201703536_002.pdf

PDF 229 KB Posted

Attached to
N091--PROJECT # 528-18-110 Fuel Oil Tank Replacement BUFFALO VAMC
Solicitation number
36C24226B0057
Issued by

About this file

This is a laboratory test report from EMSL Analytical, Inc. documenting lead concentration analysis in paint chip samples collected from the VA Medical Center in Buffalo, New York. The analysis was conducted using Flame Atomic Absorption Spectroscopy (AAS) following EPA SW 846 3050B/7000B methodology, with samples collected on April 12, 2017, and analyzed on April 19, 2017. The report was received and processed on April 17, 2017, at 10:30 AM, with final results printed on April 20, 2017.

Two paint chip samples were analyzed: sample BUF-1-71B yielded a lead concentration of 0.27% by weight, while sample BUF-6-0DT-2 returned a result below the detection limit of 0.0080% by weight. The laboratory, located in Cinnaminson, New Jersey, maintains NELAP certifications in New Jersey (03036), New York (10872), and Pennsylvania (68-00367), as well as AIHA-LAP and A2LA accreditations. The analysis was authorized under EMSL Order 201703536 for customer VAMD30, with quality control data meeting recovery and precision requirements as confirmed by Phillip Worby, Lead Laboratory Manager. The reporting limit was established at 0.008% by weight based on minimum sample weight per the laboratory's standard operating procedures.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Client Sample Description ConcentrationLab ID Analyzed Lead

Collected

EMSL Analytical, Inc.

200 Route 130 North, Cinnaminson, NJ 08077 Phone/Fax: (856) 303-2500 / (856) 786-5974 http://www.EMSL.com cinnaminsonleadlab@emsl.com

Attn: Heidi Reisman VA Medical Center 3495 Bailey Ave.

Buffalo, NY 14215

Received: 04/17/17 10:30 AM

Ref Transaction Number 528-17-3-4890-0155

Fax: (716) 862-8810 Phone: (716) 862-8826

Project:

4/12/2017Collected:

Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*

201703536 CustomerID: VAMD30 CustomerPO: Ref Trans ProjectID:

EMSL Order:

201703536-0001BUF-1-71B 0.27 % wt4/19/20174/12/2017 201703536-0002BUF-6-0DT-2 <0.0080 % wt4/19/20174/12/2017

Phillip Worby, Lead Laboratory Manager or other approved signatory

Test Report ChmSnglePrm/nQC-7.32.3 Printed: 4/20/2017 10:05:18 AM

*Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.008 % wt based on the minimum sample weight per our SOP. Unless noted, results in this report are not blank corrected. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities. Samples received in good condition unless otherwise noted. "<" (less than) result signifies that the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. The QC data associated with the sample results included in this report meet the recovery and precision requirements unless specifically indicated otherwise.

Definitions of modifications are available upon request.

Samples analyzed by EMSL Analytical, Inc. Cinnaminson, NJ NELAP Certifications: NJ 03036, NY 10872, PA 68-00367, AIHA-LAP, LLC ELLAP 100194, A2LA 2845.01

Initial report from 04/20/2017 10:05:18 http://www.EMSL.com mailto:cinnaminsonleadlab@emsl.com