About this file

This document provides details for a forthcoming solicitation to replace the roof on Building 1 at the VA Medical Center in Brooklyn, New York. The solicitation will be for a liquid applied roofing system along with related work such as installing roof drain strainers, copper flashing, and walking pads. Asbestos containing materials on the existing roof must also be abated. The estimated construction cost range is $1,000,000 to $2,000,000. Offerors must be SDVOSB roofing contractors approved under NAICS Code 238160 with a size standard of $16.5 million. The solicitation is anticipated to be issued on or around March 2, 2020, and will be set aside 100% for SDVOSB. Further details and any amendments will be posted to SAM.gov and FBO.gov using solicitation number 36C24220B0024.

36C24220B0024 AE-103A Demolition-New Plan Notes- Bld 1 Roof.pdf

View the file

Other files

File Type Posted
36C24220B0024-0003000.docx DOCX document
36C24220B0024-0002000.docx DOCX document
36C24220B0024-0002002.pdf PDF
36C24220B0024-0002001.pdf PDF
36C24220B0024-0001000.docx DOCX document
36C24220B0024-012.pdf PDF
36C24220B0024-003.pdf PDF
36C24220B0024-009.pdf PDF
36C24220B0024-004.pdf PDF
36C24220B0024-007.pdf PDF
36C24220B0024-013.pdf PDF
36C24220B0024-011.pdf PDF
36C24220B0024-006.pdf PDF
36C24220B0024-005.pdf PDF
36C24220B0024-008.pdf PDF
36C24220B0024-002.docx DOCX document
Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AREA OF WORK

BUILDING 1 ROOF

AutoCAD SHX Text Date

AutoCAD SHX Text Drawing No.

AutoCAD SHX Text Project No.

AutoCAD SHX Text of

AutoCAD SHX Text Dwg.

AutoCAD SHX Text Department of

AutoCAD SHX Text Veterans Affairs

AutoCAD SHX Text Revisions

AutoCAD SHX Text Date

AutoCAD SHX Text Approved: Division Chief

AutoCAD SHX Text Approved: Service Director

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text

BROOKLYN, NEW YORK

AutoCAD SHX Text Checked

AutoCAD SHX Text Location

AutoCAD SHX Text Drawn

AutoCAD SHX Text Project Title

AutoCAD SHX Text Building Number

AutoCAD SHX Text

NEW PLAN NOTES

AutoCAD SHX Text Replace Roof Building 1

AutoCAD SHX Text P.C.

AutoCAD SHX Text S.F.

AutoCAD SHX Text K.V.

AutoCAD SHX Text P.C.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 630A4-17-406

AutoCAD SHX Text 5-15-18

AutoCAD SHX Text

AE-103A

AutoCAD SHX Text

PLANNING & DESIGN

AutoCAD SHX Text

ENGINEERING

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text

%%UGENERAL CONTRACTOR RESPONSIBILITIES WITH REGARDS TO EXISTING CONDITIONS:

AutoCAD SHX Text 1- INFORMATION CONTAINED ON THESE DRAWINGS WITH REGARD TO EXISTING CONDITIONS OF CONSTRUCTION

AutoCAD SHX Text IS PROVIDED FOR THE CONVENIENCE OF THE GENERAL CONTRACTOR IN EXECUTING THE NEW WORK. EVERY

AutoCAD SHX Text

%%UGENERAL LIFE SAFETY NOTES:

AutoCAD SHX Text 1- EXISTING EXITS TO BE MAINTAINED DURING CONSTRUCTION. PROVIDE TEMPORARY PROTECTION AS REQUIRED TO MAINTAIN EGRESS AND

AutoCAD SHX Text

SAFE PASSAGE FROM THE BUILDING.

AutoCAD SHX Text 2- PROVIDE TEMPORARY PROTECTION WHILE WORKING IN THE SPACES BELOW OR ABOVE THE AREA OF CONSTRUCTION.

AutoCAD SHX Text

AND FOR INFECTION CONTROL.

AutoCAD SHX Text 3- PROVIDE SCAFFOLDS TEMPORARY PARTITION TO PROTECT OCCUPANTS FROM PHYSICAL HAZARD AND NOISE OF ALL DEMOLITION WORK, AutoCAD SHX Text ATTEMPT HAS BEEN MADE TO PROVIDE COMPLETE AND ACCURATE REPRESENTATION OF SUCH EXISTING

AutoCAD SHX Text CONDITIONS. THIS INTERPRETATION HAS BEEN TAKEN FROM AS-BUILT DRAWINGS SUPPLIED AND HAS BEEN

AutoCAD SHX Text FURTHER SUPPLEMENTED WITH FIELD MEASUREMENTS AND OBSERVATIONS. IT IS THE RESPONSIBILITY OF THE

AutoCAD SHX Text GENERAL CONTRACTOR TO FIELD VERIFY AND DOCUMENT ALL EXISTING DIMENSIONS, ELEVATIONS AND BENCHMARKS, AutoCAD SHX Text MATERIALS AND METHODS OF CONSTRUCTION THAT MAY AFFECT OR BE AFFECTED BY NEW WORK, AND TO

AutoCAD SHX Text COORDINATE SUCH FIELD VERIFICATION WITH THE CONTRACT DOCUMENTS AND THE EXECUTION OF THE WORK. NOTE

AutoCAD SHX Text ANY DISCREPANCIES AND/OR CONFLICTS INVOLVING EXISTING CONDITIONS SHALL BE BROUGHT TO THE COR'S

AutoCAD SHX Text

ATTENTION IMMEDIATELY.

AutoCAD SHX Text 2- FIELD VERIFICATION OF EXISTING CONDITIONS RELATED TO SPECIFIC PORTIONS OF THE WORK SHALL BE UNDERTAKEN

AutoCAD SHX Text IN ADVANCE TO ALLOW FOR THE TIMELY IDENTIFICATION OF EXISTING CONDITIONS THAT MAY AFFECT THE SCHEDULED

AutoCAD SHX Text INSTALLATION OF NEW WORK AS DESIGNATED AND DETAILED, AND TO AVOID UNDUE AND UNREASONABLE DELAYS TO

AutoCAD SHX Text THE PROJECT SHOULD SUCH CONDITIONS BE DISCOVERED. TIMELY IDENTIFICATION OF SUCH CONDITIONS SHALL PROVIDE

AutoCAD SHX Text FOR A MINIMUM PERIOD OF TEN (10) WORKING DAYS DURING WHICH TIME THE COR WILL EVALUATE THE CONDITIONS

AutoCAD SHX Text

AND MAKE RECOMMINDATIONS FOR ACCOMMODATING NEW WORK.

AutoCAD SHX Text 3- THE GENERAL CONTRACTOR OR CONSTRUCTION MANAGER AND AFFECTED SUBCONTRACTORS SHALL VISIT THE PROJECT SITE PRIOR

AutoCAD SHX Text TO SUBMITTING A PROPOSAL. THE CONTRACTOR SHALL BECOME GENERALLY FAMILIAR WITH THE PROJECT, AND WITH THE IMPACT

AutoCAD SHX Text OF THE NEW WORK ON THE EXISTING CONDITIONS. THE INFORMATION CONTAINED IN THESE DRAWINGS, WITH REGARD TO THE

AutoCAD SHX Text EXISTING CONDITIONS OF CONSTRUCTION IN NO WAY RELEASES THE GENERAL CONTRACTOR FROM THE RESPONSIBILITY FOR

AutoCAD SHX Text VERIFYING COMPLETELY ALL FIELD CONDITIONS RELATING TO AND AFFECTING THE EXECUTION OF THE WORK, AS DESCRIBED

AutoCAD SHX Text IN THESE CONTRACT DOCUMENTS. ANY AREAS OF CONCERN SHALL BE BROUGHT TO THE ATTENTION OF THE COR PRIOR

AutoCAD SHX Text TO SUBMITTING A PROPOSAL. NO ADDITIONAL CHARGE TO THE OWNER WILL BE APPROVED WHICH IS ATTRIBUTABLE TO THE

AutoCAD SHX Text

CONTRACTORS FAILURE TO DO THIS.

AutoCAD SHX Text 4- THE AREAS ADJACENT TO THE PROJECT ARE CURRENTLY OCCUPIED, AND MUST REMAIN COMPLETELY OPERATIONAL DURING THEIR

AutoCAD SHX Text NORMAL BUSINESS HOURS. COORDINATE WITH THE OWNER ANY CONSTRUCTION ACTIVITIES WHICH MAY IMPEDE THEIR NORMAL

AutoCAD SHX Text OPERATIONS, INCLUDING ANY ACTIVITY WHICH CREATES EXCESSIVE NOISE. NOTIFY ANY OCUPANTS OF THE BUILDING OF ANY CONSTRUCTION

AutoCAD SHX Text

ACTIVITIES WHICH MAY AFFECT THEIR ABILITY TO OPERATE NORMALLY.

AutoCAD SHX Text 5- IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO IDENTIFY POINTS OF ACCESS TO THE BUILDING AND TO VERIFY

AutoCAD SHX Text MINIMUM CLEARANCES AVAILABLE FOR USE IN TRANSPORTING NECESSARY CONSTRUCTION MACHINERY, EQUIPMENT, MATERIALS, AND

AutoCAD SHX Text COMPONENTS INTO THE BUILDING. USE OF SUCH POINTS OF ACCESS SHALL BE APPROVED BY THE OWNER.

AutoCAD SHX Text 6- IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR OR CONSTRUCTION MANAGER TO IDENTIFY EXISTING COMPONENTS AND

AutoCAD SHX Text ASSEMBLIES WITHIN THE BUILDING THAT ARE CONSTRUCTED AS FIRE RATED ASSEMBLIES. NOTE ANY DISCREPANCIES AND/OR

AutoCAD SHX Text CONFLICTS INVOLVING EXISTING CONDITIONS AND BRING THEM TO THE COR'S ATTENTION IMMEDIATELY.

AutoCAD SHX Text 7- CONTRACTOR TO MAINTAIN ALL MEANS OF EGRESS FOR DURATION OF CONSTRUCTION. WORK INCLUDES CONSTRUCTION OF FIRE RATED, AutoCAD SHX Text DUST PROOF TEMPORARY PARTITIONS, AND COVERED WALKS TO PUBLIC WAY AS REQUIRED BY REGULATIONS AND BUILDING CODES.

AutoCAD SHX Text 8- CONTRACTOR SHALL AT ALL TIMES MAINTAIN THE BUILDING IN A WEATHER TIGHT CONDITION.

AutoCAD SHX Text 9- CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PREVENT DAMAGE TO OWNER OCCUPIED AREAS ADJACENT TO NEW CONSTRUCTION

AutoCAD SHX Text OR OCCUPIED AREAS WHERE VARIOUS SYSTEM CONNECTIONS OR EXTENSIONS ARE REQUIRED AND IS RESPONSIBLE FOR DAMAGE CAUSED BY

AutoCAD SHX Text CONTRACTOR/SUB CONTRACTOR, OR ADVERSE WEATHER CONDITIONS, INCLUDING RAIN AND WIND.

AutoCAD SHX Text 10- THE CONTRACTOR SHALL EXERCISE CARE TO PREVENT ANY DAMAGE TO EXISTING CONDITIONS, UTILITIES, OR BUILDING ELEMENTS. DAMAGED

AutoCAD SHX Text ITEMS SHALL BE REPAIRED TO PREVIOUS CONDITION OR REMOVED AND PROMPTLY RETURNED TO SERVICE WITH NEW MATERIAL TO MATCH EXISTING.

AutoCAD SHX Text

%%UGENERAL ROOF REMOVAL NOTES:

AutoCAD SHX Text 1- DISCONNECT EXISTING ELECTRICAL, CONDUITS, AND ATTACHMENTS, ETC. AS REQUIRED WHEN INTERFERING WITH

AutoCAD SHX Text CONSTRUCTION WORK. RETURN DISTURBED ITEMS TO THEIR ORIGINAL FUNCTIONING CONDITIONS AFTER RELATED

AutoCAD SHX Text

CONSTRUCTION WORK IS COMPLETE.

AutoCAD SHX Text 2- PROVIDE STRUCTURAL STABILITY SUPPORT, SHORING/BRACING AS REQUIRED FOR REPAIRS/REPLACEMENT WORKS. SUBMIT

AutoCAD SHX Text STRUCTURAL STABILITY SHOP DRAWINGS FOR APPROVAL BEFORE THE START OF STRUCTURAL WORK.

AutoCAD SHX Text 3- PRIOR TO THE START OF DEMOLITION, THE CONTRACTOR SHALL CALL TO THE ATTENTION OF THE VA PROJECT ENGINEER (COR) ANY

AutoCAD SHX Text

DAMAGE, CRACKS, OR OTHER IMPERFECTIONS PERTAINING TO THE PROJECT.

AutoCAD SHX Text 4- BEFORE STARTING ANY DEMOLITION OPERATIONS, PROVIDE THE NECESSARY PROTECTIVE DEVICES WHERE REQUIRED, AND IN STRICT

AutoCAD SHX Text ACCORDANCE WITH OSHA RULES AND REGULATIONS, VA STANDARDS AND ALL APPLICABLE CODES.

AutoCAD SHX Text 5- DEMOLISHED MATERIALS, UNLESS NOTED OTHERWISE, SHALL BE DISPOSED OF OFF SITE ON A REGULAR BASIS AND IN A

AutoCAD SHX Text LEGAL MANNER. ALL DISPOSAL AND RUBBISH CARTING IS THE DEMOLITION CONTRACTORS RESPONSIBILITY.

AutoCAD SHX Text 6- REPAIR AND/OR REPLACE EXISTING ITEMS WHICH HAVE BECOME DAMAGED DURING THE PROGRESS OF THE WORK AND MAKE

AutoCAD SHX Text ANY AND ALL SUCH REPAIRS, REPLACEMENTS, AND MODIFICATIONS TO RESTORE THE DAMAGED ITEMS TO THEIR ORIGINAL CONDITION

AutoCAD SHX Text

AT THE TIME OF DAMAGE AT NO ADDITIONAL COST TO THE OWNER.

AutoCAD SHX Text 7- PATCH, FILL, AND REPAIR ALL SURFACES DISTURBED, CUT, DAMAGED, IN NEED OF REPAIR, OR MADE IMPERFECT BY ALTERATIONS OR

AutoCAD SHX Text REMOVAL WORK, AND AS REQUIRED TO PREPARE SURFACES FOR NEW MATERIALS AND ARRANGEMENTS.

AutoCAD SHX Text 8- EXISTING FINISHED AREAS DISTURBED BY DEMOLITION AND/OR RENOVATION SHALL BE PATCHED TO MATCH EXISTING.

AutoCAD SHX Text 9- CONTRACTOR SHALL SURVEY ALL EXISTING ROOF CONDITIONS PRIOR TO DEMOLITON, NOTING ALL ROOF HEIGHTS, PITCHES, ELEVATIONS, AutoCAD SHX Text AND DIMENSIONS. THESE SHALL BE MAINTAINED FOR THE NEW ROOF UNLESS NOTED OTHERWISE.

AutoCAD SHX Text 10- ALL STRUCTURAL INTERFERENCE OR STRUCTURAL WALLS, BEAMS, JOIST, COLUMNS, ETC. SHALL BE BROUGHT TO THE ATTENTION OF

AutoCAD SHX Text ARCHITECT FOR DECISION. NO FLOOR OR STRUCTURAL MEMBERS SHALL BE CUT WITHOUT PERMISSION OF A PE STRUCTURAL ENGINEER.

AutoCAD SHX Text

ALL PROPOSED SLEEVE/CORING SHALL BE REVIEWED BY COR.

AutoCAD SHX Text 11- REMOVE ALL ITEMS MARKED UP BY THE OWNER AS OWNER'S SALVAGE. TRANSPORT ITEMS TO OWNERS DESIGNATED STORAGE AREA(S).

AutoCAD SHX Text

CONTRACTORS FAILURE TO DO THIS, WILL RESULT IN CREDIT TO THE OWNER.

AutoCAD SHX Text

%%UGENERAL DEMOLITION NOTES:

AutoCAD SHX Text 1- CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, VERIFY ALL DIMENSIONS AND BE RESPONSIBLE ACCORDINGLY. ALL

AutoCAD SHX Text

CONDITIONS MUST BE VERIFIED- DO NOT SCALE FROM DRAWING.

AutoCAD SHX Text 2- BEFORE STARTING ANY DEMOLITION, CONTRACTOR MUST PROVIDE THE NECESSARY PROTECTIVE DEVICES WHERE REQUIRED AND IN

AutoCAD SHX Text STRICT ACCORDANCE WITH OSHA RULES AND REGULATIONS, VA STANDARDS AND ALL APPLICABLE CODES. PROVIDE FALL PROTECTION & SAFETY PLAN

AutoCAD SHX Text

FOR V.A. APPROVAL.

AutoCAD SHX Text 3- PRIOR TO DEMOLITION, THE CONTRACTOR SHALL CALL TO THE ATTENTION OF THE VA COR, ANY DAMAGE, CRACKS, AND/OR IMPERFECTIONS

AutoCAD SHX Text

WITHIN THE WORK AREA.

AutoCAD SHX Text 4- ALL DEMOLISHED MATERIAL SHALL BE DISPOSED OFF SITE ON A REGULAR BASIS. ALL DISPOSAL AND RUBBISH REMOVAL ARE THE DEMOLITION'S

AutoCAD SHX Text

CONTRACTOR'S RESPONSIBILITY.

AutoCAD SHX Text 5- REMOVE ALL EXISTING ROOFING, FLASHING ETC. DOWN TO EXISTING DECKING. THE DECKING IS TO BE CLEANED, PATCHED, REPAIRED AND MADE

AutoCAD SHX Text

READY FOR THE INSTALLATION OF NEW ROOFING SYSTEM.

AutoCAD SHX Text 6- ALL AREAS (I.E. WALLS, WINDOWS, CURBING...) MARRED BY BIRD DROPPINGS ARE TO BE CLEANED AND PRIMED AND PAINTED.

AutoCAD SHX Text 7- ALL CORRODED METAL (I.E. ROOF VENTS, EXHAUST, CURBINGS, DUNNAGE, ETC...) IS TO BE CLEANED, PRIMED AND PAINTED.

AutoCAD SHX Text 8- REMOVE ALL EXISTING ROOF DRAINS AND REPLACE WITH NEW CAST IRON DRAINS AND STRAINERS. LOWER DRAINS AS MUCH AS POSSIBLE TO ACHIEVE

AutoCAD SHX Text

REQUIRED ROOF SLOPE... ALL DRAINS TO BE TESTED FOR PROPER OPERATION.

AutoCAD SHX Text 9- ALL DEMOLITION WORK MUST BE DONE DURING NORMAL HOURS, UNLESS REQUIRED OTHERWISE.

AutoCAD SHX Text 10- CONTRACTOR IS RESPONSIBLE FOR REMOVING/DISCONNECTING ANY OBJECTS MOUNTED ON THE ROOF, LIKE CONDUITS, SOLAR PANELS, ANTENNAS, SATELLITE DISHES, ETC... TO ACCOMMODATE

AutoCAD SHX Text NEW WORK. RECONNECT, TEST AND RE-SECURE ALL ITEMS AFTER INSTALLATION OF THE NEW ROOF.

AutoCAD SHX Text

%%UGENERAL CONTRACTOR NOTES:

AutoCAD SHX Text 1- THE GENERAL CONTRACTOR SHALL MEET WITH THE BUILDING OWNER PRIOR TO SUBMITTING A BID ON THIS PROJECT

AutoCAD SHX Text AND AT OTHER TIMES AS REQUIRED BY THE OWNER TO VERIFY AND REVIEW REGULATIONS AND BUILDING PROCEDURES.

AutoCAD SHX Text 2- THESE NOTES, SPECIFICATIONS AND DRAWINGS ARE ONLY TO DEPICT GRAPHICALLY THE GENERAL NATURE OF THE WORK AND

AutoCAD SHX Text SHOW THE GENERAL EXTENT OF THE PROJECT, AND DO NOT NECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR

AutoCAD SHX Text FULL PERFORMANCE AND COMPLETION OF THE REQUIREMENTS, NOR DO THEY SHOW ALL OF THE BASIS OF THE GENERAL

AutoCAD SHX Text SCOPE INDICATED OR DESCRIBED. THE CONTRACTOR SHALL FURNISH ALL WORK ITEMS REQUIRED FOR THE PROPER EXECUTION

AutoCAD SHX Text

AND COMPLETION OF THE WORK.

AutoCAD SHX Text 3- NO GUARANTEE IS MADE AS TO THE GENERAL CONDITIONS OF EXISTING CONSTRUCTION. THE DEGREE OF VARIANCE FROM PLUMB, AutoCAD SHX Text LEVEL, FLAT, AND/OR SOUND SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO ANY CONSTRUCTION. ARCHITECT SHALL BE

AutoCAD SHX Text NOTIFIED PRIOR TO CONSTRUCTION IF VARIANCE WILL EFFECT DESIGN INTENT OR COMPLIANCE WITH THE QUALITY STANDARDS HEREIN.

AutoCAD SHX Text 4- THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE TO REPAIR OR REPLACE ANY DAMAGED BASE BUILDING AREAS CAUSED AS A

AutoCAD SHX Text

RESULT OF WORK PERFORMED IN CONNECTION WITH THIS PROJECT.

AutoCAD SHX Text 5- THE CONTRACTOR SHALL VISIT THE SITE OF WORK AND COMPARE WITH THE DRAWINGS. BY PERFORMING THE SITE VISIT, THE CONTRACTOR

AutoCAD SHX Text HAS AGREED THAT HE/SHE HAS INVESTIGATED AND IS FULLY INFORMED AS TO THE CONDITIONS AND MATERIALS TO BE RENOVATED AS TO

AutoCAD SHX Text CHARACTER, QUALITY AND QUANTITIES OF WORK TO BE PERFORMED AND MATERIALS TO BE FURNISHED AND AS TO THE REQUIREMENTS

AutoCAD SHX Text

ON THE PLANS.

AutoCAD SHX Text 6- THE CONTRACTOR IS RESPONSIBLE FOR ALL PERMIT FEES, COSTS FOR LICENSES, CERTIFICATE, SERVICE CHARGES, TAXES, INSURANCE

AutoCAD SHX Text

REQUIREMENTS, ETC. ASSESSED BY ANY GOVERNMENTAL AGENCY OR UTILITIES COMPANY.

AutoCAD SHX Text 7- IT IS THE INTENT OF THE COR THAT ALL WORK BE IN CONFORMANCE WITH AUTHORITIES HAVING JURISDICTION OVER THIS TYPE OF

AutoCAD SHX Text

WORK AND OCCUPANCY.

AutoCAD SHX Text 8- ALL CONTRACTORS SHALL PERFORM THEIR WORK IN COMPLIANCE WITH THE APPLICABLE CODE AND ALL APPLICABLE VA STANDARDS, AutoCAD SHX Text

FEDERAL LAWS, AND OTHER APPLICABLE CODES AND REGULATIONS.

AutoCAD SHX Text 9- THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING AND PAYING FOR THE COST OF ALL INSPECTIONS AND TESTS REQUIRED TO

AutoCAD SHX Text

IMPLEMENT THE DOCUMENTS OR AS REQUIRED BY ANY GOVERNMENTAL AGENCY.

AutoCAD SHX Text 10- CONSTRUCTION BIDS SHALL BE SUBMITTED INCLUDING ANY AND ALL COSTS NECESSARY TO COMPLETE THE PROJECT IN ACCORDANCE WITH

AutoCAD SHX Text

THESE DOCUMENTS AND WITHIN A CONSTRUCTION SCHEDULE AGREED UPON BY THE OWNER.

AutoCAD SHX Text

%%UROOFING REPAIR GUIDELINES:

AutoCAD SHX Text 1- ONLY TRAINED ROOF INSTALLER FAMILIAR WITH THE PRODUCTS BEING USED SHOULD PERFORM THE INSTALLATION OF ROOFING

AutoCAD SHX Text

MATERIALS, FLASHING, ETC...

AutoCAD SHX Text 2- ADEQUATE PROVISIONS SHOULD BE MADE FOR THE PROPER PLASHING OF HVAC AND ELECTRICAL EQUIPMENT INCLUDING THEIR SERVICE

AutoCAD SHX Text

PIPING AND CONDUITS.

AutoCAD SHX Text 3- PERFORM ALL ROOF TOP WORK IN ACCORDANCE WITH NRCA AND MANUFACTURER DETAILS AND INSTRUCTIONS.

AutoCAD SHX Text 4- INSTALL FLASHING TO CONFORM TO STANDARDS SET FORTH IN THE SMACNA ARCHITECTURAL SHEET METAL MANUAL AND NRCA MANUAL. ALL

AutoCAD SHX Text ROOFTOP WORK (REMOVAL OF EXISTING ROOFING, INSTALLATION OF ROOFING MATERIALS, FLASHING, EQUIPMENT, ETC.) SHOULD BE PERFORMED

AutoCAD SHX Text

IN THE SAME DAY.

AutoCAD SHX Text 5- ALL WORK SHOULD BE PERFORMED IN A WAY THAT IT DOESN'T VOID THE EXISTING WARRANTY. AFTER WORK IS COMPLETED THE CONTRACTOR

AutoCAD SHX Text MUST ARRANGE FOR A FINAL INSPECTION WITH THE MANUFACTURER TO VERIFY WORK WAS DONE PER THEIR INSTRUCTION.

AutoCAD SHX Text 6- REMOVE NO MORE EXISTING ROOFING THAN WHAT CAN BE COVERED IN ONE DAY BY NEW ROOFING AND SO THAT BUILDING INTERIOR REMAINS

AutoCAD SHX Text WATERTIGHT AND WEATHERTIGHT. SEE DIVISION 07 SECTION 07 51 00 FOR NEW ROOFING REQUIREMENTS.

AutoCAD SHX Text

%%UCONSTRUCTION NOTES:

AutoCAD SHX Text 1- ALL ROOF DIMENSIONS SHALL BE FIELD VERIFIED PRIOR TO COMMENCEMENT OF WORK. WHERE FABRICATION IS REQUIRED, DIMENSION SHALL BE

AutoCAD SHX Text

VERIFIED PRIOR TO COMMENCEMENT OF SHOP DRAWINGS.

AutoCAD SHX Text

2- ALL ROOFS SHALL BE PITCHED AT 1/4" PER 1'0" MINIMUM.

AutoCAD SHX Text 3- ALL ROOF PENETRATIONS SHALL BE SEALED AS PER ROOF MANUFACTURER'S RECOMMENDATIONS USING ROOF MANUFACTURER'S SEALING DETAILS

AutoCAD SHX Text

AND MATERIALS.

AutoCAD SHX Text 4- IN AREA OF WORK IT IS THE CONTRACTOR'S RESPONSIBILITY TO PATCH AND REPAIR ALL EXISTING DAMAGES AND PREPARE SURFACES TO RECEIVE NEW

AutoCAD SHX Text

FINISHES OR WATERPROOFING AS PER MANUFACTURER'S RECOMMENDATIONS.

AutoCAD SHX Text

5- CONTRACTOR TO FIRE STOP ALL PENETRATIONS THROUGH RATED ASSEMBLIES.

AutoCAD SHX Text 6- CONTRACTOR TO MAINTAIN FREE AND UNOBSTRUCTED ACCESS AT ALL TIMES TO ALL EMPLOYEES AND PATIENTS, ALL EMERGENCY SERVICES AND FIRE, POLICE, AutoCAD SHX Text

AND ALL EMERGENCY RESPONSE FORCES IN ACCORDANCE WITH N.F.P.A.

AutoCAD SHX Text 7- CONTRACTOR TO PROVIDE FALL PROTECTION ACCORDING TO OSHA (I.E. TEMPORARY RAILINGS, HARNESS, ETC...).

AutoCAD SHX Text 8- CONTRACTOR MUST PROVIDE ALL HOT WORK PERMITS FOR ANY HOT WORK BEING DONE ON THE JOB. CONTRACTOR IS TO PERFORM AND SAFEGUARD ALL HOT

AutoCAD SHX Text WORK OPERATIONS IN ACCORDANCE WITH NFPA 241 AND NFPA 51B. COORDINATE WITH COR AND VA SAFETY ENGINEER FOR PROPER FORMS AND REQUIREMENTS.

AutoCAD SHX Text 9- ALL NEW WORK MUST BE DONE DURING NORMAL BUSINESS HOURS, UNLESS REQUIRED OTHERWISE.

AutoCAD SHX Text 10- THE REAR BUILDING ENTRANCE MUST NOT BE BLOCKED OR CLOSED OFF AT ANY TIME UNLESS IT IS APPROVED BY THE COR.

AutoCAD SHX Text 11- ALL MATERIAL DELIVERIES MUST BE DONE DURING NORMAL HOURS, WITH PRIOR EXPRESSED WRITTEN NOTICE, UNLESS OTHERWISE NOTED.

AutoCAD SHX Text 12- IF CRANE IS BEING USED, CONTRACTOR SHALL PROVIDE ALL NECESSARY DOCUMENTS FOR VA APPROVAL.

AutoCAD SHX Text 13- CONTRACTOR MUST HAVE A MINIMUM OF AT LEAST FIVE (5) YEARS EXPERIENCE OF INSTALLATION OF LIQUID APPLIED ROOFING SYSTEM AND MUST HAVE FINISHED

AutoCAD SHX Text AT LEAST FIVE (5) OR MORE PROJECTS ON INSTALLATION OF LIQUID APPLIED ROOFING SYSTEM... SUBMIT ALL QUALIFICATIONS TO VA FOR APPROVAL BEFORE STARTING.

AutoCAD SHX Text 14- THE NEW ROOFING SYSTEM MUST HAVE A 20 YEAR WARRANTY. SUBMIT ROOF WARRANTY CERTIFICATE TO COR AFTER ROOF IS COMPLETED.

AutoCAD SHX Text 15- CONTRACTOR IS RESPONSIBLE OF REMOVING/DISCONNECTING ANY ROOF OBJECT (I.E. ELECTRICAL CONDUIT, SATELLITE DISH, SOLAR PANELS, ETC...) TO ACCOMMODATE THE NEW WORK.

AutoCAD SHX Text RECONNECT, TEST AND RE-SECURE ALL NECESSARY OBJECTS AFTER THE NEW ROOF IS INSTALLED.

AutoCAD SHX Text %%UROOF PLAN: (ALL TO BE DONE ACCORDING TO MANUFACTURER'S RECOMMENDATION AND DETAILS)

AutoCAD SHX Text

1- REPLACE CRACKED AND/OR DAMAGED COPING STONES, IF APPLICABLE.

AutoCAD SHX Text 2- REMOVE & REPLACE ALL EXISTING ASSOCIATED MATERIALS AND/OR SYSTEMS REQUIRED TO BE REMOVED FOR INSTALLATION OF NEW ROOF.

AutoCAD SHX Text

3- REPLACE FLASHING AT EXISTING PLUMBING VENTS.

AutoCAD SHX Text

4- REPLACE EXISTING ROOF DRAINS.

AutoCAD SHX Text

5- REPLACE FLASHING AT EXISTING ROOF EXHAUST FAN.

AutoCAD SHX Text

6- REPLACE FLASHING AT EXISTING EQUIPMENT PAD, IF APPLICABLE.

AutoCAD SHX Text

7- EXISTING STEAM PIPE TO REMAIN, IF APPLICABLE.

AutoCAD SHX Text

8- REPLACE FLASHING AT EXISTING ROOF HATCH, IF APPLICABLE.

AutoCAD SHX Text

9- REPLACE FLASHING AT EXISTING STEAM PIPES, IF APPLICABLE.

AutoCAD SHX Text 10- SCRAPE, CLEAN AND INSTALL SEALANT IN ALL COPING STONES TRANSVERSE JOINTS, IF APPLICABLE.

AutoCAD SHX Text

11- REPLACE BASE AND CAP FLASHING AT EXISTING BRICK COLUMNS.

AutoCAD SHX Text

12- REPLACE BASE AND CAP FLASHING AT BULKHEAD WALL.

AutoCAD SHX Text 13- INSTALL NEW PAINTED WALKWAYS, WHERE INDICATED ON DRAWINGS AND APPROVED BY COR.

AutoCAD SHX Text

14- EXISTING SCUPPER TO REMAIN, IF APPLICABLE.

AutoCAD SHX Text 15- NEW EXPANSION JOINT AT PARAPET WALL, EXTEND 12 ROWS OF BRICK (APPROX. 2'8"MIN.

AutoCAD SHX Text

BELOW BOTTOM OF COPING STONES, IF APPLICABLE.

AutoCAD SHX Text 4- FALL PROTECTION PLAN MUST BE SUBMITTED AND APPROVED PRIOR TO COMMENCEMENT OF WORK.

AutoCAD SHX Text 2/21/20

AutoCAD SHX Text

REV A: ADDED RAILING, MODIFIED DETAILS

AutoCAD SHX Text

100% ISSUE FOR BID

AutoCAD SHX Text

100%%% ISSUE FOR BID

AutoCAD SHX Text 2/21/20

AutoCAD SHX Text

<REV A>

AutoCAD SHX Text

<REV A>

AutoCAD SHX Text

<REV A>

Sheets and Views
AE-103A Demolition-New Plan Notes- Bld 1 Roof- BID-Model

File details come from the government source that posted it. Updated .