This is an electrical power plan document for an Athletic Team Room project at Mattawan Consolidated Schools in Mattawan, Michigan, prepared by Tower Pinkster architectural and engineering firm. The project involves comprehensive electrical infrastructure installation including power distribution, lighting, HVAC systems, security systems, and technology connectivity. The plan specifies the installation of panelboard P1 with a 400-ampere main breaker fed from transformer TX-P1, operating at 208/120 volts, three-phase, four-wire service. The document details circuit requirements for 84 individual breakers including receptacles, hand dryers, HVAC equipment, lighting systems, and specialized systems such as door security devices, cameras, and technology equipment. The total connected load is approximately 43,566 VA with an estimated demand of 42,536 VA and total amperage of 154 amperes at the main panel. The plan includes grounding specifications with multiple ground rods and connections to building structural steel, cable conduit routing requirements, and device mounting locations throughout the facility.
The electrical specifications require the contractor to perform all cutting, patching, and final connections to owner-provided equipment while maintaining fire ratings at all penetrations. The document specifies GFI protection on designated circuits, conduit sizing requirements ranging from 1/2-inch to 4-inch, and coordination requirements with furniture shop drawings and technology plans. Security system conduit work must be consolidated by type and routed to the central IT rack location with proper labeling. All exterior conduit must be buried below grade using trenching and directional boring methods to eliminate exposed exterior wiring. The plan includes load classifications for hand dryers (3,600 VA), technology systems (720 VA), HVAC equipment (various circuits), lighting (3,396 VA), and general receptacle loads (12,060 VA), with specific demand factors applied to calculate actual electrical requirements.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 1 - ECEC_Team Room Phone Specifications.pdf | ||
| Updated Phone Bid Due Date & Opening.pdf | ||
| District Closure_Phone Bid Postponement_20200325.docx | DOCX document | |
| District Closure_Bid Submitting Information_20200318.docx | DOCX document | |
| 2 - ECEC Phone Locations_B.jpg | JPG image |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
M
HD HD
HD HD
JJ
J
J
JJ
J J J
PRJ
A/B/...
PRJ
A/B/...
M M
T
CR
CR
C R
C R
CR
CR
CR
CR
DC
D C
D C
DC
DC
D C
D C
D C
D C
E S
ES
E S
ES
E S
E S
E S
E
SDC
DC
DC
M M M
S S
S S
M
T.O.W.
110' - 0"
T.O.W.
110' - 0"
T.O.WALL
110' - 8"
T.O.WALL
110' - 8"
2" CONDUIT TO
DATA RACK
2" C.
COORDINATE DEVICE
LOCATIONS WITH
LAPTOP STAND.
MOUNT FLUSH INSIDE
ENCLOSURE.
2-GANG
DATA
FIRST FLOOR
100' - 0"
2" C.
1" C.
SPEAKER
PROVIDE SINGLE
GANG BOX.
TYPICAL
1" C.
18" X 18" X 6" NEMA 3R
HOFFMAN JUNCTION BOX
WITH HINGED COVER
CRESTRON AV
TOUCH SCREEN
3-GANG BOX
120V
/5
/3
P1
PANEL
SPD
8320V
480/277V
TX-PRI
GROUND BUS
10' SPACING (TYP)
WATER MAIN
#3/0 Cu GND (TYP)
10'-0"
GROUND ROD
CONTRACTOR TO TERMINATE
CONDUCTORS AT TRANSFORMER, UTILITY
METER TO BE INSTALLED ON
TRANSFORMER. COORDINATE WITH
UTILITY.
M
TO UTILITY POLE
145A
4 #600, 4" PVC
3 #1/0 15 kV 133%
PRIMARY W/CONCENTRIC
NEUTRAL, 4" PVC
24A
EXISTING
PANEL
P2
4 #1/0, 2" PVC
#3/0 Cu GND (TYP)
10'-0"
GROUND ROD PROVIDE NEW GROUND
ROD AND NEW BUILDING
GROUND BAR.
GROUND BUS
SERVICE
TRANSFORMER
GND.
TO BUILDING
STEEL
CONNECTIONS
TO GROUND MAT
NOTES:
1. ALL GROUNDING CONDUCTOR CONNECTIONS TO MAIN BUILDING GROUND BUS SHALL
BE EXOTHERMIC WELDED.
2. FOR QUANTITIES AND LOCATIONS AT STEEL COLUMNS, SEE FLOOR PLANS. FOR EACH
COLUMN CONNECTION, PROVIDE 1"C, 1#3/0 GROUND WIRE TO MAIN BUILDING BUS. (TYP.
FOR EVERY OTHER COLUMN @ PERIMETER)
3. ALL NEW TRANSFORMERS SHALL HAVE SEPARATE GROUND ROUTED BACK TO THE MAIN
SERVICE PANEL, BONDING TO NEARBY STEEL WILL NOT BE ACCEPTABLE.
TO MAIN
WATER PIPE
#3/0 GND. 1" C
TYPICAL
ELECTRICAL GROUND BUS
TO TRANSFORMER
GNDS.
IT GROUND BUS
120 VOLT
N
L
STARTER
MANUAL MOTOR
DISCONNECT
FAN BY DIV. 23
SWITCH W/
CONTACTS BY DIV. 23
OR TEMP. CONTROL
REVERSE ACT. STAT.
G FAN
#12
120V, 1Ø
208V, 3Ø
#10
FURNACE
CONDENSING
UNIT
MANUAL MOTOR
STARTER SWITCH
W/ LOCKOUT
6- #18
3- #18
T
30/3 NFDS
NEMA 3R
DOOR
CONTACTS
TO SECURITY CONTROL PANEL
CEILING
1/2" C
1" C
1" CONDUIT BETWEEN
WHERE LESS THAN 60"
REFER TO SECURITY DOOR
SCHEDULE FOR DEVICE
REQUIREMENTS AT EACH DOOR
3/4" FLEX CONDUIT TO BE RUN INSIDE
DOOR FRAMES TO STRIKEPLATE
3/4" CONDUIT
ELECTRIC STRIKE
RECESSED IN FRAME
CARD READER SINGLE GANG BOX
POWER SUPPLIES TO BE CENTRALLY LOCATED NEXT TO NEAREST
ACCESS CONTROL PANEL UNLESS OTHERWISE INDICATED.
REFER TO TECHNOLOGY PLAN FOR EXACT LOCATIONS.
SEAL ALL CONDUITS THROUGH CEILING
CORNER BRACKET
AND FASTENERS
EXTERIOR PENETRATION SHALL
BE CONCEALED BY MOUNTING
BRACKET. RUN 1" CONDUIT
BACK TO IT RACK.
3/4" LIQUID TIGHT CONDUIT
SHALL BE RUN FROM INTERIOR
MOUNTED SG BACKBOX
THROUGH PENETRATION TO
CAMERA MOUNTING BRACKET.
CAMERA MOUNTING
BRACKET
REFER TO FLOOR PLAN OR
CAMERA SCHEDULE FOR
ELEVATION REQUIREMENTS.
CEILING
EXTERIOR CORNER MOUNT CAMERAS
P1
BUILDING
GROUND BAR
TX-P1
10' GROUND
ROD (TYPICAL)
WH-1
F-3
F-2
F-1
ACCU-1 ACCU-2 ACCU-3
STORAGE
HOME LOCKER
ROOM
VISITOR
LOCKER ROOM
TRAINING
STORAGE
TLT
OFFICIALS
WOMENS
RESTROOMS
J.C./MECH.
MENS
RESTROOMS
CONCESSIONS
ELEC/IT
P1- 6
GFI
P1- 7
GFI
P1- 8
GFIP1- 9
GFI
P1- 10
GFI
P1- 11
GFI
P1- 12
GFI
P1- 13
GFI
P1- 14
GFIP1- 15 P1- 16
P1- 4
P1- 3 P1- 2
P1- 5
P1- 5
P1- 5
P1- 5
P1- 33
P1- 17
P1- 18
GFI
P1- 18
GFI
2 2
2 2
P1- 19
GFI
P1- 19
GFI
P1- 19
GFI
P1- 19
GFI
P1- 19
GFI
P1- 21
P1- 20
P1- 19
P1- 22 P1- 23
P1- 26
GFI
P1- 25P1- 24
P1- 27
GFI
P1- 27 P1- 27
P1- 27
P1- 27 P1- 27
P1- 31
P1- 60 P1- 31
P1- 60
P1- 31
P1- 33
P1- 33
P1- 62P1- 62
P1- 37
GFI
P1- 30
GFI
P1- 30
GFI
P1- 32
GFI
P1- 32
GFI
P1- 32
GFI
P1- 35
P1- 34
WP
P1- 34
WP
P1- 34
WP
P1- 29
WP
P1- 29
WP
P1- 28
WP
P1- 28
WP
P1- 47,49P1- 43,45P1- 39,41
E 101
W
W
P1- 26
GFI
P1- 48P1- 44 P1- 46
P1- 7
GFI
P1- 8
GFI
P1- 50
GFI
P1- 1
GFIP1- 14
GFI
P1- 52
GFI
P1- 51
GFI
#3/0 GND. WIRE
(TYPICAL)
IT GROUND BAR
4'x8' FIRE RATED
PLYWOOD
WALL MOUNTED
PHONE
WALL MOUNTED
PHONE
WALL MOUNTED
PHONE
UTILITY PAD
P1- 31
GFI
P1- 33
GFI
19' - 0"
W
W
60/2 NEMA 3R NFD
TYPICAL OF 3
#6 WIRE, 1" C.
P1- 56
GFI
WALL MOUNTED
PHONE
CP-1
P1- 53
EF-1 EF-2 EF-3P1- 46
WP
P1- 28
FEED FROM LOAD
SIDE OF GFI OUTLET
E a s t K a la m a z o o A v e n u e S u it e
K a la m a z o o M ic h ig a n
-5
.3
.6
P H
O N
E
.3
.6
F A
X
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
E a s t
F u lt o n S tr e e t, S u it e
G ra n d R a p id s M ic h ig a n
.4
.9
P H
O N
E
.4
.5
F A
X
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
P O
W E
R P
L A
N
-1
.4
E
M A
Y
A T
H L E
T
IC
T E
A M
R O
O M
M a tt a w a n M
I
M A
T T
A W
A N
C O
N S
O L
ID
A T
E D
S C
H O
O L S
GENERAL ELECTRICAL NOTES
ELECTRICAL KEYED NOTES
1 ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING
AND PATCHING REQUIRED FOR NEW WORK OR WHERE DEVICES ARE
REMOVED AND NOT REPLACED.
2 PROVIDE FINAL CONNECTION TO ALL OWNER/CONTRACTOR PROVIDED
EQUIPMENT. COORDINATE RECEPTACLE SIZES AND TYPE WITH
EQUIPMENT, ADJUST CIRCUIT SIZE AS REQUIRED.
3 PATCH ALL PENETRATIONS AS REQUIRED TO MAINTAIN FIRE RATING.
4 REFER TO INTERIOR ELEVATIONS, SECTIONS, ARCHITECTURAL
ELEVATIONS AND RELATED DRAWINGS FOR EXACT DEVICE LOCATIONS
AND MOUNTING HEIGHTS. WHERE DEVICES ARE MOUNTED UNDER OR
ABOVE TACK BOARDS, DOORS, WINDOWS, OR ANY PIECE OF
EQUIPMENT, THE ELECTRICAL DEVICE SHALL BE CENTERED AS SHOWN.
COORDINATE LOCATION OF FURNITURE CONNECTIONS AND/OR
RECEPTACLES AND DATA RACEWAYS WITH APPROVED FURNITURE
SHOP DRAWINGS, FINAL CONNECTIONS TO FURNITURE BY ELECTRICAL
CONTRACTOR.
5 SEAL ALL CONDUITS PENETRATING ATTIC SPACE TO ENSURE NO AIR
TRANSFER.
6 HOME RUN ALL DATA CONDUITS BACK TO IT RACK. LABEL EACH
CONDUIT AND DEVICE. CONSOLIDATE ALL SECURITY CONDUITS BY
TYPE, I.E. CAMERA CONDUITS AND DOOR SECURITY CONDUITS.
7 ALL CONDUITS SHALL ENTER/EXIT THE BUILDING BELOW GRADE.
PROVIDE TRENCHING AND DIRECTIONAL BORING AS REQUIRED. CUT
AND PATCH AS REQUIRED. NO EXPOSED CONDUIT SHALL BE ALLOWED
ON EXTERIOR OF BUILDING.
8 PROVIDE 4" HOUSEKEEPING PADS FOR TRANSFORMER. PROVIDE
FLEXIBLE CONNECTION TO TRANSFORMERS AND SIMILAR EQUIPMENT
PER SPECIFICATIONS.
1 PROVIDE 1" CONDUIT FROM DOOR CONTACT BACK TO IT RACK.
2 PROVIDE ROUGH IN FOR AUTOMATIC FLUSH VALVE. COORDINATE
LOCATION WITH SHOP DRAWING. THERE SHALL BE NO EXPOSED
CONDUIT OR JUNCTION BOX. PROVIDE ALL REQUIRED LOW VOLTAGE
WIRING BETWEEN VALVE AND TRANSFORMER.
3 FEED FROM GFI TYPE CIRCUIT BREAKER. LABEL DEVICE ON COVER
PLATE.
4 PROVIDE 2-GANG FLUSH MOUNTED BACKBOX AND 1" CONDUIT BACK
TO DATA RACK FOR WIRELESS ACCESS POINT.
5 PROVIDE WEATHER PROOF ENCLOSURE IN ATTIC SPACE WITH 1"
CONDUIT HOME RUN BACK TO IT RACK. REFER TO DETAIL
6 PROVIDE 1" CONDUIT TO IT RACK FOR CAMERA.
7 PROVIDE WALL MOUNTED LOCKING DESK. GLOBAL INDUSTRIAL
#WB249997. PROVIDE POWER AND DATA DEVICE CENTER INSIDE.
DEVICES SHALL BE FLUSH MONTED IN WALL AND FLUSH INSIDE THE
CABINET. MODIFY BACK OF CABINET AS REQUIRED FOR JUNCTION
BOXES.
1/4" = 1'-0"E 101
2 TYPICAL LOCKER ROOM ELEVATIONNOTES:
HAND DRYER - 3600 VA 100.00% 3600 VA
TECHNOLOGY - 720 VA 100.00% 720 VA
RECEPTACLE - 12060 VA 91.46% 11030 VA TOTAL ESTIMATED DEMAND... 118 A
POWER - 23222 VA 100.00% 23222 VA TOTAL CONNECTED LOAD (A): 121 A
Other 568 VA 100.00% 568 VA TOTAL ESTIMATED DEMAND: 42536 VA
LIGHTING - 3396 VA 100.00% 3396 VA TOTAL CONNECTED LOAD: 43566 VA
HVAC - 0 VA 0.00% 0 VA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS
TOTAL AMPS: 154 A 102 A 109 A
TOTAL LOAD: 18419 VA 12194 VA 12953 VA
83 SPARE 20 1 0 0 1 20 SPARE 84
81 SPARE 20 1 0 0 1 20 SPARE 82
79 SPARE 20 1 0 0 1 20 SPARE 80
77 SPARE 20 1 0 0 1 20 SPARE 78
75 SPARE 20 1 0 0 1 20 SPARE 76
73 SPARE 20 1 0 0 1 20 SPARE 74
71 SPARE 20 1 0 0 1 20 SPARE 72
69 SPARE 20 1 0 0 1 20 SPARE 70
67 SPARE 20 1 0 0 1 20 SPARE 68
65 SPARE 20 1 0 0 1 20 SPARE 66
63 -- -- -- 0 0 1 20 SPARE 64
61 -- -- -- 0 540 1 20 62
59 PUMP HOUSE PANEL P2 100 3 0 540 1 20 60
57 SPARE 20 1 0 0 1 20 SPARE 58
55 180 1 20 RECEPTACLE - 56
53 HVAC - 20 1 0 436 1 20 Other 54
51 RECEPTACLE - 20 1 180 180 1 20 RECEPTACLE - 52
49 -- -- -- 3037 180 1 20 RECEPTACLE - 50
47 POWER - ACCU-3 20 2 3037 0 1 20 HVAC - EF-3 48
45 -- -- -- 3037 180 1 20 HVAC - EF-2 46
43 POWER - ACCU-2 20 2 3037 0 1 20 HVAC - EF-1 44
41 -- -- -- 3037 538 1 20 LIGHTING - 42
39 POWER - ACCU-1 20 2 3037 720 1 20 LIGHTING - 40
37 RECEPTACLE - 20 1 180 1225 1 20 LIGHTING - 38
35 RECEPTACLE - 20 1 180 1045 1 20 LIGHTING - 36
33 RECEPTACLE - 20 1 720 540 1 20 RECEPTACLE - 34
31 RECEPTACLE - 20 1 720 540 1 20 RECEPTACLE - 32
29 RECEPTACLE - 20 1 360 360 1 20 RECEPTACLE - 30
27 RECEPTACLE - 20 1 1080 540 1 20 RECEPTACLE - 28
25 HAND DRYER - 20 1 900 360 1 20 RECEPTACLE - 26
23 HAND DRYER - 20 1 900 900 1 20 HAND DRYER - 24
21 HVAC - F-2 20 1 0 900 1 20 HAND DRYER - 22
19 RECEPTACLE - 20 1 5900 0 1 20 HVAC - F-1 20
17 HVAC - F-3 20 1 0 360 1 20 RECEPTACLE - 18
15 RECEPTACLE - 20 1 180 180 1 20 RECEPTACLE - 16
13 RECEPTACLE - 20 1 180 360 1 20 RECEPTACLE - 14
11 RECEPTACLE - 20 1 180 180 1 20 RECEPTACLE - 12
9 RECEPTACLE - 20 1 180 180 1 20 RECEPTACLE - 10
7 RECEPTACLE - 20 1 360 360 1 20 RECEPTACLE - 8
5 RECEPTACLE - 20 1 720 180 1 20 RECEPTACLE - 6
3 RECEPTACLE - 20 1 180 180 1 20 RECEPTACLE - 4
1 RECEPTACLE - 20 1 180 180 1 20 RECEPTACLE - 2
CIRCUIT DESCRIPTION
TRIP
(A) POLES A B C POLES
TRIP
(A) CIRCUIT DESCRIPTION
ADDED ACCESSORIES: SPD I.C. RATING: 35,000
LOCATION: FIRST FLOOR AMPS: 400 A MB , ULSE RATED FED FROM: TX-P1
PANEL: P1 MOUNTING: SURFACE VOLTAGE: 208/120V, 3PH, 4W
PANELBOARD "P1" LOAD SCHEDULE
SCALE: NONE
ONE LINE
SCALE: NONE
BUILDING GROUND DETAIL
SCALE: NONE
EXHAUST FAN CONTROL
SCALE: NONE
FURNACE/CONDENSING UNIT
SCALE: NONE
TYPICAL SECURITY DOOR DETAIL
SCALE: NONE
EXTERIOR CORNER MOUNT CAMERA
1/4" = 1'-0"
POWER PLAN
ISSUED FOR DATE
Tony Nuismer
WP
Tony Nuismer
WP
Tony Nuismer
WP
Tony Nuismer
WP
Tony Nuismer Wall Phone (WP) - 4
| Sheets |
| ES 101 - ELECTRICAL SITE PLAN |
| E 101 - POWER PLAN |
| E 201 - LIGHTING PLAN |
File details come from the government source that posted it. Updated .