This pre-solicitation notice provides details for an upcoming solicitation to upgrade ventilation systems in Building 76 at the VA Medical Center in Bath, New York. The project scope includes installing a conditioned, central air distribution system on the 4th floor and portions of the 5th floor, constructing a chase way for future ductwork, and cross connecting certain piping. The solicitation will be posted on October 7, 2020. The NAICS code is 238220 and the small business size standard is $16.5 million. The contract value is estimated between $1-5 million. The solicitation will require a 20% bid bond and winning bidder must provide performance and payment bonds. The procurement is reserved for Service-Disabled Veteran-Owned Small Businesses.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PATH OF CONSTRUCTION SUPPLEMENTAL

ASBESTOS-CONTAINING MATERIALS SURVEY

B76-BATH VAMC

76 VETERANS AVENUE

BATH, NEW YORK 14810

ECS PROJECT NO. 47:9550-A

FOR: WATSON ENGINEERING, PC

JUNE 4, 2020

June 4, 2020

Mr. John Evangelista Watson Engineering, PC 1112 State Route 434 Owego, New York 13827 john@watson-engineer.com

ECS Project No. 47:9550-A

Reference: Path of Construction Supplemental Asbestos-Containing Materials Survey, B76-Bath VAMC, 76 Veterans Avenue, Bath, New York

Dear Mr. Evangelista:

ECS Mid-Atlantic, LLC (ECS) is pleased to provide Watson Engineering, PC with the results of the above referenced Path of Construction Supplemental Asbestos-Containing Materials Survey performed at B76-Bath VAMC located at 76 Veterans Avenue in Bath, New York. This report summarizes our observations, analytical results, findings, and recommendations related to the work performed. The work described in this report was performed by ECS in general accordance with the Scope of Services described in ECS Proposal Number 47:13535-EP and the terms and conditions of the agreement authorizing those services.

ECS appreciates this opportunity to provide Watson Engineering, PC with our services. If we can be of further assistance to you, please do not hesitate to contact us.

Sincerely, ECS Mid-Atlantic, LLC

Ryan Szoldatits Michael K. Smith, CSP Environmental Staff Project Manager Environmental Principal RSzoldatits@ecslimited.com MKSmith@ecslimited.com

412-206-1555 NY Asbestos Inspector CERT# 19-11873

717-767-4788

145 Lake Drive, Suite 102, Wexford, Pennsylvania 15090 • T: 412-206-1555 • F: 412-927-1273 • ecslimited.com

EXECUTIVE SUMMARY

The subject property is improved with a Health Care Center operated by the US Department of Veteran Affairs. The VA Bath Health Care building consists of a seven-floor, 211,366 square foot structure located at 76 Veterans Avenue in Bath, New York. ECS understands that the subject property building is scheduled for renovations. Based on the Mechanical Plans prepared by Watson Engineering and dated December 5, 2019; the path of construction includes the 4th floor with minor demolition proposed on the 3rd, 5th, and 7th floors.

The purpose of this Path of Construction Supplemental Asbestos-Containing Materials Survey is to evaluate if asbestos-containing materials (ACMs) may be present within portions of the building to be renovated. Reportedly the proposed renovations include steam and ventilation system upgrades that will impact .the attic, 5th floor, 4th floor, and 3rd floor of the structure.

Based on the laboratory analysis of the bulk samples collected during the supplemental survey, the following materials were reported to contain asbestos:

• White pipe wrap/mudded elbow sampled in Room 314;

• Black tar coating on fiberglass HVAC duct (trace) sampled in Room 434;

• Black tar coating on fiberglass HVAC duct (trace) sampled on the 6th floor;

• Cloth HVAC duct vibration dampener sampled on the 6th floor;

• Black tar in cork pipe wrap insulation sampled in Attic; and

• Insulation on pipe hangars 6th floor (presumed).

Previously sampled materials reported to contain asbestos include the following:

• White Ceiling Plaster Skim Coat (trace) presumed throughout;

• Tan Ceiling Plaster Surface Material presumed throughout;

• Gray ceramic floor tile grout on green floor tile (trace) sampled in Rooms 410 & 421;

• Gray ceramic floor tile grout on green backsplash tile and brown mastic (trace) sampled in

Rooms 410 & 421;

• 1' x 1' Brown and white vinyl floor tiles and black mastic sampled on 4th floor rooms and under carpeted areas;

• Brown cove base mastic (trace) sampled in Room 411;

• Brown ceiling glue dot above drop ceiling sampled on the 4th floor;

• White joint compound associated with drywall sampled on the 6th floor;

• Yellow/green carpet mastic (trace) sampled in Room 447;

• Yellow mastic on light blue backsplash tile (trace) sampled in 4th floor vacant bathroom;

• Yellow/black mastic associated with 1' x 1' Gray vinyl floor tile sampled inRoom 429;

• 1' x 1' Brown marbled pattern vinyl floor tile (mastic presumed) sampled in Room 438;

• 1' x 1' Tan/brown speckle pattern vinyl floor tile (mastic presumed) sampled in Room 434;

• Black/brown mastic associated with white/pink vinyl floor tile (trace) sampled in Rooms 433 and 433A;

• 1' x 1' Green vinyl floor tile (mastic presumed) sampled in Room 467;

• 1' x 1' Olive vinyl floor tile (mastic presumed) sampled in Room 467;

• 1' x 1' White/green marbled pattern vinyl floor tile (mastic presumed) sampled in Room 444;

ECS Project # 47:9550-A

• 1' x 1' Black/white marbled pattern vinyl floor tile (mastic presumed) sampled in Room 456B;

• 1' x 1' Butterscotch color vinyl floor tile (mastic presumed) sampled in Room 407;

• 1' x 1' Blue marbled pattern vinyl floor tile (mastic presumed) sampled in Room 457;

• Black/silver pipe wrap 6th floor duct work sampled on the 6th Floor;

• Black HVAC wrap (labeled as asbestos ) observed on the 6th Floor; and

• White pipe wrap (labeled as asbestos) observed in the attic.

ECS recommends where a material type has been identified as asbestos-containing that other materials with similar color, texture, age and size throughout the building’s interior and exterior be assumed to contain asbestos.

The executive summary is an integral portion of this report, however, ECS recommends the report be read in its entirety.

PAGETABLE OF CONTENTS

1.0 SITE DESCRIPTION

2.0 PURPOSE

3.0 METHODOLOGY

3.1 Asbestos-Containing Materials

4.0 RESULTS

4.1 Asbestos-Containing Materials

4.2 Suspect or Assumed Asbestos-Containing Materials

5.0 RECOMMENDATIONS AND REGULATORY REQUIREMENTS

5.1 Asbestos-Containing Materials

6.0 LIMITATIONS

TABLE OF APPENDICES

Appendix I: Asbestos Sample Location Diagram

Appendix II: Asbestos Extent Drawings

Appendix III: Site Photographs

Appendix IV: Asbestos Bulk Sample Results

Appendix V: Certifications/Licenses

Appendix VI: Previous Reports

1.0 SITE DESCRIPTION

The subject property is improved with a Health Care Center operated by the department of Veteran Affairs. The VA Bath Health Care building consists of a seven-floor, 211,366 square foot structure located at 76 Veterans Avenue in Bath, New York. ECS understands that steam and ventilation upgrades are scheduled for portions of the building. Based on the Mechanical Plans prepared by Watson Engineering and dated December 5, 2019;, the path of construction includes the 4th floor with minor demolition proposed on the 3rd, 5th, and 7th floors. Demolition plans were provided indicating the path of construction.

2.0 PURPOSE

The purpose of this Path of Construction Supplemental Asbestos-Containing Materials Survey is to evaluate if asbestos-containing materials (ACMs) may be present within portions of the building to be renovated. Reportedly the proposed renovations include steam and ventilation systems.that will impact the 4th floor and portions ofthe attic, 5th floor, and 3rd floor of the structure.

3.0 METHODOLOGY

ECS performed the authorized Scope of Services in general accordance with our proposal, standard industry practice(s) and methods specified by regulation(s) for the identification of Asbestos-Containing Materials (ACMs).

3.1 Asbestos-Containing Materials

The non-destructive asbestos survey was performed by asbestos inspectors who have received EPA accredited training and is licensed by the State of New York. Samples of suspect ACMs were collected utilizing hand tools and placed into individual, labeled plastic bags. Unique bulk suspect ACM samples were submitted to Eurofin/CEI in Cary, North Carolina and analyzed utilizing the Polarized Light Microscopy (PLM) method in accordance with the New York State Environmental Laboratory Approval Program (ELAP) method 198.1 for Determination of Asbestos in Friable Bulk Building Materials.

Non-friable samples were analyzed via PLM by NYS ELAP Method 198.6 for non-friable organically bound (NOB) materials. NOB materials (i.e., floor tile, mastic, roofing tar) must undergo transmission electron microscopy (TEM) analysis if the result of PLM/NOB (198.6) analysis is negative before being considered non-ACM. Therefore, NOB samples that were negative (including non-detect) via PLM were also analyzed for TEM by NYS ELAP Method 198.4. Materials consisting of additional layers were analyzed separately.

Eurofin/CEI is listed as an accredited laboratory by the National Voluntary Laboratory Accreditation Plan (NVLAP) managed by the National Institute of Standards and Technology (NIST) for bulk sample analysis by currently approved EPA methodology by PLM and TEM. Eurofin/CEI is listed as an accredited laboratory by the NY ELAP.

During the survey, ECS attempted to identify suspect ACMs in readily accessible areas. However, due to the destructive means required to identify some materials, certain areas were deemed inaccessible (i.e. behind walls or sub grade materials) and were not surveyed for suspect ACMs. Unidentified suspect ACMs may be located in these and/or other inaccessible areas.

June 4, 2020

Samples were collected in general accordance with EPA Standard 40 CFR 763 Subpart E, Asbestos Hazard Emergency Response Act (AHERA) and OSHA Standard 29 CFR 1926.1101 Inspection Protocol.

Multiple samples of each unique material were submitted. Samples were analyzed using “Positive Stop” methodology. If one sample of a homogeneous material is reported to contain asbestos, the remaining samples of that material are not analyzed. EPA regulations stipulate that if one sample contains asbestos the entire quantity of that material contains asbestos, regardless of additional analysis.

4.0 RESULTS

The following is a summary of laboratory results, findings and observations.

4.1 Asbestos-Containing Materials

In total, 85 bulk samples from 25 homogeneous areas were submitted to the laboratory of which 147 layers were analyzed.

An Asbestos-Containing Material (ACM) is defined as any material containing more than one percent (>1%) asbestos as determined using the method specified in Appendix E, Subpart E, 40 CFR Part 763, Section 1, PLM. Materials are categorized by the U.S. EPA in the following categories:

• Friable ACMs are defined as any ACM that, when dry, can be crumbled, pulverized or reduced to powder by hand pressure. Non-friable ACMs are defined as any ACM that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.

• Category I non-friable ACM are listed as following: packings, gaskets, resilient floor coverings, and asphalt roofing products containing more than one percent (>1%) asbestos.

• Category II non-friable ACM are listed as any material, excluding Category I non-friable ACM, containing more than one percent (>1%) asbestos.

Regulated Asbestos Containing Materials (RACM) are friable ACM or non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading or has crumbled, been pulverized, or reduced to powder in the course of renovation and/or demolition operations.

Eurofins CEI submitted a signed final laboratory report to ECS on May 29, 2020. Three of the bulk samples submitted for analysis were reported to contain asbestos in detectable concentrations.

These materials are summarized below. A complete list of the sampled materials submitted for analysis and sample locations are located in the Appendix of this report. Additional details regarding the overall locations of the materials identified as asbestos-containing are provided further in the report. Photographs of collected samples reported as asbestos-containing are also located in the Appendix of this report.

June 4, 2020

Summary of Asbestos-Containing Materials Identified

Sample ID Location Material Description

Analytical Results Category

4, 5, 6 Room 314 White pipe wrap/mudded elbow

14% Asbestos Friable

37 Room 434 Air handler

Black tar coating on fiberglass HVAC Duct

Trace (0.11%) Asbestos

N/A

66 6th Floor

HVAC

Black tar coating on fiberglass HVAC Duct

Trace (0.07%) Asbestos

N/A

74, 75 6th Floor

HVAC

Cloth dampener on HVAC Duct

67% Asbestos Cat II Non-Friable

80 Cold water pipe in Attic

Black tar in cork pipe wrap insulation

3.8% Asbestos Cat II Non-Friable

- Pipe hangars 6th Floor

Mag Insulation Friable

Based on the laboratory analysis of the bulk samples collected during the supplemental survey, the following materials were reported to contain asbestos:

• White pipe wrap/mudded elbow sampled in Room 314;

• Black tar coating on fiberglass HVAC duct (trace) sampled in Room 434;

• Black tar coating on fiberglass HVAC duct (trace) sampled on the 6th floor;

• Cloth vibration dampener on HVAC sampled on the 6th floor HVAC;

• Black tar in cork pipe wrap insulation sampled in Attic; and

• Insulation on pipe hangars 6th floor (presumed).

Previously sampled materials reported to contain asbestos include the following:

• White Ceiling Plaster Skim Coat (trace) presumed throughout;

• Tan Ceiling Plaster Surface Material presumed throughout;

• Gray ceramic floor tile grout on green floor tile (trace) sampled in Rooms 410 & 421;

• Gray ceramic floor tile grout on green backsplash tile and brown mastic (trace) sampled in

Rooms 410 & 421;

• 1' x 1' Brown and white vinyl floor tiles and black mastic sampled on 4th floor rooms and under carpeted areas;

• Brown cove base mastic (trace) sampled in Room 411;

• Brown ceiling glue dot above drop ceiling sampled on the 4th floor;

• White drywall joint compound associated with drywall sampled on the 6th floor;

• Yellow/green carpet mastic (trace) sampled in Room 447;

• Yellow mastic on light blue backsplash tile (trace) sampled in 4th floor vacant bathroom;

• Yellow/black mastic associated with 1' x 1' Gray vinyl floor tile sampled in Room 429;

• 1' x 1' Brown marbled pattern vinyl floor tile (mastic presumed) sampled in Room 438;

June 4, 2020

• 1' x 1' Tan/brown speckle pattern vinyl floor tile (mastic assumed) sampled in Room 434;

• Black/brown mastic associated with white/pink vinyl floor tile (trace) sampled in Rooms 433 and & 433A;

• 1' x 1' Green vinyl floor tile (mastic assumed) sampled in Room 467;

• 1' x 1' Olive vinyl floor tile (mastic assumed) sampled in Room 467;

• 1' x 1' White/green marbled pattern vinyl floor tile (mastic assumed) sampled in Room 444;

• 1' x 1' Black/white marbled pattern vinyl floor tile (mastic assumed) sampled in Room 456B;

• 1' x 1' Butterscotch color vinyl floor tile (mastic assumed) sampled in Room 407;

• 1' x 1' Blue marbled pattern vinyl floor tile (mastic assumed) sampled in Room 457;

• Black/silver pipe wrap 6th floor duct work sampled on the 6th Floor;

• Black HVAC wrap (labeled as with asbestos sticker (presumed) observed on the 6th Floor;

and

• White pipe wrap (labeled as with asbestos sticker (presumed) observed in the attic.

The previous survey identified white ceiling plaster skim coat (trace) and tan plaster surfacing as ACMs. ECS attempted to delineate the extent of the asbestos ceiling plaster; however, the additional plaster samples (8 ceiling and 8 wall plaster samples) were all non-detect for asbestos. The tan surfacing material identified as an extra layer in a sample collected from from 414A, was not observed at the time of our supplemental sampling. ECS collected another sample of the ceiling plaster in the same general location (sample 63) and only two layers (gray base coat and white skim coat) were identified (both non-detect). ECS believes that the tan plaster surfacing may have been contamination from the ceiling tile glue dots associated with the ceiling systems.

ECS collected 8 additional samples of drywall and joint compound to delineate the previously identified asbestos-containing joint compound. Drywall finishes were limited and the previous samples were collected on the 6th Floor. The supplemental of drywall and joint compound were collected from the 4th floor, within the path of construction. In summary, none of the additional samples contained detectable concentrations of asbestos. It appears that the asbestos-containing joint compound is present on the 6th floor, but samples collected from the 4th floor were non-detect for asbestos.

4.2 Suspect or Assumed Asbestos-Containing Materials

Due to the inaccessibility or the destructive means that asbestos sampling requires, additional suspect ACMs may remain within the building hidden behind inaccessible areas that include, but are not limited to, sub-grade walls, structural members, topping slabs, sub-grade sealants, flooring located below underlayments, areas behind exterior walls, pipe trenches, and subsurface utilities, etc. These areas were deemed inaccessible and were not assessed. Fire doors were observed throughout the path of construction and assumed to be asbestos-containing. ECS also observed suspect asbestos in the pipe hangar saddles on the 6th floor. The suspect insulation was not accessible and should be presumed to be ACM.

If these materials are discovered during construction activities, they should be presumed to contain asbestos and be treated as ACMs or be sampled immediately upon discovery and prior to disturbance for asbestos content by a licensed asbestos inspector in accordance with 29 CFR 1926.1101 and NY Department of Labor Code Rule 56.

June 4, 2020

5.0 RECOMMENDATIONS AND REGULATORY REQUIREMENTS

Based on our understanding of the purpose of the Path of Construction Supplemental Asbestos-Containing Materials Survey, the results of laboratory analysis, and our findings and observations, ECS presents the following recommendations.

5.1 Asbestos-Containing Materials

A trace amount of asbestos (≤1%) was detected in the bulk sample(s) of black tar coating on fiberglass HVAC (Samples 37, & 66) analyzed by the laboratory. The ceiling plaster sampled on the 4th floor was previously identified as containing trace asbestos. As part of the supplemental survey, ECS collected additional plaster samples; all of which were non-detect. The previous survey identified white ceiling plaster skim coat (trace) and tan plaster surfacing as ACMs. ECS attempted to delineate the extent of the asbestos ceiling plaster; however, the additional plaster samples (8 ceiling and 8 wall plaster samples) were all non-detect for asbestos.

Materials that contain trace amounts of asbestos are not subject to U.S. EPA or New York regulations for the handling and disposal of asbestos, OSHA still regulates any work which will disturb materials identified with trace amounts of asbestos (reference the November 24, 2003 OSHA Interpretation document - Compliance Requirements For Renovation Work Involving Materials Containing Less Than 1% Asbestos). Therefore, any Contractors disturbing these materials will need to comply with components of 29 CFR 1926.1101, as detailed in the 2003 OSHA Interpretation document.

ECS recommends where a material type has been identified as asbestos containing that other materials with similar color, texture, age and size throughout the building’s interior and exterior be assumed to contain asbestos. Please refer to Section 4.1 for a complete list of building materials that were reported positive for asbestos and to Section 4.2 for materials that were assumed to contain asbestos.

The tan surfacing material identified as an extra layer in a sample collected from from 414A during the previous survey, was identified as an ACM. However, that tan surfacing material was not observed at the time of our supplemental sampling. ECS collected another sample of the ceiling plaster in the same general location (sample 63) and only two layers (gray base coat and white skim coat) were identified (both non-detect). ECS believes that the tan plaster surfacing may have been contamination from the ceiling tile glue dots associated with the ceiling systems. ECS recommends that where the ceiling will be disturbed during renovations; the existing materials (glue dots and plaster) be abated by a licensed and qualified abatement contractor.

ECS recommends that a project specification be prepared to delineate and quantify known and suspect hazardous and regulated materials in the buildings and to outline proper procedures for the abatement. This will help protect the owner’s liability in better defining the scope of work and contractors’ roles and responsibilities in the abatement process and holding the contractor accountable for the performance of the project. The specification typically defines the Contractor’s scope of work and outline requirements and procedures that must be followed for the project. The intent of the specification is to give performance requirements for the Contractor so that the project can be completed safely and in compliance with applicable federal and state regulations. Typically, the specification document serves as part of the site owner’s contract with the contractor.

June 4, 2020

Prior to any future renovation or demolition that would affect the identified ACMs, proper abatement would be required. It should be noted that several building materials sampled in the building contained a positive and negative result for asbestos. If renovations involving these materials are proposed, additional delineation would be recommended. The asbestos abatement should be performed by a licensed abatement contractor in accordance with EPA, NY DOL Code 56, and Occupational Safety and Health Administration (OSHA) requirements. Sample location diagrams and asbestos (including trace materials) extent diagrams are attached to this report.

If ACMs are to be removed, New York State requires that a project monitor oversee the abatement.

This involves collecting air samples from within and outside abatement work areas to monitor the asbestos abatement contractor’s work practices over the course of the project. The industrial hygienist should evaluate if the asbestos abatement work is in accordance with project specifications, U.S. EPA regulation 40 CFR Part 61-National Emission Standards for Hazardous Air Pollutants Subpart M: National Emission Standard for Asbestos, and U.S. Occupational Safety and Health Administration (OSHA) regulation 29 CFR 1926.1101 – Asbestos in Construction. The industrial hygienist should assess each work area to monitor the removal of ACMs. Only after the industrial hygienist has determined the identified ACMs have been removed should final clearance air samples be collected.

Suspect ACMs not observed due to inaccessibility or not sampled due to the destructive means that sampling would require may also be encountered during construction activities. At the time of the survey, only limited destructive means were used to locate or sample suspect ACMs; therefore, additional suspect ACMs may remain within inaccessible areas that include, but are not limited to, sub-grade walls, structural members, topping slabs, exterior areas, sub-grade sealants, flooring located below underlayments, vapor barriers, pipe trenches and other subsurface utilities, etc. If additional suspect ACMs are uncovered which were not accessible during this survey, it is recommended that these materials either be assumed to contain asbestos or be sampled prior to disturbance upon discovery for asbestos content by an asbestos inspector in accordance with 29 CFR

1926.1101 and NY DOL Code Rule 56.

6.0 LIMITATIONS

The conclusions and recommendations presented within this report are based upon a reasonable level of assessment within normal bounds and standards of professional practice for a site in this particular geographic setting. ECS is not responsible or liable for the discovery and elimination of hazards that may potentially cause damage, accidents, or injuries.

The observations, conclusions, and recommendations pertaining to environmental conditions at the subject site are necessarily limited to conditions observed, and/or materials reviewed at the time this study was undertaken. No warranty, expressed or implied, is made with regard to the conclusions and recommendations presented within this report. This report is provided for the exclusive use of the client. This report is not intended to be used or relied upon in connection with other projects or by other unidentified third parties without the written consent of ECS and the client.

Our recommendations are in part based on federal, state, and local regulations and guidelines. ECS does not assume the responsibility of the person(s) in charge of the site, or otherwise undertake responsibility for reporting to any local, state, or federal public agencies, any conditions at the site that may present a potential danger to public health, safety, or the environment. Under this scope of

June 4, 2020 services, ECS assumes no responsibility regarding any response actions initiated as a result of these findings. General compliance with regulations and response actions are the sole responsibility of the Client and should be conducted in accordance with local, state, and/or federal requirements.

During this study, samples were submitted for analysis at an accredited laboratory via polarized light microscopy. As with any similar survey of this nature, actual conditions exist only at the precise locations from which samples were collected. Certain inferences are based on the results of this sampling and related testing to form a professional opinion of conditions in areas beyond those from which the samples were collected. No warranty, expressed or implied, is made.

June 4, 2020

Appendix I: Asbestos Sample Location Diagram

82 SF 96 SF

96 SF 24

S

F634 SF

403 SF

616 SF

247 SF

142 SF 121 SF

765 SF

344 SF

122 SF

1256 SF616 SF

103 SF

121 SF

110 SF

125 SF

105 SF

97 SF

88 SF

241 SF

112 SF

105 SF

348 SF46

4 S

F

178 SF

189 SF 109 SF

82 SF

35 SF

187 SF

245 SF

111 SF

589 SF

115 SF

238 SF

92 SF

98 SF

98 SF

0 S

F

226 SF

43 SF

201 SF

310A

DINING AREA

OCC. THERAPY

KITCHEN

WELLNESS

FOOD SERVICE

VACANT

311A

WASHING

DISH

309B

WELLNESS

9A

VENDING AREA

UP

EL

EV

. 1

ASST. CHIEF

O.T. ADL RM.

OFFICE

OT CLINIC

311B

HBDT

305 STAGE

CHAPEL

E.M.S.

318A

O.D. RM.

316A

TOILET

UNISEX

362 353

CONFERENCE RM

SSR DINING RM.

302A

DATA CLOSET

3H A1

-7

SWSW3-76

3H A2

-7

3H A3

-7

DN

3HA5-76

CPAC

ST

OR

AG

E

CO

NURSE MANGR

RELEASE OF INFO.

EQUIPMENT RM

350C

TOILET

SOCIAL

321D

ELEV. NO.3

ELEV. NO.2

MOD LOUNGE

319B

319A

320B

320A

OFFICE

DIRTY UTIL

307B

OFFICE/STORG.

STORT TERM REHAB

STR

FAMILY ROOM

616 SF

STORE AREA

143 SF

100 SF

62 SF

118 SF

97 SF

3HA4-76

215 SF

321D

WORKER

RESP. WRKST. WAITING ROOM EXAM ROOM

CONSULT RM.

ANDREWS

D&T

D&T

RELEASE OF INFO.

RELEASE OF INFO.

PRIVACY OFFICER

LONGWELL

D.O.

BARRON

D.O.

FILKINS

D.O.

D&T

SHOE

MVAC

SCHU

MVAC

CONRAD

SPD

VSC

OLIN/STRATTON

GEC

D&T

NFS

NFS

NFS

NFS

NFS ()

() DANGERFIELD

D.O.

SPD ()

SPD

HARIK

RESP. TH.

D&T

D&T

RESP. TH.

RESP. TH.

SPD

D&T

CRIST

D&T

MVAC

D.O.

GEC

GEC

STETTER

GEC

120 SF

114 SF

94 SF

123 SF

115 SF

95 SF

66 SF

84 SF

STAIR CORRIDOR

SPS

ELEV. 5

DN

SWAN3-76

TOILET

TOILET

357B

SPD WK. RM.

2,250 SF

DN

STAFF

CPAC COORD.

RATLIFF

GEC

SPS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h 6/

/2

:3

9:

P M

DESIGN DEVELOPMENT

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Watson Engineering 1112 State Route 434 Owego, NY 13827 (607)223-4334

Electrical Consultant C&S Companies 499 Col Eileen Collins Blvd Syracuse, NY 13212 (315)455-2000

DESIGN STEAM AND UPGRADE

VENTILATION, BUILDING 76

BATH VAMC, BATH, NY

528A6-19-614

BUILDING 76

Project Director

12/05/2019 JWE JAHRevisions: Date:

Asbestos Consultant ECS Mid-Atlantic, LLC 4507 Metropolitan Ct Frederick, MD 21704 (301)668-4303

Cost Estimating Trophy Point 4588 South Park Ave Buffalo, NY 14219 (716)823-0006

M-101

MECHANICAL PLAN -

THIRD FLOOR SOUTH

SEE M-104 FOR

CONTINUATION

SCALE: 1/8" = 1'-0"

MECHANICAL PLAN - THIRD FLOOR SOUTHE8

3, 4, 5, 6

AutoCAD SHX Text D.F.

AutoCAD SHX Text D.F.

AutoCAD SHX Text 6"

AutoCAD SHX Text 12x8

AutoCAD SHX Text 10"

AutoCAD SHX Text

MATCH

AutoCAD SHX Text

MATCH

AutoCAD SHX Text

BUILDING ELEVATIONS

AutoCAD SHX Text

FLOOR

AutoCAD SHX Text

ELEVATION

AutoCAD SHX Text

GROUND FLOOR

AutoCAD SHX Text 1124'

AutoCAD SHX Text

AutoCAD SHX Text 1134'

AutoCAD SHX Text

AutoCAD SHX Text 1146'

AutoCAD SHX Text

AutoCAD SHX Text 1158'

AutoCAD SHX Text

AutoCAD SHX Text 1170'

AutoCAD SHX Text

AutoCAD SHX Text 1182'

AutoCAD SHX Text

AutoCAD SHX Text 1194'

AutoCAD SHX Text

ATTIC

AutoCAD SHX Text 1206'

AutoCAD SHX Text

AutoCAD SHX Text

AREA FOR 4'X8' CHASE AND FLOOR PENETRATIONS

AutoCAD SHX Text

LEGEND

AutoCAD SHX Text NOTE: 1. APPROXIMATE THIRD FLOOR CONDITIONED AREA: 9350 SQ. FT.APPROXIMATE THIRD FLOOR CONDITIONED AREA: 9350 SQ. FT.

AutoCAD SHX Text

KEY NOTES:

AutoCAD SHX Text

AutoCAD SHX Text

LOCATION FOR NEW 4'X8' DUCT CHASE AND FLOOR PENETRATIONS.

AutoCAD SHX Text

DATA CLOSET

78 SF

TELEHEALTH

TOILET

ROOM

IRM TRAINING

STORAGE

VESTIBULE

414B

MENS TOILET

H.A.C.

431A

TOIL.

407A

EXAM RM

F.H.R

TOILET

405 404

TOILET

EL

EV

. 1

UP

CHIRO OFF.

432A

TOILET

MENS

STORAGE

SWSW4-76

427A

408A

CO

RR

ID

OR

4H

A1 -7

4HA3-76

4H A2

-7

STORAGE

414A

413A

TOILET

71 SF

242 SF 244 SF

105 SF

108 SF

111 SF

107 SF

115 SF

92 SF

116 SF

97 SF

132 SF

120 SF

732 SF

P.B.

TEMP.

34 SF

226 SF

100 SF

230 SF

75 SF

222 SF

PAIN MGMT.

109 SF

2 S

F

269 SF

53 SF

76 SF 253 SF 252 SF

138 SF

4 S

F

116 SF

45 SF

81 SF

38 SF

25 SF

109 SF

240 SF

886 SF

MVAC

417A 425A

115 SF 116 SF

109 SF

PAIN MGMT.

PAIN MANGMT

C&P

97 SF

238 SF

96 SF

STERILE SPLY.

SPECIALTY SUPPORT

173 SF

204 SF

178 SF

224 SF

434 SF

276 SF

38 SF

83 SF

351 SF

86 SF

49 SF

DIRTY

47 SF

199 SF

401A

EXAM ROOM

197 SF

217 SF

253 SF

433A

EMPLOYEETOILET

STORAGE

MED RM 434B

4HA5-76

434A

ELEV. NO.2

ELEV. NO.3

NURSING OFFICE

CHIRO EXAM

432B

F.H.R

WAITING

EQUIP. STRG.

EMP. HEALTH

()() EXAM ROOM

D&T

D&T()

IT

SCHMITT

MVAC

MVAC

WHITBEE/PACKER

MVAC

BOBBY

EXAM RM

D&T

EXAM RM

D&T

PROV. OFFICE

SMITH

MVAC

PROSTHETICS

MVAC

PROSTHETICS

WEBSTER

MVAC

TELEHEALTH WAITING

MVAC

TELEHEALTH

FITZENMAIER

MVAC

TELEHEALTH EXAM RM

BVAC

C&P

BVAC

C&P

BVAC

C&P

() BVAC

C&P

MVAC

TELEHEALTH

DICK

BVAC/MVAC

BREAK ROOM

QM

INFECT. CONTROL

FLEISCHMAN

BOBBY

MVAC

BOBBY

MVAC

CHIRO EXAM

D&T

CHIRO EXAM

D&T

PODIATRY EXAM

MVAC

BARBADO

D&T

OFFICE

VACANT ()

D&T

D&T

D&T

D&T D&T D&T

D&T D&T

EXAM ROOM

MVAC

TELEHEALTH EXAM RM

MVAC

TELEHEALTH GRP RM

MVAC

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h 6/

/2

:3

9:

P M

DESIGN DEVELOPMENT

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Watson Engineering 1112 State Route 434 Owego, NY 13827 (607)223-4334

Electrical Consultant C&S Companies 499 Col Eileen Collins Blvd Syracuse, NY 13212 (315)455-2000

DESIGN STEAM AND UPGRADE

VENTILATION, BUILDING 76

BATH VAMC, BATH, NY

528A6-19-614

BUILDING 76

Project Director

12/05/2019 JWE JAHRevisions: Date:

Asbestos Consultant ECS Mid-Atlantic, LLC 4507 Metropolitan Ct Frederick, MD 21704 (301)668-4303

Cost Estimating Trophy Point 4588 South Park Ave Buffalo, NY 14219 (716)823-0006

M-102

MECHANICAL PLAN -

FOURTH FLOOR SOUTH

SEE M-106 FOR

CONTINUATION

SCALE: 1/8" = 1'-0"

MECHANICAL PLAN - FOURTH FLOOR SOUTHE8

11 36 37

21 28

AutoCAD SHX Text

MATCH

AutoCAD SHX Text

MATCH

AutoCAD SHX Text

AutoCAD SHX Text

BUILDING ELEVATIONS

AutoCAD SHX Text

FLOOR

AutoCAD SHX Text

ELEVATION

AutoCAD SHX Text

GROUND FLOOR

AutoCAD SHX Text 1124'

AutoCAD SHX Text

AutoCAD SHX Text 1134'

AutoCAD SHX Text

AutoCAD SHX Text 1146'

AutoCAD SHX Text

AutoCAD SHX Text 1158'

AutoCAD SHX Text

AutoCAD SHX Text 1170'

AutoCAD SHX Text

AutoCAD SHX Text 1182'

AutoCAD SHX Text

AutoCAD SHX Text 1194'

AutoCAD SHX Text

ATTIC

AutoCAD SHX Text 1206'

AutoCAD SHX Text

AREA TO BE CONDITIONED

AutoCAD SHX Text

AREA FOR POTENTIAL 4'X8' CHASE

AutoCAD SHX Text

LEGEND

AutoCAD SHX Text NOTE: 1. APPROXIMATE FOURTH FLOOR CONDITIONED AREA: 23450 SQ. FT. APPROXIMATE FOURTH FLOOR CONDITIONED AREA: 23450 SQ. FT. 2. ALL EXISTING DUCT WORK ON FOURTH FLOOR SHALL BE DEMOLISHED.ALL EXISTING DUCT WORK ON FOURTH FLOOR SHALL BE DEMOLISHED.

AutoCAD SHX Text

KEY NOTES:

AutoCAD SHX Text

AutoCAD SHX Text

LOCATION FOR NEW 4'X8' DUCT CHASE AND FLOOR PENETRATIONS.

STORAGE

TOILET

439A

UP

460461

DATA CLOSET

PROG. ASST.

TOILET

440A

STORAGE

4H A7

-7

456A

TOILET

456B

EMS STOR

STORAGE457

NO.4

ELEV.

ECHO RM

D.F.

FHR

DN

SWNW4-76

TOILET

UNASSIGN 448

SW

EX

4-

DN

4HA6-76

HOPTEL/FAMTEL LOUNGE

CONFERENCE RM

EYE EXAM

FAMTEL BDRM

HOPTEL BDRM

439B

439C

123 SF

299 SF

112 SF

175 SF

248 SF

122 SF

35 SF

30 SF

H.A.C.

143 SF 74 SF 145 SF

442 SF

675 SF

107 SF 112 SF

WAITING RM

107 SF

92 SF

281 SF

44 SF

50 SF

653 SF

40 SF 65 SF

103 SF

113 SF

0 S

114 SF

112 SF

227 SF

216 SF

166 SF

463A

166 SF

PROG. ASST.

MED INSTR TECH

75 SF

191 SF

217 SF

87 SF

465B

CLEAN UTL.

87 SF

464A

MED. RM.

SPECIALTY SUPPORT

EYE EXAM

166 SF

173 SF

265 SF

156 SF

47 SF

EL. CLOS.CLOS.

9 SF 17 SF

374 SF

508 SF

276 SF

900 SF

NC

T

4HA4-76

4HA5-76

RETHERM. ROOM

464465

UP

465A

SWC4-76

LOW VISION CLINIC

WOMENS

EMS

D.O.

EMS

MVAC ()

D&T

MVAC

VSC

VSC

VSC

VSC

HOPTEL BDRM

VSC

FAMTEL BDRM

HOPTEL BDRM

MED INSTR TECH

MVAC()

IT

SYTRICK

D&T

EYE EXAM

HANRAHAN

D&T()

D&T

SUTRYK

D&T

D&T

STORAGE

D&T

STORAGE

D&T

EMS

LACTATION RM.

HERRICK

CARDIOLOGY

EXAM RM.

D&T

EXAM RM

D&T

D&T

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h 6/

/2

:3

9:

P M

DESIGN DEVELOPMENT

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Watson Engineering 1112 State Route 434 Owego, NY 13827 (607)223-4334

Electrical Consultant C&S Companies 499 Col Eileen Collins Blvd Syracuse, NY 13212 (315)455-2000

DESIGN STEAM AND UPGRADE

VENTILATION, BUILDING 76

BATH VAMC, BATH, NY

528A6-19-614

BUILDING 76

Project Director

12/05/2019 JWE JAHRevisions: Date:

Asbestos Consultant ECS Mid-Atlantic, LLC 4507 Metropolitan Ct Frederick, MD 21704 (301)668-4303

Cost Estimating Trophy Point 4588 South Park Ave Buffalo, NY 14219 (716)823-0006

M-103

MECHANICAL PLAN -

FOURTH FLOOR NORTH

SEE M-105 FOR

CONTINUATION

SCALE: 1/8" = 1'-0"

MECHANICAL PLAN - FOURTH FLOOR NORTHE8

12 38

15 33

22 30 40 41

23 31

24 32

AutoCAD SHX Text

MATCH

AutoCAD SHX Text

MATCH

AutoCAD SHX Text

AutoCAD SHX Text

BUILDING ELEVATIONS

AutoCAD SHX Text

FLOOR

AutoCAD SHX Text

ELEVATION

AutoCAD SHX Text

GROUND FLOOR

AutoCAD SHX Text 1124'

AutoCAD SHX Text

AutoCAD SHX Text 1134'

AutoCAD SHX Text

AutoCAD SHX Text 1146'

AutoCAD SHX Text

AutoCAD SHX Text 1158'

AutoCAD SHX Text

AutoCAD SHX Text 1170'

AutoCAD SHX Text

AutoCAD SHX Text 1182'

AutoCAD SHX Text

AutoCAD SHX Text 1194'

AutoCAD SHX Text

ATTIC

AutoCAD SHX Text 1206'

AutoCAD SHX Text

AREA TO BE CONDITIONED

AutoCAD SHX Text

LEGEND

NOTE: 1. APPROXIMATE FOURTH FLOOR CONDITIONED AREA: 23450 SQ. FT. APPROXIMATE FOURTH FLOOR CONDITIONED AREA: 23450 SQ. FT. 2. ALL EXISTING DUCT WORK ON FOURTH FLOOR SHALL BE DEMOLISHED.ALL EXISTING DUCT WORK ON FOURTH FLOOR SHALL BE DEMOLISHED.

PACT OFFICE

514A

STORAGE

512E

UP

512H

512C

STORAGE

513A

TOILET

510A

ELEV. 1

RN OFFICE

SW OFFICE

ROOM

508 507

HAC

EXAM RM4

WOMEN TOILET

527A

SHOWER

518F

ELEV. NO.3

EXAM RM7

503A

528A

EXAM RM

LOBBY

SWSW5-76

DATA

OFFICE

EXAM RM2

EXAM RM1

DN

5HA4-765HA3-76

5HA1-76

5HA2-76

EXAM RM

WAITING ROOM

SUPPLY RM. RECEPTION

518E

PSYC. OFFICE GRP RM

CASE MNGR. OFFICE

SW OFFICE

LOCUM/TENON

TELEMEDICINE CONF.

518G

518D

518B

518C

518A

518H

518I

518J

518K

GROUP RM

OFFICE

CLINICAL PSY. OFFICE

TESTING

PSYCH. OFFICE RN MNG OFFICE

TESTING

CLINIC MNGR. OFFICE

512I 512A

512B

512G

512F 512D

BH WAITING

CLINICAL PHARM.

514B

CONF. RM.

VEST.

EXAM RM5

505A

EXAM RM6

504A

STERILE STORAGE

528C

528E 528D

MED RM

UTILITY

SOILED

PATIENT ED.

500A

501A 501

EQUIP.

TOILET TOILET

39 S.F.

75 S.F.

154 SF

97 SF

240 SF

107 SF

133 SF

160 SF111 SF

114 SF 115 SF

119 SF117 SF

94 SF

98 SF

264 SF

45 SF

76 SF

110 SF

110 SF

76 SF

139 SF

85 SF

141 SF

76 SF

110 SF

110 SF

427 SF

114 SF

120 SF259 SF

42 SF

THERAPIST OFF.

TREATMENT RM

BREAK RM

PACT OFFICE

590 SF

38 SF48 SF

36 SF

40 SF

63 SF

104 SF

126 SF

109 SF

159 SF

168 SF

80 SF

113 SF

108 SF

131 SF

122 SF

134 SF

169 SF

114 SF119 SF113 SF

146 SF

25 SF

127 SF

79 SF167 SF

241 SF

600 SF

367 SF

92 SF

115 SF 40 SF

407 SF

NURSE WORK RM.

ELEVATOR528B

EXAM RM11

ELEV. NO.2

NURSE

500B

EXAM

MENS WOMENS

96 SF

50 SF

136 SF

OFFICE OFFICE

BVAC

BVAC

BVAC

CHIEF

TYMESON

BVAC

PSYC. OFFICE

BVAC

SW OFFICE

BVAC

SW OFFICE

BVAC

BVAC

BVAC

BVAC

BVAC

LAYOLA

BVAC

BVAC

BVAC

BVAC

DR. E

BVAC

BORMAN

BVAC

BVAC

BVAC

BVAC

BVAC

BVAC

BVAC

BVAC

BVAC

BVAC

BVAC

EMS

BVAC

BVAC

BVAC

MVAC

MVAC

IT

MVAC

MVAC

MVAC []

MVAC

MVAC

PFITZENMAIER/

MVAC

MVAC

MVAC

MVAC

MVAC

EXAM RM

SPS

MVAC

MVAC []

MVAC

MVAC

MVAC []

MVAC

COTTONE

DR. AUNG

M.DICK

UPDIKE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h 6/

/2

:3

9:

P M

DESIGN DEVELOPMENT

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Watson Engineering 1112 State Route 434 Owego, NY 13827 (607)223-4334

Electrical Consultant C&S Companies 499 Col Eileen Collins Blvd Syracuse, NY 13212 (315)455-2000

DESIGN STEAM AND UPGRADE

VENTILATION, BUILDING 76

BATH VAMC, BATH, NY

528A6-19-614

BUILDING 76

Project Director

12/05/2019 JWE JAHRevisions: Date:

Asbestos Consultant ECS Mid-Atlantic, LLC 4507 Metropolitan Ct Frederick, MD 21704 (301)668-4303

Cost Estimating Trophy Point 4588 South Park Ave Buffalo, NY 14219 (716)823-0006

M-104

MECHANICAL PLAN -

FIFTH FLOOR SOUTH

SEE M-108 FOR

CONTINUATION

SCALE: 1/8" = 1'-0"

MECHANICAL PLAN - FIFTH FLOOR SOUTHE8

AutoCAD SHX Text

MATCH

AutoCAD SHX Text

MATCH

AutoCAD SHX Text D.F.

AutoCAD SHX Text

AutoCAD SHX Text

BUILDING ELEVATIONS

AutoCAD SHX Text

FLOOR

AutoCAD SHX Text

ELEVATION

AutoCAD SHX Text

GROUND FLOOR

AutoCAD SHX Text 1124'

AutoCAD SHX Text

AutoCAD SHX Text 1134'

AutoCAD SHX Text

AutoCAD SHX Text 1146'

AutoCAD SHX Text

AutoCAD SHX Text 1158'

AutoCAD SHX Text

AutoCAD SHX Text 1170'

AutoCAD SHX Text

AutoCAD SHX Text 1182'

AutoCAD SHX Text

AutoCAD SHX Text 1194'

AutoCAD SHX Text

ATTIC

AutoCAD SHX Text 1206'

AutoCAD SHX Text

AREA FOR 4'X8' CHASE

AutoCAD SHX Text

LEGEND

AutoCAD SHX Text NOTE: 1. APPROXIMATE FIFTH FLOOR CONDITIONED AREA: 3500 SQ. FT.APPROXIMATE FIFTH FLOOR CONDITIONED AREA: 3500 SQ. FT.

AutoCAD SHX Text

KEY NOTES:

AutoCAD SHX Text

AutoCAD SHX Text

LOCATION FOR NEW 4'X8' DUCT CHASE AND FLOOR PENETRATIONS.

532532A

DIETICIAN 533A

558A

MENS TOILET

VACANT

534A

535A

UP

KITCHEN

STORE RM

PACT OFFICE

P.T. STOR.

555B

PHARM.

PACT TEAM 4

DATA CLOSET

TOILET

HAC

CORRIDOR

536A

5HA6-76

NO.4

FHR

ELEV.

DN

540A

CORRECTIVE THERAPY

MEETING RM

CHIEF, PM&R

PHYSICAL THERAPY

5HA7-76

SWC5-76

SW

EX

5-

SWNW5-76TOILETTOILET

DN

5H A7

-7

5HA4-76

561A

TOILET

559A

PSA OFFICE

WOUND CLINIC

CLINICAL PHARM.

NURSE STATION

TOILET

EXAM RM15

EXAM 17

534B

STORAGE

92 SF 209 SF

52 SF

117 SF

SW OFFICE

144 SF 34 SF

116 SF 123 SF

106 SF

117 SF

813 SF

283 SF

472 SF

211 SF

245 SF

143 SF

51 SF

190 SF

121 SF

140 SF

130 SF85 SF109 SF

123 SF

213 SF

218 SF

117 SF

58 SF80 SF

115 SF 69 SF

112 SF

217 SF

338 SF

0 S

F

590 SF

38 SF

8 SF

140 SF

128 SF

WOMENS

EXAM RM2

MVAC

MVAC

MVAC

PSA OFFICE

MVAC

PSA OFFICE

PACT OFFICE

MVAC

MVAC

MVAC

MVAC

MVAC

VACANT

MUNAY

MVAC

WAITING RM

MVAC []

D&T

BILLIE JO

MVAC

MVAC

WOMEN HLTH

EXAM RM1

WOMEN HLTH

MVAC

D&T

MVAC

D&T WOOD

PHARMACY

MELISSA

DR. HUA

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h 6/

/2

:3

9:

P M

DESIGN DEVELOPMENT

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Watson Engineering 1112 State Route 434 Owego, NY 13827 (607)223-4334

Electrical Consultant C&S Companies 499 Col Eileen Collins Blvd Syracuse, NY 13212 (315)455-2000

DESIGN STEAM AND UPGRADE

VENTILATION, BUILDING 76

BATH VAMC, BATH, NY

528A6-19-614

BUILDING 76

Project Director

12/05/2019 JWE JAHRevisions: Date:

Asbestos Consultant ECS Mid-Atlantic, LLC 4507 Metropolitan Ct Frederick, MD 21704 (301)668-4303

Cost Estimating Trophy Point 4588 South Park Ave Buffalo, NY 14219 (716)823-0006

M-105

MECHANICAL PLAN -

FIFTH FLOOR NORTH

SEE M-107 FOR

CONTINUATION

SCALE: 1/8" = 1'-0"

MECHANICAL PLAN - FIFTH FLOOR NORTHE8

43 44 45

46 50

51 56

52 57

53 58

AutoCAD SHX Text

MATCH

AutoCAD SHX Text

MATCH

AutoCAD SHX Text D.F.

AutoCAD SHX Text

AutoCAD SHX Text

BUILDING ELEVATIONS

AutoCAD SHX Text

FLOOR

AutoCAD SHX Text

ELEVATION

AutoCAD SHX Text

GROUND FLOOR

AutoCAD SHX Text 1124'

AutoCAD SHX Text

AutoCAD SHX Text 1134'

AutoCAD SHX Text

AutoCAD SHX Text 1146'

AutoCAD SHX Text

AutoCAD SHX Text 1158'

AutoCAD SHX Text

AutoCAD SHX Text 1170'

AutoCAD SHX Text

AutoCAD SHX Text 1182'

AutoCAD SHX Text

AutoCAD SHX Text 1194'

AutoCAD SHX Text

ATTIC

AutoCAD SHX Text 1206'

AutoCAD SHX Text

AREA TO BE CONDITIONED

AutoCAD SHX Text

AREA FOR POTENTIAL 4'X8' CHASE

AutoCAD SHX Text

LEGEND

AutoCAD SHX Text

KEY NOTES:

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING CHASE TO BE EXPANDED. ALL DUCTWORK WITHIN TO BE DEMOLISHED

AutoCAD SHX Text

NOTE: 1. APPROXIMATE FIFTH FLOOR CONDITIONED AREA: 3500 SQ. FT.APPROXIMATE FIFTH FLOOR CONDITIONED AREA: 3500 SQ. FT.

SW-6/76

PENTHOUSE

ELEVATOR

NO.1 6ATS1-76

6HA5-76

6ATS1-76

6ATS2-76

6ATS3-76

6HA1-76

DATA CLOSET

6HA4-76

ELEV. NO.3

611A

ELEV. NO.2DIRTY UTL.

605 605A 604 606 603

607A

HAC

RESTROOM

179 SF 180 SF

186 SF

183 SF

195 SF

85 SF

252 SF 185 SF 184 SF 177 SF 189 SF

170 SF

147 SF

CORRIDOR

6HA3-76

125 SF

409 SF

498 SF

302 SF

115 SF

GROUP ROOM

SPACE

PROVIDER OFF.

OFFICE MNGR.

MED RM

21 SF

OFFICE

MED. RM.

OFFICE BREAKRM.

STORAGE

LAUNDRY CHUTE

LAYOLA

OFFICE

PATIENT RM.

MVAC

PATIENT RM.

PATIENT RM.

IT

PHARMACY

MVAC MVAC MVAC MVAC

MVAC

MVAC

MVAC

MVAC

MVAC

MVAC

MVAC

MVAC

AHU-S-1

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h 6/

/2

:3

9:

P M

DESIGN DEVELOPMENT

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Watson Engineering 1112 State Route 434 Owego, NY 13827 (607)223-4334

Electrical Consultant C&S Companies 499 Col Eileen Collins Blvd Syracuse, NY 13212 (315)455-2000

DESIGN STEAM AND UPGRADE

VENTILATION, BUILDING 76

BATH VAMC, BATH, NY

528A6-19-614

BUILDING 76

Project Director

12/05/2019 JWE JAHRevisions: Date:

Asbestos Consultant ECS Mid-Atlantic, LLC 4507 Metropolitan Ct Frederick, MD 21704 (301)668-4303

Cost Estimating Trophy Point 4588 South Park Ave Buffalo, NY 14219 (716)823-0006

M-106

MECHANICAL PLAN -

SIXTH FLOOR SOUTH

SEE M-110 FOR

CONTINUATION

SCALE: 1/8" = 1'-0"

MECHANICAL PLAN - SIXTH FLOOR SOUTHE8

AutoCAD SHX Text

MATCH

AutoCAD SHX Text

MATCH

AutoCAD SHX Text

CHP-3-2

AutoCAD SHX Text

HWP-4

AutoCAD SHX Text

HX-4

AutoCAD SHX Text

AutoCAD SHX Text

BUILDING ELEVATIONS

AutoCAD SHX Text

FLOOR

AutoCAD SHX Text

ELEVATION

AutoCAD SHX Text

GROUND FLOOR

AutoCAD SHX Text 1124'

AutoCAD SHX Text

AutoCAD SHX Text 1134'

AutoCAD SHX Text

AutoCAD SHX Text 1146'

AutoCAD SHX Text

AutoCAD SHX Text 1158'

AutoCAD SHX Text

AutoCAD SHX Text 1170'

AutoCAD SHX Text

AutoCAD SHX Text 1182'

AutoCAD SHX Text

AutoCAD SHX Text 1194'

AutoCAD SHX Text

ATTIC

AutoCAD SHX Text 1206'

AutoCAD SHX Text

KEY NOTES:

AutoCAD SHX Text

AutoCAD SHX Text

LOCATION OF FUTURE AHU-S-1

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

FUTURE HX-4 CONNECTION TO EXISTING BUILDING STEAM AND CONDENSATE LINES

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

FUTURE SUPPLY AND RETURN DUCTWORK

AutoCAD SHX Text

AutoCAD SHX Text NOTE: 1. WORK ON THIS PAGE IS SHOWN FOR FUTURE COORDINATION. NO WORK ON THIS PAGE IS SHOWN FOR FUTURE COORDINATION. NO MECHANICAL WORK SHOWN SHALL BE DONE UNDER THIS CONTRACT.

AutoCAD SHX Text

LEGEND:

FUTURE WORK (PERFORMED UNDER SEPERATE CONTRACT)

SW

EX

6-

UP

ACCESS

PANELS

PANELS

ACCESS

6ATN1-76

PENTHOUSE

NO.4

ELEVATOR

6ATN3-76

6HA6-76 6ATN5-76

6H A7

-7

6ATN4-76

6HA2-76 446 SF

7 S

F

615R 615A

UTIL.FH

TELE. CLOS. CLOS.

UP

CS-6/76

626 624

623A 624A

622 621 620

LINEN

HAC

617A617 616A

CLEAN

RESTROOM

CORRIDOR

6HA3-76

125 SF

TOILET

66 SF

250 SF

109 SF

37 SF

23 SF

362 SF

336 SF

224 SF 219 SF

272 SF 80 SF

186 SF

22 SF

229 SF366 SF

302 SF

665 SF

PROVIDER OFF.

OFFICE

STORAGE

MED RM

NURSES STATION

227 SF

13 SF 19 SF

PATIENT RM.

ELECTRICAL CLOSET

PATIENT RM.

PATIENT RM.

PATIENT RM.

[] PATIENT RM.

[] PATIENT RM.

MVAC

MVAC

MVAC MVAC

MVAC

EMS

MVAC

MVAC MVAC MVAC

AH

U-

5- N

OA

EA

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h 6/

/2

:3

9:

P M

DESIGN DEVELOPMENT

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Watson Engineering 1112 State Route 434 Owego, NY 13827 (607)223-4334

Electrical Consultant C&S Companies 499 Col Eileen Collins Blvd Syracuse, NY 13212 (315)455-2000

DESIGN STEAM AND UPGRADE

VENTILATION, BUILDING 76

BATH VAMC, BATH, NY

528A6-19-614

BUILDING 76

Project Director

12/05/2019 JWE JAHRevisions: Date:

Asbestos Consultant ECS Mid-Atlantic, LLC 4507 Metropolitan Ct Frederick, MD 21704 (301)668-4303

Cost Estimating Trophy Point 4588 South Park Ave Buffalo, NY 14219 (716)823-0006

M-107

MECHANICAL PLAN -

SIXTH FLOOR NORTH

SEE M-109 FOR

CONTINUATION

SCALE: 1/8" = 1'-0"

MECHANICAL PLAN - SIXTH FLOOR NORTHE8

CHWS

CHWR

CHWS

CHWR

CH

W

S

CH

W

R

CH

W

S

CH

W

R

64 65

LABELED ACM

MAG INSULATION ON HANGARS

AutoCAD SHX Text

6ATN2-76

AutoCAD SHX Text D.F.

AutoCAD SHX Text

HAZARDOUS AREA

AutoCAD SHX Text

MATCH

AutoCAD SHX Text

MATCH

AutoCAD SHX Text

CHP-5-N

AutoCAD SHX Text

HWP-4

AutoCAD SHX Text

HX-4

AutoCAD SHX Text

AutoCAD SHX Text

BUILDING ELEVATIONS

AutoCAD SHX Text

FLOOR

AutoCAD SHX Text

ELEVATION

AutoCAD SHX Text

GROUND FLOOR

AutoCAD SHX Text 1124'

AutoCAD SHX Text

AutoCAD SHX Text 1134'

AutoCAD SHX Text

AutoCAD SHX Text 1146'

AutoCAD SHX Text

AutoCAD SHX Text 1158'

AutoCAD SHX Text

AutoCAD SHX Text 1170'

AutoCAD SHX Text

AutoCAD SHX Text 1182'

AutoCAD SHX Text

AutoCAD SHX Text 1194'

AutoCAD SHX Text

ATTIC

AutoCAD SHX Text 1206'

AutoCAD SHX Text

AREA FOR POTENTIAL 4'X8' CHASE

AutoCAD SHX Text

LEGEND

AutoCAD SHX Text

KEY NOTES:

AutoCAD SHX Text

AutoCAD SHX Text

PROPOSED LOCATION OF AHU-5-N. ROUTE DUCTWORK THORUGH FLOOR TO SPACE BELOW.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING CHASE TO BE EXPANDED TO 4'X8' AND UTILIZED FOR FOURTH FLOOR DUCTWORK

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

24"X16" SUPPLY AND RETURN DUCTWORK DOWN TO FLOOR BELOW

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

3" CHILLED WATER SUPPLY AND RETURN FROM BELOW

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

1" CHILLED WATER SUPPLY AND RETURN TO ATTIC ABOVE

AutoCAD SHX Text

AutoCAD SHX Text 3"

AutoCAD SHX Text 3"

AutoCAD SHX Text 2"

AutoCAD SHX Text 2"

AutoCAD SHX Text 2"

AutoCAD SHX Text

AutoCAD SHX Text

CHILLED WATER SUPPLY AND RETURN TO FUTURE AHU-3-2

AutoCAD SHX Text

AutoCAD SHX Text 2"

AutoCAD SHX Text

AutoCAD SHX Text

CONNECT TO EXISTING BUILDING STEAM AND CONDENSATE RETURN LINES

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

LOUVERS TO BE INSTALLED IN ROOF

AutoCAD SHX Text

7ATC1-76

7ATC2-76

EA

OA

24" X 48"

24" X 48"

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h 6/

/2

:3

9:

P M

DESIGN DEVELOPMENT

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Watson Engineering 1112 State Route 434 Owego, NY 13827 (607)223-4334

Electrical Consultant C&S Companies 499 Col Eileen Collins Blvd Syracuse, NY 13212 (315)455-2000

DESIGN STEAM AND UPGRADE

VENTILATION, BUILDING 76

BATH VAMC, BATH, NY

528A6-19-614

BUILDING 76

Project Director

12/05/2019 JWE JAHRevisions: Date:

Asbestos Consultant ECS Mid-Atlantic, LLC 4507 Metropolitan Ct Frederick, MD 21704 (301)668-4303

Cost Estimating Trophy Point 4588 South Park Ave Buffalo, NY 14219 (716)823-0006

M-108

MECHANICAL PLAN - ATTIC

SCALE: 1/8" = 1'-0"

MECHANICAL PLAN - ATTICD6

CHW

S

CHW

R

79 80

84 85

AutoCAD SHX Text

CHP-4

AutoCAD SHX Text

HWP-4

AutoCAD SHX Text

HX-4

AutoCAD SHX Text

AutoCAD SHX Text

BUILDING ELEVATIONS

AutoCAD SHX Text

FLOOR

AutoCAD SHX Text

ELEVATION

AutoCAD SHX Text

GROUND FLOOR

AutoCAD SHX Text 1124'

AutoCAD SHX Text

AutoCAD SHX Text 1134'

AutoCAD SHX Text

AutoCAD SHX Text 1146'

AutoCAD SHX Text

AutoCAD SHX Text 1158'

AutoCAD SHX Text

AutoCAD SHX Text 1170'

AutoCAD SHX Text

AutoCAD SHX Text 1182'

AutoCAD SHX Text

AutoCAD SHX Text 1194'

AutoCAD SHX Text

ATTIC

AutoCAD SHX Text 1206'

AutoCAD SHX Text

KEY NOTES:

AutoCAD SHX Text

AutoCAD SHX Text

PROPOSED LOCATION OF AHU-4.

AutoCAD SHX Text

AutoCAD SHX Text EXISTING CHASE TO BE EXPANDED TO 4'X8' AND UTILIZED FOR NEW FOURTH FLOOR 2'X4' SUPPLY AND RETURN DUCTWORK.

AutoCAD SHX Text

AHU-4

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

2" CHILLED WATER SUPPLY AND RETURN FROM BELOW

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

CONNECT TO EXISTING STEAM AND CONDENSATE RETURN LINES

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

LOUVERS TO BE INSTALLED IN ROOF

AutoCAD SHX Text

Appendix II: Asbestos Extent Drawings

82 SF 96 SF

96 SF 24

S

F634 SF

403 SF

616 SF

247 SF

142 SF 121 SF

765 SF

344 SF

122 SF

1256 SF616 SF

103 SF

121 SF

110 SF

125 SF

105 SF

97 SF

88 SF

241 SF

112 SF

105 SF

348 SF46

4 S

F

178 SF

189 SF 109 SF

82 SF

35 SF

187 SF

245 SF

111 SF

589 SF

115 SF

238 SF

92 SF

98 SF

98 SF

0 S

F

226 SF

43 SF

201 SF

310A

DINING AREA

OCC. THERAPY

KITCHEN

WELLNESS

FOOD SERVICE

VACANT

311A

WASHING

DISH

309B

WELLNESS

9A

VENDING AREA

UP

EL

EV

. 1

ASST. CHIEF

O.T. ADL RM.

OFFICE

OT CLINIC

311B

HBDT

305 STAGE

CHAPEL

E.M.S.

318A

O.D. RM.

316A

TOILET

UNISEX

362 353

CONFERENCE RM

SSR DINING RM.

302A

DATA CLOSET

3H A1

-7

SWSW3-76

3H A2

-7

3H A3

-7

DN

3HA5-76

CPAC

ST

OR

AG

E

CO

NURSE MANGR

RELEASE OF INFO.

EQUIPMENT RM

350C

TOILET

SOCIAL

321D

ELEV. NO.3

ELEV. NO.2

MOD LOUNGE

319B

319A

320B

320A

OFFICE

DIRTY UTIL

307B

OFFICE/STORG.

STORT TERM REHAB

STR

FAMILY ROOM

616 SF

STORE AREA

143 SF

100 SF

62 SF

118 SF

97 SF

3HA4-76

215 SF

321D

WORKER

RESP. WRKST. WAITING ROOM EXAM ROOM

CONSULT RM.

ANDREWS

D&T

D&T

RELEASE OF INFO.

RELEASE OF INFO.

PRIVACY OFFICER

LONGWELL

D.O.

BARRON

D.O.

FILKINS

D.O.

D&T

SHOE

MVAC

SCHU

MVAC

CONRAD

SPD

VSC

OLIN/STRATTON

GEC

D&T

NFS

NFS

NFS

NFS

NFS ()

() DANGERFIELD

D.O.

SPD ()

SPD

HARIK

RESP. TH.

D&T

D&T

RESP. TH.

RESP. TH.

SPD

D&T

CRIST

D&T

MVAC

D.O.

GEC

GEC

STETTER

GEC

120 SF

114 SF

94 SF

123 SF

115 SF

95 SF

66 SF

84 SF

STAIR CORRIDOR

SPS

ELEV. 5

DN

SWAN3-76

TOILET

TOILET

357B

SPD WK. RM.

2,250 SF

DN

STAFF

CPAC COORD.

RATLIFF

GEC

SPS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h 6/

/2

:3

9:

P M

DESIGN DEVELOPMENT

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Watson Engineering 1112 State Route 434 Owego, NY 13827 (607)223-4334

Electrical Consultant C&S Companies 499 Col Eileen Collins Blvd Syracuse, NY 13212 (315)455-2000

DESIGN STEAM AND UPGRADE

VENTILATION, BUILDING 76

BATH VAMC, BATH, NY

528A6-19-614

BUILDING 76

Project Director

12/05/2019 JWE JAHRevisions: Date:

Asbestos Consultant ECS…