This combined synopsis and solicitation requests quotes for a Deputy Regional Forester (DFR) Office Conference Room Remodel project. The scope of work involves remodeling an existing secretary's office area to partition off an additional private office as shown in the plan set. All work to make the two resulting areas fully functional will be included, such as electrical, HVAC, lighting, and matching existing form, frame, and colors. The conference room will be remodeled into a dual-purpose space, with its main function as an open conference room featuring removable furniture. Electrical and communication lines will be installed in tracks in the floor and junction boxes will be removable to facilitate furniture movement and provide a secondary purpose as a hoteling and training area. Data and power will also be installed in a new wall. The NAICS code is 236118 for construction project management services, with a small business size standard of $39.5 million. Quotes are requested with a response deadline as indicated in Section L. The solicitation incorporates FAR provisions and clauses in effect as of FAC 2023-06.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A D E F G H KCB J
PRIVATE
OFFICE
HR
140 SF
CONFERENCE
200 SF
OFFICE
195 SF
OFFICE
195 SF
OPEN
OFFICE
(12 STAFF)
OPEN
OFFICE
(16 STAFF)
ENTRY
HALL
RECEPTION
(2 STAFF)
BREAK
PRIVATE
OFFICE
130 SF
JANITOR
WOMENS
RESTROOM
MENS
RESTROOM
EXECUTIVE
ASSISTANT
(2 STAFF)
REGIONAL
FORESTER
360 SF
DEPUTY
REGIONAL
FORESTER
210 SF
DEPUTY
REGIONAL
FORESTER
210 SF
COFFEE / PRINT
115LARGE
CONFERENCE
TELE/DATA
PRINT / COPY / FAX
CONFERENCE
120 SF
ENTRY
ELEVATOR
A
PORCH
STAIR
PORCH
DOWN DOWN
DOWN DOWN
DOWNDOWN
UP UP
RAMP
DOWN
RAMP
DOWN
RAMP
DOWN
DOWN DOWN
UP
CONFERENCE
UP
(E)
SWR
(N)
FSR
(N)
FSR R R R
R R R R
12"Ø
EXHAUST
12"Ø
EXHAUST
BOILER
VENT
BOILER
VENT
R
R
R
R
R
R
R
R
R
6"Ø 8"Ø
X1
F1 F1
F1
P1
B1
B1 B1E
B1E
B1E B1
B1EB1
B1E B1
B1
B1
B1
B1
B1
B1B1
B1
B1E B1
F1E
B1
B1
B1
B1 D2
D2
D2
D2
D2E
P1P2
P1
D1 D1
P1
D1 D1
P1
D1 D1
D1 D1
P1
D1 D1
P1
D1 D1
P1
D1 D1
P1
D1 D1
D2ED2E
D2E
D2E
D2E
D2E D2
D2
D2
D2
D2
D2 P2 P2
P2P2
P2
P2
B1E
B1
B1
B1D2 D2
D2
D2
D2
D2 D2
D2
D2 D2
D2
D2
D2
D2
P2P2
P2
P2 P2 P2
B1EB1ED2E
P1
P1
D2ED2E
D2E
B1 B1
D2
D2D2
D2
G1
G1
D2
D2
D2
D2
B1
B1
D2
D2
D2ED2D2ED2
E1
E1E E1EE1 E1
E1
D2D2
D2 D2
P2
D2
OC
a a a a a b b b b b b d d c d c c cc cc c c
A8
S1 S1
S1 S1
X1
X1
X1
X1
X1 X1
X1X1
X1
X2
D2
D2E
X1
X2
X1 a a a bb b b b b b b bbb bb b b bb b b b b a a bb b b b a a a a a
O C a a b bb b bb a a aa c c c c c c c c b b b b a b b b b a a a a a d d d a a L1A-1
L1A-1 L1A-1 L1A-1 L1A-1L1A-1
L1A-3 L1A-3
L1A-3
L1A-5
L1A-3
L1A-3 L1A-3
L1A-1
L1A-3
L1A-3 L1A-3 L1A-3 L1A-3 L1A-3 L1A-3 L1A-3 L1A-3
L1A-3
L1A-3L1A-3
L1A-3
L1A-3 L1A-3
L1A-3 L1A-3
L1A-3
L1A-3
L1A-5
L1A-5
L1A-5L1A-5
L1A-5
L1A-5
L1A-5
L1A-5
L1A-5
L1A-5L1A-5 L1A-5
L1A-5
L1A-5
L1A-5
L1A-5
L1A-5L1A-5
L1A-5
L1A-5
L1A-5 L1A-5
L1A-5L1A-5L1A-5
L1A-5
L1A-5
L1A-5
L1A-5
L1A-5
L1A-5
L1A-5
L1A-5 L1A-5
L1A-3
L1A-7 L1A-7 L1A-7
L1A-7
L1A-7
L1A-7
L1A-9
L1A-7 L1A-7
L1A-7 L1A-7
L1A-7
L1A-7
L1A-7L1A-7
L1A-7
L1A-7
L1A-7
L1A-7
L1A-7
L1A-7
L1A-7
L1A-7
L1A-7
L1A-7
L1A-7 L1A-7
L1A-7
L1A-7
L1A-7 L1A-7
L1A-7L1A-7
L1A-9
L1A-9
L1A-9
L1A-9 L1A-9
L1A-9
L1A-9 L1A-9
L1A-9
L1A-9 L1A-9
L1A-9
L1A-9
L1A-9L1A-9
L1A-9
L1A-9
L1A-9
L1A-9
L1A-9L1A-9L1A-9
L1A-9
L1A-9
L1A-11 L1A-11 L1A-11
L1A-11
L1A-11
L1A-11
L1A-11
L1A-11 L1A-11L1A-11
L1A-11
L1A-11L1A-11
L1A-11
L1A-11
L1A-11
L1A-11
L1A-11 L1A-11 L1A-11
L1A-11
L1A-11 L1A-11 L1A-11 L1A-11
L1A-11
L1A-11
L1A-11
L1A-11L1A-11
L1A-11
L1A-11
L1A-11 L1A-11
L1A-11
L1A-9 e e e e a e
X1 L1A-9
1-HR FIRE RATING
1-HR FIRE RATING
1-HR FIRE RATING1
1-HR FIRE RATING 1
1-HR FIRE RATING 1
D2 bL1A-9
D2 L1A-5
D2
L1A-5
D2 L1A-5
P2 a
L1A-5
D2
D2 b b L1A-5
L1A-5
E2E L1A-1
E2E L1A-1
E2E L1A-1
E2E L1A-1
E2E L1A-1
E2E L1A-1
E2E
L1A-1
L1A-1
E2E
L1A-1
E2E
L1A-1
E2E L1A-1
L1A-3
E2E L1A-1
E2E L1A-1
D2ED2
L1A-3 L1A-3
D2 L1A-3
D2ED2
bb
L1A-3 L1A-3
D2 b
L1A-3
HANDRAIL LIGHTING3
L1A-1
D2
P2
D2
D2
D2
D2 a bb b b
L1A-5 L1A-5
L1A-5
L1A-5L1A-5
UC L1A-9
UC L1A-7
UC
L1A-7
UCUC
L1A-5 b b
FI
R
ST
F
LO
O
R L
IG
H
T
IN
G P
LA
N
USFS BUILDING 26 - FIRST FLOOR LIGHTING PLAN16
E2.2 : E2.2 1/8" = 1'-0"
NORTH
E7.1
1. CUT EXISTING PLASTER AS NEEDED TO INSTALL ALL P1, D1, AND D2. FLOOR
JOISTS MAY NEED TO BE DRILLED TO PROVIDE A CLEAR PATH. MC CABLE IS
ACCEPTABLE TO FISH THROUGH THE CEILING SPACE.
2. IT IS ABSOLUTELY NECESSARY FOR ALL TRADES INVOLVED TO COORDINATE
WITH EACH OTHER AND VERIFY THAT THERE ARE NO CONFLICTS IN LOCATION
OF DUCTS, CONDUITS, DIFFUSERS, BOXES AND OTHER ITEMS THROUGHOUT
THIS PROJECT BEFORE FINAL PLACEMENT OF MATERIALS.
3. ALL DIMENSIONS AND EXACT UNIT LOCATIONS ARE TO BE FIELD VERIFIED.
THESE DRAWINGS REPRESENT SCHEMATIC SYSTEMS.
4. COORDINATE AVAILABLE SPACE FOR EQUIPMENT AND PIPING SYSTEMS WITH
OTHER TRADES. REFER TO ARCHITECTURAL, STRUCTURAL, PLUMBING, AND
ELECTRICAL DRAWINGS AND FIRE PROTECTION SHOP DRAWINGS FOR
ADDITIONAL DETAILS NECESSARY FOR COORDINATION.
5. COORDINATE ALL CONCRETE PENETRATIONS WITH STRUCTURAL DRAWINGS TO
VERIFY HOW AND WHERE CONCRETE CAN BE CUT.
6. ALL EXTERIOR LIGHTING CIRCUITED VIA AUTOMATIC TIMER. SEE DETAIL6, SHEET
E9.2.
7. ALL WALL-MOUNT EXTERIOR LIGHTING SHALL BE INSTALLED ON FLUSH-MOUNT
JBOX. CONTRACTOR SHALL SAW-CUT EXTERIOR WALL CEMENT, TO
FLUSH-MOUNT JBOX. PATCH/PAINT TO MATCH EXISTING FINISH.
KEY NOTES:
1. ALL MEANS AND MATERIALS FOR WORK ON THIS WALL SECTION
SHALL MEET 1-HR FIRE RATING REQUIREMENTS.
2. RUN CONDUIT BETWEEN JOISTS FLUSH WITH TOP OF
STRUCTURE, ROUTE CONDUIT OUT OF EYE SIGHT WHERE EVER
POSSIBLE. TYPICAL FOR ALL TYPE E2E.
3. HANDRAIL LIGHTING (ALT. BID #2): PROVIDE HANDRAIL LIGHTING
SYSTEM, INCLUDING: 24V POWER SUPPLIES IN NEMA 3R
ENCLOSURE MOUNTED UNDER WALKWAY NEAR WEST END OF
NORTH HANDRAIL, CIRCUITED FROM POWER SUPPLIES TO
2-SETS OF (5) LIGHT RAILS, PER MANUFACTURER'S
REQUIREMENTS. DESIGN BASED ON WAGNER ARCHITECTURAL
SYSTEMS LUMIRAIL PRODUCT LINE. VERIFY EXACT
REQUIREMENTS WITH MANUFACTURER, PRIOR TO ROUGH-IN.
4. SWITCH FOR FIRST AND SECOND FLOOR STAIR/ENTRY. SWITCH
"a" FOR PENDANTS AND "b" FOR CANS LIGHTS.
5. LOW CEILING MOUNT EXIT SIGN TO THE SIDE OF THE DOOR AS
NECESSARY.
BU
IL
D
IN
G
P H
A
SE
SO
U
T H
W
IN
G R
EN
O
V A
T
IO
N
U S
FO
R
ES
T
S
ER
V
IC
E, N
O R
T H
ER
N
R
EG
IO
N
R
EG
IO
N A
L O
FF
IC
E www.aearchitects.com
O W
N E
R
ISSUE DATE
REVISIONS
P R
O
JE
C T
D R
A W
IN
G
PROJECT No 13104.00 7.14.14
6 0 8 N O R T H 2 9 T H B I L L I N G S, M T 59101
PH 4 0 6 . 2 4 8 . 2 6 3 3
FAX 4 0 6 . 2 4 8 . 2 4 2 7
2 2 2 N O R T H H I G G I N S M I S S O U L A, M T 59802
PH 4 0 6 . 7 2 1 . 5 6 4 3
FAX 4 0 6 . 7 2 1 . 1 8 8 7
ARCHITII ECTSP
C
GENERAL NOTES:
2014 MORRISON-MAIERLE, INC.
28342 PE
BLOOMFIELD
ARIAN C.
A S
NO
P
ISSEF
O
R
IGE
R
NOM
L
E E
R
ENG
I N
DERET
ANAT