S06 Attachment HazMat Report Newington.pdf

PDF 12 MB Posted

Attached to
J044--Steam Trap Replacements, West Haven and Newington Federal contract opportunity
Solicitation number
36C24122B0010
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 1

About this file

This solicitation from the Department of Veterans Affairs seeks proposals to replace steam traps at facilities in West Haven and Newington, Connecticut. Offerors are invited to submit bids for J044--Steam Trap Replacements, West Haven and Newington by February 15, 2023 to replace failing steam traps and associated components. The solicitation number is 36C24122B0010, and the IFB and attachment S06 provide further details on the scope of work. Proposals should address pricing and schedules to complete replacement of an estimated 150 failing steam traps across the two locations.

View the file

Other files for this federal contract opportunity

Show all 15

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VOLUME II

ASBESTOS CONTAINING MATERIAL &

LEAD CONTAINING PAINT

SURVEY REPORT

BUILDING 1

VISN 1

Newington VA Medical Center

555 Willard Avenue Newington, Connecticut

Project No. 2009023.005

May 31, 2011

5 Alfred Circle Bedford, MA 01730-2318

Telephone: (781) 275-6050 Toll Free: (800) 877-6050 Facsimile: (781) 275-5651 info@mabbett.com www.mabbett.com

© 2011, Mabbett & Associates, Inc.

mailto:info@mabbett.com http://www.mabbett.com/

Newington VAMC - Building 1 May 2011 ©2011, Mabbett & Associates, Inc. Page i Survey Report Newington Building 1_5-11_Final.doc

ACKNOWLEDGMENT

This Asbestos Containing Materials (ACM) and Lead Containing Paint (LCP) Building Survey Report was prepared for the Veterans Affairs (VA) New England Healthcare System (VISN 1) in accordance with an established scope of work as defined in Contract Number VA241-P-1653. The information presented herein is based on the facts and information conveyed to or received by the Mabbett & Associates, Inc. (M&A) Team during the preparation of this report. If any of the information provided to M&A that was used in preparing this report is incorrect, incomplete, or subject to change, M&A would wish to alter its opinion(s) accordingly. In addition, the professional opinions and information contained in this report are based solely on the requirements of the applicable regulations and technical data as known to M&A as of the date of this report and considered applicable to this report.

This individual building report from Volume II which contains building specific lead and asbestos findings is part of the Comprehensive VAMC Lead and Asbestos Survey Report consisting of:

Volume I - General

Chapter 1 - Introduction and Executive Summary Chapter 2 - Asbestos Operations & Maintenance (O&M) Manual Chapter 3 - Asbestos Containing Materials (ACM) Survey Tables Chapter 4 - Lead Containing Paint Survey Tables

Volume II – Individual Building Reports

Individual Building Reports Chapters including:

• Cover page with building number

• Building narrative summary

• Floor plans

• Relevant asbestos findings for the building

• Relevant lead containing paint findings for the building

• Relevant photos

Volume III – Appendices and Supporting Data

Appendix A - Asbestos Laboratory Analysis Reports and Laboratory Certifications Appendix B - Inspector Field Data Sheets/Chains-of-Custody Appendix C - Personnel Certifications & Licenses Appendix D - XRF Performance Characteristics/Calibration Records Appendix E - Lead Laboratory Analysis Reports and Laboratory Certifications (If Applicable)

Volume IV – HUD Residential LBP Reports (If Applicable)

©2011, Mabbett & Associates, Inc. Page ii Survey Report Newington Building 1_5-11_Final.doc

This report was prepared by the following Mabbett & Associates, Inc. team personnel:

ENVIROMED SERVICES, INC.

John Luby Project Manager EnviroMed Services, Inc.

Connecticut Asbestos Inspector 000281 Connecticut Management Planner 000281

This report has been reviewed and approved by:

MABBETT & ASSOCIATES, INC.

Robert K. McKinley, MPH, CIH, LIH Director of Industrial Hygiene Services

©2011, Mabbett & Associates, Inc. Page iii Survey Report Newington Building 1_5-11_Final.doc

TABLE OF CONTENTS

Description Page

1.0 INTRODUCTION & EXECUTIVE SUMMARY

2.0 BUILDING DESCRIPTION

3.0 ASBESTOS SURVEY

3.1 Sampling Methodology

3.2 Analytical Methodology

3.3 Summary of Asbestos Containing Materials (ACM) Findings

4.0 LEAD SCREENING SURVEY

4.1 Screening Survey Methodology

4.2 Summary of Lead Screening Survey Findings

5.0 LIMITATIONS

6.0 CLOSING REMARKS

6.1 Asbestos

6.2 Lead Containing Paint

Tables Table 1 – Specific Inaccessible Areas Table 2 – Summary of Positive ACM Samples Table 3 – Summary of Positive XRF Measurements Table 4 – Summary of ACM Building Results, including negative results.................. Appendix A Table 5 – Summary of XRF Measurements............................................................... Appendix B

Figures Figure 1 – Asbestos Survey Summary Plan – Building 1 - First Floor Figure 2 – Asbestos Survey Summary Plan – Building 1 - Second Floor Figure 3 – Asbestos Survey Summary Plan – Building 1 - Third Floor Figure 4 – Asbestos Survey Summary Plan – Building 1 - Fourth Floor Figure 5 – Asbestos Survey Summary Plan – Building 1 - Fifth Floor Figure 6 – Asbestos Survey Summary Plan – Building 1 - Attic/Cupola Figure 7 – Lead Screening Survey Summary Plan – Building 1 - First Floor Figure 8 – Lead Screening Survey Summary Plan – Building 1 - Second Floor Figure 9 – Lead Screening Survey Summary Plan – Building 1 - Third Floor Figure 10 – Lead Screening Survey Summary Plan – Building 1 - Fourth Floor Figure 11 – Lead Screening Survey Summary Plan – Building 1 - Fifth Floor Figure 12 – Lead Screening Survey Summary Plan – Building 1 - Attic/Cupola

Appendices Appendix A – Table 4, Summary of ACM Building Result Appendix B – Table 5, Summary of XRF Measurements Appendix C – Representative Photographs of ACM Appendix D – Representative Photographs of Non-Intact Lead Containing Paint

©2011, Mabbett & Associates, Inc. Page 1 of 18 Survey Report Newington Building 1_5-11_Final.doc

1.0 INTRODUCTION & EXECUTIVE SUMMARY

Mabbett and Associates, Inc. (M&A), with EnviroMed Services, Inc. (EnviroMed) as sub-contractors, performed surveys for suspect asbestos containing building materials (ACM) and screenings of suspect lead containing paint (LCP) surfaces utilizing an X-Ray Fluorescence (XRF) analyzer. Surveys were performed of selected buildings at the VA Medical Center (VAMC) located at 555 Willard Avenue, Newington, CT, under Contract VA241-P-1653. A complete list of buildings surveyed is in Volume I of this report. Site survey work was performed during May, 2010, by appropriately credentialed personnel as required. Collected suspect ACM samples were submitted to a certified analytical laboratory for asbestos analysis by polarized light microscopy (PLM) using positive stop methodology and transmission electron microscopy (TEM) where indicated. When necessary, paint chip samples were collected and submitted to a certified analytical laboratory for lead content analysis using atomic absorption spectroscopy. The survey effort involved the collection of the following samples, resulting in the following conclusions:

• 563 bulk samples for suspect ACM were collected in this building.

• Based on laboratory analysis of suspect ACM, 62 of the collected samples contained asbestos greater than 1%.

• 778 XRF analyzer measurements of building surfaces were taken in this building.

• 199 of the XRF measurements revealed concentrations of lead that exceeded

0.1 mg/cm2.

This building report consists of a summary of findings, floor plans indicating positive sample locations, detailed analytical findings for the specific surveyed building materials, and photos of identified ACM. In addition, photos of lead containing paint greater than 1.0 mg/cm2 and in an other than intact condition, when observed, were provided. Laboratory certificates of analysis and field data sheets for this building report are available in Volume III of the Comprehensive VAMC Lead and Asbestos Survey Report.

2.0 BUILDING DESCRIPTION

According to information provided by the VAMC Office of Facilities Management and observations made by the M&A team at the time of the survey, Building 1 was a six-story Ambulatory Care Building built in 1930 and occupied approximately 90,750 square feet.

3.0 ASBESTOS SURVEY

3.1 Sampling Methodology

A visual screening inspection was conducted by state licensed asbestos inspectors throughout the building to identify locations of suspect ACM. Only areas that were accessible during the field work phase were inspected. Every effort was made during the initial field survey work to access areas as necessary to complete the survey. However, if any areas remained inaccessible to the survey team, they are indicated in Table 1 below.

©2011, Mabbett & Associates, Inc. Page 2 of 18 Survey Report Newington Building 1_5-11_Final.doc

Table 1 – Specific Inaccessible Areas

Newington VA Medical Center, Building 1

Building Floor Room No.

Reason Area Was Inaccessible and Survey Impacts, If Applicable

There were no inaccessible areas identified during this survey.

Other general areas that were inaccessible or where the survey was limited to visual observation only are identified below:

• Within walls • Within fire doors

• Enclosed pipe/duct chases • Inside mechanical equipment/ductwork

• Above fixed drywall or plaster ceilings

Due to these access restrictions, ACM surveys should be performed prior to any proposed renovations or maintenance involving inaccessible areas.

Bulk samples were collected of suspect ACM in accordance with US Environmental Protection Agency (EPA) Asbestos Hazard and Emergency Response Act (AHERA) and VISN 1 approved M&A VISN 1 Survey Program Standard Operating Procedure (SOP). Roofing materials were not sampled unless otherwise indicated in order to maintain applicable warranties. Bulk suspect ACM sampling was conducted according to the following sampling plan:

(a) Surfacing material:

(1) At least three bulk samples shall be collected from each homogeneous area that is 1,000 ft2 or less.

(2) At least five bulk samples shall be collected from each homogeneous area that is greater than 1,000 ft2 but less than or equal to 5,000 ft2.

(3) At least seven bulk samples shall be collected from each homogeneous area that is greater than 5,000 ft2.

(b) Thermal system insulation:

(1) At least three bulk samples shall be collected from each homogeneous area of thermal system insulation.

(2) At least one bulk sample shall be collected from each homogeneous area of patched area of thermal system insulation.

(3) Sufficient samples shall be collected from elbows and fittings to determine if it contains

ACM.

(4) Bulk samples shall not be collected from any homogeneous area where the state licensed asbestos inspector determined that the thermal system insulation is fiberglass, foam glass, rubber, or other non-ACM.

©2011, Mabbett & Associates, Inc. Page 3 of 18 Survey Report Newington Building 1_5-11_Final.doc

(c) Miscellaneous material:

(1) At least one bulk sample shall be collected from each homogeneous area that is less than 100 ft2.

(2) At least three bulk samples shall be collected from each homogeneous area that is greater than 100 ft2.

3.2 Analytical Methodology

The collected bulk samples were submitted under chain of custody procedures to EnviroMed Services, Inc. (EnviroMed) of Meriden, CT for polarized light microscopy (PLM) analysis of bulk materials via EPA 600/R-93/116 Method. If applicable, sample results that revealed trace concentrations of asbestos by PLM were re-analyzed using transmission electron microscopy (TEM) analysis. EnviroMed is accredited by the American Industrial Hygiene Association (AIHA) and participates in the National Voluntary Laboratory Accreditation Program (NVLAP Lab Code 200858-0). Duplicate bulk samples were submitted to ProScience. ProScience is accredited by the American Industrial Hygiene Association (AIHA) and participates in the National Voluntary Laboratory Accreditation Program (NVLAP Lab Code 200090-0). A summary table containing the duplicate bulk sample results is provided in Volume I, Table 5. Copies of the laboratory accreditations are included in Volume III of the Comprehensive VAMC Lead and Asbestos Survey Report.

Bulk sample results are summarized in Table 4 – Summary of ACM Building Results. The EPA, Occupational Safety and Health Administration (OSHA), and the State of Connecticut Department of Public Health (DPH) define any material that contains greater than one percent (>1%) asbestos as being an ACM. As such, the analytical laboratory identified bulk samples as positive for asbestos that met the regulatory criteria of greater than one percent (>1%) asbestos.

3.3 Summary of Asbestos Containing Materials (ACM) Findings

3.3.1 Data Tables, Laboratory Results, and Field Notes

Collected bulk samples confirmed by the analytical laboratory to contain >1% asbestos are listed in Table 2 - Summary of Positive ACM Samples. Samples analyzed by PLM containing trace levels of asbestos, defined as ≤ 1%, are listed in Table 4 with the TEM analysis results. Volume III of the Comprehensive VAMC Lead and Asbestos Survey Report includes copies of the laboratory certificates of analysis (including duplicate samples) and Inspector Field Data Sheets.

©2011, Mabbett & Associates, Inc. Page 4 of 18 Survey Report Newington Building 1_5-11_Final.doc

Table 2 - Summary of Positive ACM Samples

Sample No.

Sample Location

ACM

Location

Description of Material

Percent and Type of Asbestos

Condition Estimated Quantity

VISN 1

RISK

Hazard Category

1-4*

18A

Exterior Exterior Gray Exterior Window Sill

Caulk

15% Chrysotile Good 800 LF 4

21B 21C

4th Fl Stairway #3 2nd Fl Stairway

#1

Stair #1, Stair #3

Glue for Red Rubber Stair

Treads

2% Chrysotile Good 500 SF 4

22B 22C

4th Fl Stairway #3 5th Fl Stairwell #3

4th Fl Stairway #3

5th Fl Stairwell #3

12” Beige w/Black

Streaks Vinyl Floor Tile

3% Chrysotile Good 200 SF 4

23A 23B 23C

4th Fl Stairway #3 4th Fl Stairway #3 5th Fl Stairway #3

4th Fl Stairway #3

5th Fl Stairwell #3

Mastic for 12” Beige w/Black Streaks Vinyl

Tile

5% Chrysotile Good 200 SF 4

41A 41B 41C

4th Floor 1-405 4th Floor 1-405 4th Floor 1-405

1-405 Fire Door Core

10% Amosite

3% Chrysotile

Good 1 Door1 4

70A 70B 70C

4th Floor 1-411D 4th Floor 1-405 4th Floor 1-405

1-405, 1-411, 1-411D

Green Vinyl Sheet Flooring

3% Chrysotile Good 413 SF 4

73A 73B 73C

4th Floor 1-405 4th Floor 1-405

Exterior

1-405, 1-411, Exterior

Brown Mastic Associated w/Styrofoam Window Panels

6% Chrysotile Good 105 SF 4

75A 75B 75C

4th Floor 1-410 4th Floor 1-410 4th Floor 1-410

1-410 Brown Wall Hole Patch

7% Chrysotile Good 35 SF 4

77A 77B 77C

4th Floor 1-400 4th Floor 1-400 4th Floor 1-400

1-400, IN-224,

IN-224A, IN-

225, IN-227,

1st Fl C1-4

TSI Pipe End

15% Chrysotile

3% Amosite

Good 6 LF 4

79A 79B 79C

4th Floor 1-402 4th Floor 1-402 4th Floor 1-402

1-402 Tan Caulking on Radiator

3% Chrysotile Good 1 SF 4

©2011, Mabbett & Associates, Inc. Page 5 of 18 Survey Report Newington Building 1_5-11_Final.doc

Table 2 - Summary of Positive ACM Samples Newington VA Medical Center, Building 1

Sample No.

Sample Location

ACM

Location

Description of Material

Percent and Type of Asbestos

Condition Estimated Quantity

VISN 1

RISK

Hazard Category

1-4*

80A 80B 80C

4th Floor 1-402 4th Floor 1-402 4th Floor 1-402

IN-224A, IN-

214, 1-345, 1-

405, 1-402, 1-400, 1-411D, IS-

272, IS-274,

IS-271, IS-

278, IS-273,

IS-266A, IS-

266, IS-280,

IS-264, IS-

262, IS-281,

IS-279, IS-

277, IS-275,

IS-269, IS-

267, IS-265,

IS-261B, IS-

261, IC-243,

IC-246, IC-

245, IC-244,

IN-227, 2nd Fl.

Stair 1, IN-225A, IN-

225, IN-219,

2nd Fl C2-4, IN-222, IN-215, IN-224

Air Cell Paper Backing at

Steel Radiator Panel

40% Chrysotile Good 945 SF 4

81A 81B 81C

4th Floor 1-402 4th Floor 1- 402 4th Floor 1-402

4th Floor 1-402 Rope Gasket Material

15% Chrysotile Good 5 LF 4

91A 91B 91C

Northend Attic Northend Attic Northend Attic

Northend Attic Mastic Seam Sealer

3% Chrysotile Good 250 LF 4

98A 98B 98C

Attic/Cupola Attic/Cupola Attic/Cupola

Attic/Cupola Interior Window

Cupola Putty

2% Chrysotile Good 100 LF 4

102A Attic Compressor Room

Center Attic, Attic

Compressor Rm, H20

Meter Room

Attic Ceiling Base Coat

Plaster

2% Chrysotile Good 2700 SF 4

112A 112B 112C

2nd Fl Corridor C2-1

2nd Fl Corridor C2-1

2nd Fl Corridor C2-1

C2-1 Glue Dots 3% Chrysotile Good 325 SF 4

©2011, Mabbett & Associates, Inc. Page 6 of 18 Survey Report Newington Building 1_5-11_Final.doc

Table 2 - Summary of Positive ACM Samples Newington VA Medical Center, Building 1

Sample No.

Sample Location

ACM

Location

Description of Material

Percent and Type of Asbestos

Condition Estimated Quantity

VISN 1

RISK

Hazard Category

1-4*

117A 1st Fl Corridor C1-5

1st Fl– All Rooms

2nd Fl– All Rooms

3rd Fl– All Rooms

4th Fl– All Rooms

5th Fl– All Rooms

Wall Plaster Skim Coat

3% Chrysotile Good 186,000

SF 4

121C 1S-168 168 Wallboard Compound

3% Chrysotile Good 288 SF 4

127A 127B 127C

IN 219

2nd Fl Corridor

C2-4 2nd Fl Corridor

C2-4

217, 219, C2- 4, C2-5

Black Mastic Under 12”x12”

Tan VFT

7% Chrysotile Good 1450 SF 4

130A 130B 130C

IN-213

IN-213

IN-213

IN-213

Black Felt Paper Under Yellow Gold vinyl sheet flooring

5% Chrysotile Good 325 SF 4

144A 144B 144C

IN-225

IN-225

IN-225

IN-225, IN-

225A

9”x9” Gray

VFT

5% Chrysotile Good 65 SF 4

145A 145B 145C

IN-225

IN-225

IN-225

IN-225, IN-

225A

9”x9” White

VFT

3% Chrysotile Good 65 SF 4

146A 146B 146C

IN-225

IN-225

IN-225

IN-225, IN-

225A

Black Border Tile

5% Chrysotile Good 45 SF 4

147A 147B 147C

IN-225

IN-225

IN-225

IN-225, IN-

225A

Black Mastic Under Tiles

10% Chrysotile Good 175 SF 4

152A 2nd Fl Corridor C2-4 C2-4 Wallboard

Compound 2%

Chrysotile Good 2000 SF 4

161A 161B 161C

IN-222

IN-222

IN-222

IN- 222

Black Mastic for 12” gray

VFT with mottle

7% Chrysotile Good 158 SF 4

170A 170B 170C

IC-243

IC-243

IC-244

IC-243, IC-244

12”x12” Cream VFT with Tan and Black Streaks

2% Chrysotile Good 543 SF 4

©2011, Mabbett & Associates, Inc. Page 7 of 18 Survey Report Newington Building 1_5-11_Final.doc

Table 2 - Summary of Positive ACM Samples Newington VA Medical Center, Building 1

Sample No.

Sample Location

ACM

Location

Description of Material

Percent and Type of Asbestos

Condition Estimated Quantity

VISN 1

RISK

Hazard Category

1-4*

171A 171B 171C

IC-243

IC-243

IC-244

IC-243, IC-244

Glue Under 12”x12”

Cream VFT with Tan and Black Streaks

8% Chrysotile Good 543 SF 4

175A 175B 175C

1N-111 1N-111 1N-111

1N-111

Gray Leveling Compound Under Red

Carpet

2% Chrysotile Good 386 SF 4

177A 177B 177C

1st Floor 106D 1st Floor 106D 1st Floor 106D

106D Blue Diamond Pattern Carpet

Glue

4% Chrysotile Good 235 SF 4

178A 178B 178C

1st Floor 1C-143 1st Floor 1C-143 1st Floor 1C-143

1C-143 White Flex Connector

25% Chrysotile Good 3 SF 4

Footnotes:

1 – Fire door core insulation is visible at the 1 door listed. All doors in the building should be assumed asbestos containing.

SF – Square Feet LF – Linear Feet CF – Cubic Feet

©2011, Mabbett & Associates, Inc. Page 8 of 18 Survey Report Newington Building 1_5-11_Final.doc

* The VISN 1 hazard assessment scale 1 – 4 is a relative indicator of the risk and need for response/remediation. (1) represents the highest priority (e.g. removal or encapsulation) where as a (4) represents the lowest priority (monitor as part of 6 month O&M program). The rating assigned by an Asbestos Management Planner, takes into account: condition, friable vs. non-friable, accessibility, occupancy (e.g. continuous, intermittent or occasional and patients/staff/visitors), potential for air erosion, potential for vibration damage, potential for disturbance / damage (e.g. exposed and in an accessible location), and potential for water damage.

3.3.2 Photographs

Representative photographs of identified ACM are provided in Appendix C of this report.

3.3.3 CADD Drawings

The location of each ACM sample and its abridged sample ID is shown on the CADD drawings in the Figures Section of this report. The sample ID on the drawings has been abridged (by excluding the individual room number from the full sample ID) for aesthetic purposes. Each positive ACM sample location is colored red and marked with an asterisk (*), while stop positives are marked with two asterisks (**). Collected bulk samples that were not positive are identified solely by the abridged sample ID. Building areas containing ACM have been indicated with hatching to identify the location of the identified ACM.

4.0 LEAD SCREENING SURVEY

4.1 Screening Survey Methodology

M&A completed a Lead Containing Paint Risk Analysis in accordance with the SOP and determined that a LCP screening survey was warranted in this building. The LCP screening survey was performed by trained lead inspectors/screeners meeting the qualifications outlined in the SOP. The screening survey measured lead concentrations in accessible building surfaces by using a Niton XLp 703A XRF (serial number 7712). The XRF instrument was calibrated at the frequency specified in the SOP.

4.2 Summary of Lead Screening Survey Findings

4.2.1 Data Tables

As specified by VISN 1, a description of XRF-screened painted interior and exterior building components containing lead at concentrations greater than 0.1 mg/cm2 have been included in Table 3 below:

©2011, Mabbett & Associates, Inc. Page 9 of 18 Survey Report Newington Building 1_5-11_Final.doc

Table 3 - Summary of Positive XRF Measurements above VISN1-Specified Threshold of >0.1 mg/cm2

Reading

No. Floor Location Substrate and Component Side Condition Color Results

(mg/cm2)

14 FOURTH 1-434

METAL DOOR

CASING South - C INTACT GRAY 0.19

73 FIFTH

WEST CENTER

STAIRWELL

METAL STAIR

NEWEL POST North - A INTACT BLUE 1.6

76 FIFTH

WEST CENTER

STAIRWELL

METAL STAIR

RISER North - A INTACT BLUE 0.5

78 FIFTH

WEST CENTER

STAIRWELL

METAL STAIR

STRINGER North - A INTACT BLUE 1.4

79 FIFTH

WEST CENTER

STAIRWELL PLASTER WALL West - D INTACT BLUE 1.4

83 FIFTH

WEST CENTER

STAIRWELL METAL RAILING North - A INTACT BLUE 2

85 FIFTH

WEST CENTER

STAIRWELL METAL RAILING North - A INTACT BLUE 1.2

89 FIFTH 1-511 PLASTER WALL West - D Not Intact-

POOR BLUE 1.2

91 FIFTH 1-511

CONCRETE

FLOOR West - D Not Intact-

POOR GRAY 1.4

93 FIFTH 1-511

METAL FIRE

SPRINKLER

PIPE West - D INTACT RED 0.4

101 FIFTH

WEST CENTER

STAIRWELL

PLASTER

CEILING North - A INTACT BLUE 0.11

103 FIFTH

WEST CENTER

STAIRWELL

METAL DOOR

CASING South - C INTACT GRAY 0.19

107 FIFTH

WEST CENTER

STAIRWELL

METAL

BASEBOARD East - B INTACT BLUE 1.5

108 FIFTH

WEST CENTER

STAIRWELL

METAL STAIR

BALUSTER North - A INTACT BLUE 0.4 109 FIFTH 1-522 PLASTER WALL East - B INTACT WHITE 0.3

114 FIFTH 1-519

METAL

WINDOW

CASING North - A INTACT WHITE 3.5

160 ATTIC ATTIC NORTH

WOOD

SUPPORT BEAM South - C Not Intact-

POOR GRAY 0.11

167 ATTIC ATTIC SOUTH METAL PIPE East - B Not Intact-

POOR SILVER 0.17

170 ATTIC ATTIC SOUTH

WOOD WINDOW

CASING East - B Not Intact-

POOR GREEN 3.4

177 ATTIC ATTIC SOUTH

WOOD WINDOW

CASING West - D Not Intact-

POOR GRAY 5.2

183 ATTIC ATTIC SOUTH

WOOD WINDOW

CASING East - B Not Intact-

POOR WHITE 2.2

184 ATTIC ATTIC SOUTH

WOOD WINDOW

CASING East - B Not Intact-

POOR WHITE 1.5

188 ATTIC ATTIC CENTER PLASTER WALL West - D INTACT GREEN 0.14 191 ATTIC ATTIC CENTER PLASTER WALL East - B INTACT GREEN 0.11

192 ATTIC ATTIC CENTER

METAL

ELECTRIC BOX

MOUNT West - D Not Intact-

POOR GRAY 0.21

©2011, Mabbett & Associates, Inc. Page 10 of 18 Survey Report Newington Building 1_5-11_Final.doc

Table 3 - Summary of Positive XRF Measurements above VISN1-Specified Threshold of >0.1 mg/cm2 Newington VA Medical Center, Building 1

Reading No. Floor Location Substrate and

Component Side Condition Color Results (mg/cm2)

194 ATTIC ATTIC CENTER

METAL STAIR

RISER West - D Not Intact-

POOR RED 0.13

195 ATTIC ATTIC CENTER

METAL STAIR

STRINGER West - D Not Intact-

POOR RED 0.15

201 ATTIC ATTIC CENTER PLASTER WALL North - A INTACT GREEN 0.6

202 ATTIC ATTIC CENTER

METAL STAIR

TREAD West - D Not Intact-

POOR RED 0.11

203 ATTIC ATTIC CENTER METAL LADDER West - D Not Intact-

POOR RED 3.1

205 ATTIC ATTIC CENTER

CONCRETE

LEDGE West - D Not Intact-

POOR RED 0.11

207 ATTIC ATTIC CENTER METAL HATCH West - D INTACT GREEN 4.3

209 ATTIC SIDE ROOM 1 PLASTER WALL East - B Not Intact-

POOR BEIGE 0.17

210 ATTIC SIDE ROOM 1

METAL

ELECTRIC BOX

MOUNT South - C INTACT GRAY 0.14

212 ATTIC SIDE ROOM 1 METAL TANK South - C Not Intact-

POOR SILVER 0.16

213 ATTIC SIDE ROOM 1 METAL MOTOR North - A Not Intact-

POOR GREEN 1.3

214 ATTIC SIDE ROOM 1 METAL DUCT North - A Not Intact-

POOR WHITE 0.14

215 ATTIC SIDE ROOM 1 METAL DUCT North - A Not Intact-

POOR WHITE 0.2

216 ATTIC SIDE ROOM 1 METAL MOTOR North - A INTACT RED 0.15

221 ATTIC SIDE ROOM 1

CONCRETE

COLUMN North - A INTACT WHITE 0.15

222 ATTIC SIDE ROOM 1

CONCRETE

COLUMN South - C INTACT WHITE 0.16 228 ATTIC SIDE ROOM 2 PLASTER WALL North - A INTACT BEIGE 0.19

229 ATTIC SIDE ROOM 2 PLASTER WALL South - C Not Intact-

POOR BEIGE 0.19

238 ATTIC

ELEVATOR MECH

RM

CONCRETE

FLOOR North - A INTACT GRAY 0.23

243 ATTIC

ELEVATOR MECH

RM

WOOD WINDOW

CASING West - D Not Intact-

POOR BEIGE 11

251 THIRD

SOUTHWEST

STAIRWELL METAL WALL North - A INTACT BLUE 1.1

252 THIRD

SOUTHWEST

STAIRWELLSOUTH

WEST STAIRWELL

METAL STAIR

HANDRAIL South - C INTACT BLUE 1.7

253 THIRD

SOUTHWEST

STAIRWELL

METAL STAIR

STRINGER North - A INTACT BLUE 0.4

254 THIRD

SOUTHWEST

STAIRWELL

METAL STAIR

RISER East - B INTACT RED 0.7

255 THIRD

SOUTHWEST

STAIRWELL

METAL

BASEBOARD West - D INTACT BLUE 0.8

256 THIRD

SOUTHWEST

STAIRWELL

METAL STAIR

BALUSTER North - A INTACT BLUE 0.24

©2011, Mabbett & Associates, Inc. Page 11 of 18 Survey Report Newington Building 1_5-11_Final.doc

Table 3 - Summary of Positive XRF Measurements above VISN1-Specified Threshold of >0.1 mg/cm2 Newington VA Medical Center, Building 1

Reading No. Floor Location Substrate and

Component Side Condition Color Results (mg/cm2)

257 THIRD

SOUTHWEST

STAIRWELL PLASTER WALL North - A INTACT BLUE 0.2

263 THIRD

SOUTHWEST

STAIRWELL

PLASTER

CEILING South - C INTACT WHITE 0.16

264 THIRD

SOUTHWEST

STAIRWELL

METAL

WINDOW

CASING West - D INTACT BLUE 5.3

265 THIRD

SOUTHWEST

STAIRWELL

METAL

WINDOW

SECURITY

GATE West - D INTACT WHITE 0.13

267 THIRD

WEST CENTER

STAIRWELL

METAL STAIR

RISER North - A INTACT BLUE 0.6

268 THIRD

WEST CENTER

STAIRWELL

METAL STAIR

NEWEL POST North - A INTACT BLUE 1.8

269 THIRD

WEST CENTER

STAIRWELL

METAL STAIR

BALUSTER North - A INTACT BLUE 0.29

270 THIRD

WEST CENTER

STAIRWELL

METAL

BASEBOARD North - A INTACT BLUE 1

271 THIRD

WEST CENTER

STAIRWELL

METAL STAIR

STRINGER North - A INTACT BLUE 0.3

272 THIRD

WEST CENTER

STAIRWELL PLASTER WALL South - C INTACT BLUE 1.4

273 THIRD

WEST CENTER

STAIRWELL PLASTER WALL West - D INTACT BLUE 1.3 298 THIRD 1-304A PLASTER WALL North - A INTACT WHITE 0.17

300 THIRD 1-304A

METAL FIRE

SPRINKLER

PIPE North - A INTACT RED 0.11 311 THIRD C3-4 PLASTER WALL North - A INTACT WHITE 1.4

314 THIRD 1-305

CONCRETE

LEDGE North - A INTACT WHITE 0.7

343 THIRD 1-345

METAL

RADIATOR West - D Not Intact-

POOR WHITE 6.7

353 THIRD C3-9 METAL PIPE East - B INTACT GRAY 0.22 357 THIRD C3-7 METAL HATCH West - D INTACT WHITE 0.26 379 SECOND STAIR #1 PLASTER WALL West - D INTACT BLUE 0.3

382 SECOND STAIR #1 PLASTER

CEILING

East - B INTACT WHITE 0.16

384 SECOND STAIR #1

METAL STAIR

NEWEL POST West - D INTACT BLUE 2

385 SECOND STAIR #1

METAL STAIR

RISER West - D INTACT BLUE 1.2

386 SECOND STAIR #1

METAL STAIR

BALUSTER West - D INTACT WHITE 0.3

387 SECOND STAIR #1

METAL STAIR

STRINGER West - D INTACT WHITE 0.4

389 SECOND STAIR #1

METAL DOOR

CASING South - C INTACT RED 0.24

©2011, Mabbett & Associates, Inc. Page 12 of 18 Survey Report Newington Building 1_5-11_Final.doc

Table 3 - Summary of Positive XRF Measurements above VISN1-Specified Threshold of >0.1 mg/cm2 Newington VA Medical Center, Building 1

Reading No. Floor Location Substrate and

Component Side Condition Color Results (mg/cm2)

391 SECOND STAIR #1

METAL

BASEBOARD East - B INTACT BLUE 1.1 392 SECOND STAIR #3 PLASTER WALL South - C INTACT BLUE 0.19

393 SECOND STAIR #3

PLASTER

CEILING West - D INTACT WHITE 0.6

394 SECOND STAIR #3

METAL

WINDOW

CASING West - D INTACT BLUE 2.7

396 SECOND STAIR #3

METAL

BASEBOARD West - D INTACT BLUE 0.9

397 SECOND STAIR #3

METAL STAIR

HANDRAIL West - D INTACT BLUE 0.9

398 SECOND STAIR #3

METAL STAIR

NEWEL POST West - D INTACT BLUE 1.2

399 SECOND STAIR #3

METAL STAIR

STRINGER West - D INTACT BLUE 0.16 401 SECOND STAIR #3 METAL PIPE East - B INTACT BLACK 0.4

402 SECOND STAIR #3

METAL STAIR

RISER East - B INTACT RED 0.9

403 SECOND STAIR #3

METAL STAIR

BALUSTER East - B INTACT BLUE 0.5 409 SECOND C2-1 PLASTER WALL South - C INTACT WHITE 1

411 SECOND C2-1

METAL

FIREHOSE

CLOSET South - C INTACT WHITE 0.3

415 SECOND 1C-245 PLASTER WALL North - A INTACT WHITE 0.4

434 SECOND 1C-241

METAL

RADIATOR North - A INTACT WHITE 0.4

435 SECOND 1C-241

WOOD WINDOW

CASING East - B INTACT WHITE 0.25

436 SECOND 1C-241

WOOD DOOR

CASING East - B INTACT WHITE 0.26

437 SECOND 1C-241

METAL

ELECTRIC BOX

MOUNT South - C INTACT GRAY 0.4

445 SECOND C2-4

CONCRETE

COLUMN West - D INTACT WHITE 2.3

446 SECOND C2-4

METAL

ELECTRIC BOX

MOUNT East - B INTACT WHITE 0.26 449 SECOND C2-4 PLASTER WALL West - D INTACT WHITE 0.2

458 SECOND 1S-278

PLASTER

WINDOW SILL East - B Not Intact-

POOR WHITE 0.3

470 SECOND 1S-273

PLASTER

WINDOW WELL North - A Not Intact-

POOR BLUE 1.5

473 SECOND 1S-269

PLASTER

WINDOW SILL West - D Not Intact-

POOR

YELLO

W 0.15

477 SECOND 1S-281

PLASTER

WINDOW SILL South - C Not Intact-

POOR WHITE 0.24

©2011, Mabbett & Associates, Inc. Page 13 of 18 Survey Report Newington Building 1_5-11_Final.doc

Table 3 - Summary of Positive XRF Measurements above VISN1-Specified Threshold of >0.1 mg/cm2 Newington VA Medical Center, Building 1

Reading No. Floor Location Substrate and

Component Side Condition Color Results (mg/cm2)

486 SECOND 1N-217

PLASTER

WINDOW SILL East - B INTACT BLUE 4 500 SECOND 1N-207 METAL CABINET East - B INTACT TAN 0.8

531 FIRST 1S-180

METAL

CONDUIT East - B INTACT

YELLO

W 0.5

547 FIRST 1s-174

PLASTER

COLUMN North - A

Not Intact-

POOR WHITE 0.28

551 FIRST C1-3 METAL PIPE South - C Not Intact-

POOR WHITE 3.8

553 FIRST C1-3 PLASTER WALL North - A Not Intact-

POOR WHITE 1

556 FIRST 1S-167A METAL PIPE North - A INTACT

ORANG

E 0.9

557 FIRST 1S-167A

PLASTER

WINDOW SILL North - A INTACT WHITE 0.4

560 FIRST 1S-167A

PLASTER

WINDOW SILL North - A INTACT WHITE 0.4

565 FIRST 1S-167

PLASTER

COLUMN South - C INTACT WHITE 1.2

566 FIRST 1S-167

PLASTER

COLUMN South - C

Not Intact-

POOR

YELLO

W 0.29

568 FIRST

NUCLEAR

MEDICINE

METAL

FIREHOSE

CLOSET West - D INTACT WHITE 0.5

572 FIRST

NUCLEAR

MEDICINE

PLASTER

CEILING West - D INTACT BEIGE 0.11

588 FIRST Stair 3

METAL DOOR

CASING East - B INTACT BLUE 0.22 593 FIRST Stair 3 METAL STAIR

RISER

East - B INTACT BLUE 1

595 FIRST Stair 3 METAL STAIR

NEWEL POST

East - B INTACT BLUE 0.8

596 FIRST Stair 3 METAL STAIR

BALUSTER

North - A INTACT BLUE 0.3

597 FIRST Stair 3 METAL STAIR

STRINGER

North - A INTACT BLUE 1

598 FIRST Stair 3 METAL

BASEBOARD

South - C INTACT BLUE 0.8

599 FIRST Stair 3 METAL STAIR

HANDRAIL

North - A INTACT BLUE 0.6

600 FIRST Stair 3 METAL FIRE

SPRINKLER

PIPE

North - A INTACT BLACK 0.3

601 FIRST Stair 3 PLASTER

CEILING

North - A INTACT WHITE 0.7

602 FIRST Stair 3 PLASTER

CEILING

North - A INTACT WHITE 60.7

604 SECOND IN-217

VINYL FLOOR

(X-RAY) North - A INTACT WHITE 21.2 608 SECOND 1n-207 VINYL FLOOR South - C INTACT BLUE 36

©2011, Mabbett & Associates, Inc. Page 14 of 18 Survey Report Newington Building 1_5-11_Final.doc

Table 3 - Summary of Positive XRF Measurements above VISN1-Specified Threshold of >0.1 mg/cm2 Newington VA Medical Center, Building 1

Reading No. Floor Location Substrate and

Component Side Condition Color Results (mg/cm2)

613 SECOND 1n-201

VINYL FLOOR

(X-RAY) West - D INTACT BROWN 42.2

614 SECOND 1n-201

METAL SHIELD

(X-RAY) East - B INTACT WHITE 1.8

616 SECOND 1n-201

PLASTER WALL

(X-RAY) West - D INTACT WHITE 4.6

617 SECOND 1n-201

PLASTER WALL

(X-RAY) East - B INTACT WHITE 7.4 622 SECOND 1n-206 METAL PIPE North - A INTACT RED 0.5

626 SECOND 1n-213

PLASTER WALL

(X-RAY) South - C INTACT WHITE 3.1

627 SECOND 1n-218

VINYL FLOOR

(X-RAY) South - C INTACT BEIGE 18

628 SECOND 1n-218

METAL SHIELD

(X-RAY) North - A INTACT BEIGE 56.3

629 SECOND 1n-218

DRYWALL WALL

(X-RAY) South - C INTACT BLUE 5.5

631 SECOND C2-5

DRYWALL WALL

(X-RAY) North - A INTACT WHITE 0.4

635 FIRST 1S-174 METAL PIPE South - C INTACT

ORANG

E 2.3

638 FIRST 1S-171A METAL PIPE West - D Not Intact-

POOR

ORANG

E 3.2

639 FIRST 1S-171 METAL PIPE West - D Not Intact-

POOR

ORANG

E 1.3

644 FIRST STAIR #4

METAL STAIR

STRINGER South - C INTACT BLUE 0.3

645 FIRST STAIR #4

METAL STAIR

BALUSTER South - C INTACT BLUE 0.4

646 FIRST STAIR #4

METAL STAIR

RISER East - B INTACT BLUE 1.2

647 FIRST STAIR #4

METAL

BASEBOARD North - A INTACT BLUE 0.9

648 FIRST STAIR #4

METAL STAIR

HANDRAIL North - A INTACT BLUE 0.9

649 FIRST STAIR #4

METAL STAIR

NEWEL POST East - B INTACT BLUE 1.4

652 FIRST STAIR #4

PLASTER

CEILING North - A INTACT TAN 0.11

657 FIRST 1N-110 PLASTER WALL North - A INTACT WHITE 0.27 661 FIRST 1N-113 PLASTER WALL East - B INTACT WHITE 1

664 FIRST 1N-113

METAL DOOR

CASING West - D INTACT GRAY 0.3

688 FIRST 1N-109A

PLASTER

WINDOW

CASING West - D

Not Intact-

POOR BEIGE 0.3

689 FIRST 1N-109A

METAL

RADIATOR West - D Not Intact-

POOR BEIGE 0.6

705 FIRST 1N-104

METAL

PRIVACY

PARTITION East - B INTACT TAN 0.16

©2011, Mabbett & Associates, Inc. Page 15 of 18 Survey Report Newington Building 1_5-11_Final.doc

Table 3 - Summary of Positive XRF Measurements above VISN1-Specified Threshold of >0.1 mg/cm2 Newington VA Medical Center, Building 1

Reading No. Floor Location Substrate and

Component Side Condition Color Results (mg/cm2)

708 FIRST AUDIO WAITING

METAL AIR

VENT East - B INTACT TAN 0.17

711 FIRST AUDIO WAITING

PLASTER

WINDOW SILL West - D INTACT WHITE 0.13

726 FIRST WEST HALL

METAL

FIREHOSE

CLOSET South - C INTACT WHITE 0.5

727 FIRST C1-4

METAL

FIREHOSE

CLOSET West - D INTACT WHITE 0.18

EXTERI

OR EXTERIOR

METAL LINTEL

(EXTERIOR) West - D INTACT WHITE 29.9

EXTERI

OR EXTERIOR

METAL

WINDOW

LINTEL

(EXTERIOR) South - C Not Intact-

POOR WHITE 26.3

EXTERI

OR EXTERIOR

METAL FIRE

ALARM South - C INTACT RED 0.5

EXTERI

OR EXTERIOR

METAL STAIR

HANDRAIL

(EXTERIOR) East - B Not Intact-

POOR BLACK 1.6

EXTERI

OR EXTERIOR

METAL LINTEL

(EXTERIOR) East - B Not Intact-

POOR WHITE 35

EXTERI

OR EXTERIOR

METAL DOWN

SPOUT

(EXTERIOR) East - B INTACT BROWN 11.1

EXTERI

OR EXTERIOR

METAL LINTEL

(EXTERIOR) East - B Not Intact-

POOR WHITE 31.6

EXTERI

OR EXTERIOR

METAL LINTEL

(EXTERIOR) North - A Not Intact-

POOR WHITE 28.9

854 FIRST 1S-175 WOOD DOOR West - D INTACT WHITE 46.1 856 FIRST 1S-175A DRYWALL WALL South - C INTACT WHITE 8.1 857 FIRST 1S-175A DRYWALL WALL North - A INTACT WHITE 7.9

871 FIRST 1S-170

PLASTER

WINDOW SILL North - A INTACT WHITE 0.18

2271 FOURTH 1-446

CONCRETE

WALL South - C INTACT WHITE 1.4

2272 FOURTH 1-446

CONCRETE

LEDGE South - C INTACT WHITE 1.4

2298 FOURTH 1-427

METAL

WINDOW

FRAME West - D INTACT WHITE 0.5

2523 FOURTH STAIRWELL

METAL STAIR

NEWEL POST South - C

Not Intact-

POOR BLUE 0.6

2524 FOURTH STAIRWELL

METAL STAIR

HANDRAIL South - C Not Intact-

POOR BLUE 1.1

2525 FOURTH STAIRWELL

METAL STAIR

BALUSTER South - C INTACT BLUE 0.3

2526 FOURTH STAIRWELL

METAL STAIR

RISER South - C INTACT RED 1.5

©2011, Mabbett & Associates, Inc. Page 16 of 18 Survey Report Newington Building 1_5-11_Final.doc

Table 3 - Summary of Positive XRF Measurements above VISN1-Specified Threshold of >0.1 mg/cm2 Newington VA Medical Center, Building 1

Reading No. Floor Location Substrate and

Component Side Condition Color Results (mg/cm2)

2527 FOURTH STAIRWELL

METAL STAIR

STRINGER South - C INTACT BLUE 1.1

2528 FOURTH STAIRWELL

METAL

BASEBOARD South - C Not Intact-

POOR BLUE 5

2530 FOURTH STAIRWELL PLASTER WALL South - C INTACT WHITE 0.15

2531 FOURTH STAIRWELL

METAL DOOR

CASING South - C INTACT GRAY 0.2

2535 FOURTH STAIRWELL

METAL

WINDOW

FRAME West - D INTACT BLUE 6.9

2537 FOURTH STAIRWELL

METAL STAIR

RISER East - B INTACT BLUE 0.9

2538 FOURTH STAIRWELL

METAL STAIR

BALUSTER East - B INTACT BLUE 1.9

2539 FOURTH STAIRWELL

METAL STAIR

NEWEL POST East - B INTACT WHITE 0.5

2540 FOURTH STAIRWELL

METAL STAIR

HANDRAIL East - B INTACT BLUE 0.8

2541 FOURTH STAIRWELL

METAL STAIR

STRINGER East - B INTACT BLUE 1.7 2544 FOURTH STAIRWELL PLASTER WALL South - C INTACT WHITE 1.4

2548 FOURTH STAIRWELL

METAL DOOR

CASING South - C INTACT GRAY 0.24

2550 FOURTH STAIRWELL

METAL

BASEBOARD East - B INTACT BLUE 1.1 2556 FOURTH C4-7 PLASTER WALL West - D INTACT WHITE 1.4 2559 FOURTH C4-7 METAL PANEL East - B INTACT WHITE 1.2 2562 FOURTH 1-400 CERAMIC WALL East - B INTACT WHITE 0.3 2564 FOURTH 1-400 CERAMIC WALL South - C INTACT WHITE 0.3

2565 FOURTH 1-400

CONCRETE

FLOOR South - C Not Intact-

POOR GRAY 1.9

2566 FOURTH 1-400

METAL DOOR

CASING South - C INTACT WHITE 0.4 2567 FOURTH 1-400 CERAMIC WALL West - D INTACT WHITE 1.2 2568 FOURTH 1-400 METAL PIPE West - D INTACT WHITE 0.4 2571 FOURTH 1-400 METAL I-BEAM South - C INTACT WHITE 0.6

2577 FOURTH 1-400

CONCRETE

LEDGE North - A INTACT WHITE 0.12

2578 FOURTH C 4-1

METAL DOOR

CASING West - D INTACT GRAY 0.23

2592 FOURTH C 4-07

METAL FIRE

SPRINKLER

PIPE North - A INTACT RED 0.4

In addition, XRF measurements collected during the screening survey of interior and exterior building components are included in Table 5 – Summary of XRF Measurements. Table 5 includes a description of each screened surface and resulting XRF-measured lead concentration.

©2011, Mabbett & Associates, Inc. Page 17 of 18 Survey Report Newington Building 1_5-11_Final.doc

4.2.2 Photographs

Representative photographs of building materials greater than or equal to 1.0 mg/cm2 and where in other in intact condition (e.g. fair, peeling, cracking) are provided in Appendix D of this report.

4.2.3 CADD Drawings

Based on the results of the lead screening survey a table of LCP components identified with > 0.1 mg/cm2 was developed. This table is available on the CADD drawings for use by the VAMC for exposure assessments and preliminary renovation planning. Based on the results of the survey these components identified in the CADD table and on the plan should be assumed to be LCP unless otherwise determined.

5.0 LIMITATIONS

This survey report is the result of a diligent search of the building for ACM and LCP. Only accessible areas were included in this survey. Although a comprehensive inspection was performed, M&A does not claim to have identified all of the ACM and LCP that could be present in the facility (for example, materials potentially located within aforementioned inaccessible areas discussed in Section 3.1). M&A’s survey was performed with limitations inherent to visual inspections. M&A has conducted this assessment with reasonable care and has performed this project within generally accepted industry standards. There can be no assurances, and M&A makes no assurances, that the information, research, and technology used to prepare this report may not change in the future, thus affecting the results reported herein.

6.0 CLOSING REMARKS

Prior to initiating plans for maintenance, renovation or demolition activities, the VAMC should review the asbestos and lead survey results to determine whether any of the materials identified as ACM or LCP will be disturbed by proposed work activities.

6.1 Asbestos

The purpose of the ACM survey was to identify ACM in the building within the limitations of the survey for worker protection purposes and future renovation or demolition planning purposes. In regards to asbestos, any suspect material encountered during renovation/demolition that is not identified in this report as being non-ACM should be assumed to be ACM unless sample results prove otherwise. Suspect ACM that may be present within the walls, above inaccessible hard ceilings, or in other inaccessible locations, that was not inspected should be assumed to contain asbestos if discovered during any renovation process or until otherwise verified. If ACM must be disturbed, the ACM must be removed by a licensed asbestos abatement contractor and be performed in accordance with applicable regulations. If proposed work activities will not disturb ACM, continuous monitoring of ACM should be conducted throughout work activities to ensure the ACM remains in an intact condition. Additionally, prior to commencing work activities, contractors involved with the work activities should be made aware of the location of ACM, within the building in which they will be working. Additional information regarding asbestos management and the Operations & Maintenance (O&M) program is outlined in the VAMC campus wide Asbestos

©2011, Mabbett & Associates, Inc. Page 18 of 18 Survey Report Newington Building 1_5-11_Final.doc

Management Plan available in Volume I of the Comprehensive VAMC Lead and Asbestos Survey Report.

6.2 Lead Containing Paint

The purpose of the LCP screening survey was to identify patterns of LCP. For the purpose of this LCP screening survey, representative interior and exterior building components were tested. The regulations addressing LCP in non-residential building are focused on protecting workers who are involved with paint disturbing activities and related waste disposal activities.

Worker protection is regulated by OSHA regulations as well as applicable state regulations. These regulations involve air monitoring of workers to determine exposure levels when disturbing paint containing measurable lead. A lead based paint determination can not determine a safe level of lead, but is intended to provide guidance as to the locations of what are considered industry standards for lead in paint. VA employees and contractors may use this information to better determine exposures of workers to airborne lead by understanding the different concentrations of lead paint on representative components and surfaces. Worker exposure controls can then be implemented and air monitoring can then be performed during activities that disturb paint on representative surfaces.

A concentration of lead greater than or equal to 1.0 mg/cm2 exceeds HUD residential standards and is an indicator of risk. OSHA does not specify a safe concentration of LCP. However, for the purposes of this LCP screening survey the lead concentrations greater than 0.1 mg/cm2 have been utilized as a threshold established by VISN 1 for areas where possible worker exposures may occur.

Figures

Appendix A

Table 4 Summary of ACM Building Results

Newington VAMC – Building 1 May 2011 ©2011, Mabbett & Associates, Inc. Table 4 – Page 1 of 35 Survey Report Newington Building 1_5-11_Final.doc

Table 4 - Summary of ACM Building Results Newington VA Medical Center, Building 1

Sample No.

Sample Location

Description of Material

Percent and Type of Asbestos

Estimated Quantity

Condition ACM Location

VISN 1

RISK

Hazard Category

1-4* 1A 1-409 2'x2' Dot/Slash

Pattern Ceiling Tile

NAD - - - -

1B 5th Fl Corridor C5-11

2'x2' Dot/Slash Pattern Ceiling

Tile

NAD - - - -

1C 5th Fl Corridor C5-11

2'x2' Dot/Slash Pattern Ceiling

Tile

NAD - - - -

2A Kitchenette 1-C5-10

2'x2' Swirl texture Pattern

Ceiling Tile

NAD - - - -

2B 1-539 2'x2' Swirl texture Pattern

Ceiling Tile

NAD - - - -

2C 5th Fl Corridor C5-11

2'x2' Swirl texture Pattern

Ceiling Tile

NAD - - - -

3A 4th Fl Corridor C4-

Wall Board Ceiling

NAD - - - -

3B 4th Fl Corridor C4-

Wall Board Ceiling

NAD - - - -

3C 1-532 Wall Board Ceiling

NAD - - - -

4A 4th Fl Lobby C4-7

Wall Board Joint compound on ceiling

NAD - - - -

4B 1-445 Wall Board Joint compound on ceiling

NAD - - - -

4C 1-532 Wall Board Joint compound on ceiling

NAD - - - -

05A 1-445 2'x4' DAT Slash Ceiling Tile

NAD - - - -

5B 4th Fl Corridor C4-12

2'x4' DAT Slash Ceiling Tile

NAD - - - -

5C 1-516 2'x4' DAT Slash Ceiling Tile

NAD - - - -

6A 1-522 Glue For Blue Carpet

NAD - - - -

6B 1-501 Glue For Blue Carpet

NAD - - - -

6C 1-502 Glue For Blue Carpet

NAD - - - -

©2011, Mabbett & Associates, Inc. Table 4 – Page 2 of 35 Survey Report Newington Building 1_5-11_Final.doc

Table 4 - Summary of ACM Building Results Newington VA Medical Center, Building 1

Sample No.

Sample Location

Description of Material

Percent and Type of Asbestos

Estimated Quantity

Condition ACM Location

VISN 1

RISK

Hazard Category

1-4* 7A 1-509 Glue For

Multicolor Purple/Blue

Carpet

NAD - - - -

7B 5th Fl Waiting Room 1-C-52

Glue For Multicolor

Purple/Blue Carpet

NAD - - - -

7C 5th Fl Corridor C5-11

Glue For Multicolor

Purple/Blue Carpet

NAD - - - -

8A 5th Fl Corridor C5-11

Glue For 4" Gray Vinyl Base

(NEW)

NAD - - - -

8B 1-517 Glue For 4" Gray Vinyl Base

(New)

NAD - - - -

8C 5th Fl Corridor C5-11

Glue For 4" Gray Vinyl Base

(New)

NAD - - - -

9A 1-501 Glue For 4" Dark Blue Vinyl Base

NAD - - - -

9B 1-517 Glue For 4" Dark Blue Vinyl Base

NAD - - - -

9C 1-512 Glue For 4" Dark Blue Vinyl Base

NAD - - - -

10A 1-417 Glue For 4" Dark Blue Vinyl Base

NAD - - - -

10B 1-409 Wall Board Walls NAD - - - - 10C 1-429 Wall Board Walls NAD - - - - 11A 1-417 Wall Board Joint compound on Walls Only

NAD - - - -

11B 1-426 Wall Board Joint compound on

Walls Only

NAD - - - -

11C 1-409 Wall Board Joint compound on

Walls Only

NAD - - - -

11D 1-429 Wall Board Joint compound on

Walls Only

NAD - - - -

11E 1-429 Wall Board Joint compound on

Walls Only

©2011, Mabbett & Associates, Inc. Table 4 – Page 3 of 35 Survey Report Newington Building 1_5-11_Final.doc

Table 4 - Summary of ACM Building Results Newington VA Medical Center, Building 1

Sample No.

Sample Location

Description of Material

Percent and Type of Asbestos

Estimated Quantity

Condition ACM Location

VISN 1

RISK

Hazard Category

1-4* 11F 4th Fl

Corridor C4-12

Wall Board Joint compound on

Walls Only

NAD - - - -

11G 1-419 Wall Board Joint compound on

Walls Only

NAD - - - -

12A 5th Fl Open Office C5-5

Gray fire proofing insulation

NAD - - - -

12B 1-521 Gray fire proofing insulation

NAD - - - -

12C 5th Fl Open Office C5-5

Gray fire proofing insulation

NAD - - - -

13A 5th Fl Corridor

C5-7

12" Gray w/Black specs vinyl floor tile

NAD - - - -

13B 5th Fl Corridor

C5-7

12" Gray w/Black specs vinyl floor tile

NAD - - - -

13C 5th Fl Elevator Lobby C5-4

12" Gray w/Black specs vinyl floor tile

NAD - - - -

14A 5th Fl Corridor

C5-7

12" Pink vinyl floor tile

NAD - - - -

14B 5th Fl Corridor

C5-7

12" Pink vinyl floor tile

NAD - - - -

14C 5th Fl Elevator Lobby C5-4

12" Pink vinyl floor tile

NAD - - - -

15A 5th Fl Corridor

C5-7

Flooring mastic under 12" Gray +12" pink floor tile

NAD - - - -

15B 5th Fl Corridor

C5-7

Flooring mastic under 12" Gray +12" pink floor tile

NAD - - - -

15C 5th Fl Elevator Lobby C5-4

Flooring mastic under 12" Gray +12" pink floor tile

NAD - - - -

16A 1-316 Sink under coating black

©2011, Mabbett & Associates, Inc. Table 4 – Page 4 of 35 Survey Report Newington Building 1_5-11_Final.doc

Table 4 - Summary of ACM Building Results Newington VA Medical Center, Building 1

Sample No.

Sample Location

Description of Material

Percent and Type of Asbestos

Estimated Quantity

Condition ACM Location

VISN 1

RISK

Hazard Category

1-4* 16B 1-316 Sink under coating black

NAD - - - -

16C 1-316 Sink under coating black

NAD - - - -

17A 1-445 White interior window sill caulk

NAD - - - -

17B 1-522 White interior window sill caulk

NAD - - - -

17C 1-322 White interior window sill caulk

NAD - - - -

18A Exterior Gray Exterior Window Sill

Caulk

15% Chrysotile

800 LF Good Exterior 4

18B Exterior Gray Exterior window sill caulk

NAD - - - -

18C Exterior Gray Exterior window sill caulk

NAD - - - -

19A 1-536 Glue for

Glue/Tan swirled carpet

19B 5th Fl Waiting Room 1-C5-8

Glue for

19C 5th Fl Corridor C5-

Glue for

20A 4th Fl Stairway #1

Glue for 6" Black vinyl base on stair

NAD - - - -

20B 4th Fl Stairway #1

Glue 6" Black vinyl base on stair

NAD - - - -

20C 4th Fl Stairway #1

Glue 6" Black vinyl base on stair

NAD - - - -

21A 4th Fl Stairway #3

Glue for Red Rubber Stair

Treads

<1% Chrysotile

21B 4th Fl Stairway #3

Glue for Red Rubber Stair

Treads

Chrysotile

500 SF

Good

Stair #1, Stair #3

©2011, Mabbett & Associates, Inc. Table 4 – Page 5 of 35 Survey Report Newington Building 1_5-11_Final.doc

Table 4 - Summary of ACM Building Results Newington VA Medical Center, Building 1

Sample No.

Sample Location

Description of Material

Percent and Type of Asbestos

Estimated Quantity

Condition ACM Location

VISN 1

RISK

Hazard Category

1-4* 21C 2nd Fl

Stairway #1 Glue for Red Rubber Stair

Treads

2% Chrysotile

22A 4th Fl Stairway #3

12” Beige w/Black Streaks Vinyl Floor Tile

1% Chrysotile

22B 4th Fl Stairway #3

12” Beige w/Black Streaks Vinyl Floor Tile

2% Chrysotile

22C 5th Floor Stairwell #3

12” Beige w/Black Streaks Vinyl Floor Tile

3% Chrysotile

200 SF Good 4th Fl Stairway #3, 5th Fl Stairwell #3

23A 4th Fl Stairway #3

Mastic for 12” Beige w/Black Streaks Vinyl

Tile

2% Chrysotile

23B 4th Fl Stairway #3

Mastic for 12” Beige w/Black Streaks Vinyl

Tile

2% Chrysotile

23C 5th Floor Stairway #3

Mastic for 12” Beige w/Black Streaks Vinyl

Tile

5% Chrysotile

200 SF Good 4th Fl Stairway #3, 5th Fl Stairwell #3

24A 4th Fl Stairway #1

12" white w/blacks specks vinyl floor tile

NAD - - - -

24B 4th Fl Corridor C4-12

12" white w/blacks specks vinyl floor tile

NAD - - - -

24C 1-534 12" white w/blacks specks vinyl floor tile

NAD - - - -

25A 4th Fl Stairway #1

Mastic for 12" white w/ black specks vinyl floor tile

NAD - - - -

25B 4th Fl Corridor C4-12

Mastic for 12" white w/ black specks vinyl floor tile

NAD - - - -

25C 1-534 Mastic for 12" white w/ black specks vinyl floor tile

NAD - - - -

26A 1-532A Gray steel sink undercoating

©2011, Mabbett & Associates, Inc. Table 4 – Page 6 of 35 Survey Report Newington Building 1_5-11_Final.doc

Table 4 - Summary of ACM Building Results Newington VA Medical Center, Building 1

Sample No.

Sample Location

Description of Material

Percent and Type of Asbestos

Estimated Quantity

Condition ACM Location

VISN 1

RISK

Hazard Category

1-4* 26B 1-532A Gray steel sink undercoating

NAD - - - -

26C 1-532A Gray steel sink undercoating

NAD - - - -

27A 1-537 Glue for blue leaf pattern carpet

NAD - - - -

27B 1-528 Glue for blue leaf pattern carpet

NAD - - - -

27C 5th Fl Corridor C5-12

Glue for blue leaf pattern carpet

NAD - - - -

28A 1-400 Wall plaster-white skim coat

NAD - - - -

28B 1-446

Wall plaster-white skim coat

NAD - - - -

28C 1-322 Wall plaster-white skim coat

NAD - - - -

28D 3rd Fl Corridor C3-

Wall plaster-white skim coat

NAD - - - -

28E 2nd Fl Lobby C2-1

Wall plaster-white skim coat

NAD - - - -

28F 2nd Fl Corridor C2-

Wall plaster-white skim coat

NAD - - - -

28G 2nd Fl Corridor C2-

Wall plaster-white skim coat

NAD - - - -

29A 1-400 Wall plaster- Base coat

NAD - - - -

29B 1-446 Wall plaster- Base coat

NAD - - - -

29C 1-322 Wall plaster- Base coat

NAD - - - -

29D 3rd Fl Corridor C3-

Wall plaster- Base coat

NAD - - - -

29E 2nd Fl Lobby C2-1

Wall plaster- Base coat

NAD - - - -

29F 2nd Fl Corridor C2-

Wall plaster- Base coat

NAD - - - -

29G 2nd Fl Corridor C2-

Wall plaster- Base coat

©2011, Mabbett & Associates, Inc. Table 4 – Page 7 of 35 Survey Report Newington Building 1_5-11_Final.doc

Table 4 - Summary of ACM Building Results Newington VA Medical Center, Building 1

Sample No.

Sample Location

Description of Material

Percent and Type of Asbestos

Estimated Quantity

Condition ACM Location

VISN 1

RISK

Hazard Category

1-4* 30A 4th Fl Stair 1 12" white w/ black + red streaks vinyl floor tile

NAD - - - -

30B 4th Fl Stair 1 12" white w/black + red streaks vinyl floor tile

NAD - - - -

30C 4th Fl Stair 1 12" white w/ black + red streaks vinyl floor tile

NAD - - - -

31A 4th Fl Stair 1 Mastic for 12" white w/black + red streaks vinyl floor tile

NAD - - - -

31B 4th Fl Stair 1 Mastic for 12" white w/black + red streaks vinyl floor tile

NAD - - - -

31C 4th Fl Stair 1 Mastic for 12" white w/black + red streaks vinyl floor tile

NAD - - - -

32A 1-443 Ceiling plaster-skim coat

NAD - - - -

32B 1-400 Ceiling plaster-skim coat

NAD - - - -

32C 1-322 Ceiling plaster-skim coat

NAD - - - -

32D 1-322 Ceiling plaster-skim coat

NAD - - - -

32E 1-322 Ceiling plaster-skim coat

NAD - - - -

32F IN-110 Ceiling plaster-skim coat

NAD - - - -

32G 1st Fl Corridor C1-

Ceiling plaster-skim coat

NAD - - - -

33A 1-443 Ceiling plaster- Base coat

NAD - - - -

33B 1-400 Ceiling plaster- Base coat

NAD - - - -

33C 1-322 Ceiling plaster- Base coat

NAD - - - -

33D 1-322 Ceiling plaster- Base coat

NAD - - - -

33E 1-322 Ceiling…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .