This file is a Modification to a Previous Notice containing Responses to Requests for Information (RFIs) for a Department of Veterans Affairs architectural and engineering services solicitation. The solicitation (36C24126Q0518) seeks design services for Project 631-21-011 to build and install a new elevator tower at Building 25 on the VA Central Western Massachusetts Healthcare System Leeds Campus. The project requires all professional A/E Part One Services (Design Phase Type A & Type B) and Part Two Services (Construction Period Services Type C) to develop complete drawings, specifications, and cost estimates. Scope includes evaluating existing elevator pit slabs across multiple buildings, designing an elevator pit sump pump with oil interceptor, designing plumbing to sanitary sewer, conducting Section 106 Historical Submission Reports if the tower appearance differs from the conceptual design, and performing code compliance reviews against NFPA, ABAAS, and VA Design Manuals. The NAICS code is 541330 (Engineering Services) with a small business size standard of $25.5M.

The RFI responses address three key questions: (1) the conceptual design firm, Apogee Consulting Group, and its subsidiaries are not precluded from submitting qualifications; (2) the requirement for minimum two comprehensive exterior historical renovation design projects completed within the Commonwealth of Massachusetts cannot be waived due to state-specific review procedures and regulatory requirements, with firms required to demonstrate direct experience with historical reviews and preservation processes; and (3) CPARS evaluations and Past Performance Questionnaires (PPQs) are exempt from the 65-page submission limit. The response deadline is December 7, 2026, at 4:00 PM Eastern Time. The contracting office is located at 421 North Main Street, Leeds, MA 01053-9764, with Point of Contact Contracting Officer Brian Kelly (Brian.Kelly@va.gov, 413-584-4040).

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Modification to a Previous Notice Modification to a Previous Notice

SUBJECT*
631-21-011 Build Elevator Tower for Building 25 Responses to RFIs Received

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
01053-9764
SOLICITATION NUMBER*
36C24126Q0518
BASE NOTICE TYPE
S
RESPONSE DATE/TIME/ZONE
12-07-2026 4:00PM EASTERN TIME, NEW YORK, USA
ARCHIVE
99 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N
SET-ASIDE
SBA
PRODUCT SERVICE CODE*
C1AZ
NAICS CODE*
541330
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

Network Contracting Office 1

VA CENTRAL WESTERN MASSACHUSETTS HCS

421 North Main Street Leeds MA 01053-9764

POINT OF CONTACT*

Contracting Officer Brian Kelly Brian.Kelly@va.gov 413-584-4040

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS
Brian.Kelly@va.gov
EMAIL DESCRIPTION
Brian.Kelly@va.gov

DESCRIPTION

Project 631-21-011 Building 25 Elevator Design Responses to RFIs Received

1. Will the Concept Design A/E firm, Apogee Consulting Group, and/or it’s subsidiaries be precluded from submitting qualifications specifically in regard to this solicitation?

VA Response: Parties who aided with the conceptual design are not precluded from submitting qualifications.

1. Historical Renovation Experience: The SOW requires a minimum of two (2) comprehensive design projects involving exterior historical renovations completed within the Commonwealth of Massachusetts. Would the VA consider removing the geographic restriction to allow relevant historic renovation experience completed in other states? This would broaden the pool of qualified firms while maintaining the requirement for demonstrated historic preservation expertise.

VA Response: The requirement cannot be waived or otherwise alleviated. Experience within the Commonwealth of Massachusetts is necessary due to geographical requirements because historical renovation projects do involve state-specific review procedures, regulatory requirements, and coordination with local preservation authorities. Firms shall therefore provide examples of completed projects demonstrating direct experience with historical reviews, including the applicable review processes, agency coordination, and preservation requirements.

1. Page Limitations: Could you clarify whether CPARS evaluations and Past Performance Questionnaires (PPQs) will count toward the overall 65-page submission limit, or if these documents are exempt?

VA Response: CPARS and PPQs do not count towards the 65-page limit.