This document is an EMSL Analytical, Inc. Asbestos Analysis Test Report for a sample collected from the VA Buffalo Medical Center. The report details the analysis of black mastic samples from behind a radiator in an exterior wall, using Polarized Light Microscopy (PLM) via the NY State ELAP 198.6 Method. Specifically, Sample 1205-S01 was found to contain 6.8% Chrysotile asbestos, with 93.2% non-asbestos fibers, while Sample 1205-S02 was marked as a "Positive Stop (Not Analyzed)". The analysis was conducted on samples collected on 12/05/2023 and analyzed on 12/06/2023, with the report issued by EMSL Analytical, Inc. from their Depew, NY location.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EMSL Analytical, Inc.
490 Rowley Road Depew, NY 14043
Tel/Fax: (716) 651-0030 / (716) 651-0394 http://www.EMSL.com / buffalolab@emsl.com
EMSL Order: 142305650
Customer ID: TREV42
Customer PO: 528C30249
Project ID:
Attention: John Rogers Phone: (810) 986-0536
Trine Environmental Fax:
6678 Morningdale Drive Received Date: 12/05/2023 3:24 PM
Brighton, MI 48116 Analysis Date: 12/06/2023
Collected Date: 12/05/2023
Project: 36C24223P1440 VA Buffalo 9C
Test Report: Asbestos Analysis of Non-Friable Organically Bound Materials by PLM via the
NY State ELAP 198.6 Method
Sample ID Description Appearance
Matrix
Material
% Non-Asbestos
Fibers % Asbestos Types
1205-S01
142305650-0001
918C Black Mastic behind
Radiator Ext Wall
Black
Non-Fibrous
Homogeneous
93.2% None 6.8%
6.8%
Chrysotile
Total
Other
HA: HA 01
1205-S02
142305650-0002
914ack Mastic behind
Radiator Ext Wall
Positive Stop (Not Analyzed)
HA: HA 01
Auth Code:3121358809
Rhonda McGee, Laboratory Manager or other approved signatory
Analyst(s)
Hannah Parkes (1)
EMSL maintains liability limited to cost of analysis . Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations . The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Polarized Light Microscopy (PLM) is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative Transmission Electron Microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos containing. Inconclusive is defined as none detected or trace asbestos at 1% or less. All samples have been examined for the presence of vermiculite.This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government . Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Estimation of uncertainty is available on request.
Samples analyzed by EMSL Analytical, Inc. Depew, NY NYS ELAP 11606, NVLAP Lab Code 200056-0
ASB_PLMNYNOB_0016_0001 Printed 12/6/2023 1:43:05PM Page 1 of 1