This document outlines a federal contract opportunity with the Department of Veterans Affairs for renovations to Cardiology Unit 4B. The solicitation number is 36C24220B0066 and concerns renovations specified in the drawings file "2020-12-02 4B Cardio - Amend_1 Drawings with Revisions.pdf." The opportunity type is a solicitation from the Veterans Health Administration Veterans Integrated Service Network 2 for project 528A7-18-726 to renovate Cardiology Unit 4B. The description provided indicates the solicitation concerns renovations to Cardiology Unit 4B but does not include any additional details on requirements, response timing, or award information.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COVER SHEET
AND
DRAWING INDEX
GI001
ARFTMH
DESIGN RENOVATION
FOR 4B CARDIOLOGY
528A7-18-726
B
A
C
D
E
F
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Revisions Date
Reviewed:
Reviewed:
Drawing Title Project Title
Location
Building Number Checked
Project No.
DRAWING NO.
Drawn
Date
Approved: Project Director
Reviewed: Facility Director
Reviewed: Facility Manager
BID DOCUMENTS
FULLY SPRINKLERED
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE WHATSOEVER
WITHOUT THE SEAL AND SIGNATURE OF THE PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0499-0126
Scient is ts | Engineers | Program Managers
Mabbett & Associates, Inc.
105 Central Street, Stoneham, MA 02180
T. 781-275-6050 www.mabbett.com
1 AMENDMENT #1 2020-11-30
N O P Q
R
R
S
S
T
T
U
U
UP
B426
B425B423B421
B424B422
B427
B418
B420
B419B417B415B413
B416 B410B408B406B404
B411
B436
B440
B442
B444
B446
B439
B441
B443
B445
B447
B437
B407 B409
B439A B413A
B416A
B414
B403
DESIGN RENOVATION
FOR 4B CARDIOLOGY
SYRACUSE VAMC, SYRACUSE, NY
528A7-18-726
2020-10-26 o n e e i g h t h i n c o e f o t
B
A
C
D
E
F t h r e e i n c h e s o t o n e a d a l f i n c h e s o t o n e i n o t t h r e e q u a r t e r s i n o t o n e h a l f i n o t t h r e e e i g h t h s i n o t o n e q u a r t e r i n o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Revisions Date
Reviewed:
Reviewed:
Drawing Title Project Title
Location
Building Number Checked
Project No.
DRAWING NO.
Drawn
Date
Approved: Project Director
Reviewed: Facility Director
Reviewed: Facility Manager
BID DOCUMENT
FULLY SPRINKLERED
ACTUAL
NORTH
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE WHATSOEVER
WITHOUT THE SEAL AND SIGNATURE OF THE PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned
Small Business
A
S r v i c e
D i s a b l
V t e r a
O w n
S m a l l
B u s i n e s s
SDVOSB
CVE
MR PROJECT NO: 0499-0126
KEYPLAN
AREA
OF WORK
Scientists I Engineers I Program Managers
Mabbett & Associates, Inc.
105 Central Street Stoneham, MA 02180
T. 781-275-6050 www.mabbett.com
Mabbett
R
MFD DJA
HA-101
FOURTH FLOOR, WING-B
BUILDING-1
ASBESTOS ABATEMENT PLAN
UP
REMOVE EXISTING WD BLOCKING
REMOVE EXISTING SSM WINDOW SILL & STOOL
EXISTING PRECAST CONCRETE
WINDOW SILL TO REMAIN
EXISTING ALUMINUM WINDOW SYSTEM TO REMAIN
WINDOW JAMB BEYOND
EXISTING BRICK VENEER, CMU AND
PLASTER FINISH TO REMAIN
N O P Q R S T U
B426
B425B423B421
B424B422
B427
B418
B420
B419B417B415B413
B416B410B408B406B404
B411
B436
B440
B442
B444
B446
B439
B441
B443
B445
B447
B437
B407 B409
B439A
B413A
B416A
B414
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01 R01
R01
R01
R01 R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01 R01 R01
R01
R01
R01
R01
R01 R01
R01
R01
R01
R01R01R01
R01
R01
R01
R01
R01
R01
R01
R01
R01R01R01
R01 R01
R02
R02
R02R02R02
R02R02R02
R02
R02
R02
R02
R02
R02R02R02R02R02
R02
R02
R02
R02 R02
R02 R02
R02 R02
R02
R02
R02
R02
R02
R02
R02 R02 R02 R02 R02
R02
R01
R16 R14
R16
R14
R16
R14
R16
R14
R16
R14
R16
R14
R16
R14
R16
R14
R16
R14
R16
R14
R16
R14
R16
R14
R16
R14
R16 R14 R16 R14 R16 R14 R16 R14
R16 R14 R16 R14 R16 R14 R16 R14
R16 R14 R16 R14 R16 R14 R16 R14
R16 R14 R16 R14
R16 R14 R16 R14 R16 R14 R16 R14R06R06R06
R06R06
R06R06R06R06
R06R13
R06
R13
R06
R06
R06
R06
R06
R06
R06
R06
R06
R06
R06
R06 R06 R06 R06
R06 R06 R06
R06
R06
R06
R06
R01
R01
R01
R01 R01 R01
R01 R01
R01
R01
R01
R01 R01
R01
R06
R06
R01
R06
R01
R01
R01R01
R01
R01
R01
R01
R06
R04R03R04R03R04R03
R04R03
R04R03R04R03R04R03R04R03R04R03R04R03R04R03
R04R03
R04R03
R04R03
R04R03
R04R03
R04R03
R04R03
R04R03
R04R03
R04R03
R04R03 R04R03
R04R03 R04R03 R04R03 R04R03
R04R03 R04R03
R04 R07
R04 R07 R04 R07
R04 R07
R04 R07
R01
R01 R01
R13
R13
R13
R13
R09
R05
R13
R08
4A
R06
R06
R08
R08
R02
R04R03 R04R03
R04R03
R01
R01
R01
R01
R01
R01
R01
R15
R06
R06
R10R10R10
R10R10
R10R10R10R10
R10
R10
R10
R10
R10
R10
R10
R10
R10
R10
R10
R10 R10 R10 R10
R10 R10 R10
R10
R10
R10
R12
R12
R02
EXISTING FLOOR
EXISTING WALL
PORTION OF TERRAZZO
COVE TO BE REMOVED
REMOVE COMPLETELY AND
FILL FOR FLUSH FINISH AT
WALLS TO BE REMOVED
1. THE CONTRACTOR SHALL NOT CONSIDER DEMOLITION AND ALTERATION NOTES TO BE ALL-INCLUSIVE. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO INSPECT AND ASSESS EACH AREA AND TO FULFILL THE DESIGN INTENT OF THE WORK INDICATED BY THE CONTRACT DOCUMENTS. ANY WORK NOT SPECIFICALLY SHOWN OR NOTED, BUT IS REASONABLY IMPLIED BY THE REMAINING DOCUMENTS WILL BE INCLUDED IN
THE CONTRACT.
2. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS WITHIN THE CONTRACT LIMITS AND NOTIFY THE COR IMMEDIATELY IN WRITING OF ANY DEVIATION FROM CONTRACT DOCUMENTS NECESSITATED BY FIELD CONDITIONS OR ITEMS NOT COVERED.
3. DASHED LINES ON DEMOLITION PLANS REPRESENT WALLS, DOORS, SOFFITS, CEILINGS, CASEWORK, ETC. TO BE REMOVED.
4. FOR ALL SURFACES SCHEDULED TO REMAIN, PATCH, MATCH SURFACES DISTURBED BY DEMOLITION OR REMOVAL OF EQUIPMENT OR UTILITIES.
PROVIDE PATCHING TO MATCH ADJACENT WORK IN FINISH, STRUCTURAL QUALITIES, COURSING OF MASONRY AND OTHER CHARACTERISTICS.
PATCH SURFACES TO COMPLY WITH FIRE RATINGS, SMOKE-TIGHT RATINGS, ACOUSTICAL CRITERIA AND OTHER PERFORMANCE CRITERIA INDICATED. PREPARE SURFACES AS NECESSARY TO PROVIDE A PROPER SUBSTRATE FOR SPECIFIED FINISH. REFINISH ENTIRE SURFACE CORNER TO CORNER AS NECESSARY TO PROVIDE AN EVEN FINISH TO MATCH ADJACENT FINISH. ALL WORK SHALL REFLECT HIGHEST LEVEL OF INDUSTRY
STANDARDS FOR EACH TRADE.
5. ALL DEMOLITION SHALL BE PERFORMED IN A SAFE AND ACCEPTABLE MANNER TO ALL AUTHORITIES HAVING JURISDICTION AND THE OWNER. A FIRE
WATCH SHALL BE PROVIDED AS REQUIRED BY VAMC AND APPLICABLE CODES.
6. PROVIDE TEMPORARY PARTITIONS/DUST PROTECTION (RATED AND/OR NON-RATED) AS REQUIRED BY ICRA. REVIEW LOCATIONS OF TEMPORARY PARTITIONS/DUST PROTECTION WITH COR PRIOR TO START OF WORK. REFER TO ICRA & LIFE SAFETY PLANS.
7. HAZARDOUS MATERIAL NOTE: CONTRACTOR SHALL STOP WORK AND INFORM OWNER IMMEDIATELY IN WRITING OF ANY HAZARDOUS MATERIAL ENCOUNTERED OR THOUGHT TO BE HAZARDOUS. COR, AFTER RECEIVING WRITTEN NOTICE, SHALL INSTRUCT CONTRACTOR HOW TO PROCEED.
8. ALL WORK SHALL BE DONE IN PROTECTED SPACE. NO DUST, DIRT OR LIQUID SHALL TRAVEL FROM CONSTRUCTION AREA TO ADJACENT AREAS.
TEMPORARY ICRA PARTITIONS SHALL BE ERECTED PRIOR TO COMMENCING WORK. REFER TO ICRA & LIFE SAFETY PLANS.
9. PRIOR TO ANY DEMOLITION THE CONTRACTOR SHALL COORDINATE BRACING AND MAINTAIN THE STRUCTURAL INTEGRITY OF THE REMAINING
ELEMENTS OF THE BUILDING AND ITS SYSTEMS AS REQUIRED.
10. COMPLY WITH GOVERNING REGULATIONS PERTAINING TO ENVIRONMENTAL PROTECTION FOR POLLUTION CONTROL. THOROUGHLY CLEAN ADJACENT AREAS OF DUST, DIRT AND DEBRIS CAUSED BY DEMOLITION WORK. BEFORE NEW WORK BEGINS, RETURN ADJACENT AREAS TO
CONDITION FOUND PRIOR TO START OF DEMOLITION WORK.
11. CONTRACTOR SHALL COORDINATE ARCHITECTURAL DEMOLITION DRAWINGS AND NOTES WITH MEP/FP DRAWINGS AND NOTES. PATCH OR REBUILD
ANY AREAS TO REMAIN THAT HAVE BEEN DISTURBED BY MEP/FP DEMOLITION.
12. CONTRACTOR SHALL REVIEW ALL ITEMS TO BE DEMOLISHED WITH COR TO IDENTIFY ANY ITEMS TO BE SALVAGED PRIOR TO START OF DEMOLITION.
13. ALL MATERIALS AND ITEMS REMOVED BY CONTRACTOR, UNLESS OTHERWISE NOTED, BECOME HIS PROPERTY AND ARE TO BE REMOVED FROM THE
SITE IN CLOSED CONTAINERS ON A DAILY BASIS OR IN MANNER ACCEPTABLE TO COR.
14. CONTRACTOR SHALL PREPARE FLOOR SLABS PER THE SPECIFICATION SO FINISH FLOORS ARE FLUSH WITH EACH OTHER AND PREPARED TO
ACCEPT NEW FINISH.
15. MAINTAIN ACCESS TO EXITS AND EXIT STAIRS AT ALL TIMES. FIRE ALARM AND SMOKE DETECTION SYSTEM SHALL REMAIN OPERATIONAL AT ALL TIMES. PROTECT SMOKE DETECTORS AS REQUIRED AND IN CONFORMANCE WITH CODES AND LOCAL AUTHORITIES HAVING JURISDICTION.
16. PRIOR TO DEMOLITION, CONTRACTOR SHALL PERFORM A THOROUGH ABOVE-CEILING INSPECTION FOR EXISTING SERVICES THAT ARE TO REMAIN
AND NOTIFY COR IMMEDIATELY OF ANY CONFLICTS WITH INSTALLATION OF NEW WORK.
17. ALL DEMOLITION WORK SHALL BE DONE IN ACCORDANCE WITH PHASING PLANS. MAINTAIN 44" MINIMUM CLEARANCE AT ALL CORRIDORS AT ANY
GIVEN TIME.
18. AFTER DEMOLITION IS COMPLETED AND PRIOR TO THE START OF CONSTRUCTION WORK, CONTRACTOR TO INSTALL CEMENTITIOUS UNDERLAYMENT OVER THE ENTIRE SLAB IN THE PROJECT AREA APPROXIMATELY 6,415 SQ. FT. FILL/PLUG ALL HOLES WATER TIGHT PRIOR TO INSTALLING
UNDERLAYMENT.
REMOVE PIPE, SEE PLUMBING DWGS
16 GA POUR STOP
FLR TOPPING
FLR FINISH
A Se rv ic e D i s a b le d Ve t e r an Owned
Sm a l l
B u s iness
SDVOSB
CVE
Location
Building Number
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0500-0016
o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t 6 o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
97 8654321
B
A
C
D
E
F
Revisions Date
ACTUAL
NORTH
Date
Project No.
Drawing NO.
Project Title
Checked Drawn
Drawing Title
Approved:
DESIGN RENOVATION
FOR 4B CARDIOLOGY
SYRACUSE VAMC, SYRACUSE, NY
Project Director
MILLER-REMICK LLCPROFESSIONAL ENGINEERPRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE PROFESSIONAL ENGINEER.
Reviewed: Facility Manager
Reviewed: Facility Director
Reviewed:
Reviewed:
2020-10-26
528A7-18-726
BID DOCUMENTS
FULLY SPRINKLERED
KEYPLAN
SH AE
AREA
OF
WORK
UP
DN
Scientists | Engineers | Program Managers
Mabbett & Associates, Inc.
105 Central Street, Stoneham, MA 02180
T.
781-275-6050 www.mabbett.com AD-101
4B DEMOLITION FLOOR PLAN
AND DETAILS
SCALE: 3/16" = 1'-0"
F1
FLOOR PLAN 4B-DEMO
KEYED NOTES-DEMOLITION
NUMBER COMMENT
R01 REMOVE MASONRY & PLASTER WALL SYSTEM, PATCH/REPAIR ANY FLOOR AND/OR CEILING SUBSTRATE DAMAGED BY REMOVAL. PREPARE EXISTING SUBSTRATE TO REMAIN AS REQUIRED TO RECEIVE NEW FINISH WORK. INFILL SLAB W/ CONC TO FLUSH W/ EXIST AT WALL REMOVALS. ALL WALL MOUNTED ACCESSORIES SHALL BE REMOVED AND DISPOSED OF. CONSULT WITH COR PRIOR TO REMOVAL TO DETERMINE WHAT ACCESSORIES ARE TO BE SALVAGED. REFER TO HA SERIES FOR AREAS WHERE THESE MATERIALS REQUIRE SPECIAL HANDLING.
R02 REMOVE DOOR, HM DOOR FRAME, HARDWARE AND ALL ASSOCIATED FASTENERS IN THEIR ENTIRETY.
R03 REMOVE VCT AND MASTIC FROM FLOOR SUBSTRATE, PATCH/REPARE ANY DAMAGE ASSOCIATED WITH REMOVAL AND PREPARE EXISTING SUBSTRATE TO RECEIVE NEW FINISH WORK. REFER TO HA SERIES DRAWINGS FOR AREAS WHERE THESE MATERIALS REQUIRE SPECIAL HANDLING.
R04 REMOVE ACOUSTICAL CEILING TILE, ASSOCIATED GRID, GWB SOFFITS, AND SUPPORT HANGERS. PATCH AND REPAIR ANY DAMAGE ASSOCIATED WITH REMOVAL AT EXISTING WALLS TO REMAIN. PREPARE WALLS TO RECEIVE NEW FINISH WORK AT EXISTING WALLS TO REMAIN.
R05 EXISTING CMU WALL & ELECTRICAL PANELS TO REMAIN.
R06 WALL TO REMAIN, ALL WALL MOUNTED ACCESSORIES SHALL BE REMOVED AND DISPOSED OF. VERIFY WITH COR PRIOR TO REMOVAL TO DETERMINE
WHAT ACCESSORIES THE OWNER WOULD LIKE TO SALVAGE.
R07 REMOVE FLOOR TILE AND SETTING BED, INFILL CONCRETE SLAB TO BE LEVEL WITH SURROUNDING SLAB.
R08 REMOVE WALL TILE AND SETTING MATERIAL ON WALLS TO REMAIN. PREPARE WALL FOR NEW FINISH.
R09 REMOVE CASEWORK AND ASSOCIATED HARDWARE & FASTENERS.
R10 REMOVE WALL BASES AND ANY ADHESIVES AND RESIDUES.
R12 DOOR TO REMAIN. PREP DOOR TO RECEIVE NEW PAINT.
R13 CUT/GRIND EXISTING COVED TERRAZZO BASE TO BE SQUARE AND FLUSH W/ EXIST FLOOR & WALL TO REMAIN. SEE DRAWING B8/AD-101 FOR PORTION
OF TERRAZZO COVE TO BE REMOVED.
R14 REMOVE WINDOW TREATMENTS AND ALL ASSOCIATED SUPPORTS AND HARDWARE.
R15 REMOVE DOOR & HARDWARE COMPLETELY. DOOR FRAME TO REMAIN. DOOR FRAME TO BE REPAIRED AND PREPARED TO BE PAINTED.
R16 REMOVE SSM WINDOW SILL AND PREP SURFACES TO RECEIVE NEW SILL.
SCALE: 1 1/2" = 1'-0"
B8
TERRAZZO COVE REMOVAL AT CORRIDOR WALLS
SCALE: NO SCALE
A8
REMOVAL KEYED NOTES
SCALE: NO SCALE
E8
GENERAL REMOVAL NOTES
SCALE: 1 1/2" = 1'-0"
F4
WINDOW SILL REMOVAL
SCALE: 1 1/2" = 1'-0"
E4
FLOOR PIPE PENETRATION INFILL
1 AMENDMENT #1 2020-11-30
UP
N O P Q R S T U
SCREENING
B434
SCREENING
B435
HAC
B407
CLEAN STORAGE
B433
CLEAN LINEN
B431
EXAM/OFFICE
B427
EXAM/OFFICE
B425
READING RM
B423
TLT
B426A
EXAM/OFFICE
B424
EXAM/OFFICE
B422
ECHO RM
B421
ECHO RM
B419
ECHO RM
B417
CHF INFUSION
B413
PUBLIC TLT
B432
SOILED HOLDING
B411
STRESS/ECHO TEST
B414
STRESS/ECHO TEST
B416
SCHEDULE
B408A
CASE MGR
B410
RECEPTION
B408
WAITING AREA
B406
ELEC
B418
/SEEE1 AS-101
OXYGEN
B415
STAFF WORK AREA
B426
ELEC
B409
CORRIDOR
B400C
CORRIDOR
B400A CORRIDOR
B400B
B435
B433
B432
B431
B407
EXG2
B409 B411 B413
B415
B417 B419 B421 B423
B426
B426A
B424B420B418B416B414
STAIR 5
4S5
F/E CLOS
B412
B412 B410B408
B408A
EXG3
EXG1
SCOPES
CR
CR CR
CR
AS-202
B1
A1
AS-200 A5
A3
A1
AS-200 C3C1
A8
AS-200D4
AS-200
D1
AS-200D2
AS-200C6
AS-201
E3
AS-201
E1
SHAFT 2
B424
1 A
7 A1 A
1 A
1 A
1 A 1 A
1 A
1 A
6 A
1 A 1 A
1 A
4 A
4 A4 A
1 A
5 A 5 A 5 A
1 C
1 A
2 A 2 A
2 A
2 A 2 A
2 A
1.1 A
5 A5 A
4 A
4 A
4 A
2 A
2 A
2 A
4 A
2 A
4 A
1 A
1 A 1 A 1 A
5 A1 A
2 A 2 A
2 A
2 A 2 A2 A
2 A
4 A
AS-200 D6
1' -1
3/
4"
'-1 0"
1/
8" 8'
-4
/8
5/
3/
6' -1
1/
4" 6'
-6
1' -3
/4
10'-2 1/4"2'-8 1/2"6'-2"3'-6"
5' -8
/4
9'
-0
/8
8' -1
7/
8" 8'
-7
3 1/8"9'-4 1/8" ±9'-9"9'-9"9'-9"2'-11 1/2"4'-7"4'-10 3/8"2'-0 3/4"4'-8"2'-1 3/8"7'-8 1/4"
3'-5 1/2" 5'-10 5/8"
1/
4"
'-7
3/
3'
-3
/4
3' -4
/8
1'
-9
8' -0
9'-9 1/8"9'-9 1/8"9'-9 1/8"9'-11 1/4"9'-11 1/4"9'-11 1/4"9'-8 1/4"8'-5"13'-3 1/4"8'-9"5'-6 1/4"
'-8
/8
8'
-4
/8
'-1
/4
ALIGN
'-7
/4
'-0
/4
3' -8
/8
19'-6"19'-6"19'-6"19'-1"13'-4"9'-8"13'-0"9'-2 1/4" ±
10'-5 1/4"
'-1
0" 9'
-7
/1 6"
'-1
7/
'-3
/4
122'-9 1/4"
8' -0
8 C 8 C 8 C 8 C8 C 8 C
2 A2 A2 A2 A
9 A
2 A2 A
7 A7 A
7 A
2' -0
3'
-0
3' -0
3'
-0
3' -6
1.1 A1.1 A
1.1 A
1.1 A1.1 A
B422
B425 B427
5 A
TYP
AS-400
B9
TYP
AS-400
B9
TYP
AS-400
B9
1 C
7 C
1 C
1 C
AS-100
F1
1' -5
/4
4 A
5 A
6 A
6 A
AS-100
F2
EXISTING LAUNDRY
CHUTE TO REMAIN
AS-100
F4
AS-101
F5
AS-200 D8
AS-200D6
AS-200D6
AS-200 D6
EXISTING 14"x18" DUCT
TO REMAIN SEE HVAC
EXISTING 10"x10" DUCT
TO REMAIN SEE HVAC
2'-6"
6 A 1 A
EXG4S5
1.1 A
1.1 A1.1 A
1.1 A1.1 A
1.1 A1.1 A
1.1 A
1 A
1 A
1 A
4 A
7 A
7 A7 A7 A 7 A7 A7 A
7 A
8 C8 C 7 A
8 C8 C
8 C
2 A
2 A
2 A
4 A
7 A7 A
7 A7 A
9'-2 1/4" ± 13'-0"
4A
SIM
SIM
SIMSIM
SIM
EXISTING 10"x10" DUCT
TO REMAIN SEE HVAC
1.1 A
7 A
7 A
7 A 7 A
1.1 A
1.1 A
7 A
2' -6
/8
EXAM/OFFICE
B420
7 A
7 A 7 A 7 A7 A
1 1
6 A
77 A
77 A
9A 9A
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITIONS AND ESTABLISHING THE
COMPATIBILITY OF ALL NEW WORK WITH THE EXISTING CONDITIONS.
2. ALL WORK IS BEING DONE ADJACENT TO, ABOVE, & BELOW OCCUPIED SPACE. GENERAL CONTRACTOR TO TAKE EVERY PRECAUTION TO ELIMINATE THE TRAVEL OF LIQUID, DUST AND DIRT FROM THE CONSTRUCTION AREA TO
THOSE SPACES.
3. GENERAL CONTRACTOR SHALL TAKE EVERY PRECAUTION TO MINIMIZE DISRUPTION WITH ADJACENT OCCUPIED SPACE. SCHEDULE AND SEQUENCING OF WORK TO BE COORDINATED WITH COR PRIOR TO BEGINNING WORK (SEE
DWG GC-101)
4. GENERAL CONTRACTOR SHALL PATCH ALL SURFACES TO REMAIN EFFECTED BY DEMOLITION OR REMOVAL OF EXISTING EQUIPMENT & CONSTRUCTION. NEW SURFACES TO BE FILLED, SANDED SMOOTH & FINISHED TO MATCH
ADJACENT SURFACE.
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROVISION AND CONTINUOUS MAINTENANCE OF ALL WORK FROM DAMAGE AND SHALL PROTECT THE OWNERS' PROPERTY FROM DAMAGE OR LOSS BY DUST, DIRT, WATER, THEFT, FIRE OR ANY OTHER PHYSICAL DAMAGE IN CONNECTION WITH THE CONTRACT.
6. MAINTAIN EXISTING UTILITIES INDICATED TO REMAIN. KEEP IN SERVICE, AND PROTECT AGAINST DAMAGE DURING ALL RENOVATION WORK. GENERAL CONTRACTOR TO COORDINATE CONSTRUCTION AROUND EXISTING EQUIPMENT, CONDUIT CABLING, ETC. WITH COR AS REQUIRED TO MAINTAIN CONTINUOUS OPERATION.
7. GENERAL CONTRACTOR SHALL COORDINATE EXACT LOCATION OF ALL NEW EQUIPMENT TO BE INSTALLED IN
CEILING WITH EXISTING MECHANICAL AND ELECTRICAL WORK TO REMAIN IN PLACE.
8. COMPLY WITH GOVERNING REGULATIONS PERTAINING TO ENVIRONMENTAL PROTECTION FOR POLLUTION
CONTROL & HAZARDOUS MATERIALS.
9. ALL PENETRATIONS IN RATED ASSEMBLIES SHALL BE SEALED WITH UL/FM APPROVED MATERIAL ASSEMBLIES AND
PROCEDURES ALL PENETRATIONS SHALL BE SEALED ON BOTH SIDES OF PENETRATION.
10. ALL DIMENSIONS ARE FROM FINISH FACE OF WALL TO FINISH FACE OF WALL.
11. LOCATE ALL NEW DOORS 4" FROM INSIDE CORNER UNLESS NOTED OTHERWISE.
12. CONTRACTOR TO PROVIDE NON COMBUSTIBLE BLOCKING AS REQUIRED BEHIND ALL WALLS FOR PROPER
INSTALLATION OF BUMPER GUARDS, WALL MOUNTED EQUIPMENT, WALL CABINETRY, ETC.
13. DRAWINGS SHALL NOT BE SCALED AS A BASIS FOR ESTABLISHING DIMENSIONS OR OTHER INFORMATION.
CONTRACTOR TO VERIFY ALL DIMENSIONS.
14. TEMPORARY PARTITIONS SHALL BE TO UNDERSIDE OF DECK, BE RATED 2HR, BE PROPERLY SEALED, AND THE SPACES UNDER CONSTRUCTION MUST HAVE CONTINUOUS NEGATIVE PRESSURE WITHIN WORK SITE.
15. ALL PARTITIONS TO BE TYPE 1A UNLESS NOTED OTHERWISE.
T
CONTROL JOINT EACH SIDE
METAL TRIM EACH SIDE
VINYL WALL COVERING
1 A1 A
5 A
EXISTING STEEL &
CONCRETE COLUMN
CORNER GUARDS AT ECHO
& STRESS ECHO ROOMS
8 C
8 C 8 C
8 C
7/
5/
8"1' -1
/1
6"
FURRING AS REQUIRED
CORNER GUARDS AT ECHO
& STRESS ECHO ROOMS
4 A
6 A
1 A
1' -3
1'
-3
2' -6
RUN RC-1 CHANNEL
CONTINUOUS ON THIS SIDE
30" WALL CABINET ABOVE 30" WALL CABINET ABOVE
O
EXISTING CONCRETE &
STEEL COLUMN
ø 2'-1 1/8"
5/
" PRE-ROLLED & FINISHED .090"
ALUMINUM
ANCHOR SIDE
(FASTENED TO STUD)
VERTICAL BUTT JOINT
MTL STUD ANCHORED TO
EXISTING COLUMN
RECESSED BASE AND CAPITAL
DROP SIDE (KEY SLOT
ATTACHMENT TO ANCHOR)
A Se rv ic e D i s a b le d Ve t e r an Owned
Sm a l l
B u s iness
SDVOSB
CVE
Location
Building Number
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0500-0016
o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t 6 o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
97 8654321
B
A
C
D
E
F
Revisions Date
ACTUAL
NORTH
Date
Project No.
Drawing NO.
Project Title
Checked Drawn
Drawing Title
Approved:
DESIGN RENOVATION
FOR 4B CARDIOLOGY
SYRACUSE VAMC, SYRACUSE, NY
Project Director
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE PROFESSIONAL ENGINEER.
Reviewed: Facility Manager
Reviewed: Facility Director
Reviewed:
Reviewed:
2020-10-26
528A7-18-726
BID DOCUMENTS
FULLY SPRINKLERED
KEYPLAN
SH AE
AREA
OF
WORK
UP
DN
Scientists | Engineers | Program Managers
Mabbett & Associates, Inc.
105 Central Street, Stoneham, MA 02180
T.
781-275-6050 www.mabbett.com AS-100
PARTIAL 4B FLOOR PLAN &
DETAILS
SCALE: 1/4" = 1'-0"
D1
PARTIAL 4B FLOOR PLAN - SOUTH
SCALE: NO SCALE
F7
GENERAL PLAN NOTES
SCALE: 1 1/2" = 1'-0"
F1
PLAN DETAIL @ TYP CORRIDOR COLUMN
KEYED NOTES-PLAN
NUMBER COMMENT
01 ALIGN NEW WALL WITH WINDOW JAMB UNLESS CHASE
CAN BE SMALLER.
02 COAT RACK, PROVIDE BLOCKING, SEE ELEVATIONS.
03 (3) 12" x 18" LOCKERS PER EQUIPMENT PLAN.
04 (8) 12" x 18" LOCKERS PER EQUIPMENT PLAN.
05 ALIGN 1/2" RC-1 CHANNELS. SEE DTL F2/AS-100
06 EXISTING WALL TO REMAIN.
07 COORDINATE FINAL WALL LOCATION WITH EXISTING
CONDITIONS IN FIELD. NEW WALL TO BE LOCATED AS
TIGHT TO EXISTING PIPES/DUCTWORK AS POSSIBLE.
COORD W/ C.O.R.
08 PAINT EXISTING DOOR.
SCALE: NO SCALE
F6
GENERAL PLAN NOTES
SCALE: 1 1/2" = 1'-0"
F2
PLAN DETAIL @ BACK TO BACK SINKS
SCALE: 1 1/2" = 1'-0"
F4
PLAN DETAIL @ ROUND COLUMN
N O P Q
EXAM/OFFICE
B444
EXAM/OFFICE
B442
EXAM/OFFICE
B440
EXAM/OFFICE
B438
EXAM/CHF
B436
SCREENING
B434
EXAM/OFFICE
B445
EXAM/OFFICE
B443
EXAM/OFFICE
B441
EXAM/OFFICE
B439
PACER
B437
SCREENING
B435
CLEAN STORAGE
B433
/SEED1 AS-100
PUBLIC TLT
B432
CORRIDOR
B400C
B445
B443
B441
B439
B437
B435
AS-202 D1C1
AS-201
A6
A8 C6
2 A
2 A2 A
5 A 1
2 A2 A
5 A
2 A
5 A
2 A
5 A 2 A
5 A 2 A
1 A
4 A
2 A
4 A 4 A
2 A
5 A
5 A
2 A
2 A 5 A
5 A
2 A
1 A
1' -3
/4
9'
-8
/8
9' -8
/8
9'
-8
/8
9' -8
/8
9'
-8
/8
9' -8
/8
3/
4"
6 1/4"13'-3 7/8" ±8'-4 7/8"13'-6 3/4" ±2 1/4"
1' -4
/8
9'
-8
/8
9' -8
9'
-8
/8
9' -8
/8
9'
-8
/8
9' -8
/8
3/
4"
'-0
/4
'-6
'-6
'-0
/4
13'-0" 9'-8" 13'-4"
36'-0"
8'-0"
2 A 2 A2 A22 A
2 A2 A
2 A 8 C8 C8 C 8 C8 C
8 C
8 C8 C8 C
8 C8 C8 C
2 A
2 A2 A 2 A2 A
2 A
2 A2 A
2 A
2 A2 A
7 A
2 A2 A
1.1 A1.1 A
1 A
8 A
1 A 2 A2 A
2 A
B444
TYP
AS-400
B9
TYP
AS-400
B9
B434
B436
B438
B440
B442
D6
AS-202
AS-200
F8
AS-200
F8
F5
AS-600
5 A
4A
7 A
6 A
2 A2 A
77 A
7 A7 A
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITIONS AND ESTABLISHING THE
COMPATIBILITY OF ALL NEW WORK WITH THE EXISTING CONDITIONS.
2. ALL WORK IS BEING DONE ADJACENT TO, ABOVE, & BELOW OCCUPIED SPACE. GENERAL CONTRACTOR TO TAKE EVERY PRECAUTION TO ELIMINATE THE TRAVEL OF LIQUID, DUST AND DIRT FROM THE CONSTRUCTION AREA TO
THOSE SPACES.
3. GENERAL CONTRACTOR SHALL TAKE EVERY PRECAUTION TO MINIMIZE DISRUPTION WITH ADJACENT OCCUPIED SPACE. SCHEDULE AND SEQUENCING OF WORK TO BE COORDINATED WITH COR PRIOR TO BEGINNING WORK (SEE
DWG GC-101)
4. GENERAL CONTRACTOR SHALL PATCH ALL SURFACES TO REMAIN EFFECTED BY DEMOLITION OR REMOVAL OF EXISTING EQUIPMENT & CONSTRUCTION. NEW SURFACES TO BE FILLED, SANDED SMOOTH & FINISHED TO MATCH
ADJACENT SURFACE.
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROVISION AND CONTINUOUS MAINTENANCE OF ALL WORK FROM DAMAGE AND SHALL PROTECT THE OWNERS' PROPERTY FROM DAMAGE OR LOSS BY DUST, DIRT, WATER, THEFT, FIRE OR ANY OTHER PHYSICAL DAMAGE IN CONNECTION WITH THE CONTRACT.
6. MAINTAIN EXISTING UTILITIES INDICATED TO REMAIN. KEEP IN SERVICE, AND PROTECT AGAINST DAMAGE DURING ALL RENOVATION WORK. GENERAL CONTRACTOR TO COORDINATE CONSTRUCTION AROUND EXISTING EQUIPMENT, CONDUIT CABLING, ETC. WITH COR AS REQUIRED TO MAINTAIN CONTINUOUS OPERATION.
7. GENERAL CONTRACTOR SHALL COORDINATE EXACT LOCATION OF ALL NEW EQUIPMENT TO BE INSTALLED IN
CEILING WITH EXISTING MECHANICAL AND ELECTRICAL WORK TO REMAIN IN PLACE.
8. COMPLY WITH GOVERNING REGULATIONS PERTAINING TO ENVIRONMENTAL PROTECTION FOR POLLUTION
CONTROL & HAZARDOUS MATERIALS.
9. ALL PENETRATIONS IN RATED ASSEMBLIES SHALL BE SEALED WITH UL/FM APPROVED MATERIAL ASSEMBLIES AND
PROCEDURES ALL PENETRATIONS SHALL BE SEALED ON BOTH SIDES OF PENETRATION.
10. ALL DIMENSIONS ARE FROM FINISH FACE OF WALL TO FINISH FACE OF WALL.
11. LOCATE ALL NEW DOORS 4" FROM INSIDE CORNER UNLESS NOTED OTHERWISE.
12. CONTRACTOR TO PROVIDE NON COMBUSTIBLE BLOCKING AS REQUIRED BEHIND ALL WALLS FOR PROPER
INSTALLATION OF BUMPER GUARDS, WALL MOUNTED EQUIPMENT, WALL CABINETRY, ETC.
13. DRAWINGS SHALL NOT BE SCALED AS A BASIS FOR ESTABLISHING DIMENSIONS OR OTHER INFORMATION.
CONTRACTOR TO VERIFY ALL DIMENSIONS.
14. TEMPORARY PARTITIONS SHALL BE TO UNDERSIDE OF DECK, BE RATED 2HR, BE PROPERLY SEALED, AND THE SPACES UNDER CONSTRUCTION MUST HAVE CONTINUOUS NEGATIVE PRESSURE WITHIN WORK SITE.
15. ALL PARTITIONS TO BE TYPE 1A UNLESS NOTED OTHERWISE.
6" 3'
-0
1' -6
1'
-6
3' -0
6"
2'-0" 9"
6 A
1X3 WOOD PAINTED TRIM. (EXTEND
FROM SILL TO UNDERSIDE OF
TRACK)
PROVIDE GWB "J" TRIM @ EDGE (TYP.)
CENTERLINE OF GLASS
SSM COUNTERTOP EXTENDS
THROUGH WINDOW OPENING.
SSM BACKSPLASH AND COUNTERTOP,
AS SCHEDULED.
6 A
1' -6
3'
-0
3' -0
3'
-0
1' -6
S S
M T
R A
N S
A C
T
IO
N C
O U
N T
E R
'-0
2 A
CONCEALED
COUNTER SUPPORT
BRACKET BELOW
LINE OF WOOD
WALL BELOW
GLASS DIVIDER PANEL
WITH CONCEALED
COUNTER SUPPORT
BRACKET BELOW
WALL PANEL WITH
1/4" Z CLIP SYSTEM
1 5/8" MTL STUDS
1X3 WOOD PAINTED TRIM. (EXTEND
FROM SILL TO UNDERSIDE OF
TRACK)
6"
COORD. WALL OPENING &
FRAMING WITH WINDOW MANUF.
F1
AS-200
3"3"
2"
2" GLASS SUPPORT ABOVE
9A
A Se rv ic e D i s a b le d Ve t e r an Owned
Sm a l l
B u s iness
SDVOSB
CVE
Location
Building Number
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0500-0016
o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t 6 o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
97 8654321
B
A
C
D
E
F
Revisions Date
ACTUAL
NORTH
Date
Project No.
Drawing NO.
Project Title
Checked Drawn
Drawing Title
Approved:
DESIGN RENOVATION
FOR 4B CARDIOLOGY
SYRACUSE VAMC, SYRACUSE, NY
Project Director
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE PROFESSIONAL ENGINEER.
Reviewed: Facility Manager
Reviewed: Facility Director
Reviewed:
Reviewed:
2020-10-26
528A7-18-726
BID DOCUMENTS
FULLY SPRINKLERED
KEYPLAN
SH AE
AREA
OF
WORK
UP
DN
Scientists | Engineers | Program Managers
Mabbett & Associates, Inc.
105 Central Street, Stoneham, MA 02180
T.
781-275-6050 www.mabbett.com AS-101
PARTIAL 4B FLOOR PLAN &
DETAILS
SCALE: 1/4" = 1'-0"
E1
PARTIAL 4B FLOOR PLAN - NORTH
SCALE: NO SCALE
F7
GENERAL PLAN NOTES
SCALE: 1 1/2" = 1'-0"
F5
PLAN DTL - RECEPTION WINDOW FRAMING
KEYED NOTES-PLAN
NUMBER COMMENT
01 ALIGN NEW WALL WITH WINDOW JAMB UNLESS CHASE
CAN BE SMALLER.
02 COAT RACK, PROVIDE BLOCKING, SEE ELEVATIONS.
03 (3) 12" x 18" LOCKERS PER EQUIPMENT PLAN.
04 (8) 12" x 18" LOCKERS PER EQUIPMENT PLAN.
05 ALIGN 1/2" RC-1 CHANNELS. SEE DTL F2/AS-100
06 EXISTING WALL TO REMAIN.
07 COORDINATE FINAL WALL LOCATION WITH EXISTING
CONDITIONS IN FIELD. NEW WALL TO BE LOCATED AS
TIGHT TO EXISTING PIPES/DUCTWORK AS POSSIBLE.
COORD W/ C.O.R.
08 PAINT EXISTING DOOR.
SCALE: NO SCALE
F1
GENERAL PLAN NOTES
4"
1'-0"
1"
2' -1
0" S
E E
E
LE
V A
T
IO
N
4"6"
S E
E E
LE
V
A T
IO
N
SSM-1 COUNTER SEE
FINISH SCHEDULE
SEE INTERIOR ELEVATION
AS TO FUNCTION OF BASE
CABINET SEE FINISH
SCHEDULE
PLYWOOD TOE
KICK W/
SCHEDULED BASE
FINISH
MELAMINE INTERIORS AND
ADJUSTABLE SHELVES
SCHEDULED
FLOORING
FIN FLOOR
+0"
+34"
AFF
UNDER CABINET LIGHT W/
CONCEALED WIRING (SEE
ELEC DWGS)
SEE ELEVATIONS
WALL CABINETS SEE
ELEVATIONS
+7'-1"
FILLER
S E
E E
LE
V
A T
IO
N
S
6"
1 / 4
1"
1/
2"
2' -3
M
IN 2'
-1
0"
FIN FLOOR
+0"
+34"
AFF
SCHEDULED FLOORING
1/2" THICK 4" HEIGHT SSM
SEE FINISH SCHEDULE
SST SINK
SSM-1 COUNTER
SEE FINISH SCHEDULE
VB
FIXED FRONT PANEL
FACE SCREWED IN
PLACE.
+7'-1"
UNDER CABINET LIGHT
(SEE ELEC DWGS)
WALL CABINETS SEE
ELEVATIONS
FILLER
PIPE COVERS ON
SUPPLIES AND DRAIN
RAKKS SYSTEM
BRACKETS
8' -0
VB-2
WALL PROTECTION WP-1
6" 2' -6
5' -0
CHAIR RAIL
INPRO 2700, OATMEAL
WALL PROTECTION WP-1
8' -0
3' -0
5' -0
VB-2
SSM-2 SSM-2
CHAIR RAIL
INPRO 2700, OATMEAL
A9
AS-400
B9
AS-400
C9
AS-400
GWB (PNT-2)
TYP.
TYP.
TYP.
WP-2
WP-1
WP-2
IMPACT RESISTANT
CORNER GUARD, PNT TO
MATCH PNT-2
FRY REGLET WCTOSC TRIM AT
OUTSIDE CORNERS OF WP-2
F1
AS-200
METAL REVEAL WALL BASE,
FRY REGLET MWCB75400
CLEAR ANNODIZED ALUM
(OR EQUIVALENT).
WOOD WALL
PANELS WD-1
7' -9
FLOATING TRANSACTION
COUNTER, SSM-1
3"
ACRYLIC PRIVACY PANEL, AR-1
WITH ALUMINUM CLIPS.
3/8" TEMPERED GLASS TRANSACTION
WINDOW. FRAMELESS GLASS IN
SYNCHRONIZED BI-PARTING POCKET
FRAME.
4' -2
2' -1 0"
FRY REGLET MILLWORK
CHANNEL - OUTSIDE CORNER
WITH RETURN KEYS.
MWCOSC75 CLEAR
ANNODIZED ALUMINUM (OR
EQUIVALENT).
FRY REGLET MILLWORK
CHANNEL WITH RETURN
KEYS- MWC7550 CLEAR
ANNODIZED ALUMINUM (OR
EQUIVALENT).
7"
CEILING MANUF. TRIM AT
SOFFIT.
OPEN
8' -0
5' -0
3' -0
WP-2
6" VINYL WALL BASE
WP-1
TV
METAL COLUMN
WRAP
MT-1
INPRO 2700 CHAIR RAIL
OATMEAL
B426
F6
AS-200
VB-1
W36W36W36W12
B15 B15 B15
(8) 12"x18" "Z"-LOCKERS
WITH SLOPED TOP
2' -6
2' -0
2' -6
1' -0
8' -0
TACK SURFACE
W36
30" UNDERCABINET
LIGHTING
30" UNDERCABINET
LIGHTING
EXG3
W30W24 1' -0
1' -6
2' -4
4" 2' -1 0"
8' -0
FIXED FRONT
SSM COUNTER
AND BACKSPLASH
UNDERCOUNTER
FRIDGE LOCATION
TACK SURFACE
W36W36W36
B15B15
COAT RACK
(3) 12"x18" "Z"-LOCKERS
WITH SLOPED TOP
F3
AS-200
MICROWAVE. VERIFY
SIZE WITH COR.
PROVIDE OUTLET.
30" UNDERCABINET
LIGHTING
SSM-1 COUNTER
AND BACKSPLASH
FIXED FRONT
PANEL
GWB (PT)
W18 W24
B42
2' -0
2' -6
1' -0
2' -6
8' -0
F5
AS-200
PTD
SD
SEE INTERIOR ELEVATION AS
TO FUNCTION OF Z LOCKER
TOE KICK W/ SCHEDULED
BASE FINISH
4"
SLOPED TOP
B414
W27W24
B27FIXED FRONT
PANELS
SSM-1 COUNTER
AND BACKSPLASH
PL LAM BASE AND
WALL CABINETS
TEE CABINET (VC)
GWB (PT)
VINYL WALL BASE
1' -0
1' -6
1' -0
1' -4
4" 2' -1 0"
8' -0
PTD
SD
24" UNDERCABINET
LIGHTING
W24W30
B30
FIXED FRONT
PANELS
SSM-1 COUNTER
AND BACKSPLASH
PL LAM BASE AND
WALL CABINETS
GWB (PNT-1)
VINYL WALL BASE
2' -1 0"
1' -8
1' -0
2' -6
8' -0
FINISHED END
PANEL
PTD
SD
3' -2
" WP-3
24" UNDERCABINET
LIGHTING
F1
AS-200
B36 B15 B15
GWB (PT)
VINYL WALL BASE
2' -1 0"
4' -2
1' -0
8' -0
36" LATERAL FILE
2'-0"3'-0"3'-0"3'-0"3'-8 7/8"
PRINTER &
COPIER
SSM-1 COUNTERTOP
AND 4" BACKSPLASH.
SSM-1 TRANSACTION
COUNTER THROUGH
WINDOW OPENING.
3/8" TEMPERED GLASS TRANSACTION
WINDOW. FRAMELESS GLASS IN
SYNCHRONIZED BI-PARTING POCKET
FRAME.
O
SSM-3 COUNTERTOP AND
BACKSPLASH SEE FINISH
SCHEDULE, ROUNDED
EDGE.
COUNTER SUPPORT
BRACKET 6'-0" O.C. MAX
VB-1
AT CENTER OF CURVED SURFACE
2'-9"
MILLWORK BEYOND
LED LIGHT FIXTURE, IN CEILING
MANIFOLD, ALUMINUM TRIM, &
HOUSING.
GLASS DIVIDER PANEL.
7" 2' -3
3/4" PLYWOOD
SUBSTRATE.
GLASS TRANSACTION WINDOW. BIPARTING
SYNCHRONIZED POCKET FRAME.
9" 4' -5
2' -6
4"
METAL 4" REVEAL BASE,
SHIM AS REQ'D.
1/4" Z-CLIP
WD-1 PANELS
5/8" GWB-PNT
5/8" GWB (TYP) PNT
GLASS GUIDE.
SSM TRANSACTION SURFACE
CONTINUES THROUGH
WINDOW OPENING.
3" 1 1/4" 3"
WOOD TRIM, PAINTED
DRYWALL TRIM
6" STUDS
2X BLOCKING
2" 4' -8
1"
1" OVERHANG
4"
1'-11 1/2"
6 A
SUSPENDED GWB
CEILING SYSTEM
MTL GLASS CLAMP
MTL GLASS CLAMP
GWB SUSPENDED SYSTEM
CEILING MANUF. TRIM
ACOUSTIC CEILING
1" 2"
W301' -0
2' -6
1' -8
2' -1 0"
8' -0
O A V S
5' -0
5'-0"
VERIFY LOCATION OF MED
GAS OUTLETS W/ C.O.R.
VB-1
SD GBP
SHDPTD
WP-3
SLOPED CABINET TOP
TO STRUCTURE ABOVE
SLOPE TOP WHERE INDICATED.
TO STRUCTURE ABOVE
SLOPE TOP WHERE INDICATED.
4'-0"3'-0"
5' -3
O A O A V S
VERIFY LOCATION OF MED
GAS OUTLETS W/ C.O.R.
VB-1
CG
WP-3
O A V S
GWB
(PNT-1)
VERIFY LOCATION OF MED
GAS OUTLETS W/ C.O.R.
VB-1
5' -0
3'-6"
SHD
GBP SD
CURTAIN
2'-4" 6"
2"
1'-0"
2"
4"
GWB (PNT-4)
GWB (PNT-2)
GWB (PNT-5)
W24
A Se rv ic e D i s a b le d Ve t e r an Owned
Sm a l l
B u s iness
SDVOSB
CVE
Location
Building Number
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0500-0016
o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t 6 o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
97 8654321
B
A
C
D
E
F
Revisions Date
Date
Project No.
Drawing NO.
Project Title
Checked Drawn
Drawing Title
Approved:
DESIGN RENOVATION
FOR 4B CARDIOLOGY
SYRACUSE VAMC, SYRACUSE, NY
Project Director
MILLER-REMICK LLCPROFESSIONAL ENGINEERPRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE PROFESSIONAL ENGINEER.
Reviewed: Facility Manager
Reviewed: Facility Director
Reviewed:
Reviewed:
2020-10-26
528A7-18-726
BID DOCUMENTS
FULLY SPRINKLERED
SH AE
Scientists | Engineers | Program Managers
Mabbett & Associates, Inc.
105 Central Street, Stoneham, MA 02180
T.
781-275-6050 www.mabbett.com AS-200
PARTIAL 4B INTERIOR
ELEVATIONS
SCALE: 3/8" = 1'-0"
A1
INTERIOR ELEVATION - WAITING AREA - EAST
SCALE: 3/8" = 1'-0"
A3
INTERIOR ELEVATION - WAITING AREA - SOUTH
SCALE: 3/8" = 1'-0"
A5
INTERIOR ELEVATION - WAITING AREA - WEST
SCALE: 3/8" = 1'-0"
A8
INTERIOR ELEVATION - WAITING AREA - NORTH
SCALE: 3/8" = 1'-0"
C1
INTERIOR ELEVATION - STAFF WORK AREA - EAST
SCALE: 3/8" = 1'-0"
C3
INTERIOR ELEVATION - STAFF WORK AREA - WEST
SCALE: 3/8" = 1'-0"
D4
INTERIOR ELEVATION - SOILED HOLDING
SCALE: 1" = 1'-0"
F6
TYPICAL LOCKER DETAIL
SCALE: 3/8" = 1'-0"
D1
INTERIOR ELEVATION - STRESS/ECHO TEST
SCALE: 3/8" = 1'-0"
D2
INTERIOR ELEVATION - STRESS/ECHO TEST 2
SCALE: 3/8" = 1'-0"
C6
INTERIOR ELEVATION - RECEPTION
SCALE: 1" = 1'-0"
F1
SECTON DETAIL @ RECEPTION DESK
SCALE: 3/8" = 1'-0"
D6
INTERIOR ELEVATION - ECHO ROOM
SCALE: 1" = 1'-0"
F3
SECTION DETAIL @ TYPICAL CABINET
SCALE: 1" = 1'-0"
F5
SECTION DETAIL @ TYPICAL SINK CABINET
SCALE: 3/8" = 1'-0"
D8
INTERIOR ELEVATION - STRESS ECHO TEST
SCALE: 3/8" = 1'-0"
F8
INTERIOR ELEVATION @ PACER & EXAM/CHF
SOAP
DISH
MIRROR
ACC-MOUNTHTS
(R E C O M M
3' -6
2' -6 M
IN
2' -1 0"
CL
*WHEN WALL SPACE PERMITS
SANITARY
NAPKIN
DISPOSAL
SIDE WALL GRAB BAR
FOR WATER CLOSET
REAR WALL GRAB BAR
FOR WATER CLOSET
PAPER TOWEL
DISPENSERS
NOTE: MOUNTING HEIGHTS MAY VARY DEPENDING ON REACH RANGE
CONDITION. FIXTURES AND ACCESSORIES SHOWN ARE FOR GRAPHIC
PURPOSES ONLY, REFER TO SPECS FOR ACTUAL PROJECT MODEL
NUMBERS.
12" MAX 42" MIN
54" MIN
16"-18"
24" MIN
36" MIN* CL
M
IN
M
IN
M A X
TOILET PAPER
DISPENSER LOCATION
O P E R A T
IN
G H W
M A X T O
HAND
DRYER
SANITARY
NAPKIN
DISPENSER
ROBE
HOOK
5' -0
2' -0
M
IN
39"-41"
BLOCKING
AREA
3' -4
S E A T H T
TPD
CT-2
CT-2
SSM-2
WT-2
CT-2 TO RETURN
TO WINDOWS
CT-2
CT-2
PTD
SD
HEATING
PANEL
B426A
CT-2
CT-2
TPD
CT-2
CT-2
PTD
CT-2
CT-2
SD
B432
CT-2
CT-2
TPD
CT-2
CT-2
PTD
SD
TPD
CT-2
CT-2
SCHLUTER
TILE TRIM
U
AS-201 C5A5
C3
A3
TLT
B426A
B426A
5 A
2 A
1.1 A1.1 A
1.1 A
1 A
TYP
AS-400
B9
1' -3
EXITING MASONRY
WALL
EXISTING DUCT TO
REMAIN SEE HVAC
HEATING PANEL
P
Q
AS-201
A1
C2
C1
A2
AS-600
F4
PUBLIC TLT
B432
B432
1.1 A
2 A
1.1 A
1.1 A
1 A 4 A
1 A
5 A1 A
1 A
1'-3"
HR-1
HR-1
CG-1 CG-1
HR-1
CG-1
4A
GWB
(PNT-1)
VB-1
PTD
SD
GBP
SHD
CURTAIN
2'-4" 6"
2"
1'-0"
2"
4"
GWB (PNT-4)
GWB (PNT-2)
GWB (PNT-5)
W30
SLOPED CABINET TOP
B442 GWB (PT)
VB-1
SHD
A9
AS-400
C9
AS-400
B9
AS-400
GWB (PT)
VB-1
A Se rv ic e D i s a b le d Ve t e r an Owned
Sm a l l
B u s iness
SDVOSB
CVE
Location
Building Number
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0500-0016
o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t 6 o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
97 8654321
B
A
C
D
E
F
Revisions Date
Date
Project No.
Drawing NO.
Project Title
Checked Drawn
Drawing Title
Approved:
DESIGN RENOVATION
FOR 4B CARDIOLOGY
SYRACUSE VAMC, SYRACUSE, NY
Project Director
MILLER-REMICK LLCPROFESSIONAL ENGINEERPRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE PROFESSIONAL ENGINEER.
Reviewed: Facility Manager
Reviewed: Facility Director
Reviewed:
Reviewed:
2020-10-26
528A7-18-726
BID DOCUMENTS
FULLY SPRINKLERED
SH AE
Scientists | Engineers | Program Managers
Mabbett & Associates, Inc.
105 Central Street, Stoneham, MA 02180
T.
781-275-6050 www.mabbett.com AS-201
PARTIAL 4B INTERIOR
ELEVATIONS
SCALE: 1/4" = 1'-0"
F1
TYPICAL ACCESSORY MOUNTING HEIGHTS
SCALE: 3/8" = 1'-0"
A3
INTERIOR ELEVATION -
STAFF TLT - NORTH
SCALE: 3/8" = 1'-0"
A5
INTERIOR ELEVATION -
STAFF TLT - EAST
SCALE: 3/8" = 1'-0"
C3
INTERIOR ELEVATION -
STAFF TLT - SOUTH
SCALE: 3/8" = 1'-0"
C5
INTERIOR ELEVATION -
STAFF TLT - WEST
SCALE: 3/8" = 1'-0"
A1
INTERIOR ELEVATION -
PUBLIC TLT - NORTH
SCALE: 3/8" = 1'-0"
A2
INTERIOR ELEVATION -
PUBLIC TLT - EAST
SCALE: 3/8" = 1'-0"
C1
INTERIOR ELEVATION -
PUBLIC TLT - SOUTH
SCALE: 3/8" = 1'-0"
C2
INTERIOR ELEVATION -
PUBLIC TLT - WEST
SCALE: 1/2" = 1'-0"
E3
ENLARGED FLOOR PLAN - STAFF TLT
SCALE: 1/2" = 1'-0"
E1
ENLARGED FLOOR PLAN - PUBLIC TLT
SCALE: 3/8" = 1'-0"
A6
INTERIOR ELEVATION - TYPICAL
EXAM/OFFICE - SINK WALL
SCALE: 3/8" = 1'-0"
A8
INTERIOR ELEVATION - TYPICAL
EXAM/OFFICE - DOOR WALL
SCALE: 3/8" = 1'-0"
C6
INTERIOR ELEVATION TYPICAL
EXAM/OFFICE - WINDOW WALL
N O P Q R S T
B408 B410 B412 B414 B416 B418 B420 B424
WAITING
CG-1
HANDRAIL
HR-1
WALL PROTECTION WP-1
5' -0
2' -8
4"
8' -0
GWB (PNT-1)
VB-2
ACCENT PANEL
FWC-1
2' -6
6"
MB-1
ACCENT PANEL
FWC-1
ACCENT PANEL
FWC-1
ACCENT PANEL
FWC-1
VB-2
VB-2
WALL PROTECTION WP-1
VB-2
WALL PROTECTION WP-1
VB-2
GWB (PNT-1)
WOOD WALL
PANELS. WD-1
SSM-3 TRANSACTION
COUNTER BEYOND
MT-1 ALUMINUM COLUMN
WRAP WITH INTEGRAL 6"
BASE AND CAPITAL.
B422
MB-1
S1 S1 S2 S1 S1 S1 S1 S1 S1 S1
TYP
/SEE F1 AS-100 /SEE F1 AS-100 /SEE F1 AS-100 /SEE F1 AS-100
NOPQRST
B423 B421 B419 B417 B415 B413 B411 B409 B407
5' -0
2' -6
6"
8' -0
CORRIDOR
CG-1 CG-1
WALL PROTECTION WP-1
GWB (PNT-1)
VB-1
B425B427
S1 S1 S1 S1 S1 S1 S1 S1 S1 S1
ACCENT PANEL
FWC-1
ACCENT PANEL
FWC-1
ACCENT PANEL
FWC-1
ACCENT PANEL
FWC-1 /SEE F1 AS-100 /SEE F1 AS-100 /SEE F1 AS-100 /SEE F1 AS-100
MED GAS
ZONE VAL
B445 B443 B441 B439 B437 B435 B433 B431
CG-1
WALL PROTECTION WP-1
GWB (PNT-1)
CORRIDOR
VB-2
6" 2' -6
5' -0
8' -0
HANDRAIL HR-1
ACCENT PANEL
FWC-1
ACCENT PANEL
FWC-1
ACCENT PANEL
FWC-1
ALUMINUM COLUMN WRAP
WITH INTEGRAL 6" BASE
AND CAPITAL BEYOND.
7'-9"
B/O GWB SOFFIT
3"
VB-2
WALL PROTECTION
WP-1
WALL PROTECTION WP-1
AS-600
F7
S1 S1 S1 S1
S2
S1 S1 S1 S1
FEC
D6
AS-202
4A
TYP
/SEE F1 AS-100 /SEE F1 AS-100 /SEE F1 AS-100
5 4 3 2
B432
CORRIDOR
CG-1
VB-2
5' -0
2' -6
6"
8' -0
B434 B436 B438 B440 B442 B444
GWB (PNT-1)
ACCENT PANEL
FWC-1
WALL PROTECTION WP-1 WALL PROTECTION WP-1
ACCENT PANEL
FWC-1
ACCENT PANEL
FWC-1
S3 S1 S1 S1 S1 S1 S1
CG-1 CG-1
F5
AS-600
4A
/SEE F1 AS-100 /SEE F1 AS-100 /SEE F1 AS-100
VB-2
HR-1
FEC CABINET
(SEMI-RECESSED)
6 A 1
(BEYOND)
A Se rv ic e D i s a b le d Ve t e r an Owned
Sm a l l
B u s iness
SDVOSB
CVE
Location
Building Number
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0500-0016
o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t 6 o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
97 8654321
B
A
C
D
E
F
Revisions Date
Date
Project No.
Drawing NO.
Project Title
Checked Drawn
Drawing Title
Approved:
DESIGN RENOVATION
FOR 4B CARDIOLOGY
SYRACUSE VAMC, SYRACUSE, NY
Project Director
MILLER-REMICK LLCPROFESSIONAL ENGINEERPRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE PROFESSIONAL ENGINEER.
Reviewed: Facility Manager
Reviewed: Facility Director
Reviewed:
Reviewed:
2020-10-26
528A7-18-726
BID DOCUMENTS
FULLY SPRINKLERED
SH AE
Scientists | Engineers | Program Managers
Mabbett & Associates, Inc.
105 Central Street, Stoneham, MA 02180
T.
781-275-6050 www.mabbett.com AS-202
PARTIAL 4B INTERIOR
ELEVATIONS
SCALE: 1/4" = 1'-0"
A1
INTERIOR ELEVATION - CORRIDOR B400B - SOUTH
SCALE: 1/4" = 1'-0"
B1
INTERIOR ELEVATION - CORRIDOR B400B - NORTH
SCALE: 1/4" = 1'-0"
C1
INTERIOR ELEVATION - CORRIDOR B400C - EAST
SCALE: 1/4" = 1'-0"
D1
INTERIOR ELEVATION - CORRIDOR B400C - WEST
SCALE: 1" = 1'-0"
D6
WALL SECTION @ PPE & FEC
1 AMENDMENT #1 2020-11-30
NOTE: SEE F1/AS-600 FOR SIGNAGE
CEILING HEIGHT
SEE PLANS
4 7/8" CEILING
SYSTEM AS
SCHEDULED
EXISTING BRICK
VENEER
FINISH BEAD & SEALANT,
TYP
EXISTING WINDOW
EXISTING CMU
BACKUP
NEW WINDOW TREATMENT
EXTEND CERAMIC TILE TO
FACE OF WINDOW IN
BATHROOM LOCATIONS
8'-3" VIF
1 5/8" METAL STUDS - 20 GA AT 16" OC
1 LAYER 5/8" GWB
FO EXIST WALL
1 1/2" RIGID INSUL
1/2"
EXISTING MASONY
WALL
EXISTING BRICK
VENEER
EXISTING WINDOW
CORNER BEAD
FO EXIST WALL
WDW APRON, BELOW W/ EASED EDGE
WDW SILL (SSM2)
3" MTL STUD
1 LAYER 5/8" GWB
1 1/2" RIGID INSUL
1 5/8" METAL STUDS - 20 GA AT 16" OC
EXISTING WALL PLASTER
SYSTEM TO REMIAN
EXTEND CERAMIC TILE TO FACE OF
WINDOW IN BATHROOM LOCATIONS
3" 31 / 2"
1/2"
EXISTING WINDOW
SEALANT, TYPICAL
MATERIAL FELT OVER
EXISTING SUBSTRATE
EXISTING BRICK
VENEER TO REMAIN
EXISTING MASONRY
WALL
EXISTING BRICK VENEER
AT JAMB BEYOND
1_
" SOLID SURFACE WINDOW
STOOL (SSM2) & SKIRT W/
EASED EDGES
EXISTING WINDOW TO
REMAIN
EXTEND CERAMIC TILE TO
FACE OF WINDOW IN
BATHROOM LOCATIONS
1 5/8" METAL STUDS - 20 GA AT
16" OC
1 1/2" RIGID INSUL
FO EXIST WALL
1 LAYER 5/8" GWB
F G1 2
J1
DOUBLE STUD
SEALANT BOTH
SIDES (TYP)
HM FRAME W/ MIN 3
ANCHORS PER JAMB
F O R T H R O A T D
IM
S E E P T N T Y P E S
CORNER PTN
WHERE
APPLICABLE
1/ 2"
1/ 2"
UNO
2" 2"
DOOR AS
SCHEDULED
1/2"1/2"
2"
FOR THROAT DIM
SEE PTN TYPES
H1
DOOR AS
SCHEDULED
T1
CL OF
DOOR
BUTT
JOINT
VCT, VT, OR
SV- SEE
FINISH PLAN
SVT, VTT, OR
SV- SEE
FINISH PLAN
1"
T2
CL OF
DOOR
TAPERED
MARBLE
THRESHOLD
CERAMIC TILE
WATERPROOF
MEMBRANE /
SETTING BED
PITCHED TO DRAIN
TO MATCH DOOR FRAME WIDTH PER SPEC.
2"
VCT, VT, OR
SV- SEE
FINISH PLAN
A Se rv ic e D i s a b le d Ve t e r an Owned
Sm a l l
B u s iness
SDVOSB
CVE
Location
Building Number
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0500-0016
o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t 6 o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
97 8654321
B
A
C
D
E
F
Revisions Date
Date
Project No.
Drawing NO.
Project Title
Checked Drawn
Drawing Title
Approved:
DESIGN RENOVATION
FOR 4B CARDIOLOGY
SYRACUSE VAMC, SYRACUSE, NY
Project Director
MILLER-REMICK LLCPROFESSIONAL ENGINEERPRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE PROFESSIONAL ENGINEER.
Reviewed: Facility Manager
Reviewed: Facility Director
Reviewed:
Reviewed:
2020-10-26
528A7-18-726
BID DOCUMENTS
FULLY SPRINKLERED
SH AE
Scientists | Engineers | Program Managers
Mabbett & Associates, Inc.
105 Central Street, Stoneham, MA 02180
T.
781-275-6050 www.mabbett.com AS-400
DOOR AND WINDOW
SCHEDULES & DETAILS
SCHEDULE-DOOR
DR NO
DOOR FRAME
RATING
(SEE SPEC)
HDW SET REMARKS DR NODR WIDTH DR HEIGHT P1 WIDTH P1 TYPE P2 WIDTH P2 TYPE MAT FINISH COLOR TYPE MAT FINISH COLOR HEAD JAMB THRESHOLD
B407 3'-6" 7'-0" 3'-6" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T1 - B407
B408 3'-6" 7'-0" 3'-6" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T1 - B408
B408A 3'-0" 7'-0" 3'-0" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T1 - B408A
B409 2'-6" 7'-0" 2'-6" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T1 - B409
B410 3'-6" 7'-0" 3'-6" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T1 - B410
B411 3'-6" 7'-0" 3'-6" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T1 45 MIN B411
B412 2'-0" 7'-0" 2'-0" G 0" WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T1 B412
B413 3'-6" 7'-0" 3'-6" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T1 - B413
B414 3'-6" 7'-0" 3'-6" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T1 - CARD READER ACCESS CONTROL B414
B415 6'-0" 7'-0" 3'-0" F 3'-0" F WD ACROVYN CLASSIC MAPLE 372 2 HM PNT H1 J1 T1 - B415
B416 3'-6" 7'-0" 3'-6" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T1 - CARD READER ACCESS CONTROL B416
B417 3'-6" 7'-0" 3'-6" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T1 - B417
B418 6'-0" 7'-0" 3'-0" F 3'-0" F WD ACROVYN CLASSIC MAPLE 372 2 HM PNT H1 J1 T1 - B418
B419 3'-6" 7'-0" 3'-6" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T1 - B419
B420 3'-6" 7'-0" 3'-6" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T1 - B420
B421 3'-6" 7'-0" 3'-6" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T1 - B421
B422 3'-6" 7'-0" 3'-6" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T1 - B422
B423 3'-6" 7'-0" 3'-6" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T1 - B423
B424 3'-6" 7'-0" 3'-6" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T1 - B424
B425 3'-6" 7'-0" 3'-6" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T1 - B425
B426 3'-0" 7'-0" 3'-0" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T1 - CARD READER ACCESS CONTROL B426
B426A 3'-0" 7'-0" 3'-0" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T2 - B426A
B427 3'-6" 7'-0" 3'-6" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T1 - B427
B431 3'-0" 7'-0" 3'-0" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T1 45 MIN B431
B432 3'-4" 7'-0" 3'-4" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T2 B432
B433 3'-6" 7'-0" 3'-6" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T1 45 MIN CARD READER ACCESS CONTROL B433
B434 3'-6" 7'-0" 3'-6" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T1 - B434
B435 3'-6" 7'-0" 3'-6" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T1 - B435
B436 3'-6" 7'-0" 3'-6" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T1 - B436
B437 3'-6" 7'-0" 3'-6" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T1 - B437
B438 3'-6" 7'-0" 3'-6" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T1 - B438
B439 3'-6" 7'-0" 3'-6" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T1 - B439
B440 3'-6" 7'-0" 3'-6" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T1 - B440
B441 3'-6" 7'-0" 3'-6" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T1 - B441
B442 3'-6" 7'-0" 3'-6" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T1 - B442
B443 3'-6" 7'-0" 3'-6" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T1 - B443
B444 3'-6" 7'-0" 3'-6" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T1 - B444
B445 3'-6" 7'-0" 3'-6" F 0" - WD ACROVYN CLASSIC MAPLE 372 1 HM PNT H1 J1 T1 - B445
EXG1 6'-0" 7'-0" 3'-0" F 3'-0" F - - - 2 - PNT - - - - EXG1
EXG2 2'-0" 2'-0" 2'-0" F 0" - - - - 1 - PNT - - - - LAUNDRY CHUTE DOOR EXG2
EXG3 2'-6" 7'-0" 2'-6" F 0" - - - - 1 - PNT - - - - PATCH/REPAIR & REPAINT. PROVIDE NEW SIGN & NEW KICKPLATE EXG3
EXG4S5 3'-4" 7'-0" 3'-4" F 0" - - - - 1 - PNT - - - - REPAINT EXG4S5
SCALE: NO SCALE
F1
FRAME TYPES & DOOR TYPES
SCALE: NO SCALE
B1
DOOR SCHEDULE
SCALE: NO SCALE
F3
HEAD & JAMB TYPES
SCALE: NO SCALE
D3
THRESHOLD TYPES
SCALE: 1 1/2" = 1'-0"
A9
WINDOW HEAD
SCALE: 1 1/2" = 1'-0"
B9
WINDOW JAMB
SCALE: 1 1/2" = 1'-0"
C9
WINDOW SILL
1 AMENDMENT #1 2020-11-30
NOT
USED
NOT
USED
1 1
SUSPENDED
ACOUSTIC CEILING
(2'X4')
SUSPENDED
ACOUSTIC CEILING
(2'X2')
GWB
SUPPLY
DIFFUSER
GRILLE
RETURN REGISTER
GRILLE
LINEAR SUPPLY
DIFFUSER
LINEAR RETURN
REGISTER
CAN LIGHT
FIXTURE
2X2 SURFACE MOUNT
LIGHT FIXTURE
2X2 RECESS MOUNT
LIGHT FIXTURE
EQ = EQUAL
SPACES (IN ROOM)
LAYOUT INSTRUCTIONS
START GRID AT
THIS WALL
GRID IN ROOM
WITH ARROW
ALIGNS WITH GRID
IN ROOM WITH DOT
FINISH
CEILING
HEIGHT
CEILING TAG
GRAPHIC SYMBOLS
AT 10' - 0" AFFCHILLED
BEAM
SPRINKLER
HEAD
CURTAIN TRACK
N O P Q R S T U
/SEEE1 AS-501
TLT
B426A
EXAM/OFFICE
B424
EXAM/OFFICE
B422
EXAM/OFFICE
B427
EXAM/OFFICE
B425
READING RM
B423
ELEC
B418
STRESS/ECHO TEST
B416
ECHO RM
B421
ECHO RM
B419
ECHO RM
B417
CHF INFUSION
B413
STRESS/ECHO TEST
B414
SOILED HOLDING
B411
PUBLIC TLT
B432
SCREENING
B434
SCREENING
B435
CLEAN STORAGE
B433
CLEAN LINEN
B431
HAC
B407
CASE MGR
B410
SCHEDULE
B408A
RECEPTION
B408WAITING AREA
B406
STAFF WORK AREA
B426
STAIR 5
4S5
CORRIDOR
B400B
SHAFT 2
B424
OXYGEN
B415
C L E Q
E Q
CL
EQ EQ
CL
EQ EQ
EQ
EQ
EQ
E Q
E Q
E Q
E Q
E Q
E Q
E Q
F1
AS-200
D-107
D-108
CHILLED BEAM
5 1/4"2'-5 1/2"2'-3 3/4"
2' -3
/2
3/ 4"
1' -6 /4
4A
AT 8'-0" AFF
AT 9'-0" AFF
AT 8'-0" AFF
AT 8'-0" AFF
AT 8'-0" AFF
AT 8'-0" AFF
AT 8'-0" AFF 604
AT 8'-0" AFF
AT 8'-0" AFF
AT 8'-0" AFF
AT 8'-0" AFF
AT 8'-0" AFF
AT 8'-0" AFF
AT 8'-0" AFF
AT 8'-0" AFF
AT 8'-0" AFF
AT 8'-0" AFF
AT 8'-0" AFF
AT 8'-0" AFF
AT 8'-0" AFF 604
AT 8'-0" AFF
AT 8'-0" AFF
AT 8'-0" AFF
AT 8'-0" AFF
C8
AS-501
BULKHEAD
A Se rv ic e D i s a b le d Ve t e r an Owned
Sm a l l
B u s iness
SDVOSB
CVE
Location
Building Number
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0500-0016
o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t 6 o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
97 8654321
B
A
C
D
E
F
Revisions Date
ACTUAL
NORTH
Date
Project No.
Drawing NO.
Project Title
Checked Drawn
Drawing Title
Approved:
DESIGN RENOVATION
FOR 4B CARDIOLOGY
SYRACUSE VAMC, SYRACUSE, NY
Project Director
MILLER-REMICK LLCPROFESSIONAL ENGINEERPRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE PROFESSIONAL ENGINEER.
Reviewed: Facility Manager
Reviewed: Facility Director
Reviewed:
Reviewed:
2020-10-26
528A7-18-726
BID DOCUMENTS
FULLY SPRINKLERED
KEYPLAN
SH AE
AREA
OF
WORK
UP
DN
Scientists | Engineers | Program Managers
Mabbett & Associates, Inc.
105 Central Street, Stoneham, MA 02180
T.
781-275-6050 www.mabbett.com AS-500
PARTIAL 4B REFLECTED
CEILING PLAN & DETAILS
SCALE: 1/4" = 1'-0"
D1
PARTIAL 4B REFLECTED CEILING PLAN - SOUTH
SCALE: NO SCALE
F6
CEILING LEGEND
9"
9"
2"
STAIR #
BRAILLE
LEVEL 5
EXIT
STAIR DOWN
BRAILLE
Keep Door Closed
TYPOGRAPHY
HELVETICA MEDIUM
5' -0
A
F F
DOOR FRAME
BACKGROUND COLOR AS
SELECTED BY VAMC COR
ITEM FINISH CODE MANUFACTURER/PATTERN COLOR NUMBER COLOR REMARKS
FLOOR FINISHES
CERAMIC TILE CT-1 AMERICAN OLEAN, THEORETICAL - 2" X 2"
ALL TOILET ROOM FLOORS. GROUT: FLEXTILE,
CHARCOAL
VTT-1 FLOORAZZO CORRIDOR, WAITING
VTT-2 CORRIDOR ACCENT
VTT-3 CORRIDOR ACCENT
SHEET VINYL SV-1 MANNINGTON BIOSPEC W/ 6" INTEGRAL BASE (INT-1)
SOILED, CLEAN UTILITY/HSKPING CLOSET, & CLEAN
SUPPLY
BASE TYPES
VINYL BASE VB-1 JOHNSONITE 6" H COVE BASE EXAM TREATMENT, STAFF ROOMS
VB-2 JOHNSONITE 6" H MILLWORKS REVEAL BASE WAITING & PUBLIC CORRIDORS
INT-1
6" INTEGRAL BASE TO MATCH FLOORING SV-1 W/
METAL CAP
WALL FINISHES
CERAMIC TILE CT-2 DALTILE, AMBASSADOR, 12"X24"
INTERIOR PAINT* PNT-1 PITTSBURGH PAINTS
GENERAL WALL PAINT, DR FR & PNTD DR (SEMI-GLOSS)
PNT-2 WAITING ROOM AND EXAM ACCENT
PNT-3 GWB CEILINGS & BULKHEADS
CEILING FINISHES
ACOUSTICAL CEILING ACT-1 ARMSTRONG/HEALTHZONE ULTIMA LAY-IN 24"X24" WITH
15/16" GRID (WHITE)
MISCELLANEOUS FINISHES
CUBICLE CURTAINS CC-1A INPRO-SHIELD
CORNER GUARDS CG-1 INPRO 2"/FULL HEIGHT
LOCATION: OUTSIDE CORNERS ALL PATIENT CORRIDORS
AND CLINICAL SUPPORT AREAS.
HANDRAILS HR-1
RIGID WALL PROTECTION WP-1 INPRO WALL COVERING. RIGID SHEET .040" THICK. 0239
PATIENT CORRIDOR BELOW HANDRAIL, SOILED
HOLDING, HAC, & CLEAN LINEN.
PLASTIC LAMINATE
PL-1 WILSONART
7981K-12
SOFTGRAIN
FINISH
SOLID SURFACING MATERIALS
SSM-1
CORIAN
SSM-2
CORIAN
WINDOW SILLS
TACKABLE SURFACES TS-1 CARNEGIE - XOREL
TUDOR
ALL VERTICAL JTS TO BE BUTT JTS W/ FACTORY
COLOR MATCHED SLNT.
WT-2 DUSTED CRYSTAL TOILET ROOM B425A
*ALL PAINT TO BE PITTSBURGH PAINT MATCH COLORS INDICATED IN LEGEND.
PAINT FINISH NOTE: DOORS AND FRAMES TO BE SEMI GLOSS FINISH
INPRO CORP. 3510FVSD
ALL TOILETS ROOMS, INSTALL VERTICAL STACKED FULL
HEIGHT BOND W SCHLUTER @ OUTSIDE CORNERS
EP TOILET ROOM CEILINGS, SOILED ROOM & HSKPING CLOSETS
GENERAL CEILING TILE
ACOUSTICAL CEILING ACT-2 ARMSTRONG/CLEAN ROOM ULTIMA LAY-IN 24"X24" WITH
15/16" GRID (WHITE) SOILED, CLEAN SUPPLY & HSKPING CLOSETS, & LINEN
TYPICAL CASEWORK
3M CRYSTAL GLASS
6603 36
CORRIDORS
TYPICAL COUNTERS
PITTSBURGH PAINTS
PITTSBURGH PAINTS
PITTSBURGH PAINTS (EPOXY PAINT)
FLOORAZZO
FLOORAZZO
DASH
SAND DUNE
SST BUMPER RAIL W/
ROUND VINYL HANDRAIL IN
SUGAR MAPLE
0548-VELVET FINISH
OATMEAL
LANDMARK WOOD
EVEREST
CARBON CONCRETE
WHITE
MATCH WP-1
(SLATE 0237)
WHITE
FIBERGLASS REINFORCED PANELS FRP-1 MARLITE PANELS
HAC
PANELS
M360 OUTSIDE CORNER
M350 INSIDE CORNER
M365 DIVISION
M370 EDGE
TRIMS - P-140 IVORY
PNT-4 EXAM ROOM ACCENT 1PITTSBURGH PAINTS
WD-1 PARKLEX INTERIOR DRY ACOUSTIC PANELS WALNUT WAITING - Z-CLIP INSTALLATION
SOILED, CLEAN UTILITY/HSKPING CLOSET, LINENS, & CLEAN
SUPPLY
WOOD WALL PANEL
VTT-4 FLOORAZZO WAITING ACCENT
SVT-1 PATCRAFT, CREATIVE CODE 1476VSOLID VINYL TILE EXAM TREATMENT, RECEPTION, STAFF AREAS
TH96 CREATIVE GRAY
WANDERLUST WHITE AM36,
POLISH…