36C24419B0008-0001004.pdf
PDF 79 KB Posted
- Attached to
- Upgrade Public Toilets First Floor Federal contract opportunity
- Solicitation number
- 36C24419B0008
About this file
36C24419B0008 0001 Atch 6 Auto-Flush installation instructions.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C24419B0008-0001005.pdf | ||
| 36C24419B0008-0001000.docx | DOCX document | |
| 36C24419B0008-0001001.pdf | ||
| 36C24419B0008-0001002.pdf | ||
| 36C24419B0008-0001003.pdf | ||
| S02_Atch_2__Bid_Documents_Drawing_Set.pdf | ||
| S02_Atch_3_UPTFF_-_Constructiion_Duration_-_Calendar_Days.pdf | ||
| S02_Atch_1__Bid_Documents_Specification_02.pdf | ||
| 36C24419B0008.docx | DOCX document | |
| 36C24419B0008_1.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GANG
SCREWS
SLOAN VALVE COMPANY
U.S.A.
(2
VA
C
IN
CO
NN
EC
T
TO
L
IS
TE
D C
LA
SS
S
OU
RC
E
(T O
VA
LV
E)
W
M
AX
CRITICAL DIMENSION
MUST BE WITHIN ± 1/8” (3 mm)
OPTIMA SYSTEMS
Electrical Box Rough-In Template for Sensor Operated Exposed Water Closet Flushometers.
WATER CLOSET FLUSHOMETER
TEMPLATE
WIRING DIAGRAM
Models: Royal,Regal/Sloan & Crown 110 ES-S /111 ES-S (DO NOT use this template for other Model ES-S Flushometers)
CUT ALONG DOTTED LINES
Note: A maximum of ten (10) Sensor Flushometer units can operate from one
(1) Sloan EL-154 transformer. Class II UL Listed, 48 VA (min.) at 24 VAC, plate mounted.
WIRING NOTES
Be certain power is OFF to prevent damage to electrical components.
Connect sensor to transformer and solenoid coil EXACTLY as shown in Wiring Diagram.
Connect the 24 volt source lead to terminal labeled “24 VAC IN” of new sensor.
Connect solenoid lead to terminal labeled “TO VALVE” of new sensor.
Connect remaining solenoid lead to remaining 24 volt source lead.
Connect override button parallel to the EL-1500-L sensor. Use 18 gauge wire between override button terminals and the connection of the EL-1500-L sensor.
This template will serve as a guide when Roughing-In the Electrical Boxes required for a Sloan OPTIMA Flushometer. If further assistance is needed contact your nearest Sloan Representative Office.
Refer to the OPTIMA Flushometer Installation Instructions for directions to install and operate the Valve.
120 VAC
24 VAC
GND
UNIT #1
UNIT #2
THRU #10
(IF USED)
IMPORTANT: Early Models of the Sensor were made with four (4) Wire Leads. When replacing a four (4) Wire EL-150-L Sensor with a three
(3) Wire EL-150-L Sensor the Black Lead replaces the Blue Lead, the Red Lead replaces the Yellow Lead and the White Lead combines and replaces the Brown & Red Leads.
SLOAN • 10500 SEYMOUR AVENUE • FRANKLIN PARK, IL 60131
Phone: 800.800.982.5839 • Fax: 1-847-671-4380 • sloanvalve.com
Copyright © 2015 Sloan Valve Company Template — Rev. 1 (10/15) Code No. 0816157
24 VAC COIL
24 VAC COIL
SOLENOID
GROUND
WIRE
SOLENOID
GROUND
WIRE
COIL WIRE
COIL WIRE
EL-1500-L SENSOR
EL-1500-L SENSOR
SENSOR
“TO VALVE”
CONNECTION
“24 VAC IN”
CONNECTION
CUT ALONG DOTTED LINES
4” X 4” X 2-1/2” DEEP
ELECTRICAL JUNCTION BOX
(102 mm X 102 mm X 63 mm)
WATER SUPPLY
1” (DN 25 mm) I.P.S.
C/L
OF
ELECTRICAL
BOX
SENSOR LOCATION AND POSITIONING
IS CRITICAL!
Failure to properly position the electrical boxes to the plumbing rough-in will result in improper installation and impair product performance. All tradesmen (plumbers, electricians, tile setters, etc.)
involved with the installation of this product must coordinate their work to assure proper product installation.
Note: When installing the valve with the EL-485-A positioning and support kit, refer to the instructions packaged with the
EL-485-A. DO NOT USE THIS PAPER TEMPLATE.
IMPORTANT!
DO NOT use this template for other Model
ES-S Flushometers.
TOP OF FIXTURE
HOW TO USE TEMPLATE
• Cut out Supply and Box openings (dotted lines).
• Place template over water supply rough-in.
• Align “C/L of Fixture” on template with actual Center Line of Fixture.
• Mount Electrical Box according to opening in template.
POSITION OF SENSOR BOX CAN BE
RAISED OR LOWERED 1” (25 mm) IF IN
CONFLICT WITH HANDICAP GRAB BARS
OVERRIDE BUTTON
2 ¾” (70 mm)
CUT ALONG DOTTED LINES
CUT ALONG DOTTED LINES
CUT ALONG DOTTED LINES
CUT ALONG DOTTED LINES CUT ALONG DOTTED LINES
CUT ALONG DOTTED LINES
IMPORTANT: MOUNT GANG SCREWS OF PLASTER
RING OR GANGBOX WITH SCREWS ON THE SIDES
19” (482 mm)
FROM TOP
OF FIXTURE
2-3/4” (70 mm) 4-3/4” (121 mm)
SLOAN ADJUSTABLE TAIL
ALLOWS ± 1/2” (13 mm) VARIATION
C/L
OF
FIXTURE
1-1/2” (38 mm)
CRITICAL DIMENSION MUST
BE WITHIN ± 1/8” (3 mm)
11-1/2” (292 mm)
FROM TOP
OF FIXTURE
2 ¼” (70 mm)
4 ¾” (121 mm)
19” (482 mm)
11½” (292 mm)
1½” (38 mm)
C/L OF
ELECTRICAL
BOX