This document is a set of plans and drawings related to a state and local contract opportunity issued by the Oregon Department of Transportation (ODOT) for the ESB - Lenel Card Reader Access - Estacada Dist 2C HQ and Sandy Maintenance Station project. The project requires an ESB Certified contractor to add Lenel access control to an existing motorized cantilever gate and multiple building entry points. The work includes running low voltage wiring from the gate to a card reader enclosure and multiple door entries, as well as adding additional Lenel keypads and readers as specified in the plans. The project covers locations in Clackamas County, Eugene City, and San Marino CDP.
The plans provide details on the existing conditions, including a 4-inch conduit sleeve under the drive entrance, new 4-inch sleeve pipes across the landscape area, and a 1-inch underground data conduit run from the office to the gate motor and gate pedestal. The plans also indicate the locations of existing Lenel panels, doors scheduled for new card readers, and the data/communication room. Pricing terms, set asides, incumbents, funding requirements, and other salient information are not included in the provided documents.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
E (2) TWO DOORS FOR ACCESS
READERS THIS BUILDING
NOTE TO BIDDERS - THIS 05/09/22 DRAWING IS FOR REFERENCE ONLY
TO SHOW THE BUILDING AND GATE PEDESTAL SCHEDULED FOR WORK
E GATE PEDESTAL
LOCATION
EXIST 4" CONDUIT
SLEEVE UNDER
DRIVE ENTRANCE
2 NEW 4" SLEEVE PIPES
ACROSS THE LANDSCAPE
AREA.
NEW 1" UNDERGROUND
DATA CONDUIT RUN FROM
OFFICE TO GATE MOTOR &
GATE MOTOR TO PEDESTAL;
RUN 1" THROUGH 4" SLEEVE
EXIST GATE
MOTOR
NOTE TO BIDDERS - THIS 08/31/22 DRAWING IS FOR REFERENCE
ONLY TO SHOW THE BUILDING AND GATE PEDESTAL SCHEDULED
FOR WORK
E CAMERA - REMOVE. INSTALL NEW CARD
READER THROUGH EXISITING HOLE.
RED CIRCLED AREAS ARE E DOORS
SCHEDULED FOR NEW CARDREADERS,
TYPICAL OF TWO (2) THIS BUILDING.
EXTERIOR AND INTERIOR DOORS AND
FRAMES ARE METAL.
LENEL PANEL SHALL BE LOCATED IN
THIS AREA. CONTRACTOR CAN
MOUNT TO EXISTING PANEL BOARD
REMOVE EXISTING
DOOR RELEASE
BUTTON.
MAINTENANCE BUILDING
- TWO (2) DOORS
NOTE TO BIDDERS - THIS 1996 DRAWING IS
FOR REFERENCE ONLY TO SHOW THE
BUILDING SCHEDULED FOR ACCESS WORK
NOTE TO BIDDERS - THIS 1996 DRAWING
IS FOR REFERENCE ONLY TO SHOW
LOCATION OF DOORS AND DATA/
COMMUNICATION ROOM
RED CIRCLED DOORS ARE E
DOORS SCHEDULED FOR NEW
CARDREADERS, TYPICAL OF TWO
(2) THIS BUILDING.
EXTERIOR DOORS AND FRAMES
ARE METAL
DATA/ COMMUNICATION ROOM
IS AT MEZZANINE LEVEL OVER
THE WOMEN'S ROOM.
EXISTING LENEL PANEL IS
LOCATED AT DATA/
COMMUNICATION ROOM
STAIR LOCATION TO DATA/
COMMUNICATION ROOM
S T
A
IR
S E THROUGH WALL
CONDUIT TO SHOP FOR
CABLING
ELECTRICAL
PANELS
LOCATION
NOTE TO BIDDERS - THIS 1996 DRAWING