Replace Boiler Plant and Steam Distribution System Federal contract opportunity
Solicitation number
36C10F19R0086
Issued by
Department of Veterans Affairs Office of Construction and Facilities Management

About this file

This sources sought notice is seeking capability statements from small business contractors for a design-bid-build contract to replace an existing 8,000 square foot boiler plant and construct a 2,087 square foot addition at the Department of Veterans Affairs Alexandria VA Health Care System in Pineville, Louisiana. Firms must have an approved NAICS code of 236220 for general construction with a small business size standard of $39.5 million in average annual receipts. Responses were due by October 3, 2019 and should have included company information, certification of small business status, available bonding capacity, and a capability statement not exceeding five pages exhibiting relevant construction experience on similar sized and complex projects. The estimated contract value is between $10-20 million.

36C10F19R0086 0007 Amendment 7.pdf

View the file

Other files for this federal contract opportunity

Other files attached to Replace Boiler Plant and Steam Distribution System, newest first.
File Type Posted
36C10F19R0086-0007000.docx DOCX document
36C10F19R0086-0006000.docx DOCX document
36C10F19R0086-0003012.pdf PDF
36C10F19R0086-0003011.pdf PDF
36C10F19R0086-0002038.pdf PDF
36C10F19R0086-0002033.pdf PDF
36C10F19R0086-0002014.jpg JPG image
36C10F19R0086-0002046.pdf PDF
36C10F19R0086-0002017.jpg JPG image
36C10F19R0086-0002024.jpg JPG image
36C10F19R0086-0002041.pdf PDF
36C10F19R0086-0002023.jpg JPG image
36C10F19R0086-0002028.pdf PDF
36C10F19R0086-0002007.pdf PDF
36C10F19R0086-0002005.jpg JPG image
36C10F19R0086-0002001.pdf PDF
36C10F19R0086-0002042.pdf PDF
36C10F19R0086-0002018.jpg JPG image
36C10F19R0086-0002044.pdf PDF
36C10F19R0086-0002047.pdf PDF
36C10F19R0086-0002035.pdf PDF
36C10F19R0086-0002030.pdf PDF
36C10F19R0086-0002020.jpg JPG image
36C10F19R0086-0002022.jpg JPG image
36C10F19R0086-0002003.jpg JPG image
36C10F19R0086-0002032.pdf PDF
36C10F19R0086-0002019.jpg JPG image
36C10F19R0086-0002015.jpg JPG image
36C10F19R0086-0002009.jpg JPG image
36C10F19R0086-0002026.pdf PDF
36C10F19R0086-0001003.ppt PPT presentation
36C10F19R0086-0001001.pdf PDF
36C10F19R0086-008.pdf PDF
36C10F19R0086-007.pdf PDF
36C10F19R0086-029.pdf PDF
36C10F19R0086-011.pdf PDF
36C10F19R0086-012.pdf PDF
36C10F19R0086-015.pdf PDF
36C10F19R0086-013.pdf PDF
36C10F19R0086-036.pdf PDF
36C10F19R0086-034.pdf PDF
36C10F19R0086-014.pdf PDF
36C10F19R0086-032.pdf PDF
36C10F19R0086-037.pdf PDF
36C10F19R0086-033.pdf PDF
36C10F19R0086-006.pdf PDF
36C10F19R0086-005.pdf PDF
36C10F19R0086-031.pdf PDF
36C10F19R0086-027.pdf PDF
36C10F19R0086-019.pdf PDF
Show all 50

Replace Boiler Plant and Steam Distribution System has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Harrell Design Group, PC

AMENDMENT #7

April 21, 2020

REPLACE BOILER PLANT & STEAM DISTRIBUTION SYSTEM

ALEXANDRIA VA HEALTH CARE SYSTEM PINEVILLE, LA

VA Project Number 502-14-102V

I. BIDDER COMMENTS / RESPONSES (Refer to separately attached Bidder Question /

Response Sheets).

II. SPECIFICATIONS (no changes).

III. DRAWINGS (Refer to attached drawings for clouded changes).

1. The following drawings are revised and reissued:

A. AE601:

a. Except for deletion of coiling doors and grilles 1A100.2, 1A100.3, and 1A100.4, door schedule is revised to revert to previous Amendment 2 issuance, dated 02/03/2020.

END OF AMENDMENT #7

DOOR SIZES

MARK WIDTH HEIGHT

A 1' - 6" 6' - 8"

B 2' - 0" 6' - 8"

C 2' - 2" 6' - 8"

D 2' - 4" 6' - 8"

E 2' - 6" 6' - 8"

F 2' - 8" 6' - 8"

G 2' - 10" 6' - 8"

H 3' - 0" 6' - 8"

I 3' - 2" 6' - 8"

J 3' - 4" 6' - 8"

K 3' - 8" 6' - 8"

L 3' - 10" 6' - 8"

M 3' - 8 1/2" 7' 11 3/4"

N 2' - 0"

O 2' - 2"

P 2' - 4"

Q 2' - 6"

R 2' - 8"

S

T

3' - 0"

U

V

3' - 4"

W

3' - 8"

X

3' - 10"

Y 3' - 0" 8' - 0"

MARK WIDTH HEIGHT

Z

7' - 0"

7' - 0"

7' - 0"

7' - 0"

7' - 0"

7' - 0"

7' - 0"

7' - 0"

7' - 0"

7' - 0"

7' - 0"

3' - 6"

4' - 0"

1' - 6" 10' - 10"

0' - 9"

1'

0"

3'

6"

0' - 9"

0' - 9"

3'

6"

0'

9"

0' - 9"

12" MAX

0' - 9"

1'

6"0'

7"

0' - 9" MIN 0' - 9" MIN

0'

9" 1'

0"

0'

9"

0' - 9" 0' - 9"

2'

0" 4'

3"

MUNTINS AS

REQ'D

T.A. OR W/F

LOUVER SIZE AS

REQ'D

100 SQ IN MAX

4"x25"

T.A. OR W/F

M

'A' LABEL

180 MINUTE

'B' LABEL

90 MINUTE

100 IN2 MAX

4"x25"

'F' GLASS

SHELF

'B' LABEL

90 MINUTE

'C' LABEL

45 MINUTE

DUTCH DOOR

15/1

7LEAD LINED

8"x10" LEAD

GLASS IF

REQ'D (DR 15)

RAY PROOF

L IF REQ'D

(DR 15)

SOUND RATED

DETENTION TYPE

LOUVERS

AS REQ'D

SECURITY VAULT

DOOR

SECURITY DOOR

SECURITY

RM DR

INEGRATED

DOOR

ASSEMBLY

40 42

INEGRATED

DOOR

ASSEMBLY

1296 SQ IN MAX

EACH LEAF 4"x25"

'F' GLASS

COMBINATION

LOCK & HANDLE

T.A. VIEWER

DOOR MODIFICATIONS (APPLICATION CODES)

A LAMINATED GLAZING

D DOUBLE GLAZED TEMPERED GLASS

H ELECTRIC HOLD

L LOUVER

LP LIGHT PROOF LOUVER

M MECHANICAL SEAL FOR LIGHT PROOF AND

SOUND RETARDING DOOR

T TEMPERED GLASS

U UNDERCUT 1"

V LEAD GLASS

W WIRE GLASS

SD SLIDING DOOR (SEE PLAN FOR CLEAR OPENING)

DOOR NOTES:

1. ALL DOORS SHALL BE FLUSH - 1 3/4" THICK

UNLESS NOTED OTHERWISE

2. TOP AND SIDE RAILS SHALL BE 9" MIN.

BOTTOM RAILS SHALL BE 12" MIN.

3. DOOR TYPES 7,8, & 9 SHALL NOT BE USED

FOR OPPOSING DOORS.

4. EVEN NUMBERS ARE METAL; ODD NUMBER

ARE SOLID CORE WOOD.

5. NOT ALL DOOR TYPES ARE USED.

GLASS OR

LOUVER

REQUIRED BY

MODIFICATION

GLASS OR

LOUVER

REQUIRED BY

ELEVATION TYPE

5'

0"

5'

0"

GENERAL NOTES

A. CONTRACTOR IS RESPONSIBLE FOR

COORDINATING DOORS, DOOR

FRAMES, AND HARDWARE.

B. HARDWARE SUPPLIER IS RESPONSIBLE

FOR BUILDING CODE AND FIRE RATED

DOOR REQUIREMENTS.

C. ALL FIRE RATED DOORS SHALL HAVE

APPLIED U.L. LABEL ON HINGE SIDE. IF

DOOR IS RATED, THEN FRAME ALSO

REQUIRES MATCHING UL LABEL.

D. FRAME SIZES TO BE COORDINATED

WITH PARTITION WIDTHS ON THE JOB

SITE BY CONTRACTOR.

E. PROVIDE TWO (2) 16 GAUGE METAL

STUDS AT ALL DOOR JAMBS AND

PARTITION CORNERS.

F. GLASS SHALL BE PERMANENTLY

MARKED TO INDICATE THAT IT IS

TEMPERED.

G. AFTER INSTALLATION OF EACH

HOLLOW METAL DOOR FRAME, MARK

THE ROOM NUMBER ON THE INTERIOR

AND EXTERIOR OF THE FRAME WITH

INK THAT WILL NOT BE VISIBLE AFTER

THE SPECIFIED FINISHING IS

COMPLETED.

H. WOOD VENEER AND FINISH TO MATCH

FACILITY STANDARDS.

AS SCH

AS

S

C H

AD

J U

ST

C M

U T

O C

O U

R S E

2"

2" 2" AS SCH

AS

S

C H

2"

2" 2"

1 2

AS SCH2" 2"

AS

S

C H

AS SCH

AS

S

C H

AD

J U

ST

C M

U T

O C

O U

R S E

2"

2" 2"

8"

1' - 0"

T

AS SCH

AS

S

C H

CW

AL

WIDE STILE ALUMINUM

ENTRANCE

HOLLOW

METAL

HOLLOW

METAL

POCKET DOOR

HOLLOW

METAL w/ SIDE

LITE

2-SIDED

HOLLOW

METAL

ALUMINUM

CURTAIN WALL

REF: GI011 FOR

CURTAIN WALL

TYPES

NEW CONTROL

143' - 7 1/2"

2"2' - 8"2"

3' - 0"

IG #1

2" 3'

8"

2" 3'

0"

4'

0"

1 2 A

T, 90 MIN.

DOOR SYMBOL

FRAME TYPE

(JAMB DETAIL) DOOR TYPE

DOOR RATING

DOOR SIZE DOOR MODIFICATION

DOOR RATINGS

UL LABEL RATING (HRS) RATING (MIN.) MAX. GLASS AREA

A 3 HR 180 MIN. 100 SQUARE INCHES PER LEAF

B 1 1/2 HR 90 MIN. 100 SQUARE INCHES PER LEAF

C 3/4 HR 45 MIN. 1296 SQUARE INCHES PER LEAF

D 1 1/2 HR 90 MIN. REFER TO LOCAL CODES

E 3/4 HR 45 MIN. REFER TO LOCAL CODES

1/3 HR 20 MIN. 1296 SQUARE INCHES PER LEAF

S SMOKE SMOKE

UL LABLES D AND E ARE FOR EXTERIOR DOORS THAT ARE SUBJECT TO FIRE HAZARDS FROM

THE OUTSIDE OF THE DOOR.

LOUVER

GENERATOR

EQ EQ

8' - 0"

8'

0"

BOILER RM LEVEL

138' - 7 1/2"

± 7' - 4 7/8" V.I.F.

0" V

.I.

F.

3'

0"

V .I.

F.

T.O. GRATING

141' - 7 1/2"

D5

AE502

D3

AE503

BOILER RM LEVEL

138' - 7 1/2"

NEW CONTROL

143' - 7 1/2"±

3'

6" V

.I.

F.

4'

0"

V .I.

F.± 7' - 3" V.I.F.

02.68

2" 3'

2"

2"3' - 8"2"3' - 8 1/8"2"3' - 7 7/8"2"

11' - 8"

MG

#1

MG

#1

MG

#1

T.O. GRATING

141' - 7 1/2"

3'

6"

4'

2" 2'

6"

2'

0" 3'

0"

LINE OF EXISTING

DEMO'D WINDOW

SHOWN FOR CLARITY

3' - 4"

4'

0" 3'

0"

2" 3' - 0" 2"

2" 3'

8"

2"

FG #1

6" th re e in ch es o ne fo ot

6" th re e qu ar te rs in ch o ne fo ot

6" on e in ch o ne fo ot on e an d on e ha lf in ch es o ne fo ot on e ha lf in ch o ne fo ot

6" th re e ei gh th s in ch o ne fo ot on e ei gh th in ch o ne fo ot on e qu ar te r i nc h on e fo ot 1 2 3 4 5

Drawing Title:Seal:

FULLY SPRINKLERED

ARCHITECT / ENGINEERS:

Project Title:

Date:

Project Number:

Drawing Number:

Drawn:Checked:

Building Number:

D C

B A

Revisions:

8016 TOWER POINT DRIVE

CHARLOTTE, NC 28227

P 704.814.1320 F 704.321.0833

Project Phase:

D C

B A

1 2 3 4 5 6

Location:

CONSULTANTS:

Office of

Construction and Facilities Management

MAIN OFFICE

BIM 360://16009 Alexandria Boiler Plant/16009 - ARCH - R2018.rvt

HDG PROJECT: 16009 AE601

DOOR SCHEDULES & WINDOW

LOUVER DETAILS

BID DOCUMENTS

REPLACE BOILER PLANT &

STEAM DISTRIBUTION

SYSTEM

JUNE 14, 2019

ALEXANDRIA VA HEALTH CARE SYSTEM

PINEVILLE, LA

502-14-102V

DOOR SCHEDULE

DOOR NO SIZE

DOOR FRAME

RATING HW SIGN REMARKSTYPE MAT'L TYPE MAT'L

1A100.1 YY 2 HM 1 HM SH-9 CR

1A100.5 S 2 HM 1 HM SH-3 CR

1A100.6 S 8 HM 1 HM 90 MIN. SH-3D CR

1A100.7 S 8 HM 1 HM 90 MIN. 1R

1A101.2 S 2 HM 1 HM 5

1A103.1 S 1 WD 1 HM 5G

1A104.1 S 1 WD 1 HM 2

1A105.1 S 1 WD 1 HM 3E

1A106.1 S 7 WD 1 HM 90 MIN. 3H

1A106.2 S 7 WD 1 HM 90 MIN. 3H

1A107.1 S 1 WD 1 HM 5D CR

1A108.1 S 1 WD 1 HM 3E

1A109.1 S 4 WD 1 HM 5

1A111.1 S 8 HM 1 HM 90 MIN. 5

1A113.1 S 1 WD 1 HM 5

1A116.1 S 2 HM 1 HM 11

E3 SS 2 HM 1 HM SH-9 CR

E4 SS 2 HM 1 HM SH-9

E5 SS 2 HM 1 HM SH-9

E6 S 2 HM 1 HM SH-3 CR

1/4" = 1'-0"

C2 DOOR AND FRAME TYPES

W2

DOOR SYMBOL LEGEND

1/4" = 1'-0"

D5 LOUVERS

1/4" = 1'-0"

D3 HOLLOW METAL WINDOW ELEVATIONS

W1

02.68 INFILL EXISTING WALL OPENING WITH MASONRY -

SEE STRUCTURAL (TYP) AND ADD LAYERS OF GWB

TO FLUSH WITH ADJACENT FINISH.

- SHEET KEYNOTES

2'0 4' 8'2'0 4' 8'

MG #1 LAMINATED SAFETY GLASS, BLAST RESISTANT. BASIS OF DESIGN: KRIEGER WIN - KBR -3.0 (WITH CUSTOM FRAME)

FG #1 FIRELITE GLASS - RATED 2 HOURS

IG #1 SEE SPEC SECTION 08 52 13

GLAZING TYPE CLARIFICATION

W3

OCTOBER 18, 2019

No. Description Date

1 Amendment 2 2/03/2020 2 Amendment 6 4/09/2020 3 Amendment 7 4/21/2020

EXCEPT FOR DELETION OF COILING

DOORS AND GRILLES 1A100.2,

1A100.3, AND 1A100.4, DOOR

SCHEDULE IS REVISED TO REVERT

TO PREVIOUS AMENDMENT 2.

AE601 Amendment 7.pdf
Sheets
AE601 - DOOR SCHEDULES & WINDOW LOUVER DETAILS
AE601 Amendment 7.pdf
Sheets
AE601 - DOOR SCHEDULES & WINDOW LOUVER DETAILS