About this file

This is a Questions and Answers document for solicitation 36C24125R0025, which clarifies requirements for Architect/Engineering services to replace underground storage tanks at VA facilities in West Haven and Newington, CT. The Q&A confirms that offerors should demonstrate experience in underground storage tank replacement rather than laboratory renovations. It specifies the tank requirements: At Newington - two 6,000-gallon and one 4,000-gallon double wall FRP tanks near Buildings 2W, 2E and 3; at West Haven - one 12,000-gallon double wall FRP tank near Building 38.

The document amends the SF330 submission deadline to February 20, 2025 at 11:00 AM EST and includes an additional site plan document for West Haven. This is a total SDVOSB set-aside under NAICS 541330 with a $25.5M size standard. The estimated construction magnitude is $1-5 million. The work involves removing and replacing existing diesel fuel storage tanks to address environmental issues identified during recent inspections.

View the file

Other files for this federal contract opportunity

Other files attached to C1DA--689-25-112, AE Replace Underground Storage Tanks, newest first.
File Type Posted
S06 Site EHRM Utility Boring Plan.pdf PDF
S06 Statement of Work 689-25-112 UST Replacements.docx DOCX document
S06 WH M4site UST Plan.pdf PDF
S06 Past Performance Questionnairre.docx DOCX document
S06 Site West Haven-MASTER-utility plan.pdf PDF
36C24125R0025_4.docx DOCX document
S06 08750 Newington W-1 Site.pdf PDF
P11 WH M4site UST Plan.pdf PDF
36C24125R0025_1.docx DOCX document
P09 Past Performance Questionnairre.docx DOCX document
S02 VA Notice of Limitations on Subcontracting.docx DOCX document
Site West Haven-MASTER-utility plan.pdf PDF
08750 Newington W-1 Site.pdf PDF
Site EHRM Utility boring plan.pdf PDF
P09_SOW_689-25-112 UST Replacements.docx DOCX document
Show all 15

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Modification to a Previous Notice Modification to a Previous Notice

SUBJECT*
689-25-112, AE Replace Underground Storage Tanks Requests for Specialized Experience Responses to RFI's

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
02301
SOLICITATION NUMBER*
36C24125R0025
BASE NOTICE TYPE
S
RESPONSE DATE/TIME/ZONE
02-20-2025 11:00 EASTERN TIME, NEW YORK, USA
ARCHIVE
99 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N
SET-ASIDE
SDVOSBC
PRODUCT SERVICE CODE*
C1DA
NAICS CODE*
541330
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

VA Connecticut Healthcare System Contracting Officer (90C) 950 Campbell Ave West Haven, CT 06516

POINT OF CONTACT*

Contract Specialist Cecilia Antwi cecilia.antwi@va.gov 774-826-3970

PLACE OF PERFORMANCE

ADDRESS

POSTAL CODE

COUNTRY

ADDITIONAL INFORMATION

AGENCY’S URL
https://www.va.gov
URL DESCRIPTION
https://www.va.gov
AGENCY CONTACT’S EMAIL ADDRESS
cecilia.antwi@va.gov
EMAIL DESCRIPTION
cecilia.antwi@va.gov

DESCRIPTION

Question 1: Evaluation criterion 2 states that offerors must demonstrate relevant experience in laboratory renovations, new laboratory design, and / or existing electrical load center renovations. Is this statement correct, given that the subject project is for replacement of underground storage tanks?

The three (3) A-E Design Services projects selected by the A-E Firm should best illustrate the relevant team experience similar in the scope and the nature of the Electrical Deficiencies, Phase 3 project. Said narrative that comprises of the three (3) most relevant A-E Design Services projects should indicate Government experience or private sector experience on existing laboratory renovations, new laboratory design, and/or existing electrical load center renovations, including switchgear, distribution switchgear, and buss duct replacements/upgrades, similar in size, scope, and complexity.

VA Response: Please show evidence of experience in replacement of underground storage tanks.

Question 2: On 36C24125R0025 what size tanks and types are you looking for?

VA Response:

Newington by nearby Building number

· 2W, 4000-gallon, Double Wall FRP

· 2E, 6000-gallon, Double Wall FRP

· 3, 6000-gallon, Double Wall FRP West Haven by nearby Building number

· 38, 12000-gallon, Double Wall FRP

Submission date for SF330 amended: All SF 330 submissions shall be submitted by February 20, 2025 at 11AM EST.

Amendment also includes WH M4Site UST Plan as attached.

See attached document: P11 WH M4site UST Plan.

*= Required Field
Modification to a Previous Notice

Modification to a Previous Notice

File details come from the government source that posted it. Updated .