528-19-104 ED DEPT VA BUFFALO Final Bid Submission X-Ray Drawings.pdf
PDF 21 MB Posted
- Solicitation number
- 36C24222B0041
About this file
This document provides details on a federal solicitation for site preparation and installation of x-ray equipment at the Emergency Department of the Veterans Affairs Medical Center in Buffalo, New York. The solicitation number is 36C24222B0041 and was issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 2. Proposed responses are due May 15th, 2022 and award is anticipated to be made on July 15th, 2022. The scope of work involves site preparation and installation of new x-ray equipment, with no further product or service requirements specified.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24222B0041 0006.docx | DOCX document | |
| 36C24222B0041 0005.docx | DOCX document | |
| S02 Wage Determination - Erie.pdf | ||
| 36C24222B0041 0004.docx | DOCX document | |
| 528-19-104 ED DEPT VA BUFFALO Final Bid Submission X-Ray Specifications (1).pdf | ||
| Sign-in sheet Walkthrough_2022_07_22_10_51_23_910.pdf | ||
| 528-19-104 RFI Log (bid)1.xlsx | XLSX spreadsheet | |
| 36C24222B0041 0003.docx | DOCX document | |
| 36C24222B0041 0002.docx | DOCX document | |
| P07 Wage Determination.pdf | ||
| 36C24222B0041 0001.docx | DOCX document | |
| 36C24222B0041_1.docx | DOCX document |
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
6/
/2
:3 9:
P
M
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
U.S. Department of Veterans Affairs
LIST OF DRAWINGS
PROJECT CONTACT DIRECTORY
LOCATION MAP
CONTRACT SPECIALIST CONTRACTING OFFICER REPRESENTATIVE (COR) ARCHITECT / MEP/FP & STRUCTURAL ENGINEERS acela architects + engineers, pc 2633 Moravian Avenue Allentown, PA 18103
Joseph L. Herman, AIA, NCARB, LEED AP Cell: (610) 417-7850 jherman@acela-ae.com
APPROVALS
PROJECT INFORMATION
ACELAJLH
C
U s e rs
\a k a n u s k y \D o c u m e n ts
\5 -1
-1
E
D D
E P
T V
A B
U F
F A
L O r2
X
-R a y C
M a k a n u s k y V
B N
S Y
.r v t
GI101
COVER SHEET
3/22/2022
BUFFALO VA MEDICAL CENTER
528-19-104X-RAY RENOVATION
BUFFALO VA MEDICAL CENTER
100% FINAL BID SUBMISSION
3495 BAILEY AVENUE BUFFALO, NY 14215
Thomas Heldwein Thomas.Heldwein@va.gov Cell: (716)349-3962
Tanya Baldwin Tanya.Baldwin@va.gov (716)862-7461 ext. 22443
X-RAY RENOVATION
PROJECT #: 528-19-104
Approved by Medical Center Director Approved by Director of Facility Management Service
Approved by Project COR Approved by Medical Director
Approved by Infection Control Approved by Safety Officer
Approved by Project CO
21-USDVA-04
VA WESTERN NEW YORK
HEALTHCARE SYSTEM,
BUFFALO VA CAMPUS
ARCHITECTURAL ELEMENTS
AE101 1ST FLOOR NEW WORK PLANS
GENERAL CONTRACT
GC101 1ST FLOOR ICRA CONTROL PLAN
GC102 LEAD SHIELDING DETAILS
GENERAL INFORMATION
GI101 COVER SHEET
GI102 GENERAL INFORMATION
GI201 1ST FLOOR LIFE SAFETY PLAN
ARCHITECTURAL DEMOLITION
AD101 1ST FLOOR DEMOLITION PLANS
INTERIOR FINISH ELEMENTS
AI101 1ST FLOOR FINISH PLANS
ARCHITECTURAL EQUIPMENT
AQ101 1ST FLOOR EQUIPMENT PLAN
AQ102 SIEMENS EQUIPMENT PLANS
AQ103 SIEMENS EQUIPMENT PLANS
AQ104 SIEMENS EQUIPMENT PLANS
AQ105 SIEMENS EQUIPMENT PLANS
AQ106 SIEMENS EQUIPMENT PLANS
FIRE PROTECTION
F101 1ST FLOOR FIRE PROTECTION DEMOLITION AND NEW WORK PLANS
MECHANICAL
M101 1ST FLOOR MECHANICAL DEMOLITION AND NEW WORK PLAN
ELECTRICAL
E001 ELECTRICAL ABBREVIATIONS, NOTES AND LEGENDS
E101 1ST FLOOR POWER DEMOLITION AND NEW WORK PLAN
E201 1ST FLOOR LIGHTING DEMOLITION AND NEW WORK PLAN
E301 ELECTRICAL SINGLE-LINE DIAGRAM AND DETAILS
HAZARDOUS ABATEMENT
HA101 1ST FLOOR ABATEMENT PLAN
STRUCTURAL
SF101 STRUCTURAL FRAMING PLANS, SECTIONS, AND DETAILS
Revisions: Date: NY LIC. NO.:
043141
CENTER LINE
DETAIL INDICATOR
DIMENSION LINE
DRAWING BLOCK TITLE, TYPICAL
BUILDING SECTION INDICATOR
TYPICAL DETAIL INDICATOR
FURNITURE, FIXTURE, & EQUIPMENT INDICATOR
EXISTING ROOM TAG - ROOM NAME AND NUMBER
EXISTING COLUMN TAG
ARCHITECTURAL KEYNOTE TAG
WALL OR PARTITION TYPE
FIRE EXTINGUISHER CABINET
CORNER GUARD
NORTH ARROW
CG
FEC
DETAIL NUMBER
SHEET WHERE
DRAWN
XX-XX
1"
XX-XX
CL
XX-XX
x'-x" SPOT ELEVATION
1 REVISION
REVISION CLOUD
BREAK LINE
DD ROOM TAG - ROOM NAME AND NUMBER
X
View Name 1/8" = 1'-0"
Room name
Room name
NEW DOOR / OPENING TAG
ELEVATION INDICATOR
EXISTING DOOR OPENING TAG
E###
N
P N
X REFLECTED CEILING KEYNOTE TAG
Room name
150 SF
LIFE SAFETY ROOM TAG - ROOM NAME, NUMBER AND AREA
X# INTERIOR SIGNAGE TAG
# WINDOW TAG
X RESTROOM ACCESSORY TAG
WOOD
WOOD FINISH
ALUMINUM
STEEL
EARTH
GYPSUM - PLASTER
MASONRY - CONCRETE BLOCK
RIGID INSULATION
BATT INSULATION
PLYWOOD
CONCRETE
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE REMOVED
& AND
@ AT
C CENTERLINE
# NUMBER
AB ANCHOR BOLT
ABV ABOVE
ACT ACOUSTIC CEILING TILE
AD AREA DRAIN
ADA AMERICANS WITH
DISABILITIES ACT
ADJ ADJUSTABLE
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
AIA AMERICAN INSTITUTE OF
ARCHITECTS
ALUM ALUMINUM
ALT ALTERNATE
AP ACCESS PANEL
APPROX APPROXIMATE
ARCH ARCHITECTURAL
AUTO AUTOMATIC
AVG AVERAGE
BD BOARD
BLDG BUILDING
BLK BLOCK
BM BEAM
BOT BOTTOM
BRG BEARING
BEL BELOW
BR BUMPER RAIL
BRK BRICK
CAB CABINET
CB CATCH BASIN
CEM CEMENT
CCT CUBICLE CURTAIN TRACK
CG CORNER GUARD
CI CAST IRON
CIP CAST IN PLACE
CJ CONTROL JOINT
CT CERAMIC TILE
CLG CEILING
CL CLOSET
COL COLUMN
CONC CONCRETE
CONF CONFERENCE
CONT CONTINUOUS
CPT CARPET
CU CUBIC
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIM DIMENSION
DISP DISPENSER
DN DOWN
DO DOOR OPENING
DOZ DOZEN
DP DAMPPROOFING
DR DOOR
DWG DRAWING
DWGS DRAWINGS
DWR DRAWER
E EAST
EA EXHAUST AIR, EACH
EL ELEVATION
ELEV ELEVATION
ELEC ELECTRICAL
EMER EMERGENCY
ENCL ENCLOSURE
ENGR ENGINEER
EP ELECTRICAL PANELBOARD
EQ EQUAL
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EWS EYE WASH STATION
EXP EXPANSION
EJ EXPANSION JOINT
EXIST EXISTING
EXT EXTERIOR
FA FIRE ALARM
FB FACE BRICK
FD FLOOR DRAIN
FDC FIRE DEPARTMENT
CONNECTION
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER
CABINET
FF FINISH FACE
FHC FIRE HOSE CABINET
FIN FINISH
FLR FLOOR
FLUOR FLUORESCENT
FO __ FACE OF __
FOC FACE OF CONCRETE
FOS FACE OF STUD
FOW FACE OF WALL
FPRF FIREPROOF(ING)
FR FIRE RATING, FRAME
FRMG FRAMING
FS FULL SIZE
FT FOOT OR FEET
FTG FOOTING
FUR FURRING
FUT FUTURE
GC GENERAL CONTRACTOR
GA GAUGE
GAL GALLON
GALV GALVANIZED
GALV STL GALVANIZED STEEL
GB GRAB BAR
GC GENERAL CONTRACTOR
GD GUARD
GL GLASS
GND GROUND
GR GRADE
GWB GYPSUM WALLBOARD
GYP BD GYPSUM WALLBOARD
HB HOSE BIBB
HC HOLLOW CORE
HD HEAD
HDWR HARDWARE
HDWD HARDWOOD
HT HEIGHT
HNDRL HANDRAIL
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HMF HOLLOW METAL FRAME
HR HANDRAIL
HO HOLD OPEN
HORIZ HORIZONTAL
HP HIGH POINT
HR HOUR
HVAC HEATING, VENTILATION, AIR
CONDITIONING
IBC INTERNATIONAL BUILDING CODE
ID IDENTIFICATION, INSIDE
DIAMETER / DIMENSION
IN INCH
INCL INCLUDE(D)
INSUL INSULATION
INT INTERIOR
INV INVERT
JAN JANITOR
JST JOIST
JT JOINT
KP KICK PLATE
KO KNOCKOUT
L LENGTH
LAB LABORATORY
LAM LAMINATE
LAV LAVATORY
LBS POUND
LED LIGHT EMITTING DIODE
LF LINEAR FEET
LH LEFT HAND
LIN LINEAR
LIQ LIQUID
LKR LOCKER
LG LONG
LL LEAD LINED
LLV LONG LEG VERTICAL
LP LOW POINT
LRG LARGE
LT LIGHT
LT WT LIGHTWEIGHT
LVR LOUVER
MATL MATERIAL
MAS MASONRY
MAX MAXIMUM
MECH MECHANICAL
MTL METAL
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MP MOP PLATE
MTD MOUNTED
N NORTH
NA NOT APPLICABLE
NEC NATIONAL ELECTRICAL CODE
NEG NEGATIVE
NFC NATIONAL FIRE CODE
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER / DIMENSION
OFF OFFICE
OH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OH OVERHEAD
OZ OUNCE
PAV PAVING
PC PRECAST CONCRETE
PL PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLYWD PLYWOOD
PLBG PLUMBING
PMF PREMOLDED FILLER
PR PAIR
PT POINT
PTN PARTITION
QT QUARRY TILE
R RADIUS, RISER
RA RETURN AIR
RAD RADIUS
RB RESILIENT BASE, RUBBER
BASE
RD ROOF DRAIN
RL ROOF LEADER
REF REFERENCE
REFR REFRIGERATOR
REQ'D REQUIRED
REV REVISION
RFI REQUEST FOR
INFORMATION
RFP REQUEST FOR PROPOSAL
RH RIGHT HAND
RM ROOM
RO ROUGH OPENING
S SOUTH
SA SUPPLY AIR
SAN SANITARY
SC SOLID CORE
SCHED SCHEDULE
SECT SECTION
SH SPRINKLER HEAD
SHT SHEET
SIM SIMILAR
SM SMOKE
SPEC SPECIFICATION
SPKR SPEAKER
SQ SQUARE
STA STATION
STD STANDARD
STO STORAGE
STL STEEL
SS STAINLESS STEEL
STOR STORAGE
STRUCT STRUCTURAL
SUSP SUSPENDED
SYM SYMMETRICAL
SYS SYSTEM
T TREAD
TEL TELEPHONE
TEMP TEMPERED
T&G TONGUE AND GROOVE
THK THICK
TOC TOP OF CONCRETE
TOP TOP OF PAVEMENT
TOS TOP OF STEEL
TOW TOP OF WALL
TV TELEVISION
TYP TYPICAL
UNFIN UNFINISHED
UON UNLESS OTHERWISE
NOTED
VB BAPOR BARRIER
VERT VERTICAL
VCT VINYL COMPOSITION TILE
VIF VERIFY IN FIELD
VTR VET THRU ROOF
W WEST
W/ WITH
WD WOOD
W/O WITHOUT
WP WATERPROOF
WT WEIGHT
WWF WELDED WIRE FRAME
NOTE: ALL ABBREVIATIONS SHOWN MAY NOT
BE USED ON THIS PROJECT. CERTAIN
COMMON ABBREVIATIONS MAY NOT BE
SHOWN.
1. ALL DIMENSIONS OF NEW PARTITIONS/BARRIERS SHALL BE TAKEN TO FACE OF STUD. DIMENSIONS TO EXISTING WORK SHALL BE TAKEN TO
FACE OF FINISH SURFACE
2. DO NOT SCALE DRAWINGS. DRAWINGS ARE CONCEPTUAL PLANS
3. THE WORK OF THE CONTRACTOR SHALL INCLUDE ALL LABOR AND MATERIALS FOR ALL TRADES CONCERNED FOR COMPLETING THE PROJECT
IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS
4. THE CONTRACTOR SHALL PROCURE, COMPLETE AND APPLY FOR ALL PERMITS AS REQUIRED TO CONSTRUCT THE PROJECT
5. THE CONTRACTOR SHALL BE FAMILIAR WITH THE CONTRACT DOCUMENTS. THE CONTRACTOR MUST ALSO VISIT THE SITE TO BE ACQUAINTED
WITH THE CONDITIONS AFFECTING THE WORK
6. WORKMANSHIP. ALL WORK TO BE FIRST RATE, HIGH QUALITY, AND ACCOMPLISHED IN A WORKMANLIKE MANNER BY SKILLED CRAFTSMEN
USING ACCEPTED PRACTICES AND METHODS APPROPRIATE TO THE TRADE INVOLVED
7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DAILY CLEANING UP OF THE WORK AREA. THE AREA SHALL BE CLEANED EACH DAY AND TRASH SHALL BE DISPOSED OF AT THE END OF EACH DAY. AT THE END OF THE PROJECT, THE CONTRACTOR SHALL CLEAN THE WORK AREA THOROUGHLY. CLEANING IS TO BE CONFIRMED BY THE COR AND / OR THE INFECTION CONTROL NURSE
8. ALL WORK SHALL BE GUARANTEED FOR ONE YEAR FROM THE TIME OF ACCEPTANCE BY THE OWNER UNLESS OTHERWISE NOTED IN THE
SPECIFICATIONS
9. ALL PLUMBING WORK SHALL CONFORM TO THE ADOPTED EDITION OF THE INTERNATIONAL PLUMBING CODE. INSTALL ALL WATER, WASTE AND VENT PIPING IN ACCORDANCE WITH ALL APPLICABLE CODES. REVIEW DRAWINGS AND PROVIDE ALL WORK FOR A COMPLETE AND OPERABLE SYSTEM, INCLUDING ALL INCIDENTALS, REQUIRED BY CODE AGENCIES AND LOCAL GOVERNING BODIES. CODES INCLUDE, BUT ARE NOT
LIMITED TO:
VA PLUMBING DESIGN GUIDE - 2021
10. PRIOR TO START OF CONSTRUCTION, CONTRACTOR SHALL VERIFY ALL BUILDING CONDITIONS, COORDINATE ALL DIMENSIONS IN FIELD AND
VERIFY ALL LOCATIONS OF UTILITIES IN THE FIELD
11. ALL HEATING, VENTILATING AND AIR CONDITIONING WORK SHALL CONFORM TO THE ADOPTED EDITION OF THE INTERNATIONAL MECHANICAL AND ENERGY CODES (AS APPLICABLE), STATE CODES, AND ANY REQUIREMENTS OF THE LOCAL AUTHORITIES HAVING JURISDICTION.
CODES INCLUDE, BUT ARE NOT LIMITED TO:
NFPA 101 - 2021
NFPA 70 - 2020
NFPA 90A - 2021
NFPA 99 - 2021
NFPA 101 - 2021
VA HVAC DESIGN GUIDE - 2021
13. THE COMPLETE ELECTRICAL SYSTEM AND INSTALLATION SHALL COMPLY AND CONFORM TO ALL ADOPTED CODES, REGULATIONS OF THE NATIONAL ELECTRICAL CODE AS WELL AS TO ALL STATE AND LOCAL LAWS, ORDINANCES AND CODES. CODES INCLUDE, BUT ARE NOT
LIMITED TO:
NFPA 70 - 2021
NFPA 101 - 2021
VA ELECTRICAL DESIGN GUIDE - 2019
VA ELECTRICAL DESIGN MANUAL FOR REPLACEMENT HOSPITALS, CLINICAL ADDITIONS, ENERGY CENTERS, AND LABORATORY
BUILDINGS - 2015
VA LIGHTING DESIGN MANUAL - 2022
VA RADIOLOGY DESIGN MANUAL - 2008
VA PHYSICAL SECURITY DESIGN MANUAL FOR LIFE SAFETY PROTECTED FACILITIES - 2021
14. THE COMPLETE FIRE PROTECTION SYSTEM AND INSTALLATION SHALL COMPLY AND CONFORM TO ALL ADOPTED CODES, REGULATIONS OF THE NATIONAL FIRE PROTECTION CODE AS WELL AS TO ALL STATE AND LOCAL LAWS, ORDINANCES AND CODES. CODES INCLUDE, BUT ARE NOT
LIMITED TO:
NFPA 101 - 2021
NFPA 13 - 2022
NFPA 72 - 2022
VA FIRE PROTECTION DESIGN GUIDE - 2021
1. SPACES AROUND THE PROJECT AREAS WILL BE OCCUPIED DURING PERFORMANCE OF WORK. IMMEDIATE AREAS OF ALTERATIONS WILL BE VACATED. ALL CONTRACTOR WORK WILL BE PERFORMED DURING NORMAL DAYTIME WORKING HOURS UNLESS INDICATED. ALL TEMPORARY SYSTEM SHUTDOWNS WILL OCCUR DURING 2ND SHIFT OR WEEKENDS AND COORDINATED AND APPROVED BY THE PROJECT COR. LONG TERM
LOCK-OUT / TAG-OUT WILL BE DONE DURING NORMAL WORKING HOURS
2. BEFORE STARTING WORK WITHIN AN OCCUPIED AREA, THE CONTRACTOR WILL BE RESPONSIBLE TO SET-UP TEMPORARY/PERMANENT CONSTRUCTION/ICRA BARRIERS WITH ANTEROOM AND MAINTAIN NEGATIVE AIR PRESSURE. ALL TEMPORARY CONSTRUCTION BARRIERS OUTSIDE THE INDICATED CONSTRUCTION PHASE AREA WILL BE REMOVED AT THE CONCLUSION OF THE WORK SHIFT. THE CONTRACTOR WILL BE RESPONSIBLE TO CLEAN AND PREPARE THE AREA TO BE OCCUPIED BY MEDICAL CENTER STAFF AND PATIENTS. CLEANING IS TO BE
CONFIRMED BY COR AND / OR THE INFECTION CONTROL NURSE
3. DIMENSIONS SUPERSEDE DRAWINGS. DO NOT SCALE PLANS. DIMENSIONS ARE TO THE FACE OF EXISTING MATERIALS UNLESS OTHERWISE NOTED. DIMENSIONS AND ELEVATIONS SHALL BE VERIFIED AT THE SITE BEFORE PROCEEDING WITH THE WORK. NOTIFY THE ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, AND MATERIALS REQUIRED FOR THE CONTRACTED WORK. REPORT ALL DISCREPANCIES TO ARCHITECT PRIOR TO FABRICATIONS AND ERECTION
4. IT IS SOLELY THE CONTRACTOR'S RESPONSIBILITY TO FOLLOW ALL APPLICABLE SAFETY CODES AND REGULATIONS DURING ALL PHASES OF CONSTRUCTION. ALL CONSTRUCTION WORK SHALL BE PERFORMED IN CONTRACTOR'S RESPONSIBILITY TO DETERMINE CONSTRUCTION PROCEDURES AND SEQUENCE AND TO INSURE THE SAFETY OF THE BUILDING AND ITS COMPONENT PARTS DURING CONSTRUCTION SHALL PROVIDE ADEQUATE SHORING AND BRACING DURING DEMOLITION AND CONSTRUCTION TO SUPPORT LOADS. SUCH MATERIAL SHALL BE REMOVED AT THE COMPLETION OF WORK AND SHALL REMAIN THE CONTRACTOR'S PROPERTY AFTER THE COMPLETION OF THE PROJECT
5. DO NOT CUT AND PATCH STRUCTURAL ELEMENTS IN A MANNER THAT WOULD REDUCE THEIR LOAD CARRYING CAPACITY OR LOAD-DEFLECTION RATIO. LOCATIONAL RESTRICTIONS ON ACHRONING TO STRUCTURAL MEMBERS ARE AS FOLLOWS:
A. ALL STRUCTURAL (HORIZONTAL AND VERTICAL) BEAMS ARE ENCASED IN CONCRETE
B. DAMAGE TO CONCRETE AROUND STRUCTURAL BEAMS IS TO BE REPORTED TO THE COR FOR REPAIR C. ATTACHMENTS ARE TO BE MADE TO THE FLOOR DECK, NOT TO THE BOTTOM OR SIDES OF BEAMS
D. NO FLOOR BORING CAN BE DONE WITHIN 6" OF THE CONCRETE BEAM SURROUNDS
E. DURING DEMOLITION, ANY EXISTING ATTACHMENTS SHOULD BE CUT FLUSH AND LEFT IN PLACE, MINIMIZING ANY CHANCE OF
DAMAGE TO CONCRETE ENCASEMENT
6. WHERE EXISTING CONSTRUCTION, EQUIPMENT, ETC. IS REQUIRED TO BE REMOVED, RESTORE EXPOSED FINISHES OF CUT AND PATCHED AREAS AND EXTEND FINISH RESTORATION INTO ADJOINING CONSTRUCTION IN A MANNER THAT WILL ELIMINATE EVIDENCE OF PATCHING AND REFINISHING. CUT EXISTING CONSTRUCTION USING METHODS LEAST LIKELY TO DAMAGE ELEMENTS TO BE RETAINED OR ADJOINING CONSTRUCTION. WHERE INDICATED TO REMOVE FINISHES, REMOVE SO TOTALLY, FROM PLANE TO PLANE, TREAT REMAINING SUBSURFACE TO
RECEIVE NEW FINISHES DESIGNATED
7. WHERE EXISTING CONSTRUCTION, EQUIPMENT, ETC. SHOWN TO BE RELOCATED SHALL BE COORDINATED BY THE CONTRACTOR WITH THE VA PRIOR TO START OF WORK IN EACH AREA. THE VA WILL REMOVE ALL ITEMS OF SALVAGEABLE VALUE, INCLUDING BUT NOT LIMITED TO DOORS, HARDWARE, MOVEABLE EQUIPMENT NOT ALREADY DESIGNATED FOR REINSTALLATION/REUSE, PRIOR TO CONTRACTOR COMMENCING WORK
8. WHERE EXISTING PARTITIONS HAVE BEEN REMOVED OR NEW SERVICES PENETRATE EXISTING SURFACES, THE OPENINGS SHALL BE PATCHED
TO MATCH THE EXISTING ADJACENT SURFACES FINISH, TEXTURE AND SHEEN
9. IN GENERAL, WHEREVER SERVICES ARE REMOVED, THE OPENINGS SHALL BE PATCHED TO MATCH THE EXISTING ADJACENT SURFACES FINISH TEXTURE AND SHEEN. WHERE REMOVAL OF EXISTING CONSTRUCTION, PIPING, DUCTWORK AND OTHER ITEMS CREATES OPENINGS IN THE WALLS, FLOORS OR CEILINGS, PATCH OPENINGS IMMEDIATELY WITH THE SAME MATERIALS AS ADJACENT CONSTRUCTION. MAINTAIN THE REQUIRED FIRE RATING. SEE MEP DRAWINGS FOR ADDITIONAL INFORMATION. FILL IN ALL EXISTING OPENINGS THAT ARE NOT TO REMAIN, UNLESS OTHERWISE NOTED. FINISH TO MATCH FINISH OF ADJACENT SURFACE
10. WHERE CODED NOTE DESIGNATIONS ARE SHOWN AS "TYP" OR "TYPICAL" IT IS INTENDED THAT THE NOTE GENERALLY REFERS TO ALL SIMILAR
ITEMS OR SURFACES
11. A HAZARDOUS MATERIALS SURVEY WAS CONDUCTED BY THE ARCHITECT OF RECORD. A HAZARDOUS MATERIALS SURVEY WAS SUPPLIED TO THE VA. THE RESULTS OF THE SAMPLES TAKEN ARE INCLUDED WITHIN THE CONSTRUCTION DOCUMENTS. IT IS THE CONTRACTORS RESPONSIBILITY TO TAKE PROTECTIVE MEASURES FOR ITS WORKERS PRIOR TO THE BEGINNING OF ANY RENOVATION OR DEMOLITION WORK.
IF ANY OTHER SUSPECT MATERIALS ARE NOTED, THE CONTRACTOR IS TO REPORT THEM TO THE COR AND ARCHITECT OF RECORD PRIOR TO
START OF WORK
12. AFTER COMPLETION OF DEMOLITION, SCHEDULE A WALK-THROUGH WITH THE COR AND ARCHITECT FOR REVIEW OF EXISTING CONDITIONS
13. PATCH AND FIRE STOP EXISTING ABANDONED PENETRATIONS THROUGH THE CONCRETE FLOORS AND WALLS
14. UNLESS OTHERWISE NOTED, ANY REMOVAL OF HVAC, PLUMBING OR ELECTRICAL IS TO BE 'BACK TO SOURCE' AND THE DISTANCE / LOCATION
MAY NOT BE TO SCALE ON THE DRAWINGS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
ACELAJLH
C U s e rs \a k a n u s k y \D o c u m e n ts
\5
-1
-1
E D
D E
P T
V
A B
U F
F A
L O r2
X
-R a y C
M a k a n u s k y V
B N
S Y
.r v t
/1
/2
:4
:3
A
M
GI102
GENERAL INFORMATION
3/22/2022
BUFFALO VA MEDICAL CENTER
528-19-104X-RAY RENOVATION100% FINAL BID SUBMISSION
PARTIALLY SPRINKLERED
21-USDVA-04
ARCHITECTURAL SYMBOLS MATERIAL LEGENDARCHITECTURAL ABBREVIATIONS
GENERAL NOTES - NEW CONSTRUCTION
GENERAL NOTES - GENERAL CONDITIONS
PET / CT
HOT LAB
INJECTION
CORRIDOR
CONTROL
ROOM
OFFICE OFFICE
OFFICE
EXAM EXAM
EXAM
EXAM
EXAM
PHARMACY
TELE HEALTH
101-E 102-E
EQUIP.
ALCOVE
CORRIDOR
WAITING
141D
144-E139-E138-E 143-E
CORRIDOR
137-E
136-E135-E
132-E
134-E
133-E
132-E1
131-E130-E129-E
146D-1
100E-18
126-E127-E128-E 101-A
125-E 124-E
123-E
100E-17
100A-5
104-A
100A-4
101A-1
102-1
100A-1
100-A
148D-1
147D-1149-D
154-D153-D152-D151-D
146-A146A-1
101-5
WAITING AREA
101-A
RECEPTION
103-A
RECEPTION
102-A NURSE'S
AREA
106-A
TRIAGE
101-A
TRIAGE
102-A
FAX/COPY
108-A
MEN'S
ROOM
110-A
WOMEN'S
ROOM
109-A
LAV.
108-A1
PHARMACY
CONSULT #2
107-A
ELEC.
113E-1
NURSES
STATION
UTILITY
LOBBY
100A-2
101-4
OFFICE
141-A
PHARMACY
CONSULT #1
140-A
138-A
136-A
137-A
100A-9
135-A
134-A
133-A
132-A
131-A 130-A
129-A
128-A
127-A
126-A
125-A
124-A
123-A
122-A 121-A 120-A 119-A 118-A 117-A 116-A
100A-8
CORRIDOR
#24
101-3
101-1
101-2135-B
101-D
100A-3
106-3 106-2
105-1
106-1
120-1
128 122 124 125
126130
114113112
110 117 118
136-B
103-2
110-2
110-1
103-1
138C-3
138C-2
138-C
139-C
100C-1
115-B
101-C 100C-4
100-C
102-C
103-C
104-C
105-C
106-C
107C-6
107C-7107-C 107C-8
107C-1 111C-5
111C-11
11C-7
111C-1111C-8
100C-4
110-C110C-1
100C-2
111C-2
111C-3
111C-6
111C-10 100C-5
111C-4
112C-1
112-C
100C-6
107C-4
107C-5
107C-2
107C-3
111C-9
113C-2
113C-1 113-C 114-C 116-C
138C-1 137-C
136-C
135-C
134-C
133-C
132-C
131-C
130-C
129-C
128-C
126-C
125-C
124-C
123-C
100C-3
122-C
120-C
EXISTING AREA
EXISTING AREA
EXISTING AREA
EXISTING AREA
CORRIDOR
.2"/OCC
CODE MIN:
PROVIDED:
44"
108"
1"
NOT INCLUDED IN THIS CONTRACT
NOT INCLUDED IN THIS CONTRACT
NOT INCLUDED IN THIS CONTRACT
NOT INCLUDED IN THIS CONTRACT
ELEV. ELEV. ELEV. ELEV. ELEV.
ELEV.ELEV.ELEV.ELEV.ELEV.
ELEV.
ELEV.
STAIR NO.6
326 SF
X-RAY
104D
54 SF
X-RAY
CONTROL ROOM
104D-1
TREATMENT #1
128D TREATMENT #2
129D
TREATMENT #3
130D TREATMENT #4
131D
TREATMENT #5
132D
STAIR
#6
STAFF
RESTROOM
126D
LOUNGE /
CONFERENCE
127D1
OBSERVATION #9
124D
CLEAN UTILITY
122D
NOURISH
108D
FAST-TRACK EXAM
109D
FAST-TRACK EXAM
110D
FAST-TRACK EXAM
111D
STAIR
#15
OBSERVATION
112D
OBSERVATION
113D
SOCIAL WORK
114D
DIRECTOR
OFFICE
115D
CORRIDOR
INTERN OFFICE
117D
STORAGE
118D
SOILED UTILITY
120D
RESTROOM
121D
CORRIDOR
NURSE'S STATION
127D
TRIAGE
106D
AMBULANCE BAY
DECON STORAGE
ISOLATION
STORAGE
133D1
RESTROOM
134D
PSYCH.
HOLDING
SOILED
UTILITY
137D
TRAUMA
138D
WAITING
139D
REGISTRATION
140D
DOOR
.2"/OCC
CODE MIN:
PROVIDED:
32"
32"
1"
CORRIDOR
.2"/OCC
CODE MIN:
PROVIDED:
44"
96"
1"
DOOR
.2"/OCC
CODE MIN:
PROVIDED:
32"
40"
27"
E60
E60
E
E
E90
E90 E90
E90
E
E
E90
E
E90
E
90STAIR
#11
E90
E
E90
E
STAIR
#13
STAIR
#12
E90
E
E90
E
E90
E
E90
E
STAIR
#10
STAIR
#9 E90
E90
E90
E90
STAIR
#14
E90 E90
E90 E90
E90
E90
E
E
STAIR
#1
E90
E90
E90
E90
E90
E90
STAIR
#5
E90
E90
E90
E90
STAIR
#8
E90
E90
E
E
STAIR
#7
E90
E90
E
E
STAIR
#4
STAIR
#3
STAIR
#2
E90
E90
E90
E90
E
E
E90
E90
E
E
147D
146D
145D
ELECTRICAL
135E-1
E90
E
E
E90
E90E90 E90
E90
E90
E90
E
E90
E90
E90 E90
E90
E
E90
E90
E90
E
ESM
ESM
E S
M
E S
M
E S
M
WING 'A'
WING 'D'
WING 'B'
WING 'C'
E S
M
ESM
ESM
ESM
TO EXIT C = 204'
EXIT A
EXIT B
EXIT C
EXIT D
EXIT E
EXIT F
C O
M M
O N P
A
TH
0'
TO EXIT D = 135'
GENERAL NOTES
A. PARTITIONS SHALL BE TYPE A1 UNLESS NOTED OTHERWISE
B. REFER TO SPECIFICATIONS AND PARTITION TYPE SCHEDULE FOR ADDITIONAL NOTES
C. NEW PARTITIONS ARE DIMENSIONED TO FACE OF METAL STUD OR MASONRY UNLESS
NOTED OTHERWISE
D. EXISTING PARTITIONS ARE DIMENSIONED TO FINISH FACE UNLESS NOTED OTHERWISE
FIRE RATING LEGEND
SYMBOL
(NUMBER SHOWS OPENING RATING)
BARRIER OPENING RATING
EXISTINGEXISTING
NOTE: FOR SCHEDULED OPENINGS WHERE SMOKE AND FIRE SEPARATIONS
COINCIDE,THE MORE STRINGENT FIRE RATING SHALL APPLY
FIRE EXTINGUISHER
E60E60
E90E90
EXIT LIGHT SIGNAGE
INDICATES COMMON PATH OF TRAVEL TO
POINT OF DECISION
INDICATES PATH OF TRAVEL TO POINT OF EXIT
(FROM COMMON PATH OF TRAVEL)
EXIT CAPACITIES LEGEND
DOORS
DOOR
.2"/OCC
CODE MIN:
PROVIDED:
32"
WIDTH PER OCCUPANT (2021 NFPA 101 TABLE 7.3.3.1)
OCCUPANTS (AREA/OCC. LOAD FACTOR)
MIN WIDTH (0.2" X OCC.)
CODE MIN (2021 NFPA 101 7.2.1.2.3.2)
CLEARANCE PROVIDED
CLEARANCE SHOWN W/ DOOR OPEN 90° BETWEEN STOP & OPEN DOOR FACE
CORRIDORS
WIDTH PER OCCUPANT (2021 NFPA TABLE 7.3.3.1)
OCCUPANTS (AREA/OCC. LOAD FACTOR)
MIN WIDTH (0.2" X OCC.)
CODE MIN (2021 NFPA 39.2.3.2)
CLEARANCE PROVIDED
CLEARANCE SHOWN BETWEEN FACE OF WALLS
STAIRS
WIDTH PER OCCUPANT (2021 NFPA TABLE 7.3.3.1)
OCCUPANTS (AREA/OCC. LOAD FACTOR)
MIN WIDTH (0.3" X OCC.)
CODE MIN (7.2.2.2.1.2)
CLEARANCE PROVIDED
* 2021 NFPA TABLE 7.2.2.2.1.1(b) EXISTING STAIRS
CORRIDOR
.2"/OCC
CODE MIN:
PROVIDED:
44"
STAIR
.3"/OCC
CODE MIN:
PROVIDED:
36" *
TRAVEL DISTANCE LIMITS
OCCUPANCY DISTANCE
COMMON PATH OF TRAVEL (2021 NFPA 21.2.5.2) 100'
DEAD END (2021 NFPA 21.2.5.3) 20'
TRAVEL DISTANCE LIMIT (2021 NFPA 21.2.6.2.1) 300'
* TRAVEL DISTANCES ARE FOR SPRINKLERED BUILDINGS
B
B
B
(2021 NFPA 101, TABLE 7.3.1.2 OCCUPANT LOAD FACTOR)
OCCUPANT LOAD FACTORS
SPACE FUNCTION SF/OCC
ASSEMBLY 15 NET
BUSINESS 150 GROSS
STORAGE 500 GROSS
DESIGN CODE
2021 NFPA 101 LIFE SAFETY CODE
CHAPTER 6: CLASSIFICATION OF OCCUPANCY AND HAZARD OF CONTENTS
6.1.6 AMBULATORY HEALTH CARE (EXISTING), CHAPTER 21
CHAPTER 21: EXISTING AMBULATORY HEALTHCARE OCCUPANCIES
OCCUPANCY SEPARATIONS (6.1.14.4; TABLE 6.1.14.4.1)
(EXISTING)
FIRE SUPPRESSION
PARTIALLY SPRINKLERED (EXISTING)
CONSTRUCTION TYPE
NFPA 101 2021 TABLE (20.1.6.1)
FIRE RESISTANCE RATINGS
COLUMN/BEAMS/GIRDERS
INTERIOR NON-BEARING WALLS (20.1.6.4)
MEANS OF EGRESS CAPACITY
AREA OF WORK SF/PERSON OCC. LOAD
GROSS AREA = 380 S.F. (EXISTING)
HEALTHCARE = 380 S.F. / 150 = 2.53 = 3
TOTAL OCCUPANCY LOAD = 3
THE DISTANCE FROM EXITS MAY BE A MINIMUM OF ONE-THIRD THE DIAGONAL DISTANCE
BUILDING SIZE
TOTAL BLDG. AREA: (EXISTING)
SIZE OF EACH ROOM IN PROPOSED WORK
FIRST FLOOR:
X-RAY & CONTROL ROOM 380 SF (EXISTING)
BUILDING HEIGHT
EXISTING BUILDING HEIGHT (BUILDING 1) = 11 STORIES ABOVE GRADE
EXIT ENCLOSURES/PASSAGEWAYS (7.1.3.2.1)
(EXISTING)
SHAFT ENCLOSURES (8.6.5)
(EXISTING)
EXIT ACCESS CORRIDORS (20.3.6.1)
(EXISTING)
CORRIDOR WIDTH (20.2.3.2)
(EXISTING)
DEAD END CORRIDORS (20.2.5.3)
(EXISTING)
SMOKE COMPARTMENTS (20.3.7.2)
(EXISTING)
SMOKE BARRIERS (20.3.7.6; 8.5)
(EXISTING)
HAZARDOUS AREA PROTECTION (20.3.2; 8.7.1.1)
(EXISTING)
20.2.6.2.1 TRAVEL DISTANCES
150' MAXIMUM
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
ACELAJLH
C U s e rs \a k a n u s k y \D o c u m e n ts
\5
-1
-1
E D
D E
P T
V
A B
U F
F A
L O r2
X
-R a y C
M a k a n u s k y V
B N
S Y
.r v t
/1
/2
:4
:4
A
M
GI201
1ST FLOOR LIFE SAFETY PLAN
3/22/2022
BUFFALO VA MEDICAL CENTER
528-19-104X-RAY RENOVATION100% FINAL BID SUBMISSION
PARTIALLY SPRINKLERED
21-USDVA-04
1/16" = 1'-0"1
FIRST FLOOR LIFE SAFETY PLAN
LIFE SAFETY CODE INFORMATION
PRECAUTIONS DURING CONSTRUCTION
1. EXECUTE WORK BY METHODS TO MINIMIZE RAISING DUST FROM CONSTRUCTION OPERATIONS
2. IMMEDIATELY REPLACE A CEILING TILE DISPLACED FOR VISUAL INSPECTION
3. PROVIDE ACTIVE MEANS TO PREVENT AIRBORNE DUST FROM DISPERSING INTO ATMOSPHERE
4. WATER MIST WORK SURFACES TO CONTROL DUST WHILE CUTTING DRY WALL FOR BARRIERS
5. SEAL UNUSED DOORS WITH DUCT TAPE IN THE CONSTRUCTION AREA
6. BLOCK OFF AND SEAL AIR VENTS IN THE CONSTRUCTION AREA
7. PLACE DUST MAT AT ENTRANCE AND EXIT OF WORK AREA
8. REMOVE OR ISOLATE HVAC SYSTEM IN AREA WHERE WORK IS BEING DONE TO PREVENT
CONTAMINATION OF DUCT SYSTEM
9. REMOVE CONSTRUCTION WASTE DAILY
10. PROVIDE TEMPORARY 1 HR. FIRE BARRIER PARTITIONS AS INDICATED AND SEAL UNUSED DOORS AT PERIMETER OF THE WORK AREA WITH PAINTER'S TAPE TO SEAL AREA FROM NON-WORK AREA BEFORE
CONSTRUCTION BEGINS
11. MAINTAIN NEGATIVE AIR PRESSURE WITHIN WORK SITE UTILIZING HEPA FILTER EQUIPPED AIR FILTRATION UNITS. COORDINATE LOCATION OF WINDOW AND ABOVE FLOOR PENETRATIONS WITH COR.
SPACE SHALL BE CONTINUOUSLY MONITORED BY MANOMETER. BALL IN THE WALL IS NOT ACCEPTABLE.
PATCH FLOOR PENETRATION AND REPLACE WINDOW GLAZING AFTER CONSTRUCTION AS REQUIRED
TO MATCH EXISTING
12. CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN TIGHTLY COVERED CONTAINERS OR BY COVERING IN PLASTIC AND SEALING WITH DUCT TAPE. REMOVE WASTE DAILY EITHER AFTER 5 PM AND
BEFORE 7 AM
13. USE ROUTE AGREED UPON BY THE ICRA TEAM AND COR FOR TRANSPORT OF TRANSPORT CONTAINERS
THROUGH THE FACILITY
14. SEAL HOLES, PIPES, CONDUITS, AND PUNCTURES AIRTIGHT AND/OR FIRE SEAL AS REQUIRED
15. CONSTRUCT AN AIRTIGHT ONE-HOUR RATED ANTEROOM AND REQUIRE ALL PERSONNEL TO PASS THROUGH THIS ROOM SO THEY CAN BE VACUUMED USING HEPA VACUUM CLEANER BEFORE LEAVING WORK SITE; OR WEAR PAPER COVERALLS THAT ARE REMOVED EACH TIME THEY LEAVE THE WORK SITE
16. ALL PERSONNEL ENTERING WORK SITE ARE REQUIRED TO WEAR SHOE COVERS. SHOE COVERS MUST
BE CHANGED EACH TIME THE WORKER EXITS THE WORK AREA THROUGH THE ANTEROOM
17. WORK OUTSIDE THE PRIMARY WORK AREA (AREA OF CONTAINMENT) WILL BE PERFORMED WITHIN A FIRE-RATED PLASTIC ENCLOSURE WITH NEGATIVE AIR HEPA FILTER SYSTEM TO CONTROL DUST.
ENCLOSURE TO BE CONSTRUCTED AND REMOVED DAILY AS REQUIRED BY THE COR. CONTRACTOR TO
SANITIZE WORK AREA PRIOR TO REMOVING PLASTIC CONTAINMENT AREA
GC101
A
WAITING
139D
REGISTRATION
140D
WAITING
141D
CORRIDOR
TRIAGE
106D
CORRIDOR
145-D
C
LEA
R
5'-0"
TD1
T1
EXISTING WALL OR
CONSTRUCTION BARRIER
EXISTING OR
ICRA DOOR
PROVIDE STICKY WALK-OFF MAT
(TYP. EACH SIDE OF DOOR)
PN
N
GENERAL AREA OF WORK
EXISTING IT CLOSET 138-E
EXISTING ELECTRICAL
PANEL 'BPH-1'
(BASEMENT)
LINE OF FINISHED FLOOR, SEE ROOM FINISH
SCHEDULE FOR FLOOR & BASE TYPE
FACE OF EXISTING WALL
3 5/8" METAL STUDS @ 16" O.C., TYPICAL
(1) LAYER 5/8" TYPE 'X' GYPSUM
BOARD BOTH SIDES
SECTION
PLAN
T1
/8
1-HR RATED
FIRE CAULK IN ACCORDANCE WITH UL 419
ASSEMBLY: UL-U419
STC: 48
NOTE: ANY PENETRATIONS THROUGH PARTITION ARE TO BE FIRE CAULKED
TEMPORARY CONSTRUCTION BARRIER
CONTINUOUS METAL STUD BOTTOM TRACK
SET IN CONTINUOUS BEAD OF SEALANT.
CONTINUOUS 3 1/2" SOUND
ATTENUATION BATTS AS SCHEDULE
CONTINUOUS METAL HORIZONTAL BRIDGING
CHANNEL @ MID HEIGHT, TYPICAL
FIRE CAULK IN ACCORDANCE WITH UL 419
METAL STUD FRAMING W/ 5/8" TYPE 'X'
GYPSUM BOARD, ONE SIDE
TYPE 'X' GYPSUM BOARD BOTH SIDES
RUBBER BASE. SEE FINISH SCHEDULE
BOTH SIDES
LINE OF CEILING SYSTEM, SEE ROOM
FINISH SCHEDULE FOR TYPE & HEIGHT
GLAZING PANEL REMOVAL
EXISTING EXTERIOR WALL CONSTRUCTION TO REMAIN
EXISTING EXTERIOR GLAZING PANEL TO BE
REMOVED FROM EXISTING WINDOW SYSTEM
PRIOR TO START OF ABATEMENT. GC TO
STORE GLAZING PANEL IN A SAFE LOCATION
UNTIL WORK IS COMPLETE AND REPLACE TO
IT'S EXISTING CONDITION. IF DAMAGED, GC
WILL REPLACE TO MATCH EXISTING
EXISTING ALUMINUM FRAME TO
REMAIN
HEPA EXHAUST
EXISTING WALL CONSTRUCTION TO
REMAIN
PROVIDE HEPA FILTRATION EXHAUST
DUCTING THROUGH NEW TEMPORARY
PLYWOOD PANEL
EXISTING ALUMINUM FRAME TO
REMAIN
PROVIDE 3/4" FIRE TREATED PLYWOOD
PANEL WITHIN EXISTING ALUMINUM FRAME
NOTE:
1. GENERAL CONTRACTOR TO LOCATE
PER QUANTITIES REQUIRED.
PROVIDE DUCT SEALING TAPE AROUND
PENETRATION (TYPICAL)
EXTERIORINTERIOR
EXTERIOR
INTERIOR
(NEGATIVE SPACE)
PORTION OF EXISTING LEAD LINED
INTERIOR PARTITION IS TO BE
REMOVED AS REQUIRED TO ALLOW
FOR TEMPORARY DUCTING
PENETRATION. PREP OPENING FOR
LEAD LINING REPAIR WHEN COMPLETE
STANDARD HM FRAME FOR
DRYWALL
PERIMETER CAULK BOTH
SIDES
CERAMIC TILE FINISH
WHERE REQUIRED
WIDTH
METAL STUD
DRYWALL, THICKNESS SINGLE
OR DOUBLE AS REQUIRED
DOUBLE STUDS BACK TO BACK
JAMB ANCHORS
J1 H1
DOOR TYPE NOTES:
1. ALL 'B' LABELED DOORS WILL HAVE A 90 MINUTE RATING.
2. ALL 'C' LABELED DOORS WILL HAVE A 45 MINUTE RATING.
TYPE 'F'
TYPE 1
(HM IN GWB)
H
W
T Y
P
J1
H1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
ACELAJLH
C U s e rs \a k a n u s k y \D o c u m e n ts
\5
-1
-1
E D
D E
P T
V
A B
U F
F A
L O r2
X
-R a y C
M a k a n u s k y V
B N
S Y
.r v t
/1
/2
:4
:3
A
M
GC101
1ST FLOOR ICRA CONTROL PLAN
3/22/2022
BUFFALO VA MEDICAL CENTER
528-19-104X-RAY RENOVATION100% FINAL BID SUBMISSION
PARTIALLY SPRINKLERED
21-USDVA-04
ICRA CONTROL POLICY
1/4" = 1'-0"1
1ST FLOOR - ICRA PARTITION PLAN
3/4" = 1'-0"A
STICKY WALK-OFF MAT DETAIL
FIRST FLOOR KEY PLAN
KEY NOTES - ICRA
NUMBER DESCRIPTION
1 HIGH EFFICIENCY PARTICULATE AIR-EQUIPPED (HEPA) FILTRATION MACHINE RATED AT 95% CAPTURE OF 0.3 MICRONS
INCLUDING POLLEN, MOLD SPORES, AND DUST PARTICLES
2 HEAVY DUTY, FLEXIBLE STEEL REINFORCED HEPA EXHAUST DIRECTLY VENTED TO EXTERIOR
3 REMOVE PORTION OF EXISTING LEAD LINED FURRING PARTITION & EXTERIOR GLAZING BEYOND. INSTALL PLYWOOD WITH
SEALED EXHAUST PORT. SEE B/GC101 FOR DETAIL
4 EXISTING SUPPLY & RETURN DUCTING IS TO BE SEALED OFF FOR INFECTION CONTROL THROUGHOUT DEMOLITION &
CONSTRUCTION
1 1/2" = 1'-0"B
TYPICAL HEPA FILTRATION THROUGH WINDOW DETAIL
DOOR AND FRAME SCHEDULE ICRA
DOOR NO.
DOOR FRAME
FIRE
RATING
HARDWARE
SET (HW) KICK PLATE REMARKS DOOR NO.
SIZE
TYPE MATERIAL TYPE MATERIAL
DETAIL
WIDTH HEIGHT THICKNESS HEAD JAMB SILL
TD1 3'-0" 7'-0" 1 3/4" F WD 1 HM H1 J1 - C T01 - - TD1
DOOR JAMBS DOOR TYPESDOOR FRAMES
4x PIPE∅
8" MIN.
EXISTING LEAD-LINED GYPSUM BOARD PARTITION
NEW LEAD SHIELDING WITH 2" WIDE
OVERLAP. LEAD SHIELDING EQUAL TO
THICKNESS IN WALL.
EXISTING IN-WALL MOUNTED DEVICE
REMOVED FROM WALL, OPENING
VARIES. REFER TO DEMO DRAWINGS
NEW 5/8" GYPSUM BOARD WITH LEAD
SHIELDING. LEAD SHIELDING EQUAL TO
THICKNESS IN WALL.
NEW LEAD SHIELDING WITH 2" WIDE
OVERLAP. LEAD SHIELDING EQUAL TO
THICKNESS IN WALL.
O P
E N
IN
G
V A
R
IE
S
"2
V A
R
IE
S
2" VARIES 2"
OPENING
ELEVATION SECTION
ELEVATION SECTION
SHIELDED ROOM
SIDE
LEAD-LINED GYPSUM BOARD
NEW LEAD SHIELDING WITH 2" WIDE
OVERLAP. NEW LEAD SHIELDING EQUAL
TO THICKNESS IN WALL
NEW IN-WALL MOUNTED DEVICE, AS
REQUIRED BY ARCH/MEP/EQUIP
DRAWINGS
NEW LEAD SHIELDING AROUND ALL
SIDES OF BOX/OPENING. LEAD SHIELDING
EQUAL TO THICKNESS IN WALL
NEW LEAD SHIELDING WITH 2" WIDE
OVERLAP. NEW LEAD SHIELDING EQUAL
TO THICKNESS IN WALL
O P
E N
IN
G
V A
R
IE
S
PIPE
X
P
IP
E D
IA
P
IP
E
LEAD SHIELDING EQUAL TO
THICKNESS IN WALL. WRAP
AROUND CIRCUMFERENCE
OF PIPE.
PIPE OR CONDUIT
LEAD-LINED GYPSUM BOARD
4x LARGEST
DIMENSION OF
DUCT
NOTE: ALL PENETRATION AT
LEAD WALLS TO BE SHIELDED
LEAD SHIELDING EQUAL TO LEAD SHIELDING
REQUIRED FOR WALL. WRAP AROUND ALL
SIDES OF DUCT WITH 2" LAPS AS REQUIRED
LA
R
G E
S T
D
IM
E
N S
IO
N
O F
D
U C
T
SHIELDED ROOM
SIDE
SHIELDED ROOM
SIDE
4x LARGEST
DIMENSION OF
DUCT
LEAD-LINED GYPSUM BOARD
LEAD SHIELDING EQUAL TO LEAD SHIELDING
REQUIRED FOR WALL. WRAP AROUND ALL
SIDES OF DUCT WITH 2" LAPS AS REQUIRED
FINISH FLOOR SURFACE. REFERENCE
FINISH SCHEDULE. INSTALL FLOOR FINISH
AS PER MANUFACTURER'S WRITTEN
INSTRUCTIONS FOR INSTALLATION ON LEAD
FLOOR.
NEW LEAD (THICKNESS TO MATCH
EXISTING) GLUED TO EXISTING CONCRETE
SURFACE. LEVEL AND PREP CONCRETE
AS REQUIRED. PAINT CONCRETE WITH
EPOXY PAINT.
2" LEAD LAP
EXISTING CONCRETE FLOOR
LEVEL FLOOR ABOVE LEAD AS
REQUIRED WITH FLOOR LEVELER.
TAPER FLASHING AT DOOR OPENINGS
LEAD (THICKNESS TO MATCH EXSITING) WRAP
AROUND CIRCUMFERENCE OF PIPE, CONTINUOUS
THROUGH FLOOR PENETRATION
PIPE, SIZE VARIES
4x
D
IA
P
IP
E
GALVANIZED IRON SLEEVE
C O
N C
S
LA
B
V
A R
IE
S
CLAMP.
4x
D
IA
P
IP
E
SHIELDED ROOM
SIDE
FOLD LEAD SHIELDING OVER
CABINET ATTACHMENT AS
SHOWN
5/8" GYPSUM BOARD WITH 1/8"
LEAD SHIELDING
CABINET / ACCESSORY
METAL STRAPPING AS
REQUIRED
LEAD DETAIL - INFILL OPENINGLEAD DETAIL - NEW DEVICE
LEAD DETAIL - PIPE PENETRATION
LEAD DETAIL - DUCT PENETRATION LEAD DETAIL - PIPE FLOOR PENETRATIONLEAD DETAIL - FLOOR
LEAD DETAIL -CABINET/ACCESSORY
WALL ATTACHMENT
5/8" GYPSUM BOARD WITH 1/8"
LEAD SHIELDING
NEW LEAD (THICKNESS TO MATCH
EXISTING) ATTACHED TO FACE OF
EXISTING MASONRY WALLS. WRAP LEAD
AROUND AS SHOWN. CONTINUE LEAD
FROM FLOOR TO 6" ABOVE LEAD
CEILING. TYPICAL AT ALL HAT
CHANNELS SUPPORTING GWB WITH
LEAD SHIELDING.
SHIELDED ROOM
SIDE
LEAD DETAIL - LEAD GYPSUM
BOARD FURRING
7/8" VERTICAL METAL HAT FURRING @ 16" O.C.
EXIST MASONRY CONSTRUCTION
/1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
ACELAJLH
C U s e rs \a k a n u s k y \D o c u m e n ts
\5
-1
-1
E D
D E
P T
V
A B
U F
F A
L O r2
X
-R a y C
M a k a n u s k y V
B N
S Y
.r v t
/1
/2
:4
:3
A
M
GC102
LEAD SHIELDING DETAILS
3/22/2022
BUFFALO VA MEDICAL CENTER
528-19-104X-RAY RENOVATION100% FINAL BID SUBMISSION
PARTIALLY SPRINKLERED
21-USDVA-04
3" = 1'-0"1
TYPICAL LEAD SHIELDING DETAILS
Revisions: Date: NY LIC. NO.:
043141
VHAWNYHELDWT
Text Box No lead expected / required for floor shielding
VHAWNYHELDWT
Highlight
VHAWNYHELDWT
Highlight
VHAWNYHELDWT
Highlight
SCOPE OF ABATEMENT WORK. REFER TO KEY NOTES, GENERAL
NOTES AND SUMMARY OF MATERIALS FOR ADDITIONAL
INFORMATION
THREE (3) STAGE PERSONAL DECONTAMINATION UNIT. INSTALL AT
CONTAINMENT WORK AREAS AS REQUIRED
CLEAN ROOM
SHOWER ROOM
EQUIPMENT / DIRTY ROOM
PATH OF TRAVEL
AREA GENERALLY NOT IN SCOPE OF WORK
1. FURNISH ALL LABOR, MATERIALS, EQUIPMENT AND SERVICES NECESSARY FOR THE REMOVAL AND DISPOSAL OF ASBESTOS-CONTAINING MATERIALS AS NOTED INCLUDING THE REMOVAL OF ALL NON
ASBESTOS-CONTAINING MATERIALS SUCH AS VINYL AND CERAMIC FLOORING, AND ANY
DEMOLITION, REMOVAL AND DISPOSAL NECESSARY TO EXPOSE ASBESTOS CONTAINING
MATERIALS AND DEBRIS INCLUDING ALL REQUIRED PREPARATION, CLEANING, ENCAPSULATION
AND DECONTAMINATION IN ACCORDANCE WITH ALL REGULATORY AGENCY REQUIREMENTS AND
THE PROJECT PLANS AND SPECIFICATIONS.
2. IF SUSPECTED ASBESTOS OR HAZARDOUS MATERIAL IS ENCOUNTERED DURING CONSTRUCTION, THE CONTRACTOR SHALL STOP WORK IMMEDIATELY, AND NOTIFY THE OWNER/ARCHITECT IN
WRITING, PRIOR TO CONTINUING WORK.
3. INSTALL CRITICAL BARRIERS AND WARNING SIGNS TO ESTABLISH ABATEMENT WORK AREAS PRIOR
TO THE START OF REMOVAL AND DISPOSAL OF HAZARDOUS MATERIALS PER THE PROJECT
SPECIFICATIONS.
4. INSTALL NEGATIVE AIR MACHINE FOR LOCAL EXHAUST VENTILATION BASED ON SITE CONDITIONS, BEST PRACTICES, AND SPECIFICATIONS. CONFIGURE AND PLACE NEGATIVE AIR MACHINES AS
NEEDED TO MAXIMIZE AIR MOVEMENT AND TO ACHIEVE FOUR (4) AIR CHANGES PER HOUR.
COORDINATE NEGATIVE AIR DISCHARGE LOCATIONS TO EXHAUST OUTSIDE OF BUILDING.
5. INSTALL FULL CONTAINMENT INCLUDING THREE STAGE PERSONAL DECONTAMINATION UNIT.
6. FOR MATERIALS REPORTED TO CONTAIN <1% ASBESTOS, FOLLOW OSHA REQUIREMENTS FOR
MATERIALS WITH 1% OR LESS ASBESTOS, INCLUDING WET HANDLING, CLEAN UP, DISPOSAL IN LEAK
TIGHT CONTAINERS, AND AN EXPOSURE ASSESSMENT.
7. FLAKING AND PEELING LEAD BASED PAINT ON SURFACES TO REMAIN SHALL BE REMOVED,
STABILIZED, AND ENCAPSULATED PRIOR TO CONTINUATION OF WORK.
8. AN ASBESTOS AND LEAD BASED PAINT SURVEY REPORT FOR THE ENTIRE AREA IS INCLUDED IN THE
SPECIFICATIONS.
9. EXISTING HVAC SYSTEM IS TO BE SHUT DOWN AND SEALED OFF AT ROOM DURING DEMOLITION
AND CONSTRUCTION TO PREVENT DUST AND HAZARDOUS MATERIALS FROM TRAVELING THROUGH
VENTILATION.
PET / CT
CORRIDOR
CONTROL ROOM
CONFERENCE
BREAK ROOM
COUNTER
TOILET
STORAGE
X-RAY
104D
X-RAY
CONTROL
ROOM
104D-1
DECONTAMINATION
UNIT
PET / CT
CORRIDOR
CONTROL
ROOM
OFFICE
101-E 102-E
137-E
136-E
132-E
133-E
131-E130-E129-E
146D-1
147-D
100E-18
126-E127-E128-E
101-A
125-E 124-E
123-E
100E-17
104-A
100A-4
101A-1
102-1
100A-1
100-A
148D-1
147D-1149-D
154-D153-D152-D151-D
135E-1
LOBBY
100A-2
101-3
101-D
100A-3
106-3 106-2
105-1
106-1
120-1
122 124
STAIR NO.1
ELEV. ELEV. ELEV. ELEV. ELEV.
ELEV.ELEV.ELEV.ELEV.ELEV.
ELEV.
ELEV.
STAIR NO.14
REGISTRATION
140D
WAITING
139D
IT
VENDING
TRIAGE
106D
NOURISH
109D
FAST-TRACK EXAM
110D
FAST-TRACK EXAM
111D
NURSE'S STATION
127D TREATMENT #1
128D
TREATMENT #2
129D
TREATMENT #3
130D
TREATMENT #4
131D
TREATMENT #5
132D
AMBULANCE BAY
STORAGE
STAFF
RESTROOM
126D
STAIR
#6
STORAGE
133D1
ISOLATION
TRAUMA
138D
SOILED UTILITY
137D
PSYCH.
HOLDING
136 RESTROOM
134D
PET / CT
CORRIDOR
CONTROL
ROOM
OFFICE
101-E 102-E
EQUIP.
ALCOVE
CORRIDOR
144-E139-E 143-E
CORRIDOR
137-E
136-E
132-E
134-E
133-E 132-E1
131-E130-E129-E
146D-1
100E-18
126-E127-E128-E
101-A
125-E 124-E
123-E
100E-17
104-A
100A-4
101A-1
102-1
100A-1
100-A
148D-1
147D-1149-D
154-D153-D152-D151-D
100A-2
101-3
101-D
106-3 106-2
105-1
106-1
120-1
122 124
126130
ELEV. ELEV. ELEV. ELEV. ELEV.
ELEV.ELEV.ELEV.ELEV.ELEV.
ELEV.
ELEV.
PN
N
GENERAL AREA OF WORK
EXISTING IT CLOSET 138-E
EXISTING ELECTRICAL
PANEL 'BPH-1'
(BASEMENT)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
ACELAJLH
C U s e rs \a k a n u s k y \D o c u m e n ts
\5
-1
-1
E D
D E
P T
V
A B
U F
F A
L O r2
X
-R a y C
M a k a n u s k y V
B N
S Y
.r v t
/2
/2
:3
:4
A
M
HA101
1ST FLOOR ABATEMENT PLAN
3/22/2022
BUFFALO VA MEDICAL CENTER
528-19-104X-RAY RENOVATION100% FINAL BID SUBMISSION
PARTIALLY SPRINKLERED
21-USDVA-04
ABATEMENT KEY NOTES
NUMBER DESCRIPTION
1 REMOVE RECESSED DOWNLIGHT WIRING WHIPS IN ACCORDANCE WITH THE SPECIFICATIONS, ALL APPLICABLE FEDERAL, STATE, AND
LOCAL REGULATIONS AND THE APPROVED HAZARD ABATEMENT PLAN
2 REMOVE 12X12 VAT FLOOR TILE AND MASTIC. ESTABLISH FULL CONTAINMENT WITH NEGATIVE PRESSURE EXHAUST TO REMOVE ASBESTOS CONTAINING MASTIC IN ACCORDANCE WITH THE SPECIFICATIONS, ALL APPLICABLE FEDERAL, STATE, AND LOCAL
REGULATIONS, AND THE APPROVED HAZARD ABATEMENT PLAN
3 HIGH EFFICIENCY PARTICULATE AIR-EQUIPPED (HEPA) FILTRATION MACHINE RATED AT 95% CAPTURE OF 0.3 MICRONS INCLUDING
POLLEN, MOLD SPORES, AND DUST PARTICLES
4 HEAVY DUTY, FLEXIBLE STEEL REINFORCED HEPA EXHAUST DIRECTLY VENTED TO EXTERIOR
5 REMOVE PORTION OF EXISTING LEAD LINED FURRING PARTITION & EXTERIOR GLAZING BEYOND. INSTALL PLYWOOD WITH SEALED
EXHAUST PORT. SEE B/GC101 FOR DETAIL
6 EXISTING SUPPLY & RETURN DUCTING IS TO BE SEALED OFF FOR INFECTION CONTROL THROUGHOUT DEMOLITION & CONSTRUCTION
7 WATER SUPPLY FOR DECONTAMINATION UNIT IS TO TAP OFF OF EXISTING SUPPLY LINES WITHIN CORRIDOR. DO NOT CONNECT WITHIN
AREA OF ABATEMENT SCOPE
8 MATERIALS ARE TO BE DOUBLE BAGGED & TRANSPORTED IN COVERED BINS TO THE ELEVATORS. CONTRACTOR IS TO TAKE COVERED
BINS DOWN TO BASEMENT AND OUT TO WING-C LOADING DOCK
LEGEND - ABATEMENT
SUMMARY OF MATERIALS TO BE ABATED
DESCRIPTION CATEGORY QUANTITY
RECESSED DOWNLIGHT WIRING WHIPS NON-FRIABLE 16 LIGHT FIXTURES (48 SF APPROXIMATELY)
12X12 VINYL ASBESTOS TILE & ASSOCIATED
MASTIC
- 380 SF OF FLOOR TILE & ASSOCAITED MASTIC
ABATEMENT GENERAL NOTES
1/8" = 1'-0"1
FIRST FLOOR ASBESTOS / LEAD ABATEMENT PLAN FIRST FLOOR KEY PLAN
1. REFER TO SPECIFICATIONS SECTION 024119 - SELECTIVE DEMOLITION FOR ADDITIONAL REQUIREMENTS AND INFORMATION
2. PROJECT SCOPE LINE IS INDICATED FOR GENERAL INTENT ONLY. ADDITIONAL DEMOLITION WILL BE REQUIRED OUTSIDE OF THIS LINE.
ARCHITECTURAL DEMOLITION DRAWINGS ARE FOR SCHEMATIC PURPOSES. CONTRACTOR SHALL COORDINATE ALL DEMOLITION WITH THE ENTIRE SET OF CONTRACT DOCUMENTS FOR FULL SCOPE OF DEMOLITION WORK REQUIRED FOR THE PROJECT. DEMOLITION BACK TO
SOURCE IS REQUIRED
3. EXISTING CONDITIONS SHOWN ON THESE DRAWINGS ARE NOT GUARANTEED TO BE COMPLETE. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, DIMENSIONS AND MATERIALS REQUIRED FOR THE CONTRACTED WORK. REPORT ALL DISCREPANCIES TO ARCHITECT
PRIOR TO FABRICATION, ERECTION AND/OR INSTALLATION
4. COORDINATE ALL NEW PENETRATIONS AND/OR OPENINGS WITH OTHER ASSOCIATED TRADES
5. THE OWNER MAY SELECT AND TAG ITEMS FOR DEMOLITION TO BE SALVAGED. THE CONTRACTOR SHALL REMOVE SELECTED ITEMS FROM
SCOPE OF WORK AND DELIVER TO THE OWNER'S LOCATION WITHIN THE EXISTING FACILITY
6. CONTRACTOR SHALL PROVIDE HEPA FILTERED NEGATIVE AIR MACHINE(S) TO MAINTAIN NEGATIVE PRESSURE TO SCOPE OF WORK AREA ENSURING NO DUST WILL BE TRANSFERRED TO OCCUPIED AREAS. PROVIDE VISUAL PRESSURE MONITORING DEVICE AT DUST PROOF
BARRICADE TO CONFIRM PRESSURE
7. THE FACILITY'S EXISTING SMOKE AND FIRE SUPPRESSION SYSTEM SHALL REMAIN IN OPERATION DURING THE ENTIRE CONSTRUCTION PHASE.
ILSM ALLOWS FOR 8 HOUR SHUTDOWNS OF ALARMS WHICH ARE COVERED PRIOR TO WORK. FIRE SUPRESSION NEEDS TO BE STRICTLY COORDINATED FOR ANY 8 HOUR SHUTDOWN AND THE AREA OF WORK NEEDS TO BE PHYSICALLY MONITORED DURING SHUTDOWNS
8. ALL DEMOLITION WORK BEING DONE OUTSIDE OF TEMPORARY PARTITIONS IS TO BE APPROPRIATELY SEALED OFF TO PREVENT THE TRANSMISSION OF DUST AND DEBRIS AND MINIMIZE DISRUPTION TO VISITORS, RESIDENTS AND STAFF. COORDINATE LOCATION OF BARRIERS
WITH COR AND INFECTION CONTROL TEAM
9. PREPARE ALL ADJACENT SURFACES TO RECEIVE NEW CONSTRUCTION AND SCHEDULED FINISH. EXISTING WALLS SHOWN TO BE REMOVED SHALL BE DEMOLISHED COMPLETELY. THIS INCLUDES THE REMOVAL OF REINFORCEMENT, SOFFITS, DOORS, WINDOWS, FRAMES AND OVERHEAD BRACING. COORDINATE WITH MECHANICAL AND ELECTRICAL FOR DISCONNECTION AND REMOVAL OF EXISTING UTILITIES AND
DEVICES LOCATED WITHIN AREAS SCHEDULED TO BE DEMOLISHED
10. SOME ITEMS MAY BE INDICATED IN THE DEMOLITION DRAWINGS AND DEMOLITION NOTES WHICH ARE NOT NECESSARILY DEMOLITION WORK BUT ARE INCLUDED TO DESCRIBE THE OVERALL SCOPE OF THE PROJECT AND TO AID IN THE DEMOLITION COORDINATION. THE CONTRACTOR IS RESPONSIBLE FOR ALL WORK REQUIRED TO COMPLETE THE INTENDED WORK OF THE OVERALL PROJECT
11. FLOORING DEMOLITION INCLUDES THE REMOVAL OF EXISTING FLOOR FINISHES, INCLUDING VCT, SHEET VINYL, CERAMIC TILE, QUARRY TILE, CARPET AND OTHER FINISHES, GROUTS, MASTICS AND SETTING BEDS COMPLETE TO EXISTING CONCRETE FLOOR SLAB OR OTHER SUBSTRATE READY FOR NEW FLOOR FINISHES. FLOOR PREP SHALL BE BY THE INSTALLING CONTRACTOR
12. REMOVE MISCELLANEOUS ITEMS WITHIN LIMITS OF DEMOLITION. COORDINATE WITH OWNER ANY ITEMS TO BE SALVAGED
13. DEMOLITION OF CEILINGS INCLUDES GRID, TILE, SUPPORTS, SOFFITS AND RELATED ITEMS, UNLESS NOTED OTHERWISE. COORDINATE WITH ELECTRICAL WORK ON REMOVAL OF LIGHTS, CONDUIT, TIES, SUPPORTS AND RELATED WIRING. COORDINATE WITH MECHANICAL ON REMOVAL
OF DIFFUSERS GRILLS, AND RELATED DUCTWORK EQUIPMENT CONTAINED THEREIN
14. PLUG ABANDONED FLOOR OPENINGS WITH NEW CONCRETE. PLUG SHALL MATCH EXISTING SLAB DEPTH AND BE STRUCTURALLY SOUND TO
CARRY FLOOR LOAD OF 100 LBS. / SQ. FT. UNLESS NOTED OTHERWISE
15. ALL FIRE RATED ASSEMBLIES (COLUMNS, SHAFTS, WALLS, ETC.) SHALL BE MAINTAINED OR BE RELOCATED / PATCHED. MATCH EXISTING FIRE
RATING UNLESS NOTED OTHERWISE
16. REMOVE EXISTING DOORS, FRAMES, SIDELIGHTS, ANCHORS, THRESHOLDS AND HARDWARE AS INDICATED WITHIN LIMITS OF CONSTRUCTION.
PATCH AND REPAIR WALL AND FLOOR TO MATCH EXISTING. OWNER SHALL HAVE THE RIGHT TO SALVAGE ANY AND ALL DOORS AND HARDWARE. CONTRACTOR SHALL VERIFY DOORS FOR SALVAGE OR RELOCATION PRIOR TO COMMENCING DEMOLITION
17. PROTECT EXISTING FINISHED WORK & EQUIPMENT WHICH IS TO REMAIN IN AREAS OF DEMOLITION WORK
18. AFTER THE REMOVAL OF ICRA WALLS, CLEAN AND PATCH EXISTING WALLS AND CEILINGS EFFECTED BY CONSTRUCTION AND MATCH EXISTING
FINISHES
X-RAY
104D
X-RAY
CONTROL ROOM
104D-1
TRIAGE
106D
CORRIDOR
1A
PN
N
GENERAL AREA OF WORK
EXISTING IT CLOSET 138-E
EXISTING ELECTRICAL
PANEL 'BPH-1'
(BASEMENT)
A
A
B
A
C
X-RAY
CONTROL ROOM
104D-1
X-RAY
104D
A
A
D
D
E
F
F
TRIAGE
106D
CORRIDOR
G
EXISTING CONSTRUCTION TO REMAIN. PATCH AS
REQUIRED BY THE SPECIFICATIONS WITHIN THE
CONTRACT AREA.
AREA GENERALLY NOT INCLUDED IN CONTRACT
EXISTING ACOUSTICAL CEILING TILE SYSTEM TO BE
REMOVED
EXISTING LIGHT FIXTURE(S) TO BE REMOVED. SEE
ELECTRICAL DRAWINGS.
EXISTING MECHANICAL GRILLES TO BE REMOVED.
GC TO MODIFY MECHANICAL SYSTEM AS REQUIRED.
SEE MECHANICAL DRAWINGS
SPRINKLER HEAD TO BE REMOVED - REFER TO
ENGINEERING DRAWINGS
AREA GENERALLY NOT INCLUDED IN CONTRACT
A
B
C
C
E
E
A
D
D
A
F
F
F
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
ACELAJLH
C U s e rs \a k a n u s k y \D o c u m e n ts
\5
-1
-1
E D
D E
P T
V
A B
U F
F A
L O r2
X
-R a y C
M a k a n u s k y V
B N
S Y
.r v t
/1
/2
:4
:1
A
M
AD101
1ST FLOOR DEMOLITION PLANS
3/22/2022
BUFFALO VA MEDICAL CENTER
528-19-104X-RAY RENOVATION100% FINAL BID SUBMISSION
PARTIALLY SPRINKLERED
21-USDVA-04
GENERAL DEMOLITION NOTES
1/4" = 1'-0"1
1ST FLOOR - DEMOLITION PLAN
FIRST FLOOR KEY PLAN
1/4" = 1'-0"2
1ST FLOOR - DEMOLITION RCP
LEGEND - DEMOLITION PLAN
LEGEND - DEMOLITION REFLECTED CEILING PLAN
DEMOLITION KEY NOTES - FLOOR PLAN
NUMBER DESCRIPTION
1 DEMOLISH ALL FLOORING, WALL BASE, CASEWORK, AND WALL FINISHES IN THEIR ENTIRETY. EXISTING FURNITURE IS TO BE REMOVED, GC IS TO CONFIRM WITH PROJECT COR WHAT ITEMS ARE TO BE SALAVGED. SEE ENGINEERING DRAWINGS FOR
COORDINATION WITH OTHER TRADES
1A EXISTING SLAB IS TO BE PREPPED FOR NEW FLOORING. SLAB IS TO BE LEVELED AS REQUIRED WITHIN 3/16" OVER 3'-0" AS REQUIRED BY X-RAY MANUFACTURER. TAKE CARE TO PROTECT EXISTING LEAD LINING AT THE FLOOR SLAB AS REQUIRED
2 REMOVE EXISTING X-RAY UNIT & ASSOCIATED EQUIPMENT INCLUDING CEILING MOUNTED DEVICES. PREPARE TO RECEIVE NEW UNIT
& COORDINATING EQUIPMENT
3 EXISTING WALL MOUNTED LAVATORY IS TO REMAIN & BE PROTECTED DURING DEMOLITION & CONSTRUCTION
4 REMOVE EXISTING UPS UNITS FOR EXISTING UNIT. REFER TO ELECTRICAL DEMOLITION PLANS FOR MORE INFORMATION
5 REMOVE EXISTING CONTROL MODULE FOR EXISTING X-RAY UNIT. REFER TO ELECTRICAL PLANS FOR MORE INFORMATION
6 REMOVE EXISTING JUNCTION BOX FOR EXISTING X-RAY UNIT. REFER TO ELECTRICAL PLANS FOR MORE INFORMATION
7 REMOVE EXISTING ELECTRICAL RACEWAY & PREP WALL TO RECEIVE NEW FINISH
8 REMOVE EXISTING ELECTRICAL EQUIPMENT FOR EXISTING X-RAY UNIT. REFER TO ELECTRICAL DRAWINGS FOR MORE INFORMATION
9 EXISTING MECHANICAL UNIT IS TO REMAIN & BE PROTECTED DURING DEMOLITION & CONSTRUCTION. HVAC SYSTEM IS TO BE SHUT
DOWN DURING DEMOLITION & CONSTRUCTION.
DEMOLITION RCP KEY NOTES
NUMBER DESCRIPTION
A EXISTING GYPSUM BOARD SOFFIT IS TO REMAIN & BE PROTECTED DURING DEMOLITION & CONSTRUCTION
B EXISTING UNISTRUT SYSTEM IS TO BE MODIFIED FOR NEW CEILING HEIGHT - REFER TO NEW WORK PLANS
FOR NEW CEILING HEIGHT
C EXISTING PATIENT LIFT IS TO BE REMOVED & SALVAGED FOR RE-USE IN NEW CONSTRUCTION
D EXISTING HVAC SYSTEM IS TO BE SHUT DOWN DURING DEMOLITION & CONSTRUCTION. EXISTING SUPPLY &
RETURN DUCTING IS TO BE SEALED OFF FOR INFECTION CONTROL THROUGHOUT DEMOLITION &
CONSTRUCTION. LINEAR DIFFUSERS ARE TO BE REMOVED & SALVAGED FOR RE-USE IN NEW CEILING. REFER
TO NEW WORK PLANS FOR NEW CEILING INFORMATION.
E EXISTING X-RAY UNIT RAIL SYSTEM IS TO BE REMOVED IN ITS ENTIRETY
F EXISTING ACOUSTICAL GRID & TILES ARE TO BE REMOVED THROUGHOUT
G EXISTING INDICATOR LIGHT IS TO REMAIN & BE PROTECTED DURING DEMOLITION & CONSTRUCTION
ARCHITECTURAL FINISHES DEMOLITION
ROOM NAME
ROOM
NUMBER FLOOR FINISH
WALL BASE
FINISH WALL FINISH CEILING FINISH MATERIAL TO BE ABATED
X-RAY 104D 12X12 VAT TILE VINYL COVE PAINT 2X2 ACT TILE RECESSED DOWNLIGHT
WIRING WHIPS & 12X12 VAT
TILE W/ MASTIC
X-RAY CONTROL
ROOM
104D-1 12X12 VAT TILE VINYL COVE PAINT 2X2 ACT TILE & GWB
SOFFITS
RECESSED DOWNLIGHT
WIRING WHIPS & 12X12 VAT
TILE W/ MASTIC
X
1 1/2" = 1'-0"A
EXISTING CONDITION PHOTOS - X-RAY
X-RAY
104D
X-RAY
CONTROL ROOM
104D-1
'-6
3'-9"
3'-11"
6"
AE101
CORRIDOR
SF101
SF101
PN
N
GENERAL AREA OF WORK
EXISTING IT CLOSET 138-E
EXISTING ELECTRICAL
PANEL 'BPH-1'
(BASEMENT)
AT-1
7'-7 1/2"
A
B
C
AT-1
7'-7 1/2"
AT-1
7'-7 1/2"
D
D
D
D
AT-1
9'-6"
X-RAY
104D
X-RAY
CONTROL ROOM
104D-1
CORRIDOR
AE101
TYP.
F
SF101
NEW 2x2 ACOUSTICAL CEILING TILE TO BE
PLACED IN EXISTING GRID SYSTEM
SPRINKLER HEAD
SUPPLY AIR GRILLE
RECESSED LINEAR LIGHT FIXTURE
AREA OF WORK NOT INCLUDED IN CONTRACT
AREA TO BE KEPT CLEAR OF CEILING FIXTURES & OTHER
NON-SYSTEM ITEMS THAT MAY PROJECT DOWNWARD
FROM THE CEILING
LINEAR DIFFUSER - REFER TO MECHANICAL DRAWINGS
FOR MORE INFORMATION
EXISTING CONSTRUCTION TO REMAIN. PATCH AS
REQUIRED FOR NEW FINISHES IF INDICATED ON
FINISH SCHEDULE.
AREA OF WORK NOT INCLUDED IN CONTRACT
EXISTING WALL MOUNTED LAVATORY
NEW COUNTER
EXISTING GLAZING SYSTEM
TO REMAIN - FRAME TO BE
PAINTED (P-4)
OPEN
BEYOND
AE101
(S-1) SOLID SURFACE
COUNTERTOP
POWDER-COATED HEAVY DUTY
WORKSURFACE BRACKET; WHITE.
SPACE BASED ON MANUFACTURER'S
RECOMMENDATION
/2
SOLID SURFACE COUNTERTOP
ATOP PLYWOOD SUBSTRATE
2'-6"
CUTOUT FOR GROMMETS
(GROM-1) AS REQUIRED. REFER
TO PLAN FOR LOCATION /
QUANTITY
POWDER COATED SUPPORT
BRACKET (BR-1) - SPACED AS
RECOMMENDED BY
MANUFACTURER
1. REFER TO CEILING PLAN FOR CEILING HEIGHTS AND REFER TO LEGEND FOR CEILING
TYPES.
2. WHERE THE LIGHTS AND ACCESSORIES ARE SHOWN TO BE RECESSED IN CEILING
TILES, THEY SHALL BE CENTERED OR EDGE ALIGNED IN THE CEILING TILES, AS
INDICATED GRAPHICALLY, UNLESS NOTED OTHERWISE.
3. REFER TO ELECTRICAL DRAWINGS FOR LIGHT FIXTURE DESCRIPTIONS AND ALL CEILING
MOUNTED ELECTRICAL DEVICES.
4. REFER TO MECHANICAL DRAWINGS FOR DIFFUSER DESCRIPTIONS AND ALL CEILING
MOUNTED MECHANICAL DEVICES.
5. REFER TO TECHNOLOGY DRAWINGS FOR IDENTIFICATION AND DESCRIPTION OF
CEILING MOUNTED TECHNOLOGY EQUIPMENT.
6. CEILING HEIGHT DIMENSIONS SHOWN ON REFLECTED CEILING PLAN AND DETAILS ARE
FROM FINISH FLOOR TO FINISH CEILING.
7. UNLESS NOTED OTHERWISE, LIGHT FIXTURES SHALL BE LOCATED AS SHOWN ON THE
REFLECTED CEILING PLANS.
8. WHERE LIGHT FIXTURES, DEVICES AND ACCESSORIES ARE SHOWN TO BE RECESSED IN
CEILING TILES, THEY SHALL BE CENTERED IN THE CEILING TILES UNLESS NOTED
OTHERWISE.
9. PROVIDE ACCESS PANELS AS REQUIRED BY APPLICABLE CODES AND AS REQUIRED
FOR MECHANICAL, ELECTRICAL, AND PLUMBING EQUIPMENT. ACCESS PANELS LOCATED
IN FINISHED AREAS SHALL BE PAINTED TO MATCH ADJACENT SURFACES. LOCATIONS
SHALL BE REVIEWED WITH THE ARCHITECT PRIOR TO PROCEEDING WITH THE
INSTALLATION.
10. ALL GYPSUM. BOARD CEILINGS AND SOFFITS ARE TO BE PAINTED - REFER TO FINISH
PLANS FOR SPECIFICATION INFORMATION.
11. NO MECHANICAL EQUIPMENT IN THE CEILING CAVITY REQUIRING NORMAL
MAINTENANCE SHALL BE INSTALLED ABOVE A GYPSUM. BOARD CEILING. NOTIFY
ARCHITECT IF ANY SUCH ITEMS ARE INDICATED ABOVE GYPSUM. BOARD CEILINGS.
12. EXIT SIGNS AND SMOKE DETECTORS LOCATED IN HARD CEILINGS SHALL BE CENTERED
IN CORRIDORS AND LOCATED A DISTANCE OF 1’-0” FROM WALL TO THE CENTER OF THE
FIXTURE UNLESS NOTED OTHERWISE. LOCATE EXIT SIGNS AS REQUIRED BY THE
AUTHORITY HAVING JURISDICTION.
13. SOFFITS AND BULKHEADS SHALL BE LATERALLY BRACED TO RESIST HORIZONTAL
MOVEMENT.
14. CONTRACTOR SHALL COORDINATE ALL TYPES OF FIXTURES WITH ELECTRICAL
DRAWINGS. FIXTURES SHOWN ON ARCHITECTURAL DRAWINGS ARE FOR REFERENCE
ONLY AND ARE INDICATED FOR LOCATION ONLY.
15. PROVIDE AND INSTALL NEW LIGHT FIXTURES, SENSING AND OTHER DEVICES AS
INDICATED: SEE ELECTRICAL DRAWINGS FOR ADDITIONAL REQUIREMENTS.
16. PROVIDE AND INSTALL HVAC DIFFUSERS AND RETURN GRILLS AS INDICATED: SEE
MECHANICAL DRAWINGS FOR ADDITIONAL REQUIREMENTS.
17. PROVIDE AND INSTALL SPRINKLER HEAD LOCATIONS AS INDICATED: SEE FIRE
PROTECTION DRAWINGS FOR…