The document is a comprehensive Vet Center Exterior Signage Guide issued by the U.S. Department of Veterans Affairs (VA) Veterans Health Administration in April 2022, providing detailed specifications for exterior signage across various sign types. The guide establishes strict standards for sign design, color usage, and placement, including preferred applications like channel letters on raceways and secondary options such as lightbox, monument, pylon, and door decal signs. Specific requirements include using Pantone-specified colors (light blue 7461C, dark blue 647C, and red 1797C), maintaining precise logo proportions, and ensuring signage is legible from the main serving road while complying with local municipal codes.

The guide mandates that all exterior sign applications must strictly adhere to these standards without exception, with VA's Readjustment Counseling Service Communications Office requiring approval of design schematics before fabrication and installation. Signage must be implemented by the lessor, who shall provide all necessary equipment, materials, and labor. Key specifications include using pigmented or printed translucent vinyl on white acrylic faces, maintaining a minimum 3/8-inch white reveal around colored areas, and using white LED illumination where possible. The document also provides detailed instructions for door decal signage, including the requirement to display the Vet Center Call Center number (1-877-927-8387) and the slogan "Connection. Camaraderie. Community."

View the file

Other files

File Type Posted
RLP 36C24425R0051 Amendment 0003 ABOA Clarification and Revised Exhibit F.pdf PDF
Exhibit F Revised 1364.pdf PDF
RLP 36C24425R0051 Amendment 0002 Pre-Proposal Summary and Official Answers.pdf PDF
RLP 36C24425R0051 Amendment 0001 Pre-Proposal Meeting.pdf PDF
Attachment 1 Past Performance Questionnaire Sussex County Vet Center.pdf PDF
Exhibit Q Interior Signage Guide Sussex County Vet Center.pdf PDF
Exhibit K - Contract Submittal Schedule.pdf PDF
SLAT RLP Sussex County Vet Center - FINAL 03.14.2025.pdf PDF
Exhibit G Form 1217 Lessors Annual Cost Statement Nov. 2016.pdf PDF
Exhibit A SLAT Lease Sussex County Vet Center L100A FINAL 03.14.2025.pdf PDF
Exhibit D1 VA Provision Addendum Alternate Protest Procedure.pdf PDF
Exhibit T FAR 52.204-24 Representation Digital Nov. 2021.pdf PDF
Exhibit C VA Security Requirements FSL Level II Oct 2024.pdf PDF
Exhibit H Prelease FPLS Evaluation Form.pdf PDF
Exhibit E GSA Form 3517A General Clauses Simplified Oct. 2023.pdf PDF
Exhibit F Form 1364 Proposal to Lease Space Jan. 2023 AMENDED.pdf PDF
Exhibit I Security Unit Price List FSL II Oct 2024.xlsx XLSX spreadsheet
Exhibit D 3516A Solicitation Provisions Simplified Oct. 2023.pdf PDF
Exhibit B Agency Specific Requirements SussexCounty Vet Center.pdf PDF
Exhibit J Wage Determination REV 3-7-25.pdf PDF
Exhibit U Tenant-Improvements Cost-Summary TICS Table.xlsx XLSX spreadsheet
36C24425R0051.docx DOCX document
Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Vet Center External Signage Guide

APRIL 2022

Exhibit R 1 of 18

Lessor:____________ Government:____________

The U.S. Department of Veterans Affairs (VA) Veterans Health Administration (VHA) Readjustment Counseling Service (RCS) created this Vet Center Exterior Signage Guide to provide guidance on all exterior signage related to the Vet Center brand. This guide shall serve as the official directive and final authority for all Vet Center signage standards until a revised version is issued and released.

All exterior sign applications must comply with these standards without exception. Alteration of Vet Center logo colors or design is prohibited unless otherwise stated in the following documentation. All signs must be in accordance with the local code and landlord specifications.

NOTE: VA will approve all signage design schematics prior to fabrication and installation.

Variation shall not exist outside these design specifications without prior authorization. Sign vendor or lessor shall contact the Contracting Officers Representative (COR) for review and approval of any modifications through VA’s Readjustment Counseling Service Communications Office.

Purpose

Exhibit R 2 of 18

Purpose 1 Vet Center Exterior Signage Requirements 4 Exterior Signage: Preferred Application 6

Channel Letters on Raceway 6 Channel Letters on Raceway Specifications 7

Exterior Signage: Secondary Applications 8 Lightbox and Multi-Tenant Signs 8 Single Tenant Monument and Pylon Signs 10 Restrictive Tenant Panel Sign 12

No Building, Monument, or Pylon Signage Exterior Panel Sign 14

Door Decal Signage 16

Table of Contents

Vet Center Exterior Signage Guide

Exhibit R 3 of 18

1. Install time and design/specifications must be included in bid quote but be listed as separate line items.

2. This service order and installation shall be coordinated with Contracting Officers Representative (COR).

3. The installation shall occur and be completed Monday-Friday between the hours of 8:00 AM-4:30 PM.

4. Deliveries must be scheduled through the COR before installation.

5. Confirmation from vendor shall be sent via email to COR who will inspect that all products are installed 100%. Upon completion of inspection, the COR will email the Contracting Officer authorizing that products have been received complete and that payment can be released.

6. Any damage to the Vet Center facility incurred through the installation process must be repaired within 30 days at the vendor’s expense.

GENERAL REQUIREMENTS

Exhibit R 4 of 18

• Lessor shall provide samples for the VA to review and approve prior to fabrication.

• Lessor shall provide Vet Center logo Exterior Signage on the Building Exterior as well as Door Decal signage.

• Lessor shall provide Vet Center logo Exterior Signage on Marquee.

• Lessor shall provide Vet Center logo Exterior Signage, Monument sign.

• Lessor shall develop, provide, deliver, stage/move, and install the new exterior sign.

• Lessor shall provide all the equipment, cabling, labor, materials, and sign.

• Signage shall be legible from main serving road.

• Signage shall comply with local municipality’s codes and specifications.

SIZE: Maximum size in accordance with local building code.

EXTERIOR SIGNAGE REVIEW

Exhibit R 5 of 18

C h an n el L et te rs o n R ac ew ay

PREFERRED EXTERIOR SIGNAGE APPLICATION:

CHANNEL LETTERS ON A RACEWAY

Every effort shall be made to construct channel letters on a raceway, as this is the preferred application. In all cases where the channel letters on raceway sign is constructed for a building exterior, the exterior sign should be raceway mounted, with the raceway color matching the face of the building. The power connectors for the logo’s star and red stripe shall be remote mounted with external power links.

LIGHTING: In the case where illuminated signage is not permitted by ordinance, ½” thick stud-mounted acrylic letters shall be used.

Channel Letters on a Raceway Signs

Exhibit R 6 of 18

CHANNEL LETTERS ON A RACEWAY

COLOR SPECIFICATIONS FOR CHANNEL LETTERS ON A RACEWAY SIGN

Colors are to be pigmented Translucent Vinyl over White Acrylic Faces with a minimum of 3/8th of an inch white reveal around each colored area. Trim cap and returns shall be white. White LED Illumination. Raceway mounted channel letters with raceway to match building. Each letter should be one piece, with vinyl and white space used to simulate the stencil effect.

BUILD SPECIFICATIONS FOR CHANNEL LETTERS ON A RACEWAY SIGN

MATERIAL SPECIFICATONS FOR CHANNEL LETTERS ON A RACEWAY SIGN

STRIPE AND STAR

8” Deep Cans Remote Mounted wire to main text with connectors

White Trim Cap & White Returns

VET CENTER

5” Deep Cans

White LED Lamps

POWER

CONNECTOR:

Painted to match building facade

ATTACHMENTS:

All attachments to be appropriate to exterior wall construction

RACEWAY:

Raceway 3” x 8” painted to match building facade

Low Voltage Power Supply

Internal Power Connection

Typical Wall Construction

EXTERIOR WALLCHANNEL LETTERS

CHANNEL LETTER

FACES:

Channel letter faces should have a minimum 3/8th of an inch white reveal around the colored overlays.

RED- PANTONE 1797C

CMYK: 13 94 83 3

DARK BLUE- PANTONE 647C

CMYK: 91 63 20 4

LIGHT BLUE- PANTONE 7461C

CMYK: 96 42 6 0

NOTE: The black outline is for visual reference only - trim cap is to be white. Pigmented vinyl or printed translucent vinyl application shall be used. If using printed translucent vinyl applications, the vinyl should be printed with an image-white-image process to ensure color consistency and density when the sign is illuminated. The image should be printed in color, overprinted in white, and overprinted again in color to avoid appearance of color washout when illuminated.

Vet Center Exterior Signage Guide

Exhibit R 7 of 18

L ig h tb ox a n d

M u lt i-T en an t

SECONDARY EXTERIOR SIGNAGE APPLICATION:

LIGHTBOX AND MULTI-TENANT DESIGN

In the case where the preferred application of the channel letters on a raceway sign is not possible, the secondary application choice is a lightbox and multi-tenant design. Where a lightbox sign is the only choice available, the logo design shall appear as shown in the color specifications for lightbox and multi-tenant design.

LIGHTING: Determined by existing signage.

Lightbox and Multi-Tenant Design Signs

Exhibit R 8 of 18

LIGHTBOX AND MULTI-TENANT SIGN

COLOR SPECIFICATIONS FOR LIGHTBOX AND MULTI-TENANT SIGN

BUILD SPECIFICATIONS FOR LIGHTBOX AND MULTI-TENANT SIGN

Pigmented vinyl or printed translucent vinyl application shall be used. If printing the image is required, the colors must match the specifications shown. Sign shall match existing site signage. New polycarbonate or acrylic panels shall be used.

MATERIAL SPECIFICATONS FOR LIGHTBOX AND MULTI-TENANT SIGN

PREFERRED DESIGN - NEW SIGNS

Due to the restrictive nature of sign codes and available space, accomodations have been made to allow a slightly smaller clear space but not to exceed the height or width of the star at scale.

Logo maximized to fit allowable lightbox width.

Clear space around logo cannot exceed the height or width of the star at scale within the lightbox space.

ALLOWABLE EXCEPTIONS: Maximizing Available Space In the case where the logo design cannot expand symmetrically to the size of the lightbox, exceptions are allowed to maximize the logo design in either the height or the width of the lightbox space.

Logo maximized to fit allowable lightbox height.

RED- PANTONE 1797C

CMYK: 13 94 83 3

DARK BLUE- PANTONE 647C

CMYK: 91 63 20 4

LIGHT BLUE- PANTONE 7461C

CMYK: 96 42 6 0

NOTE: The black outline is for visual reference only - trim cap is to be white. Pigmented vinyl or printed translucent vinyl application shall be used. If using printed translucent vinyl applications, the vinyl should be printed with an image-white-image process to ensure color consistency and density when the sign is illuminated. The image should be printed in color, overprinted in white, and overprinted again in color to avoid appearance of color washout when illuminated.

Vet Center Exterior Signage Guide

Exhibit R 9 of 18

Si n gl e

T en an t

M on u m en t an d

P yl on

SECONDARY EXTERIOR SIGNAGE APPLICATION:

SINGLE TENANT MONUMENT AND PYLON SIGNS

In the case where the preferred application of the channel letters on a raceway sign is not possible, another secondary application choice is a single tenant monument or pylon sign design. The logo design shall appear as shown in the color specifications. If the sign face is wide and short, the vendor shall maximize the size of the logo leaving an appropriate amount of white space around the logo as indicated in the build specifications guidance.

LIGHTING: Determined by existing signage.

Single Tenant Monument and Pylon Signs

Exhibit R 10 of 18

SINGLE TENANT MONUMENT AND PYLON SIGN

COLOR SPECIFICATIONS FOR SINGLE TENANT MONUMENT AND PYLON SIGN

Pigmented vinyl or printed translucent vinyl application shall be used. If printing the image is required, the colors must match the specifications shown. Sign shall match existing site signage. New polycarbonate or acrylic panels shall be used.

BUILD SPECIFICATIONS FOR SINGLE TENANT MONUMENT AND PYLON SIGN

MATERIALS FOR SINGLE TENANT MONUMENT AND PYLON SIGN

RED- PANTONE 1797C

CMYK: 13 94 83 3

DARK BLUE- PANTONE 647C

CMYK: 91 63 20 4

LIGHT BLUE- PANTONE 7461C

CMYK: 96 42 6 0

PREFERRED DESIGN - NEW SIGNS

Due to the restrictive nature of sign codes and available space, accomodations have been made to allow a slightly smaller clear space but not to exceed the height or width of the star at scale.

Logo maximized to fit allowable lightbox width.

Clear space around logo cannot exceed the height or width of the star at scale within the lightbox space.

ALLOWABLE EXCEPTIONS: Maximizing Available Space In the case where the logo design cannot expand symmetrically to the size of the lightbox, exceptions are allowed to maximize the logo design in either the height or the width of the lightbox space.

Logo maximized to fit allowable lightbox height.

NOTE: The black outline is for visual reference only - trim cap is to be white. Pigmented vinyl or printed translucent vinyl application shall be used. If using printed translucent vinyl applications, the vinyl should be printed with an image-white-image process to ensure color consistency and density when the sign is illuminated. The image should be printed in color, overprinted in white, and overprinted again in color to avoid appearance of color washout when illuminated.

Vet Center Exterior Signage Guide

Exhibit R 11 of 18

R es tr ic ti ve

T en an t

P an el

RESTRICTIVE TENANT PANEL SIGNS

In the case where the preferred application of the channel letters on a raceway sign is not possible, a secondary application choice is a restrictive tenant panel sign. When there is nothing but a solid, non-illuminated panel to use (common in office complexes, with multi-tenant panels) the words “Vet Center” shall be used in the appropriate color and font for that sign. Wherever possible, the logo shall be shown. When the logo cannot be used, the words “Vet Center” shall be used.

LIGHTING: Determined by existing signage.

Restrictive Tenant Panel Signs

VET CENTER

Exhibit R 12 of 18

RESTRICTIVE TENANT PANEL SIGN

COLOR SPECIFICATIONS FOR RESTRICTIVE TENANT PANEL SIGN

BUILD SPECIFICATIONS FOR RESTRICTIVE TENANT PANEL SIGN

The materials should match the existing signage, and can range from cut vinyl lettering to routed/engraved tenant panels.

MATERIAL SPECIFICATIONS FOR RESTRICTIVE TENANT PANEL SIGN

RED- PANTONE 1797C

CMYK: 13 94 83 3

DARK BLUE- PANTONE 647C

CMYK: 91 63 20 4

LIGHT BLUE- PANTONE 7461C

CMYK: 96 42 6 0

NOTE: The black outline is for visual reference only - trim cap is to be white. Pigmented vinyl or printed translucent vinyl application shall be used. If using printed translucent vinyl applications, the vinyl should be printed with an image-white-image process to ensure color consistency and density when the sign is illuminated. The image should be printed in color, overprinted in white, and overprinted again in color to avoid appearance of color washout when illuminated.

PREFERRED DESIGN - NEW SIGNS

Due to the restrictive nature of sign codes and available space, accomodations have been made to allow a slightly smaller clear space but not to exceed the height or width of the star at scale. When possible, follow the guidelines for logo spacing within the restricitve tenant panel.

Logo maximized to fit allowable lightbox width.

Clear space around logo cannot exceed the height or width of the star at scale within the lightbox space.

ALLOWABLE EXCEPTIONS: Maximizing Available Space In the case where the logo design cannot expand symmetrically to the size of the lightbox, exceptions are allowed to maximize the logo design in either the height or the width of the lightbox space.

Logo maximized to fit allowable lightbox height.

Vet Center Exterior Signage Guide

Exhibit R 13 of 18

E tr an ce P an el

S ig

EXTERIOR POSTED PANEL SIGN

Where there is no ability to place a channel lettering on raceway sign, monument sign, or pylon sign, thus restricting you to a sign by the entrance door, an exterior posted panel sign shall be used. If space is not available by the entrance door, a non-illuminated post and panel sign shall be constructed outside of the building, near the main entrance. All exterior Vet Center signage within a facililty, i.e. medical building, must comply with regulations set forth by the Americans with Disabilities Act (ADA) and include braille, as required.

LIGHTING: Determined by signage placement.

Suite 1A

Exterior Posted Panel Sign - Entrance Door or Nearby

Exhibit R 14 of 18

EXTERIOR POSTED PANEL SIGN - ENTRANCE

DOOR OR NEARBY

COLOR SPECIFICATIONS FOR ENTRANCE PANEL SIGN

Pigmented vinyl or printed translucent vinyl application shall be used. If printing the image is required, the colors must match the specifications shown. Sign shall match existing site signage. New polycarbonate or acrylic panels shall be used.

MATERIAL SPECIFICATIONS FOR ENTRANCE PANEL SIGN

BUILD SPECIFICATIONS FOR ENTRANCE PANEL SIGN

ACCEPTABLE SIGN DESIGN

12”w x 8” h

A 2” d x 12” h x 36” w aluminum post and panel with internal 2” square posts is required. The sign base shall be no less than 24” above grade. (This is not to be confused with a directional sign.)

19” w x 6” h

36”

36”

12”

Suite 1A

RED- PANTONE 1797C

CMYK: 13 94 83 3

DARK BLUE- PANTONE 647C

CMYK: 91 63 20 4

LIGHT BLUE- PANTONE 7461C

CMYK: 96 42 6 0

NOTE: The black outline is for visual reference only - trim cap is to be white. Pigmented vinyl or printed translucent vinyl application shall be used. If using printed translucent vinyl applications, the vinyl should be printed with an image-white-image process to ensure color consistency and density when the sign is illuminated. The image should be printed in color, overprinted in white, and overprinted again in color to avoid appearance of color washout when illuminated.

Vet Center Exterior Signage Guide

Exhibit R 15 of 18

DOOR DECAL SIGNAGE

The Lessor shall provide signage on the main entrance door. The door decal shall be printed on a clear background. A white poster-like background for the door decal display is unacceptable. The Vet Center Call Center number shall be shown as the numeric 1-877-927-8387 only. Avoid use of the “WAR-VETS” phonewords.

A full-color Vet Center logo shall be used with an accompanying “Connection.

Camaraderie. Community.” slogan in white. Alterations to this brand shall not be made. If other building notices are needed, such as an automatic door symbol, spacing accomodations can be made.

Accompanying font: Zilla Slab preferred; Rockwell is an approved alternative.

Door Decal Signage

D oo r D ec al

S ig n ag e

NOTE: (Above left) Spacing accomodations for automatic door symbol may be made. (Below) The door decal shall be printed on a clear background. A white poster-like background or a white stroke around the lettering is unacceptable.

Exhibit R 16 of 18

DOOR DECAL SIGNAGE

COLOR SPECIFICATIONS FOR DOOR DECAL SIGNAGE

Digitally printed on clear vinyl application shall be used. The colors must match the color specifications of the logos.

BUILD SPECIFICATIONS FOR DOOR DECAL SIGNAGE

MATERIAL SPECIFICATIONS FOR DOOR DECAL SIGNAGE

[Vet Center Slogan Logo]

[Vet Center Name] Greatest Vet Center [Vet Center Address] 123 Lane, Greatest City, VA [Core Hours] Open Monday-Friday 8AM-4:30PM Ask about additional hours to meet your needs

[Vet Center Office Phone Number] (012) 345-6789

After Hours Vet Center Call Center

1-877-927-8387

Veterans Crisis Line Call 1-800-273-8255 and

Press 1 to receive confidential support 24 hours a day.

[VA Seal]

RED- PANTONE 1797C

CMYK: 13 94 83 3

DARK BLUE- PANTONE 647C

CMYK: 91 63 20 4

LIGHT BLUE- PANTONE 7461C

CMYK: 96 42 6 0

NOTE: The black background is for visual reference only. An additional white stroke around the letters of the Vet Center slogan logo should not be added for the purposes of the door decal. This differs from other designs used for prominent exterior signage.