP.
EACH SIDE OF WALL)
5X3X3/8" X 8" LLV AT 4'-0" MAX.
WITH (2) - 1/2" DIA. EXP.
ANCHORS WITH MIN. 3 1/2"
EMBED. (DO NOT CUT
REINF.) (TYP. EACH SIDE OF
WALL)
FIRESTOP JOINT BETWEEN
TOP OF FIRE-RATED
PARTITION AND STRUCTURE
ABOVE W/ U.L. OR W.H.I.
APPROVED JOINT FIRESTOP
SYSTEM MATCHING WALL
RATING.
8" LIGHTWEIGHT CMU
FULL HEIGHT W/ MTL.
HORIZ. WALL REINF.
EVERY OTHER COURSE
8" LIGHTWEIGHT CMU
FULL HEIGHT W/ MTL.
HORIZ. WALL REINF.
EVERY OTHER COURSE
FIRESTOP JOINT BETWEEN
TOP OF FIRE-RATED
PARTITION AND STRUCTURE
ABOVE W/ U.L. OR W.H.I.
APPROVED JOINT FIRESTOP
SYSTEM MATCHING WALL
RATING.
5X3X3/8" X 8" LLV (TYP.
EACH SIDE OF WALL)
FIRESTOP JOINT BETWEEN
TOP OF FIRE-RATED
PARTITION AND STRUCTURE
ABOVE W/ U.L. OR W.H.I.
APPROVED JOINT FIRESTOP
SYSTEM MATCHING WALL
RATING.
8" LIGHTWEIGHT CMU
FULL HEIGHT W/ MTL.
HORIZ. WALL REINF.
EVERY OTHER COURSE
ONE & TWO HOUR RATED (U.L. #U905)
THREE HOUR RATED (U.L. #U904)
PARTITION TYPE 'M'
PARTITION AT FLOOR
HEAD OF PARTITION
METAL DECK PARALLEL TO FLUTES
HEAD OF PARTITION
METAL DECK PERPENDICULAR TO FLUTES
HEAD OF PARTITION
CONCRETE SLAB
NON-RATED
(1) LAYER OF 5/8" GYP. BD. ON ONE
SIDE OF 2 1/2" METAL STUD @ 16"O.C.
PARTITION TYPE 'D1'
8" LIGHTWEIGHT CMU
FULL HEIGHT W/ MTL.
HORIZ. WALL REINF.
EVERY OTHER COURSE
STRUCTURE ABOVE
STRUCTURE ABOVE
COMPRESSIBLE MATERIAL
BEYOND AT EACH FLUTE
5X3X3/8" X 8" LLV (TYP.
EACH SIDE OF WALL)
5X3X3/8" X 8" LLV AT 4'-0" MAX.
WITH (2) - 1/2" DIA. EXP.
ANCHORS WITH MIN. 3 1/2"
EMBED. (DO NOT CUT
REINF.) (TYP. EACH SIDE OF
WALL)
FIRESTOP JOINT BETWEEN
TOP OF FIRE-RATED
PARTITION AND STRUCTURE
ABOVE W/ U.L. OR W.H.I.
APPROVED JOINT FIRESTOP
SYSTEM MATCHING WALL
RATING.
8" LIGHTWEIGHT CMU
FULL HEIGHT W/ MTL.
HORIZ. WALL REINF.
EVERY OTHER COURSE
FIRESTOP JOINT BETWEEN
TOP OF FIRE-RATED
PARTITION AND STRUCTURE
ABOVE W/ U.L. OR W.H.I.
APPROVED JOINT FIRESTOP
SYSTEM MATCHING WALL
RATING.
8" LIGHTWEIGHT CMU
FULL HEIGHT W/ MTL.
HORIZ. WALL REINF.
EVERY OTHER COURSE
(1) LAYER OF 5/8" GYP. BD. ON ONE
SIDE OF 7/8" METAL FURRING @ 16" O.C.
ONE & TWO HOUR RATED (U.L. #U905)
THREE HOUR RATED (U.L. #U904)
PARTITION TYPE 'N'
PARTITION AT FLOOR
HEAD OF PARTITION
METAL DECK
HEAD OF PARTITION
CONCRETE SLAB
8" LIGHTWEIGHT CMU
FULL HEIGHT W/ MTL.
HORIZ. WALL REINF.
EVERY OTHER COURSE
PARTITION AT CEILING
CEILING
EXTEND GYP.
BD. 6" ABOVE
CEILING
PARTITION TYPE 'H1'
TWO HOUR RATED WALL (U.L. #U905)
(2) LAYERS OF 5/8" GYP. BD. ON ONE SIDE OF
7/8" METAL FURRING @ 16" O.C.
1.
2.
3.
4.
5.
REFER TO REFLECTED CEILING PLANS FOR LOCATION OF SOUND ATTENUATION
BLANKETS.
REFER TO FINISH SCHEDULE FOR LOCATION OF MOISTURE RESISTANT BOARD
AND CEMENT BOARD.
PROVIDE DEFLECTION JOINT AS REQUIRED BY FIRESTOPPING SYSTEM USED AT
TOP OF RATED PARTITIONS.
SECURE STUDS IN FIRE RATED PARTITION SYSTEM AS REQUIRED BY
FIRESTOPPING SYSTEM USED AT TOP OF RATED PARTITIONS.
WOOD USED FOR FRAMING AND BLOCKING SHALL BE FIRE-RETARDANT
TREATED WOOD, U.L. LABLED
PARTITION TYPES
A10-4
PARTITION TYPES
PARTITION GENERAL NOTES
BID SET
Project Number Office of
Construction and Facilities Management
Building Number
RevisionsDate
Drawing Number
VA FORM 08-6231
CONSULTANTS:ARCHITECTS/ENGINEERS:ARCHITECTURAL PROJECT #
VA CLARKSBURG
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rte rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rte r in c h o n e fo o t o n e e ig h th in c h o n e fo o
F
E
D
C
B
A
9 8 7 6 5 4 3 2 1
9 8 7 6 5 4 3 2 1
Project Title
Location
DateCheckedDrawn
Drawing Title
Approved: Project Director
7850 Freeway Circle
440.243.2000 t
Cleveland, OH 44130
440.243.3305 f
KEY PLAN TRUE NORTH
PROJECT NORTH
AREA OF WORK
25% CONSTRUCTION DOCUMENTS09/12/14
50% CONSTRUCTION DOCUMENTS04/28/16
540-325
AMB CARE SUPPORT/PHYS.
SECURITY IMPROVEMENTS
11/30/2016
1 Medical Center Drive, Clarksburg, WV 26301
19200.00
100% CONSTRUCTION DOCUMENTS
REVISED SCHEMATIC DESIGN SUBMISSION03/20/14
75% CONSTRUCTION DOCUMENTS07/12/16
100% CONSTRUCTION DOCUMENTS10/06/16
100% CONSTRUCTION DOCUMENTS11/30/16
SEAL
REINFORCING / MOUNTING PLATE AT BARIATRIC GRAB BARS
1/8" = 1'-0"
TYPICAL REINFORCING / MOUNTING PLAT
1/8" = 1'-0"
SASJJM