This document is an attachment that provides technical specifications for a 600 kW Generac bi-fuel industrial generator set. The generator is EPA-compliant and designed for stationary emergency power applications. Key features include a digital control system, paralleling capability, and configurable options for the engine, fuel, electrical, and enclosure systems. The attachment is related to a federal contract opportunity issued by the Department of Veterans Affairs for the Upgrade Generac Generators project 526-20-107 at the James J. Peters DVA Medical Center in Bronx, NY. The solicitation number is 36C24224B0030.
View the file
Other files for this federal contract opportunity
Show all 19
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MB600 | 18.1L | 600 kW
INDUSTRIAL BI-FUEL GENERATOR SET
EPA Compliant Stationary Emergency
SP
EC
S
HE
ET
SP
EC
S
HE
ET
Image used for illustration purposes only
Standby Power Rating 600 kW, 750 kVA, 60 Hz
Prime Power Rating* 540 kW, 675 kVA, 60 Hz
*EPA Certified Prime ratings are not available in the US or its Territories
Codes and Standards Not all codes and standards apply to all configurations. Contact factory for details.
UL2200, UL6200, UL1236, UL142
CSA C22.2, ULC S601, B149
BS5514 and DIN 6271
SAE J1349
NFPA 37, 70, 99, 110
NEC700, 701, 702, 708
ISO 3046, 7637, 8528, 9001
NEMA ICS10, MG1, 250, ICS6, AB1
ANSI C62.41
TM
Powering Ahead Generac Bi-Fuel™ generators start on diesel fuel and add natural gas as load is applied until the unit runs primarily on natural gas. Generac’s Bi-Fuel generators are fully integrated solutions, not aftermarket conversions in the field. That means every component is specifically designed, engineered and factory-validated to work together. Generac Bi-Fuel generators have the added benefit of being EPA-compliant from the factory.
RISK MITIGATION VIA FUEL REDUNDANCY
Because nobody can predict how long a power outage will last, many diesel-fueled standby power systems are sized for extended running times.
Nevertheless, onsite diesel fuel supplies are limited, and infrastructure damage could make refueling difficult. Generac Bi-Fuel generators make the most of an onsite diesel fuel supply by running primarily on natural gas. That means less onsite diesel fuel is required and running times will be greatly extended compared to diesel-only solutions. And because the natural gas infrastructure tends not to be affected by the same conditions that lead to power outages, fuel reliability is improved.
LOWER TOTAL COST OF OWNERSHIP
Because natural gas costs less than diesel, fuel costs are significantly reduced over the long term. And since less onsite diesel fuel is required for long running times, installation, operational and maintenance costs are reduced.
SCALABILITY AS PART OF A MODULAR POWER SYSTEM
Generac Bi-Fuel generators can be configured as part of a Modular Power System (MPS)—connected via integrated paralleling with other Generac generators. This makes the system scalable, meaning there is no need to install more power than you need.
CODE COMPLIANCE
Generac Bi-Fuel generators meet the onsite fuel requirements for emergency systems as referenced in NEC700 and NFPA 110. Less onsite diesel fuel means easier permitting. And indoor fuel installations with capacity limits per NFPA or local codes become a viable option.
EPA Compliant Stationary Emergency
SP
EC
S
HE
ET
SP
EC
S
HE
ET
CONTROL SYSTEM
Digital G-200 Paralleling Panel-Touchscreen
Program Functions
• Programmable Crank Limiter
• 7-Day Programmable Exerciser
• Special Applications Programmable Logic Controller
• RS-232/485 Communications
• All Phase Sensing Digital Voltage Regulator
• 2-Wire Start Capability
• Date/Time Fault History (Event Log)
• Isochronous Governor Control
• Waterproof/Sealed Connectors
• Audible Alarms and Shutdowns
• Not in Auto (Flashing Light)
• Auto/Off/Manual Switch
• E-Stop (Red Mushroom-Type)
• NFPA110 Level I and II (Programmable)
• Customizable Alarms, Warnings, and Events
• Modbus® Protocol
• Predictive Maintenance Algorithm
• Sealed Boards
• Password Parameter Adjustment Protection
• Single Point Ground
• 16 Channel Remote Trending
• 0.2 msec High Speed Remote Trending
• Alarm Information Automatically Annunciated on the
Display
Full System Status Display
• Power Output (kW)
• Power Factor
• kW Hours, Total and Last Run
• Real/Reactive/Apparent Power
• All Phase AC Voltage
• All Phase Currents
• Oil Pressure
• Coolant Temperature
• Coolant Level
• Engine Speed
• Battery Voltage
• Frequency
Alarms and Warnings
• Oil Pressure
• Coolant Temperature
• Coolant Level
• Low Fuel Pressure
• Engine Overspeed
• Battery Voltage
• Alarms and Warnings Time and Date Stamped
• Snap Shots of Key Operation Parameters During
Alarms and Warnings
• Alarms and Warnings Spelled Out (No Alarm Codes)
ENGINE SYSTEM
• Oil Drain Extension
• Air Cleaner
• Level 1 Fan and Belt Guards (Open Set Only)
• Stainless Steel Flexible Exhaust Connection
• Critical Silencer (Enclosed Units Only)
• Factory Filled Oil and Coolant
FUEL SYSTEM
• Primary and Secondary Fuel Shutoff
• Primary and Secondary Fuel Filters
COOLING SYSTEM
• Closed Coolant Recovery System
• UV/Ozone Resistant Hoses
• Factory-Installed Radiator
• 50/50 Ethylene Glycol Antifreeze
ELECTRICAL SYSTEM
• Battery Charging Alternator
• Battery Cables
• Battery Tray
• Rubber-Booted Engine Electrical Connections
• Solenoid Activated Starter Motor
ALTERNATOR SYSTEM
• Class H Insulation Material
• 2/3 Pitch
• Skewed Stator
• Permanent Magnet Excitation
• Amortisseur Winding
• Sealed Bearing
• Full Load Capacity Alternator
GENERATOR SET
• Internal Genset Vibration Isolation
• Separation of Circuits - High/Low Voltage
• Separation of Circuits - Multiple Breakers
• Wrapped Exhaust Piping (Enclosed Units Only)
• Standard Factory Testing
• 2 Year Limited Warranty (Standby Rated Units)
• 1 Year Limited Warranty (Prime Rated Units)
• Silencer Mounted on the Discharge Hood
(Enclosed Units Only)
ENCLOSURE (If Selected)
• Rust-Proof Fasteners with Nylon Washers to Protect Finish
• High Performance Sound-Absorbing Material (Sound Attenuated Enclosure)
• Gasketed Doors
• Upward Facing Discharge Hoods (Radiator and Exhaust)
• Stainless Steel Lift Off Door Hinges
• Stainless Steel Lockable Handles
• RhinoCoat™ - Textured Polyester Powder Coat Paint
FUEL TANKS (If Selected)
• UL 142/ULC S-601
• Double Wall
• Vents
• Sloped Top
• Sloped Bottom
• Factory Pressure Tested (2 psi)
• Rupture Basin Alarm
• Fuel Level
• Check Valve in Supply and Return Lines
• RhinoCoat™ - Textured Polyester Powder Coat Paint
• Stainless Hardware
STANDARD FEATURES
PARALLELING CONTROLS
• Auto-Synchronization Process
• Isochronous Load Sharing
• Reverse Power Protection
• Maximum Power Protection
• Electrically Operated, Mechanically Held Paralleling
Switch
• Sync Check System
• Independent On Board Paralleling
• Shunt Trip and Auxiliary Contact
EPA Compliant Stationary Emergency
SP
EC
S
HE
ET
SP
EC
S
HE
ET
CONFIGURABLE OPTIONS
ENGINE SYSTEM
○ Air Filter Restriction Indicator
○ Radiator Stone Guard (Open Set Only)
○ Engine Coolant Heater
○ Level 1 Fan and and Belt Guards (Enclosed Units Only)
○ Oil Heater
○ Shipped Loose Critical Silencer (Open Set Only)
FUEL SYSTEM
○ NPT Flexible Fuel Line
ELECTRICAL SYSTEM
○ 10A UL Listed Battery Charger
○ Battery Warmer
ALTERNATOR SYSTEM
○ Alternator Upsizing
○ Anti-Condensation Heater
CIRCUIT BREAKER OPTIONS
○ Main Line Circuit Breaker
○ Electronic Trip Breakers
GENERATOR SET
○ Extended Factory Testing
○ IBC Seismic Certification
○ 12 Position Load Center
ENCLOSURE
○ Weather Protected Enclosure
○ Level 1 Sound Attenuated
○ Level 2 Sound Attenuated
○ Level 2 Sound Attenuated with Motorized Dampers
○ Steel Enclosure
○ Aluminum Enclosure
○ Up to 200 MPH Wind Load Rating (Contact Factory for Availability)
○ AC/DC Enclosure Lighting Kit
○ Enclosure Heater (with Motorized Dampers Only)
CONTROL SYSTEM
○ NFPA 110 Compliant 21-Light Remote Annunciator
○ Remote Relay Assembly (8 or 16)
○ Oil Temperature Indication and Alarm
○ Remote E-Stop (Break Glass-Type, Surface Mount)
○ Remote E-Stop (Red Mushroom-Type, Surface Mount)
○ Remote E-Stop (Red Mushroom-Type, Flush Mount)
○ 10A Engine Run Relay
○ Ground Fault Annunciator
○ Programmable Logic Full Auto Back-Up Control (PLS) for PM-SC
○ 100 dB Alarm Horn
○ 120V GFCI and 240V Outlets
○ Damper Alarm Contacts (with Motorized Dampers Only)
WARRANTY (Standby Gensets Only)
○ 2 Year Extended Limited Warranty
○ 5 Year Limited Warranty
○ 5 Year Extended Limited Warranty
○ 7 Year Extended Limited Warranty
○ 10 Year Extended Limited Warranty
ENGINEERED OPTIONS
ENGINE SYSTEM
○ Fluid Containment Pan
ALTERNATOR SYSTEM
○ 2nd Breaker Systems
CONTROL SYSTEM
○ Battery Disconnect Switch
GENERATOR SET
○ Special Testing
FUEL TANKS
○ Overfill Protection Valve
○ UL 2085 Tank
○ Stainless Steel Tank
○ Special Fuel Tanks (MIDEQ and FL DEP/DERM, etc)
○ Vent Extensions
EPA Compliant Stationary Emergency
SP
EC
S
HE
ET
SP
EC
S
HE
ET
General
Make Perkins
EPA Emissions Compliance Stationary Emergency
EPA Emissions Reference See Emission Data Sheet
Cylinder # 6
Type In-Line
Displacement - In3 (L) 1,106.36 (18.13)
Bore - in (mm) 5.71 (145)
Stroke - in (mm) 7.20 (183)
Compression Ratio 14.5:1
Intake Air Method Turbocharged/Aftercooled
Cylinder Head Type 4-Valve
Piston Type Aluminum
Crankshaft Type I-Beam Section
Engine Governing
Governor Electronic Isochronous
Frequency Regulation (Steady State) ±0.25%
Lubrication System
Oil Pump Type Gear
Oil Filter Type Full Flow
Crankcase Capacity - qt (L) 47.55 (45)
Cooling System
Cooling System Type Centrifugal
Fan Type Pusher
Fan Speed - RPM 1,439
Fan Diameter - in (mm) 38 (965)
Fuel System
Fuel Type Ultra Low Sulfur Diesel #2
Carburetor ASTM
Fuel Filtering (Microns) Primary 10 - Secondary 2
Fuel Inject Pump Make Electronic
Injector Type MEUI
Engine Type Pre-Combustion
Fuel Supply Line - in (mm) 0.5 (12.7) NPT
Fuel Return Line - in (mm) 0.5 (12.7) NPT
Required Natural Gas Pressure- psi (kPa) 1 (7)
Maximum Required Volume of Natural Gas Needed - cfm (m3/min)
50 (15)
Engine Electrical System
System Voltage 24 VDC
Battery Charger Alternator Standard
Battery Size See Battery Index 0161970SBY
Battery Voltage (2) - 12 VDC
Ground Polarity Negative
APPLICATION AND ENGINEERING DATA
ENGINE SPECIFICATIONS
ALTERNATOR SPECIFICATIONS
Standard Model K0792124Y23
Poles 4
Field Type Revolving
Insulation Class - Rotor H
Insulation Class - Stator H
Total Harmonic Distortion <3%
Telephone Interference Factor (TIF) <50
Standard Excitation Permanent Magnet
Bearings Single Sealed Cartridge
Coupling Direct via Flexible Disc
Prototype Short Circuit Test Yes
Voltage Regulator Type Digital
Number of Sensed Phases All
Regulation Accuracy (Steady State) ±0.25%
EPA Compliant Stationary Emergency
SP
EC
S
HE
ET
SP
EC
S
HE
ET
OPERATING DATA
** Refer to “Emissions Data Sheet” for maximum bHP for EPA and SCAQMD permitting purposes.
Deration – Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions.
Please contact a Generac Power Systems Industrial Dealer for additional details. All performance ratings in accordance with ISO3046, BS5514, ISO8528, and DIN6271 standards.
Standby - See Bulletin 0187500SSB Prime - See Bulletin 0187510SSB
POWER RATINGS
Standby
Three-Phase 277/480 VAC @0.8pf 600 kW Amps: 902
Three-Phase 346/600 VAC @0.8pf 600 kW Amps: 722
MOTOR STARTING CAPABILITIES (skVA) skVA vs. Voltage Dip
277/480 VAC 30%
K0792124Y23 2,250
K0832124Y23 2,800
FUEL CONSUMPTION RATES*
Diesel – gph (Lph)
Fuel Pump Lift - ft (m) Percent Load Standby
12 (3.7) 25% 18.4 (69.7)
50% 28.2 (88.7)
Total Fuel Pump Flow (Combustion + Return) gph (Lph) 75% 35.6 (124.8)
121 (457) 100% 41.4 (156.7)
* Fuel supply installation must accommodate fuel consumption rates at 100% load.
** Natural Gas substitution may vary based on the application and load conditions Please consult factory for additional details on fuel consumption
COOLING
Standby
Coolant Flow gpm (Lpm) 114.1 (432)
Coolant System Capacity gal (L) 15.5 (58.6)
Heat Rejection to Coolant BTU/hr (kW) 1,589,760 (466)
Inlet Air cfm (m3/min) 30,088 (852)
Maximum Operating Ambient Temperature °F (°C) 122 (50)
Maximum Operating Ambient Temperature (Before Derate) See Bulletin No. 0199270SSD
Maximum Additional Radiator Backpressure in H2O (kPa) 0.5 (0.12)
COMBUSTION AIR REQUIREMENTS
Standby
Flow at Rated Power - cfm (m3/min) 1,836 (52)
ENGINE EXHAUST
Standby Standby
Rated Engine Speed RPM 1,800 Exhaust Flow (Rated Output) cfm (m3/min) 5,085 (144)
Horsepower at Rated kW** hp 909 Maximum Allowable Backpressure inHg (kPa) 2.13 (6.9)
Piston Speed ft/min (m/min) 2,161 (658.7) Exhaust Temperature (Rated Output - Post Silencer) °F (°C) 1,155 (624)
BMEP psi (kPa) 361 (2,489)
EPA Compliant Stationary Emergency
SP
EC
S
HE
ET
SP
EC
S
HE
ET
DIMENSIONS AND WEIGHTS*
YOUR FACTORY RECOGNIZED GENERAC INDUSTRIAL DEALER
Specification characteristics may change without notice. Dimensions and weights are for preliminary purposes only. Please contact a Generac Power Systems Industrial Dealer for detailed installation drawings.
* All measurements are approximate and for estimation purposes only.
Part No 10000006997 Rev. E 10/19/2020
Generac Power Systems, Inc. | P.O.Box 8 | Waukesha, WI 53189 P: (262) 544-4811 ©2020 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice.
OPEN SET
Run Time
- Hours
Usable Capacity
- Gal (L)
L x W x H - in (mm) Weight - lbs (kg)
No Tank - 154.4 (3,923) x 71.0 (1,803) x 67.3 (1,709) 8,662 - 10,922 (3,929 - 4,954)
8 334 158.5 (4,025) x 71.0 (1,803) x 81.3 (2,065) 10,337 - 12,597 (4,689 - 5,714)
24 1,001 158.5 (4,025) x 71.0 (1,803) x 103.3 (2,623) 11,262 - 13,522 (5,108 - 6,133)
24 1,001 228.0 (5,791) x 71.0 (1,803) x 92.3 (2,344) 11,812 - 14,072 (5,358 - 6,383)
48 2,002 290.0 (7,366) x 71.0 (1,803) x 103.3 (2,623) 13,512 - 15,772 (6,129 - 7,154)
WEATHER PROTECTED ENCLOSURE
Run Time
- Hours
Usable Capacity
- Gal (L)
L x W x H - in (mm) Weight - lbs (kg) Enclosure Only
Steel Aluminum
No Tank - 207.4 (5,268) x 70.9 (1,800) x 79.9 (2,031) 12,672 (5,748) 11,585 (5,748)
8 334 207.4 (5,268) x 70.9 (1,800) x 93.9 (2,387) 14,347 (6,508) 13,260 (6,015)
24 1,001 207.4 (5,268) x 70.9 (1,800) x 115.9 (2,945) 15,272 (6,927) 14,185 (6,434)
24 1,001 228.0 (5,791) x 70.9 (1,800) x 104.9 (2,666) 15,822 (7,177) 14,735 (6,684)
48 2,002 290.0 (7,366) x 70.9 (1,800) x 115.9 (2,945) 17,522 (7,948) 16,435 (7,455)
LEVEL 1 SOUND ATTENUATED ENCLOSURE
Run Time
- Hours
Usable Capacity
- Gal (L)
L x W x H - in (mm) Weight - lbs (kg)
Steel Aluminum
No Tank - 247.5 (6,285) x 70.9 (1,800) x 80.0 (2,032)
3,472 (1,575) 1,812 (822)
8 334 247.5 (6,285) x 70.9 (1,800) x 94.0 (2,388)
24 1,001 247.5 (6,285) x 70.9 (1,800) x 116.0 (2,946)
24 1,001 247.5 (6,285) x 70.9 (1,800) x 105.0 (2,667)
48 2,002 290.0 (7,366) x 70.9 (1,800)x 116.0 (2,946)
LEVEL 2 SOUND ATTENUATED ENCLOSURE
Run Time
- Hours
Usable Capacity
- Gal (L)
L x W x H - in (mm) Weight - lbs (kg)
Steel Aluminum
No Tank - 207.4 (5,268) x 70.9 (1,800) x 114.1 (2,899)
8 334 207.4 (5,268) x 70.9 (1,800) x 128.1 (3,255)
24 1,001 207.4 (5,268) x 70.9 (1,800) x 150.1 (3,813) 3,809 (1,728) 1,958 (888)
24 1,001 228.0 (5,791) x 70.9 (1,800) x 139.1 (3,534)
48 2,002 290.0 (7,366) x 70.9 (1,800) x 150.1 (3,813)