36C10F19R0086-0007001.pdf
PDF Posted
- Attached to
- Replace Boiler Plant and Steam Distribution System Federal contract opportunity
- Solicitation number
- 36C10F19R0086
About this file
This sources sought notice is seeking capability statements from small business contractors for a design-bid-build contract to replace an existing 8,000 square foot boiler plant and construct a 2,087 square foot addition at the Department of Veterans Affairs Alexandria VA Health Care System in Pineville, Louisiana. Firms must have an approved NAICS code of 236220 for general construction with a small business size standard of $39.5 million in average annual receipts. Responses were due by October 3, 2019 and should have included company information, certification of small business status, available bonding capacity, and a capability statement not exceeding five pages exhibiting relevant construction experience on similar sized and complex projects. The estimated contract value is between $10-20 million.
36C10F19R0086 0007 Amendment 7.pdf
View the file
Other files for this federal contract opportunity
Show all 50
Replace Boiler Plant and Steam Distribution System has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Harrell Design Group, PC
AMENDMENT #7
April 21, 2020
REPLACE BOILER PLANT & STEAM DISTRIBUTION SYSTEM
ALEXANDRIA VA HEALTH CARE SYSTEM PINEVILLE, LA
VA Project Number 502-14-102V
I. BIDDER COMMENTS / RESPONSES (Refer to separately attached Bidder Question /
Response Sheets).
II. SPECIFICATIONS (no changes).
III. DRAWINGS (Refer to attached drawings for clouded changes).
1. The following drawings are revised and reissued:
A. AE601:
a. Except for deletion of coiling doors and grilles 1A100.2, 1A100.3, and 1A100.4, door schedule is revised to revert to previous Amendment 2 issuance, dated 02/03/2020.
END OF AMENDMENT #7
DOOR SIZES
MARK WIDTH HEIGHT
A 1' - 6" 6' - 8"
B 2' - 0" 6' - 8"
C 2' - 2" 6' - 8"
D 2' - 4" 6' - 8"
E 2' - 6" 6' - 8"
F 2' - 8" 6' - 8"
G 2' - 10" 6' - 8"
H 3' - 0" 6' - 8"
I 3' - 2" 6' - 8"
J 3' - 4" 6' - 8"
K 3' - 8" 6' - 8"
L 3' - 10" 6' - 8"
M 3' - 8 1/2" 7' 11 3/4"
N 2' - 0"
O 2' - 2"
P 2' - 4"
Q 2' - 6"
R 2' - 8"
S
T
3' - 0"
U
V
3' - 4"
W
3' - 8"
X
3' - 10"
Y 3' - 0" 8' - 0"
MARK WIDTH HEIGHT
Z
7' - 0"
7' - 0"
7' - 0"
7' - 0"
7' - 0"
7' - 0"
7' - 0"
7' - 0"
7' - 0"
7' - 0"
7' - 0"
3' - 6"
4' - 0"
1' - 6" 10' - 10"
0' - 9"
1'
0"
3'
6"
0' - 9"
0' - 9"
3'
6"
0'
9"
0' - 9"
12" MAX
0' - 9"
1'
6"0'
7"
0' - 9" MIN 0' - 9" MIN
0'
9" 1'
0"
0'
9"
0' - 9" 0' - 9"
2'
0" 4'
3"
MUNTINS AS
REQ'D
T.A. OR W/F
LOUVER SIZE AS
REQ'D
100 SQ IN MAX
4"x25"
T.A. OR W/F
M
'A' LABEL
180 MINUTE
'B' LABEL
90 MINUTE
100 IN2 MAX
4"x25"
'F' GLASS
SHELF
'B' LABEL
90 MINUTE
'C' LABEL
45 MINUTE
DUTCH DOOR
15/1
7LEAD LINED
8"x10" LEAD
GLASS IF
REQ'D (DR 15)
RAY PROOF
L IF REQ'D
(DR 15)
SOUND RATED
DETENTION TYPE
LOUVERS
AS REQ'D
SECURITY VAULT
DOOR
SECURITY DOOR
SECURITY
RM DR
INEGRATED
DOOR
ASSEMBLY
40 42
INEGRATED
DOOR
ASSEMBLY
1296 SQ IN MAX
EACH LEAF 4"x25"
'F' GLASS
COMBINATION
LOCK & HANDLE
T.A. VIEWER
DOOR MODIFICATIONS (APPLICATION CODES)
A LAMINATED GLAZING
D DOUBLE GLAZED TEMPERED GLASS
H ELECTRIC HOLD
L LOUVER
LP LIGHT PROOF LOUVER
M MECHANICAL SEAL FOR LIGHT PROOF AND
SOUND RETARDING DOOR
T TEMPERED GLASS
U UNDERCUT 1"
V LEAD GLASS
W WIRE GLASS
SD SLIDING DOOR (SEE PLAN FOR CLEAR OPENING)
DOOR NOTES:
1. ALL DOORS SHALL BE FLUSH - 1 3/4" THICK
UNLESS NOTED OTHERWISE
2. TOP AND SIDE RAILS SHALL BE 9" MIN.
BOTTOM RAILS SHALL BE 12" MIN.
3. DOOR TYPES 7,8, & 9 SHALL NOT BE USED
FOR OPPOSING DOORS.
4. EVEN NUMBERS ARE METAL; ODD NUMBER
ARE SOLID CORE WOOD.
5. NOT ALL DOOR TYPES ARE USED.
GLASS OR
LOUVER
REQUIRED BY
MODIFICATION
GLASS OR
LOUVER
REQUIRED BY
ELEVATION TYPE
5'
0"
5'
0"
GENERAL NOTES
A. CONTRACTOR IS RESPONSIBLE FOR
COORDINATING DOORS, DOOR
FRAMES, AND HARDWARE.
B. HARDWARE SUPPLIER IS RESPONSIBLE
FOR BUILDING CODE AND FIRE RATED
DOOR REQUIREMENTS.
C. ALL FIRE RATED DOORS SHALL HAVE
APPLIED U.L. LABEL ON HINGE SIDE. IF
DOOR IS RATED, THEN FRAME ALSO
REQUIRES MATCHING UL LABEL.
D. FRAME SIZES TO BE COORDINATED
WITH PARTITION WIDTHS ON THE JOB
SITE BY CONTRACTOR.
E. PROVIDE TWO (2) 16 GAUGE METAL
STUDS AT ALL DOOR JAMBS AND
PARTITION CORNERS.
F. GLASS SHALL BE PERMANENTLY
MARKED TO INDICATE THAT IT IS
TEMPERED.
G. AFTER INSTALLATION OF EACH
HOLLOW METAL DOOR FRAME, MARK
THE ROOM NUMBER ON THE INTERIOR
AND EXTERIOR OF THE FRAME WITH
INK THAT WILL NOT BE VISIBLE AFTER
THE SPECIFIED FINISHING IS
COMPLETED.
H. WOOD VENEER AND FINISH TO MATCH
FACILITY STANDARDS.
AS SCH
AS
S
C H
AD
J U
ST
C M
U T
O C
O U
R S E
2"
2" 2" AS SCH
AS
S
C H
2"
2" 2"
1 2
AS SCH2" 2"
AS
S
C H
AS SCH
AS
S
C H
AD
J U
ST
C M
U T
O C
O U
R S E
2"
2" 2"
8"
1' - 0"
T
AS SCH
AS
S
C H
CW
AL
WIDE STILE ALUMINUM
ENTRANCE
HOLLOW
METAL
HOLLOW
METAL
POCKET DOOR
HOLLOW
METAL w/ SIDE
LITE
2-SIDED
HOLLOW
METAL
ALUMINUM
CURTAIN WALL
REF: GI011 FOR
CURTAIN WALL
TYPES
NEW CONTROL
143' - 7 1/2"
2"2' - 8"2"
3' - 0"
IG #1
2" 3'
8"
2" 3'
0"
4'
0"
1 2 A
T, 90 MIN.
DOOR SYMBOL
FRAME TYPE
(JAMB DETAIL) DOOR TYPE
DOOR RATING
DOOR SIZE DOOR MODIFICATION
DOOR RATINGS
UL LABEL RATING (HRS) RATING (MIN.) MAX. GLASS AREA
A 3 HR 180 MIN. 100 SQUARE INCHES PER LEAF
B 1 1/2 HR 90 MIN. 100 SQUARE INCHES PER LEAF
C 3/4 HR 45 MIN. 1296 SQUARE INCHES PER LEAF
D 1 1/2 HR 90 MIN. REFER TO LOCAL CODES
E 3/4 HR 45 MIN. REFER TO LOCAL CODES
1/3 HR 20 MIN. 1296 SQUARE INCHES PER LEAF
S SMOKE SMOKE
UL LABLES D AND E ARE FOR EXTERIOR DOORS THAT ARE SUBJECT TO FIRE HAZARDS FROM
THE OUTSIDE OF THE DOOR.
LOUVER
GENERATOR
EQ EQ
8' - 0"
8'
0"
BOILER RM LEVEL
138' - 7 1/2"
± 7' - 4 7/8" V.I.F.
0" V
.I.
F.
3'
0"
V .I.
F.
T.O. GRATING
141' - 7 1/2"
D5
AE502
D3
AE503
BOILER RM LEVEL
138' - 7 1/2"
NEW CONTROL
143' - 7 1/2"±
3'
6" V
.I.
F.
4'
0"
V .I.
F.± 7' - 3" V.I.F.
02.68
2" 3'
2"
2"3' - 8"2"3' - 8 1/8"2"3' - 7 7/8"2"
11' - 8"
MG
#1
MG
#1
MG
#1
T.O. GRATING
141' - 7 1/2"
3'
6"
4'
2" 2'
6"
2'
0" 3'
0"
LINE OF EXISTING
DEMO'D WINDOW
SHOWN FOR CLARITY
3' - 4"
4'
0" 3'
0"
2" 3' - 0" 2"
2" 3'
8"
2"
FG #1
6" th re e in ch es o ne fo ot
6" th re e qu ar te rs in ch o ne fo ot
6" on e in ch o ne fo ot on e an d on e ha lf in ch es o ne fo ot on e ha lf in ch o ne fo ot
6" th re e ei gh th s in ch o ne fo ot on e ei gh th in ch o ne fo ot on e qu ar te r i nc h on e fo ot 1 2 3 4 5
Drawing Title:Seal:
FULLY SPRINKLERED
ARCHITECT / ENGINEERS:
Project Title:
Date:
Project Number:
Drawing Number:
Drawn:Checked:
Building Number:
D C
B A
Revisions:
8016 TOWER POINT DRIVE
CHARLOTTE, NC 28227
P 704.814.1320 F 704.321.0833
Project Phase:
D C
B A
1 2 3 4 5 6
Location:
CONSULTANTS:
Office of
Construction and Facilities Management
MAIN OFFICE
BIM 360://16009 Alexandria Boiler Plant/16009 - ARCH - R2018.rvt
HDG PROJECT: 16009 AE601
DOOR SCHEDULES & WINDOW
LOUVER DETAILS
BID DOCUMENTS
REPLACE BOILER PLANT &
STEAM DISTRIBUTION
SYSTEM
JUNE 14, 2019
ALEXANDRIA VA HEALTH CARE SYSTEM
PINEVILLE, LA
502-14-102V
DOOR SCHEDULE
DOOR NO SIZE
DOOR FRAME
RATING HW SIGN REMARKSTYPE MAT'L TYPE MAT'L
1A100.1 YY 2 HM 1 HM SH-9 CR
1A100.5 S 2 HM 1 HM SH-3 CR
1A100.6 S 8 HM 1 HM 90 MIN. SH-3D CR
1A100.7 S 8 HM 1 HM 90 MIN. 1R
1A101.2 S 2 HM 1 HM 5
1A103.1 S 1 WD 1 HM 5G
1A104.1 S 1 WD 1 HM 2
1A105.1 S 1 WD 1 HM 3E
1A106.1 S 7 WD 1 HM 90 MIN. 3H
1A106.2 S 7 WD 1 HM 90 MIN. 3H
1A107.1 S 1 WD 1 HM 5D CR
1A108.1 S 1 WD 1 HM 3E
1A109.1 S 4 WD 1 HM 5
1A111.1 S 8 HM 1 HM 90 MIN. 5
1A113.1 S 1 WD 1 HM 5
1A116.1 S 2 HM 1 HM 11
E3 SS 2 HM 1 HM SH-9 CR
E4 SS 2 HM 1 HM SH-9
E5 SS 2 HM 1 HM SH-9
E6 S 2 HM 1 HM SH-3 CR
1/4" = 1'-0"
C2 DOOR AND FRAME TYPES
W2
DOOR SYMBOL LEGEND
1/4" = 1'-0"
D5 LOUVERS
1/4" = 1'-0"
D3 HOLLOW METAL WINDOW ELEVATIONS
W1
02.68 INFILL EXISTING WALL OPENING WITH MASONRY -
SEE STRUCTURAL (TYP) AND ADD LAYERS OF GWB
TO FLUSH WITH ADJACENT FINISH.
- SHEET KEYNOTES
2'0 4' 8'2'0 4' 8'
MG #1 LAMINATED SAFETY GLASS, BLAST RESISTANT. BASIS OF DESIGN: KRIEGER WIN - KBR -3.0 (WITH CUSTOM FRAME)
FG #1 FIRELITE GLASS - RATED 2 HOURS
IG #1 SEE SPEC SECTION 08 52 13
GLAZING TYPE CLARIFICATION
W3
OCTOBER 18, 2019
No. Description Date
1 Amendment 2 2/03/2020 2 Amendment 6 4/09/2020 3 Amendment 7 4/21/2020
EXCEPT FOR DELETION OF COILING
DOORS AND GRILLES 1A100.2,
1A100.3, AND 1A100.4, DOOR
SCHEDULE IS REVISED TO REVERT
TO PREVIOUS AMENDMENT 2.
| AE601 Amendment 7.pdf |
| Sheets |
| AE601 - DOOR SCHEDULES & WINDOW LOUVER DETAILS |
| AE601 Amendment 7.pdf |
| Sheets |
| AE601 - DOOR SCHEDULES & WINDOW LOUVER DETAILS |
| 2020-04-21T17:13:00-0400 | |
| Jonathan M. Carr, AIA, NCARB, CDT |
File details come from the government source that posted it. Updated .