36C10F19R0040-020.pdf
PDF 1 MB Posted
- Attached to
- WESTERN NEW YORK NATIONAL CEMETERY PHASE 1A Federal contract opportunity
- Solicitation number
- 36C10F19R0040
About this file
36C10F19R0040 C27 936PC2002_WNYNC_445-447-DWG.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C10F19C0015-000.docx | DOCX document | |
| 36C10F19R0040-0002001.pdf | ||
| 36C10F19R0040-0002002.pdf | ||
| 36C10F19R0040-0002000.docx | DOCX document | |
| 36C10F19R0040-002.docx | DOCX document | |
| 36C10F19R0040-013.pdf | ||
| 36C10F19R0040-008.pdf | ||
| 36C10F19R0040-014.pdf | ||
| 36C10F19R0040-011.pdf | ||
| 36C10F19R0040-012.pdf | ||
| 36C10F19R0040-009.pdf | ||
| 36C10F19R0040-003.docx | DOCX document | |
| 36C10F19R0040-007.pdf | ||
| 36C10F19R0040-006.pdf | ||
| 36C10F19R0040-010.pdf | ||
| 36C10F19R0040-004.pdf | ||
| 36C10F19R0040-017.pdf | ||
| 36C10F19R0040-018.pdf | ||
| 36C10F19R0040-019.pdf | ||
| 36C10F19R0040-016.pdf | ||
| 36C10F19R0040-005.pdf | ||
| 36C10F19R0040-015.pdf | ||
| 36C10F19R0040-001.docx | DOCX document |
Show all 23
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
F
F
F
F
F
F
F
F
F
F
F
F
F
F W
F W
F
F W
F
F F
F
F W F
W
F
F W
F W
F W
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
FF
F
F
FW
F W
F
F
F W
FIRE ALARM CABLING SHALL BE INSTALLED IN CONDUIT WHERE PLENUM RATED CABLING IS
NOT UTILIZED.
A.
FIRE ALARM GENERAL NOTES
PROVIDE DUCT SMOKE DETECTOR WITHIN 5' OF EACH FIRE/SMOKE DAMPER WITH
CONNECTION TO LOCAL FIRE ALARM SYSTEM. ALARM OF DUCT DETECTOR SHALL ACTIVATE
DAMPER.
B.
3.A
A.A
B.A
4.A
HAC
A-121
MEN'S
A-113
WOMEN'S
A-112
INFORMATION
A-123
RECYCLE
A-104
LOCKERS
A-128
SEATING
A-106
SECURE STORAGE
A-127
PASSAGE
A-114
DATA / I.T.
A-117
MEN'S
A-101
ELECTRICAL
A-118
DIRECTOR
A-111
ASST. DIRECTOR
A-115
MECHANICAL
A-119
VESTIBULE
A-122
ALCOVE
A-130
FAMILY RESTROOM
A-102
Space
OPEN OFFICE
A-105
GEN. STORAGE
A-116
CORRIDOR
A-110
CORRIDOR
A-107
GRAVE LOC. CL.
A-125
WOMEN'S
A-103
VESTIBULE
A-126
RECEPTION
A-124
LOBBY
A-100
OPERATIONAL CENTER
A-109
MULTI-PURPOSE
A-108LUNCH ROOM
A-120
FACP
WP1.C
A.C
4.C
B.C
2.C 3.C
VAULT
C-108
MECHANICAL
C-104
PORCH
C-100
CLOSET
C-107
WOMEN'S
C-105
MEN'S
C-106
LOCKER
C-102
PASSAGE
C-109
STORAGE
C-103
HONOR GUARD
C-101
FACP
WP
1.D
E.D
B.D
G.D
7.D
D.D
C.D
2.D 3.D 4.D 5.D 6.D
A.D
F.D
9.D 11.D 14.D 16.D
BOOT WASH (EXT)
D-124
BOOT HOLDING / WASH
D-109
COTR OFFICE
D-103
CARETAKER WORKSTATIONS
D-102
ELECTRICAL
D-110
CORRIDOR
D-126
H.A.C.
D-101
ALCOVE
D-128
Space
MULTI-PURPOSE ROOM
D-106
FOREMAN
D-105
STORAGE RM
D-115
CORRIDOR
D-127
ALCOVE
D-125
HR & LINK
D-104
CORRIDOR
D-100
WOMEN'S
D-116
Space
LOCKER RM
D-118
TELECOM
D-113
MEN'S
D-117
PARTS & TOOL STORAGE
D-112
MECHANICAL
D-120
WASH BAY
D-123
VEHICLE - EQUIP
D-121
WORK AREA
D-119
VEHICLE - EQUIP STORAGE
D-122
FAA
FACP
5.1D 6.1E 6.2E
WP
WP
WP
WP
1.D
E.D
B.D
G.D
7.D
D.D
C.D
2.D 3.D 4.D 5.D 6.D 9.D
MEZZANINE
D-201
MECHANICAL
D-202
VEHICLE - EQUIP
D-121
WASH BAY
D-123
VEHICLE - EQUIP STORAGE
D-122
5.1D 6.1E 6.2E
P R O F E S S
IO
NA
L EL
ECTRICA
L
E N G
IN
E E R
S
T
ATE OF NEBR
AS
K
A
E-11812
BURNHAM
KRISTOPHER S.
DO NOT SCALE DRAWING. ALL DIMENSIONS AND CLEARANCES SHALL
BE VERIFIED FROM APPROPRIATE SOURCES. ALL WORK SHALL BE
COORDINATED PRIOR TO INSTALLATION. SEE SPECIFICATIONS.
C COPYRIGHT
PERMISSION TO REPRODUCE ANY PART OF THIS DOCUMENT IS HEREBY
GRANTED SOLELY FOR THE PURPOSE OF THE CONSTRUCTION OF THE
PROJECT OR THE ARCHIVING OF THIS PROJECT. UNAUTHORIZED USE
OF THIS DOCUMENT WITHOUT THE WRITTEN PERMISSION OF SPECIALIZED
ENGINEERING SOLUTIONS IS PROHIBITED BY COPYRIGHT LAW.
www.specializedeng.com
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520
SES PROJECT #
B
A
C
D
E
F
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
BID DOCUMENTS
ATIONAL
EMETERY
DMINISTRATIONA
C
N
Drawing Title
GENESEE COUNTY, NEW YORK
Project Title
Location
Date Checked Drawn
936PC2002
Drawing Number
Building Number
Project Number
Management
03-15-19 Dwg of
V
T
N T I
D
STA
E
U
E
N T
OF
I
C
ES OF
R I
AM
E
R
A
S
S
ETERAN
AF
F A
Revisions:
VA FORM 08-6231, OCT 1978
CONSULTANTS:
Date
ARCHITECT/ENGINEER:
ATIONAL
EMETERY
DMINISTRATIONA
C
N
WESTERN NEW YORK
NATIONAL CEMETERY
PHASE 1A DEVELOPMENT and Facilities
Office of
Construction
LEO A DALY Company 2017
16132
03/15/19?
/2
/2
:0
:1 P
M C
R e v it L o c a l\ V
A C e m e te ry S
E S n e n g e lN
S
B S
.r v t
FA101
LEVEL ONE - FIRE ALARM PLANS
KSB JSH
LEVEL ONE - FIRE ALARM PLANS
1/8" = 1'-0"
ADMIN/PIC - BUILDING 1001 - FIRE ALARM PLAN
1/8" = 1'-0"
HONOR GUARD - BUILDING 3401 - FIRE ALARM PLAN
1/8" = 1'-0"
MAINTENANCE - BUILDING 3001 - GROUND FLOOR FIRE ALARM
PLAN
1/8" = 1'-0"
MAINTENANCE - BUILDING 3001 - LEVEL 2 FIRE ALARM PLAN
ADD ALTERNATE #1
N.I.C.N.I.C.
FIRE ALARM SYSTEM SYMBOL LEGEND
SYSTEM SMOKE DETECTOR - CEILING STROBE - CEILING
HORN - CEILING
SYSTEM DUCT SMOKE DETECTOR
SPEAKER - CEILING
FIRE FIGHTER'S TELEPHONE JACK
FIRE ALARM REMOTE ANNUNCIATOR BELL - CEILING
MANUAL STATION
SMOKE DAMPER OR FIRE/SMOKE DAMPER
PLAN SYMBOL DEVICE
DEVICE
MODEL NO.
ROUGH-IN GANG QTY
BOX TYPE BOX DEPTH CONDUIT SIZE
CONDUIT STUB LOCATION
CIRCUIT FIRE SMOKE DAMPERS TO 20A 120V LIFE SAFETY BRANCH CIRCUITS IN LOCAL LIFE SAFETY BRANCH PANEL OF THE ASSOCIATED CONSTRUCTION PHASE (INSTALL CIRCUIT BREAKER LOCK ON BRANCH BREAKERS). PROVIDE INDIVIDUAL CIRCUITS FOR EACH AIR HANDLING UNIT ZONE. REFER TO MECHANICAL PLANS FOR ASSOCIATED ZONES. CONTROL EACH DAMPER INDIVIDUALLY WITH ADDRESSABLE CONTROL MODULES FROM FIRE ALARM SYSTEM. PROVIDE SYSTEM DUCT SMOKE DETECTOR IN ACCESSIBLE LOCATION WITHIN 5 FEET OF THE DAMPER. INCLUDE REMOTE STATUS AND TEST STATION FOR DETECTOR AND COORDINATE ASSOCIATED MOUNTING LOCATION WITH OWNER.
ELEVATION
GENERAL
DETAILED
F
SYSTEM HEAT DETECTOR - CEILING
F
F HORN & STROBE COMBINATION - CEILING
F
FF
SPEAKER & STROBE COMBINATION - CEILINGF
CHIME - CEILINGF
FA-ANN
F CHIME & STROBE COMBINATION - CEILING
F
BELL & STROBE COMBINATION - CEILINGFF
CONTROL MODULEF CM
MONITORING MODULEF MM
SD
FSD
WP
MAGNETIC DOOR HOLDER -- -- -- -- -- -- --
CIRCUIT MAGNETIC DOOR HOLDER FROM FIRE ALARM SYSTEM AT SYSTEM VOLTAGE. COORDINATE PRODUCT AND INSTALLATION LOCATION WITH ASSOCIATED DOOR HARDWARE.
PROVIDE SYSTEM SMOKE DETECTOR WITHIN 5 FEET OF DOOR OPENING ON EACH SIDE (UNLESS SHOWN WITH ROOM DETECTION COVERAGE ON PLAN).
WEATHER-PROOF ENCLOSURE
SYSTEM SMOKE DETECTOR - CEILING - WITH SOUNDER BASE
SINGLE STATION SMOKE ALARM - CEILING
STROBE INTEGRAL TO SMOKE DETECTOR
SS
SB
ST
WHERE INFORMATIONAL CELLS OF THE DETAILED SYMBOLS ABOVE ARE BLANK, COORDINATE EXACT REQUIREMENTS WITH MANUFACTURER, FIELD CONDITIONS, PLANS AND SPECIFICATIONS.
DETAIL
CIRCUIT CONTROL PANEL TO 20A 120V LIFE SAFETY BRANCH CIRCUIT IN LOCAL LIFE SAFETY BRANCH PANEL OF THE ASSOCIATED CONSTRUCTION PHASE (INSTALL CIRCUIT BREAKER LOCK ON BRANCH BREAKER). PROVIDE SYSTEM SMOKE DETECTOR AT CEILING WITHIN 5 FEET OF PANEL (UNLESS SHOWN WITH ROOM DETECTION COVERAGE ON PLAN).
FACP
FIRE ALARM CONTROL PANEL
W WALL MOUNTED (IN LIEU OF CEILING MOUNTING REFERENCED ABOVE)
FACP
POWER
SUPPLY
FIRST/SECOND LEVEL
F
GENERAL NOTES:
1. DEVICES ARE SHOWN FOR GENERAL CLARIFICATION. REFER TO
PLAN FOR QUANTITIES AND LOCATIONS.
F F
FF
FACP
POWER
SUPPLY
FIRST LEVEL
F
GENERAL NOTES:
1. DEVICES ARE SHOWN FOR GENERAL CLARIFICATION. REFER TO
PLAN FOR QUANTITIES AND LOCATIONS.
F F
FF
FACP
POWER
SUPPLY
FIRST LEVEL
F
GENERAL NOTES:
1. DEVICES ARE SHOWN FOR GENERAL CLARIFICATION. REFER TO
PLAN FOR QUANTITIES AND LOCATIONS.
F F
FF
P R O F E S S
IO
NA
L EL
ECTRICA
L
E N G
IN
E E R
S
T
ATE OF NEBR
AS
K
A
E-11812
BURNHAM
KRISTOPHER S.
DO NOT SCALE DRAWING. ALL DIMENSIONS AND CLEARANCES SHALL
BE VERIFIED FROM APPROPRIATE SOURCES. ALL WORK SHALL BE
COORDINATED PRIOR TO INSTALLATION. SEE SPECIFICATIONS.
C COPYRIGHT
PERMISSION TO REPRODUCE ANY PART OF THIS DOCUMENT IS HEREBY
GRANTED SOLELY FOR THE PURPOSE OF THE CONSTRUCTION OF THE
PROJECT OR THE ARCHIVING OF THIS PROJECT. UNAUTHORIZED USE
OF THIS DOCUMENT WITHOUT THE WRITTEN PERMISSION OF SPECIALIZED
ENGINEERING SOLUTIONS IS PROHIBITED BY COPYRIGHT LAW.
www.specializedeng.com
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520
SES PROJECT #
B
A
C
D
E
F
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
BID DOCUMENTS
ATIONAL
EMETERY
DMINISTRATIONA
C
N
Drawing Title
GENESEE COUNTY, NEW YORK
Project Title
Location
Date Checked Drawn
936PC2002
Drawing Number
Building Number
Project Number
Management
03-15-19 Dwg of
V
T
N T I
D
STA
E
U
E
N T
OF
I
C
ES OF
R I
AM
E
R
A
S
S
ETERAN
AF
F A
Revisions:
VA FORM 08-6231, OCT 1978
CONSULTANTS:
Date
ARCHITECT/ENGINEER:
ATIONAL
EMETERY
DMINISTRATIONA
C
N
WESTERN NEW YORK
NATIONAL CEMETERY
PHASE 1A DEVELOPMENT and Facilities
Office of
Construction
LEO A DALY Company 2017
16132
03/15/19?
/2
/2
:0
:1 P
M C
R e v it L o c a l\ V
A C e m e te ry S
E S n e n g e lN
S
B S
.r v t
FA102
FIRE ALARM RISER DIAGRAM
KSB JSH
FIRE ALARM RISER DIAGRAM
1/8" = 1'-0"
FIRE ALARM SYSTEM SYMBOL LEGEND
NOT TO SCALE
FIRE ALARM RISER DIAGRAM - MAINTENANCE BUILDING 3001
NOT TO SCALE
FIRE ALARM RISER DIAGRAM - ADMIN/PIC BUILDING 1001
NOT TO SCALE
FIRE ALARM RISER DIAGRAM - HONOR GAURD BUILDING 3401
1 VE OPTION NO. 6
N.I.C.
3.A
A.A
B.A
4.A
HAC
A-121
MEN'S
A-113
WOMEN'S
A-112
INFORMATION
A-123
RECYCLE
A-104
LOCKERS
A-128
SEATING
A-106
SECURE STORAGE
A-127
PASSAGE
A-114
DATA / I.T.
A-117
MEN'S
A-101
ELECTRICAL
A-118
DIRECTOR
A-111
ASST. DIRECTOR
A-115
MECHANICAL
A-119
VESTIBULE
A-122
ALCOVE
A-130
FAMILY RESTROOM
A-102
Space
OPEN OFFICE
A-105
GEN. STORAGE
A-116
CORRIDOR
A-110
CORRIDOR
A-107
GRAVE LOC. CL.
A-125
WOMEN'S
A-103
VESTIBULE
A-126
RECEPTION
A-124
LOBBY
A-100
OPERATIONAL CENTER
A-109
MULTI-PURPOSE
A-108
LUNCH ROOM
A-120
1.D
E.D
B.D
G.D
7.D
D.D
C.D
2.D 3.D 4.D 5.D 6.D
A.D
F.D
9.D 11.D 14.D 16.D
BOOT WASH (EXT)
D-124
BOOT HOLDING / WASH
D-109
COTR OFFICE
D-103
CARETAKER WORKSTATIONS
D-102
ELECTRICAL
D-110
CORRIDOR
D-126
H.A.C.
D-101
ALCOVE
D-128
Space
MULTI-PURPOSE ROOM
D-106
FOREMAN
D-105
STORAGE RM
D-115
CORRIDOR
D-127
ALCOVE
D-125
HR & LINK
D-104
CORRIDOR
D-100
WOMEN'S
D-116
Space
LOCKER RM
D-118
TELECOM
D-113
MEN'S
D-117
PARTS & TOOL STORAGE
D-112
MECHANICAL
D-120
WASH BAY
D-123
VEHICLE - EQUIP
D-121
WORK AREA
D-119
VEHICLE - EQUIP STORAGE
D-122
1.C
A.C
4.C
B.C
2.C 3.C
VAULT
C-108
MECHANICAL
C-104
PORCH
C-100
CLOSET
C-107
WOMEN'S
C-105
MEN'S
C-106
LOCKER
C-102
PASSAGE
C-109
STORAGE
C-103
HONOR GUARD
C-101
1.D
E.D
B.D
G.D
7.D
D.D
C.D
2.D 3.D 4.D 5.D 6.D 9.D
MEZZANINE
D-201
MECHANICAL
D-202
VEHICLE - EQUIP
D-121
WASH BAY
D-123
VEHICLE - EQUIP STORAGE
D-122
GENERAL ABBREVIATIONS
ABBREVIATION DESCRIPTION
AD ACCESS DOOR/PANEL
AFF ABOVE FINISHED FLOOR
AMB AMBIENT
DIA DIAMETER
DN DOWN
E EXISTING
EC ELECTRICAL CONTRACTOR
EFF EFFICIENCY
GC GENERAL CONTRACTOR
FPM FEET PER MINUTE
FPS FEET PER SECOND
L LENGTH
LF LINEAR FEET
MAX MAXIMUM
MC MECHANICAL CONTRACTOR
MFR MANUFACTURER
MIN MINIMUM
NIC NOT IN CONTRACT
NTS NOT TO SCALE
PC PLUMBING CONTRACTOR
PSIG POUNDS PER SQUARE INCH GAUGE
RPM REVOLUTIONS PER MINUTE
SHT SHEET
TOB TOP OF BEAM
GPM GALLONS PER MINUTE
ABBREVIATION DESCRIPTION
TOS TOP OF STEEL
BOB BOTTOM OF BEAM
VEL VELOCITY
VFD VARIABLE FREQUENCY DRIVE
NOT ALL ABBREVIATIONS APPLY TO THIS SET OF DOCUMENTS.
FIRE PROTECTION ABBREVIATIONS
ABBREVIATION DESCRIPTION
FS FLOW SWITCH
F FIRE PROTECTION
ABBREVIATION DESCRIPTION
BFP BACK FLOW PREVENTER
FDC FIRE DEPARTMENT CONNECTION
PIV POST INDICATOR VALVE
SPR SPRINKLER
NOT ALL ABBREVIATIONS APPLY TO THIS SET OF DOCUMENTS.
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
FIRE PROTECTION WORK SHALL INCLUDE, BUT NOT LIMITED TO, THE FOLLOWING:
ALL AREAS OF THE BUILDING INDICATED SHALL BE SPRINKLERED ACCORDING TO
THE CURRENTLY ADOPTED EDITION OF NFPA STANDARD 13 AND OTHER NFPA
STANDARDS AS REQUIRED. ENTIRE SYSTEM SHALL BE INSTALLED IN
ACCORDANCE WITH THE REQUIREMENTS OF THE STATE FIRE MARSHAL OFFICE,
OWNER'S INSURANCE COMPANY AND AUTHORITIES HAVING JURISDICTION.
FIRE SPRINKLER DESIGN SHALL BE BASED ON HYDRAULIC CALCULATIONS
ACCORDING NFPA 13, WITH SHOP DRAWINGS PREPARED ACCORDING TO THE
REQUIREMENTS OF THE STATE FIRE MARSHAL AND AUTHORITIES HAVING
JURISDICTION.
SPRINKLER CONTRACTOR SHALL OBTAIN STATIC AND RESIDUAL WATER
PRESSURE AND FLOW PRIOR TO SYSTEM DESIGN AND SHALL SUBMIT RECENT
HYDRANT FLOW TEST DATA WITH SHOP DRAWING SUBMITTALS.
DRAWINGS ARE SCHEMATIC IN NATURE, INTENDED TO CONVEY THE SCOPE OF
WORK AND GENERAL ARRANGEMENT OF THE SYSTEM. SPRINKLER SYSTEM
INSTALLING CONTRACTOR SHALL COORDINATE SYSTEM ARRANGEMENT WITH
ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL COMPONENTS.
SPRINKLER PIPING SHALL NOT BE INSTALLED BELOW MECHANICAL EQUIPMENT
OR WITHIN CLEARANCE SPACES FOR MECHANICAL EQUIPMENT. PROVIDE
SPRINKLER PROTECTION BELOW ALL DUCTS GREATER THAN 48 INCHES IN
WIDTH. INSTALLING CONTRACTOR SHALL BE RESPONSIBLE FOR ANY
MODIFICATIONS TO THE SYSTEM REQUIRED TO AVOID CONFLICTS.
AREAS IDENTIFIED INDICATE THE RECOMMENDED MINIMUM OCCUPANCY
CLASSIFICATION, SPRINKLER TEMPERATURE CHARACTERISTIC OR SPRINKLER
TYPES TO BE INSTALLED. SPRINKLER SYSTEM SHALL BE DESIGNED TO MEET OR
EXCEED THESE RECOMMENDATIONS AND SHALL BE SUBJECT TO APPROVAL BY
THE AUTHORITY HAVING JURISDICTION.
A PRE-DESIGN MEETING SHALL BE COORDINATED WITH THE ARCHITECT PRIOR
TO SUBMITTAL OF PIPING LAYOUT DRAWINGS. ARCHITECT SHALL ISSUE
COMMENTS CONCERNING SUBMITTAL PACKAGE PRIOR TO COMMENCEMENT OF
WORK.
REFER TO ARCHITECTURAL PLANS FOR SPECIFIC CEILING TYPES AND HEIGHTS,
AND AREAS OF EXPOSED STRUCTURE.
COORDINATE PIPING AND SPRINKLERS IN EXPOSED AREAS TO MINIMIZE
APPEARANCE. INSTALL SPRINKLERS A MINIMUM OF SIX INCHES FROM
DIFFUSERS, GRILLES AND LIGHT FIXTURES. INSTALL SPRINKLERS IN LAY-IN
CEILINGS WITHIN THREE INCHES OF THE CENTER OF CEILING TILE.
COORDINATE INSTALLATION OF SPRINKLERS AND PIPING SYSTEMS TO AVOID
FREEZING CONDITIONS. NOTIFY ARCHITECT OF AREAS FOR WHERE SYSTEM MAY
BE EXPOSED TO FREEZING. INSTALL DRY SIDEWALL SPRINKLERS IN ROOMS
INDICATED WHERE ROOMS MAY BE UNCONDITIONED OR EXPOSED TO FREEZING
CONDITIONS. PROVIDE AUXILIARY DRAINS WHERE REQUIRED.
EXPOSED SPRINKLER PIPING, EXCEPT IN MECHANICAL AND STORAGE ROOMS,
SHALL BE CLEANED, PRIMED AND PREPARED FOR PAINTING.
WHERE SPRINKLER PIPING SYSTEM PENETRATES FIRE RESISTIVE RATED
ASSEMBLIES, SEAL OPENINGS WITH APPROVED CONSTRUCTION METHODS AND
MATERIALS.
AVOID ROUTING SPRINKLER PIPING ABOVE ELECTRICAL, DATA, IT AND
COMMUNICATION PANELS.
FIRE PROTECTION GENERAL NOTES
F
FIRE PROTECTION SYMBOLS
SYMBOL DESCRIPTION ADDITIONAL REMARKS
FLOW SWITCH
FIRE DEPARTMENT CONNECTION MOUNT BETWEEN 18" AND 48" ABOVE FINISHED GRADE
UPRIGHT SPRINKLER
PENDANT SPRINKLER
CONCEALED SPRINKLER
SIDEWALL SPRINKLER
REFER TO SPECIFICATIONS FOR TYPES AND FINISHES.
PENDANT REFERS TO FULL, SEMI-RECESSED AND RECESSED TYPES. LOCATIONS
FOR EACH ARE INDICATED IN THE SPECIFICATIONS OR ON THE PLANS.
COORDINATE INTERFACE WITH FIRE ALARM SYSTEM CONTRACTOR
P R O F E S S
IO
NA
L EL
ECTRICA
L
E N G
IN
E E R
S
T
ATE OF NEBR
AS
K
A
E-11812
BURNHAM
KRISTOPHER S.
DO NOT SCALE DRAWING. ALL DIMENSIONS AND CLEARANCES SHALL
BE VERIFIED FROM APPROPRIATE SOURCES. ALL WORK SHALL BE
COORDINATED PRIOR TO INSTALLATION. SEE SPECIFICATIONS.
C COPYRIGHT
PERMISSION TO REPRODUCE ANY PART OF THIS DOCUMENT IS HEREBY
GRANTED SOLELY FOR THE PURPOSE OF THE CONSTRUCTION OF THE
PROJECT OR THE ARCHIVING OF THIS PROJECT. UNAUTHORIZED USE
OF THIS DOCUMENT WITHOUT THE WRITTEN PERMISSION OF SPECIALIZED
ENGINEERING SOLUTIONS IS PROHIBITED BY COPYRIGHT LAW.
www.specializedeng.com
10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520
SES PROJECT #
B
A
C
D
E
F
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
BID DOCUMENTS
ATIONAL
EMETERY
DMINISTRATIONA
C
N
Drawing Title
GENESEE COUNTY, NEW YORK
Project Title
Location
Date Checked Drawn
936PC2002
Drawing Number
Building Number
Project Number
Management
03-15-19 Dwg of
V
T
N T I
D
STA
E
U
E
N T
OF
I
C
ES OF
R I
AM
E
R
A
S
S
ETERAN
AF
F A
Revisions:
VA FORM 08-6231, OCT 1978
CONSULTANTS:
Date
ARCHITECT/ENGINEER:
ATIONAL
EMETERY
DMINISTRATIONA
C
N
WESTERN NEW YORK
NATIONAL CEMETERY
PHASE 1A DEVELOPMENT and Facilities
Office of
Construction
LEO A DALY Company 2017
16132
03/15/19?
/2
/2
:0
:2 P
M C
R e v it L o c a l\ V
A C e m e te ry S
E S n e n g e lN
S
B S
.r v t
FP101
LEVEL ONE - FIRE PROTECTION
PLANS
FEG JSH
LEVEL ONE - FIRE PROTECTION
PLANS
1001, 3001, 3401
1/8" = 1'-0"
ADMIN/PIC - BUILDING 1001 - FIRE SPRINKLER PLAN
1/8" = 1'-0"
MAINTENANCE - BUILDING 3001 - GROUND FLOOR FIRE
SPRINKLER PLAN
1/8" = 1'-0"
HONOR GUARD - BUILDING 3401 - FIRE SPRINKLER PLAN
1/8" = 1'-0"
MAINTENANCE - BUILDING 3001 - LEVEL 2 FIRE SPRINKLER PLANS
N.I.C.N.I.C.
| 445_FA101 - LEVEL ONE - FIRE ALARM PLANS |
| Sheets |
| FA101 - LEVEL ONE - FIRE ALARM PLANS |
| FA102 - FIRE ALARM RISER DIAGRAM |
| FP101 - LEVEL ONE - FIRE PROTECTION PLANS |
| 446_FA102 - FIRE ALARM RISER DIAGRAM |
| Sheets |
| FA101 - LEVEL ONE - FIRE ALARM PLANS |
| FA102 - FIRE ALARM RISER DIAGRAM |
| FP101 - LEVEL ONE - FIRE PROTECTION PLANS |
| 447_FP101 - LEVEL ONE - FIRE PROTECTION PLANS |
| Sheets |
| FA101 - LEVEL ONE - FIRE ALARM PLANS |
| FA102 - FIRE ALARM RISER DIAGRAM |
| FP101 - LEVEL ONE - FIRE PROTECTION PLANS |
File details come from the government source that posted it.