MAR 2026 EQ - Schedule of Line Items with Vendor QA.xlsx

XLSX spreadsheet 64 KB Posted

Attached to
6525--MAR 2026 Equipment Only Consolidation
Solicitation number
36A79726Q0009
Issued by

About this file

This is a Schedule of Line Items with Vendor Quality Assurance for the March 2026 Equipment Only Consolidation solicitation issued by the Department of Veterans Affairs National Acquisition Center under solicitation number 36A79726Q0009. The spreadsheet functions as a procurement template that outlines equipment line items available for acquisition, paired with vendor quality assurance requirements and specifications. The document appears to structure equipment offerings by category with associated vendor performance standards and quality control parameters to ensure that selected vendors meet VA standards for equipment delivery and compliance. This consolidation effort consolidates equipment procurement requirements across the VA enterprise into a single solicitation vehicle to streamline purchasing and ensure standardized quality assurance protocols across all equipment acquisitions under this March 2026 procurement action.

View the file

Other files

File Type Posted
589B63006 - 626B64007.zip ZIP file
504B63005 - 589B63005.zip ZIP file
626B64014 - 5086B6002.zip ZIP file
Amendment 0001 - Continuation Page.pdf PDF
36A79726Q0009 0001.docx DOCX document
VA Directive 6550 - New Appendix A - published Jun. 2023.pdf PDF
36A79726Q0009_1.docx DOCX document
589B63006 - 646B362003.zip ZIP file
MAR 2026 EQ - Schedule of Line Items with QA Template.xlsx XLSX spreadsheet
504B67001 - 589B63005.zip ZIP file
Vendor Workup - 36A79726Q0009.xlsx XLSX spreadsheet
Memorandum for Training.pdf PDF
Vendor Folders.zip ZIP file
649B62004 - 5086B6002.zip ZIP file
MAR 2026 EQ Consolidation - RFO.pdf PDF
MAR 2026 Equipment Only Consolidation Schedule.docx DOCX document
Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SCHEDULE OF LINE ITEMS

HTME VISNSTATIONEQUIPMENT POEQUIPMENT TYPEQTY
VISN 17: VA Heart of Texas Health Care Network504 AMARILLO, TX504B67001XR PORT C ARM1
VISN 10: VA Healthcare System of Ohio506 ANN ARBOR, MI506B60017XR US1NOTE: Row 2 is intentionally skipped.
VISN 07: VA Southeast Health Care Network508 DECATUR, GA5086B6001XR US1The List of Requirements start with Row 3.
VISN 07: VA Southeast Health Care Network508 DECATUR, GA5086B6002XR US4
VISN 05: VA Capitol Health Care Network512 BALTIMORE, MD512B61001XR US3
VISN 08: VA Sunshine Healthcare Network516 BAY PINES, FL516B50008XR US1
VISN 08: VA Sunshine Healthcare Network516 BAY PINES, FL516B60003NM BONE DEN1
VISN 08: VA Sunshine Healthcare Network516 BAY PINES, FL516B60004NM BONE DEN1
VISN 02: VA Healthcare Network Upstate New York526 BRONX, NY526B60006XR US2
VISN 02: VA Healthcare Network Upstate New York528 BUFFALO, NY528B60173XR US1
VISN 02: VA Healthcare Network Upstate New York528 BUFFALO, NY528B60174XR US1
VISN 02: VA Healthcare Network Upstate New York528 BUFFALO, NY528B60230XR US2
VISN 02: VA Healthcare Network Upstate New York528 ALBANY, NY528B63005XR US1
VISN 07: VA Southeast Health Care Network534 CHARLESTON, SC534B62015XR US1
VISN 10: VA Healthcare System of Ohio539 CINCINNATI, OH539B60017XR US1
VISN 10: VA Healthcare System of Ohio539 CINCINNATI, OH539B60023XR US3
VISN 12: VA Great Lakes Health Care System556 NORTH CHICAGO, IL556B61009XR US1
VISN 06: VA Mid-Atlantic Health Care Network558 GREENVILLE, NC558B69005NM BONE DEN1
VISN 12: VA Great Lakes Health Care System578 HINES, IL578B68006XR PORT C ARM1
VISN 10: VA Healthcare System of Ohio583 INDIANAPOLIS, IN583B60005XR US2
VISN 12: VA Great Lakes Health Care System585 IRON MOUNTAIN, MI585B63001XR RAD1
VISN 15: VA Heartland Network589 KANSAS CITY, MO589B60001XR US2
VISN 15: VA Heartland Network589 COLUMBIA, MO589B63005XR MRI1
VISN 15: VA Heartland Network589 COLUMBIA, MO589B63006XR US1
VISN 15: VA Heartland Network589 COLUMBIA, MO589B63008XR PORT RAD2
VISN 15: VA Heartland Network589 COLUMBIA, MO589B63014XR PORT C ARM1
VISN 15: VA Heartland Network589 COLUMBIA, MO589B63015XR US1
VISN 06: VA Mid-Atlantic Health Care Network590 HAMPTON, VA590B69006XR US1
VISN 06: VA Mid-Atlantic Health Care Network590 HAMPTON, VA590B69007XR US1
VISN 21: VA Sierra Pacific Network593 LAS VEGAS, NV593B60001XR HYBRID1
VISN 04: VA Stars & Stripes Healthcare Network595 LEBANON, PA595B69005XR US4
VISN 04: VA Stars & Stripes Healthcare Network595 LEBANON, PA595B69009XR US1
VISN 07: VA Southeast Health Care Network619 MONTGOMERY, AL619B62003XR US4
VISN 07: VA Southeast Health Care Network619 MONTGOMERY, AL619B62004NM BONE DEN1
VISN 09: VA Mid South Healthcare Network621 MOUNTAIN HOME, TN621B60001XR PORT RAD6
VISN 09: VA Mid South Healthcare Network626 MURFREESBORO, TN626B63000XR US1
VISN 09: VA Mid South Healthcare Network626 NASHVILLE, TN626B64007XR US1
VISN 09: VA Mid South Healthcare Network626 NASHVILLE, TN626B64014XR US1
VISN 04: VA Stars & Stripes Healthcare Network642 PHILADELPHIA, PA642B69007XR US1
VISN 04: VA Stars & Stripes Healthcare Network642 PHILADELPHIA, PA642B69010XR US1
VISN 04: VA Stars & Stripes Healthcare Network642 PHILADELPHIA, PA642B69012XR US1
VISN 22: VA Desert Pacific Healthcare Network644 PHOENIX, AZ644B68011XR US1
VISN 04: VA Stars & Stripes Healthcare Network646 PITTSBURGH, PA646B62003XR US5
VISN 22: VA Desert Pacific Healthcare Network649 PRESCOTT, AZ649B62004XR PORT RAD2
VISN 15: VA Heartland Network657 ST LOUIS, MO657B60005XR IR1
VISN 06: VA Mid-Atlantic Health Care Network658 SALEM, VA658B69001XR HYBRID1
VISN 19: VA Rocky Mountain Network660 SALT LAKE CITY, UT660B60001XR PORT RAD1
VISN 21: VA Sierra Pacific Network662 SAN FRANCISCO, CA662B61005XR US1
VISN 20: VA Northwest Network663 SEATTLE, WA663B63007XR US1
VISN 20: VA Northwest Network663 SEATTLE, WA663B63008XR US1
VISN 16: South Central VA Health Care Network667 SHREVEPORT, LA667B69022XR PORT C ARM2
VISN 16: South Central VA Health Care Network667 SHREVEPORT, LA667B69023XR PORT C ARM1
VISN 20: VA Northwest Network668 SPOKANE, WA668B63002XR US2
VISN 17: VA Heart of Texas Health Care Network671 SAN ANTONIO, TX671B60013XR US6
VISN 17: VA Heart of Texas Health Care Network671 SAN ANTONIO, TX671B60026XR RAD1
VISN 08: VA Sunshine Healthcare Network675 ORLANDO, FL675B67003XR US3
VISN 08: VA Sunshine Healthcare Network675 ORLANDO, FL675B67010XR US2
VISN 08: VA Sunshine Healthcare Network675 VIERA, FL675B67011XR MAMMO1
VISN 22: VA Desert Pacific Healthcare Network678 TUCSON, AZ678B61009XR RAD1
VISN 22: VA Desert Pacific Healthcare Network678 TUCSON, AZ678B61011XR US1
VISN 05: VA Capitol Health Care Network688 WASHINGTON, DC688B61000NM SPECT CT1
VISN 05: VA Capitol Health Care Network688 WASHINGTON, DC688B61001NM SPECT CT1
VISN 04: VA Stars & Stripes Healthcare Network693 WILKES-BARRE, PA693B63002XR US6
VISN 12: VA Great Lakes Health Care System695 MILWAUKEE, WI695B68007XR US1
VISN 10: VA Healthcare System of Ohio757 COLUMBUS, OH757B60006XR PORT C ARM1
VISN 10: VA Healthcare System of Ohio757 COLUMBUS, OH757B60010XR US1
General

QA TEMPLATE

EQUIPMENT POVISNSTATIONEQUIPMENT TYPEVENDOR EQUIPMENT QUESTIONSGOVERNMENT EQUIPMENT RESPONSE
528B60230VISN 02: VA Healthcare Network Upstate New York528 BUFFALO, NYXR USSchedule says 2 units, benchmark says 1 unit, and the description says 3 units. Please confirm number of units required
539B60023VISN 10: VA Healthcare System of Ohio539 CINCINNATI, OHXR USSchedule says 3 units, benchmark says 3 units, description says 2 units, and only 2 trade ins. Please confirm number of units
593B60001VISN 21: VA Sierra Pacific Network593 LAS VEGAS, NVXR HYBRIDSection 7. C-arm Specifications. This section competes with rows 20-61 and specifies a floor mounted angio system. Request removal of these requirements as Angio CT systems are equipped with ceiling mounted angio arms.
593B60001VISN 21: VA Sierra Pacific Network593 LAS VEGAS, NVXR HYBRID3.h suggest removing table control from CT scanner as these systems the table doesn’t move during CT exams, the gantry moves.
593B60001VISN 21: VA Sierra Pacific Network593 LAS VEGAS, NVXR HYBRID3.c request changing CT detector z-axis to 160mm to enable whole organ perfusion
589B63014VISN 15: VA Heartland Network589 COLUMBIA, MOXR PORT C ARMMatrix, line 49, Roadmap technology for vascular imaging. This is not a typical spec for a mini c-arm. Can you please confirm this spec is requested, and if this is in fact for a mini c-arm and not a full size c-arm
757B60006VISN 10: VA Healthcare System of Ohio757 COLUMBUS, OHXR PORT C ARMMatrix, Line 43, forward tube source - can this be moved to value add for fair competition?
657B60005VISN 15: VA Heartland Network657 ST LOUIS, MOXR IRPlease Clarify Line 41 3c Neuroradiological needs, including whether a biplane capabilites would be needed, which is common for neuro systems, since the request is for a Single Plane system Line 28 2B?
657B60005VISN 15: VA Heartland Network657 ST LOUIS, MOXR IRPlease clarify Line 36 2i. Do you need a Dual Head or Single Head Injector or any other specifications?
688B61000VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CTPlease amend Line 1a. Minimum number of reconstructed slices to 64.
688B61001VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CTPlease amend Line 1a. Minimum number of reconstructed slices to 64.
688B61000VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CTPlease clarify Line 1e. Are higher range values needed and any special collimators for High Energy and/or pinhole. If the site wants to have a theranostics program with new radioisotopes including Actinium 225, they will need higher energy collimators.
688B61001VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CTPlease clarify Line 1e. Are higher range values needed and any special collimators for High Energy and/or pinhole. If the site wants to have a theranostics program with new radioisotopes including Actinium 225, they will need higher energy collimators.
675B67011VISN 08: VA Sunshine Healthcare Network675 VIERA, FLXR MAMMO1. Technical requirements

Line H: SID 70cm. Please amend for a range of 60cm-70cm. The 70cm SID specification is vendor specific.

675B67011 VISN 08: VA Sunshine Healthcare Network 675 VIERA, FL XR MAMMO 2. Workstation Requirements Line D: Minimum number of review workstations.

Is this for the Radiologist to read mammo studies on-site? If so, what are they currently using to read mammography studies? Hologic’s SecurView reading workstation or a PACS reading workstation?

Do the Rads read remotely?

675B67011 VISN 08: VA Sunshine Healthcare Network 675 VIERA, FL XR MAMMO 3. Additional specifications L. Computer-aided detection (CAD).

What is currently being used for CAD? Or their AI Solution? Is both 2D CAD and 3D CAD required?

675B67011 VISN 08: VA Sunshine Healthcare Network 675 VIERA, FL XR MAMMO Training requirements C. On-site clinical applications training for (2) Physicians during go-live.

What specific clinical applications training for (2) Physicians? Is this for Tomosynthesis training?

675B67011 VISN 08: VA Sunshine Healthcare Network 675 VIERA, FL XR MAMMO Please clarify the following questions in regards to the trade-in: Serial number: SDM131700468 Date of manufacture?

Deinstall date?

Access to site, loading dock available?

System location, Room No.

Other rigging requirements/additional costs?

System in good working condition?

Last tube exchange?

Leased or owned?

Cosmetic appearance?

Average number of patients per day?

Tube in working condition?

Software level?

CAD?

Image Storage Size?

Detector size?

Total number of monitors on the acquisition workstation?

Magnification stand?

Number of paddles (screening)?

Number of paddles (diagnostic)?

Number of spot paddles?

Will hard drive be removed?

Other equipment/options included?

675B67011VISN 08: VA Sunshine Healthcare Network675 VIERA, FLXR MAMMOPlease provide 4-5 pictures of the Hologic Selenia Dimensions 3D mammography system and the acquisition workstation.
589B63014VISN 15: VA Heartland Network589 COLUMBIA, MOXR PORT C ARMPlease Clarify Line 48 3A the need for Vascular Imaging, since mini c.arms only are for extremity imaging ? Are you requesting a Full c.arm?
589B63014VISN 15: VA Heartland Network589 COLUMBIA, MOXR PORT C ARMPlease change Line 29 1J to a minimum of 90,000 foir fair competition
504B67001Please clarify Line 28 1i. the request for a 25kW generator?
504B67001If there a current or future need for 3D cone Beam CT?
671B60026VISN 17: VA Heart of Texas Health Care Network671 SAN ANTONIO, TXXR RADPlease clarify Line 24 1c. , wireless wall detector 10 lbs, when Line 22 1a. states the wall detector is fixed ?
528B60173VISN 02: VA Healthcare Network Upstate New York528 BUFFALO, NYXR USPlease clarify section 8a. Advanced Imaging Tools. Please expand on this request.
667B69023VISN 16: South Central VA Health Care Network667 SHREVEPORT, LAXR PORT C ARMLine 30, 1k. Please lower the minimum generator output power to 2.3kW for fair, open competition
667B69022VISN 16: South Central VA Health Care Network667 SHREVEPORT, LAXR PORT C ARMLine 30, 1k. Please lower the minimum generator output power to 2.3kW for fair, open competition
528B60173VISN 02: VA Healthcare Network Upstate New York528 BUFFALO, NYXR USPlease clarify line 6i, 6j . If possible, please explain if this system will be used for Cardiac Ultrasound.
589B63005VISN 15: VA Heartland Network589 COLUMBIA, MOXR MRIPlease clarify if you would like Venders to include elastography on the mobile MRI?
589B63005VISN 15: VA Heartland Network589 COLUMBIA, MOXR MRIPlease clarify if you would like Venders to include spectroscopy (SVS/MVS/SCI) on the mobile MRI?
593B60001VISN 21: VA Sierra Pacific Network593 LAS VEGAS, NVXR HYBRIDTECHNICAL REQUIREMENTS, Section 2m. – PA gantry minimum cranial-to-caudal angle (deg) of 70/90 single side, 90/120 double side: Question: please explain what is meant by “double side”
593B60001VISN 21: VA Sierra Pacific Network593 LAS VEGAS, NVXR HYBRIDTECHNICAL REQUIREMENTS, Section 4. – General Software Specifications, requirements a – f: Question: are the requirements listed in lines a – f for the Angio system, the CT system or both? Please specify.
593B60001VISN 21: VA Sierra Pacific Network593 LAS VEGAS, NVXR HYBRIDTECHNICAL REQUIREMENTS, Section 6d. – Minimum number of surgical room displays is 2: Question: are each of these monitors to be mounted on a boom? If so, does VA Southern Nevada have a specific OR/boom vendor they utilize for mounting monitors to? Is the size of each these monitors to be at least 55 in.?
593B60001VISN 21: VA Sierra Pacific Network593 LAS VEGAS, NVXR HYBRIDSection 6e. – Minimum surgical monitor size to be 55 in. Question: are each of these monitors to be mounted on a boom? If so, does VA Southern Nevada have a specific OR/boom vendor they utilize for mounting monitors to?
593B60001VISN 21: VA Sierra Pacific Network593 LAS VEGAS, NVXR HYBRIDTECHNICAL REQUIREMENTS, Section 7f. – PA gantry configuration to be Floor-mounted Question: Is the request for a floor-mounted Robotic System in combination with a sliding-gantry CT or a Ceiling-mounted C-arm in combination with sliding-gantry CT? Typically, Angio-CT systems are configured with a Single-Plane Ceiling-mounted system & CT sliding gantry. Please confirm.
593B60001VISN 21: VA Sierra Pacific Network593 LAS VEGAS, NVXR HYBRIDSection 7g. – Floor-mounted on retractable, multi-axis robotic arm Question: Is the request for a floor-mounted Robotic System in combination with a sliding-gantry CT or a Ceiling-mounted C-arm in combination with sliding-gantry CT? Typically, Angio-CT systems are configured with a Single-Plane Ceiling-mounted system & CT sliding gantry. Please confirm.
593B60001VISN 21: VA Sierra Pacific Network593 LAS VEGAS, NVXR HYBRIDSection 7h. – Capable of movement in the sagittal, coronal, and transverse planes Question: Is the request for a floor-mounted Robotic System in combination with a sliding-gantry CT or a Ceiling-mounted C-arm in combination with sliding-gantry CT? Typically, Angio-CT systems are configured with a Single-Plane Ceiling-mounted system & CT sliding gantry. Please confirm.
593B60001VISN 21: VA Sierra Pacific Network593 LAS VEGAS, NVXR HYBRIDSection 7i. – Ability to linearly extend and retract c-arm in sagittal plane Question: Is the request for a floor-mounted Robotic System in combination with a sliding-gantry CT or a Ceiling-mounted C-arm in combination with sliding-gantry CT? Typically, Angio-CT systems are configured with a Single-Plane Ceiling-mounted system & CT sliding gantry. Please confirm.
593B60001VISN 21: VA Sierra Pacific Network593 LAS VEGAS, NVXR HYBRIDSection 7j. – Arm will be fixed and hermitically sealed at foot-unit juncture Question: Is the request for a floor-mounted Robotic System in combination with a sliding-gantry CT or a Ceiling-mounted C-arm in combination with sliding-gantry CT? Typically, Angio-CT systems are configured with a Single-Plane Ceiling-mounted system & CT sliding gantry. Please confirm.
593B60001VISN 21: VA Sierra Pacific Network593 LAS VEGAS, NVXR HYBRIDTECHNICAL REQUIREMENTS, section 13a. – Required formats to be routed is NTSC: Question: Please explain “NTSC”.
516B50008VISN 08: VA Sunshine Healthcare Network516 BAY PINES, FLXR USScanning Modes 3Q. Please confirm if 4D Volume Systolic and Diastolic is needed in the configuration
675B67010VISN 08: VA Sunshine Healthcare Network675 ORLANDO, FLXR USPlease confirm if this system will be used in the ED
590B69006VISN 06: VA Mid-Atlantic Health Care Network590 HAMPTON, VAXR USAdvanced Features 8g. Please clarify the semi-robotic arm, physically attached to biopsy system, with at least 3 degrees of freedom used to stabilize needle and ultrasound probe movements
590B69007VISN 06: VA Mid-Atlantic Health Care Network590 HAMPTON, VAXR USAdvanced Features 8g. Please clarify the semi-robotic arm, physically attached to biopsy system, with at least 3 degrees of freedom used to stabilize needle and ultrasound probe movements
590B69006VISN 06: VA Mid-Atlantic Health Care Network590 HAMPTON, VAXR US9. Security/Connectivity Requirements. Please clarify PACS compatibility- Change Healthcare, VA Vista Imaging
590B69007VISN 06: VA Mid-Atlantic Health Care Network590 HAMPTON, VAXR US9. Security/Connectivity Requirements. Please clarify PACS compatibility- Change Healthcare, VA Vista Imaging
583B60005VISN 10: VA Healthcare System of Ohio583 INDIANAPOLIS, INXR US1.J. Can the battery requirement be moved to value added section?
646B62003VISN 04: VA Stars & Stripes Healthcare Network646 PITTSBURGH, PAXR US1.k. Can the battery requirement be moved to value added section?
646B62003VISN 04: VA Stars & Stripes Healthcare Network646 PITTSBURGH, PAXR US1.M. Can the weight requirement be adjusted to a max weight of 280LBS?
646B62003VISN 04: VA Stars & Stripes Healthcare Network646 PITTSBURGH, PAXR USTrade in- Requirement is for 5 units, but the sheet only shows trading in 4 systems? Is this correct?

539B60023 VISN 10: VA Healthcare System of Ohio 539 CINCINNATI, OH XR US Trade in- In the Requirement overview it states 2x as the requirement, but in the tech specs qty is shows 3. Can the requirement be clarified as the quantity required?

589B63008 VISN 15: VA Heartland Network 589 COLUMBIA, MO XR PORT RAD 1d) Please edit generator mAs range to 0.1 to 320 to maximize competition 1i) Please edit to 200cm to maximize competition

w) Please edit maximum system weight to 1,250 lbs to maximize competition

688B61000VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CTWhich cardiac software package would you prefer - Cedars, Invia or Emory?
688B61000VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CTThe technical specifications reference a dual-detector, variable-angle, dual-head configuration. Can the NAC confirm whether alternative detector architectures — such as a fixed 360-degree solid-state CZT SPECT system — are considered acceptable if they meet or exceed the clinical performance and diagnostic intent of the solicitation?
688B61000VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CTThe specifications list minimum quantities of interchangeable collimators (LEHR, MEGP, HEGP, pinhole) as well as automatic and semi-automatic collimator changers. Are these requirements mandatory, or will the VA consider systems that utilize an integrated collimation design inherent to the detector architecture rather than removable collimators?
688B61000VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CTSeveral sections explicitly reference a dual-head configuration.Is this language intended to prescribe a specific detector geometry, or is it intended to describe minimum clinical capability that could also be met by a full-ring CZT system without mechanically independent detector heads?
688B61000VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CTCertain performance parameters (e.g., sensitivity reported in cpm/µCi and detector crystal thickness in inches) appear aligned with traditional NaI-based Anger cameras. Will the NAC accept alternative performance metrics appropriate to CZT-based systems, provided equivalent or superior clinical performance can be demonstrated?
688B61000VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CTShould the technical requirements be interpreted as prescriptive (requiring a specific hardware configuration), or functional (allowing alternative technologies that meet the intended diagnostic workflows and outcomes)?
688B61000VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CTWas the specification developed around a specific existing system or replacement baseline, and if so, is the intent to allow technologically advanced alternatives that differ in detector design but exceed performance expectations?
688B61000VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CTThe specs state 40-200keV, which isotopes are you looking to be able to image routinely on the system?
688B61000VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CTWhat is the clinical justification for a 128-slice CT? Would a 64-slice CT be acceptable?
688B61000VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CTWhat clinical needs are you looking to meet with the advanced nuclear oncology software?
688B61000VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CTIs the system going to be used for CTA acquisitions or is the requirement just to provide fusion software for nuclear and CTA data?
688B61000VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CTAre room dimensions and drawings available?
688B61000VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CTSince 2 systems are being purchased for the Washington DC VA, can we quote a server on one system that will support the required software components of both systems?
688B61000VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CTWhat is the current workflow for CT dose tracking with Bayer Radimetrics?
688B61000VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CTIs there a dedicated room provided for th installation of the UPS? If so, please include those room dimensions and drawings.
688B61001VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CTWhich cardiac software package would you prefer - Cedars, Invia or Emory?
688B61001VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CTThe technical specifications reference a dual-detector, variable-angle, dual-head configuration. Can the NAC confirm whether alternative detector architectures — such as a fixed 360-degree solid-state CZT SPECT system — are considered acceptable if they meet or exceed the clinical performance and diagnostic intent of the solicitation?
688B61001VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CTThe specifications list minimum quantities of interchangeable collimators (LEHR, MEGP, HEGP, pinhole) as well as automatic and semi-automatic collimator changers. Are these requirements mandatory, or will the VA consider systems that utilize an integrated collimation design inherent to the detector architecture rather than removable collimators?
688B61001VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CTSeveral sections explicitly reference a dual-head configuration. Is this language intended to prescribe a specific detector geometry, or is it intended to describe minimum clinical capability that could also be met by a full-ring CZT system without mechanically independent detector heads?
688B61001VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CTCertain performance parameters (e.g., sensitivity reported in cpm/µCi and detector crystal thickness in inches) appear aligned with traditional NaI-based Anger cameras. Will the NAC accept alternative performance metrics appropriate to CZT-based systems, provided equivalent or superior clinical performance can be demonstrated?
688B61001VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CTShould the technical requirements be interpreted as prescriptive (requiring a specific hardware configuration), or functional (allowing alternative technologies that meet the intended diagnostic workflows and outcomes)?
688B61001VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CTWas the specification developed around a specific existing system or replacement baseline, and if so, is the intent to allow technologically advanced alternatives that differ in detector design but exceed performance expectations?
688B61001VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CTThe specs state 40-200keV, which isotopes are you looking to be able to image routinely on the system?
688B61001VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CTWhat is the clinical justification for a 128-slice CT? Would a 64-slice CT be acceptable?
688B61001VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CTWhat clinical needs are you looking to meet with the advanced nuclear oncology software?
688B61001VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CTIs the system going to be used for CTA acquisitions or is the requirement just to provide fusion software for nuclear and CTA data?
688B61001VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CTAre room dimensions and drawings available?
688B61001VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CTSince 2 systems are being purchased for the Washington DC VA, can we quote a server on one system that will support the required software components of both systems?
688B61001VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CTWhat is the current workflow for CT dose tracking with Bayer Radimetrics?
688B61001VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CTIs there a dedicated room provided for the installation of the UPS? If so, please include those room dimensions and drawings.
590B69006VISN 06: VA Mid-Atlantic Health Care Network590 HAMPTON, VAXR US2.c. Image Navigation software & Fusion Software – is this clinically necessary on both systems? If not clinically necessary, please move to added value.
590B69006VISN 06: VA Mid-Atlantic Health Care Network590 HAMPTON, VAXR US8 Is Fusion-targeted Biopsy System and all the features in this section required on both systems? If not clinically necessary, please move to added Value.
590B69007VISN 06: VA Mid-Atlantic Health Care Network590 HAMPTON, VAXR US2.c. Image Navigation software & Fusion Software – is this clinically necessary on both systems? If not clinically necessary, please move to added value.
590B69007VISN 06: VA Mid-Atlantic Health Care Network590 HAMPTON, VAXR US8 Is Fusion-targeted Biopsy System and all the features in this section required on both systems? If not clinically necessary, please move to added Value.
5086B6001VISN 07: VA Southeast Health Care Network508 DECATUR, GAXR USThe trade-in that was requested has already been used as a trade-in on a previous purchase (Philips CX50, Serial Number SG21405744). Can you let them know and ask if they have any other systems they would like to use as a trade-in?
626B64014VISN 09: VA Mid South Healthcare Network626 NASHVILLE, TNXR USSection B - 2. D (Image Fusion Software): Is this referencing Echo Nav - TEE Fluoro Fusion used in Cath Lab? If so, we need to quote the Epiq CVxi.
626B64014VISN 09: VA Mid South Healthcare Network626 NASHVILLE, TNXR USSection B - 2.C (Navigation Software): Is this referencing 3D Auto MV formally known as Mitral Valve Navigator? If so, the newest version is 3D Auto MV.
626B64014VISN 09: VA Mid South Healthcare Network626 NASHVILLE, TNXR USSection B - 3. C (Power): Do they want MicroFlow Imaging quoted?
512B61001VISN 05: VA Capitol Health Care Network512 BALTIMORE, MDXR USSection B - 7. A (Transducers): Is this asking for 3 transducers total, or 3 per machine?
539B60017VISN 10: VA Healthcare System of Ohio539 CINCINNATI, OHXR USThis site purchased some features/capabilities on a previous PO that includes additional features not outlined in this RFO. Do you want the following features quoted? 3D Auto LAA, 3D Auto CFQ, Contrast Card perfusion
593B60001VISN 21: VA Sierra Pacific Network593 LAS VEGAS, NVXR HYBRIDWould foot-end transfer capability with a C-arm that moves around the table and operators that can improve patient safety and workflow efficiency be considered?
593B60001VISN 21: VA Sierra Pacific Network593 LAS VEGAS, NVXR HYBRIDInstead of incurring the high construction costs, floor reinforcement costs and downtime for adjacent ancillary areas required for an angio CT, could the Philips Azurion FlexArm deliver comparable imaging without those disruptions?
593B60001VISN 21: VA Sierra Pacific Network593 LAS VEGAS, NVXR HYBRIDWill the plan of installing up to four CT units before this project ensure sufficient availability for interventional use without disrupting other CT exams and procedures?
593B60001VISN 21: VA Sierra Pacific Network593 LAS VEGAS, NVXR HYBRIDWould clinicians and clinical team prefer a ceiling mount fixed C-arm system, specifically the Philips Azurion FlexArm that moves unrestricted and create more floor space?
757B60010VISN 10: VA Healthcare System of Ohio757 COLUMBUS, OHXR USImage Fusion Software. Please confirm what procedures will be performed utilizing Fusion.

Do you want a biplane, triplane or both transducers?

Do you want Transrectal (TR) or Transperineal (TP)?

Do you want stabilized or freehand?

516B60004VISN 08: VA Sunshine Healthcare Network516 BAY PINES, FLNM BONE DENPlease provide the number of techs/operators that will need clinical applications training.
675B67011VISN 08: VA Sunshine Healthcare Network675 VIERA, FLXR MAMMO3b. Imaging type-3D: Is this high resolution imaging or standard resolutions?
675B67011VISN 08: VA Sunshine Healthcare Network675 VIERA, FLXR MAMMO3l. Computer-aided detection: Is this 2D CAD? 2D & 3D CAD? Or 3D CAD?
675B67011VISN 08: VA Sunshine Healthcare Network675 VIERA, FLXR MAMMO3d: Stereo/tomo guided biopsy: Will you need a biopsy positioning chair?
675B67011VISN 08: VA Sunshine Healthcare Network675 VIERA, FLXR MAMMO3d: Stereo/tomo guided biopsy: Will you need a vacuum assisted breast biopsy system such as ATEC? Or a breast biopsy system with imaging such as Brevera?
675B67011VISN 08: VA Sunshine Healthcare Network675 VIERA, FLXR MAMMODo you require an ACR phantom with case?
671B60026VISN 17: VA Heart of Texas Health Care Network671 SAN ANTONIO, TXXR RAD2.h. Respectfully requests change minimum tube height from floor to 16 inches from 12 inches for fair competition.
671B60013VISN 17: VA Heart of Texas Health Care Network671 SAN ANTONIO, TXXR US"Are the following requirements needed for this request?

Line 35: Three-dimensional (3D) – freehand Line 36: Navigation Software Line 37: Image Fusion Software Line 60: Panoramic mode Line 69: Shear wave and strain-based elastography Line 73: Multi-function foot pedal control (programmable preferred) Line 89: Mitral Valve Navigator Line 90: Cardiac 3D Quantification Line 100: Fusion-Targeted Biopsy System Line 101: Capable of accepting MRI (both 1.5T and 3.0T) and ultrasound images from other modalities as input and displaying these images on a screen Line 102: Prostate gland volume and edge boundaries computation capabilities Line 103: Tracking and recording of needle movement during biopsy in 3D coordinates in real-time Line 104: Availability of projected, future needle movement during biopsy in 3D coordinates Line 105: Ability to overlay previous biopsy images on top of real-time prostate images Line 106: 3D-generated model of prostate that can be exported to report, adjustable by additional non-imaging information, such as pathology-related data Line 107: Semi-robotic arm, physically attached to biopsy system, with at least 3 degrees of freedom used to stabilize needle and ultrasound probe movements Line 108: Standard planning templates for prostate biopsies

642B69012VISN 04: VA Stars & Stripes Healthcare Network642 PHILADELPHIA, PAXR USThis is listed under Philadelphia but Specs say Phoenix. Please clarify the correct station.
675B67003VISN 08: VA Sunshine Healthcare Network675 ORLANDO, FLXR USIs 3D needed?
675B67003VISN 08: VA Sunshine Healthcare Network675 ORLANDO, FLXR USRequest to please reduce monitor size to 21 inches
5086B6002VISN 07: VA Southeast Health Care Network508 DECATUR, GAXR USLine 67 - Should these transducers be (9) IC10-3 for special use GYN rather than L12-3?
5086B6002VISN 07: VA Southeast Health Care Network508 DECATUR, GAXR USLine 68 - Are these probes needed for vascular access/line placement? If so, the replacement transducer for the L25 x is the L19 - should we switch them or are they even needed?
516B60003VISN 08: VA Sunshine Healthcare Network516 BAY PINES, FLNM BONE DEN1) Can we quote bill-to and ship-to of "Lee County VA Healthcare Center" at address "2489 Diplomat Pkwy E, Cape Coral" even though Matrix says site is "Lee County VA Community Based Out-reach Clinic?"

2) Can the VA purchase non-itegrated, subscription model TBS from MediMaps directly? 2j specifies Integrated TBS but the manufacturer of this 3rd party feature (MediMaps LLC) has ended production of the product as a permanent license integrated with GE's enCore DXA software. As of 2026 they commercialized the release of their Subscription Model (SaaS) and GE no longer has access to unlimited supplies of the permanent, integrated version on today's Gov't pricefile.

3) Max system dimensions 1k specify a compact table system - current system for replacement is not a compact - Please clarify if this is compact or not?

516B60004VISN 08: VA Sunshine Healthcare Network516 BAY PINES, FLNM BONE DEN1) Please disclose # techs needing training
558B69005VISN 06: VA Mid-Atlantic Health Care Network558 GREENVILLE, NCNM BONE DEN1) Please confirm exact location of GE DXA for replacement - was it purchased second-hand?

2) Spec 1h is vendor-limiting, please change to 18 inches.

619B62004 VISN 07: VA Southeast Health Care Network 619 MONTGOMERY, AL NM BONE DEN 1) Please confirm exact location of GE DXA for replacement - was it purchased second-hand?

2) Local contact says there are 2 units being purchased - is solicitation missing 1?

3) Spec 1m requests motorized table. This is a vendor-limiting spec. Please remove.

4) Spec 1h is vendor-limiting, please change to 18 inches.

589B63005 VISN 15: VA Heartland Network 589 COLUMBIA, MO XR MRI 1. g. Maximum system dimensions [in] Q: Please clarify system dimensions. Typical MR gantry dimensions are 100x100x100 inches. Mobile van dimension are 13’-6” H x 8’-6” W x 48’-0” L 3.f. UPS – maintains full functionality of the entire modality /system for a minimum of 120 minutes during a power outage Q: Mobile MR vans can’t accommodate a full system UPS. Please clarify if a console- only UPS is required. Typrical run time is 7 minutes.

5.o. Endorectal Coil Q: Please clarify if an endorectal coil is required or just high- quality prostate imaging.

658B69001 VISN 06: VA Mid-Atlantic Health Care Network 658 SALEM, VA XR HYBRID Please clarify the preferred equipment for this obligation. Line 2b indicates a requirement for a single‑plane system; however, Lines 2P, 2Q, 2R, and 2S list bi‑plane specifications. Please confirm which configuration is intended.

6D.) Degrees of Freedom Q: Please clarify the specific requirement being requested.

6F.)Minimum usable space [cm] Q: Please clarify what is being asked in this requirement, under the C‑arm specifications? What requirement is needed with this specification.

9.) Conference Room Requirements Q: What are the expectations for vendors regarding this requirement? Feed terminations are standard across all vendors: are you asking vendors to outfit the conference room with additional components?

10.) Video Sources Q: Is there a preferred video integrator or vendor you would like us to work with to support these requirements?

675B67011 VISN 08: VA Sunshine Healthcare Network 675 VIERA, FL XR MAMMO What vacuum assisted device is used for biopsy?

What version of Vista is being used?

Please increase weight to 925.

671B60026VISN 17: VA Heart of Texas Health Care Network671 SAN ANTONIO, TXXR RAD5a. Would you like Stitching at both the wallstand and and table?
589B63008VISN 15: VA Heartland Network589 COLUMBIA, MOXR PORT RAD2e and 2i and 3u. and 2v. And 2x. and 2y. Please move to value add
621B60001VISN 09: VA Mid South Healthcare Network621 MOUNTAIN HOME, TNXR PORT RAD1a. Please change to 30kw

3g. Ability to move from tube head - Please move to value add 3p. Positioning Hnadles - Please move to Value add 4c. Please move to value add 4j. Motion Detection - Please move to value add, this is a lock out spec from one single vendor 649B62004 VISN 22: VA Desert Pacific Healthcare Network 649 PRESCOTT, AZ XR PORT RAD Line 19 is a lock out to a specific vendor please update to generic spec and reduce spec to 40 KW generator 1b. System weight Change to 998 1e. Exposure time - Pleae change to 6.0 seconds 2d. Detecotr resolution - please change to 5 3e. Please move to value add

660B60001VISN 19: VA Rocky Mountain Network660 SALT LAKE CITY, UTXR PORT RAD3g and 3h. Please move to value add
688B61000VISN 05: VA Capitol Health Care Network688 WASHINGTON, DCNM SPECT CT1e – this energy range seems aligned to CZT, not NaI. We were under the impression that the clinical staff preferred one NaI and one CZT system. But both matrices are written identically and seem to suggest a traditional NaI SPECT/CT (aside from this energy range). Please clarify.

3y – Please remove or move to Value Adds to allow full and fair competition. Only one vendor can offer this.

3g – Please remove or move to Value Adds to allow full and fair competition. This is not typically performed in an NM department.

6i – Please remove or move to Value Adds to allow full and fair competition. Only one vendor can offer this.

688B61001 VISN 05: VA Capitol Health Care Network 688 WASHINGTON, DC NM SPECT CT 1e – this energy range seems aligned to CZT, not NaI. We were under the impression that the clinical staff preferred one NaI and one CZT system. But both matrices are written identically and seem to suggest a traditional NaI SPECT/CT (aside from this energy range). Please clarify.

3y – Please remove or move to Value Adds to allow full and fair competition. Only one vendor can offer this.

3g – Please remove or move to Value Adds to allow full and fair competition. This is not typically performed in an NM department.

6i – Please remove or move to Value Adds to allow full and fair competition. Only one vendor can offer this.

528B60173 VISN 02: VA Healthcare Network Upstate New York 528 BUFFALO, NY XR US Can you provide room dimensions to determine if a specific system will fit?

Can you please updated 17x17 detector weight to 8.4lbs

528B60230VISN 02: VA Healthcare Network Upstate New York528 BUFFALO, NYXR USCan you verify if 6.l. Cardiac 3D Quantification is required?
526B60006VISN 02: VA Healthcare Network Upstate New York526 BRONX, NYXR USRequest 1.h. Maximum equipment weight be increased to 265.
646B62003VISN 04: VA Stars & Stripes Healthcare Network646 PITTSBURGH, PAXR USRequest 1.m. Maximum equipment weight be increased from 240 lbs to 265 lbs.

Request items 8 Fusion a, c, and d be removed or moved to Added Value.

642B69007 VISN 04: VA Stars & Stripes Healthcare Network 642 PHILADELPHIA, PA XR US Request 1.m. Maximum equipment weight be increased to 140 lbs.

Request item 5.e. allow Physical buttons or Electronic Buttons.

642B69012 VISN 04: VA Stars & Stripes Healthcare Network 642 PHILADELPHIA, PA XR US Request item 1.k. Minimum Battery life be decreased to 20 min.

Request item 1.m. Maximum equipment weightbe increased from 90 lbs to 141 lbs.

Request 4.g. Locking Drawer be changed to Locking or non-Locking Drawer.

Under Section 6. Analysis Section - do you require any automated software for IUD Placement?

595B69005 VISN 04: VA Stars & Stripes Healthcare Network 595 LEBANON, PA XR US Can you verify if 5.j. Shear wave and strain-based elastography is required?

Can you verify the following 7. Transducers are required: 10EV3 and 9EC4 Transvaginal Transducers?

693B63002 VISN 04: VA Stars & Stripes Healthcare Network 693 WILKES-BARRE, PA XR US Request 1.a. and 1.b. be reduced to 14 inches.

Request 1.g. be increased to 141 lbs.

595B69009 VISN 04: VA Stars & Stripes Healthcare Network 595 LEBANON, PA XR US Can you verify if 5.e. Shear wave and strain-based elastography is required?

Can you verify 8.a. Capable of accepting MRI and Ultrasound Images and displaying them is required?

512B61001 VISN 05: VA Capitol Health Care Network 512 BALTIMORE, MD XR US Request 1.a. Minimum Screen Size be reduced to 14 inches.

Can you verify if all 3 systems will only be used for Vascular Access? If they will be uused for other procedures, please provide a list.

590B69006 VISN 06: VA Mid-Atlantic Health Care Network 590 HAMPTON, VA XR US Request 1.a. Please update the requirement to include “or equivalent” monitor.

Request 7.i. “DAX” is specific to one vendor. Please revise the requirement to include “or equivalent” transducer.

Request 8.f. Please move this requirement to the “Added Value” section to allow for fair competition.

Request 8.g. Please move this requirement to the “Added Value” section to allow for fair competition.

590B69007 VISN 06: VA Mid-Atlantic Health Care Network 590 HAMPTON, VA XR US Request 1.a. Please update the requirement to include “or equivalent” monitor.

Request 7.i. “DAX” is specific to one vendor. Please revise the requirement to include “or equivalent” transducer.

Request 8.f. Please move this requirement to the “Added Value” section to allow for fair competition.

Request 8.g. Please move this requirement to the “Added Value” section to allow for fair competition.

534B62015VISN 07: VA Southeast Health Care Network534 CHARLESTON, SCXR USRequest 1.a. Minimum Screen Size be reduced to 15.6 inches.
5086B6002VISN 07: VA Southeast Health Care Network508 DECATUR, GAXR USFor the Cardiology System: There is no cardiac probes are listed do you need them?

What type of scans will be done with this device?

Do you want a laptop or cart based system?

5086B6001 VISN 07: VA Southeast Health Care Network 508 DECATUR, GA XR US Does this system do 2D or 4D ICE?

Is this for EP or structural heart?

What procedures will you do with this device?

675B67003 VISN 08: VA Sunshine Healthcare Network 675 ORLANDO, FL XR US Request 1.j. Maximum equipment weight increased to 265.

Request 1.h. Minimum image storage decreased to 1 TB.

Can you verify if Navigation Software is required?

Can you verify if Imag Fusion Software - combining real-time Ultrasound Images with CT, MRI, or PET Scans - is required?

516B50008VISN 08: VA Sunshine Healthcare Network516 BAY PINES, FLXR USRequest 1.l. Maximum equipment weight increased to 265.
675B67010VISN 08: VA Sunshine Healthcare Network675 ORLANDO, FLXR USRequest item 1.a. Minimum screen size be reduced to 19 inches.

Can you verify if 2.b. Three-dimensional 3D is required?

Can 4.a. a keyboard on the display be required in lieu of the Physical keyboard?

Can you verify if 5.j. Shear wave and strain-based elastography is required?

626B64014VISN 09: VA Mid South Healthcare Network626 NASHVILLE, TNXR USRequest 1.k. Minimum battery life reduced to 30 minutes.
626B64007VISN 09: VA Mid South Healthcare Network626 NASHVILLE, TNXR USRequest 1.a. Minimum Screen Size be reduced to 15.6 inches.

Request 1.m. Maximum equipment weight be increased to 125 lbs.

Request 6.e. Please remove mitral valve navigator to make this vendor inclusive.

626B63000VISN 09: VA Mid South Healthcare Network626 MURFREESBORO, TNXR USRequest 1.a. Minimum screen size be reduced to 19 inches.
556B61009VISN 12: VA Great Lakes Health Care System556 NORTH CHICAGO, ILXR USRequest Offeror information be removed.

Request 1.a. Minimum Screen Size be reduced to 15.6 inches.

589B60001 VISN 15: VA Heartland Network 589 KANSAS CITY, MO XR US Request item 1.j. Minimum battery life be reduced to 30 min.

Can you verify the Trade-in Serial Numbers?

671B60013 VISN 17: VA Heart of Texas Health Care Network 671 SAN ANTONIO, TX XR US Request item 1.m. Maximum equipment weight be increased to 125 lbs.

Can you verify if 2.a. Three Dimensional (3D) will be required?

Can you verify if Navigation Software is required?

Can you verify if Imag Fusion Software - combining real-time Ultrasound Images with CT, MRI, or PET Scans - is required?

Can you verify if 5.j. Shear wave and strain-based elastography is required?

Can you verify if 6,k, and l. are required?

Can you verify if 8.a., c., d, f,, and g. are required?

663B63008 VISN 20: VA Northwest Network 663 SEATTLE, WA XR US Request item 1.j. Minimum battery life be reduced to 90 min.

Request item 1.m. Maximum equipment weight be increased to 190 lbs.

662B61005 VISN 21: VA Sierra Pacific Network 662 SAN FRANCISCO, CA XR US item 5.a. Physical Keyboard Please allow a Keyboard on the Touch screen in luei of a Physical Keyboard.

Item 8 Transducers - Can you verify only two Transducers are required as the Description under a and b is missing.

585B63001 VISN 12: VA Great Lakes Health Care System 585 IRON MOUNTAIN, MI XR RAD Can you provide room dimensions to determine if a specific system will fit?

Can you please updated 17x17 detector weight to 8.4lbs

589B63006VISN 15: VA Heartland Network589 COLUMBIA, MOXR US2.c Is navigation clinically necessary for the CBOC? This feature requires staff experience in fusion and navigation, along with the capabilities from MRI/CT. Can this be moved to value add or removed? This feature requires staff experience in fusion and navigation, along with the capabilities from MRI/CT . Can this be moved to value add or removed?
589B63006VISN 15: VA Heartland Network589 COLUMBIA, MOXR US2.d. Is image fusion clinically necessary for the CBOC?
589B63006VISN 15: VA Heartland Network589 COLUMBIA, MOXR US5. n. Is a phantom clinically necessary? These should already be available in Biomed. Can this be moved to value add or removed?
589B63008VISN 15: VA Heartland Network589 COLUMBIA, MOXR PORT RAD2. e. Can the 14x17 detector pixels be adjusted from 100 microns to 140 microns, as this is the ideal pixel rate for chest X-rays?
528B60173VISN 02: VA Healthcare Network Upstate New York528 BUFFALO, NYXR USG. Please provide description of TradeIn system EE#262182 mentioned in Description
528B60173VISN 02: VA Healthcare Network Upstate New York528 BUFFALO, NYXR USB.6. Please verify ALL analysis packages are needed for this Women's Health system
528B60173VISN 02: VA Healthcare Network Upstate New York528 BUFFALO, NYXR US7. Do you want any volumetric transducers?
642B69012VISN 04: VA Stars & Stripes Healthcare Network642 PHILADELPHIA, PAXR USB.1. At 90 lbs, you're a looking a compact or laptop based ultrasound on a cart. With this configuration, most vendors will not have a main screen or touch-based screen. Do you require a main screen and a separate active screen? If so, you would need to open the weight limit to at least 130 lbs.
642B69012VISN 04: VA Stars & Stripes Healthcare Network642 PHILADELPHIA, PAXR USB.1.m. Please verify maximum weight; can this be opened up to 130 lbs?
642B69012VISN 04: VA Stars & Stripes Healthcare Network642 PHILADELPHIA, PAXR USB.4.d. You ask for a printer; does that mean you're looking for a cart to go with the ultrasound system?
526B60006VISN 02: VA Healthcare Network Upstate New York526 BRONX, NYXR US1.h. Can the Max equipment weight be raised to 245 lbs to increase competition (currently at 240 lbs)?
528B60230VISN 02: VA Healthcare Network Upstate New York528 BUFFALO, NYXR USA. Please verify the Qty of systems desired: Schedule lists Qty 2 and Tech Spec lists Qty 1.
528B60230VISN 02: VA Healthcare Network Upstate New York528 BUFFALO, NYXR USG. Please provide Make/Model and Install Year for 3 trade-in systems identified in Section A: EE# 235937, 246780, and 249222
528B60230VISN 02: VA Healthcare Network Upstate New York528 BUFFALO, NYXR US2.m and 2.n Please move these items to Value Add as they look to be vendor-specific
595B69005VISN 04: VA Stars & Stripes Healthcare Network595 LEBANON, PAXR US7.b. Please provide frequency range for DAX - this looks to be vendor-specific
646B62003VISN 04: VA Stars & Stripes Healthcare Network646 PITTSBURGH, PAXR USB.1.m. Can the Max equipment weight be raised to 245 lbs to increase competition (currently at 240 lbs)?
646B62003VISN 04: VA Stars & Stripes Healthcare Network646 PITTSBURGH, PAXR US8. Please verify Fusion is needed for Vascular systems. If so, is it required for all 5 systems?
5086B6002VISN 07: VA Southeast Health Care Network508 DECATUR, GAXR US1h). Please change minimum battery life to 60min to allow for full and fair competition.

1j). Please change maximum system weight to 200lbs to allow for full and fair competition.

516B50008 VISN 08: VA Sunshine Healthcare Network 516 BAY PINES, FL XR US 2l). Please change maximum equipment weight to 250lbs to allow for full and fait competition.

3b). Please specify functional need for or remove the 4D – freehand requirement as this not typically a clinical requirement.

3c). Please confirm the need for navigation software on ultrasound system.

3q). Please confirm need for or remove 4D volume systolic and diastolic auto requirement.

3r). Please confirm need for or remove 2D systolic and diastolic auto requirement.

534B62015 VISN 07: VA Southeast Health Care Network 534 CHARLESTON, SC XR US 1a). Please change minimum screen size to 20 inches to allow for full competition.

1i). Please change minimum battery life to 60min to allow for full competition.

621B60001 VISN 09: VA Mid South Healthcare Network 621 MOUNTAIN HOME, TN XR PORT RAD 1a). Please change minimum generator power to greater than or equal to 40kW to allow for full competition. Only one vendor meets the current requirement.

1m). Please change maximum pixel size to less than or equal to 140 microns to allow for full competition. Only one vendor meets the current requirement.

2f). Please change maximum wireless detector pixel size to less…