36C24419B0008-0001004.pdf

PDF 79 KB Posted

Attached to
Upgrade Public Toilets First Floor Federal contract opportunity
Solicitation number
36C24419B0008
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 4

About this file

36C24419B0008 0001 Atch 6 Auto-Flush installation instructions.pdf

View the file

Other files for this federal contract opportunity

Other files attached to Upgrade Public Toilets First Floor, newest first.
File Type Posted
36C24419B0008-0001005.pdf PDF
36C24419B0008-0001000.docx DOCX document
36C24419B0008-0001001.pdf PDF
36C24419B0008-0001002.pdf PDF
36C24419B0008-0001003.pdf PDF
S02_Atch_2__Bid_Documents_Drawing_Set.pdf PDF
S02_Atch_3_UPTFF_-_Constructiion_Duration_-_Calendar_Days.pdf PDF
S02_Atch_1__Bid_Documents_Specification_02.pdf PDF
36C24419B0008.docx DOCX document
36C24419B0008_1.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GANG

SCREWS

SLOAN VALVE COMPANY

U.S.A.

(2

VA

C

IN

CO

NN

EC

T

TO

L

IS

TE

D C

LA

SS

S

OU

RC

E

(T O

VA

LV

E)

W

M

AX

CRITICAL DIMENSION

MUST BE WITHIN ± 1/8” (3 mm)

OPTIMA SYSTEMS

Electrical Box Rough-In Template for Sensor Operated Exposed Water Closet Flushometers.

WATER CLOSET FLUSHOMETER

TEMPLATE

WIRING DIAGRAM

Models: Royal,Regal/Sloan & Crown 110 ES-S /111 ES-S (DO NOT use this template for other Model ES-S Flushometers)

CUT ALONG DOTTED LINES

Note: A maximum of ten (10) Sensor Flushometer units can operate from one

(1) Sloan EL-154 transformer. Class II UL Listed, 48 VA (min.) at 24 VAC, plate mounted.

WIRING NOTES

Be certain power is OFF to prevent damage to electrical components.

Connect sensor to transformer and solenoid coil EXACTLY as shown in Wiring Diagram.

Connect the 24 volt source lead to terminal labeled “24 VAC IN” of new sensor.

Connect solenoid lead to terminal labeled “TO VALVE” of new sensor.

Connect remaining solenoid lead to remaining 24 volt source lead.

Connect override button parallel to the EL-1500-L sensor. Use 18 gauge wire between override button terminals and the connection of the EL-1500-L sensor.

This template will serve as a guide when Roughing-In the Electrical Boxes required for a Sloan OPTIMA Flushometer. If further assistance is needed contact your nearest Sloan Representative Office.

Refer to the OPTIMA Flushometer Installation Instructions for directions to install and operate the Valve.

120 VAC

24 VAC

GND

UNIT #1

UNIT #2

THRU #10

(IF USED)

IMPORTANT: Early Models of the Sensor were made with four (4) Wire Leads. When replacing a four (4) Wire EL-150-L Sensor with a three

(3) Wire EL-150-L Sensor the Black Lead replaces the Blue Lead, the Red Lead replaces the Yellow Lead and the White Lead combines and replaces the Brown & Red Leads.

SLOAN • 10500 SEYMOUR AVENUE • FRANKLIN PARK, IL 60131

Phone: 800.800.982.5839 • Fax: 1-847-671-4380 • sloanvalve.com

Copyright © 2015 Sloan Valve Company Template — Rev. 1 (10/15) Code No. 0816157

24 VAC COIL

24 VAC COIL

SOLENOID

GROUND

WIRE

SOLENOID

GROUND

WIRE

COIL WIRE

COIL WIRE

EL-1500-L SENSOR

EL-1500-L SENSOR

SENSOR

“TO VALVE”

CONNECTION

“24 VAC IN”

CONNECTION

CUT ALONG DOTTED LINES

4” X 4” X 2-1/2” DEEP

ELECTRICAL JUNCTION BOX

(102 mm X 102 mm X 63 mm)

WATER SUPPLY

1” (DN 25 mm) I.P.S.

C/L

OF

ELECTRICAL

BOX

SENSOR LOCATION AND POSITIONING

IS CRITICAL!

Failure to properly position the electrical boxes to the plumbing rough-in will result in improper installation and impair product performance. All tradesmen (plumbers, electricians, tile setters, etc.)

involved with the installation of this product must coordinate their work to assure proper product installation.

Note: When installing the valve with the EL-485-A positioning and support kit, refer to the instructions packaged with the

EL-485-A. DO NOT USE THIS PAPER TEMPLATE.

IMPORTANT!

DO NOT use this template for other Model

ES-S Flushometers.

TOP OF FIXTURE

HOW TO USE TEMPLATE

• Cut out Supply and Box openings (dotted lines).

• Place template over water supply rough-in.

• Align “C/L of Fixture” on template with actual Center Line of Fixture.

• Mount Electrical Box according to opening in template.

POSITION OF SENSOR BOX CAN BE

RAISED OR LOWERED 1” (25 mm) IF IN

CONFLICT WITH HANDICAP GRAB BARS

OVERRIDE BUTTON

2 ¾” (70 mm)

CUT ALONG DOTTED LINES

CUT ALONG DOTTED LINES

CUT ALONG DOTTED LINES

CUT ALONG DOTTED LINES CUT ALONG DOTTED LINES

CUT ALONG DOTTED LINES

IMPORTANT: MOUNT GANG SCREWS OF PLASTER

RING OR GANGBOX WITH SCREWS ON THE SIDES

19” (482 mm)

FROM TOP

OF FIXTURE

2-3/4” (70 mm) 4-3/4” (121 mm)

SLOAN ADJUSTABLE TAIL

ALLOWS ± 1/2” (13 mm) VARIATION

C/L

OF

FIXTURE

1-1/2” (38 mm)

CRITICAL DIMENSION MUST

BE WITHIN ± 1/8” (3 mm)

11-1/2” (292 mm)

FROM TOP

OF FIXTURE

2 ¼” (70 mm)

4 ¾” (121 mm)

19” (482 mm)

11½” (292 mm)

1½” (38 mm)

C/L OF

ELECTRICAL

BOX

File details come from the government source that posted it.