3. Bldg. 7 & 9 Drawings-Complete.pdf

PDF 8 MB Posted

Attached to
Building 7 & 9 Steam Meter Replacements, Ames, IA Federal contract opportunity
Solicitation number
12505B22R0028
Issued by
Department of Agriculture Agricultural Research Service Field Research Implementation and Information Delivery Midwest Area

View the file

Other files for this federal contract opportunity

Other files attached to Building 7 & 9 Steam Meter Replacements, Ames, IA, newest first.
File Type Posted
Bldg 9 Entry-Exit Routes.pdf PDF
12505B22R0028 - Amendment 01.pdf PDF
Site visit sign-in sheet 8-17-22.pdf PDF
12505B22R0028 - Questions and Answers.pdf PDF
1. 12505B22R0028 - Steam Meter Replacements.pdf PDF
7. Past Performance Questionnaire.pdf PDF
4. Material Submittal Form (002).pdf PDF
5. ARS-371.pdf PDF
8. Wage Determination.pdf PDF
2. Statement of Work Building 7 and 8 Steam Meter Replacements_7.29.22.pdf PDF
6. ARS-372.pdf PDF
Show all 11

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Location Coordinator:Contracting Officer Rep.:Contracting Officer:Engineering Project Manager:

Task

Order #:

Drawing Title:PROJECT TITLE:

FEU Project #:

Drawing Number:

Agricultural Research Service U.S. Department of Agriculture

NCAH

1920 Dayton Avenue Ames, Iowa 50010

Revision:

Client:

Sheet: Of

Designer:

Date:

Date:

Page # Description

UNITED STATES DEPARTMENT OF AGRICULTURE

AGRICULTURE RESEARCH SERVICE

NATIONAL CENTERS FOR ANIMAL HEALTH

Building 7

Building 9

Ben A'Hearn TBD Tommy Walker

Building 7 & 9 Steam Meter

Replacements

Title Page

Tommy Walker

22009 USDA 1 5

Building 7 & 9 Steam Meter Replacement

Title Page

Specs-Dimensions

Bldg. 7 Floor Plan

Bldg. 9 Floor Plan

Detail

FOR BID

Drawing Title:

Drawing Number:

Sheet: Of

Design Specifications:

1. Design steam flow rates shall be: 0 lbs/hr minimum; 10,000 lbs/hr normal; and 23,000 lbs/hr maximum. Prowirl D200 maximum is 1,374 lbs/min. Minimum @ 0mA. Maximum # 20mA.

2. Steam is 125# saturated.

3. Line rated end connecting flanges are existing. Meter shall fit within dimensions given.

4. Steam meter is not in hazardous location.

5. Output signal shall be 4-20mA or BACnet.

6. Meter display shall be remote mounted between 10'-20' from meter body.

Steam meter specifications based on the "Endress + Hauser Prowirl D200, 7D2C1F, DN1550 6".

Product Description :

Prowirl D 200, 7D2C1F, DN150 6"

Order Code :

7D2C1F-AACCJCDCAAAASKA1

Disclaimer:

Every reasonable effort has been made to ensure the accuracy of the information contained in this document. Endress+Hauser does not give any guarantee, express or implied, with respect to the accuracy, the completeness or the technical or commercial usefulness of this document.

Endress+Hauser may modify or replace this document at any time.

© 07.12.2021 Endress+Hauser www.addresses.endress.com

People for Process Automation

First Angle Projection XX.X [x.xx] = mm [inch]

94.30[3.71]

160.56[6.32]

Cl.150 RF Sch.40, ASME B16.5

DN150 6"

GT20 dual compartment,alu,coated,remote

No option

5.

[8

.5 0] ø156.75[6.17]

65.00[2.56]

9.

[1

2.

8.

[4

.2 7] ø

.9

0[ 8.

6.

[4

.5 7]

132.26[5.21]

107.00[4.21]

163.00[6.42]

5.

[5

.7 3]

Thread NPT1/2

Non-hazardous area

80.00[3.15]

.0

0[ 2.

.0

0[ 3.

Existing installed meter width between flanges is approximately 3" with gaskets. Contractor to verify.

Specs-Dimensions

2 5

Sheet: Of

3" Measurement is approximate.

Contractor to verify.

Bldg. 7 Floor Plan

3 5

Sheet: Of

0' -3

/4

Measurement is approximate.

Contractor to verify.

Bldg. 9 Floor Plan

4 5

Sheet: Of

Detail

5 5

Remote display

Steam Meter

Liquid tight flexible tubing. Less than 6' length.

EMT

Building 7 Meter Building 9 Meter

Page-1 - Title Page
Page-2 - Specs-Dimensions
Page-3 - Bldg. 7 Floor Plan
Page-4 - Bldg. 9 Floor Plan
Page-5 - Detail

File details come from the government source that posted it. Updated .