This file package includes plans for a conference room remodel project for the Deputy Regional Forester office. The related federal contract opportunity is solicitation number 1240LU24Q0005 from the Department of Agriculture Forest Service seeking conference room remodel services. The solicitation requests proposals to remodel the existing conference room at the DRF office, as detailed in the 16MB plan set file. Interested contractors should respond with pricing to complete demolition, construction, and furnishings installation per the specifications by July 15th for award and project commencement in August. The set-aside category and any incumbent were not provided.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
@ at A.B. anchor bolt A/C air conditioning ACC PNL access panel ACOUST acoustical ACT acoustical ceiling tile AD area drain ADJ adjacent AFF above finished floor AIB air infiltration barrier ALT alternate ALUM aluminum ANOD anodized APPROX approximate ARCH architect AUTO automatic BBD bulletin board BD board BITUM bituminuous BL building line BLDG building BLK block BLKG blocking BM beam/bench mark BO by owner B.O. bottom of BOT bottom BRG bearing BSBD baseboard BTWN between B.O.W. bottom of wall BU built up CAB cabinet CAP capacity CB catch basin CL centerline C.C. center to center CDX exterior grade plywood CG corner guard CH channel CI cast iron/cubic inches CJ control joint CLG ceiling C.L.L. contract limit line CL center line
ABBREVIATIONS:
GA gauge GB grab bar GALV galvanized G.C. general contractor GEN general GFRG glass fiber reinforced gypsum GI galvanized iron GL glass GLU LAM or G.L.B. glue laminated beam GRD grade/grid GWB gypsum wall board GYP gypsum HB hose bib HC hollow core/handicapped HD BD Hard board HDR header HOR horizontal HR hour HT height HTG heating HVAC heating, ventilation, air conditioning HW hot water
PART.BD.particle board PART’N partition PC precast concrete PFM prefinished metal PL plate P.LAM plastic laminate PLWD plywood PNL panel PR pair PSL parallel strand lumber PT point PTD paper towel dispenser
T tread/thermostat TB towel bar TEL telephone TEMP temperature T&G tongue and groove THK thick THRU through TJI Truss Joist Incorporated
CLR clear CMU concrete masonry unit CO clean out COL column CONC concrete COND condition CONF conference CONN connection CONST construction CTRD centered CONT continuous CONTR contractor CORR corridor CPT carpet CT ceramic tile CUH cabinet unit heater CW curtain wall system CY cubic yard DBL double DEPT department DF drinking fountain DIA diameter DIAG diagonal DIM dimension DISP dispenser DN down DR door DWR drawer DS downspout DTL detail DWG drawing E east EA each EIFS exterior insulation finish system E.J. expansion joint EL/ELEV elevation - height/elevator ELEC electrical ENCL enclosure EO electrical outlet EP electrical panel EQ equal EQUIP equipment EWA/EW exterior wall assembly EWC electrical water cooler EWH electrical water heater (E)/EXISTexisting EXH exhaust EXP expansion EXT exterior
IN inch INCL included INFO information INSUL insulation INT interior IWA/IW interior wall assembly
T.O. top of T.O.B. top of beam T.O.C. top of concrete T.O.P. top of plate T.O. FTG top of footing T.O.S. top of steel T.O.SL. top of slab T.O.W. top of wall TPD toilet paper dispenser TR tread TS tubular steel TV television TYP typical UG underground UNO unless noted otherwise UR urinal VAC vacuum outlet VAR varies VB vapor barrier VCT vinyl composition tile VERT vertical VEST vestibule VFY verify VT vinyl tile VWC vinyl wall covering W west/women/width W/ with W/O without WC water closet WD wood W/D washer/dryer WH water heater WNDW window WP waterproof WR water resistant WRB weather resistive barrier WT weight WWF welded wire fabric WWM welded wire mesh X by YD yard
REINF reinforcing REQD required RES resilient RM room RO rough opening RV roof vent R&S rod and shelf S south SACT suspended acoustical ceiling tile SC solid core SCD seat cover dispenser SCHED schedule SD soap dispenser SECT section SF square feet SGL single SHT sheet SHTG sheathing SHWR shower SIM. similar S.I.P. structural insulated panel SLNT sealant SOG slab on grade SPEC specifications S.S. stainless steel SS service sink SSM solid surface material STD standard STF storefront STL steel STOR storage STRUCT structural SUBFLR subfloor SUSP suspended SV sheet vinyl SY square yard
M men's MAT material MAX maximum MECH mechanical MDF medium density fiber board MEMB membrane MEZZ mezzanine MFR manufacturer MH manhole MIN minimum MIR mirror MISC miscellaneous MO masonry opening MTL metal MULL mullion N north NA not applicable NIC not in contract NO number NTS not to scale OFCI owner furnished/contractor installed OC on center OD outside diameter OH overhead/opposite hand OPNG opening OPP opposite
FLR/FL floor FLUOR fluorescent FND feminine napkin dispenser/disposal FOC face of concrete FOF face of finish FOS face of stud FOW face of wall FT foot or feet FTG footing
QTY quantity R/RAD radius R riser RA roof/ceiling assembly RB rubber base RD roof drain RE regarding REF reference/refrigerator
JAN janitor JST joist JT joint LAV lavatory LF lineal foot LTG lighting
FA fire alarm/floor-ceiling assembly FAH fire alarm horn FAS fire alarm station FD floor drain FDN/FND foundation FE fire extinguisher FEC fire extinguisher cabinet FF finished floor FFHB frost free hose bib FG finish grade FH fire hydrant FIN. FLR top of floor sheathing FIN finish FIXT fixture F.O. face of
PTD/R paper towel dispenser/receptacle PVMT pavement PVC polyvinylchloride
SCALE
BUILDING SECTIONS
WALL SECTIONS
EXTERIOR ELEVATION
DETAIL CALLOUT
INTERIOR ELEVATION
DOOR NUMBER
WINDOW TYPE
ROOM NAME, NUMBER, AND
AREA
GRID LINES:
LETTERS LEFT TO RIGHT
NUMBERS TOP TO BOTTOM
WALL TYPE
ELEVATION TAG, FLOOR = 100' - 0"
REFERENCE SYMBOLS:
DRAWING TITLE
STOREFRONT/CURTAINWALL
CALLOUT
TEXT INDICATES STOREFRONT
SYSTEM:
iSF = INTERIOR STOREFRONT
SF = EXTERIOR STOREFRONT
CW = CURTAINWALL
FIRE EXTINGUISHER, SEE CODE
PLANS
SHEET
NUMBER
DRAWING
NUMBER
SHEET
NUMBER
DRAWING
NUMBER
SHEET NUMBER
DRAWING
NUMBER
SHEET NUMBER
DRAWING
NUMBER
SHEET NUMBER
DRAWING NUMBER
FE
WITH CABINET
WALL-HUNG, NO
CABINET
ROOF TYPE
-SEE ELEVATIONS FOR HEIGHTS
"SIM" INDICATES SIMILAR
CONDITION; SEE NOTES
FLOOR TYPE
A7-14
A3-8
A5-2
VIEW NAME
1/8" = 1'-0"
A
Room name
A
101A
A1-1
A1-1
FA1
Name
Elevation
RA1
SIM
cw1 i1
1. GENERAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING DIMENSIONS & CONDITIONS.
EXISTING DIMENSIONS SHOWN ARE APPROXIMATE AND MUST BE FIELD VERIFIED.
2. REFER TO SPECIFICATIONS FOR DETAILED DESCRIPTIONS & REQUIREMENTS OF
CONSTRUCTION.
3. GENERAL CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES, PROVIDE ON-SITE
SUPERVISION & BE RESPONSIBLE FOR COMPLIANCE WITH ALL SAFETY PRECAUTIONS, CODES
AND REGULATIONS.
4. PROTECT EXISTING UTILITIES, SITE IMPROVEMENTS & PLANTING TO REMAIN.
5. PATCH ANY SURFACES DAMAGED DURING CONSTRUCTION. SURFACES ARE TO BE PATCHED
FLUSH WITH EXISTING. MATCH EXISTING ADJACENT FINISH OR APPLY NEW FINISH AS
SCHEDULED.
6. PROVIDE SOLID BACKING FOR ALL WALL-MOUNTED ITEMS.
7. IN GENERAL, REPETITIVE DETAILS DRAWN ARE SHOWN IN FULL ONLY ONCE. REPETITIONS MAY
NOT BE COMPLETE IN EVERY DETAIL AS SHOWN IN THE ORIGINAL DETAIL.
8. DIMENSIONS ARE SHOWN ON THE DRAWINGS. DO NOT SCALE THE DRAWINGS.
9. ALL HEIGHTS ARE DIMENSIONED FROM THE TOP OF SUBFLOOR UNLESS NOTED OTHERWISE.
10. WHERE COLUMNS & STUD WALLS ALIGN, GYPSUM BOARD TO BE CONTINUOUS OVER COLUMNS
OR BOXED AROUND COLUMN IF COLUMN PROJECTS BEYOND WALL.
11. BRING TO THE ATTENTION OF THE ARCHITECT ANY CONDITION OR AREA OF FINISH THAT IS IN
QUESTION OR NOT NOTED.
12. SEAL ALL PENETRATIONS OF WALLS, FLOORS AND CEILINGS WITH A FIRE RATING EQUIVALENT
TO THE CONSTRUCTION PENETRATED AND PER DETAILS & SPECIFICATIONS.
13. DUST BARRIERS MUST BE INSTALLED WHEREVER NEW WORK IS ADJACENT TO OCCUPIED
AREAS. BARRIERS MUST BE SEALED TO INSURE NO DUST TRANSMISSION TO OCCUPIED SPACES.
14. COORDINATE LAYOUT, CLEARANCES, PENETRATIONS, BACKING & FASTENERS WITH WORK TO
FOLLOW.
15. HEATING, PLUMBING AND ELECTRICAL PLANS WHERE SHOWN DIAGRAMMATICALLY ARE
INTENDED TO INDICATE CAPACITY, SIZE, LOCATION & GENERAL ARRANGEMENTS. ALL
NECESSARY FEATURES OF RELATED CONSTRUCTION WILL BE REQUIRED AS IF SHOWN IN
DETAIL.
16. WHERE MECHANICAL & ELECTRICAL EQUIPMENT LOCATIONS CONFLICT ELECTRICAL, LIGHT
FIXTURE LOCATIONS SHALL TAKE PRECEDENCE.
17. PROVIDE SUFFICIENT STUD DEPTH TO CONCEAL MECHANICAL & ELECTRICAL WORK IN WALLS.
18. PROVIDE ALL NEW MATERIALS (U.N.O.) AND QUALIFIED CRAFT PERSONS TO COMPLETE THE
WORK.
19. CONSTRUCTION DOCUMENTS SHOW THE DESIGN INTENT OF THE PROJECT AND MAY NOT SHOW
MINOR DETAILS OF PROPOSED INSTALLATIONS. THE INCLUSION OF THESE MINOR DETAILS IS
IMPLIED TO PROVIDE A COMPLETE PROJECT AND ARE TO BE INCLUDED AS A PART OF A BID.
20. REFER TO MECHANICAL & ELECTRICAL DRAWINGS FOR COORDINATION OF WORK.
21. IN THE CASE OF CONTRADICTIONS BETWEEN DRAWINGS OR BETWEEN DRAWINGS &
SPECIFICATIONS, ASSUME THE MORE COSTLY APPROACH FOR BIDDING PURPOSES. BRING ALL
CONTRADICTIONS TO THE ATTENTION OF THE ARCHITECT.
22. CONTRACTOR SHALL PROMPTLY REMOVE ALL WASTE MATERIALS AND LEAVE PREMISES AND
SITE CLEAN.
23. THE CONTRACTOR SHALL PROVIDE ALL CEILING AND/OR WALL ACCESS PANELS/DOORS AS
REQUIRED BY THE AIR CONDITIONING, PLUMBING & ELECTRICAL SYSTEMS, PROVIDE APPROVED ASSEMBLIES W/ SELF-CLOSING DEVICES IN RATED CONSTRUCTION. (PAINT TO MATCH ADJACENT
WALL COLOR)
24. ELECTRICAL OUTLETS AND LIGHTING ARE ONLY SHOWN ON ARCHITECTURAL "A" SHEETS WHERE
PLACEMENT OF SUCH IS CRITICAL TO PARTICULAR AESTHETICS. SEE ELECTRICAL DRAWINGS
FOR ALL ELECTRICAL AND DATA FEATURES.
DRAWING SET NOTE: THESE DRAWINGS ARE TO BE UTILIZED AS A COMPLETE SET FOR BIDDING &
CONSTRUCTION. INDIVIDUAL SECTIONS OF DRAWINGS SHOULD NOT BE SEPARATED FROM THE
ENTIRE SET. IMPORTANT NOTES FOR ONE AREA OF WORK MAY BE INCLUDED IN OTHER AREAS IN
THE DRAWINGS. ALL CONTRACTORS & SUPPLIERS MUST REVIEW ENTIRE DRAWING SET &
SPECIFICATIONS.
GENERAL NOTES:
GENERAL WALL NOTES
1. WALL TYPE CONSTRUCTION IS CONTINUOUS FROM SLAB TO ROOF FRAMING ABOVE UNLESS INDICATED OTHERWISE.
2. IF A WALL TYPE IS NOT INDICATED, PROVIDE WALL TYPE OF MOST SIMILAR CONDITION - VERIFY WITH ARCHITECT.
3. IN CASES OF CONFLICT BETWEEN SECTIONS AND WALL TYPES, CLARIFY WITH ARCHITECT PRIOR TO BIDDING WHEN TIME ALLOWS, OTHERWISE ASSUME THE MOST EXPENSIVE CONDITION FOR BIDDING PURPOSES.
4. STRUCTURAL NOTES, SPECIFICATIONS, STUD GAUGE NOTATIONS ETC. TAKE PRECEDENCE OVER ARCHITECTURAL WALL TYPES.
5. FOR LIGHT GAUGE (NON-STRUCTURAL) METAL FRAMING, PROVIDE MIN. 22 GAUGE STUDS UNLESS THE CONTRACTOR CAN PROVIDE
MANUFACTURER'S DATA SUPPORTING LIGHTER GAUGE STUDS BASED ON HEIGHT AND FINISH MATERIALS.
6. ALL VOIDS IN EXTERIOR WALLS - INCLUDING IN NON-VISIBLE LOCATIONS - TO BE FILLED TIGHT WITH INSULATION. SMALL CRACKS &
VOIDS TO BE CAULKED OR SPRAY-FOAMED FOR TIGHT SEAL.
7. ALL EXTERIOR WALLS TO RECEIVE VAPOR BARRIER UNDER INTERIOR FINISH. ALL SEAMS OF VAPOR BARRIER MUST BE TAPED/SEALED
TIGHT AND ALL JOINTS MUST BE TAPED/ SEALED TIGHT WITH MATERIALS AND METHODS APPROVED BY VAPOR BARRIER MFR.
8. TYPE "X" GYPSUM WALL BOARD SPECIFIED THROUGHOUT. PROVIDE WATER-RESISTANT TYPE "X" GYPSUM BOARD ON ENTIRE WALL
WHERE PLUMBING FIXTURES OCCUR. PROVIDE TILE BACKER BOARD TYPE "X" ON ALL WALLS WITH TILE.
9. WALLS INDICATED WITH ACOUSTICAL INSULATION TO MEET AN STC RATING OF 48 OR MORE, UNLESS OTHERWISE INDICATED.
10. PROVIDE SOUND ATTENUATION INSULATION ON TOP OF ACT WHERE WALLS TERMINATE AT CEILING OR 6" ABOVE CEILING. EXTEND 5
FEET TO BOTH SIDES OF WALL. HOLD INSULATION 7" AWAY FROM LIGHT FIXTURES.
11. PROVIDE BACKER ROD & CAULKING JOINT AT ABUTMENT OF ALL DISSIMILAR MATERIALS.
12. PROVIDE STEEL "J" EDGE METAL AND 1/4" CAULK JOINT AT PERIMETER OF ALL GYPSUM BOARD WALLS WHERE ABUTTING DIFFERENT
MATERIALS.
13. PROVIDE CORNER BEADS AT ALL EXTERNAL GYPSUM BOARD CORNERS.
14. PENETRATIONS OF FIRE-RESISTIVE WALLS, HORIZONTAL ASSEMBLIES SHALL BE PROTECTED AS REQUIRED IN IBC SECTION 714.
15. PROVIDE FIRE, SMOKE AND CEILING RADIATION DAMPERS AT DUCT PENETRATIONS AND AIR TRANSFER OPENINGS IN FIRE RATED
ASSEMBLIES PER IBC SECTION 717.
CEILING TYPE PER
REFLECTED CEILING
PLAN
ACOUSTIC BATT
INSULATION WHERE
OCCURS PER WALL TYPE
SEALANT
WALL TYPE PER PLAN
3 1/2" 25 GA. STUD
BRACING TO STRUCTURE
@ MAX 4'-0" OC,
ALTERNATING SIDES. NO
WOOD ABOVE CEILINGS
STRUCTURE ABOVE
45° MAX
6"
SCHEDULED BASE
PARTITION WALL BRACING
REMOVE CARPET JUST
BELOW WALL, COVER W BASE
R-21 FACED BATTS OVER
OFFICE
5/8" GYPSUM BOARD
TYPE X
3 5/8" MTL STUDS OR 2X4
WD STUDS @ 16" O.C.
(2) 5/8" GYPSUM BOARD
TYPE X
ACOUSTICAL BATT
INSULATION
5/8" GYPSUM BOARD
TYPE X
6" MTL STUDS @ 16"
OC
5/8" GYPSUM BOARD
TYPE X
NOTE: SEE ELEVATIONS AND FINISH SCHEDULES FOR
WALL FINISHES, TYPICAL ALL WALL TYPES
ACOUSTICAL BATT
INSULATION
INTERIOR WALL TYPES
INTERIOR PARTITION INTERIOR PARTITION
NON-RATED SOUND WALL NON-RATED SOUND WALL
5/8" GYPSUM
BOARD TYPE X
3 5/8" MTL STUDS
@ 16" O.C.
5/8" GYPSUM
BOARD TYPE X
5/8" GYPSUM
BOARD TYPE X
6" MTL STUDS @
16" OC
5/8" GYPSUM
BOARD TYPE X
INTERIOR PARTITION INTERIOR PARTITION
NON-RATED NON-RATED
i1 i2 i3 i4
DATE:
SHEET:
317 N. Cruse Ave., Suite 201 Helena, Montana 59601
406.449.2013phone
406.449.2036fax www.mosaicarch.com
D A
T E
S T
A M
P a r c h i t e c t u r e - p l a n n i n g -d e s i g n
/7
/2
:3
:1
A M
8.04.2023
A000
COVER
26 FORT MISSOULA RD, MISSOULA,
MT
BUILDING 26
RENO.
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
BUILDING 26 - OFFICE/
CONFERENCE REMODEL
26 FORT MISSOULA RD,
MISSOULA, MT
MOSAIC ARCHITECTURE, P.C.
317 CRUSE AVE., SUITE 201
HELENA, MT 59601
(406) 449-2013 CONTACT: BEN TINTINGER, AIA ben@mosaicarch.com
ARCHITECT:
THESE DRAWINGS WERE PREPARED BY MOSAIC ARCHITECTURE, P.C. FOR CONSTRUCTION OF THE PROJECT DESCRIBED HEREIN. AS SUCH, THE DOCUMENTS ARE THE PROPERTY OF MOSAIC ARCHITECTURE, P.C. & MAY NOT BE REPRODUCED, COPIED OR USED IN ANY WAY WITHOUT PRIOR APPROVAL FROM MOSAIC ARCHITECTURE, P.C.
SHEET INDEX
PROJECT DIRECTORY
VICINITY MAP
PROJECT
SITE
ARCHITECTURAL DRAWINGS
A000 COVER
A101 FLOOR PLAN - OFFICE
A103 FLOOR PLAN - CONFERENCE
MECHANICAL/PLUMBING ENGINEERING:
MORRISON MAIERLE
1055 Mount Avenue
MISSOULA MT 59801
(406) 751-5867
CONTACT: ROSS BALFOUR , PE rbalfour@m-m.net
ELECTRICAL ENGINEERING:
CONTACT: GARTH STEVENS, PE gstevens@m-m.net
MORRISON MAIERLE
1055 Mount Avenue
MISSOULA MT 59801
(406) 751-5867
Fort M is soula
R oad
ELECTRICAL DRAWINGS
E001 ELECTRICAL SYMBOLS AND ABBREVIATIONS
E002 ELECTRICAL SPECIFICATIONS
E003 ELECTRICAL SPECIFICATIONS
E101 POWER/SIGNAL PLAN - OFFICE
E102 POWER/SIGNAL PLAN - CONFERENCE
E201 LIGHTING PLAN - OFFICE
E202 LIGHTING PLAN - CONFERENCE
MECHANICAL DRAWINGS
M001 MECHANICAL LEGEND AND NOTES
M002 MECHANICAL SPECIFICATIONS
M003 MECHANICAL SPECIFICATIONS
M101 MECHANICAL FLOOR PLAN - OFFICE
M103 MECHANICAL FLOOR PLAN - CONFERENCE
# DATE REVISION
e2s
WALL TYPE
WALL HEIGHT
WALL STUD & FINISH HEIGHT
c GWB TO 6" ABOVE CEILING; FRAME OR BRACE TO STRUCTURE e EXTERIOR - SEE SECTIONS f FURRING p PARTIAL HEIGHT s TO STRUCTURE x SHAFT - CONTINUOUS THROUGH FLOOR ASSEMBLIES
WALL TYPE TAG
KJIH
ACT
10' - 0"
ACT
10' - 0"
SEE MEP FOR RELOCATION OF
LIGHTING AND MEP DEVICES
s
MODIFY EXISTING CLG SYSTEM
TO EXTEND NEW WALLS ABOVE
CEILING, SEE DETAIL. REMOVE AND
MODIFY MAIN AND SECONDARY
GRID COMPONENTS AS REQUIRED.
PROVIDE NEW EDGE TRIM AT NEW
WALLS. CONTRACTORS OPTIONS
TO FULLY REPLACE CEILING
SYSTEM IN OFFICE ROOM
KJIH
12' - 4 7/8"
A
A101 i1 i1
7'
5/
8"
/8
/2
TYPE A 36X84
EXISTING CARPET TO
REMAIN. PROTECT CARPET
DURING CONSTRUCTION.
REMOVE AS NEEDED FOR
NEW WALLS
NEW DOOR TYPE A TO MATCH
EXISTING DOORS AND TRIM.
PLACEMENT OF NEW DOOR TO TAKE
INTO CONSIDERATION THE ADJACENT
DOOR TRIM & BASE TRIM.
1/
2"
327 SF
EXEC. ASSIST
116A
122 SF
OFFICE
116B
KJIH
4'
0"
2' - 6" 3' - 11 7/8" 1' - 11 7/8"
4'
/8
8'
3/
4" 1'
3/ 8"
9'
/8
5'
6" 1'
6"
7'
0"
2' - 6" 3' - 1 1/2" 3' - 2" 2' - 0"
12' - 3 5/8"
FURNITURE
BY OWNER
FURNITURE
BY OWNER
NEW DOOR TRIM TO MATCH
EXISTING DOOR TRIM
DOOR TO MATCH
EXISTING DOORS
MATCH NEW TRIM TO THE
EXISTING TRIM: 1X8 PAINTED
BASE WITH QUARTER ROUND
1. GENERALLY CENTER CEILING GRIDS IN EACH ROOM AS SHOWN
ON PLANS TO PROVIDE EQUALLY SIZED PANELS ON OPPOSITE
WALLS. IF PLANS INDICATE A GRID ALIGNING WITH A COLUMN,
WALL, SOFFIT, ETC., START GRID AT INDICATED SURFACE.
2. SEE FLOOR PLAN FOR WALL TYPES AND WALLS THAT EXTEND
FULL HEIGHT TO STRUCTURE.
3. CEILING FIXTURES ARE SHOWN FOR REFERENCE ONLY FOR
COORDINATION WITH CEILING FINISH SYSTEM.
4. SPOT ELEVATIONS ARE FROM FINISH FLOOR TO SURFACE FINISH
OF CEILING AND ARE ROUNDED TO THE NEAREST INCH.
GENERAL CEILING NOTES
CEILING LAYOUT NOTES: LAY-IN CEILINGS ARE SHOWN CONCEPTUALLY.
IT IS THE INTENT THE CEILINGS AREA CENTERED WITHIN THE ROOM. IN
ODD SHAPED ROOMS, PRIMARY VISUAL AREA TO BE CENTERED. CEILNG
INSTALLER SHOULD CONSULT WITH THE ARCHITECT IN THE FIELD FOR
ANY AREAS IN WHICH THEY WOULD LIKE TO MODIFY THE LAYOUT FROM
THAT SHOWN ON THE PLAN. MODIFICATIONS MAY BE ALLOWED, AT THE
DISCRETION OF THE ARCHITECT, TO EASE INSTALLATION, SAVE CUTTING,
OR INCREASE VISUAL APPEAL.
CEILING LEGEND
GWB 5/8" TYPE "X" GYPSUM WALLBOARD ON
STL. FRAMING - SEE DETAILS. PAINT P1
UNO
ACT 2x2 CEILING TILES
1. DIMENSIONS ARE TO FACE OF STUD, EXISTING WALL FINISH,
MASONRY, OR DOOR/WINDOW OPENINGS. DIMENSIONS OF EXISTING
CONSTRUCTION ARE NOT SHOWN ON DRAWINGS - VERIFY
DIMENSIONS OF ALL EXISTING CONSTRUCTION IN THE FIELD.
DIMENSIONS TO OPENINGS ARE NOMINAL. VERIFY ALL OPENINGS
WITH ROUGH OPENING REQUIREMENTS.
2. ALL DOOR OPENINGS PERPENDICULAR TO A WALL ARE 4" TO THE
WALL FRAMING UNO.
3. EXISTING CONSTRUCTION TO REMAIN SHOWN SHADED, NEW
CONSTRUCTION SHOWN SOLID.
4. SEE SHEET A-000 FOR WALL TYPES. IN AREAS WITH SUSPENDED
ACOUSTICAL TILE CEILINGS, GYPSUM WALL BOARD MAY BE
TERMINATED 6" ABOVE THE CEILING.
5. VERIFY EXISTING WALL CONSTRUCTION.
6. EXISTING CARPET TO REMAIN, PROTECT DURING CONSTRUCTION.
GENERAL FLOOR PLAN NOTES
NEW CONSTRUCTION
EXISTING ELEMENTS TO REMAIN
LINEWORK LEGEND
J
MATCH NEW TRIM TO THE
EXISTING TRIM: 1X8 PAINTED
BASE TRIM W QUARTER ROUND,
FIELD VERIFY DIMENSIONS
8" 4"
7'
0"
JAMB TRIM
TIGHT TO ADJ.
SURFACES
HEAD TRIM
TIGHT TO
ADJ. SURFACE
RENOVATION NOTES
REPAINT WALL
END REPAINTING AT INSIDE CORNER
3 REMOVE BASE TRIM FOR NEW WALL CONSTRUCTION, MODIFY AND
REINSTALL REPAINT
2'
3/
8"
1' - 8 1/8"
NEW 5" VERTICAL TRIM
EX. HORIZ TRIM, CUT
BACK AND ABUT TO NEW
VERTICAL TRIM
QUARTER ROUND
@ FLOOR, MOD.
AS REQ'D
DOUBLE ACTING
HINGE
EXISTING TRIM
2X6
SHIM SPACE
1" X 5 9/16" WOOD
FRAME
3' - 4 1/4"
FACE TO FACE GYP.
3' - 6"
NEW PANEL
DOOR
HEAD CONDITION
SIMILAR
REPAINT EXISTING TRIM
TO NEAREST CORNER.
TYPICAL
DATE:
SHEET:
317 N. Cruse Ave., Suite 201 Helena, Montana 59601
406.449.2013phone
406.449.2036fax www.mosaicarch.com
D A
T E
S T
A M
P a r c h i t e c t u r e - p l a n n i n g -d e s i g n
/7
/2
:3
:1
A M
8.04.2023
A101
FLOOR PLAN - OFFICE
26 FORT MISSOULA RD, MISSOULA,
MT
BUILDING 26
RENO.
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
N 1/4" = 1'-0"
RCP - OFFICE
21/4" = 1'-0"
FLOOR PLAN - OFFICE AREA
1/4" = 1'-0"
FURNITURE PLAN - OFFICE AREA
1/4" = 1'-0"
OFFICE - ELEVATION A
4 1/4" = 1'-0"
OFFICE -ELEVATION B
EXISTING TRIM EXAMPLE
1/2" = 1'-0"
DOOR TYPE
@ OFFICE - INTERIOR STYLE AND RAIL
6 PANEL WOOD DOOR
RAISED WOOD
PANELS
5" X 7/8" TRIM, PAINTED
SLIGHTLY EASED
EDGES, MITER CORNERS
DOOR TYPE A
HARDWARE:
DOOR 116: 3 HINGES, OFFICE LEVER HANDLE LOCKSET, DOME FLOOR STOP
DOOR 121: 3 - 6" DOUBLE ACTING HINGES (100MM), DUMMY LEVERSET, KICK-DOWN DOOR
STOP WITH FOOT RELEASE, (2) DOME FLOOR STOPS
ALL HARDWARE TO HAVE "OIL RUBBED BRONZE" FINISH. IF FINISH NOT AVAILABLE FOR
DOUBLE ACTING HINGES, USE CLOSEST DARK MATTE FINISH AVAILABLE
1 1/2" = 1'-0"
NEW DOOR @ EX. OPENING
DOOR TYPE A
@ CONFERENCE - INTERIOR STYLE AND RAIL
6 PANEL WOOD DOOR
# DATE REVISION
DN
32' - 0 1/2"
SEATS: 38
SCREEN
K
JIH
ACT
11' - 0"
K
JIH
A
A103
1151 SF
OFFICE/CONF ROOM
3' - 9"
5'
3" 5'
4'
9"
6'
3"
FLOOR PLAN LINE LEGEND - UNDER CARPET POWER/DATA
TRACK SYSTEM
PURPLE DASH LINE INDICATES TRACK LOCATION, SEE ELECT.
RED DASH LINE INDICATES UNDER-CARPET TRANSITION RAMP
SYSTEM. REMOVE CARPET TILE AND REINSTALL OVER RAMP SYSTEM
ROUNDED END
UNDER-CARPET "RAMP"
TRACK ENTRANCE: PROVIDE
IN-WALL ENTRANCE FITTINGS,
NOTCH EXISTING BASE TRIM
AROUND FITTING
POWER TRACK RAMP
RADIUS AT TRACK ENDS
A103
TYP.
2 J I
1. GENERALLY CENTER CEILING GRIDS IN EACH ROOM AS SHOWN
ON PLANS TO PROVIDE EQUALLY SIZED PANELS ON OPPOSITE
WALLS. IF PLANS INDICATE A GRID ALIGNING WITH A COLUMN,
WALL, SOFFIT, ETC., START GRID AT INDICATED SURFACE.
2. SEE FLOOR PLAN FOR WALL TYPES AND WALLS THAT EXTEND
FULL HEIGHT TO STRUCTURE.
3. CEILING FIXTURES ARE SHOWN FOR REFERENCE ONLY FOR
COORDINATION WITH CEILING FINISH SYSTEM.
4. SPOT ELEVATIONS ARE FROM FINISH FLOOR TO SURFACE FINISH
OF CEILING AND ARE ROUNDED TO THE NEAREST INCH.
GENERAL CEILING NOTES
CEILING LAYOUT NOTES: LAY-IN CEILINGS ARE SHOWN CONCEPTUALLY.
IT IS THE INTENT THE CEILINGS AREA CENTERED WITHIN THE ROOM. IN
ODD SHAPED ROOMS, PRIMARY VISUAL AREA TO BE CENTERED. CEILNG
INSTALLER SHOULD CONSULT WITH THE ARCHITECT IN THE FIELD FOR
ANY AREAS IN WHICH THEY WOULD LIKE TO MODIFY THE LAYOUT FROM
THAT SHOWN ON THE PLAN. MODIFICATIONS MAY BE ALLOWED, AT THE
DISCRETION OF THE ARCHITECT, TO EASE INSTALLATION, SAVE CUTTING,
OR INCREASE VISUAL APPEAL.
CEILING LEGEND
GWB 5/8" TYPE "X" GYPSUM WALLBOARD ON
STL. FRAMING - SEE DETAILS. PAINT P1
UNO
ACT 2x2 CEILING TILES
1. DIMENSIONS ARE TO FACE OF STUD, EXISTING WALL FINISH,
MASONRY, OR DOOR/WINDOW OPENINGS. DIMENSIONS OF EXISTING
CONSTRUCTION ARE NOT SHOWN ON DRAWINGS - VERIFY
DIMENSIONS OF ALL EXISTING CONSTRUCTION IN THE FIELD.
DIMENSIONS TO OPENINGS ARE NOMINAL. VERIFY ALL OPENINGS
WITH ROUGH OPENING REQUIREMENTS.
2. ALL DOOR OPENINGS PERPENDICULAR TO A WALL ARE 4" TO THE
WALL FRAMING UNO.
3. EXISTING CONSTRUCTION TO REMAIN SHOWN SHADED, NEW
CONSTRUCTION SHOWN SOLID.
4. SEE SHEET A-000 FOR WALL TYPES. IN AREAS WITH SUSPENDED
ACOUSTICAL TILE CEILINGS, GYPSUM WALL BOARD MAY BE
TERMINATED 6" ABOVE THE CEILING.
5. VERIFY EXISTING WALL CONSTRUCTION.
6. EXISTING CARPET TO REMAIN, PROTECT DURING CONSTRUCTION.
GENERAL FLOOR PLAN NOTES
FLOOR TRACKS W COVER
PLATES
TAPERED RAMP:
16" MIN. LENGTH
TAPERED RAMP
EXISTING CARPET
TILES REINSTALLED
OVER RAMP
POWER & DATA
BOXES
ABOVE FLOOR POWER TRACK DESIGN
BASED ON LEGRAND "CONNECTRAC" FLEX
SYSTEM WITH IN-WALL TRANSITION,
COVER PLATES, TRANSITION RAMPS AND
END RAMPS. SEE ELECTRICAL FOR DATA
AND POWER DEVICES.
DATE:
SHEET:
317 N. Cruse Ave., Suite 201 Helena, Montana 59601
406.449.2013phone
406.449.2036fax www.mosaicarch.com
D A
T E
S T
A M
P a r c h i t e c t u r e - p l a n n i n g -d e s i g n
/7
/2
:3
:1
A M
8.04.2023
A103
FLOOR PLAN -
CONFERENCE
26 FORT MISSOULA RD, MISSOULA,
MT
BUILDING 26
RENO.
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
1/8" = 1'-0"
FURNITURE PLAN - CONFERENCE
1/4" = 1'-0"
RCP - CONFERENCE
1/4" = 1'-0"
FLOOR PLAN - CONFERENCE
1/4" = 1'-0"
CONFRENCE ROOM - SOUTH
5 1/4" = 1'-0"
CONFRENCE ROOM - WEST
PHOTO 1
PHOTO 1 - CONFERENCE ROOM PHOTO 2 - CONFERENCE ROOM PHOTO 3 - CONFERENCE ROOM
PHOTO 3
PHOTO 2
EXISTING COL.
PROTECT FINISHES,
TYPICAL
1" = 1'-0"
FLOOR POWER TRACK INSTALL
# DATE REVISION
NEW ONE HOUR
FIRE DOOR
NEW PANEL DOOR
Add New Wall according to details listed on A101
Can bring power from north or south wall for convenience mmsandall Line mmsandall Line mmsandall Line mmsandall Line mmsandall Stamp mmsandall Line mmsandall Line mmsandall Stamp mmsandall Line mmsandall Line mmsandall Line mmsandall Line mmsandall Line
HUMIDISTATH
THERMOSTAT W/ LOCKABLE COVERT
CARBON MONOXIDE / NITRIC OXIDE SENSORCO/NO
DUCT UP (PLAN VIEW)
DUCT DOWN (PLAN VIEW)
RECTANGULAR DUCT
WIDTH x DEPTH
W"xD"
ROUND DUCT
DIAMETER
X"ø
X"ø
FLEXIBLE DUCT
DIAMETER
R INCLINED RISE - IN DIRECTION OF AIRFLOW
D INCLINED DROP - IN DIRECTION OF AIRFLOW
INTERNAL DUCT LINING
ELBOW WITH TURNING VANES
RADIUS ELBOW
W"/D"
OVAL DUCT
WIDTH/DEPTH
SUPPLY DUCT (SECTION VIEW)
RETURN DUCT (SECTION VIEW)
EXHAUST DUCT (SECTION VIEW)
OUTDOOR AIR DUCT (SECTION VIEW)
MANUAL VOLUME DAMPER
BACKDRAFT DAMPER
ZONE DAMPER
BYPASS DAMPER
MOTORIZED DAMPER
FIRE DAMPER
FIRE/SMOKE DAMPER
SMOKE DAMPER
Z B
M F
F S
S
FLOOR/CEILING SUPPLY DIFFUSER
FLOOR/CEILING RETURN GRILLE
FLOOR/CEILING EXHAUST GRILLE
REMOTE VOLUME DAMPER
SIDEWALL SUPPLY DIFFUSER
SIDEWALL RETURN/EXHAUST GRILLE
HVAC DUCTWORK
STATIC PRESSURE SENSORSP
DIFFERENTIAL PRESSURE SENSORDP
BUILDING PRESSURE SENSOR
ANNOTATION SYMBOLS
X
X
X
X
CFM
X
DETAIL NUMBER
SHEET NUMBER
SECTION NUMBER
SHEET NUMBER
AIR DEVICE MARK AND CFM
ME-# MECHANICAL EQUIPMENT MARK
POINT OF NEW CONNECTION
POINT OF DISCONNECTION
THERMOSTATT
ZONED THERMOSTATT
ZONED THERMOSTAT - MASTERT
ROOM HUMIDITY SENSOR
ROOM CO2 SENSOR
$ WALL SWITCH
CFM
X AIR DEVICE MARK AND CFM -
PROVIDE OPPOSED BLADE DAMPER
OBD
CFM
X AIR DEVICE MARK AND CFM -
PROVIDE RADIAL DAMPER
RD
X
X
3D VIEW NUMBER
SHEET NUMBER
#M
MECHANICAL LEGEND
R B
D
ROOM TEMPERATURE SENSOR
HVAC CONTROL SYMBOLS
NOTE: THIS IS A STANDARD LEGEND. NOT ALL PIPE TYPES AND
SYMBOLS ARE NECESSARILY UTILIZED IN THE DRAWINGS.
ID INSIDE DIAMETER
IFB INTEGRAL FACE & BYPASS
IGV INLET GUIDE VANES
IPS IRON PIPE SIZE
IU INDUCTION UNIT
KW KILOWATTS
KWH KILOWATT HOUR
LAT LEAVING AIR TEMPERATURE (°F)
LF LINEAR FEET
LWT LEAVING WATER TEMPERATURE (°F)
M MOTOR OPERATED
MAU MAKEUP AIR UNIT
MB MIXING BOX
MBH 1000 BTU/HR
MC MECHANICAL CONTRACTOR
MFR MANUFACTURER
MS MINI-SPLIT
NC NOISE CRITERIA
NC NORMALLY CLOSED
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NPS NOMINAL PIPE SIZE
OA OUTSIDE AIR
OAD OUTSIDE AIR DAMPER
OBD OPPOSED BLADE DAMPER
P PUMP
PC PLUMBING CONTRACTOR
PD PRESSURE DROP
PH PHASE
PHC PREHEAT COIL
PPM PART PER MILLION
PROP PROPELLER
PRV PRESSURE REDUCING VALVE
PSIA PSI, ABSOLUTE
PSIG PSI, GAUGE
QTY QUANTITY
R REGISTER
RA RETURN AIR
RD RADIAL DAMPER
RF RETURN/RELIEF AIR FAN
RH RELATIVE HUMIDITY
RHC REHEAT COIL
SA SUPPLY AIR
SAF SUPPLY AIR FAN
SC SENSIBLE COOLER
SCFM CFM, STANDARD CONDITIONS
SD SMOKE DETECTOR
SEER SEASONAL ENERGY EFFICIENCY RATIO
SENS SENSIBLE
SP STATIC PRESSURE
SPS STATIC PRESSURE SENSOR
SS STAINLESS STEEL
T THERMOSTAT
TA TRANSFER AIR
TCC TEMPERATURE CONTROL CONTRACTOR
TCP TEMPERATURE CONTROL PANEL
TG TRANSFER GRILL
TOD TOP OF DUCT
TOP TOP OF PIPE
TOS TOP OF STEEL
TSP TOTAL STATIC PRESSURE
TYP TYPICAL
UH UNIT HEATER
UNC UNDERCUT
UV UNIT VENTILATOR
VA VOLT-AMPERE
VAV VARIABLE AIR VOLUME
VD VOLUME DAMPER
VEL VELOCITY
VFD VARIABLE FREQUENCY DRIVE
VRF VARIABLE REFRIGERANT FLOW
WB WET BULB TEMPERATURE (°F)
WC WATER COLUMN
WG WATER GAUGE
WSHP WATER SOURCE HEAT PUMP
ΔT TEMPERATURE DIFFERENCE (°F)
ACC AIR COOLED CONDENSER
ACU AIR CONDITIONING UNIT
AD ACCESS DOOR
ADJ ADJUSTABLE
AF AIR FOIL
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFR ABOVE FINISHED ROOF
AFS AIR FLOW STATION
AHU AIR HANDLING UNIT
AP ACCESS PANEL
ATC AUTOMATIC TEMPERATURE CONTROL
ATM ATMOSPHERE
AWG AMERICAN WIRE GAUGE
B BOILER
BB BASEBOARD
BC BACKWARD CURVED
BD BACKDRAFT DAMPER
BF BOILER FEED
BHP BRAKE HORSEPOWER
BI BACKWARD INCLINED
BMS BUILDING MANAGEMENT SYSTEM
BOD BOTTOM OF DUCT
BOJ BOTTOM OF JOIST
BOS BOTTOM OF STEEL
BTU BRITISH THERMAL UNIT
C COMMON
CAV CONSTANT AIR VOLUME
CC COOLING COIL
CCW COUNTER CLOCKWISE
CFM CUBIC FEET PER MINUTE
CH CHILLER
C&I CONTROLS & INSTRUMENTATION
CLG CEILING
CMU CONCRETE MASONRY UNIT
CND CONDENSATE
CONT CONTINUATION
CORR CORRIDOR
CT COOLING TOWER
CU CONDENSING UNIT
CH CABINET HEATER
CV CONTROL VALVE
CVS CONTROL VALVE STATION
CW CLOCKWISE
dB DECIBEL
DB DRY BULB TEMPERATURE (°F)
DDC DIRECT DIGITAL CONTROL
DH DUCT HEATER
DP DEW POINT TEMPERATURE (°F)
DX DIRECT EXPANSION
E EXHAUST
EA EXHAUST AIR
EAT ENTERING AIR TEMPERATURE (°F)
EC ELECTRICAL CONTRACTOR
EDR EQUIVALENT DIRECT RADIATION
EER ENERGY EFFICIENCY RATIO
EF EXHAUST FAN
EFF EFFICIENCY
ELEV ELEVATION
ERV ENERGY RECOVERY VENTILATOR
ESP EXTERNAL STATIC PRESSURE
ET EXPANSION TANK
EWT ENTERING WATER TEMPERATURE (°F)
F&T FLOAT & THERMOSTATIC
FA FACE AREA
FC FORWARD CURVED
FC FAN COIL
FP FIRE PROTECTION
FPM FEET PER MINUTE
FT FEET
GA GAUGE OR GAGE
GC GENERAL CONTRACTOR
GEN GENERATOR
GH GRAVITY HOOD
GPD GALLONS PER DAY
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
H HUMIDIFIER
HC HEATING COIL
HG MERCURY
HOA HAND-OFF-AUTOMATIC
HP HORSEPOWER
HR HOUR
HX HEAT EXCHANGER
ABBREVIATIONS
(E) ME-# EXISTING MECHANICAL EQUIPMENT
(D) ME-# DEMOLISHED MECHANICAL EQUIPMENT
T
H
C
P
ADJUSTABLE ROOM TEMPERATURE SENSOR T
COMBO ROOM TEMPERATURE & CO2 SENSORT
A
C
ADJUSTABLE COMBO ROOM TEMP & CO2 SENSORT
C/A
(REL) ME-# RELOCATE MECHANICAL EQUIPMENT
(NL) ME-# NEW LOCATION MECHANICAL EQUIPMENT
DATE:
SHEET:
317 Cruse Ave. Suite 201
Helena, Montana
59601
406.449.2013 www.mosaicarch.com
D A
T E
S T
A M
P a r c h i t e c t u r e - p l a n n i n g - d e s i g n
CITY STAMP
/4
/2
:5 :1
A
M
8.4.2023
M001
MECHANICAL LEGEND & NOTES
26 FORT MISSOULA RD, MISSOULA, MT
REGIONAL FORESTER’S
OFFICE AND BUILDING 26
LARGE CONFERENCE
ROOM RENOVATIONS
C O
N S
T R
U C
T I O
N D
O C
U M
E N
T S
MECH. SHEET INDEX
NUMBER SHEET NAME
M001 MECHANICAL LEGEND & NOTES
M002 MECHANICAL SPECIFICATIONS
M003 MECHANICAL SPECIFICATIONS
M101 MECHANICAL FLOOR PLAN - OFFICE
M103 MECHANICAL FLOOR PLAN - CONFERENCE
INSTALLATION:
A. NEW PIPING, DUCTWORK AND EQUIPMENT TO BE INSTALLED IN
ACCORDANCE WITH THE CURRENTLY ADOPTED INTERNATIONAL
MECHANICAL AND INTERNATIONAL BUILDING CODES.
B. EQUIPMENT SHALL BE INSTALLED LEVEL, PLUMB, AND FIRMLY
ANCHORED IN LOCATIONS INDICATED ON PLAN. OBSERVE
MANUFACTURER'S INSTALLATION INSTRUCTIONS AND RECOGNIZED
INDUSTRY PRACTICES TO ENSURE THAT PRODUCTS SERVE THEIR
INTENDED FUNCTION.
C. INSTALL EQUIPMENT, DUCTWORK, AND PIPING SO AS TO MAINTAIN
CODE REQUIRED CLEARANCES FOR ELECTRICAL AND
TELECOMMUNICATION EQUIPMENT.
D. ELEMENTS PENETRATING BUILDING COMPONENTS (ROOF
ASSEMBLIES, WALL ASSEMBLIES, ETC.) SHALL BE SEALED WEATHER
AND WATER TIGHT. COORDINATE PENETRATIONS WITH GENERAL
CONTRACTOR TO PATCH TO THE SATISFACTION OF THE ARCHITECT
OR ENGINEER.
E. PER IECC 2021 EQUIPMENT MANUFACTURED AFTER 1/1/2023 SHALL
MEET MINIMUM SEER2 RATINGS.
COORDINATION:
A. IT SHALL BE THE RESPONSIBILITY OF THE MECHANICAL
CONTRACTOR TO FIELD COORDINATE THE LOCATION OF
EQUIPMENT, ROUTING OF DUCTWORK, AND ROUTING OF PIPING
WITH OTHER TRADES.
B. IT SHALL BE THE RESPONSIBILITY OF THE MECHANICAL
CONTRACTOR TO REVIEW THE DRAWINGS OF OTHER DISCIPLINES
AND PROVIDE THE NECESSARY LABOR AND MATERIALS REQUIRED
FOR A COMPLETE INSTALLATION.
C. COORDINATE THE INSTALLATION OF GRILLES, REGISTERS AND
DIFFUSERS WITH THE ARCHITECTURAL REFLECTED CEILING PLANS,
THE ELECTRICAL LIGHTING PLANS, AND IF RELEVANT, THE
TELECOMMUNICATION AND FIRE SPRINKLER PLANS.
ELECTRICAL COORDINATION:
A. SEE THE MEP COORDINATION SCHEDULE FOR ELECTRICAL
INFORMATION. COORDINATE WITH OTHER TRADES TO ENSURE
THAT ELECTRICAL DISCONNECTS, MOTOR STARTERS, VARIABLE
FREQUENCY DRIVES, CONTROLS, AND ELECTRICAL ACCESSORIES
ARE FURNISHED AND/OR INSTALLED BY THE APPROPRIATE TRADE.
SITE ELEVATION:
A. EQUIPMENT SHALL BE SELECTED FOR THE PROJECT ELEVATION OF
3,205 FT.
MECH. GENERAL NOTES
GRD REMARKS:
1. SUBMITTAL DATA SHALL INCLUDE N.C., THROW, VELOCITY, AND PRESSURE
DROP AS WELL AS ALL PHYSICAL AND INSTALLATION DATA.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL FITTINGS
AND ACCESSORIES REQUIRED FOR A COMPLETE INSTALLATION.
3. N.C. VALUES IN SCHEDULE ARE VALID FOR SCHEDULE AIRFLOW ONLY AND
REPRESENT A MAXIMUM ACCEPTABLE VALUE. SUBSTITUTE EQUIPMENT
SHALL HAVE N.C. VALUE EQUAL TO OR BELOW THE VALUE SCHEDULE.
ACCESSORY REMARKS:
1. PROVIDE FRAME FOR INSTALLATION IN RELEVANT CEILING TYPE. REFER
TO ARCHITECTURAL RCP FOR CEILING TYPE.
2. PROVIDE MANUAL BALANCING DAMPER AT LOCATIONS WHERE A
SPECIFIED AIR VOLUME IS SHOWN.
GRILLE, REGISTER AND DIFFUSER SCHEDULE
MARK MANUF. MODEL DESCRIPTION NECK SIZE FUNCTION
MAX AIRFLOW
(CFM)
PERFORMANCE DATA AT MAX CFM MOUNTING & FINISH
N.C.
PRESSURE DROP
(IN WC)
THROW AT 50 FPM
(FT)
VELOCITY (FPM) THROW DIRECTION MOUNTING MATERIAL FINISH
(E) PRICE SMCD
MODULAR CORE
DIRECTIONAL
DIFFUSER
6"x6" SUPPLY 50 < 15 0.009 1 200 4 WAY LAY-IN STEEL BY ARCHITECT
S-1 PRICE SMCD
MODULAR CORE
DIRECTIONAL
DIFFUSER
6"x6" SUPPLY 50 < 15 0.009 1 200 4 WAY LAY-IN STEEL BY ARCHITECT
# DATE REVISION
KEY PLAN
N
CONFERENCE
ROOM
OFFICE
26 FORT MISSOULA RD, MISSOULA, MT
BUILDING 26 RENO.
MECHANICAL SPECIFICATIONS
GENERAL
1. THE MECHANICAL CONTRACTOR SHALL INCLUDE ALL ITEMS, ARTICLES, MATERIALS, OPERATIONS AND METHODS LISTED, MENTIONED, OR
SCHEDULED IN THESE SPECIFICATIONS AND THE ACCOMPANYING DRAWINGS. ALL MATERIAL, EQUIPMENT, AND LABOR SHALL BE FURNISHED TOGETHER WITH ALL INCIDENTAL ITEMS REQUIRED BY GOOD PRACTICE TO PROVIDE THE COMPLETE SYSTEMS DESCRIBED.
2. EXAMINE AND REFER TO ALL ARCHITECTURAL, CIVIL, STRUCTURAL, ELECTRICAL, UTILITY, LANDSCAPE AND MECHANICAL DRAWINGS AND SPECIFICATIONS FOR CONSTRUCTION CONDITIONS WHICH MAY AFFECT THE MECHANICAL WORK. INSPECT THE BUILDING SITE AND EXISTING FACILITIES FOR VERIFICATION OF PRESENT CONDITIONS. MAKE PROPER PROVISIONS FOR THESE CONDITIONS IN PERFORMANCE OF THE
WORK AND COST THEREOF.
3. ALL WORK ON THE PROJECT SHALL CONFORM TO ALL ADOPTED CITY, STATE, AND NATIONAL CODES & REGULATIONS. SUCH CODES & REGULATIONS INCLUDE, BUT ARE NOT LIMITED TO, THE IBC, IMC, IECC, UPC, NFPA, NEC, SERVICING UTILITY COMPANIES AND THE AUTHORITY
HAVING JURISDICTION.
4. THE MECHANICAL AND ELECTRICAL CONTRACTORS SHALL BE RESPONSIBLE FOR AND PAY FOR ALL FEES AND PERMITS REQUIRED FOR WORK
UNDER THEIR CONTRACT AND UNDER THEIR SUPERVISION BY SUBCONTRACT.
5. ALL USAGE CONTRACTS BETWEEN THE OWNER AND THE SERVING UTILITIES COMPANY, SUCH AS MEMBERSHIP AND USAGE CHARGES OR FEES, ETC., FOR THE PURPOSE OF OBTAINING THE SERVICES FOR THE UTILITY COMPANY SHALL BE APPLIED FOR AND PAID FOR BY THE
OWNER.
RESPONSIBILITY
1. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION OF A SATISFACTORY AND COMPLETE SYSTEM IN
ACCORDANCE WITH THE INTENT OF THE DRAWING AND SPECIFICATIONS. PROVIDE, AT NO EXTRA COST, ALL INCIDENTAL ITEMS, MATERIALS, ACCESSORIES AND LABOR REQUIRED FOR COMPLETION OF THE WORK EVEN THOUGH THEY ARE NOT SPECIFICALLY MENTIONED OR
INDICATED ON THE DRAWINGS OR IN THE SPECIFICATIONS.
2. THE DRAWINGS DO NOT ATTEMPT TO SHOW COMPLETE DETAILS OF THE BUILDING CONSTRUCTION WHICH AFFECT THE MECHANICAL INSTALLATION; AND REFERENCE IS THEREFORE REQUIRED TO THE ARCHITECTURAL, CIVIL, STRUCTURAL, LANDSCAPE AND ELECTRICAL DRAWINGS AND SPECIFICATIONS AND TO SHOP DRAWINGS OF ALL TRADES FOR ADDITIONAL DETAILS WHICH AFFECT THE INSTALLATION OF
THE WORK COVERED UNDER THIS DIVISION OF THE CONTRACT.
3. LOCATION OF MECHANICAL SYSTEM COMPONENTS SHALL BE CHECKED FOR CONFLICTS WITH OPENINGS, STRUCTURAL MEMBERS AND COMPONENTS OF OTHER SYSTEMS HAVING FIXED LOCATIONS. IN THE EVENT OF ANY CONFLICTS, THE ARCHITECT/ENGINEER SHALL BE CONSULTED AND THEIR DECISION SHALL GOVERN. NECESSARY CHANGES SHALL BE MADE AT THE CONTRACTOR'S EXPENSE.
4. DO NOT INSTALL EQUIPMENT UNTIL COMPLETE SHOP DRAWINGS OF SUCH EQUIPMENT HAVE BEEN APPROVED BY THE ARCHITECT/ENGINEER.
ANY WORK INSTALLED BY THE CONTRACTOR, PRIOR TO APPROVAL OF SHOP DRAWINGS, WILL BE AT THE CONTRACTOR'S RISK.
5. ALL MODIFICATIONS AND CHANGES REQUIRED DUE TO INSTALLATION OF EQUIPMENT OTHER THAN THE EQUIPMENT SCHEDULED AND SPECIFIED SHALL BE MADE AT THE CONTRACTOR'S EXPENSE, THIS INCLUDES WORK BY OTHER TRADES. IF THE INSTALLATION OF EQUIPMENT OTHER THAN THE SCHEDULED AND SPECIFIED EQUIPMENT REQUIRES MODIFICATIONS TO STRUCTURE, ELECTRICAL SYSTEMS, PLUMBING SYSTEMS, FIRE PROTECTION OR FIRE ALARM SYSTEMS, ANY AND ALL CHANGES SHALL BE MADE AT THE MECHANICAL CONTRACTORS
EXPENSE.
6. ALL WORK TO BE PERFORMED SHALL FIRST BE SCHEDULED AND SUBMITTED TO THE OWNER'S REPRESENTATIVE FOR ACCEPTANCE.
7. THE CONTRACTOR SHALL BE CAREFUL NOT TO BLOCK ANY PATHS OF EGRESS WHILE PERFORMING THE WORK SPECIFIED.
8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CLEANUP OF ALL MATERIALS RESULTING FROM HIS/HER WORK. CLEANUP SHALL BE PERFORMED TO THE LEVEL OF ACCEPTANCE OF THE OWNER'S REPRESENTATIVE & THE ENGINEER.
9. THE CONTRACTOR SHALL GUARANTEE THAT ALL WORK EXECUTED UNDER THEIR CONTRACT SHALL BE FREE OF DEFECTS OF MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF SUBSTANTIAL COMPLETION.
INTENT OF DRAWINGS
1. THE DRAWINGS ARE PARTLY DIAGRAMMATIC AND DO NOT NECESSARILY SHOW EXACT LOCATION OF PIPING AND DUCTWORK UNLESS
SPECIFICALLY DIMENSIONED. RISER AND OTHER DIAGRAMS ARE SCHEMATIC AND DO NOT NECESSARILY SHOW THE PHYSICAL ARRANGEMENT OF THE EQUIPMENT. THEY SHALL NOT BE USED FOR OBTAINING LINEAL RUNS OF PIPING OR DUCTWORK, NOR SHALL THEY BE USED FOR SHOP DRAWINGS FOR PIPING AND DUCTWORK FABRICATION OR ORDERING. DISCREPANCIES SHOWN ON DIFFERENT PLANS, OR BETWEEN PLANS AND ACTUAL FIELD CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER FOR RESOLUTION.
MATERIALS AND EQUIPMENT
1. MANUFACTURER'S TRADE NAMES AND CATALOG NUMBERS ARE LISTED TO INDICATE THE QUALITY OF EQUIPMENT OR MATERIALS DESIRED
FOR INSTALLATION. ALTERNATIVE EQUIPMENT OR MATERIALS MAY BE SUBMITTED FOR PRIOR APPROVAL BEFORE BIDDING THE PROJECT. NO
SUBSTITUTIONS WILL BE ALLOWED AFTER BIDDING.
2. WRITTEN PRIOR APPROVAL FOR SUBSTITUTIONS MUST BE SUBMITTED TO AND RECEIVED BY THE ARCHITECT/ENGINEER SEVEN (7) DAYS PRIOR TO BID OPENING. REQUESTS FOR SUBSTITUTION ARE TO BE SUBMITTED SUFFICIENTLY AHEAD OF THE DEADLINE TO GIVE AMPLE TIME FOR EXAMINATION. PRIOR APPROVAL REQUEST FOR SUBSTITUTION MUST INDICATE THE SPECIFIC ITEM OR ITEMS TO BE FURNISHED IN LIEU OF THOSE SCHEDULED, TOGETHER WITH COMPLETE TECHNICAL AND COMPARATIVE DATA ON SCHEDULED ITEMS AND ITEMS PROPOSED FOR
SUBSTITUTION.
3. HIGH ALTITUDE OPERATION: CAPACITY OF ALL EQUIPMENT IS TO BE SIZED AND MANUFACTURED TO PERFORM AT THE ELEVATION OF THE PROJECT SITE. IF NOT SPECIFICALLY INDICATED IN THE EQUIPMENT SCHEDULE OR IN THE SPECIFICATIONS PROVIDE ALL REQUIRED
ACCESSORIES AND EQUIPMENT FOR PROPER OPERATION AT ELEVATION OF THE PROJECT SITE.
4. STORE MATERIALS AND EQUIPMENT INDOORS AT THE JOB SITE OR, IF THIS IS NOT POSSIBLE, STORE ON RAISED PLATFORMS AND PROTECT FROM THE WEATHER BY MEANS OF WATERPROOF COVERS. COVERINGS SHALL PERMIT CIRCULATION OF AIR AROUND THE MATERIALS TO PREVENT CONDENSATION OF MOISTURE. SCREEN OR CAP OPENINGS IN EQUIPMENT TO PREVENT THE ENTRY OF VERMIN.
5. ALL NEW PIPING SHALL BE IDENTIFIED WITH SETON SET MARK PIPE MARKERS, LETTERED TO MATCH EXISTING - IF APPLICABLE - AND MARKED AT A MAXIMUM OF EVERY 25 FT. ALL NEW VALVES SHALL BE IDENTIFIED WITH BRASS OR ALUMINUM VALVE TAGS.
MATERIALS AND EQUIPMENT (CONT.)
6. SEE THE DUCTWORK SCHEDULE AND MECHANICAL PIPING SCHEDULE ON THE DRAWINGS FOR MATERIAL AND INSULATION REQUIREMENTS.
7. COORDINATE THE INSTALLATION OF GRILLES, REGISTERS AND DIFFUSERS WITH THE ARCHITECTURAL REFLECTED CEILING PLANS AND THE
ELECTRICAL LIGHTING PLANS.
8. VERIFY THE LOCATION OF THERMOSTATS AND SENSORS WITH THE ARCHITECT AND ENGINEER PRIOR TO INSTALLATION. INSTALL
THERMOSTATS 48" ABOVE FINISHED FLOOR PER ADA REQUIREMENTS.
9. PROVIDE AND INSTALL SEISMIC BRACING FOR ALL EQUIPMENT, DUCTWORK AND PIPING PER THE REQUIREMENTS OF THE INTERNATIONAL
BUILDING CODE.
10. FLEXIBLE DUCTWORK BETWEEN BRANCH DUCTS AND GRILLES, REGISTERS OR DIFFUSERS SHALL BE LIMITED TO 5FT.
11. INSTALL ACCESSIBLE PLUMBING FIXTURES IN COMPLIANCE WITH ADA REQUIREMENTS. INSULATE ALL EXPOSED PIPING BELOW ADA
ACCESSIBLE FIXTURES.
12. INSTALL FLOOR DRAIN STRAINERS AND CLEANOUT COVERS FLUSH AND LEVEL WITH FINISHED FLOOR.
13. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR FIRE-CAULKING ALL FIRE-RATED AND SMOKE-RATED WALL PENETRATIONS OF
PIPING, DUCTWORK, ETC.
14. PROVIDE ACCESS DOORS TO ALLOW SERVICE AND INSPECTION OF EQUIPMENT, VALVES, DAMPERS AND DEVICES INSTALLED ABOVE NON-
REMOVABLE CEILINGS.
SHOP DRAWINGS AND SUBMITTALS
1. WITHIN 30 DAYS OF AWARDING OF THE CONTRACT, THE MECHANICAL CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AND/OR SUBMITTALS
FOR ALL SCHEDULED EQUIPMENT AND MATERIALS INCLUDED IN THE CONSTRUCTION DOCUMENTS.
2. ALL SHOP DRAWINGS AND SUBMITTALS SHALL BE IN THE FORM OF ELECTRONICALLY TRANSMITTED PDFS. SHOP DRAWINGS AND SUBMITTALS SHALL INCLUDE SHOP DRAWINGS AND LITERATURE SHOWING ITEMS TO BE USED, SIZE, DIMENSIONS, CAPACITY, ROUGH-IN, AND ANY OTHER INFORMATION NECESSARY FOR A COMPLETE REVIEW. MANUFACTURER'S LITERATURE SHOWING MORE THAN ONE ITEM SHALL BE CLEARLY MARKED AS TO WHICH ITEM IS BEING FURNISHED OR IT WILL BE REJECTED AND RETURNED WITHOUT REVIEW.
3. EACH SUBMITTED ITEM MUST BE CLEARLY MARKED WITH THE PROJECT NAME, DATE, BRANCH OF WORK, SUBMITTING PARTY, REVISION NUMBER, AND ASSOCIATED SCHEDULE. SUBMITTALS NOT IDENTIFIED AS DESCRIBED ABOVE WILL BE REJECTED AND RETURNED WITHOUT
REVIEW.
4. PRIOR TO THEIR SUBMISSION, EACH SUBMITTAL SHALL BE THOROUGHLY CHECKED BY THE CONTRACTOR FOR COMPLIANCE WITH THE CONTRACT DOCUMENT REQUIREMENTS. EACH SUBMITTAL SHALL THEN BEAR A STAMP EVIDENCING SUCH CHECKING AND SHALL SHOW CORRECTIONS MADE, IF ANY. SUBMITTALS REQUIRING EXTENSIVE CORRECTIONS SHALL BE REVISED BEFORE SUBMISSION TO THE ENGINEER. EACH SUBMITTAL NOT STAMPED AND SIGNED BY THE CONTRACTOR EVIDENCING SUCH CHECKING WILL BE REJECTED AND
RETURNED WITHOUT REVIEW.
5. REVIEW OF THE SHOP DRAWINGS AND LITERATURE BY THE ENGINEER SHALL NOT RELIEVE THE CONTRACTOR FOR RESPONSIBILITY FOR DEVIATIONS FOR THE DRAWINGS OR SPECIFICATIONS, NOR SHALL IT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR ERRORS IN THE SHOP DRAWINGS OR LITERATURE. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE MATERIALS AND EQUIPMENT WHICH
MEET THE SPECIFICATIONS AND JOB REQUIREMENTS.
REVIEW & SITE INSPECTIONS
1. ALL WORK AND MATERIAL IS SUBJECT TO REVIEW AT ANY TIME BY THE ARCHITECT/ENGINEER OR THEIR REPRESENTATIVE. IF THE
ARCHITECT/ENGINEER OR THEIR REPRESENTATIVE FINDS MATERIAL THAT DOES NOT CONFORM TO THESE SPECIFICATIONS OR THAT IS NOT PROPERLY INSTALLED OR FINISHED, CORRECT THE DEFICIENCIES IN A MANNER SATISFACTORY TO THE ARCHITECT/ENGINEER AT THE
CONTRACTOR'S EXPENSE.
STARTUP, TESTING AND OWNER TRAINING
1. ENGAGE A FACTORY AUTHORIZED REPRESENTATIVE TO CONDUCT AN INSPECTION OF THE INSTALLATION OF THEIR COMPANY'S EQUIPMENT
PRIOR TO START-UP OF ANY EQUIPMENT. THE REPRESENTATIVE SHALL SUBMIT A REPORT IDENTIFYING ANY DEFICIENCIES TO THE ARCHITECT, ENGINEER AND CONSTRUCTION MANAGER. ANY DEFICIENCIES IDENTIFIED SHALL BE ADDRESSED PRIOR TO START-UP. START- UP SHALL BE CONDUCTED BY A FACTORY AUTHORIZED REPRESENTATIVE. STARTUP REPORTS SHALL BE SUBMITTED TO THE ARCHITECT
AND ENGINEER ONCE COMPLETED.
2. NEW AIR AND WATER SYSTEMS SHALL BE BALANCED IN THEIR ENTIRETY TO THE SATISFACTION OF THE ENGINEER IN ACCORDANCE WITH NEBB STANDARDS. EXISTING AIR AND WATER SYSTEM SHALL BE BALANCED AS NOTED ON THE DRAWINGS.
PROJECT CLOSEOUT
1. THE MECHANICAL CONTRACTOR SHALL MAINTAIN AT THE PROJECT SITE, A "RECORD SET OF DRAWINGS" SHOWING FIELD CHANGES, AS-
BUILT ELEVATIONS, UNUSUAL CONDITIONS ENCOUNTERED DURING CONSTRUCTION, AND SUCH OTHER DATA AS REQUIRED TO PROVIDE THE OWNER WITH AN ACCURATE "AS CONSTRUCTED" SET OF RECORD DRAWINGS. THE CONTRACTOR SHALL FURNISH THIS "RECORD SET" TO
THE ENGINEER FOLLOWING THE FINAL INSPECTION OF THE PROJECT.
2. THE MECHANICAL CONTRACTOR SHALL PROVIDE AN "OPERATION AND MAINTENANCE MANUAL" (O&M MANUAL) PRIOR TO THE COMMENCEMENT OF OWNER TRAINING. THE O&M MANUAL SHALL BE PROVIDED IN DIGITAL OR THREE PAPER COPIES (BOUND & LABELED) FORMAT AS REQUESTED BY THE ENGINEER OR OWNER. THE O&M MANUAL SHALL CONSIST OF A TITLE PAGE, TABLE OF CONTENTS, AND MANUAL CONTENTS. THE MANUAL CONTENTS SHALL CONSIST OF PRODUCT DATA INFORMATION, PRODUCT SERVICE/MAINTENANCE MANUAL, AND EXECUTED WARRANTY FOR EACH AND ALL EQUIPMENT AND PRODUCTS INSTALLED UNDER THE SCOPE OF THIS PROJECT.
MECHANICAL PIPE SCHEDULE
SYSTEM ABBREV PIPE MATERIAL INSULATION
CONDENSING UNIT - SUCTION LINE ONLY REF 'ACR' COPPER 1/2" ELASTOMERIC
REFRIGERATION - LIQUID & SUCTION LINES REF 'ACR' COPPER
NOTE:
1. INSULATION THICKNESS IS BASED ON A CONDUCTIVITY NOT EXCEEDING 0.27 BTU • INCH / (HR • FT² • °F)
2. PROVIDE SEISMIC BRACING OF PIPING 2-1/2" AND LARGER OR AS REQUIRED BY LOCAL CODES.
3. PIPE INSULATION MUST HAVE A FLAME SPREAD LESS THAN 25 AND A SMOKE-DEVELOPED INDEX OF NOT MORE THAN 50 WHEN TESTED IN
ACCORDANCE WITH ASTM E84 OR UL723.
4. EXPOSED PLASTIC PIPING IS NOT ALLOWED IN AIR PLENUMS. IF PLASTIC PIPE IS USED, IT MUST BE WRAPPED IN PLENUM RATED PIPE
INSULATION.
5. HYDRONIC WATER PIPING SHALL BE ONE OF THE MATERIALS SPECIFIED AT THE CONTRACTORS OPTION.
6. PIPE CONNECTIONS OF DISSIMILAR METALS SHALL REQUIRE A DIELECTRIC NIPPLE. DIELECTRIC UNIONS ARE NOT ALLOWED.
7. PROVIDE FIBERGLASS ALL SERVICE JACKET (ASJ).
8. ASJ TO BE SEALED AT SEAMS AND EDGES.
9. PROVIDE PVC COATED JACKET ON EXPOSED PIPING.
10. PROVIDE ALUMINUM JACKET WITH UV PROTECTIVE COATING ON OUTDOOR PIPING INSTALLATIONS (POLYGUARD OR APPROVED EQUAL).
11. EXTERIOR WATER PIPING AND PIPING IN UNCONDITIONED SPACES SHALL BE ENCASED IN 3" OF INSULATION.
DUCTWORK SCHEDULE
GENERAL NOTES:
1. DUCTWORK SHALL BE CONSTRUCTED AND INSTALLED PER SMACNA GUIDELINES.
2. RECTANGULAR DUCTWORK SHALL BE GALVANIZED SHEET METAL.
3. RECTANGULAR DUCT ELBOWS SHALL HAVE TURNING VANES.
4. ROUND DUCTWORK SHALL BE GALVANIZED SPIRAL SHEET METAL.
5. DUCTWORK UPSTREAM OF VAV BOXES SHALL BE INSTALLED FOR MEDIUM PRESSURE RATING, 3 IN. W.C.
6. PROVIDE SEISMIC BRACING OF DUCTWORK AS REQUIRED BY LOCAL CODES.
7. SHEET METAL DUCTWORK GAGE SHALL BE SELECTED IN ACCORDANCE WITH SMACNA GUIDELINES.
8. DUCTWORK SHALL BE SEALED IN ACCORDANCE WITH SMACNA AND THE CURRENT EDITION OF THE IECC.
9. DUCT INSULATION MUST HAVE FLAME SPREAD LESS THAN 25 AND SMOKE-DEVELOPED INDEX OF NOT MORE THAN 50 WHEN TESTED IN
ACCORDANCE WITH ASTM E84 OR UL 723.
10. OUTSIDE AIR DUCTWORK INSULATION SHALL HAVE INTEGRAL VAPOR BARRIER IN INSULATION JACKET AND SHALL BE SEALED VAPOR TIGHT.
11. INDOOR EXHAUST DUCTWORK SHALL BE INSULATED FROM THE PENETRATION OF THE BUILDING ENVELOPE TO 10 FT UPSTREAM OF A BACKDRAFT
OF SHUTOFF DAMPER.
12. DUCT LINER SCHEDULED BELOW SHALL NOT BE PROVIDED IF SERVING SURGERY SPACES.
13. VALUES SCHEDULED BELOW ARE A MINIMUM AND SHALL BE SUPERSEDED BY MORE STRIGENT, CURRENTLY ADOPTED ENERGY OR MECHANICAL
CODE REQUIRMENTS.
JACKET:
1. FACTORY APPLIED ALL SERVICE JACKETS (ASJ) SHALL BE FOIL SCRIM KRAFT (FSK). SEAL AT EXPOSED SEAMS/ EDGES/ CORNERS WITH FSK
ADHESIVE TAPE.
2. FIELD APPLIED EXTERIOR ALUMINUM JACKET SHALL BE RATED FOR OUTDOOR USE. (POLYGUARD, ALUMAGUARD, OR APPROVED EQUAL).
1/2" ELASTOMERIC
APPLICATION
INSULATION
TYPE R-VALUE
SUPPLY (SA) MINERAL-FIBER BLANKET R-6
RETURN (RA) NONE - -
EXHAUST (EA) - SEE NOTE 11 - -
OUTSIDE (OA)
SA 5' DOWNSTREAM OF VAV BOX NATURAL-FIBER DUCT LINER - -
FLEXIBLE DUCT - 5' LENGTH MAX INTEGRAL R-6
SA & RA 10' FROM AIR HANDLER NATURAL-FIBER DUCT LINER - -
INDOOR
LOCATION VAPOR
BARRIER
YES
YES
FACTORY
INSTALLED
JACKET TYPE
FSK
FOIL
THICKNESS
1"
1"
INDOOR
INDOOR
INDOOR
NONE
MINERAL-FIBER BOARD
R-12 YES FSK
INDOOR
INDOOR
INDOOR
EXHAUST (EA) - SEE NOTE 11 R-12- -INDOOR MINERAL-FIBER BLANKET YES FSK
DATE:
SHEET:
317 Cruse Ave. Suite 201
Helena, Montana
59601
406.449.2013 www.mosaicarch.com
D A
T E
S T
A M
P a r c h i t e c t u r e - p l a n n i n g - d e s i g n
CITY STAMP
/4
/2
:5 :1
A
M
8.4.2023
M002
MECHANICAL SPECIFICATIONS
26 FORT MISSOULA RD, MISSOULA, MT
REGIONAL FORESTER’S
OFFICE AND BUILDING 26
LARGE CONFERENCE
ROOM RENOVATIONS
C O
N S
T R
U C
T I O
N D
O C
U M
E N
T S
# DATE REVISION
DATE:
SHEET:
317 Cruse Ave. Suite 201
Helena, Montana
59601
406.449.2013 www.mosaicarch.com
D A
T E
S T
A M
P a r c h i t e c t u r e - p l a n n i n g - d e s i g n
CITY STAMP
/4
/2
:5 :1
A
M
8.4.2023
M003
MECHANICAL SPECIFICATIONS
26 FORT MISSOULA RD, MISSOULA, MT
REGIONAL FORESTER’S
OFFICE AND BUILDING 26
LARGE CONFERENCE
ROOM RENOVATIONS
C O
N S
T R
U C
T I O
N D
O C
U M
E N
T S
# DATE REVISION
SECTION 221316 - SANITARY WASTE, VENT, AND CONDENSATE PIPING
PART 1 - GENERAL
1.1 SUMMARY
A. SECTION INCLUDES:
1. PIPE, TUBE, AND FITTINGS.
PART 2 - PRODUCTS
2.1 PERFORMANCE REQUIREMENTS
A. COMPONENTS AND INSTALLATION SHALL BE CAPABLE OF WITHSTANDING THE
FOLLOWING MINIMUM WORKING PRESSURE UNLESS OTHERWISE INDICATED:
1. CONDENSATE PIPING: 10-FOOT HEAD OF WATER.
2. SEISMIC PERFORMANCE: CONDENSATE PIPING AND SUPPORT AND INSTALLATION
SHALL WITHSTAND THE EFFECTS OF EARTHQUAKE MOTIONS DETERMINED
ACCORDING TO ASCE/SEI 7.
B. PIPING MATERIALS
C. PIPING MATERIALS SHALL BEAR LABEL, STAMP, OR OTHER MARKINGS OF SPECIFIED
TESTING AGENCY.
D. COMPLY WITH REQUIREMENTS IN "PIPING SCHEDULE" ARTICLE FOR APPLICATIONS OF
PIPE, TUBE, FITTING MATERIALS, AND JOINING METHODS FOR SPECIFIC SERVICES, SERVICE
LOCATIONS, AND PIPE SIZES.
E. PVC PIPE AND FITTINGS
F. COMPLY WITH NSF 14, "PLASTICS PIPING SYSTEMS COMPONENTS AND RELATED
MATERIALS," FOR PLASTIC PIPING COMPONENTS. INCLUDE MARKING WITH "NSF" FOR
PLASTIC CONDENSATE DRAIN.
G. SOLID-WALL PVC PIPE: ASTM D 1785, PRESSURE PIPE.
H. PVC SOCKET FITTINGS: ASTM D 2466, PRESSURE FITTING PATTERNS AND TO FIT
SCHEDULE 40 PIPE.
I. ADHESIVE PRIMER: ASTM F 656.
J. SOLVENT CEMENT: ASTM D 2564.
PART 3 - EXECUTION
3.1 PIPING INSTALLATION
A. DRAWING PLANS, SCHEMATICS, AND DIAGRAMS INDICATE GENERAL LOCATION AND
ARRANGEMENT OF PIPING SYSTEMS.
1. INDICATED LOCATIONS AND ARRANGEMENTS WERE USED TO SIZE PIPE AND
CALCULATE FRICTION LOSS, EXPANSION, PUMP SIZING, AND OTHER DESIGN
CONSIDERATIONS.
2. INSTALL PIPING AS INDICATED UNLESS DEVIATIONS TO LAYOUT ARE APPROVED ON
COORDINATION DRAWINGS.
3. INSTALL PIPING IN CONCEALED LOCATIONS UNLESS OTHERWISE INDICATED AND
EXCEPT IN EQUIPMENT ROOMS AND SERVICE AREAS.
B. INSTALL PIPING AT RIGHT ANGLES OR PARALLEL TO BUILDING WALLS. DIAGONAL RUNS
ARE PROHIBITED UNLESS SPECIFICALLY INDICATED OTHERWISE.
C. INSTALL PIPING ABOVE ACCESSIBLE CEILINGS TO ALLOW SUFFICIENT SPACE FOR CEILING
PANEL REMOVAL.
D. INSTALL PIPING AT INDICATED SLOPES, NOT LESS THAN 1/8” PER FOOT.
E. INSTALL PIPING FREE OF SAGS AND BENDS.
F. INSTALL FITTINGS FOR CHANGES IN DIRECTION AND BRANCH CONNECTIONS.
G. INSTALL SEISMIC RESTRAINTS ON PIPING.
H. MAKE CHANGES IN DIRECTION FOR CONDENSATE PIPING USING APPROPRIATE FITTINGS
FOR BRANCHES AND BENDS.
1. DO NOT CHANGE DIRECTION OF FLOW MORE THAN 90 DEGREES.
2. USE PROPER SIZE OF STANDARD INCREASERS AND REDUCERS IF PIPES OF
DIFFERENT SIZES ARE CONNECTED.
A. REDUCING SIZE OF CONDENSATE PIPING IN DIRECTION OF FLOW IS
PROHIBITED.
I. INSTALL ABOVEGROUND PVC PIPING ACCORDING TO ASTM D 2665.
J. INSTALL SLEEVES FOR PIPING PENETRATIONS OF WALLS, CEILINGS, AND FLOORS.
1. COMPLY WITH REQUIREMENTS FOR SLEEVES SPECIFIED IN SECTION 220500
"GENERAL PROVISIONS OF PLUMBING AND HVAC."
2. INSTALL ESCUTCHEONS FOR PIPING PENETRATIONS OF WALLS, CEILINGS, AND
FLOORS.
K. JOINT CONSTRUCTION
L. PLASTIC, NON-PRESSURE-PIPING, SOLVENT-CEMENT JOINTS: CLEAN AND DRY JOINING
SURFACES. JOIN PIPE AND FITTINGS ACCORDING TO THE FOLLOWING:
1. COMPLY WITH ASTM F 402 FOR SAFE-HANDLING PRACTICE OF CLEANERS,
PRIMERS, AND SOLVENT CEMENTS.
2. PVC PIPING: JOIN ACCORDING TO ASTM D 2855 AND ASTM D 2665 APPENDIXES.
3.2 HANGER AND SUPPORT INSTALLATION
A. COMPLY WITH REQUIREMENTS FOR SEISMIC-RESTRAINT DEVICES.
B. COMPLY WITH REQUIREMENTS FOR PIPE HANGER AND SUPPORT DEVICES.
1. VERTICAL PIPING: MSS TYPE 8 OR TYPE 42, CLAMPS.
2. INSTALL INDIVIDUAL, STRAIGHT, HORIZONTAL PIPING RUNS:
A. 100 FEET AND LESS: MSS TYPE 1, ADJUSTABLE, SWIVEL HANGERS.
C. SUPPORT HORIZONTAL PIPING AND TUBING WITHIN 12 INCHES OF EACH FITTING, VALVE,
AND COUPLING.
D. SUPPORT VERTICAL PIPING AND TUBING AT BASE AND AT EACH FLOOR.
E. INSTALL HANGERS FOR PVC PIPING WITH THE FOLLOWING MAXIMUM HORIZONTAL
SPACING AND MINIMUM ROD DIAMETERS:
1. NPS LESS THAN 2: 48 INCHES WITH 3/8-INCH ROD.
2. SUPPORT PIPING AND TUBING NOT LISTED ABOVE ACCORDING TO MSS SP-58 AND
MANUFACTURER'S WRITTEN INSTRUCTIONS.
F. CONNECTIONS
G. WHERE INSTALLING PIPING ADJACENT TO EQUIPMENT, ALLOW SPACE FOR SERVICE AND
MAINTENANCE OF EQUIPMENT.
H. IDENTIFICATION
I. IDENTIFY EXPOSED CONDENSATE PIPING.
J. CLEANING AND PROTECTION
K. CLEAN INTERIOR OF PIPING. REMOVE DIRT AND DEBRIS AS WORK PROGRESSES.
L. PROTECT CONDENSATE PIPING DURING REMAINDER OF CONSTRUCTION PERIOD TO
AVOID CLOGGING WITH DIRT AND DEBRIS AND TO PREVENT DAMAGE FROM TRAFFIC AND
CONSTRUCTION WORK.
M. PLACE PLUGS IN ENDS OF UNCOMPLETED PIPING AT END OF DAY AND WHEN WORK
STOPS.
N. REPAIR DAMAGE TO ADJACENT MATERIALS CAUSED BY CONDENSATE PIPING
INSTALLATION.
3.3 PIPING…