This document contains a presolicitation notice and description for an Indefinite-Delivery Indefinite-Quantity contract for asbestos, mold, and lead abatement services. The Department of Veterans Affairs Veterans Integrated Service Network 5 intends to award multiple IDIQ contracts to provide abatement services for VA medical facilities in Maryland, West Virginia, Washington D.C., and associated community-based clinics. The contracts will have a one-year base period and four one-year options, with an overall value between $15 million. Individual task orders will have a minimum value of $2,000 and maximum of $500,000. This is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses. Interested firms must be registered in the System for Award Management and VetBiz databases under NAICS code 562910. The solicitation is expected to be available for download on January 6, 2020, with questions due to the email address provided. No telephone inquiries will be accepted.
36C24519R0111 0001 P11 Attachment 3_VISN 5 Bid Price Schedule_Quan_OPT-YR3.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24519R0111-0008000.docx | DOCX document | |
| 36C24519R0111-0007000.docx | DOCX document | |
| 36C24519R0111-0006000.docx | DOCX document | |
| 36C24519R0111-0006001.pdf | ||
| 36C24519R0111-0005000.docx | DOCX document | |
| 36C24519R0111-0004001.pdf | ||
| 36C24519R0111-0004000.docx | DOCX document | |
| 36C24519R0111-0003000.docx | DOCX document | |
| S06 36C24519R0111 0002.pdf | ||
| 36C24519R0111-0001018.pdf | ||
| 36C24519R0111-0001016.pdf | ||
| 36C24519R0111-0001017.pdf | ||
| 36C24519R0111-0001020.pdf | ||
| 36C24519R0111-0001014.docx | DOCX document | |
| 36C24519R0111-0001015.pdf | ||
| 36C24519R0111-009.pdf | ||
| 36C24519R0111-015.pdf | ||
| 36C24519R0111-017.pdf | ||
| 36C24519R0111-013.pdf | ||
| 36C24519R0111-007.docx | DOCX document | |
| 36C24519R0111-016.pdf | ||
| 36C24519R0111-012.pdf | ||
| 36C24519R0111-014.pdf | ||
| 36C24519R0111-010.pdf | ||
| 36C24519R0111-011.pdf | ||
| 36C24519R0111-008.pdf |
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BID ITEMS
No. 0A Work Description Units Qty $/Unit Total
0A1* Re-Mobilization to remove containment on project after TEM clearance results
EA 2
0A2*
Laboratory testing of bulk samples by PLM Method — Testing/ Estimating/Emergency Response
EA 10
0A3 Labor to take and deliver bulk samples - Testing/ Estimating/ Emergency Response
EA 10
0A4 Cleaning of Surfaces. Special cleaning of contaminated surfaces SF 1400
0A5 Remove asbestos insulation from ductwork SF 3000
0A6 Wrap and cut and remove insulated ductwork. SF 3000
0A7 Remove asbestos mastic from ductwork or pipe insulation SF 870
0A8 Remove asbestos from fittings and valves, up to 4" diameter pipe EA 69
0A9 Remove asbestos from fittings and valves, 6" to 8" diameter pipe, IPS EA 34
0A10 Remove asbestos from fittings and valves, 10" — 12" diameter pipe, IPS
EA 27
0A11 Bulk Asbestos Removal — Remove fireproofing from flat surface
SF 1380
0A12 Bulk Asbestos Removal — Remove fireproofing from irregular surface
SF 690
0A13
Bulk Asbestos Removal — Remove plaster ceiling, including suspension system, plaster & lathe SF 690
0A14 Remove Asbestos from Pipe by Glove Bag (pipe up to 3" IPS) LF 140
0A15 Remove Asbestos from Pipe by Glove Bag (pipe 3.5" to 8" diameter, IPS)
LF 90
0A16 Remove Asbestos from Fittings and Valves by Glove Bag (up to
8", IPS)
EA 9
0A17 Remove Asbestos pipe support blocks, bottom half of pipe at supports.
EA 9
OPTION YEAR 3 ASBESTOS ABATEMENT
MATERIALS/EQUIPMENT — UNIT PRICING
0A18 Remove Asbestos Cement Board SF 70
0A19* Disposal asbestos waste in certified landfill loads less than 5
CY
CY 44
0A20* Disposal asbestos waste in certified landfill loads greater than 5 CY
TON 10
0A21 Remove Asbestos from Pipe in containment, up to 4" diameter pipe, IPS
LF 140
0A22 Remove Asbestos from pipe in containment, 4" to 8" diameter pipe, IPS
LF 90
0A23 Remove Asbestos from pipe in containment, 10" to 12" diameter pipe/IPS
LF 70
0A24 Remove Asbestos from pipe in containment, 14" to 16" diameter pipe/IPS
LF 35
0A25 Remove/Replace Asbestos Flexible Duct Connection (up to 24"duct)
SF 300
0A26 Removal of fiberglass batt insulation up to 12" thick SF 70
0A27 Removal of up to 12" thick fiberglass blown-in insulation in attic.
SF 70
0A28
Install ANSI/OSHA approved identification labels, tags and/or signs where asbestos remains EA 70
0A29 Apply penetrating encapsulant on ceiling and other structural surfaces
SF 700
0A30 Seal exposed ends of asbestos pipe insulation. EA 35
0A31 Spray apply one (1) coat of penetrating encapsulant — Flat surface
SF 700
0A32 Spray apply one (1) coat of penetrating encapsulant — Pipes, beams, columns, tanks
SF 700
0A33 Remove of floor tiles or carpet and remove mastic with chemicals SF 3000
0A34 Remove floor tiles — each additional layer SF 3000
0A35 Remove of linoleum and remove mastic with chemicals SF 3000
0A36
Remove windows and perimeter sealant as asbestos & install temporary protection in opening with plywood and studs — Wrap, seal as asbestos and/or lead paint or both
SF of rough opng
0A37 Remove asbestos containing caulking exterior of building first floor or on scaffolding
LF 3000
0A38 Excavate and remove contaminated dirt, by hand — Crawl Space
CU. FT. 850
0A39
In a crawl space, remove debris, flatten contaminated earth, pour a fiber reinforced, 3" thick 3000 psi concrete slab, float finish. All equipment including concrete pump.
SF 2500
0A40 Contaminated Waste: Bag, Remove from work area. BAG 2500
0A41 Contaminated Waste Wrapped Items Remove from work area EA 1290
0A42 Excavate and remove contaminated dirt, by hand — Crawl Space
CU. FT. 690
0A43 Remove vinyl wall base & asbestos glue LF 470
0A44 Remove mastic by HEPA filtered bead blasting rather than chemicals
SF 3000
No. 0B Work Description Units Qty $/Unit Total
0B1 Abrasive Blasting flat, round, shaped SF 170
0B2 Chemical stripping larger areas not covered below SF 170
0B3 Chemical Stripping - paint from Window Sash SF 170
0B4 Chemical Stripping - paint from Window Sill LF 170
0B5 Scrape & Encapsulate - paint on Window Sash SF 170
0B6 Scrape & Encapsulate - paint on Window Sills LF 170
0B7 Scrape & Encapsulate - paint on masonry SF 170
0B8 Power Tool Cleaning SF 170 0B9 Encapsulation SF 170
0B10 Removal of material- Trim LF 70
* Line items that do not require time and one half have been identified via asterisks on the rate schedule.
Note to CONTRACTOR: Asbestos abatement in the medical center often occurs in the evenings and weekends to accommodate patients and staff. Identify a multiplier (if any) to be applied to base unit prices for work beyond normal hours (8 am. — 4:30 pm.).
LEAD CONTAINING PAINT ABATEMENT
MATERIALS/EQUIPMENT- UNIT PRICING
0B11 Removal of material- Drywall SF 140
0B12
Remove windows with lead containing paint & install temporary protection in opening with plywood and studs — Wrap, seal as containing lead paint
SF of rough opng
0B13 Removal of abandoned pipe or de-energized conduit > 4” dia LF 70
0B14 Removal of abandoned pipe or de-energized conduit < 4” dia LF 35
0B15 TCLP sampling of waste EA 9
0B16
Seal hazardous waste in DOT-standard 55 gal drums, store, transport, and disposal in a licensed landfill
DRUM 9
0B17 Loading for transport and disposal waste in a truck or dumpster CY 17
No. 0C Work Description Units Qty $/Unit Total
0C1 Removal of Material-Drywall on studs or furring SF 1400
0C2 Removal of Material-Carpet & glue SF 170
0C3 Removal of Material -Carpet Tile & glue SF 170
0C4 Removal of Material-VCT & glue
SF 480
0C5 Removal of Material-Linoleum & glue SF 480
0C6 Removal of Material-Ceramic Tile SF 35
0C7 Removal of Material - Plywood on floor or wall SF 350
0C8 Removal of Material- Contaminated Fiberglass Batt Insulation up to 6" thick
SF 350
0C9 Removal of Contaminated Fiberglass Insulation 7" up to 12" thick
SF 350
0C10 Removal of up to 12" thick fiberglass blown-in insulation in attic.
SF 70
0C11 Mold Remediation/Removal on Concrete Wall or Floor SF 340
0C12 Mold Remediation/Removal on Drywall SF 690
0C13 Multiplier for Off-Hours - Outside
8AM - 4:30PM 0
MOLD ABATEMENT MATERIALS/EQUIPMENT-
UNIT PRICING
No. 0D Work Description Units Qty $/Unit Total
0D1* Mobilization on projects. Work area isolation EA 2
0D2* Mobilization on projects. No work area isolation EA 1
0D3* Emergency Response EA 1 0D4* Work Plan EA 3
0D5 Elevated Work Surfaces in containment. Scaffolding (per SF floor area)
Per SF Floor Area 260
0D6 HEPA negative air machine (each) Per WEEK 87
0D7 Cleaning of Surfaces. Pre-cleaning, HEPA vacuum & wet wiping
SF 13800
0D8
Decontamination System. 2" x 4" @ 16", 5/8" plywood each side — 3 Stage Personal Decontamination Chamber with shower
EA 2
0D9
Decontamination System.
Disposable 3-stage decontamination system including shower
EA 2
0D10 Install and Remove Temporary Partition with 2" x 4" @ 16" studs and plastic sheeting
SF of Partition 350
0D11
Install and Remove Temporary 1Hr. Fire Rated Partition with 2" x 4" @ 16" studs & 5/8" drywall on each side, joints taped and fire caulking, one self closing locking door
SF of Partition 3500
0D12
Sealing and Protecting the Work Area on existing wall surfaces— Masking and sealing surfaces, each layer, 6-mil poly sheeting.
SF of Surface
ea. Layer 13800
0D13
Sealing and Protecting the Work Area on existing ceiling surfaces— Masking and sealing surfaces, each layer, 6-mil poly sheeting.
SF of Surface
ea. Layer 13800
0D14
Sealing and Protecting the Work Area — Protect carpeted area, 2 layers 6-mil poly on 3/4" plywood SF 1700
0D15 Containment Wall (5/8" plywood or drywall ea. side), 2' x 4" @ 16"
— 8 ft. high
SF of Partition 350
ITEMS COMMON TO ASBESTOS, LEAD, AND
MOLD ABATEMENT MATERIALS/EQUIPMENT-
UNIT PRICING
0D16 Containment Wall (5/8" plywood or drywall ea. side), 2' x 4" @ 16"
— 12 ft. high
SF of Partition 350
0D17 Containment Wall (5/8" plywood or drywall ea. side), 2' x 4" @ 16" —16 ft. high
SF of Partition 350
0D18*
Exterior (or interior) 1/2 in. x 48
in. x 96 in. Cellular White PVC Panel on studs or furring (intended for transite replacement). Exterior grade caulking all joints and seams.
SF 350
0D19* General non-HAZMAT waste haul and disposal charges - Loads greater than 5 CY
Per Ton 10
0D20* General waste non-HAZMAT haul and disposal charges - Loads less than 5 CY
Per CY 44
0D21 Truck and temporary storage of small quanties of hazardous waste in a secure location.
Per CY 44
0D22 Install new commercial carpet tile, 24 x 24 SY 170
0D23 Install new commercial carpet SY 170
0D24 Install new commercial floor tile, 12" x 12" SF 170
0D25 Install new 5/8" drywall over studs or furring (not incl.), tape and finish.
SF of D.W. 1380
0D26 Install new 3 1/2" metal or wood studs @ 16" o.c. for walls up to 10' high.
SF of Wall 1380
0D27 Painting, new, on drywall or masonry, 3 coats.
SF of Wall 1380
0D28 Patching drywall damaged in abatement or removing base, ready for Paint
SF of patch 170
0D29 Insulate F.G. w/ PVC Jacket fittings and valves, up to 4" diameter pipe, IPS
EA 70
0D30 Insulate F.G. w/ PVC Jacket fittings and valves, 6" to 8" diameter pipe, IPS
EA 34
0D31 Insulate F.G. w/ PVC Jacket fittings and valves, 10" — 12" diameter pipe, IPS
EA 27
0D32 Insulate 2" F.G. w/ PVC Jacket Pipe, up to 4" diameter pipe, IPS LF 140
0D33 Insulate 2" F.G. w/ PVC Jacket Pipe, 5" to 8" diameter pipe/Iron Pipe Size IPS
LF 86
0D34 Replacement Material- Fiberglass Batt Insulation up to 6" thick SF 345
0D35 Replacement Material Fiberglass Insulation 7" up to 12" thick SF 345
0D36 Replacement Material up to 12" thick fiberglass blown-in insulation in attic.
SF 70
0D37
New pipe support blocks, bottom half of pipe at supports, and new pipe insulation shields. Nominal pipe size 6".
EA 9
TOTALS
OPTION YEAR 3