3. Bldg. 7 & 9 Drawings-Complete.pdf
PDF 8 MB Posted
- Attached to
- Building 7 & 9 Steam Meter Replacements, Ames, IA Federal contract opportunity
- Solicitation number
- 12505B22R0028
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Bldg 9 Entry-Exit Routes.pdf | ||
| 12505B22R0028 - Amendment 01.pdf | ||
| Site visit sign-in sheet 8-17-22.pdf | ||
| 12505B22R0028 - Questions and Answers.pdf | ||
| 1. 12505B22R0028 - Steam Meter Replacements.pdf | ||
| 7. Past Performance Questionnaire.pdf | ||
| 4. Material Submittal Form (002).pdf | ||
| 5. ARS-371.pdf | ||
| 8. Wage Determination.pdf | ||
| 2. Statement of Work Building 7 and 8 Steam Meter Replacements_7.29.22.pdf | ||
| 6. ARS-372.pdf |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Location Coordinator:Contracting Officer Rep.:Contracting Officer:Engineering Project Manager:
Task
Order #:
Drawing Title:PROJECT TITLE:
FEU Project #:
Drawing Number:
Agricultural Research Service U.S. Department of Agriculture
NCAH
1920 Dayton Avenue Ames, Iowa 50010
Revision:
Client:
Sheet: Of
Designer:
Date:
Date:
Page # Description
UNITED STATES DEPARTMENT OF AGRICULTURE
AGRICULTURE RESEARCH SERVICE
NATIONAL CENTERS FOR ANIMAL HEALTH
Building 7
Building 9
Ben A'Hearn TBD Tommy Walker
Building 7 & 9 Steam Meter
Replacements
Title Page
Tommy Walker
22009 USDA 1 5
Building 7 & 9 Steam Meter Replacement
Title Page
Specs-Dimensions
Bldg. 7 Floor Plan
Bldg. 9 Floor Plan
Detail
FOR BID
Drawing Title:
Drawing Number:
Sheet: Of
Design Specifications:
1. Design steam flow rates shall be: 0 lbs/hr minimum; 10,000 lbs/hr normal; and 23,000 lbs/hr maximum. Prowirl D200 maximum is 1,374 lbs/min. Minimum @ 0mA. Maximum # 20mA.
2. Steam is 125# saturated.
3. Line rated end connecting flanges are existing. Meter shall fit within dimensions given.
4. Steam meter is not in hazardous location.
5. Output signal shall be 4-20mA or BACnet.
6. Meter display shall be remote mounted between 10'-20' from meter body.
Steam meter specifications based on the "Endress + Hauser Prowirl D200, 7D2C1F, DN1550 6".
Product Description :
Prowirl D 200, 7D2C1F, DN150 6"
Order Code :
7D2C1F-AACCJCDCAAAASKA1
Disclaimer:
Every reasonable effort has been made to ensure the accuracy of the information contained in this document. Endress+Hauser does not give any guarantee, express or implied, with respect to the accuracy, the completeness or the technical or commercial usefulness of this document.
Endress+Hauser may modify or replace this document at any time.
© 07.12.2021 Endress+Hauser www.addresses.endress.com
People for Process Automation
First Angle Projection XX.X [x.xx] = mm [inch]
94.30[3.71]
160.56[6.32]
Cl.150 RF Sch.40, ASME B16.5
DN150 6"
GT20 dual compartment,alu,coated,remote
No option
5.
[8
.5 0] ø156.75[6.17]
65.00[2.56]
9.
[1
2.
8.
[4
.2 7] ø
.9
0[ 8.
6.
[4
.5 7]
132.26[5.21]
107.00[4.21]
163.00[6.42]
5.
[5
.7 3]
Thread NPT1/2
Non-hazardous area
80.00[3.15]
.0
0[ 2.
.0
0[ 3.
Existing installed meter width between flanges is approximately 3" with gaskets. Contractor to verify.
Specs-Dimensions
2 5
Sheet: Of
3" Measurement is approximate.
Contractor to verify.
Bldg. 7 Floor Plan
3 5
Sheet: Of
0' -3
/4
Measurement is approximate.
Contractor to verify.
Bldg. 9 Floor Plan
4 5
Sheet: Of
Detail
5 5
Remote display
Steam Meter
Liquid tight flexible tubing. Less than 6' length.
EMT
Building 7 Meter Building 9 Meter
| Page-1 - Title Page |
| Page-2 - Specs-Dimensions |
| Page-3 - Bldg. 7 Floor Plan |
| Page-4 - Bldg. 9 Floor Plan |
| Page-5 - Detail |
File details come from the government source that posted it. Updated .