NCO 5 Asbestos Lead Mold IDIQ
Solicitation number
36C24519R0111
Issued by

About this file

This document provides details for an indefinite delivery, indefinite quantity contract opportunity for asbestos, lead, and mold abatement services. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 5 is seeking proposals for on-going abatement work located within medical facilities in Maryland, West Virginia, Washington D.C., and associated community based clinics. The NAICS code is 562910 for remediation services. The small business size standard is $36.5 million. The base period of the contract is one year with four one-year options. Individual task orders will have a minimum value of $2,000 and maximum of $500,000. As this is a 100% set-aside, only Service-Disabled Veteran-Owned Small Businesses may apply. The pre-solicitation notice provides relevant details on registration requirements, with the solicitation package to be available on or after January 6, 2020. Questions should be directed via email with the specified subject line.

36C24519R0111 0001 P11 Attachment 3_VISN 5 Bid Price Schedule_Quan_OPT-YR1.pdf

View the file

Other files

File Type Posted
36C24519R0111-0008000.docx DOCX document
36C24519R0111-0007000.docx DOCX document
36C24519R0111-0006000.docx DOCX document
36C24519R0111-0006001.pdf PDF
36C24519R0111-0005000.docx DOCX document
36C24519R0111-0004001.pdf PDF
36C24519R0111-0004000.docx DOCX document
36C24519R0111-0003000.docx DOCX document
S06 36C24519R0111 0002.pdf PDF
36C24519R0111-0001018.pdf PDF
36C24519R0111-0001016.pdf PDF
36C24519R0111-0001020.pdf PDF
36C24519R0111-0001014.docx DOCX document
36C24519R0111-0001019.pdf PDF
36C24519R0111-0001015.pdf PDF
36C24519R0111-009.pdf PDF
36C24519R0111-015.pdf PDF
36C24519R0111-017.pdf PDF
36C24519R0111-013.pdf PDF
36C24519R0111-007.docx DOCX document
36C24519R0111-016.pdf PDF
36C24519R0111-012.pdf PDF
36C24519R0111-014.pdf PDF
36C24519R0111-010.pdf PDF
36C24519R0111-011.pdf PDF
36C24519R0111-008.pdf PDF
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BID ITEMS

No. 0A Work Description Units Qty $/Unit Total

0A1* Re-Mobilization to remove containment on project after TEM clearance results

EA 2

0A2*

Laboratory testing of bulk samples by PLM Method — Testing/ Estimating/Emergency Response

EA 10

0A3 Labor to take and deliver bulk samples - Testing/ Estimating/ Emergency Response

EA 10

0A4 Cleaning of Surfaces. Special cleaning of contaminated surfaces SF 1400

0A5 Remove asbestos insulation from ductwork SF 3000

0A6 Wrap and cut and remove insulated ductwork. SF 3000

0A7 Remove asbestos mastic from ductwork or pipe insulation SF 870

0A8 Remove asbestos from fittings and valves, up to 4" diameter pipe EA 69

0A9 Remove asbestos from fittings and valves, 6" to 8" diameter pipe, IPS EA 34

0A10 Remove asbestos from fittings and valves, 10" — 12" diameter pipe, IPS

EA 27

0A11 Bulk Asbestos Removal — Remove fireproofing from flat surface

SF 1380

0A12 Bulk Asbestos Removal — Remove fireproofing from irregular surface

SF 690

0A13

Bulk Asbestos Removal — Remove plaster ceiling, including suspension system, plaster & lathe SF 690

0A14 Remove Asbestos from Pipe by Glove Bag (pipe up to 3" IPS) LF 140

0A15 Remove Asbestos from Pipe by Glove Bag (pipe 3.5" to 8" diameter, IPS)

LF 90

0A16 Remove Asbestos from Fittings and Valves by Glove Bag (up to

8", IPS)

EA 9

0A17 Remove Asbestos pipe support blocks, bottom half of pipe at supports.

EA 9

OPTION YEAR 1

ASBESTOS ABATEMENT

MATERIALS/EQUIPMENT — UNIT PRICING

0A18 Remove Asbestos Cement Board SF 70

0A19* Disposal asbestos waste in certified landfill loads less than 5

CY

CY 44

0A20* Disposal asbestos waste in certified landfill loads greater than 5 CY

TON 10

0A21 Remove Asbestos from Pipe in containment, up to 4" diameter pipe, IPS

LF 140

0A22 Remove Asbestos from pipe in containment, 4" to 8" diameter pipe, IPS

LF 90

0A23 Remove Asbestos from pipe in containment, 10" to 12" diameter pipe/IPS

LF 70

0A24 Remove Asbestos from pipe in containment, 14" to 16" diameter pipe/IPS

LF 35

0A25 Remove/Replace Asbestos Flexible Duct Connection (up to 24"duct)

SF 300

0A26 Removal of fiberglass batt insulation up to 12" thick SF 70

0A27 Removal of up to 12" thick fiberglass blown-in insulation in attic.

SF 70

0A28

Install ANSI/OSHA approved identification labels, tags and/or signs where asbestos remains EA 70

0A29 Apply penetrating encapsulant on ceiling and other structural surfaces

SF 700

0A30 Seal exposed ends of asbestos pipe insulation. EA 35

0A31 Spray apply one (1) coat of penetrating encapsulant — Flat surface

SF 700

0A32 Spray apply one (1) coat of penetrating encapsulant — Pipes, beams, columns, tanks

SF 700

0A33 Remove of floor tiles or carpet and remove mastic with chemicals SF 3000

0A34 Remove floor tiles — each additional layer SF 3000

0A35 Remove of linoleum and remove mastic with chemicals SF 3000

0A36

Remove windows and perimeter sealant as asbestos & install temporary protection in opening with plywood and studs — Wrap, seal as asbestos and/or lead paint or both

SF of rough opng

0A37 Remove asbestos containing caulking exterior of building first floor or on scaffolding

LF 3000

0A38 Excavate and remove contaminated dirt, by hand — Crawl Space

CU. FT. 850

0A39

In a crawl space, remove debris, flatten contaminated earth, pour a fiber reinforced, 3" thick 3000 psi concrete slab, float finish. All equipment including concrete pump.

SF 2500

0A40 Contaminated Waste: Bag, Remove from work area. BAG 2500

0A41 Contaminated Waste Wrapped Items Remove from work area EA 1290

0A42 Excavate and remove contaminated dirt, by hand — Crawl Space

CU. FT. 690

0A43 Remove vinyl wall base & asbestos glue LF 470

0A44 Remove mastic by HEPA filtered bead blasting rather than chemicals

SF 3000

No. 0B Work Description Units Qty $/Unit Total

0B1 Abrasive Blasting flat, round, shaped SF 170

0B2 Chemical stripping larger areas not covered below SF 170

0B3 Chemical Stripping - paint from Window Sash SF 170

0B4 Chemical Stripping - paint from Window Sill LF 170

0B5 Scrape & Encapsulate - paint on Window Sash SF 170

0B6 Scrape & Encapsulate - paint on Window Sills LF 170

0B7 Scrape & Encapsulate - paint on masonry SF 170

0B8 Power Tool Cleaning SF 170 0B9 Encapsulation SF 170

0B10 Removal of material- Trim LF 70

* Line items that do not require time and one half have been identified via asterisks on the rate schedule.

Note to CONTRACTOR: Asbestos abatement in the medical center often occurs in the evenings and weekends to accommodate patients and staff. Identify a multiplier (if any) to be applied to base unit prices for work beyond normal hours (8 am. — 4:30 pm.).

LEAD CONTAINING PAINT ABATEMENT

MATERIALS/EQUIPMENT- UNIT PRICING

0B11 Removal of material- Drywall SF 140

0B12

Remove windows with lead containing paint & install temporary protection in opening with plywood and studs — Wrap, seal as containing lead paint

SF of rough opng

0B13 Removal of abandoned pipe or de-energized conduit > 4” dia LF 70

0B14 Removal of abandoned pipe or de-energized conduit < 4” dia LF 35

0B15 TCLP sampling of waste EA 9

0B16

Seal hazardous waste in DOT-standard 55 gal drums, store, transport, and disposal in a licensed landfill

DRUM 9

0B17 Loading for transport and disposal waste in a truck or dumpster CY 17

No. 0C Work Description Units Qty $/Unit Total

0C1 Removal of Material-Drywall on studs or furring SF 1400

0C2 Removal of Material-Carpet & glue SF 170

0C3 Removal of Material -Carpet Tile & glue SF 170

0C4 Removal of Material-VCT & glue

SF 480

0C5 Removal of Material-Linoleum & glue SF 480

0C6 Removal of Material-Ceramic Tile SF 35

0C7 Removal of Material - Plywood on floor or wall SF 350

0C8 Removal of Material- Contaminated Fiberglass Batt Insulation up to 6" thick

SF 350

0C9 Removal of Contaminated Fiberglass Insulation 7" up to 12" thick

SF 350

0C10 Removal of up to 12" thick fiberglass blown-in insulation in attic.

SF 70

0C11 Mold Remediation/Removal on Concrete Wall or Floor SF 340

0C12 Mold Remediation/Removal on Drywall SF 690

0C13 Multiplier for Off-Hours - Outside

8AM - 4:30PM 0

MOLD ABATEMENT MATERIALS/EQUIPMENT-

UNIT PRICING

No. 0D Work Description Units Qty $/Unit Total

0D1* Mobilization on projects. Work area isolation EA 2

0D2* Mobilization on projects. No work area isolation EA 1

0D3* Emergency Response EA 1 0D4* Work Plan EA 3

0D5 Elevated Work Surfaces in containment. Scaffolding (per SF floor area)

Per SF Floor Area 260

0D6 HEPA negative air machine (each) Per WEEK 87

0D7 Cleaning of Surfaces. Pre-cleaning, HEPA vacuum & wet wiping

SF 13800

0D8

Decontamination System. 2" x 4" @ 16", 5/8" plywood each side — 3 Stage Personal Decontamination Chamber with shower

EA 2

0D9

Decontamination System.

Disposable 3-stage decontamination system including shower

EA 2

0D10 Install and Remove Temporary Partition with 2" x 4" @ 16" studs and plastic sheeting

SF of Partition 350

0D11

Install and Remove Temporary 1Hr. Fire Rated Partition with 2" x 4" @ 16" studs & 5/8" drywall on each side, joints taped and fire caulking, one self closing locking door

SF of Partition 3500

0D12

Sealing and Protecting the Work Area on existing wall surfaces— Masking and sealing surfaces, each layer, 6-mil poly sheeting.

SF of Surface

ea. Layer 13800

0D13

Sealing and Protecting the Work Area on existing ceiling surfaces— Masking and sealing surfaces, each layer, 6-mil poly sheeting.

SF of Surface

ea. Layer 13800

0D14

Sealing and Protecting the Work Area — Protect carpeted area, 2 layers 6-mil poly on 3/4" plywood SF 1700

0D15 Containment Wall (5/8" plywood or drywall ea. side), 2' x 4" @ 16"

— 8 ft. high

SF of Partition 350

ITEMS COMMON TO ASBESTOS, LEAD, AND

MOLD ABATEMENT MATERIALS/EQUIPMENT-

UNIT PRICING

0D16 Containment Wall (5/8" plywood or drywall ea. side), 2' x 4" @ 16"

— 12 ft. high

SF of Partition 350

0D17 Containment Wall (5/8" plywood or drywall ea. side), 2' x 4" @ 16" —16 ft. high

SF of Partition 350

0D18*

Exterior (or interior) 1/2 in. x 48

in. x 96 in. Cellular White PVC Panel on studs or furring (intended for transite replacement). Exterior grade caulking all joints and seams.

SF 350

0D19* General non-HAZMAT waste haul and disposal charges - Loads greater than 5 CY

Per Ton 10

0D20* General waste non-HAZMAT haul and disposal charges - Loads less than 5 CY

Per CY 44

0D21 Truck and temporary storage of small quanties of hazardous waste in a secure location.

Per CY 44

0D22 Install new commercial carpet tile, 24 x 24 SY 170

0D23 Install new commercial carpet SY 170

0D24 Install new commercial floor tile, 12" x 12" SF 170

0D25 Install new 5/8" drywall over studs or furring (not incl.), tape and finish.

SF of D.W. 1380

0D26 Install new 3 1/2" metal or wood studs @ 16" o.c. for walls up to 10' high.

SF of Wall 1380

0D27 Painting, new, on drywall or masonry, 3 coats.

SF of Wall 1380

0D28 Patching drywall damaged in abatement or removing base, ready for Paint

SF of patch 170

0D29 Insulate F.G. w/ PVC Jacket fittings and valves, up to 4" diameter pipe, IPS

EA 70

0D30 Insulate F.G. w/ PVC Jacket fittings and valves, 6" to 8" diameter pipe, IPS

EA 34

0D31 Insulate F.G. w/ PVC Jacket fittings and valves, 10" — 12" diameter pipe, IPS

EA 27

0D32 Insulate 2" F.G. w/ PVC Jacket Pipe, up to 4" diameter pipe, IPS LF 140

0D33 Insulate 2" F.G. w/ PVC Jacket Pipe, 5" to 8" diameter pipe/Iron Pipe Size IPS

LF 86

0D34 Replacement Material- Fiberglass Batt Insulation up to 6" thick SF 345

0D35 Replacement Material Fiberglass Insulation 7" up to 12" thick SF 345

0D36 Replacement Material up to 12" thick fiberglass blown-in insulation in attic.

SF 70

0D37

New pipe support blocks, bottom half of pipe at supports, and new pipe insulation shields. Nominal pipe size 6".

EA 9

TOTALS

OPTION YEAR 1

File details come from the government source that posted it. Updated .